一种双余度无刷直流电机转矩脉动抑制控制策略研究
双余度永磁无刷直流电机设计与实验研究

双余度永磁无刷直流电机设计与实验研究付朝阳;刘景林;金英汉【摘要】In order to improve the reliability of the system, the redundancy technology is introduced into the design of permanent magnet BLDCM. Sections 1 through 3 of the full paper explain our design, computer simulation and experimental research; we believe that our design is effective. The core of section 1 consists of; (1) two kinds of stator structure are designed, including one slot and two slots; ( 2 ) the mathematical model of the motor is set up; the winding inductance is analyzed and calculated, and the relationship between the winding inductance and mutual inductance is deduced. The core of section 2 is that, according to the mathematical model, the parameters of the motor are designed and the rotational speed and torque are simulated. The core of section 3 consists of; (1) the motor is tested on the MAGTROL testing system; ( 2 ) the mechanical characteristic curves of both kinds of stator structure under different working modes are compared. The simulation results are given in Figs. 3 through 6 and the experimental results are given in Figs. 7 through 12. Both the simulation and the experiment results show that; (1) the motor of each kind can achieve good dynamic characteristics and the torque is increased by 100% with two sets of windings; ( 2) two sets of winding did not affect motor performance, but it did indeed greatly improve the system reliability.%为了提高系统可靠性,将余度技术引入到永磁无刷直流电机设计中.设计了2种定子绕组方式,包括同槽嵌放和隔槽嵌放结构.建立了2种结构下的数学模型,对绕组电感进行了分析计算,推导了绕组自感和互感之间的关系.根据数学模型,设计了双余度永磁无刷直流电机的具体结构参数,对转速和转矩进行了仿真.利用magtrol测试系统对双余度永磁无刷直流电机进行了实验,对比分析了2种结构不同工作模式下的机械特性曲线.实验结果表明:2种结构的双余度无刷直流电机在运行过程中,具有良好的动态特性,2套绕组同时工作时其转矩为1套绕组工作时的2倍;2套绕组并未对电机性能产生不良影响,但大大提高了系统可靠性.【期刊名称】《西北工业大学学报》【年(卷),期】2012(030)005【总页数】5页(P724-728)【关键词】双余度;永磁无刷直流电机;设计;实验【作者】付朝阳;刘景林;金英汉【作者单位】西北工业大学自动化学院,陕西西安710072;西北工业大学自动化学院,陕西西安710072;西北工业大学自动化学院,陕西西安710072【正文语种】中文【中图分类】TM301.2近年来,随着稀土永磁材料的快速发展,永磁电机不仅使电机的重量、体积明显减小,而且改善了电机的动态特性,减小了由于齿槽效应引起的力矩波动,简化了磁路设计和磁场分析方法。
一种抑制无刷直流电动机换相转矩脉动的新方法

一种抑制无刷直流电动机换相转矩脉动的新方法魏嘉涛;林荣文【摘要】无刷直流电动机具有传统直流电动机的优点,可以低速大功率运行,可以省去减速机直接驱动大的负载,同时体积小、重量轻、出力大.因此,在各行各业得到了广泛的应用.但缺点是转矩脉动较大.在Z源逆变器的基础上,本文提出用一种改进型的Z源逆变器来抑制无刷直流电动机换相转矩脉动,改进型的Z源拓扑相对于传统拓扑减少了一个电容.因此可减小电路的体积及设计成本.该拓扑的升压能力与传统拓扑相当,并且不存在传统拓扑那样的起动回路,不存在起动冲击问题,无需采用软起动策略,起动过程简单.而且能够有效地抑制换相转矩脉动.【期刊名称】《电气技术》【年(卷),期】2017(000)003【总页数】5页(P16-20)【关键词】无刷直流电动机;转矩脉动;改进型Z源逆变器【作者】魏嘉涛;林荣文【作者单位】福州大学电气工程与自动化学院,福州 350108;福州大学电气工程与自动化学院,福州 350108【正文语种】中文无刷直流电动机具有输出转矩大、高效率、低效率、控制简单等特点,被广泛的应用在各行各业。
转矩特性是电动机性能的重要指标,无刷直流电动机的换相、齿槽效应、电枢反应等,都会产生转矩脉动。
齿槽效应、电枢反应产生的转矩脉动可以通过电动机设计来减少。
因此,无刷直流电动机的转矩脉动主要来源于换相时产生的转矩脉动。
有效地控制减少无刷直流电动机换相时刻产生的脉动,就能使电机稳定运行。
文献[2]分析了采用合理的PWM调制方式以及合适的重叠换相角减小电动机转矩脉动的理论。
但是要精确计算导通角,否则可能增大转矩脉动。
文献[3]分析了无刷直流电动机两种导通方式(二二导通和三三导通)下的转矩脉动。
通过比较发现在低速时候采用二二导通,转矩脉动小;在高速的时候采用三三导通,转矩脉动小。
文献[6]在对永磁直流电动机建立数学模型的基础上,对5种传统的PWM调制方式进行详细分析和比较。
通过比较发现在抑制换相期间电磁转矩脉动方面PWM_ON调制方式比其他四种调制方式具有更好的控制效果。
无刷直流电机基于电流预测控制的转矩脉动抑制

无刷直流电机基于电流预测控制的转矩脉动抑制作者:吕德刚张辰光侯征东来源:《哈尔滨理工大学学报》2020年第05期摘要:针对无刷直流电机转矩脉动问题,提出了一种与换相重叠法相结合的电流预测控制方法来抑制换相转矩脉动。
在分析换相转矩脉动产生的原因的基础上,采用电流预测控制方法同ON_PWM导通方式相结合,对电机进行控制。
在换相期间对关断相和非换相相采用同步的PWM进行调制,确保在换相期间开通相的电流上升率和关断相电流的下降率相同,从而使非换相相电流在换相期间平稳过度,进而减小转矩脉动。
在电流预测控制的基础上,通过消除直流母线负续流,进一步抑制转矩脉动。
实验表明,本文提出的方法可在中低速范围内明显的减小转矩脉动,验证了该控制策略的正確性;消除直流母线负续流,转矩脉动得到进一步抑制。
关键词:无刷直流电机;转矩脉动;重叠换相;直流母线负续流;电流预测Abstract:Aiming at the torque ripple problem of brushless DC motor, a current predictive control method combined with commutation overlap method is proposed to suppress the commutation torque ripple. Based on the analysis of the cause of the commutation torque ripple, the current prediction control method is combined with the ON_PWM conduction mode to control the motor. During the commutation phase, the off-phase and non-commutation phase are modulated by synchronous PWM, ensuring that the current rise rate of the turn-on phase during commutation was the same as the turn-off phase current drop rate. Thus the non-commutated phase current was smoothly over-transformed during commutation, which in turn reduces torque ripple. On the basis of the current prediction control, the torque ripple was further suppressed by eliminating the negative current of the DC bus. Experiments show that the proposed method can significantly reduce the torque ripple in full speed range, verify the correctness of the control strategy, eliminate the DC bus negative freewheeling, and further suppress the torque ripple.Keywords:BLDCM; torque ripple; overlap commutation; DC bus negative freewheeling; current prediction0 引言由于存在转矩脉动,使得无刷直流电机很难应用于高精度高稳定性场合[1],为了解决该问题,国内外学者做了大量的研究[2-5]。
一种减少无刷直流电机转矩脉动的新方法

一种减少无刷直流电机转矩脉动的新方法
王文韬;冯江华;许峻峰
【期刊名称】《电子设计工程》
【年(卷),期】2010(18)4
【摘要】为了抑制永磁无刷直流电动机控制系统在换相过程中因电流波动引起的转矩脉动,提高系统效率及稳定性,提出一种基于控制换相电流的新方法.与传统方法相比,该方法以换相电流为研究对象,通过使关断相电流的下降率等于开通相电流的上升率采维持电流在换相期间的稳定,从而减少转矩脉动,它摒弃了传统方法中的以转矩为研究对象.实验结果表明,该方法在地铁屏蔽门的应用中取得良好效果,使电流波动减少8%,转矩脉动减少10%.
【总页数】4页(P108-111)
【作者】王文韬;冯江华;许峻峰
【作者单位】湖南工业大学,电气与信息工程学院,湖南,株洲,412008;南车株洲电力机车研究所有限公司,湖南,株洲,412001;南车株洲电力机车研究所有限公司,湖南,株洲,412001
【正文语种】中文
【中图分类】TM3;TP3
【相关文献】
1.一种抑制无刷直流电机转矩脉动的新方法 [J], 谢少华;瞿遂春
2.无刷直流电机转矩脉动控制新方法 [J], 邓福军;刘思华
3.无刷直流电机转矩脉动抑制新方法 [J], 朱燕青;史旺旺
4.开通角控制的无刷直流电机转矩脉动抑制新方法 [J], 李轶华;王爱元;王明星
5.减小无刷直流电机的转矩脉动的新方法 [J], 诸德宏;李明达;刘成;刘鉴;简耀因版权原因,仅展示原文概要,查看原文内容请购买。
一种简单的无刷直流电动机转矩脉动抑制方法

一种简单的无刷直流电动机转矩脉动抑制方法荣军;李一鸣;万军华;张敏;陈曦【期刊名称】《微特电机》【年(卷),期】2015(043)011【摘要】针对无刷直流电动机电流换相转矩脉动产生的机理,研究了一种简单的转矩脉动抑制方法.它区别于传统电机参数选择困难以及转矩脉动过大等缺点,研究了直接面向换相转矩脉动的抑制方法.具体做法就是直接令推导出的换相转矩脉动等于零,然后根据其数学公式反推出其换相时对应的占空比和换相时间,通过理论分析,只要在合理的换相时间内能够将占空比取到理论计算值,就可以消除换相转矩脉动.最后在PSPICE中建立了在HPWM-LON调制模式下转矩脉动抑制数学模型并进行了仿真,通过对仿真结果的比较分析,直接面向换相转矩脉动的抑制方法在消除转矩脉动方面具有较好的效果.【总页数】6页(P72-76,89)【作者】荣军;李一鸣;万军华;张敏;陈曦【作者单位】湖南理工学院,岳阳414006;长沙理工大学,长沙410014;湖南理工学院,岳阳414006;长沙理工大学,长沙410014;湖南理工学院,岳阳414006;长沙理工大学,长沙410014;湖南理工学院,岳阳414006;长沙理工大学,长沙410014;湖南理工学院,岳阳414006;长沙理工大学,长沙410014【正文语种】中文【中图分类】TM33【相关文献】1.一种抑制无刷直流电动机换相转矩脉动的新方法 [J], 魏嘉涛;林荣文2.一种抑制无刷直流电动机转矩脉动的新方法 [J], 吴昊;孙新亚;吉吟东3.基于模型预测控制的无刷直流电动机转矩脉动抑制方法 [J], 张有全;崔巍;廖憬4.抑制无刷直流电动机齿槽转矩脉动的设计方法 [J], 陆静平5.永磁无刷直流电动机换相脉动转矩及抑制方法 [J], 肖遥剑;冯浩;仰韩英;赵浩因版权原因,仅展示原文概要,查看原文内容请购买。
无刷直流电动机换相转矩脉动抑制新策略

0引 言
无刷 直流 电动机 由于优 良的性 能在家 电和工 业 中有 着广 泛运 用 。传 统 的控 制 方 式下 , 相绕 组 电感
杂程 度 。文 献 [ 1 0 — 1 1 ] 对 换 相 过 程 进行 了补 偿 , 有 效抑 制转矩 脉动 , 但 换 相过 程 中需 要 检测 的量 比较
( S h a n g h a i U n i v e r s i t y , S h a n g h a i 2 0 0 0 7 2 , C h i n a )
Ab s t r a c t : A n o v e l p u l s e - w i d t h m o d u l a t i o n( P WM)t e c h n i q u e f o r b r u s h l e s s D C m o t o r( B L D C M)d r i v e s w a s p r e s e n t e d
a n t t h e v a l i d i t y o f p r o p o s e d s c h e me . Ke y wo r d s : b r u s h l e s s DC mo t o r ; c o mmu t a t i o n t o r q u e r i p p l e ; DC b u s c u r r e n t c o n t r o l ; p u l s e — w i d t h mo d u l a t i o n
双余度无刷直流电机控制系统1

微电机专题2006年第7期 11双余度无刷直流电机控制系统刘卫国 马瑞卿(西北工业大学稀土永磁电机及控制技术研究所 西安 710072)摘要 介绍了余度技术及其在电机设计中的应用,针对航空双余度无刷直流电机控制系统,分析了双余度电机的基本结构形式、控制系统结构与工作原理、控制方法等。
关键词:双余度 无刷直流电机Research on Dual-redundancy Brushless DC Motor Control SystemLiu Weiguo Ma Ruiqing(Northwestem Polyechnical University XI’an 710072 China )Abstract The redundancy technique and its application on motor design are introduced. The fundamental structure of dual-redundancy motor is presented. The constitution, operation principle and control strategy of control system are analyzed.Keywords: Dual-redundancy ,Brushless DC Motor1 前言 余度,在可靠性工程中定义为:使用一套以上的设备来完成给定的任务,即构成余度。
余度技术是指通过为系统增加多重资源,包括硬件与软件的重复配置,实现对多重资源的合理管理,从而提高产品和系统可靠性的设计方法。
它是当其他技术(采用更好的部件、简化和降额)不能解决提高可靠性的问题或当产品改进方法所需费用比之重复配置所需费用更多时可采用的方法。
由于余度技术是提高系统安全性与可靠性的一种手段,因而在需要高可靠性或超高可靠性的系统,如航空航天飞行控制、空中交通管制、通信系统的计算机管理及核电站控制等工程应用领域得到广泛应用。
无刷直流电机换向转矩脉动分析与抑制

j = a, b, c
p
j j
= 2pke i0 + p
ke (2Udc D - 8keω - 6R i0 ) t 3L ( 9)
忽略 稳 态 时 的 电 流 波 动 , 稳 态 时 电 机 电 磁 转 矩 为
[ 6, 7 ]
与上桥换相的推导过程类似 , 下桥换相过程中 的电磁转矩脉动为 ΔTD = T0 - TD = p
∑
S =1 ( 3) S =0
1 ei 3 i = a, b, c
∑
在 V2V3 区间内 , eb = - ec = keω, ke 为电磁转矩常
第 3期
无刷直流电机换向转矩脉动分析与抑制 相转矩脉动的偏差为 ΔT1 =ΔTU - ΔT ′ U =p
289
数 , 而 ea 是一个斜坡函数 。另外 , 中性点电压还受 到 PWM 调制的影响 , 因此 , 其动态表达式实际上是 一个非常复杂的函数 。由于换相过程比较短 , 令 ea ≈ keω; 同时令式 ( 3 ) 中的
ic ( t) = - i0 +
在下桥换相过程中 , pwm - on 和 H - on - L - pwm 调制方式的续流过程相同 。假设 V4 关断 , V5 恒 通 , V6 为 PWM 调制 , 则 A 相续流过程中电流回路 如图 3 所示 。
1 ( 4 keω + 3R i0 - DU dc ) t 3L
第 10 卷 第 3期
2006 年 5 月
电 机 与 控 制 学 报 EL EC TR IC MA CH IN E S AND CON TROLVolBiblioteka 10 No13 M ay 2006
无刷直流电机换向转矩脉动分析与抑制
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
2017钲 第38卷 1月
第1期 郑州大学学报(工学版) Journal of Zhengzhou University(Engineering Science) Jan. 2Ol7
V01.38 No.1
文章编号:1671—6833(2017)01—0050一O6
一种双余度无刷直流电机转矩脉动抑制控制策略研究
刘卫国,霍 达,谭 博,公 超 (西北工业大学自动化学院,陕西西安710129) 摘要:针对两套并联绕组互差30。电角度的双余度无刷直流电机换相转矩脉动问题展开研究.提出一 种基于变结构电流前馈的转矩控制方法.该方法结合对应相绕组轴线互差3O。的特点,在均流控制的前 提下,使用变结构控制策略独立控制两套绕组的电流以保证电机在换相时刻输出稳定的转矩.为了增加 电流的响应速度,采用电流前馈控制方法提高电流的变化率.在MATLAB/Simulink环境下搭建模型进 行仿真.结果表明,与传统的双余度电机均流控制策略相比,基于变结构电流前馈的转矩控制策略能够 有效地降低电机的换相转矩脉动. 关键词:双余度;变结构电流前馈控制;转矩脉动;无刷直流电机 中圈分类号:TM33 文献标志码:A doi:10.13705/j.issn.1671—6833.2016.04.031
0 引言 目前,在现代航空航天设备中电力传动系统 已经逐步开始取代传统的气动和液压传动系 统¨。 ,而电机作为现代航空航天设备的电力传 动系统中重要的执行元件,保证电机在整个系统 的高可靠运行格外重要 .永磁材料的性能优化 也为电机应用于航空航天领域奠定了基础 .为 了增加系统的可靠性,双余度无刷直流电机正在 被广泛地应用于航空航天等对可靠性要求高的领 域 .根据双余度无刷直流电机在结构上的不 同,可分为两种类型:并联结构型和串联结构 型 .串联结构电机体积较大且两套绕组同槽 放于定子铁心上;并联结构电机两套独立的电枢 绕组互差30。隔槽嵌放于定子铁心上.笔者研究 的是基于两套绕组隔槽嵌放的电机结构.双余度 无刷直流电动机的转矩脉动是影响其调速性能的 因素,转矩脉动的有效抑制是近年来无刷直流电 机领域研究的热点和难点 .转矩脉动产生的 原因主要有:换相引起的转矩脉动、电磁因素引起 的转矩脉动、电枢反应引起的转矩脉动和齿槽效 应引起的转矩脉动…,笔者从控制角度分析,对 于双余度无刷直流电机换相转矩脉动抑制问题展 开探究.文献[9]从理论上详细分析了换相转矩 脉动产生的原因并推导出转矩脉动公式,提出了 一种基于电流预测控制的换相转矩脉动抑制方 法,并通过实验验证了该算法的有效性;文献 [10]通过研究非换相的相电流在换相时期的变 化,提出了保持非换相电压不变的方法抑制转矩 脉动,实验验证了该算法的可行性.笔者针对两套 并联绕组互差30。电角度的双余度无刷直流电机 转矩脉动问题展开研究.
1 双余度无刷直流电动机换相转矩脉动 分析
在不考虑任何PWM调制的前提下,对两个 余度的换相转矩脉动进行分析. 双余度无刷直流电机功率拓扑结构如图1所 示,图中T1一T6和D1~D6是余度1的功率开关 器件;T7~T12和D7一D12是余度2的功率开关 器件;a、b、c和a 、b 、c 分别是余度1和余度2三 相星形联接的集中式整距绕组,a和a 、b和b 、c 和c 的绕组轴线互差30。电角度隔槽嵌放. 假设余度1处在换相阶段,由a、b相换到a、c 相,开关状态为Tl、T6开通切换至T1、rI'2开通. 因b相电流无法突变,要经过二极管进行续流,其 续流回路如图2所示.换相完成后Tl、T2开通回 路如图3所示.
收稿日期:2016—03—25;修订日期:2016—05—18 基金项目:高等学校博士学科点专项科研基金资助项目(20136102120055) 作者简介:刘卫国(1960一),男,河南正阳人,西北工业大学教授,博士生导师,主要从事运动控制、电气伺服控制 以及电机控制技术的应用与研究等,E-mail:1wglll@nwpu.edu.cn. 第1期 刘卫国,等:一种双余度无刷直流电机转矩脉动抑制控制策略研究 51 T。 如。 5 70v= 一柳4柞
图1 双余度功率拓扑结构示意图 Fig.1 Dual-redundancy power topology
图2 b相续流回路电路 Fig.2 Continuous current loop in phase b
图3 T1和T2导通等效电路 Fig.3 Equivalent circuit when T1 and T2 are on
图2和图3中工为电感自感, 为电感间的 互感,由两个等效电路可列出方程组为: 『(L- ) di,UVlA R+警=0lea + 1A尺+ +fnR+( — )云 0;
e 圳孥圳苦uva I ea + 2^尺+( 一 ) ¨ R+( 一 ; 隧
. (1)
TeA( ): ( + + : : 【 3 L M…,]’(2) 【(一)… J’
dt: [ 3 M】'㈩ ∞【( 一 )J’
式中:, 为换相过程中a相电流的初始值. 余度2正常导通,对应a ,b 相导通,C 相关 断.等效电路如图4所示.
图4 T7和T12导通等效电路 Fig.4 Equivalent circuit when T7 and TI2 are on
由等效电路可列出方程组为: 。 +( 一 . dil. (L-R = ; ln+( 一 + a, +( )
I。= ;
1 ib,=一i。 ; (4) I i ,=0; 【e ,=一eb,=一e ,=E. 根据无刷直流电机转矩方程可推得余度2转 矩为:
T。B(t)= 一(eati ,+eb,ib,+ec,i .)=
= 【 H 12]2 M,㈣ ∞【( 一 )‘。 ’ 余度2的换相转矩脉动为: = [ 2 M]㈤ d£ ∞【 ( 一 )J’ 、。 式中:12为at相电流的初始值. 两个余度的合成换相转矩脉动为:
= =昙【 】.㈩
当反电势E<5U/14时,换相转矩脉动为正; 当反电势E=5U/14时,换相转矩脉动为零;当反 电势E>5U/14时,换相转矩脉动为负.
2 变结构电流前置反馈补偿的转矩控制 2.1 双余度无刷直流电机传统控制策略 目前,双余度无刷直流电动机的主要控制方 案之一为采用两个余度均流控制¨ ” ,其控制框 架如图5所示. 系统组成包含控制器、驱动器和电动机3部 分.其中控制器完成速度闭环,并且实现余度管 理,驱动器分别包含两个独立的驱动单元A和B, 电机包含两套独立的绕组和一个旋转变压器,旋 转变压器作为转子位置和速度传感器. 52 郑州大学学报(工学版) 2017矩 驱动器A I 余度1参考 余度l电流反馈
嚣一网壤 商』 冒 给定一『同嘉差_ 一、f一幽 箍H
I 蓖 … 余度2电流匣馈 控制器l i 速度反馈 驱动器B 一
图5均流控制系统原理框图 Fig.5 Current-sharing strategy system
均流控制原理为:两个余度共用一个速度环, 由旋转变压器得到的转速反馈与给定转速进行计 算,输出的差值经过PI调节器后再经1/2均流处 理作为两个余度电流环的输入.电流环的给定与 采样余度的电流反馈信号计算产生PWM信号输 出到驱动电路模块,驱动信号控制开关管的导通 时序在绕组中产生脉动旋转磁场,使电机运转. 2.2变结构控制方法 均流控制方法实现了两个余度的均流,但是 没有考虑电机的转矩脉动抑制问题. 根据上述分析,结合双余度绕组并联互差 30。电角度的特征,笔者提出一种变结构的电流前 置反馈补偿的转矩控制方法.切换函数S设计为: 』s 一 = r :一 (8) 【S:=e = 一T =K ( 一i ), 式中:K 为转矩系数常量;em为余度1的转矩估 计误差;e伸为余度2的转矩估计误差. 控制器最终输出设为“。和u ,其表达式为: ul=¥…1+k2S2 sign (t.S kl gn , { : +slsi(£ ), ’ 式中:k。、k2为两个加权系数函数.以a相和at相 为例构造函数sign(t )、sign(t ,),表达式分别为: sis , r0,else; sign(t.,) i1,z +詈 :+詈, 式中:t,为余度1换相开始时刻;t 为余度1换相 结束时刻.余度1换相时刻延迟竹/6即为余度2 的换相时刻. 换相开始时刻t 由转子位置信号获取,将换 相时长△£和换相结束时刻t:代人式(4)得到的方 程组为: ib(f): … ; ㈩ 丽 +』b 2; (12) ib(t2)=0 , =一0 由上式可得: . (13) 其他两相b、C与a相似,分别相差120。和 240。电角度. 构造函数的目的是对两个余度的换相阶段与 非换相阶段进行判断,换相脉动阶段函数值置 “1”,其余阶段置“0”,以区分控制策略中的双绕 组对应的3种工作状态: 1)余度1换相,余度2不换相; 2)余度2换相,余度1不换相; 3)余度1、余度2均不换相. 提出的变结构控制原理框图如图6所示.
余度I电流反馈
余度2电流反馈 图6变结构控制原理框图
Fig.6 Variable structure control method
2.2.1 前馈控制 当余度1出现换相转矩脉动时,变结构控制 通过余度2产生转矩补偿.由于换相过程较短,如 算法的实时性较低,将导致补偿效果较差,甚至产 生震荡.通过电流前置反馈的方法提升控制实时 性,实现快速补偿. 以余度1为例,前馈环节的原理框图如图7 所示.
图7余度1前馈环节原理图 Fig.7 Feedforward control in 1。‘redundancy
图7中前馈环节的传递函数为: G (s): 1 , (14)
式中:M。(s)为电机的传递函数.前馈函数能够使