人防地下室计算书

合集下载

人防地下室侧壁计算 RWQ1.RWQ2

人防地下室侧壁计算 RWQ1.RWQ2

地下室侧壁计算书RWQ1.RWQ2条件:1、土质参数:容重γ=18kN/mmγ` = 11kN/mm Ko=0.50,地下水头高度H1=1000mm;(在负一层)2、地下室参数:覆土层厚Lo=300mm,地下一层层高L1=4500mm,地下二层层高L2=500mm,地下三层层高L3=500mm;地面堆载p=10kN/mm d1=350mm;地下二层d2=500mm;地下三层d3=500mm;临水面保护层为50mm;3、材料参数:混凝土强度等级为C35,fc=16.7 N/mm fy=300N/mm计算:1、荷载计算,土压力按静止土压力计算[《全国民用建筑工程设计技术措施》2.6.2]堆载折算为土压力q1=Ko×p=0.50×10=5.00kN/mm地下水位以上土压力q2=Ko×γ×H1=0.50×18×1000×10=9.00kN/mm地下水位以下土压力q3=Ko×γ`×H2=0.50×11×4800×10=26.40kN/mm水压力q4=γw×H2=10×4800×10=48.00kN/mmqD=q1+Ko×γ×Lo=7.70kN/mmqC=q1+q2+(Ko×γ` +10)×(L1+Lo-H1)=72.90kN/mmqB=q1+q2+(Ko×γ` +10)×(L2+L1+Lo-H1)=80.65kN/mmqA=q1+q2+q3+q4=88.40kN/mm2、弯距计算,按多跨梁弯距分配法支座弯距调幅0.8计算,顶点按铰支座,其余按固支座,按静力计算手册计算Mdc=0;Mcd=1.2×(7×qD+8×qC)×L1/120=129.01 kN.mMcb=1.2×qC×L2/12+1.2×(qB-qC)×L2/30=1.90 kN.mMbc=1.2×qC×L2/12+1.2×(qB-qC)×L2/20=1.94 kN.mMba=1.2×qB×L3/12+1.2×(qA-qB)×L3/30=2.09 kN.mMab=1.2×qB×L3/12+1.2×(qA-qB)×L3/20=2.13 kN.m弯距分配:D点:C点:B点:A点:截面:1000×350 1000×500 1000×500线刚度i=I/L:0.79×1020.83×1020.83×10分配系数μ:0.03;0.97;0.50;0.50 0固端弯距:-129.01;+1.90;-1.94;+2.09;-2.13开始分配:--3.53;--123.58 -0.08;-0.08 00;-0.04;--61.79;0 -0.04+0.02;+0.04;+-30.90;+-30.900;+-15.45;+0.02;0 +-15.45--0.43;--15.02;-0.01;-0.01 00;-0.00;--7.51;0 -0.00支座弯距:∑=-125.03;∑=125.05 ∑=36.40;∑=-28.89 ∑=-17.62简化为Mc=125kN.m Mb=-29kN.m Ma=18kN.m支座调幅0.8后Mc=100kN.m Mb=-23kN.m Ma=14kN.m根据规范公式7.1.4:ξb=0.8÷{1+300÷[20000×(0.0033-<10-50>×10 )]}=0.5692根据规范公式7.2.1-1:受压区高度x=ho-(ho-2*M/α1/fc/b)xc=300-( 300- 2×100×10/1.0/16.7/1000)=18.13mm<ξb×ho=170.77mmxb=450-( 450- 2×-23×10/1.0/16.7/1000)=0.19mm<ξb×ho=256.15mmxa=450-( 450- 2×14×10/1.0/16.7/1000)=0.20mm<ξb×ho=256.15mm根据规范公式7.2.1-2:纵向受拉钢筋As=α1×fc×b×x/fyAsc=1×16.7×1000×18.13/300=1,009mmAsb=1×16.7×1000×0.19/300=10mmAsa=1×16.7×1000×0.20/300=11mm3、裂缝计算:弯距标准值:Mc=125/1.2=104kN.m Mb=-29/1.2=-24kN.m Ma=18/1.2=15kN.m实配钢筋为:负一层16@100钢筋面积As1=2,011mm负二层16@120钢筋面积As2=1,676mm负三层16@100钢筋面积As3=2,011mm带肋钢筋的相对粘结特性系数υ=1.0矩形截面受弯构件,构件受力特征系数αcr =2.1对矩形截面的受弯构件:Ate=0.5×b×h负一层:Ate1=0.5×1000×350=175000mm负二层:Ate2=0.5×1000×500=250000mm负三层:Ate3=0.5×1000×500=250000mm负一层:ρte1=As1/Ate1=2010.6176/175000=0.0115负二层:ρte2=As2/Ate2=1675.51466666667/250000=0.0067负三层:ρte3=As3/Ate3=2010.6176/250000=0.0080纵向受拉钢筋的等效应力σsk=Mk/(0.87×ho×As)负一层:σsk1=104×10/(0.87×300×2,011)=199N/mm负二层:σsk2=-24×10/(0.87×450×1,676)=-37N/mm负三层:σsk3=15×10/(0.87×450×2,011)=19N/mm 钢筋应变不均匀系数ψ=1.1-0.65×ftk/ρte/σsk负一层:ψ1=1.1-0.65×2.2/0.01/199/=0.4732负二层:ψ2=1.1-0.65×2.2/0.01/-37/=4.9965负三层:ψ3=1.1-0.65×2.2/0.01/19/=-6.5645最大裂缝宽度ωmax=αcr×ψ×σsk×(1.9×c+0.08×deq/ρte)/Es负一层:ωmax1=2.1×0.4732×199×(1.9×50+0.08×16/0.01)/200000=0.20mm4、人防计算:本工程负1层为6级人防地下室。

关于人防及外墙计算书

关于人防及外墙计算书

1. 本工程地下二层为甲类防空地下室,人防等级为核6级. 一、人防临空墙计算1、室内出入口等效静荷载为q Q =200k N /㎡ 人防临空墙厚度为300㎜材料强度综合调整系数γl =1.35 混凝土采用C35受力钢筋采用HRB400临空墙短跨方向(主要受力方向)为3.00m 考虑上、下端人防顶板和基础的约束作用 取M =101ql 2 现取宽度1.0m 板带进行计算,保护层厚度为20㎜ M =10200×3.02=180 k N •m 按建筑结构常用数据:A S = 1.35h 3601018006⨯⨯⨯= 1.35270360102.5206⨯⨯⨯=1371.74㎜ 2取C18@150,A S =1696㎜2 人防临空墙配筋:水平分布筋为D14@150 垂直分布筋为D18@150 均满足承载力计算要求。

二、门框墙计算本工程门框墙处均设有暗柱,无端柱门框墙按最大悬挑长度:l 0=700㎜ 防护密闭门门框墙:270k N /㎡,取宽度1.0m 板带进行计算 M =Pl l q 21212+⨯⨯=7.05.02.12702170.0270212⨯÷⨯⨯+⨯⨯=122.85 k N •m A S = 1.35h 3600⨯⨯M = 1.352703601085.1226⨯⨯⨯=936.21㎜2门框墙暗柱箍筋水平筋取:D14@150,满足承载力计算要求。

三、人防外墙计算地下室外墙按单向板计算 取1m 宽进行计算 1、基本资料: 截面宽度b = 1000 (mm) 截面高度h = 250 (mm) 混凝土强度等级 C45 钢筋 III 级 fy= 360 N/mm2计算长度L0= 3.000 m 计算模型为一端固接,一端铰接顶板标高-3 m室外地坪标高-0.45 m地下水位标高-1.85 m底板标高-6 m顶板至室外地坪h1 2.55 m顶板至地下水距离h2 -1.15 m水位至底板h3 4.15 m填土容重γ18 KN/m3浮容重γ’8 KN/m3地面堆载q地面10 KN/m3土内摩擦角φ19.3 °主动土压力系数K0 0.502、荷载计算:a). 土对外墙的侧压力: qt=K0(γ(h1+h2)+γ’h3)=29.3855967 kN/mb). 地下水压力: qs=γ水x h3=41.5 kN/mc). 核爆炸等效静荷载: qe= 60 kN/md). 堆载侧压力qd=K0*q地面=5.0 kN/m3、弯矩及配筋计算:取最大受力点进行计算,故取固端支座B点计算a). 平时状态下计算M=1.2*qtl2/15+1.2*qsl2/15+1.2*qsl2/8=57.83 kN.m钢筋计算fc= 21.1 N/mm2钢筋保护层厚度as 40 mm有效高度ho=h-as-10 =200mmαs=M/(fc*h02)*1000=0.069γ=1/2+1/2*SQRT(1-2*αs)=0.964AS=M/(γ*fy*h0)= 833mm2实际配筋为:Ф16@150 As= 2680 mm2b). 核爆炸作用下计算fy= 486 N/mm2M=1.2*qtl2/15+1.2*qsl2/15+1.2*qsl2/8+1.0*qel2/8= 125.330533 kN.m钢筋计算fc= 21.1 N/mm2调整后fc= 14.3x1.5=31.65N/mm2αs=M/(fc*h02)*1000=0.099γ=1/2+1/2*SQRT(1-2*αs)=0.948AS=M/(γ*fy*h0)=1360 mm2实际配筋为:Ф16@150 As= 2680 mm2跨中最大弯矩近似计算平时状态下计算a). M=1.2*(qt+qs)*l2*0.0298+1.2*qd*9/128= 26.63 kN.m钢筋计算fc= 29.6 N/mm2αs=M/(fc*h02)*1000=0.022γ=1/2+1/2*SQRT(1-2*αs)=0.989AS=M/(γ*fy*h0)=374 mm2实际配筋为:Ф16@150 As= 2680 mm2核爆炸作用下计算fy= 486 N/mm2b). M=1.2*(qt+qs)l2*0.0298+1.0*qel2*9/128+1.2*qd*9/128M= 64.60357857 kN.m钢筋计算fc= 29.6 N/mm2调整后fc= 14.3x1.5= 44.4N/mm2αs=M/(fc*h02)*1000=0.036γ=1/2+1/2*SQRT(1-2*αs)=0.981AS=M/(γ*fy*h0)==677mm2实际配筋为:Ф16@150 As= 2680 mm2三、人防顶板计算LB-1矩形板计算项目名称_____________日期_____________设计者_____________校对者_____________一、构件编号: LB-1二、示意图三、依据规范《建筑结构荷载规范》 GB50009-2001《混凝土结构设计规范》 GB50010-2010四、计算信息1.几何参数计算跨度: Lx = 4500 mm; Ly = 3800 mm板厚: h = 250 mm2.材料信息混凝土等级: C40 fc=19.1N/mm2 ft=1.71N/mm2 ftk=2.39N/mm2 Ec=3.25×104N/mm2钢筋种类: HRB400 fy = 360 N/mm2 Es = 2.0×105 N/mm2最小配筋率: ρ= 0.214%纵向受拉钢筋合力点至近边距离: as = 20mm保护层厚度: c = 10mm3.荷载信息(均布荷载)永久荷载分项系数: γG = 1.200可变荷载分项系数: γQ = 1.000准永久值系数: ψq = 1.350永久荷载标准值: qgk = 12.000kN/m2可变荷载标准值: qqk = 60.000kN/m24.计算方法:弹性板5.边界条件(上端/下端/左端/右端):固定/固定/固定/固定6.设计参数结构重要性系数: γo = 1.00泊松比:μ = 0.200五、计算参数:1.计算板的跨度: Lo = 3800 mm2.计算板的有效高度: ho = h-as=250-20=230 mm六、配筋计算(lx/ly=4500/3800=1.184<2.000 所以按双向板计算):1.X向底板钢筋1) 确定X向板底弯矩Mx = 表中系数(γG*qgk+γQ*qqk)*Lo2= (0.0155+0.0249*0.200)*(1.200*12.000+1.000*60.000)*3.82 = 21.962 kN*m2) 确定计算系数αs = γo*Mx/(α1*fc*b*ho*ho)= 1.00*21.962×106/(1.00*19.1*1000*230*230)= 0.0223) 计算相对受压区高度ξ = 1-sqrt(1-2*αs) = 1-sqrt(1-2*0.022) = 0.0224) 计算受拉钢筋面积As = α1*fc*b*ho*ξ/fy = 1.000*19.1*1000*230*0.022/360= 268mm25) 验算最小配筋率ρ = As/(b*h) = 268/(1000*250) = 0.107%ρ<ρmin = 0.214% 不满足最小配筋要求所以取面积为As = ρmin*b*h = 0.214%*1000*250 = 535 mm2采取方案12@180, 实配面积628 mm22.Y向底板钢筋1) 确定Y向板底弯矩My = 表中系数(γG*qgk+γQ*qqk)*Lo2= (0.0249+0.0155*0.200)*(1.200*12.000+1.000*60.000)*3.82 = 30.050 kN*m2) 确定计算系数αs = γo*My/(α1*fc*b*ho*ho)= 1.00*30.050×106/(1.00*19.1*1000*230*230)= 0.0303) 计算相对受压区高度ξ = 1-sqrt(1-2*αs) = 1-sqrt(1-2*0.030) = 0.0304) 计算受拉钢筋面积As = α1*fc*b*ho*ξ/fy = 1.000*19.1*1000*230*0.030/360 = 368mm25) 验算最小配筋率ρ = As/(b*h) = 368/(1000*250) = 0.147%ρ<ρmin = 0.214% 不满足最小配筋要求所以取面积为As = ρmin*b*h = 0.214%*1000*250 = 535 mm2采取方案12@180, 实配面积628 mm23.X向支座左边钢筋1) 确定左边支座弯矩M o x = 表中系数(γG*qgk+γQ*qqk)*Lo2= 0.0552*(1.200*12.000+1.000*60.000)*3.82= 59.291 kN*m2) 确定计算系数αs = γo*M o x/(α1*fc*b*ho*ho)= 1.00*59.291×106/(1.00*19.1*1000*230*230)= 0.0593) 计算相对受压区高度ξ = 1-sqrt(1-2*αs) = 1-sqrt(1-2*0.059) = 0.0614) 计算受拉钢筋面积As = α1*fc*b*ho*ξ/fy = 1.000*19.1*1000*230*0.061/360 = 738mm25) 验算最小配筋率ρ = As/(b*h) = 738/(1000*250) = 0.295%ρ≥ρmin = 0.214% 满足最小配筋要求采取方案12@180, 实配面积628 mm24.X向支座右边钢筋1) 确定右边支座弯矩M o x = 表中系数(γG*qgk+γQ*qqk)*Lo2= 0.0552*(1.200*12.000+1.000*60.000)*3.82= 59.291 kN*m2) 确定计算系数αs = γo*M o x/(α1*fc*b*ho*ho)= 1.00*59.291×106/(1.00*19.1*1000*230*230)= 0.0593) 计算相对受压区高度ξ = 1-sqrt(1-2*αs) = 1-sqrt(1-2*0.059) = 0.0614) 计算受拉钢筋面积As = α1*fc*b*ho*ξ/fy = 1.000*19.1*1000*230*0.061/360 = 738mm25) 验算最小配筋率ρ = As/(b*h) = 738/(1000*250) = 0.295%ρ≥ρmin = 0.214% 满足最小配筋要求采取方案12@180, 实配面积628 mm25.Y向上边支座钢筋1) 确定上边支座弯矩M o y = 表中系数(γG*qgk+γQ*qqk)*Lo2= 0.0630*(1.200*12.000+1.000*60.000)*3.82= 67.707 kN*m2) 确定计算系数αs = γo*M o y/(α1*fc*b*ho*ho)= 1.00*67.707×106/(1.00*19.1*1000*230*230)= 0.0673) 计算相对受压区高度ξ = 1-sqrt(1-2*αs) = 1-sqrt(1-2*0.067) = 0.0694) 计算受拉钢筋面积As = α1*fc*b*ho*ξ/fy = 1.000*19.1*1000*230*0.069/360 = 847mm25) 验算最小配筋率ρ = As/(b*h) = 847/(1000*250) = 0.339%ρ≥ρmin = 0.214% 满足最小配筋要求采取方案12@180, 实配面积628 mm26.Y向下边支座钢筋1) 确定下边支座弯矩M o y = 表中系数(γG*qgk+γQ*qqk)*Lo2= 0.0630*(1.200*12.000+1.000*60.000)*3.82= 67.707 kN*m2) 确定计算系数αs = γo*M o y/(α1*fc*b*ho*ho)= 1.00*67.707×106/(1.00*19.1*1000*230*230)= 0.0673) 计算相对受压区高度ξ = 1-sqrt(1-2*αs) = 1-sqrt(1-2*0.067) = 0.0694) 计算受拉钢筋面积As = α1*fc*b*ho*ξ/fy = 1.000*19.1*1000*230*0.069/360 = 847mm25) 验算最小配筋率ρ = As/(b*h) = 847/(1000*250) = 0.339%ρ≥ρmin = 0.214% 满足最小配筋要求采取方案12@180, 实配面积628 mm2三、人防底板计算LB-1矩形板计算项目名称_____________日期_____________设计者_____________校对者_____________一、构件编号: LB-1二、示意图三、依据规范《建筑结构荷载规范》 GB50009-2001《混凝土结构设计规范》 GB50010-2010四、计算信息1.几何参数计算跨度: Lx = 4500 mm; Ly = 3800 mm板厚: h = 250 mm2.材料信息混凝土等级: C40 fc=19.1N/mm2 ft=1.71N/mm2 ftk=2.39N/mm2 Ec=3.25×104N/mm2钢筋种类: HRB400 fy = 360 N/mm2 Es = 2.0×105 N/mm2最小配筋率: ρ= 0.214%纵向受拉钢筋合力点至近边距离: as = 20mm保护层厚度: c = 10mm3.荷载信息(均布荷载)永久荷载分项系数: γG = 1.200可变荷载分项系数: γQ = 1.000准永久值系数: ψq = 1.350永久荷载标准值: qgk = 12.000kN/m2可变荷载标准值: qqk = 45.000kN/m24.计算方法:弹性板5.边界条件(上端/下端/左端/右端):固定/固定/固定/固定6.设计参数结构重要性系数: γo = 1.00泊松比:μ = 0.200五、计算参数:1.计算板的跨度: Lo = 3800 mm2.计算板的有效高度: ho = h-as=250-20=230 mm六、配筋计算(lx/ly=4500/3800=1.184<2.000 所以按双向板计算):1.X向底板钢筋1) 确定X向板底弯矩Mx = 表中系数(γG*qgk+γQ*qqk)*Lo2= (0.0155+0.0249*0.200)*(1.200*12.000+1.000*45.000)*3.82 = 17.534 kN*m2) 确定计算系数αs = γo*Mx/(α1*fc*b*ho*ho)= 1.00*17.534×106/(1.00*19.1*1000*230*230)= 0.0173) 计算相对受压区高度ξ = 1-sqrt(1-2*αs) = 1-sqrt(1-2*0.017) = 0.0184) 计算受拉钢筋面积As = α1*fc*b*ho*ξ/fy = 1.000*19.1*1000*230*0.018/360= 214mm25) 验算最小配筋率ρ = As/(b*h) = 214/(1000*250) = 0.085%ρ<ρmin = 0.214% 不满足最小配筋要求所以取面积为As = ρmin*b*h = 0.214%*1000*250 = 535 mm2采取方案10@140, 实配面积560 mm22.Y向底板钢筋1) 确定Y向板底弯矩My = 表中系数(γG*qgk+γQ*qqk)*Lo2= (0.0249+0.0155*0.200)*(1.200*12.000+1.000*45.000)*3.82 = 23.992 kN*m2) 确定计算系数αs = γo*My/(α1*fc*b*ho*ho)= 1.00*23.992×106/(1.00*19.1*1000*230*230)= 0.0243) 计算相对受压区高度ξ = 1-sqrt(1-2*αs) = 1-sqrt(1-2*0.024) = 0.0244) 计算受拉钢筋面积As = α1*fc*b*ho*ξ/fy = 1.000*19.1*1000*230*0.024/360= 293mm25) 验算最小配筋率ρ = As/(b*h) = 293/(1000*250) = 0.117%ρ<ρmin = 0.214% 不满足最小配筋要求所以取面积为As = ρmin*b*h = 0.214%*1000*250 = 535 mm2采取方案10@140, 实配面积560 mm23.X向支座左边钢筋1) 确定左边支座弯矩M o x = 表中系数(γG*qgk+γQ*qqk)*Lo2= 0.0552*(1.200*12.000+1.000*45.000)*3.82= 47.337 kN*m2) 确定计算系数αs = γo*M o x/(α1*fc*b*ho*ho)= 1.00*47.337×106/(1.00*19.1*1000*230*230)= 0.0473) 计算相对受压区高度ξ = 1-sqrt(1-2*αs) = 1-sqrt(1-2*0.047) = 0.0484) 计算受拉钢筋面积As = α1*fc*b*ho*ξ/fy = 1.000*19.1*1000*230*0.048/360 = 586mm25) 验算最小配筋率ρ = As/(b*h) = 586/(1000*250) = 0.234%ρ≥ρmin = 0.214% 满足最小配筋要求采取方案10@130, 实配面积603 mm24.X向支座右边钢筋1) 确定右边支座弯矩M o x = 表中系数(γG*qgk+γQ*qqk)*Lo2= 0.0552*(1.200*12.000+1.000*45.000)*3.82= 47.337 kN*m2) 确定计算系数αs = γo*M o x/(α1*fc*b*ho*ho)= 1.00*47.337×106/(1.00*19.1*1000*230*230)= 0.0473) 计算相对受压区高度ξ = 1-sqrt(1-2*αs) = 1-sqrt(1-2*0.047) = 0.0484) 计算受拉钢筋面积As = α1*fc*b*ho*ξ/fy = 1.000*19.1*1000*230*0.048/360 = 586mm25) 验算最小配筋率ρ = As/(b*h) = 586/(1000*250) = 0.234%ρ≥ρmin = 0.214% 满足最小配筋要求采取方案10@130, 实配面积603 mm25.Y向上边支座钢筋1) 确定上边支座弯矩M o y = 表中系数(γG*qgk+γQ*qqk)*Lo2= 0.0630*(1.200*12.000+1.000*45.000)*3.82= 54.056 kN*m2) 确定计算系数αs = γo*M o y/(α1*fc*b*ho*ho)= 1.00*54.056×106/(1.00*19.1*1000*230*230)= 0.0543) 计算相对受压区高度ξ = 1-sqrt(1-2*αs) = 1-sqrt(1-2*0.054) = 0.0554) 计算受拉钢筋面积As = α1*fc*b*ho*ξ/fy = 1.000*19.1*1000*230*0.055/360 = 671mm25) 验算最小配筋率ρ = As/(b*h) = 671/(1000*250) = 0.269%ρ≥ρmin = 0.214% 满足最小配筋要求采取方案12@160, 实配面积706 mm26.Y向下边支座钢筋1) 确定下边支座弯矩M o y = 表中系数(γG*qgk+γQ*qqk)*Lo2= 0.0630*(1.200*12.000+1.000*45.000)*3.82= 54.056 kN*m2) 确定计算系数αs = γo*M o y/(α1*fc*b*ho*ho)= 1.00*54.056×106/(1.00*19.1*1000*230*230) = 0.0543) 计算相对受压区高度ξ = 1-sqrt(1-2*αs) = 1-sqrt(1-2*0.054) = 0.0554) 计算受拉钢筋面积As = α1*fc*b*ho*ξ/fy = 1.000*19.1*1000*230*0.055/360 = 671mm25) 验算最小配筋率ρ = As/(b*h) = 671/(1000*250) = 0.269%ρ≥ρmi n = 0.214% 满足最小配筋要求采取方案12@160, 实配面积706 mm2。

人防计算书

人防计算书

200厚填充墙线荷〔9×0.2+0.4×2〕×2.5=6.5KN/m 2普通板面荷18×0.01+20×0.02+24×0.04+0.4=1.96取2 KN/m 2卫生间厨房18×0.01+20×0.02+24×0.05+0.4=2.18取2.2 KN/m 2屋面(机房,出屋面楼梯间所在楼面层)为上人屋面。

≥24层,外墙到第二道腰线处以上弯200 门窗洞口宽度为建筑洞宽+40北外墙地下室人防核6常6,顶板q =70 KN/m 2外墙q =40 KN/m 2底板q =55 KN/m 2Q 活=10 KN/m 2Q 活侧=10/19×19×0.4=4 KN/m 2Q 覆土=19×0.875×0.4=6.65 KN/m 2 Q 土水上=19×0.125×0.4=0.95KN/m 2 Q 土水下=11×3.78×0.4=16.632 KN/m 2 Q 水=10×3.78=37.8KN/m 2人防M B K=KNm 245.768905.340822-=⨯=-ql 活M B K=KNm 624.78905.34822-=⨯=-ql 覆土M B K=KNm 676.128905.365.6822-=⨯=-ql 人防M max K=KNm 888.428905.3409128922-=⨯⨯=-ql X =4m 46.18905.3383=⨯=l 活M maxK =KNm 289.4128905.3492=⨯⨯覆土M maz K=KNm 13.7128905.3492=⨯⨯水上土活M B K=KNm 0025.05316125.095.053162222=⎪⎪⎭⎫⎝⎛-⨯-=⎪⎪⎭⎫ ⎝⎛--ααqa 905.3125.0=α R A =()KN ql qb 275.1905.378.34905.3878.395.042323=⎪⎭⎫⎝⎛-⨯⨯=-β m q R a X A 467.1=+= M maz =KNm q R a R A A 015.12=⎪⎪⎭⎫⎝⎛+ 水下土+水 M BK=⎪⎪⎭⎫⎝⎛+-⨯-=⎪⎪⎭⎫ ⎝⎛+--53342478.3432.545334242222ββββqb 96799.0905.378.3==β m qbR b a X A768.12=+=R A =KN l qb 433.1951823=⎪⎭⎫⎝⎛-β M max =KNm qb R b a R A A 713.23232=⎪⎪⎭⎫⎝⎛+ M B =1.35×(12.676+0.0025+1.807+53.737)+0.7×1.4×7.624+76.245=175.8KNmM max =1.35×(7.13+0.0047+1.015+23.713)+0.7×1.4×4.289+42.888=90.1KNm M B K=12.676+0.0025+1.807+53.737+7.624/2=72KNm M max K=7.13+0.0047+1.015+23.713+4.289/2=34KNm M B =175.8KNmC25砼 Ⅲ级钢 f c =16.7 f tk =2.201327.02305.110007.160.1108.17526=⨯⨯⨯⨯⨯=s α 9285.02211=-+=ss αγ2619062303602.19285.0108.175mm A s =⨯⨯⨯⨯=16@100(2015) M max =90.10575.02505.110007.160.1101.9026=⨯⨯⨯⨯⨯=s α9703.02211=-+=ss αγ268602503602.19703.0101.90mm A s =⨯⨯⨯⨯=12/14@150(890)As min =0.25%⨯300⨯1000=0.0134504.00134.093.1782.265.01.1⨯⨯⨯-=ϕmm mm 2.018.00134.01608.0509.110293.178504.01.25<=⎪⎭⎫⎝⎛⨯+⨯⨯⨯⨯⨯=ω以内 26/64.17525089087.01034mm N sk=⨯⨯⨯=σ 286.001.064.1752.265.01.101.0=⨯⨯-==ϕρte mm mm 2.0105.001.01308.0309.110264.175286.01.25<=⎪⎭⎫⎝⎛⨯+⨯⨯⨯⨯⨯=ω次口楼电梯临空墙C35 f c =16.7 &=300 h 0=260M B K=KNm 8.2478905.3130822=⨯=ql M maz =KNm 4.139128905.313092=⨯⨯ 外1463.02605.110007.160.1108.24726=⨯⨯⨯⨯⨯=s α 9205.02211=-+=ss αγ2623972603602.19205.0108.247mm A s =⨯⨯⨯⨯=22@150(2534) &=350外1099.03005.110007.160.1108.24726=⨯⨯⨯⨯⨯=s α 9416.02211=-+=ss αγ2620313003602.19416.0108.247mm A s =⨯⨯⨯⨯=20@150(2095), 18@125(2039)0618.03005.110007.160.1104.13926=⨯⨯⨯⨯⨯=s α968.02211=-+=ss αγ2611123003602.1968.0104.139mm A s =⨯⨯⨯⨯=14/16@150(1183)As min =0.25%⨯350⨯1000=875mm 2 &=300 内0823.02605.110007.160.1104.13926=⨯⨯⨯⨯⨯=s α957.02211=-+=ss αγ2612972603602.1957.0104.139mm A s =⨯⨯⨯⨯=16@150(1340)扩散室临空墙单向板简支KNm qM 8.158.1832=⨯=&=30001.025010005.17.160.1108.1526=⨯⨯⨯⨯⨯=s α 99.02211=-+=ss αγ261482503602.199.0108.15mm A s =⨯⨯⨯⨯=As min =750mm 212@150(1340)上简支,下固定梁式板 12@150 ,四边简支64.0905.35.2==y x l l , 7.195.23902652.0610764.02=⨯⨯⎪⎭⎫ ⎝⎛⨯+=x m6.95.2390764.06102652.02=⨯⨯⎪⎭⎫⎝⎛⨯+=y m12@150扩散室悬板活门临空墙&=300KNm MBK8.2478905.31302-=⨯-=049.045010005.17.160.1108.24726=⨯⨯⨯⨯⨯=s α 9749.02211=-+=ss αγ2613084503602.19749.0108.247mm A s =⨯⨯⨯⨯=As min =0.25%×1000×500=1250mm 2 14@100(1539)四边简支922.025002305==y x l l KNm m x 3.34305.213003606.06104357.02=⨯⨯⎪⎭⎫ ⎝⎛⨯+=KNm m y 9.29305.213004357.06103606.02=⨯⨯⎪⎭⎫⎝⎛⨯+=通道(人防主口) 侧墙:&=300上水q 水上=10×2.9=29 下水q 水下=10×3.45=34.5水上土q 土水上=19×0.75×0.4=5.7 水下土q 土水下=11×2.9×0.4=12.767 侧土q 侧土=11×3.45×0.4=15.18 活q 活=10×0.4=4 人防q 防=4085.345.3=α 1039.085.34.0==β49.675.1418.155.34523=⎪⎪⎭⎫ ⎝⎛+=αβqa R A ⎪⎭⎫ ⎝⎛-=52122αqa R A6.1547.3518.155.34531222--=⎪⎪⎭⎫⎝⎛--=αqa M B 214.1==qaR ax A 26.594.1118.155.34232max ==qa R Ra M A()4.1822.881.4167.5777.576.127.5294046883=+-=ααqa R A ()2268α-=qa R B()72.2215.1065.5124.7112.776.127.5294042822-----=--=αqa M B m qR x A44.1==27.1393.514.3057.4116.476.127.5294042max 2=-=g R M A()KNm M B K 39.21056.383.206212.772.2265.5124.7147.356.15=--=-++++-=C35 f c =16.7 &=300 h 0=230mm1588.023010005.17.160.11039.21026=⨯⨯⨯⨯⨯=s α 913.02211=-+=ss αγ2623202303602.1913.01039.210mm A s =⨯⨯⨯⨯=18@100(2545) &=350 h 0=270mm1152.027010005.17.160.11039.21026=⨯⨯⨯⨯⨯=s α9386.02211=-+=ss αγ2619222703602.19386.01039.210mm A s =⨯⨯⨯⨯=16@100(2011)()KNm M B 02.19012.70.7 4.172.2215.1065.5147.356.1535.1-=⨯⨯-++++⨯-=1561.027010005.17.160.11002.19026=⨯⨯⨯⨯⨯=s α 915.02211=-+=ss αγ2621382703602.1915.01002.190mm A s =⨯⨯⨯⨯=KNm M B K 15.139-=26/57.294201127087.01015.139mm N s ⨯⨯⨯=σ0145.010003505.02545=⨯⨯=te ρ6775.00145.076.2322.265.01.1=⨯⨯-=ψ3.00145.01608.0509.110276.2326775.01.25=⎪⎭⎫⎝⎛⨯+⨯⨯⨯⨯⨯=ω &=400 h 0=320mm1561.032010005.17.160.11002.19026=⨯⨯⨯⨯⨯=s α 941.02211=-+=ss αγ261753320360941.01002.190mm A s =⨯⨯⨯=选用 16@100(2011)0145.010004005.02011=⨯⨯=te ρ525.001.05.2482.265.01.1=⨯⨯-=ψ31.001.01608.0509.11025.248525.01.25=⎪⎭⎫⎝⎛⨯+⨯⨯⨯⨯⨯=ω 26/5.248201132087.01015.139mm N sk ⨯⨯⨯=σ选用 18@100(2545)26/4.196254532087.01015.139mm N sk⨯⨯⨯=σ 0127.010004005.02454=⨯⨯=te ρ528.00127.04.1962.265.01.1=⨯⨯-=ψ23.00127.01808.0509.11024.196528.01.25=⎪⎭⎫⎝⎛⨯+⨯⨯⨯⨯⨯=ω 人防配筋&=400 M B =210.39082.032010005.17.160.11039.21026=⨯⨯⨯⨯⨯=s α 957.02211=-+=ss αγ2615913202.1360957.01039.210mm A s =⨯⨯⨯⨯=KNm M 19.11008.211.108216.427.1393.514.3057.4126.594.11max =+=++++++=防0359.035010005.17.160.11019.11026=⨯⨯⨯⨯⨯=s α 98.02211=-+=ss αγ1000%25.07443502.136098.01019.11026=<=⨯⨯⨯⨯=bh mm A s取 16@200()KNmM 91.9316.498.027.1393.514.3026.594.1135.1max =⨯+++++⨯=0459.035010007.160.11091.9326=⨯⨯⨯⨯=s α9765.02211=-+=ss αγ267643503609765.01091.93mm A s =⨯⨯⨯=26/43.217100535087.01054.66mm N sk =⨯⨯⨯=σ 01.0=te ρ4423.001.043.2712.265.01.1=⨯⨯-=ψ mm mm 2.019.001.01608.0209.110243.2174423.01.25<=⎪⎭⎫ ⎝⎛⨯+⨯⨯⨯⨯⨯=ω。

人防及通风计算书-暖通

人防及通风计算书-暖通

人防及通风计算书-暖通地下室人防及通风计算书一.平时风量计算:本工程地下室汽车库建筑面积16130.92㎡,为八个防火分区。

其中防火分区一、防火分区二、防火分区三均为汽车库;防火分区四与防火分区六为设备用房;防火分区五、防火分区七以及防火分区八平时为自行车库,战时为二等人员掩蔽场所,分为两个防护单元(防火分区五为一个防护单元,防火分区七与防火分区八为一个防护单元),防护等级均为甲类核六级、常六级,防化等级均为丙级,人防部分面积为4320.7㎡.汽车库可停放汽车325辆。

汽车库平时排风系统与火灾排烟系统合用,排风机兼排烟风机。

平时排风量、排烟量均按换气次数6次/h计算。

汽车库平时排风,由机械补风和汽车坡道进行自然补风。

火灾时,排烟风机继续运行排烟,其它与消防无关通风设备关闭,此时补风方式采用机械补风,补风量不小于总排烟量的50%。

自行车库平时通风以及消防排烟参照汽车库相关规范执行,按换气次数为6次/h计算。

设置机械补风,补风量不小于总排烟量的50%。

一)人防地下室车库通风计算:人防非机动车库为三个防火分区,四个防烟分区。

面积分别为1057㎡、714㎡、922㎡、955㎡。

板下净高3.5m。

①排风、排烟量:L=1.1x(1057+714)x3.5x6=40910CMH选用风机:PYHL3-2A NO.9.5A 41000CMH 650Pa 11KW 535Kg 83dB排风机单位风量耗功率:Ws=650/(3600x0.6)=0.3W/(m^3/h)补风:按不小于50%取值,所选风机为HL3-2A NO.9A 23618CMH 362Pa 4KW 460Kg 75dB Ws=0.213②排风、排烟量:L=1.1x922x3.5x6=21298CMH选用风机:PYHL-14A NO.8A 22000CMH 540Pa 5.5KW 363Kg75dB排风机单位风量耗功率:Ws=540/(3600x0.6)=0.25W/(m^3/h)补风:按不小于50%取值,所选风机为HL-14A NO.7.5A 13668CMH 251Pa 2.2KW 295Kg 67dB Ws=0.116③排风、排烟量:L=1.1x922x3.5x6=21298CMH选用风机:PYHL-14A NO.8A 22000CMH 540Pa 5.5KW 363Kg 75dB排风机单位风量耗功率:Ws=540/(3600x0.6)=0.25W/(m^3/h)补风:按不小于50%取值,所选风机为HL-14A NO.7.5A 13668CMH 251Pa 2.2KW 295Kg 67dB Ws=0.116二.战时风量计算:战时为核6级二等人员掩蔽部,分两个防护单元。

人防计算书

人防计算书

杭州中翰建筑设计有限公司结构计算书工程编号:工程名称:项目名称: xx区地下汽车库设计阶段: xx区人防结构计算计算人:校对人:专业负责:审核人:日期: 2012.03Ⅶ区地下汽车库人防结构计算书目录一、人防主要计算依据和计算软件二、人防等效荷载及材料强度三、主要人防墙体计算(一)人防临空墙(二)非人防与人防隔墙(三)相邻人防单元隔墙(四)人防扩散室隔墙(五)人防地下室外墙四、各类门框墙、楼梯等按图集选用五、人防地下室梁、柱计算(SATWE电算)六、人防地下室顶板和底板计算(SATWE电算)人防结构计算一、主要计算依据和计算软件1、《人民防空地下室设计规范》 GB50038-20052、《防空地下室结构设计》(国家建筑标准设计图集) 07FG01~053、《防空地下室》(全国民用建筑工程设计技术措施) 20094、计算软件PKPM(2012版)A人防侧墙、临空墙、单元隔墙采用手算并结合结构计算软件Morgain 2012年版计算。

人防门框墙、扩散室悬板活门门框墙、防暴波电缆井、室外主要出入口人防楼梯等,依据国标人防图集查选。

B人防底板和顶板采用PKPM-PMCAD程序计算C人防地下室柱、地梁、顶板的梁采用PKPM-Satwe程序计算二、等效静荷载及材料强度1、本工程为甲类防空地下室,人防等级核6级常6级,人防区为大地下室Ⅶ区范围,共5个人防防护单元2、人防等效静荷载标准值确定:依据《人民防空地下室设计规范GB 50038—2005》查表,人防构件允许延性比按4.6.2条规定。

a、顶板:(梁板结构,允许延性比3.0)《规范》4.8.2条1)纯地下室部分:70kPa (不考虑上部建筑影响,覆土1.5米,板区格最大短边净跨5.7米-0.3米=5.4米)2)主楼范围地下室(-2.8米标高板):55kPa(考虑上部建筑影响,无覆土,板净跨≥3米0029b、土中外墙:(允许延性比2.0)《规范》4.8.3-2条不考虑上部建筑影响,取55kPa (饱和土中,淤泥土)c、带桩基钢筋混凝土底板,第4.8.15条,取值25kPad、相邻防护单元间隔墙,门框墙:1)6级与6级相邻每侧:50kPa2)6级与普通地下室普通地下室一侧:隔墙:110kPa ;门框墙:170kPa3)扩散室与与内部房间相邻的临空墙:39kPae、楼梯踏步与休息平台(作为战时主要出入口):正面荷载:60 kPa 反面荷载:30 kPaf、出入口直接作用门框墙和出入口临空墙:(kPa)三、主要人防墙体计算:(一)、地下室墙计算:DFQ1(人防临空墙)人防等效静荷载标准值:130kN/m2 (按均布荷载输入Morgain)混凝土强度等级为 C35,人防:f c= 16.72N/mm2x1.5=25.08 N/mm2f t= 1.575N/mm2x1.5=2.363 N/mm2f tk= 2.204N/mm2x1.5=3.306 N/mm2Ec=3.15x104 N/mm2x1.2=3.78 x104 N/mm2钢筋抗拉强度设计值(HRB400) f y= 360N/mm2x1.2=432 N/mm2E s= 20 x104 N/mm2Morgain计算如下:上下固端,不考虑裂缝控制。

人防计算书

人防计算书

人防设计计算书人防计算书一、设计依据《人民防空地下室设计规范》GB50038-2005《建筑地基基础设计规范》GB50007-2011《混凝土结构设计规范》GB50010-2010《建筑抗震设计规范》GB50011-2010(2016版)二、荷载取值人防工程为地下两层,层高均为3.6m,地下二层为甲类核6级,常6级物资库,地下一层为甲类核6级,常6级二等人员掩蔽所,荷载根据《人民防空地下室设计规范》GB50038-2005取值,按承受常规武器爆炸动荷载、核武器爆炸动荷载、静荷载组合分别作用设计,并取最不利组合配筋。

三、材料墙、柱混凝土采用C35,梁、板采用C35混凝土,钢筋:采用HRB400级。

四、结构体系本工程采用钢筋混凝土框架结构,外墙、临空墙、隔墙等采用钢筋混凝土墙体,基础采用桩基础,地下室底板为桩基础防水板,地下室顶楼盖采用无梁楼盖体系,梁、板、墙、底板构件尺寸详见图纸。

五:设计方法人防楼板及梁柱配筋采用盈建科1.8.2版,输入相应荷载进行设计。

地下室外墙,临空墙,人防隔墙等采用理正,scct等结构计算软件,按相应人防荷载进行设计。

因每层净高均小于 3.6m,门框墙根据图集《防空地下室结构设计》FG01~05进行选取。

竖井,防爆波电缆井,人防楼梯,放倒塌棚架等根据《防空地下室结构设计》FG01~05进行选取。

六:构件计算LKQ1临空墙计算3600x3600mm,双向板一、计算条件:工程名称: 工程一工程项目: 项目一临空墙编号: LKQ1临空墙的宽度L x(mm): 3600临空墙的高度L y(mm): 3600临空墙的厚度t(mm): 300临空墙等效静荷载q e(kN/m2): 160临空墙保护层厚度c(mm): 20临空墙混凝土强度等级: C35临空墙钢筋级别: HRB400内力计算采用弹性方法: 否临空墙最小配筋率(%): 0.25动荷载下构件允许延性比[ ]: 1.0进行斜截面抗剪验算: 是进行抗冲切验算: 是二、计算依据:《混凝土结构设计规范》GB50010-2010《建筑结构荷载规范》GB50009-2012《建筑结构静力计算实用手册》浙江大学编写,中国建筑工业出版社出版三、计算结果:(1)系数说明:Mx,Mxmax分别为平行于Lx方向板中心点的弯矩和板跨内最大弯矩;My,Mymax分别为平行于Ly方向板中心点的弯矩和板跨内最大弯矩;Mxo,Myo分别为固定边中点沿Lx和Ly方向的支座弯矩;(2)(3)(4)人防组合下,板斜截面抗剪计算过程如下:V = [q × (2 × Ly-Lx) × Lx / (4 × Ly)] / 1000= [160.00 × (2 × 3600 - 3600) × 3600 / (4 × 3600)] / 1000 = 144.00 kN混凝土轴心受压强度设计值:f t = 1.43 N/mm2混凝土材料综合调整系数:γd = 1.50调整后的混凝土轴心受压强度设计值: f td = f t × γd × 0.8 = 1.43 × 1.50 × 0.8 = 1.72 N/mm2截面有效高度: H0 = H-c- 10 = 300 - 20 - 10 = 270 mmβh = 1截面抗剪承载力: R = 0.7 × βh × f td × H0 = 0.7 × 1.0000 × 1.72 × 270 = 324.32 kN人防组合下, V ≤ 0.7 × βh × f td × H0 , 板斜截面抗剪验算满足要求!(5)人防组合下,板抗冲切计算过程如下:人防组合面荷载值:q = 160 kN/m2混凝土抗拉强度:f t = 1.43 N/mm2调整后的混凝土抗拉强度: f td = f t × r d = 1.43 × 1.50 = 1.72 N/mm2H0 = H-c1- 8 = 300 - 20 - 8 = 272 mmβh = 1F L = q × (Lx- 2 × H) × (Ly- 2 × H) / 1000000= 160.00 × (3600 - 2 × 300) × (3600 - 2 × 300) / 1000000 = 1440.00 kN u m = (Lx-H) × 2 + (Ly-H) × 2 = (3600 - 300) × 2 + (3600 - 300) × 2 = 13200 mmR = 0.7 × βh × f td × u m × H0 / 1000= 0.7 × 1.00 × 2.15 × 13200 × 272 / 1000 = 5390.99 kN人防组合下, F L ≤ 0.7 × βh × f t × u m × H0 , 板抗冲切验算满足要求!LKQ2 临空墙计算7200x3600 双向板一、计算条件:工程名称: 工程一工程项目: 项目一临空墙编号: LKQ1临空墙的宽度L x(mm): 7200临空墙的高度L y(mm): 3600临空墙的厚度t(mm): 300临空墙等效静荷载q e(kN/m2): 160临空墙保护层厚度c(mm): 20临空墙混凝土强度等级: C35临空墙钢筋级别: HRB400内力计算采用弹性方法: 否临空墙最小配筋率(%): 0.25动荷载下构件允许延性比[β]: 1.0进行斜截面抗剪验算: 是进行抗冲切验算: 是二、计算依据:《混凝土结构设计规范》GB50010-2010《建筑结构荷载规范》GB50009-2012《建筑结构静力计算实用手册》浙江大学编写,中国建筑工业出版社出版三、计算结果:(1)系数说明:Mx,Mxmax分别为平行于Lx方向板中心点的弯矩和板跨内最大弯矩;My,Mymax分别为平行于Ly方向板中心点的弯矩和板跨内最大弯矩;Mxo,Myo分别为固定边中点沿Lx和Ly方向的支座弯矩;(2)(3)(4)人防组合下,板斜截面抗剪计算过程如下:V = [q × (2 × Lx-Ly) × Ly / (4 × Lx)] / 1000= [160.00 × (2 × 7200 - 3600) × 3600 / (4 × 7200)] / 1000 = 216.00 kN混凝土轴心受压强度设计值:f t = 1.43 N/mm2混凝土材料综合调整系数:γd = 1.50调整后的混凝土轴心受压强度设计值: f td = f t × γd × 0.8 = 1.43 × 1.50 × 0.8 = 1.72 N/mm2截面有效高度: H0 = H-c- 10 = 300 - 20 - 10 = 270 mmβh = 1截面抗剪承载力: R = 0.7 × βh × f td × H0 = 0.7 × 1.0000 × 1.72 × 270 = 324.32 kN人防组合下, V ≤ 0.7 × βh × f td × H0 , 板斜截面抗剪验算满足要求!(5)人防组合下,板抗冲切计算过程如下:人防组合面荷载值:q = 160 kN/m2混凝土抗拉强度:f t = 1.43 N/mm2调整后的混凝土抗拉强度: f td = f t × r d = 1.43 × 1.50 = 1.72 N/mm2H0 = H-c1- 8 = 300 - 20 - 8 = 272 mmβh = 1F L = q × (Lx- 2 × H) × (Ly- 2 × H) / 1000000= 160.00 × (7200 - 2 × 300) × (3600 - 2 × 300) / 1000000 = 3168.00 kNu m = (Lx-H) × 2 + (Ly-H) × 2 = (7200 - 300) × 2 + (3600 - 300) × 2 = 20400 mmR = 0.7 × βh × f td × u m × H0 / 1000= 0.7 × 1.00 × 2.15 × 20400 × 272 / 1000 = 8331.52 kN人防组合下, F L ≤ 0.7 × βh × f t × u m × H0 , 板抗冲切验算满足要求!LKQ3 临空墙计算单向板本计算依据《人民防空地下室设计规范》GB50038-2005简称《规范》,其余规范按国家统一标准。

人防地下室墙体计算书

人防地下室墙体计算书

WQ1地下室侧壁计算书条件:1、土质参数:容重γ=18kN/mmγ` = 11kN/mm K=0.50,地下水位设防高度为5100mm;2、地下室参数:覆土层厚h1=1000mm,地下室侧墙计算跨度Lo=4800mm,临水面保护层为40mm;地面堆载q=10kN/mm d=350mm,截面有效高度ho=300mm3、材料参数:混凝土强度等级为C35,fc=16.7 N/mm fy=360N/mm 计算:1、荷载计算,土压力按静止土压力计算[《全国民用建筑工程设计技术措施》2.6.2]堆载折算为土压力q1=K×q=0.50×10=5.00kN/mm地下水位以上土压力q2=K×γ×h1=0.50×18×1.00=9.00kN/mm地下水位以下土压力q3=K×γ`×(h2 + h3)=0.50×11×(0.30+4.80)=28.05kN/mm水压力q4=γw×(h2 + h3)=10×(0.30+4.80)=51.00kN/mm2、支座弯距计算,按单向板底端固定顶端简支计算,查静力计算手册m1=q1×Lo/8=5.00×4.8/8=14.40kN.mm2=q2×Lo/15=9.00×4.8/15=13.82kN.mm3=q1×Lo/15=28.05×4.8/15=43.08kN.mm4=q1×Lo/8=51.00×4.8/15=78.34kN.m3、强度计算:土压力及水压力均按恒载考虑,[《全国民用建筑工程设计技术措施》2.6.2],按支座调幅计算m=0.80×1.35×(m1+m2+m3+m4)=161.62kN.mξb=0.8÷{1+360÷[20000×(0.0033-<35-50>×0.00001)]}=0.5257 《砼》规公式7.1.4x=ho-√(ho-2×m/α1/fc/b)=300-√(300-2×161.62×1000000/1/16.7/1000) 《砼》规公式7.2.1-1=34.21mm<ξb×ho=157.71mmAs=α1×fc×b×x/fy 《砼》规公式7.2.1-2=1×16.7×1000×34.21/360=1,587mm4、裂缝计算:弯距标准组合Mk=m1+m2+m3+m4=14.40+13.82+43.08+78.34=149.64kN.m实配钢筋为:18@75钢筋面积As=3,393mm带肋钢筋的相对粘结特性系数υ=1.0矩形截面受弯构件,构件受力特征系数αcr =2.1对矩形截面的受弯构件:Ate=0.5×b×h=0.5×1000×300=175000mmρte=As/Ate=3,393/175000=0.0194纵向受拉钢筋的等效应力σsk=Mk/(0.87×ho×As)=150×1000000/(0.87×300×3,393)=169 N/mm 钢筋应变不均匀系数ψ=1.1-0.65×ftk/ρte/σsk=1.1-0.65×2.2/0.02/169/=0.6635最大裂缝宽度ωmax=αcr×ψ×σsk×(1.9×c+0.08×deq/ρte)/Es=2.1×0.6635×169×(1.9×40+0.08×18/0.02)/200000=0.1769mm5、人防计算:本工程为6级人防地下室。

人防计算书

人防计算书

0.5
实际重量取值。
0.6
2)覆土容重:
18kN/m2
3)设备荷载按实际
常 6 级等效静载荷载确定 备注
40载(32) 25 / 285
50 或 0 167
50 或 0 /
1)其它荷载按 (GB50038-2005 )规定取值。 2)核爆炸等效静 载与常规武器爆 炸等效静载两者 取大值
3-2 地下室外墙荷载组合计算 A) 地下室外墙 WQI
部位
顶板
侧墙
底板
有/无桩基础
门框墙
室外直接作用的门框墙 室内出入口门框墙
临空墙
室外直接作用的临空墙 室内出入口临空墙
普通地下室与防护单元门框墙/隔墙
核 6 级等效静载
60(55) 45/55 25/50 240 200 160 130 170/90
准永久值
备注
0.3
1)未注明荷载均按
0.5
有关规定、规程或按
左 -136.4
[配筋结果]
轴压比:
N/(A*fc)= 0
竖直方向配筋(mm^2/m):
[注意: 配筋小于0表示超筋, 荷载作用面为外侧]
上截面: 非荷载侧= 0 荷载侧= 1528(mm^2/m)
中截面: 非荷载侧= 627 荷载侧= 0(mm^2/m)
下截面: 非荷载侧= 0 荷载侧= 15284.269
中 87.044
0.000 -36.375
右 0.000 -166.314 -238.467
上部纵筋:
600
600
下部纵筋:
600
976
箍 筋:
953
953
-------------------------------------------------------------------
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

XXXXXX工程人防地下室计算书目录目录 (1)工程概况 (3)二、主要设计规范及标准 (3)三、结构设计计算书 (3)2.1顶板 (3)2.1.1恒荷载 (3)2.1.2活荷载 (3)2.1.3 战时荷载 (3)2.1.4 顶板计算 (4)2.2梁 (6)2.2.1符号说明 (6)2.2.2内力计算及配筋 (7)2.3柱 (12)2.3.1符号说明 (12)2.3.2内力计算及配筋 (14)2.4侧壁 (15)2.5底板 (20)2.6基础计算 (22)2.6.1荷载组合公式 (22)2.6.2符号说明: (24)2.6.3内力及配筋 (24)四、地下室抗浮验算 (29)工程概况本工程建筑结构为框架结构,地上三层,地下一层。

建筑总高度11.7米,结构安全等级二级,设计使用年限50年。

地下一层为平战结合人防地下室工程,人防地下室防核武器抗力级别为6级,防常规武器抗力级别为6级。

地下室采用现浇混凝土梁板式结构。

地下室外墙、梁、柱混凝土强度等级为C35,其它构件混凝土等级为C30。

基础采用独立基础形式,地基载力特征值140KN ,本工程地下水位较深,故不需考虑底板抗浮设计。

二、主要设计规范及标准《建筑结构荷载规范》(GB50009—2002)《混凝土结构设计规范》(GB50010—2002)《人民防空地下室设计规范》(GB50038—2005)《建筑地基基础技术规范》(DB21/907-2005)《建筑抗震设计规范》(GB 50011-2010)三、结构设计计算书2.1顶板2.1.1恒荷载覆土自重:(覆土厚度1000mm )20× 1=20.02/kn m 。

2.1.2活荷载室内顶板取3.02/kn m 。

2.1.3 战时荷载常规武器爆炸在地下室顶板产生的等效静荷载标准值(《人民防空地下室设计规范》GB50038-2005 以下简称《人防规范》4.7.2条)覆土1.2米1ce q =402/kn m核武器爆炸时在地下室顶板产生的等效静荷载标准值(《人防规范》4.8.2条)覆土1.2米1e q =752/kn m综合上述,顶板战时荷载取752/kn m2.1.4 顶板计算该部分计算采用SATWE 计算,分为两个模型,模型一不计算人防荷载,模型二计算人防荷载,取二者的大值配筋。

(1)构件截面尺寸详见结构施工图(2)战时构件内力计算及配筋计算条件:板长 = 3600.00(mm) 板宽 = 3250.00(mm) 板厚 = 250.00(mm)均布荷载(KN/M2): 75.00砼强度等级: C30配筋计算 as(mm): 30钢筋级别 : HRB400支撑条件:上边 下边 左边 右边固定 固定 固定 固定-44.10-44.10-40.88-40.8815.4518.5562562562562562562562562562562562562570.033003600冲切验算:周边墙厚按 300.0 (mm) 计算冲切力 Q = q0 * (lx - 2t - tw)*(ly -2t - tw)= 70.00 * 2.80 * 2.50= 490.00(kN)抗冲切力 Fl = 0.7 * βh * ft * um * h0= 0.7 *1.00 *2149.34 *11.60 *0.23= 4014.10 kN∴ FL > Q 冲切验算满足。

配筋计算:跨中弯矩(kN-m/m):水平:15.45 竖向:18.55跨中弯矩配筋(mm^2/m):上水平:625.00 竖向:625.00下水平:625.06 竖向:625.06支座弯矩(kN-m/m):上下左右-44.10 -44.10 -40.88 -40.88支座弯矩配筋(mm^2/m):上下左右上 625.06 625.06 625.06 625.06下 625.06 625.06 625.06 625.062.2梁2.2.1符号说明B,H --- 矩形截面宽、高(mm) Dr --- 圆柱直径(mm) B,H,U,T,D,F --- 异型截面参数(mm) U1,T1,D1,F1 --- 另一方向工字钢截面参数(mm) Hr --- 变截面时梁右端(柱为上端)高度(mm) Ac --- 截面面积(mm) Lc,Lg,Lwc,Lwb,Lb --- 分别为柱、支撑、墙柱、墙梁和梁的长度(m) N-C,N-G,N-WC,N-WB,N-B --- 分别为柱、支撑、墙柱、墙梁和梁的单元号Nfc,Nfg,Nfw,Nfwb,Nfb --- 分别为柱、支撑、墙柱、墙梁和梁的抗震等级 Nfc_kzgz,Nfg_kzgz,Nfw_kzgz,Nfwb_kzgz,Nfb_kzgz --- 分别为柱、支撑、墙柱、墙梁和梁的抗震构造措施采用的抗震等级Rcc,Rcg,Rcw,Rcwb,Rcb --- 分别为柱、支撑、墙柱、墙梁和梁的材料强度 Rsc,Rsg,Rsb --- 分别为柱、支撑和梁的钢号或复合截面的钢号Cover --- 保护层厚度(mm) Fy,Fyv --- 为构件的主筋、箍筋(墙柱为分布筋)强度设计值(Icn) --- 控制内力的内力组合号LoadCase --- 控制梁内力包络的组合号矩形(型钢)混凝土梁配筋输出符号说明:I,J --- 代表梁左、右端支座截面1,2,3,4,5,6,7 --- 代表梁跨中从左到右7个等分截面-M,+M --- 负、正弯矩包络(kN-m) Top_Ast,Btm_Ast --- 负、正弯矩的配筋包络(mm) %_Steel --- 负、正弯矩配筋的配筋率Shear --- 剪力包络(kN) Asv --- 抗剪之最小箍筋包络(mm) Rsv --- 抗剪箍筋的配筋率(Icn)Tmax&Shear --- 最大剪扭配筋的控制扭矩和剪力(kN-m,kN) Astt --- 剪扭配筋之纵筋面积(mm) Astv --- 剪扭配筋之箍筋面积(mm) Ast1 --- 剪扭配筋之纯扭双肢箍的单根箍筋面积(mm) Nmax --- 最大轴力(受拉为正)(kN) 注:梁箍筋是指间距Sb范围内的箍筋面积荷载组合分项系数说明,其中:Ncm --- 组合号V-D,V-L --- 分别为恒载、活载分项系数X-W,Y-W --- 分别为X向、Y向水平风荷载分项系数X-E,Y-E --- 分别为X向、Y向水平地震荷载分项系数Z-E --- 为竖向地震荷载分项系数R-F --- 为人防荷载分项系数2.2.2内力计算及配筋KL1:KL1= 1 (I= 487, J= 488) ( 1)B*H(mm)= 350* 750Lb= 3.25 Cover= 30 Nfb= 2 Rcb= 35.0 Fy= 360*0.5. Fyv= 300*1.5.调幅系数:0.85 扭矩折减系数:1.00 刚度系数:0.60梁属性:混凝土梁不调幅梁连梁-I- -1- -2- -3- -4- -5- -6- -7- -J- -M(kNm) 0. 0. 0. 0. 0. -22. -345. -714. -1095. LoadCase ( 0) ( 0) ( 0) ( 0) ( 0) ( 34) ( 36) ( 36) ( 36) Top Ast 2141. 1430. 656. 656. 656. 656. 1200. 2492. 4013. % Steel 0.82 0.54 0.25 0.25 0.25 0.25 0.48 1.01 1.68 +M(kNm) 1217. 1020. 811. 578. 311. 33. 17. 9. 0. LoadCase ( 36) ( 36) ( 36) ( 36) ( 36) ( 31) ( 0) ( 0) ( 0) Btm Ast 4452. 3741. 2988. 2013. 1081. 656. 656. 656. 1702. % Steel 1.86 1.57 1.25 0.81 0.44 0.25 0.25 0.25 0.65 Shear -478. -495. -539. -612. -711. -811. -884. -928. -945. LoadCase ( 36) ( 36) ( 36) ( 36) ( 36) ( 36) ( 36) ( 36) ( 36) Asv 74. 80. 96. 122. 158. 194. 220. 236. 242. Rsv 0.21 0.23 0.28 0.35 0.45 0.55 0.63 0.67 0.69 Tmax/Shear( 1)= 0.6/ -190. Astt= 0. Astv= 73.5 Ast1= 0.0非加密区箍筋面积(1.5H处) Asvm= 200.0具体配筋见结构施工图。

KL2:KL2= 2 (I= 473, J= 489) ( 1)B*H(mm)= 400* 900Lb= 3.25 Cover= 30 Nfb= 2 Rcb= 35.0 Fy= 360*1.5. Fyv= 300*1.5.调幅系数:0.85 扭矩折减系数:0.40 刚度系数:1.00梁属性:混凝土梁框架梁调幅梁-I- -1- -2- -3- -4- -5- -6- -7- -J- -M(kNm) 0. 0. 0. 0. 0. -35. -470. -954. -1455. LoadCase ( 0) ( 0) ( 0) ( 0) ( 0) ( 28) ( 36) ( 36) ( 36) Top Ast 900. 900. 900. 900. 900. 900. 1334. 2708. 4383. % Steel 0.25 0.25 0.25 0.25 0.25 0.25 0.39 0.79 1.32+M(kNm) 1554. 1303. 1035. 733. 385. 32. 24. 13. 0. LoadCase ( 36) ( 36) ( 36) ( 36) ( 36) ( 0) ( 0) ( 0) ( 0) Btm Ast 4749. 3902. 2942. 2083. 1092. 900. 900. 900. 1080. % Steel 1.43 1.17 0.86 0.61 0.32 0.25 0.25 0.25 0.30 Shear -549. -571. -627. -717. -836. -954. -1044. -1100. -1122. LoadCase ( 36) ( 36) ( 36) ( 36) ( 36) ( 36) ( 36) ( 36) ( 36) Asv 84. 84. 84. 100. 135. 171. 197. 214. 220. Rsv 0.21 0.21 0.21 0.25 0.34 0.43 0.49 0.53 0.55 Tmax/Shear( 1)= 2.6/ -235. Astt= 0. Astv= 84.0 Ast1= 0.0非加密区箍筋面积(1.5H处) Asvm= 170.6具体配筋见结构施工图。

相关文档