腔镜清洗消毒流程
腹腔镜器械手工清洗操作流程及质量标准

腹腔镜器械手工清洗操作流程及质量标准下载提示:该文档是本店铺精心编制而成的,希望大家下载后,能够帮助大家解决实际问题。
文档下载后可定制修改,请根据实际需要进行调整和使用,谢谢!本店铺为大家提供各种类型的实用资料,如教育随笔、日记赏析、句子摘抄、古诗大全、经典美文、话题作文、工作总结、词语解析、文案摘录、其他资料等等,想了解不同资料格式和写法,敬请关注!Download tips: This document is carefully compiled by this editor. I hope that after you download it, it can help you solve practical problems. The document can be customized and modified after downloading, please adjust and use it according to actual needs, thank you! In addition, this shop provides you with various types of practical materials, such as educational essays, diary appreciation, sentence excerpts, ancient poems, classic articles, topic composition, work summary, word parsing, copy excerpts, other materials and so on, want to know different data formats and writing methods, please pay attention!腹腔镜器械手工清洗操作流程及质量标准引言腹腔镜手术在现代医学中被广泛应用,而清洁、消毒腹腔镜器械则是保证手术安全和成功的重要环节。
腔镜器械的清洗消毒操作流程

腔镜器械的清洗消毒操作流程腹腔镜器械手术操作后会附有大量的有机物,血液、粘液、分泌物等。
有机物的污染凝固,会生锈腐蚀器械,造成器械过早报废,增加医院成本。
再次,有机物的污染包含有大量的病原体及致热源,如器械清洗不到位,残留物会导致灭菌失败,直接影响患者的健康、甚至生命安全。
因此腔镜器械的清洗消毒质量的保证,不仅可以减少器械锈蚀,延长器械寿命,也是灭菌成功的前提,是控制医院感染的重要环节。
我院为保证腹腔镜器械的灭菌质量和医疗安全,对腔镜器械的清洗消毒实行了规范的规章制度,责任明确,分工明确。
由于腔镜器械种类繁多结构复杂,且工艺精细、贵重。
我院对腹腔镜器械的清洗方法选择人工清洗加超声清洁。
任何制度和标准都需要通过从业人员来实施,专业技能和工作态度将决定腔镜器械的清洗效果。
腔镜器械按排专门人员清洗,责任制到个人,可以提高工作质量和效率。
还有对专门清洗腔镜器械的人进行专业的培训和严格的考核,以提高工作质量和效率,确保制度的有效落实和各项标准的严格检验,使腔镜器械的清洗消毒质量和灭菌得到充分的保障。
腔镜器械的清洗消毒流程:手术后的预处理、回收、分类、初步清洗、超声、刷洗、终末冲洗、消毒、防锈保养、干燥。
1、手术后的预处理,不可忽视。
国外有文献报道过,对于血迹变干的器械常规的清洗方法是无效的。
因此,手术后,手术室的护士负责及时拆卸器械,防止大块血渍阻塞腔镜管腔,并及时冲洗操作后器械附有大量的血液、粘液、分泌物等,并做好器械的保湿。
防止有机污染物凝固,造成清洗困难;减少污染物对器械的伤害,保护器械,降低感染风险。
2、由供应室工作人员专人回收。
回收过程应分类放置,轻抬轻放,防止撞击。
贵重(如镜头)和精密器械,必须双方签字交接。
3、器械的分类。
腔镜器械分类的同时要做好清点记录和认真检查器械的灵活性,完整性,检查器械是否变形,缺损,不能正常使用的要及时处理更换。
4、腔镜器械的清洗。
本文主要是针对不怕水的腔镜器械的清洗消毒操作流程。
内镜洗消标准和流程

•内镜洗消概述•内镜洗消标准•内镜洗消流程•内镜洗消操作注意事项•内镜洗消效果监测与评估目•内镜洗消相关法规与规范解读录01腹腔镜用于观察腹腔内脏器和组织病变,可进行手术操作。
内镜种类与特点电子胃镜具有高清晰度、高分辨率特点,可观察消化道黏膜病变。
肠镜用于观察大肠黏膜病变,可进行组织活检和息肉切除。
胸腔镜用于观察胸腔内脏器和组织病变,可进行组织活检和手术操作。
关节镜用于观察关节内部病变,可进行组织活检和手术操作。
内镜洗消的重要性和目的030201内镜洗消的历史与发展01清洗标准消毒标准消毒后的器械应无菌,不得检出任何微生物。
消毒后的器械应防再污染,使用时保持清洁状态。
手术器械应使用高效、广谱、稳定性好的消毒剂进行浸泡消毒。
终末漂洗标准终末漂洗使用软水或纯净水。
漂洗过程中应使用软毛刷彻底刷洗器械表面及轴节处。
漂洗后的器械表面应无残留物、无血渍、无锈渍。
干燥标准器械应使用干燥设备进行烘干,或使用清洁的棉布擦拭干净。
器械表面应干燥、无水渍、无锈渍。
器械的轴节部及弯曲部应彻底干燥,防止生锈。
01接收内镜检查内镜初步冲洗浸泡消毒预处理流程手工清洗流程刷洗内镜对内镜的配件进行清洗,确保无残留的污物和细菌。
清洗配件终末漂洗消毒使用消毒液对内镜及配件进行消毒处理,杀灭细菌和病毒。
清洗将内镜及配件放入自动清洗消毒机中,按照设定的程序进行清洗、消毒、干燥等处理。
干燥使用干燥设备对内镜及配件进行干燥处理,去除残留的水分和细菌。
自动清洗消毒流程终末漂洗干燥终末漂洗及干燥流程01操作前的准备事项检查内镜的完整性准备清洗设备和工具确认内镜的类型和材质03严格遵守消毒流程操作中的注意事项01正确使用清洗剂和消毒剂02彻底清洗内镜操作后的处理事项01监测方法监测频次监测方法与频次效果评估标准与流程不合格处理如内镜洗消效果监测不合格,立即停止使用该内镜,并按照医院规定进行整改和重新监测,直至合格为止。
改进措施针对监测中发现的问题,采取相应的改进措施,如提高清洗剂浓度、更换清洗设备、加强人员培训等,以提升内镜洗消效果。
腹腔镜手术器械使用清洗消毒和管理

(2)摄像头、冷光源电源线需用柔 软、吸水的布擦干,电源线不可折 叠,应无角度盘旋,放在抽屉内。
(3)各种器械使用及清洁时,应轻 拿、轻放,不得投掷或互相碰撞, 不可一手拿多样器械,以免滑掉损 坏。
(4)腹腔镜仪器、器械精密,昂贵。 因此,需有固定的位置放置,熟悉 仪器构造、工作原理及器械性能, 能熟练安装连接各种仪器,熟练掌 握器械技术性能用途,了解正确的 消毒方法,以及使用保养过程中的 注意事项,由受过专门培训的护理 人员来管理,并制定严格的保养及 管理制度。
必须要交班的内容:腹腔镜的镜头,确
认是零件完好,清晰,包装盒完好。 器 械数量正确,关节活动正常,无缺损。 如有损坏马上与腔镜组的同志联系,可 以更换或修理要交班。超声刀,结扎速, PK刀等属于易损物品,在交班时一定要 亲自与供应室的同志一起打开检查清楚。 预防过后产生不必要的纷争。
2.正确的清洗方法
(3)熟练管理仪器的性能和操作规 程,是手术成功的关键。
(4)腹腔镜手术要固定手术间进行, 以免搬动过多,否则容易造成仪器 零件松动脱落,并要配有稳压装置, 避免干扰和影响图像清晰。
(5)所有仪器、器械取放和清洁均 应动轻稳。仪器使用后注意检查 各零部件是否完整,有无缺损,并 关闭开关。
3.腹腔镜器械的消毒灭菌
我们使用的是等离子低温灭菌机,卡式高压锅对腔 镜器械进行灭菌处理。根据腹腔镜器械的材料而决 定其消毒灭菌的方法,使用前将器械放在灭菌器内, 用专用的灭菌剂按灭菌操作程序进行灭菌,等离子 低温灭菌机灭菌整个过程只需60-70分钟不等,卡 式高压锅具有快速、灭菌彻底等优点。整个过程仅 需9分钟。它们各有优点。这些灭菌器每灭菌1次, 都有灭菌指标记录和化学指示卡进行监测,我们根 据所显示的记录数据和化学指示卡变色的程度判断 灭菌效果,每天做1次生物监测,每台器械灭菌完 毕将灭菌指标数据和化学指示卡保留存档并登记。
腹腔镜手术器械清洗消毒标准流程

腹腔镜手术器械清洗消毒标准流程英文回答:Cleaning and disinfection of laparoscopic surgical instruments is a critical process to ensure patient safety and prevent the transmission of infections. Here is the standard procedure for cleaning and disinfection of laparoscopic surgical instruments:1. Pre-cleaning: As soon as the surgery is completed, the instruments should be pre-cleaned to remove gross debris and organic material. This can be done by rinsing the instruments with warm water or by using a soft brush to scrub off any visible residue. It is important to wear appropriate personal protective equipment (PPE) such as gloves and goggles during this process.2. Manual cleaning: After pre-cleaning, the instruments should be manually cleaned using a detergent solution or enzymatic cleaner. The instruments should be immersed inthe solution and scrubbed gently with a soft brush to remove any remaining organic material. Pay attention to the hinges, joints, and crevices where debris may accumulate. Rinse the instruments thoroughly with water to remove any detergent residue.3. Ultrasonic cleaning: After manual cleaning, the instruments should undergo ultrasonic cleaning. The instruments are placed in an ultrasonic cleaner filled with a cleaning solution. The ultrasonic waves create high-frequency vibrations that help to dislodge any remaining debris from the instruments. This process should be carried out for a specific duration as recommended by the manufacturer.4. Inspection: After ultrasonic cleaning, the instruments should be visually inspected for any signs of damage or residual debris. Any damaged or malfunctioning instruments should be removed from circulation and sent for repair or replacement. It is important to ensure that all instruments are thoroughly cleaned and free from anyvisible debris before proceeding to the next step.5. Drying: Once the instruments have been inspected, they should be dried thoroughly to prevent the growth of microorganisms. This can be done by air-drying or by using a clean, lint-free cloth. It is important to ensure that the instruments are completely dry before proceeding to the next step.6. Packaging: After drying, the instruments should be properly packaged to maintain their sterility. This can be done by placing the instruments in sterilization pouches or wrapping them in sterile packaging material. The packaging should be sealed securely to prevent contamination.7. Sterilization: The packaged instruments should undergo sterilization using an appropriate method such as steam sterilization or ethylene oxide sterilization. The sterilization process should be carried out according to the manufacturer's instructions and guidelines.8. Storage: Once the instruments have been sterilized, they should be stored in a clean and dry environment.Proper storage helps to maintain the sterility of the instruments until they are ready to be used in the next surgery.中文回答:腹腔镜手术器械的清洗和消毒是确保患者安全和预防感染传播的关键过程。
内镜清洗消毒手工操作流程图

内镜清洗消毒手工操作流程图一、床侧清洗内镜使用后湿酶纱布擦去外表面污物送气、送水至少10分钟取下内镜并装好防水盖置合适容器中送清洗消毒室二、侧漏取下各类按钮与阀门连接测漏仪将内镜完全侵入水中确认充气后弯曲部膨胀如有起泡逸出,请立即将内镜拿出及时送检条件不允许,应每日诊疗结束后对当日使用内镜侧漏1次三、清洗内镜放入清洗液槽内软布彻底冲洗镜身、操作部取下活检入口阀门、吸引器按钮、送气送水按按钮清洁毛刷彻底刷洗活检孔道刷洗时必须两头见刷头洗净刷头上的污物安装全管道灌流器吸清水注入送气送水管道反复冲洗、充气擦干内镜,清洗刷高水平消毒四、漂洗清洗后的内镜移入漂洗槽内用动力泵或压力水枪彻底冲洗各管道流动水冲洗内镜的外表面、按钮、阀门安装全管道灌流器擦干镜身、按钮、阀门五、消毒将内镜置于万金(戊二醛)消毒柜槽内浸泡各孔道用注射器灌满消毒液万金(戊二醛)消毒原液浸泡时间为15分钟结核杆菌、其他分支杆菌等特殊感染者,浸泡不少于40分钟需要灭菌的胃肠浸泡10小时当日不在继续使用的胃肠镜,无需延长时间六、终洗更换手套向管腔注入空气排尽消毒液内镜连同全管道灌流器置入终洗槽清洗内镜外表面彻底冲洗内镜各管道取下清洗时的各种专用管道和按钮七、干燥内镜置于专用干燥台用乙醇灌注各管道使用压力枪充气至少30秒至完全干燥纱布擦干内镜外表面安装按钮、阀门内镜感染管理制度1、建立并落实医院感染预防与控制的相关规章制度、工作规范及流程。
2、开展内镜诊疗工作的科室应当制定和完善内镜管理的各项规章制度及清洗、消毒或灭菌操作流程,并认真落实。
3、从事内镜诊疗和内镜清洗消毒工作的医务人员,应当具备内镜清洗消毒方面的知识,接受相关的医院感染管理知识培训,严格执行《内镜清洗技术操作规范(2004年版)》及相关规章制度。
4、不同部位内镜的诊疗工作分室进行;不能分室进行的,应当分时段进行,不同部位内镜的清洗消毒工作的设备分开。
5、内镜中心应配备与医院规模相适应的内镜及清洗消毒设备。
腔镜器械的清洗与保养

腔镜器械的清洗与保养在手术过程中会用到各种各样的腔镜器械,手术结束后,消毒供应中心工作人员会对这些腔镜器械进行统一回收,按照相关标准,实施清洗、灭菌、保养,通过这种方式,把腔镜器械上90%以上的病原体清除干净,有效预防感染,把各类传染疾病的传播风险降到最低。
一直以来,腔镜器械的清洗和保养都备受医院重视。
本文从3个方面详细介绍腔镜器械的清洗与保养,供大家了解,提高患者及家属对医院整体工作的信任!腔镜器械的清洗方法首先,腔镜器械的清洗与保养有严格要求,需要执行卫生部消毒、灭菌技术规范。
完成腔镜器械回收工作之后,使用含溶酶的清洗剂对腔镜器械中的手柄、套管等附件及腔镜本身进行浸泡,以2-3min为宜。
溶酶剂的作用在于对脂肪、蛋白质、管道内的凝集块、附件中的有机磷片进行消除、溶解,以此达到清洗目的。
其次,完成浸泡之后,使用清水对腔镜器械进行冲洗,其中,重点使用高压冲洗枪对管腔进行反复冲洗,并使用软毛刷把钳端齿槽内的污渍和血迹刷洗干净,继而擦拭,并吹干管腔内的水,随后涂抹润滑剂。
除了这种清洗方式外,还可以使用超声清洗器进行清洗。
在腔镜器械清洗过程中需要注意以下要点:1.针对Hbsag阳性及其他感染患者所使用的器械,一定要在清洗之前先进行消毒,以此遏制感染。
2.在钳子、剪刀清洗过程中,重点清洗关节重叠面的血迹,一定要保证清洗干净。
3.在腔镜器械清洗过程中,注意零碎部件保管,以防遗失。
4.严禁因失误把导线浸入清洗液内,规避漏电事故。
5.在腔镜器械清洗过程中,要注意对内镜镜面进行保护,不同镜面选择不同的擦拭工具。
纤维内镜、电子镜镜面分别使用棉球、纱布擦拭。
6.完成双极电凝钳的拆洗清洗工作之后,立即组装好,以免钳芯断裂。
同时,在清洗过程中还要加强注意,不能碰撞到宫腔镜电切器械操作梢套管的陶瓷口,谨防撞裂。
腔镜器械的灭菌处理腔镜器械种类不同,灭菌方式各异。
具体灭菌方式需要视腔镜器械及部件性能而定。
下面介绍几种常用的灭菌方式:1.高压蒸汽灭菌:这种灭菌方式应用范围非常广,适用于绝大多数腔镜器械。
腹腔镜手术器械清洗消毒标准流程

腹腔镜手术器械清洗消毒标准流程英文回答:Standard Process for Cleaning and Disinfection of Laparoscopic Surgical Instruments.Laparoscopic surgical instruments are an essential part of minimally invasive surgeries. Proper cleaning and disinfection of these instruments are crucial to ensure patient safety and prevent the transmission of infections. The following is a standard process for cleaning and disinfection of laparoscopic surgical instruments:1. Pre-cleaning:Immediately after use, remove visible debris, blood, and tissue from the instruments using a soft brush and running water.Avoid using abrasive materials or harsh chemicalsthat can damage the instruments.Rinse the instruments thoroughly to remove any remaining debris.2. Manual cleaning:Submerge the instruments in an enzymatic detergent solution, following the manufacturer's instructions.Use a soft brush or sponge to clean all surfaces of the instruments, paying special attention to hinges, joints, and crevices.Rinse the instruments thoroughly with clean water to remove any detergent residue.3. Ultrasonic cleaning:Place the instruments in an ultrasonic cleaning bath filled with an enzymatic detergent solution.Operate the ultrasonic cleaner according to the manufacturer's instructions, ensuring that all surfaces of the instruments are adequately exposed to the ultrasonic waves.Rinse the instruments thoroughly with clean water to remove any detergent residue.4. Inspection:Visually inspect the instruments for any signs of damage, such as corrosion, pitting, or loose parts.Ensure that all hinges, joints, and movable parts are functioning properly.Any damaged or malfunctioning instruments should be removed from service and sent for repair or replacement.5. Drying:Thoroughly dry the instruments using a lint-freecloth or air-drying cabinet.Ensure that all moisture is removed to prevent the growth of microorganisms.6. Packaging and sterilization:Place the dried instruments in sterilization pouches or containers suitable for the sterilization method to be used.Follow the sterilization guidelines and protocols recommended by the manufacturer.7. Storage:Store the sterilized instruments in a clean and dry environment, protected from dust and contamination.Regularly check the instruments for any signs of damage or deterioration during storage.中文回答:腹腔镜手术器械清洗消毒标准流程。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
腔镜清洗消毒流程
总体流程:
核对-清点—拆卸-预洗—酶洗—超声震荡-漂洗—润滑—干燥-灭菌-保存
具体操作:
核对:与交接单核对腔镜是否正确
|
清点:腔镜名称、件数
|
拆卸:拆卸腔镜到最小单位并检查其功能完好性
|
预洗:(1)腔镜器械边清点检查并拆至最小单位,流动水下用棉球擦洗表面;(2)连接全灌洗管道
按下计时器;(3)用喷枪冲洗管道,用清洗毛刷
刷洗管腔和配件;(4)清洗干净后,用气枪吹干.
|
酶洗:酶的作用为加速污物的分离和溶解,用时选择低泡酶。
(1)溶液按1:250配制,温度保持在
40℃~50℃;(2)接全灌洗管道,在酶中浸泡
10~15min。
注意酶每4h更换1次.
|
超声震荡:超声工作原理是通过换能器将高频电能转
换成机械能产生振幅极小的高频震动,并传播到
清洗槽内溶液中,在换能器的作用下,清洗液内
部不断地产生大量微小的气泡,并瞬间破裂,每
个气泡的破裂都会产生数百度的高温和近千个大
气压的冲击波,从而将清洗槽中的器械冲刷洁净,只要能接触到液体的地方就能达到清洗,使手工
洗不到的死角得以清洗。
配制溶液同酶洗中相同,将腔镜器械放在超声仪中震荡10min。
注意硬镜
和软镜不能震荡,螺丝容易振松动,要及时拧紧。
|
漂洗:用纯净水冲洗器械,同样接上全灌流管道漂洗10min。
|
润滑:附件及关节部浸入润滑油内30s,用3m外科器械润滑油,按1:10的比例配制浸泡30s后,
用气枪冲干。
|
干燥:用气枪及全灌洗冲干气冲干管腔及表面.
|
灭菌:1。
高压蒸汽灭菌法根据《内镜清洗消毒技术操作规范》2004版要求适应压力蒸汽灭菌的内
镜及附件应采用压力蒸汽灭菌,它具有许多优
点,但同时也存在许多的缺点,如对器械损害比
较大,缩短器械使用寿命,如硬镜高压消毒则要
求134℃ 5min,经高压消毒后的镜头不能立即
使用需放置6~12h才清晰。
2。
EO是目前最主要的低温消毒法,EO穿透力
强,灭菌效果确切,对腔镜器械损伤小.
3.等离子消毒是一种新的低温灭菌技术,具有
低温、干燥、快速、无毒等优越性,灭菌后器
械可以立即使用,使腔镜快速重复使用。
|
保存:灭菌后的腔镜及附件按无菌物品储存要求进行储存.。