LEM电流电压传感器说明书

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

LEM

Page 1/3

LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.

051123/6

Current Transducer LTSR 25-NP

For the electronic measurement of currents : DC, AC, pulsed, mixed,with a galvanic isolation between the primary circuit (high power)and the secondary circuit (electronic circuit).

Electrical data

I PN Primary nominal r.m.s. current 25At

I P

Primary current, measuring range 0 .. ± 80 1)

At V OUT Analog output voltage @I P

2.5 ± (0.625·I P /I PN )V I P = 0

2.5 2)V V REF Voltage reference (internal reference), refout mode

2.5 3)

V

Voltage reference (external reference), refin mode

1.9 ..

2.7

4)

V N

S Number of secondary turns (± 0.1 %)2000R L Load resistance

≥ 2k ΩC L Max. capacitive loading

500pF R IM

Internal measuring resistance (± 0.5 %)50ΩTCR IM Thermal drift of R IM

< 50ppm/K V C Supply voltage (± 5 %)

5V I C

Current consumption @ V C = 5 V Typ

28 + I S 5)+ (V OUT /R L )mA

Accuracy - Dynamic performance data

X

Accuracy @ I PN , T A = 25°C

± 0.2%Accuracy with R IM @ I PN , T A = 25°C ± 0.7%ε

L

Linearity error

< 0.1

%

Max

TCV OUT Thermal drift of V OUT / V REF @ I P = 0- 40°C .. + 85°C 37.5 ppm/K

TC εG Thermal drift of the gain - 40°C .. + 85°C 50 6)ppm/K V OM

Residual voltage @ I P = 0, a fter an overload of 3 x I PN ± 0.5mV

5 x I PN ± 2.0mV 10 x I PN ± 2.0mV

TCV REF Thermal drift of internal V REF @ I P = 0 - 10°C .. + 85°C 50ppm/K

- 40°C .. - 10°C 100ppm/K

t ra Reaction time @ 10 % of I PN < 100ns t r

Response time @ 90 % of I PN < 400ns di/dt di/dt accurately followed > 60A/µs f

Frequency bandwidth (0 .. - 0.5 dB)DC .. 100kHz

(- 0.5 .. 1 dB)DC .. 200kHz General data

T A Ambient operating temperature

- 40 .. + 85°C T S Ambient storage temperature - 40 .. + 100°C m

Mass

10

g

Standards

EN 50178 : 1997I EC 60950-1 : 2001

Notes :see overleaf.

Features

•Closed loop (compensated) multi-range current transducer using the Hall effect

•Unipolar voltage supply

•Insulated plastic case recognized according to UL 94-V0

•Compact design for PCB mounting •Incorporated measuring resistance •Extended measuring range •Access to the internal voltage reference

Possibility to feed the transducer reference from external supply.

Advantages

•Excellent accuracy •Very good linearity

•Very low temperature drift •Optimized response time •Wide frequency bandwidth •No insertion losses

High immunity to external interference

•Current overload capability.

Applications

•AC variable speed drives and servo motor drives

•Static converters for DC motor drives •Battery supplied applications

•Uninterruptible Power Supplies (UPS)•Switched Mode Power Supplies (SMPS)•

Power supplies for welding applications.

I PN = 25 At

Copyright protected.

Application Domain

•Industrial.