P9000系列高性能压力传感器

合集下载

蒙德IMS-P3系列使用说明书

蒙德IMS-P3系列使用说明书

30mm以上
50/60H
(W)
500
500
800
800
1000 1000 1000 2000 2000 3000 3000
※制动电阻(必配)
(Ω)
24
24
16
16
12
12
12
6
6
4
4
※滤波器(选配) (A)
20
20
35
35
50
50
80
80
100
150
200
旋转变压器信号线缆(必配)
LE17-***:***代表线缆长度,单位为 cm。 如:LE17-300 代表线缆长度为 3m
驱动器的保压电流为: I(A)=Tmax(Nm)/ Kt(Nm/A) 根据该数值对应表 1.2 中“最大保压电流(A)连续 60s”项可得到所需驱动器型号以及驱动器周边零部件 型号。
6
外形安装尺寸
以下为 P3 驱动器的外形安装尺寸。
H H1
H1 H
W1 W
D
图 1.5 外形安装尺寸 对应 45P5E~4015E
P3 驱动器参数内容及说明 ......................................15
参数组别 参数内容及说明
15 15
P3 驱动器调试过程 ............................................20
基本调试 性能调整
20 21
P3 驱动器报警说明 ............................................26
表 1.4 安装尺寸
型号 IMS-P3-*****-05E0 45P5E 47P5E 4011E 4015E 4018E 4022

RVP900

RVP900
• Dual Polarization, Wide Dynamic Range, and Pulse Compression ready.
• Open Linux PC platform
RVP900 provides a full suite of weather radar signal processing functionality to support implementing a new weather radar or upgrading an existing system to the latest signal processing technology.
• Ethernet interface allowing RVP900 to be PC independent.
• Independent and parallel FIR filtering allowing dual pulse width and dual frequency strategies on each receive channel
Phase Stability
Klystron Magnetron (for 1.0 microsecond pulse)
Better than 0.1° Better than 0.5°
RVP901 IFDR I/O
Analog input
AFC output
Data output through Ethernet RS-422 RVP901 to RVP902 link
RVP901 IF Digital Receiver
RVP901 IF Digital Receiver (IFDR) provides receive, transmit, and IF detector functionality in a single, compact network-attached FGPA-based product able to perform tens of billions of multiply accumulate cycles per second.

艾默生 Micro Motion (高准) 技术概述和规格汇总 产品说明书

艾默生  Micro Motion (高准) 技术概述和规格汇总 产品说明书

产品样本PS-002538, Rev AA2023 年 2 月Micro Motion™ (高准) 技术概述和规格汇总2023 年 2 月高准产品艾默生世界领先的高准科里奥利流量和密度测量设备已为高级测量技术设立了标准。

高准做到了为应对多样化工艺挑战提供优异测量解决方案。

高准优势先进的技术高准致力于技术创新,为应对复杂测量问题提供高性能的解决方案。

广泛的产品范围高准提供种类广泛的流量和密度测量设备,可满足众多过程、应用或流体测量需要。

多种接液材料、管路尺寸以及宽范围的输出选项,以提供出色的系统集成。

可观比拟的价值您将能够通过来自于全球超过 100 万台流量计的在线应用经验以及 40 多年的流量和密度测量经验支持的专家级现场和技术应用服务与支持受益无穷。

高准科里奥利流量和密度仪表2023 年 2 月产品样本32023 年 2 月流量和密度仪表规格表 1: 应用类型连续控制某些型号支持表 2: 测量精度液体质量流量±0.05%±0.05%±0.1%±0.2%±0.05%±0.50%±0.1%±0.1%±0.5%4Micro Motion (高准) 技术概述和规格汇总表 3: 功能表4: 接液材料表 5: 适于标准口径2023 年 2 月产品样本52023 年 2 月高准变送器和控制器6Micro Motion (高准) 技术概述和规格汇总2023 年 2 月产品样本72023 年 2 月变送器和控制器规格输出变量基于浓度的产品流量。

例如,在溶解糖溶液中,仅测量糖的流量;在纯油应用中,仅测量水或油。

现场显示8Micro Motion (高准) 技术概述和规格汇总2023 年 2 月电源输出®产品样本92023 年 2 月以太网输出通过使用高准 EtherNet/IP 模块。

(2)Ethernet/IP 模块不支持 1500 快速灌装以及 3500 和 3700 配料。

示波器探头和附件(是德科技InfiniiVision 系列)

示波器探头和附件(是德科技InfiniiVision 系列)
目录
引言���������������������������������������������������������������������������������������������������������������������������������������������������������������� 2 探头兼容性表������������������������������������������������������������������������������������������������������������������������������������������������� 3 无源探头�������������������������������������������������������������������������������������������������������������������������������������������������������� 5 极限温度无源探头����������������������������������������������������������������������������������������������������������������������������������������� 9 高压无源探头����������������������������������������������������������������������������������������������������������������������������������������������� 10 InfiniiMax 有源探头和附件��������������������������������������������������������������������������������������������������������������������������� 11 InfiniiMode 有源探头和附件������������������������������������������������������������������������������������������������������������������������ 13 通用差分有源探头——DP0001A 高压差分探头������������������������������������������������������������������������������������������ 15 高压差分有源探头��������������������������������������������������������������������������������������������������������������������������������������� 17 单端有源探头����������������������������������������������������������������������������������������������������������������������������������������������� 21 混合信号示波器逻辑探头����������������������������������������������������������������������������������������������������������������������������23 钳形电流探头����������������������������������������������������������������������������������������������������������������������������������������������� 2பைடு நூலகம் N7040A/41A/42A 罗氏线圈交流电流探头��������������������������������������������������������������������������������������������������29 高灵敏度电流探头���������������������������������������������������������������������������������������������������������������������������������������30 楔形探头适配器������������������������������������������������������������������������������������������������������������������������������������������� 32 其他附件� ������������������������������������������������������������������������������������������������������������������������������������������������������33 T2A 探头接口适配器�����������������������������������������������������������������������������������������������������������������������������������35 推荐用于中/低速总线测量的探头���������������������������������������������������������������������������������������������������������������36

美卓 ValvGuard 9000H说明书

美卓 ValvGuard 9000H说明书
9 工具 ............................................................... 25 10 订购配件 ........................................................ 25 11 图纸和零件明细表 ......................................... 26
1
VG9000H VALVGUARD

采用 HART 通信协议的智能安全电磁阀
1.1 概述
本手册包含美卓 Neles ValvGuard VG9000H 的安装、维 护和操作说明。VG9000H 可用于回转或线性阀门所使用 的气缸或隔膜式气动执行机构。
注意:
在特定应用条件下选择使用 ValvGuard 需周密考虑很多 不同的因素。由于产品的特性,本手册不可能涵盖阀门 安装、使用或维修时所发生的所有状况。
2 运输、接收和贮存 ............................................8 3 安装 .................................................................8
3.1 概述 ....................................................... 8 3.2 安装于带有 VDI/VDE 安装面的美卓
Neles ValvGuard ™ VG9000H
版本:2.0
安装、维护和操作手册
7 VG9H 70 zh • 4/2015
2
目录
1 VG9000H VALVGUARD ..................................3 1.1 概述 ....................................................... 3 1.2 技术说明 ................................................ 3 1.3 系统架构 ................................................ 4 1.4 标识 4 1.5 技术参数 ................................................ 4 1.6 废弃阀门的再回收和处理 ....................... 7 1.7 安全须知 7

JUMO MIDAS C08 OEM 压力传感器 数据表 401002说明书

JUMO MIDAS C08 OEM 压力传感器 数据表 401002说明书

Page 1/10Data Sheet 401002JUMO MIDAS C08OEM Pressure Transmitter – BasicApplications•compressors•machinery and plant engineering •industrial pneumatics •commercial vehicles •building technologyBrief descriptionThis pressure transmitter is used as the core product for the MIDAS range for applications re-quiring reliable implementation of measuring tasks with long-term stability and excellent price-performance ratio. The MIDAS range provides solutions for all applications on the basis of this core product.The innovative and patented sensor design of the specifically developed ceramic sensor pro-vides excellent long-term stability of <0.2%. It can be used for recording relative pressures of 1.6bar to 60bar in gaseous or liquid media.Type 401002 with QUICKONType 401002 with M12×1 connectorCustomer benefits•process-reliableThrough constructive measures, the pressure transmitter achieves excellent vibration resis-tance and enables application under high vibration load, as occurs in commercial vehicles for example. The throughput through the fully automatic measuring and calibration devices,the diagnostic function of the switching circuit, and the full final inspection complete the high standard of quality.•economicThe QUICKON quick-clamp technology enables quicker and safer installation. The connec-tion is even guaranteed with any temperature fluctuations that may occur thanks to the spring contacts. This electrical connection means that installation times can be shortened and as a result, costs are reduced by 60 % compared to conventional connection options.•versatileThe universal application is reflected by the wide choice of measuring ranges, process con-nections, and electrical connections.Special features•long-term stability <0.2%•new level of quality for the OEM sector •60% quicker device installation with the QUICKON quick-clamp technology •temperature compensation range in-creased by 50 % to -20°C to +100°C • 2.5 times more vibration resistance than the industry standard •made in GermanyApprovals/approval marks (see "Technical data")Page 2/10Data Sheet 401002Technical dataGeneral InformationMeasuring range and accuracyReference conditions DIN 16086 and DIN EN 60770SensorMeasuring principle Thick film on ceramic bodies (piezo-resistive)Admissible load changes >10million, 0to 100% measuring range Mounting position AnyCalibration positionDevice upright, process connection at the bottom Measuring rangeLinearity a Accuracy at Long-term stability b Overload capacity c Burst pressure 20°C d -10to +85°C e -20to +100°C e % MSP f% MSP % MSP % MSP % MSP per year bar bar 0to 1.6bar relative pressure 0.250.50.6510.26120to 2.5bar relative pressure 6120to 4bar relative pressure 0.350.512250to 6bar relative pressure 12250to 10bar relative pressure 20380to 16bar relative pressure 50750to 25bar relative pressure 50750to 40bar relative pressure 1202000to 60bar relative pressure 120200-1to +0.6bar relative pressure 0.50.65612-1to +1.5bar relative pressure 612-1to +3bar relative pressure 0.350.51225-1to +5bar relative pressure 1225-1to +9bar relative pressure 2038-1to +15bar relative pressure 5075-1to +24bar relative pressure5075a Linearity according to limit point settingb Reference conditions EN 61298-1c All pressure transmitters are vacuum-proof.d Includes: linearity, hysteresis, repeatability, deviation of measuring range initial value and measuring range end valuee Includes: linearity, hysteresis, repeatability, deviation of measuring range initial value and measuring range end value, thermal effect on mea-suring range start and measuring span fMSP = Measuring spanPage 3/10Data Sheet 401002OutputMechanical featuresAnalog output a Current 4to 20mA, two-wire (output 405)VoltageDC 0.5to 4.5V, three-wire,ratiometric 10to 90% of the voltage supply (output 412)DC 0to 10V, three-wire (output 415)DC 1to 5V, three-wire (output 418)DC 1to 6V, three-wire (output 420)Step response T 90≤2msBurden CurrentR L ≤(U B -8V)÷0.02A (Ω) at 4to 20mA, two-wire (output 405)Voltage(burden connected to "0V/S-")R L ≥5k Ω at DC 0.5to 4.5V, three-wire (output 412)R L ≥10k Ω at DC 0to 10V, three-wire (output 415)R L ≥10k Ω at DC 1to 5V, three-wire (output 418)R L ≥10k Ω at DC 1to 6V, three-wire (output 420)aFurther outputs are available upon request.MaterialProcess connection Stainless steel 304for push-in fitting(process connection 383)Brass, nickel-plated Seal 600 (internal a )EPDM Seal 601 (internal a)FKM, standard Seal 602 (internal a )CR Seal 604 (internal a )FFKM Seal 609 (internal a )NBR for G 1/4 (process connection 521)(external a )FKMSensor Ceramic Al 2O 3 96%HousingStainless steel 304Attached cable(electrical connection 11)PBT-GF30, PVC QUICKON(electrical connection 23)PBT-GF30Round plug M12×1 (electrical connection 36)PBT-GF30, stainless steel 303L Bayonet connector(electrical connection 53)PBT-GF30Cable socket(electrical connection 61)PBT-GF30, PA, siliconeWeight70g with G 1/4 (process connection 502)aEnsure the medium durability of the seal material!Page 4/10Data Sheet 401002Environmental influencesMedium temperature for electrical connection Attached cable -20to +125°C Round plug M12×1-20to +125°C Bayonet connector -20to +125°C Cable socket -20to +125°CAmbient temperature for electrical connection Attached cable-20to +100°CAt ambient temperature of -30°C restricted function. Only use when stationary. Risk of cable break.Round plug M12×1-20to +100°C Bayonet connector -20to +100°C Cable socket -20to +100°C Storage temperature for electrical connection Attached cable -30to +100°C Round plug M12×1-40to +100°C Bayonet connector -40to +100°C Cable socket -40to +100°CAdmissible humidity Operation 100% rel. humidity including condensation on the device outer case Storage90% rel. humidity without condensationAdmissible mechanical load Vibration resistance 50g for 10to 2000Hz, according to IEC 60068-2-6Shock resistance50g for 3ms, 100g for 2ms, according to IEC 60068-2-27Electromagnetic compatibility according to EN 61326-2-3Interference emission Class B aInterference immunity Industrial requirement Protection typefor electrical connection according to EN 60529Attached cable IP67QUICKON b IP67Round plug M12×1cIP67Bayonet connector c IP67Cable socket c, dIP65a The product is suitable for industrial use as well as for households and small businesses.b Connecting cable diameter, minimum 3.5mm, maximum 6mmc The protection type is only achieved with a suitable mounted counter piece.dConnecting cable diameter, minimum 6mm, maximum 8mmPage 5/10Data Sheet 401002Auxiliary powerApprovals/approval marksVoltage supply U B a4to 20mA, two-wire (output 405)DC 8to 30V, rated voltage supply DC 24V DC 0.5to 4.5V, three-wire (output 412)DC 3to 5.25V, rated voltage supply DC 5V,ratiometric output 10to 90% of the voltage supply DC 0to 10V, three-wire (output 415)DC 11.5to 30V, rated voltage supply DC 24V DC 1to 5V, three-wire (output 418)DC 8to 30V, rated voltage supply DC 24V DC 1to 6V, three-wire (output 420)DC 8to 30V, rated voltage supply DC 24V Current consumption incl. load 4to 20mA, two-wire (output 405)≤25mA DC 0.5to 4.5V, three-wire (output 412)≤3mA DC 0to 10V, three-wire (output 415)≤3mA DC 1to 5V, three-wire (output 418)≤3mA DC 1to 6V, three-wire (output 420)≤3mA Reverse voltage protection Yes Electrical circuit SELVRequirementsThe device must be equipped with an electrical circuit that meets the requirements of EN 61010-1 with regardto "Limited-energy circuits".aResidual ripple: the voltage peaks must not exceed or fall below the specified voltage supply values!Approval mark Testing agency Certificate/certification num-ber Inspection basisValid forc UL usUnderwriters LaboratoriesE201387UL 61010-1 (3. Ed.),CAN/CSA-22.2No.61010-1(3. Ed.)Only in connection with extra code 061;observe order detailsPage 6/10Data Sheet 401002DimensionsElectrical connectionPage 7/10Data Sheet 401002Process connectionØ8mm*Extra code 630 pressure channel Ø8mmPage 8/10Data Sheet 401002Connection diagramThe connection diagram in the data sheet provides preliminary information about the connection options. For the electrical connection, only use the installation instructions or the operating manual. The knowledge and the correct technical compliance with the safety information and warnings contained in these documents are mandatory for mounting, electrical connection, and startup as well as for safety during operation.Cable socketnection.Color coding: connecting cable round plug M12×11 BN Brown2 WH White3 BU Blue4 BKBlackThe color coding is only valid for A-coded standard cables!Page 9/10Data Sheet 401002Order details(1)Basic type401002/000JUMO MIDAS C08 – OEM pressure transmitter – basic401002/999JUMO MIDAS C08 – OEM pressure transmitter – basic, special version (2)Input4550to 1.6bar relative pressure 4560to 2.5bar relative pressure 4570to 4bar relative pressure 4580to 6bar relative pressure 4590to 10bar relative pressure 4600to 16bar relative pressure 4610to 25bar relative pressure 4620to 40bar relative pressure 4630to 60bar relative pressure 479-1to +0.6bar relative pressure 480-1to +1.5bar relative pressure 481-1to +3bar relative pressure 482-1to +5bar relative pressure 483-1to +9bar relative pressure 484-1to +15bar relative pressure 485-1to +24bar relative pressure999Special measuring range for relative pressure (3)Output4054to 20mA, two-wire4120. 5to 4.5V, three-wire, ratiometric 4150to 10V, three-wire 4181to 5V, three-wire 4201to 6V, three-wire (4)Process connection383Push-in fitting for pipe/hose 6×4DN 6502G 1/4 DIN EN 837504G 1/2 DIN EN 8375111/4-18 NPT DIN EN 837521G 1/4 DIN 547Rp 1/8 inside 5627/16-20 UNF(5)Process connection material 20CrNi (stainless steel)(6)Material seal 600EPDM 601FKM a 602CR 604FFKM 609NBR999Special materialPage 10/10Data Sheet 401002Accessories(7)Electrical connection 11Attached cable b 23Quickon36Round plug M12×153Bayonet connector DIN 7258561Cable socket DIN EN 175301-803, Form A (8)Extra codes 000None 061UL approval c591Choke in the pressure channel 624Oil and grease free 630Enlarged pressure channel d 876Test reporta Standardb The standard cable length is 2m. Further lengths are available upon request.c The UL approval stipulates use of the pressure transmitter indoors. In addition, process connection 383 as well as seals 609 and 999 are not possible. Special measuring ranges (input) are not allowed to exceed the 60 bar limit.dAn enlarged pressure channel of diameter Ø8mm is only available with process connection 1/4-18 NPT (process connection 511), G 1/4 (pro-cess connection 521) and the seal FKM (seal material 601).(1)(2)(3)(4)(5)(6)(7)(8)Order code ------/ , ...aOrder example401002/000-460-412-504-20-600-36/591aList extra codes in sequence, separated by commas.Minimum order volume for manufacturing devices: 5 pieces Minimum order volume for warehouse devices:1 pieceItemDescriptionPart no.Cable box, straightThe PVC connecting cable is 2m in length and has a 4-pin, straight M12×1 connector with gold-plated contacts on the device side.00404585Cable box, angledThe PVC connecting cable is 2m in length and has a 4-pin, angled M12×1 connector with gold-plated contacts on the device side.00409334。

精密压力调节器Model9000说明书

Precision Pressure Regulators1P r e c i s i o n P r e s s u r e R e g u l Typical Applications• Environmental Analyzers —Helium or Hydrogen Carrier Gas • Precision Nitrogen Control forChemical Analysis• Laboratory and Process GasChromatography applications • Argon Gas Regulation forBioReagent ManufacturingBack Pressure RegulatorModel 9000Precision Pressure RegulatorProduct SpecificationsThe Parker Precision Fluidics Model 9000 Regulator is a compact,spring-loaded, diaphragm operated back pressure regulator. Designed specifically for precision regulation in low-flow gas applications, it controls upstream pressure rather than downstream pressure and is similar to a relief valve in operation. Model 9000 is performance tested under simulated operating conditions and is cleaned for analyticalinstrument service.Features• Direct-acting and non-relieving• Compact design enables panel mounting• All bar stock construction reduces production variation • Bubble tight shut-off• Panel mount applications• Cleaned for Analytical Service Use • Pressure gauge port included •RoHS and REACH compliantPhysical PropertiesPerformance RatingsPerformance Characteristics** Performance characteristics are based on 60 psig (4.14 barg) helium supply pressure at 50 psig (3.45 barg) outlet pressure.2For more information call +1 603 595 1500 or email ppfinfo @Model 9000Typical Flow CurvesTypical Droop (Flow Sensitivity) Curve 30 psig (2.07 barg) Range SpringTypical Droop (Flow Sensitivity) Curve 60 psig (4.14 barg) Range SpringD e v i a t i o n f r o m S e t P r e s s u r e02101001,0003%2%1%0%Flow SCCM Helium PressureD e v i a t i o n f r o m S e t P r e s s u r e2101001,0003%2%1%0%Flow SCCM Helium PressurePrecision Pressure Regulator3P r e c i s i o For more information call +1 603 595 1500 or email ppfinfo @Principle of OperationA backpressure regulator is designed to regulate inlet pressure. The force of the regulator spring holds the valve closed. When the inlet pressure of the process fluid overcomes the spring setting the valve begins to open. Using a backpressure regulator to precisely control upstream gas pressure is typically more accurate than a relief valve.Model 9000Precision Pressure Regulator4For more information call +1 603 595 1500 or email ppfinfo @Mechanical IntegrationDimensionsBasic DimensionsUnits In (cm)Model 9000Precision Pressure Regulator5P r e c i s i o n P r e s s For more information call +1 603 595 1500 or email ppfinfo @Typical Flow DiagramVOC Emissions Monitoring AnalyzerModel 9000Precision Pressure Regulator6For more information call +1 603 595 1500 or email ppfinfo @Ordering InformationInstallation Guide• May be installed in any orientation.• Support inlet and outlet piping to reduce strain on regulator body.Key Things to Remember:• Choice of Diaphragm Materials – Stainless Steel Diaphragms provide extremely low perme-ability. Coated Fabric Diaphragms, available in Buna or FKM, offer unmatched sensitivity.• Fine Pitch Adjusting Stem – 56 threads/in. (2.2 threads/mm) stem for 15 turns resolution pitch on all regulator adjusting stems gives precise control over incremental pressure adjustments.• Bar Stock Construction and Analytical Service Cleaning – Machined from bar stock in your choice of aluminum or stainless steel. All parts are cleaned to procedures developed specifically for analytical service use, minimizing contaminant generation in low-level analyzer applications.• Extensive Choice of Pressure Range – This ensures maximum resolution at specificpressure and temperature requirements.NOTE: In order to provide the best possible solution for your application, please provide the following requirementswhen contacting Applications Engineering: • Media, Inlet & Outlet Pressures • Mimimum Required Flow Rate.Please click on the ORDER ON-LINE button (or go to www.parker .com/prescision fluidics/regulators) to configure your Precision Pressure Regulator. For more detailed information, visit us on the web orcall Applications Engineering.Model 9000Precision Pressure Regulator7P r e c i s i o n Portfolio ReviewModel 4000Flow control from 0.5 slpm to 10 slpmSmaller SizeModel 9000Model 8286Models 8310 & 8311CustomizationContact Division Applications at (603) 595 1500 or ppfinfo @parker .com.PPF PPR - 002/US October 2016© 2016 Parker Hannifin Corporation Parker Hannifin Corporation Precision Fluidics Division 26 Clinton Dr., Unit 103Hollis, NH 03049Flow control from 1 sccm to 3 slpmFlow control from 1 slpm to 40 slpmFlow control from 10 sccm to 1 slpm Back Pressure RegulatorModel 9000Precision Pressure Regulator。

PC900 410温度控制器中文说明书

ALTECRPC900系列智能程序控制器使用说明书MICROPROCESSOR-BASEDPROGRAMMABLE CONTROLLERPC900INSTRUCTIONMANUAL1.概述......................................................................................................012.功能特点................................................................................................013.型号定义................................................................................................4.仪器安装..............................................................................035.电气连接................................................................................................056.面板介绍................................................................................................107.面板显示及操作....................................................................................8.9.故障显示..................................................................................................................................................................18....................................................................................20串行数字通讯...........................................................................24.............................................................................................26.............................................................................................29 (29)02………………11…………………………………………………………13PID参数整定………………………………………………………………………………17………………17…………软件组态(功能参数的设置)10.11.线性过程输入12.曲线程序控制器13.14.特殊功能技术参数输入信号测量范围目 录1、概述PC900系列智能调节器具有10条*16段温度曲线,特别适合于需多条控温曲线的实验电炉或环境实验设备等场合使用,具有两路输入信号,第2路输入信号可作为模拟遥控设定或电流反馈等特殊用途使用。

GPT-9800_四合一安规测试仪(交直流耐压+绝缘+接地)说明书


接地阻抗 [GPT-9804]
輸出電流範圍 輸出電流調整解析度 輸出電流準確度
測試電壓 測試電壓頻率 電阻量測範圍 電阻量測解析度 電阻量測準確度 上/下限判.00A~30.00A ac 0.01A
3A≦ I ≦8A: ±(1%讀值+ 0.2A) 8A< I ≦30A: ±(1%讀值+ 0.05A)
GPT-9803
200VA 交流耐壓/直流耐壓/絕緣電阻 安規測試器
GPT-9802
200VA 交流耐壓/直流耐壓 安規測試器
GPT-9801
200VA 交流耐壓 安規測試器
(*) 全系列 2 年保固, 不包含附件
標準附件
快速指南 x 1, 電源線 x 1, CD x 1(內含完整使用手冊) Interlock 端子 x 1 Remote 端子組件 x 1 測試線 GHT-114 x 1 for GPT-9803/9802/9801 測試線 GHT-114 x 1, GTL-115 x 1 for GPT-9804
GPT-9800 系列安規測試器共計有 4 個型號:GPT-9804 是 4 合一機種,具有交/直流耐壓測試、絕緣 電阻測試及交流接地阻抗測試功能、GPT-9803 提供交/直流耐壓測試及絕緣電阻測試功能、GPT-9802 具有交流及直流耐壓測試功能,而 GPT-9801 則僅提供交流耐壓測試功能。全系列機型提供交流 200VA 輸出容量,並使用高效率的 PWM 放大器,有效避免因輸入電源電壓變動或波形變形的影響,以確保 交流耐壓測試時對待測物提供穩定之高壓輸出。
± (1%讀值+ 5V) 0.001mA~ 10.0mA 0.001mA / 0.01mA / 0.1mA ±(1.5%讀值+ 30uA)

温度传感器简介


(二)热电偶产品简介 1、热电偶材料按分度号分为 B、R、S、N、K、E、J、T、WRe3- Wre25、Wre5- Wre26 等 10 个标准形式,此外还有一些非标丝材
可供选择。不同分度号的热电偶测温范围、优缺点也不相同,根据需要选择合适分度号的测温产品。
标准化热电偶的主要性能列表如下:
热偶品种
引脚说明:GND:地 VDD:可供选用的外部电源,不用时接地
21.036 28.946
37.005

700
800
900
1000
mV
53.112 61.017
68.787 76.373
参考端非 0℃时校正表

0
10
20
30
40
(校正值+相应温度 mV 值) mV
0
0.591
1.192
1.801
2.420
600 45.093
50 3.048
(三)DS18B20 数字温度传感器简介
2012/13 工控产品手册 pure-china@ 3
九纯健科技-传感与测控专家
温度产品手册
单位 镍铬-镍铜(康铜)热电偶(E 型) 热电动势 mV 与温度值对照表(参考端 0℃时)

-200
-100
0
100
200
300
400
500
mV
-8.825
-5.237
0
6.319
13.421
1180
190
168.48 172.17
280
290
204.90 208.48
700
750
345.28 360.64
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

•• • • • 数字补偿,高精度高稳定性
坚固的不锈钢结构测试标准的理想选择高破坏压力
产品说明
P9000系列是采用最新先进技术研制而成的数字补偿式压力传感器。

其独有的设计采用了可靠性已经验证的应变片技术和全新的数字补偿原理和方法,这些技术融合成为高性能的、先进的仪表级压力传感器。

压力范围从75Psi到10,000Psi(5bar到700bar)。

为满足大多数的压力检测要求,P9000系列产品提供多种压力端口、电气输出和输出端口选项。

P9000系列产品采用12位数字补偿微处理器,保证了所有高规格参数的精密校准。

这种电路设计同时提供了一个独特的优越性,即提供了一个类似的模拟“通路”以产生1000Hz的快速响应频率,从而不影响测量精度。

误差被数字校正到承诺的性能参数并且无需用户校正。

非线性、迟滞和重复性误差低于±0.08% F.R.O.。

在-4℉到85℉(-20℃到85℃)温度范围内,总不确定度低于±0.004% F.R.O./℃。

P9000系列产品利用17-4PH不锈钢作为压力膜片,真正实现抗腐蚀屏障并且破坏压力大于20倍压力量程,极限压力大于5倍压力量程。

可侵入性符合IP67国际标准,抗冲击性达1000g/5ms,抗振动性达到±20g,P9000系列产品是能适应于各种恶劣应用环境下传感器的最佳选择。

P9000系列产品具备电缆线输出和接插件输出两种类型,提供多种电气输出:4线制0~10V、4线制0到5V和2线制4~20mA(可选本安防爆型)。

P9000系列产品还可以提供3线制1~6V或1~11V输出。

所有P9000系列产品均符合ISO9001认证,每个传感器出厂时都编有序列号和附带校准数据证书。

• • • • • • • • • • • • • •
特点
应用
精度高于±0.08%F.R.O 坚固的不锈钢结构
压力范围:0~75Psi到10000Psi(0~5Bar到700Bar)5倍过载压力
可侵入式符合IP67国际标准长期稳定性0.1%F.R.O./每年
温度漂移:<0.002%F.R.O./℉(0.004%F.R.O./℃)CE认证
液压和气压控制钢、铝扎厂食品厂、造纸厂汽车实验台发电站
近海石油开发
1
1
-
-
% F.R.O./ °F % F.R.O./ °C
5.11 (145) 5.11 (145) 5.11 (145)
6.35 (180)
6.35 (180)
6.35 (180)
% F.R.O.
产品型号输入电压
输入电流(mA)
满量程输出阻抗(Ω)响应频率零点误差
重量(OZ/克)接插件输出型
电缆线输出型
系列 负载阻抗(Ω)
P9060 P9070 P9080
P906X
P907X P908X
10~36VDC
15~36VDC 10~36VDC
6 <6 N /A
5V±0.3%
10V±0.3% 4~20mA(16mA±0.3%)1000
2000
1300最大(36V)
1 kHz
1kHz
1kHz 非线性、迟滞和重复性误差
高压 %F.R.O.(BSL)
0.05典型
0.05典型0.05典型
0.08最大
-
零位和满量程漂移误差:(在-20~80℃温度范围内,以20℃为
起点,输出误差不会超过0.5%F.R.O/℃)<±0.002 <±0.002 <±0.002 <±0.004 <±0.004 <±0.004 ±0.3%
±0.3%
±0.3%
性能参数
6, 10, 16, 25, 40, 60, 100, 160, 250, 400, 600
1
-40°F to 212°F (-40°C to 100°C) 4°F to 176°F (-20°C to 80°C)
-40°F to 257°F (-40°C to 125°C)
1
P9000系列高性能金属应变式压力传感器
通用标准
所有参数均指在温度20℃下所呈特性(除非特别注明)
压力范围高压(Psi) (Bar)中压(Bar)参考压力高压中压压力极限
破坏压力
压力介质电路自校准非线性、迟滞和重复性综合误差温度
工作温度补偿温度储存温度湿度
接插件输出型电缆输出型加速度响应抗振动冲击EMC
绝缘电阻
0-75, 100, 150, 200, 250, 350, 500, 750, 1000, 1500, 2200, 3500, 5000, 7500, 10,000
0-5, 7, 10, 15, 25, 35, 50, 70, 100, 150, 200, 250, 350, 500, 700 通气表压 (以当地大气压为参考压力)产品限于测量压力:0~75至0~350Psi
绝压和密封表压(以密封大气压为参考压力)限于测量压力:0~75至0~10000Psi
通气表压 (以当地大气压为参考压力)或绝压:0~10,15,20,25,35Psi。

1
≥20倍满量程压力或22000Psi/1520Bar(两者取较小值)。

≥5倍满量程压力或12000Psi/830Bar(两者取较小值),不会引起零点漂移超过0.4%F.R.O.
(可在几小时内复位)
与17-4PH&17-7PH不锈钢兼容或Inconel625兼容的气体或液体。

80% ±5%满量程输出(不适合P9080系列)
高压:±0.10%F.R.O(BSL);中压:±0.20%F.R.O(BSL)
95%相对湿度
可浸入性符合IP67国际标准(液体务必不能进入电缆线的末端)<± 0.02% F.R.O./g <±0.10% F.R.O./g (当压力低于于500Psi/35Bar)(当压力高于500Psi/35Bar)优于MIL STD 810C Method 514-2 Curve L和EUROCAE ED 14A/RTCA 160A特性。

1000g/5ms不会损坏
P9000系列有CE标记产品,表示在正确安装的情况下,产品符合关于住宅、商业、轻工业和工业环境中的EMC的通用标准EMC Directive 89/336/EEC。

注:P9080系列本安防暴产品不符合工业环境指令。

500MΩ(50VDC,25℃)
通气表压(以当地大气压为参考压力)产品必须可通过输出接插件的孔或电缆线的通气管与非腐蚀性的干燥环境通气。

G1/4A (BSP) (F) 0002 0.46 (11.7) 0.67 (16.9) M14 x 1.5 (M) 0003 0.40 (10.2) 0.61 (15.4) 7/16” -20UNF-2A (M)
0004 0.56 (14.3) 0.77 (19.5) 1/4” -18NPT (M) 0005 0.55 (14.0) 0.76 (19.2) M10 x 1.0 (F)
0006
-
0.60 (15.2)
1/4" -18NPT (F)
0009
G1/4A (BSP) (F) 0022 0.46 (11.7) 0.70 (17.8) M14 x 1.5 (M) 0023 0.40 (10.2) 0.62 (15.8) 7/16” -20UNF-2A (M)
0024 0.56 (14.3) 0.78 (19.8) 1/4” -18NPT (M) 0025 0.55 (14.0) 0.80 (20.4) M10 x 1.0 (F)
0026
-
0.60 (15.2)
(P90X3-XXXX)A /F
0.67P9000系列高性能金属应变式压力传感器
产品尺寸
所有尺寸标注单位为:英寸(毫米)
连接器输出
螺纹G1/4B [BSP]压力接口,焊接紧固型
压力接口,螺纹拧紧型
压力接口
编号 尺寸 英寸/毫米
A
B
螺纹尺寸
焊接紧固型
编号 尺寸 英寸/毫米
A
B
螺纹尺寸
焊接紧固型
A & SG.
VG.2
1 1
1 1
电气连接
电缆
接插件红色白色黄色蓝色紫色灰色引脚A 电源+引脚D 电源-引脚B 输出+
引脚C 输出-
引脚E 引脚F
80%F.R.O电路自校准接插件方向
备注:有CE标记的产品屏蔽线连到外壳,IS认证产品(P980)的屏蔽线不连到产品外壳。

IS认证和CE认证不能同时满足。

1. 两线输出传感器。

2. 通气表压以大气压为参考压力产品必须通过接插件通气(配用接插件必须留有通风孔)。

电气连接
P906X 和 P907X
P908X
红色 A 黄色 B
蓝色 C
白色 D 紫色 E 灰色 F
引脚F-仅限于工厂使用
产品选型示例
选型示例: P9061-0002-7K5PSS = 0~5V 输出 10~36V 供电, 电缆输出,1/4”BSP 外螺纹, 7500 psi 密封表压。

相关文档