PVCAD用户手册说明书
首次使用指南 迪士华器说明书

6. Clean the filter. 7. Re-insert the filter in the supply hose. 8. Screw the water connection back on. 9. Check the water connection for leaks. 10.Restore the power supply. 11.Switch the appliance on.
4. Place the lid back on the dispenser and turn to close.
2. Add rinse aid up to the max mark.
max
Programmes
The programme data has been measured in the laboratory according to European standard EN 60436. The consumption figures depend on the programme and additional function selected. The running time will change if the rinse aid system is switched off or rinse aid needs to be added.
2. Close the lid of the deter-
25 ml
gent dispenser.
15 ml
a The lid clicks into position.
9001811186 (030421) SMS6HVI01I
*9001811186*
How to use your aБайду номын сангаасpliance
pvc卡打印机使用说明书(精选5篇)

pvc卡打印机使用说明书(精选5篇)第一篇:pvc卡打印机使用说明书Pvc卡打印机使用说明书JF8600是一款热转印PVC卡打印机,同时也属于4色印刷的pvc 卡打印机,下面的就有小编给大家介绍一下JF8600这款产品的使用说明及在使用过程中的一些问题。
更换色彩/热印膜 1.打开打印机门2.按住盒子按钮,拉出盒子(右:色带盒,左:转印膜盒),去除色带/转印膜3.安装新的色彩/转印膜(1)安装是参照盒子上的粘胶标签(2)把带墨的/转印表面朝外,沿三个轴展开色带/转印膜,并稳稳插入筒管架4.拉进色带,沿导轨插入色带/转印膜.知道听到“咔哒”医生5.关上打印机门,按[RESET]重置打印机注意事项:1.如果打印功能已打开,打印机会被锁住。
从电脑关闭安全功能。
打印后,再从电脑打开安全功能。
2.更换色带/转印膜时,用双手握住盒子3.安装用过的色带时,把色带没有用过的黄色面与盒子标签上所示箭头对齐4.按图所示,把盒子竖放在平整的表面上5.拉紧色带/转印膜否则可因表面褶皱而导致堵塞或者造成色彩不均6.不要用手接触带墨的转印表面(安装时朝外的那一面),处理色带/转印膜时戴上手套7.不要再打印机门上操作,不要再打印机上放置重物或者施加负荷8.安装新的转印膜时,确定至少三条黑线卷到了卷轴上打印卡片 1.打开电源2.检查确保卡片插入送卡箱3.打开打印设置屏幕,在[Printers]中选择本打印机4.确保打印机的液晶控制面板上出现[Ready]字样后,开始打印注意事项1.如果您在打印的液晶控制面板上看到[Initializing...]或者[Preheating...]字样,这表示打印机尚未做好准备。
在打印机做好准备前,无法进行打印。
2.在卡片带磁条的一面上打印,可能会造成打印错误,或损坏卡片功能。
如果您要这么做,请事先跟商家进行沟通补充卡片 1.把送卡箱的旋钮设置在open上2.上提,取下送卡箱外盖3.对齐卡片方向,把卡片放进打印机4.装上送卡箱外盖注意事项1.如果安全功能已打开,送卡箱会被锁住,从电脑关闭安全功能。
CPVC管材使用指南说明书

Don’t s____________________________♦Do not use edible oils such as Crisco as a gasket lubricant.♦Do not use petroleum or solvent-based sealants, lubricants, or fi re stop materials.♦Do not install tape, insulated wire or cable in direct contact with CPVC.♦Do not use any glycol-based solutions as an anti-freeze.♦Do not mix glycerin and water solutions in contaminated containers.♦Do not use solvent cement that exceeds its shelf life or has become discolored or jellied.♦Do not allow solvent cement to plug the sprinkler head orifi ce.♦Do not connect rigid metal couplers to CPVC grooved adapters.♦Do not thread, groove, or drill CPVC pipe.♦Do not use solvent cement near sources of heat, open fl ame, or when smoking.♦Do not pressure test with air.♦Do not pressure test until recommended cure times are met.♦Do not use ratchet cutters below 50°F.♦Do not use CPVC pipe that has been stored outdoors, unprotected and is faded in color.♦Do not allow threaded rod to come in contact with the pipe.♦Do not install Spears® FlameGuard® CPVC Fire Sprinkler Products in cold weather without allowing for expansion.♦Do not install Spears® FlameGuard® CPVC Fire Sprinkler Products in dry systems.Note: This list does not constitute a complete installation guide.Do s______________________________♦Read the manufacturer’s installation instructions.♦Follow recommended safe work practices.♦Make certain that thread sealants, gasket lubricants, or fi restop materials are compatible with CPVC.♦Keep pipe and fi ttings in original packaging until needed.♦Cover pipe and fi ttings with an opaque tarp if storedoutdoors.♦Follow proper handling procedures.♦Use tools specifi cally designed for use with plastic pipe andfi ttings.♦Use the proper solvent cement and follow applicationinstructions.♦Use a drop cloth to protect interior fi nishes.♦Cut the pipe ends square.♦Deburr and bevel the pipe end with a chamfering tool.♦Rotate the pipe ¼ turn when bottoming pipe in fi tting socket.♦Avoid puddling of cement in fi ttings and pipe.♦Make certain no solvent cement is on sprinkler head andadapter threads.♦Make certain that solvent cement does not run and plug thesprinkler head orifi ce.♦Follow the manufacturer’s recommended cure times prior topressure testing.♦Flush the entire system including drops to remove pipeshavings, dirt and debris left from installation.♦Fill lines slowly and bleed the air from the system prior topressure testing.♦Support sprinkler head properly to prevent lift up of the headthrough the ceiling when activated.♦Keep threaded rod within 1/16" of the pipe or use a surgearrestor.♦ Install Spears® FlameGuard® CPVC Fire Sprinkler Productsin wet systems only.♦Use only glycerin and water solutions for freeze protection.♦Allow for movement due to expansion and contraction.♦Renew your Spears® FlameGuard® CPVC Fire SprinklerProducts installation training every two years.Recommended Practicesand PrecautionsDo s and Don’t sPACIFIC SOUTHWEST15860 Olden St.Sylmar (Los Angeles), CA 91342(818) 364-1611 • (800) 862-1499Fax (818) 367-3014ROCKY MOUNTAIN4880 Florence St.Denver, CO 80238(303) 371-9430 • (800) 777-4154Fax (303) 375-9546NORTHEAST590 Industrial Dr., Suite 100Lewisberry (Harrisburg), PA 17339-9532(717) 938-8844 • (800) 233-0275Fax (717) 938-6547MIDWEST1 Gateway Ct., Suite ABolingbrook (Chicago), IL 60440(630) 759-7529 • (800) 662-6330Fax (630) 759-7515NORTHWEST4103 C St., NE Suite 200Auburn (Seattle), WA 98002(253) 939-4433 • (800) 347-7327Fax (253) 939-7557UTAH5395 West 1520 SouthSalt Lake City, UT 84104(303) 371-9430 • (800) 777-4154Fax (303) 375-9546SOUTH CENTRAL1000 Lakeside ParkwayFlower Mound, TX 75028(469) 528-3000 • (800) 441-1437Fax (469) 528-3001FLORIDA9563 Parksouth CourtOrlando, FL 32837(407) 843-1960 • (800) 327-6390Fax (407) 425-3563SOUTHEAST4205 Newpoint Pl., Suite 100Lawrenceville (Atlanta), GA 30043(678) 985-1263 • (800) 662-6326Fax (678) 985-5642INTERNATIONAL SALES15853 Olden St.Sylmar (Los Angeles), CA 91342(818) 364-1611 • Fax (818) 898-3774SPEARS® MANUFACTURING COMPANYCORPORATE OFFICE15853 Olden St., Sylmar, CA 91342PO Box 9203, Sylmar, CA 91392(818) 364-1611 • © Copyright 2007 Spears® Manufacturing Company. All Rights Reserved.Printed in the United States of America 06/07. FG-3A-0607Certifi cation BoardInternational LaboratoriesAmerican Society forTesting and MaterialsResearch CorporationRecommended Cut-in Procedures for SystemModifi cation or RepairExisting system modifications or repairs can be made using Spears® FlameGuard® CPVC Fire Sprinkler Products. In order to maintain full system integrity, the following procedure must be followed when making a system tie-in or repair by cutting into an existing system line. A careful review of all Joining Procedures must be made prior to making a cut-in on an existing system and the Minimum Cut-in Cure Times listed below must be followed. A variety of fi tting combinations can be used to tie into an existing system or replace a section between fixed cut-in points. These include using a socket Tee for add-ons or a socket Coupling for repairs in combination with a mechanical joint such as a union grooved coupling adapter, or flange. Regardless of the components selected, the following must be adhered to:1 System modification cut-ins should be made on the smallest diameter pipe section, in close proximity to the area of modifi cation, capable of properly supplying the system change.2 Carefully plan and measure prior to cutting into existing system. Be sure to provide adequate space and insure that full insertion into fi tting sockets can be made during assembly. Note: Allowance must be made for making a 1/4-turn twist when inserting the pipe into the fitting during assembly of the tee (or other component), especially on 1-1/2" and larger pipe sizes. This may require assembly of components in combination with the cut-in tee to create a short spool piece for fi nal connection using socket unions, fl anges, or grooved coupling adapters.3 Review all Installation & Joining procedures prior to commencing cut-in (including square cutting, deburring & beveling, cleaning, dry fi t checks).4 Depressurize and drain existing line prior to making the cut-in.5 Connect to the existing system prior to proceeding with the modifi cation or repair.6 All pipe shavings, dirt, debris must be removed fromthe cut-in system and, water and residual moisture must beremoved from all solvent cement areas. Vacuum lines and wipedry with a clean dry rag. Moisture and dirt will slow the curing andcan affect joint strength.7 Use only a new can of approved solvent cementwhen making cut-in connections. Verify cement expiration dateon can prior to use.8 The cut-in joint must be allowed to cure prior topressure testing as shown in the table at the right.9 Following completion and proper cure, inspectfor proper alignment and hanger placement prior to pressuretesting.10 To pressure test the system, slowly fill the systemwith water and make sure that all air is bled from the farthest andhighest point before test pressure is applied. The system MUSTbe pressure tested in accordance with NFPA 13, NFPA 24, or anyother applicable NFPA standard requirement. The system mustbe tested with water. The purpose of the hydrostatic pressuretest is to check for leakage, and it may not identify improperlyassembled joints. This test MUST NOT be considered a substitutefor full compliance to these published installation instructions.It is recommended that the portion of the sprinkler systemcontaining the cut-in tee be isolated for pressure test wherepossible. The applied test pressure should not exceed 50 psiover the system pressure in order to minimize water damage inthe event that a leak occurs.WARNING: Spears® FlameGuard® CPVC Fire Sprinkler Productsmust never be used or tested in a system of compressed air orother gases. Air must be removed from piping systems. Entrappedair can generate excessive surge pressures, regardless of thepiping materials used. Failure to follow this warning could resultin product failure, property damage and severe personal injuryor death.Note 1: Solvent cement can be applied at temperatures below 40°F (4°C) in all sizes. For the 2-1/2" & larger, the temperaturemust be raised to 40°F (4°C) or above and allowed to cure for the recommended times before the system is fi lled and pressurized.Cement, pipe or fi ttings brought in from colder outside temperatures must be brought up to room temperature before using the 60°Fto 120°F cure schedule.Cut-ins for modifi cations or system repairs are often made under less than ideal situations as compared to new installations. As aresult, the following specifi ed Minimum Cut-in Cure times must be used.。
DYMO D1 耐用乳胶(PVC)带说明书

DYMO D1 Durable Vinyl (PVC) TapeDescriptionDYMO D1 Durable Vinyl tape is formulated with a permanent acrylic adhesive and atopcoat specifically for thermal transfer printing. Dymo D1 Durable labels are perfect forlabeling kitchens, pantries, utility closets, laundry rooms, garages, workshops, sportsequipment, outdoor storage, and more.This tape is recommended for indoor andoutdoor use and can be used on flat and curved surfaces.DYMO Part NumbersAvailable Colors & SizesCertifications and & Standards Adherence-To the best of our company’s knowledge we d eclare that our products meet the most recentstandards of the European Directives considering REACH and ROHS. None of the substancesidentif ied as “substance of concern“ has been and will be contained in the product(s), listed onthis Technical Data Sheet, to a higher level than mentioned in the European Directivesconsidering REACH and ROHS.Physical Properties-Total Thickness: 178 µm +/- 10%-Dimensional Stability (%):▪Machine Direction <1.0 observed on an aluminum panel at 70°C (158°F)for 24 hrs.▪Transmission Direction <1.0 observed on an aluminum panel at 70°C(158°F) for 24 hrs.Adhesive Properties (tested per FTM 1 – Modified for 72 hr dwell time)Adhesion to Surfaces-Tack (ASTM D 2979):800gm/cm²Temperature RatingsChemical ResistanceTest Method: Crockmeter, 900g weight/arm1. Printed with black ribbon:2. Printed with white ribbon:UV Light ResistanceHumidity Resistance-Printed labels adhered to aluminum surface for 30 days at 45°C (113°F), 85% Relative Humiditywith no visible effect on text or background; Slight shrinkage of materialShelf life of label cassette-Two years stored at 21°C (69.8°F) and 50% Relative HumidityNotice-This product is not developed to be used on humans, animals and/or in direct foodcontact. It is not recommended to be used in dish-washers.All of the descriptive information, performance data, and recommendations for the use of DYMO products shall be used only as a guide and do not reflect the specification or specification range for any particular property of the product. Furnishing such information is an attempt to assist you and in no event will constitute a warranty of any kind by DYMO or DYMO distributors. All purchasers of DYMO products shall be responsible for independently determining the suitability of the material for the purposefor which it is purchased.。
TIGRE PVC 型号 02 产品 使用指南说明书

DRENAJEVENTAJASInnumerables son las ventajas para quien utiliza tubos y conexiones para drenaje de la marca TIGRE; estas son las más significativas:Mejor desempeño hidráulico. Por sus paredes internas lisas y por su mayor área de perforación por metro, los drena-jes corrugados y perforados TIGRE presentan mayor desem-peño hidráulico.Ligereza. Peso reducido en comparación a los materiales tradicionales.Economía. Debido a su flexibilidad, reducido peso y pérdi-das por quiebra prácticamente nulas, se torna un producto económico y de fácil transporte.Mayor vida útil. Posee aberturas adecuadamente dimen-sionadas, los drenajes de PVC TIGRE impiden la penetración y depósito del material filtrante, asegurando una mayor vida útil para el sistema.Facilidad en la instalación. Los tipos de unión, tanto soldable, elástica o simples encajes, le dan gran velocidad a la instalación, por la facilidad del montaje.Gran flexibilidad. Las propiedades de los materiales plásti-cos, aseguran la continuidad de la línea drenaje en los casos de deformaciones del suelo.Elevada resistencia a la compresión diametral. Las corrugaciones a lo largo del tubo aumentan su resisten-cia a la compresión diametral, dando mayor garantía a las cargas externas.Elevada resistencia química. No sufren la acción química del suelo, los tubos TIGRE para drenaje, garantizan una mayor vida útil a la red de drenaje.Largos. Fabricados en tiras de 6 metros para el tubo rígido, y rollos de 100 y 50 metros los tubos reducen mucho la mano de obra de la instalación.Conexiones. En el caso de los tubos flexibles se puede disponer de todas las conexiones del sistema Ramat domici-liario, siendo su unión perfecta.RECOMENDACIONES PARA INSTALACIÓNTIGRE ofrece a los ingenieros y técnicos esta nueva opción para drenaje subterráneo, presentando una línea de productos, introduciendo nuevos conceptos en las tradicionales técnicas hasta entonces utilizadas.No sólo la calidad de los drenajes de PVC TIGRE contribu-ye decisivamente para la preferencia de los proyectistas e instaladores, sino también las ventajas inherentes de estos productos, entre las cuales citamos: liviandad, elevada resistencia diametral, mayor área de perforación por metro y gran facilidad en la instalación, representando una mayor vida útil para el sistema de drenaje.Más adelante presentamos algunas orientaciones sobre la instalación de estos productos y recomendamos sean estudiados, con la finalidad de proporcionar el mayor desempeño y aprovechamiento de las ventajas que los mismos pueden ofrecer.02Para unir los tubos entre sí, usar la unión sencilla de 100 mm. Para desagües, con adhesivo Tigre para PVC. No utilizar anillo de goma.INSTALACIÓNCARACTERISTICAS DEL ACOPLAMIENTOLas piezas del acoplamiento del sistema DRENOFLEX, básicamente cuplas y adaptadores, presentan un sistema exclusivo de garras (desenvolvimiento TIGRE) que permi-ten introducir fácilmente el tubo y poseen una resistencia elevada al desmontaje (buena traba). La instalación puede proseguir con facilidad y sin peligro de desacoplamiento de las juntas que ya fueron montadas. A continuación se evidencia la facilidad del mecanismo de instalación.TUBO DRENOFLEXCONEXIÓN(LINEA RAMAT)ø 101,6DN 10003CARACTERÍSTICAS DIMENSIONALESCARACTERÍSTICAS DIMENSIONALES DE LOS TUBOSCARACTERÍSTICAS DIMENSIONALES DE LAS BOBINAS La planilla de abajo, son indicaciones con dimensiones aproximadas, cuyo objetivo es facilitar el planeamiento de transporte y el stock del material (volúmenes y pesos), también sirve como orientación para el desenvolvimiento de dispositivos de meca-nización de instalaciones, o para facilitar controles de stock y recibimiento de obra.0405APLICACIONESUtilizado en los más diversos tipos de drenaje, como ser edificaciones, carreteras, vías férreas, muros de contención, empasta-dos, campos deportivos, agricultura, y otros. Destacamos a continuación las más importantes, presentando nuestras recomen-daciones para que se obtenga un mejor desempeño de los mismos.Entre las aplicaciones en la Construcción Civil, destacamos el drenaje de muros de apoyo y el rebaje del nivelAPLICACIONES EN LA CONSTRUCCIÓN CIVILDrenaje en muros de apoyo• La calidad de los tubos de drenaje aplicados dependerá de la capacidad del filtro, extensión y altura del muro.• Normalmente, se hace más de una camada de tubos de drenaje para el escurrimiento del agua.• La aplicación de los tubos internos favorece la rapidez en el escurrimiento.• El filtro utilizado junto a la parte interna del muro deberá ser dimensionado para evitar la salida de partículas finas del material contenido.Rebaje del nivel freáticoLa protección de los predios contra las aguas de infiltración es otra de las aplicaciones usuales de los tubos de drenaje. Como en todas las aplicaciones, la distancia entre los drena-jes es en función de su profundidad y la capacidad del tubo es en función de la calidad del agua a drenar.Así, en esta aplicación, recomendamos mantener el declive constante y procurar no ahogar el drenaje.06APLICACIONES EN CAMINOS PAVIMENTADOSEs posible la utilización de la línea de drenaje para este fin pero es importante atender fin las especificaciones del proyectista. Las consideraciones generales se pueden apreciar en el gráfico.Fig. 3Fig. 4Para esas aplicaciones las formas de las líneas drenantes más empleadas son las espina de pez y paralelas.APLICACIÓN EN JARDINES Y CAMPOS DEPORTIVOSEn este caso, recomendamos:• Las distancias entre los drenajes, varían en función del suelo, pero como dato práctico, se puede adoptar la siguiente distancia:10 metros – para terrenos con más de 70 % de arcilla 15 metros – para terrenos con media mezcla (40% de arcilla).20 metros – para terrenos con un máximo de 20 % de arcilla.• P rocurar mantener la pendiente en todas las líneas, eliminando los posibles depósitos, debidos a la velocidad constante.• La profundidad deberá estar entre 0,8 a 1 metro.APLICACIONES EN LA INFILTRACIÓN DE DESAGÜES SANITARIOSLos tubos de drenaje presentan una práctica solución en la disposición de los afluentes de Cámaras Sépticas, (Fosas) ,a través del sistema de infiltración en el terreno.En esta aplicación, recomendamos observar los siguientes puntos:• Mantener una distancia mínima de 30 metros, entre las líneas de infiltración y la fuente de abastecimiento del agua.• El declive entre la cámara séptica y la caja de distribución debe ser mantenido en 2%, en cuanto que para la infiltración• La granulometría del cascajo para el lecho de la línea de riego deberá estar comprendida entre 1 a 6 cm.• Las dimensiones y el tipo de relleno de zanja deberán seguir el esquema de la Fig.7.• Todas las salidas de la caja de distribución deberán estar en el mismo nivel.•Fig. 6Fig. 70708APLICACIONES EN EL DRENAJE AGRÍCOLALa opción del tipo de drenaje: de descarga (paralelo o espina de pez) o interceptor; el cálculo del espacio entre los drenajes y su dimensionamiento y requieren estudiosDe una manera general, la profundidad de los drenajes para regiones áridas está entre 1,5 a 2 metros, en cuanto que para regiones húmedas, de 1 a 1,5 metros.ASENTAMIENTODeberán ser tomadas medidas de precaución para el asentamiento, previendo un material de buen soporte lateral para cuando el tubo estuviera sujeto a grandes cargas de compresión, a fin de evitar una deformación diametral, no compatible con el uso.En cuanto al filtro que envuelve los tubos, se debe prever su correcto dimensionamiento, para que con el correr del tiempo, tengamos siempre un buen sistema drenante.Para eso determinadas condiciones como uniformidad y permeabilidad del filtro deberán ser observadas.En la página siguiente presentamos una tabla con datos de los tubos TIGRE de PVC para drenaje, que auxiliarán los cálculos del sistema drenante.FIG. 909COLOCACIÓN PUNTERA HEMBRAEN TUBO RÍGIDOA – Material necesario: trapo, pincel, lija Nº100, solución limpiadora TIGRE y adhesivo TIGRE.B – Lijar internamente la bolsa deltubo, hasta sacar todo el brillo.C – Lijar externamente la punta del tubo, hasta sacar el brillo.D – Limpiar con el trapo humedecido con solución limpiadora TIGRE, lapuntera hembra y el tubo ya lijados.E – Medir la profundidad de la bolsa.F – Marcar en la punta del tubo laprofundidad de la bolsa.G – Utilizar el pincel para aplicar, sin exceso, el adhesivo TIGRE en la bolsa del tubo.H – Aplicar igualmente el adhesivo TIGRE, en la puntera.Si el tubo fuera Drenoflex se puede considerar la utilización de una cupla deslizante de 110 de la línea Ramat. En caso de lecho nitrificante consultar al departamento técnico.I – Introducir la punta del tubo en elfondo de la bolsa, observando laposición de la marca hechaanteriormente.J – La junta soldada está lista.REPARACIÓN DE PEQUEÑAS ROTURASA –Cuando hay pequeñas roturas enla red, utilizar una sierra para cortar eltrecho damnificado.B – Cortar una cupla doble en elsentido longitudinal.C – Lijar (lija nº100) externamente lasextremidades del tubo cortado einternamente la cupla.D – Con el trapo humedecido con lasolución limpiadora TIGRE, limpiar laspartes lijadas.E – Utilizando un pincel aplicaradhesivo TIGRE sobre las superficiesdel tubo anteriormente lijadas.F – Aplicar igualmente el adhesivoTIGRE, en la parte interna de la cupla.G – Ejerciendo presión manual, abrirla cupla para encajarla sobre el tubo.H – La ejecución de la reparaciónestá lista.1011ROTURAS MAYORES CATÁLOGO DE PIEZASY DIMENSIONESRoturas mayores Cuando existe una rotura mayor en el tubo, se corta, con ayuda de un sierra, el trecho damnificado, y de otro tubo se corta una parte con el mismo largo al de la parte retirada menos dos veces la anchura del anillo de la cupla.Se coloca este tubo en el espacio de la línea. Se suelda con adhesivo TIGRE una cupla en una de las extremidades de la tubería, con una de las extremidades del tubo intercalado.Para completar el reparo de la otra extremidad, se corta una cupla en el mismo sentido longitudinal y por medio del adhe-sivo se fija la misma sobre la enmienda existente, comple-tándose de esta manera el arreglo.Para la ejecución del pegado de las dos cuplas, sólo hay que seguir las especificaciones apuntadas para el reparo de la red anterior.Enmiendas de tubos cortados Cuando se hace necesario el acoplamiento o el aprovecha-miento de pedazos de tubos cortados, la unión de los mismos deberá ser hecha con la ayuda de la cupla, que es insertada sobre la corrugación helicoidal de los tubos. DrenoflexCotas (mm)L (mm)DE (mm)Ø 65Ø 110Código 008000815000500065.2110Di(mm)58101.40085Cotas (mm)L (mm)DE(mm)Ø 100Código 6000101.6Drenaje RígidoCotas (mm)A (mm)B (mm)Ø100X101.6Código 324114265C (mm)55D (mm)101.6DE (mm)101.6Reducción 110x100Cotas (mm)A (mm)D(mm)Ø 100Código 1339132110Puntera Hembra。
PVC型材操作规程

退刀应灵活
2、锯片不应有掉齿现象2、找一节型材进行切割看是否有大的破口
汽缸下
、
1、标准操作工
依据制造异常处理方法处理
2、自然光线下目测其外观
未设标准操作工艺卡者反映
1、用游标卡尺量取型材配合尺寸,几何尺寸
3、真空度不够
4、物料温度偏低
5、模头与定型模距离太远
6、真空度不够
7、一级定型套内有物料3、增加密封,提高真空度 ,调试真空泵
4、调整模头与挤出机温度(生温度)
5、减小模头与定型模之间的距离
6、条件允许时,可在收缩痕部位增加气孔
7、清理定型套
堵塞
3、牵引速度太慢(挤出和牵引不匹配)
4、型材局部出料不均匀
5、局部温度失控
6、机身模头温度不稳定,忽高忽低
7、定型模进料口导入斜度过小过短
8、定型模堵模处尺寸小2、检查,调整牵引机
3、提高牵引速度
4、调整间隙至均匀
5、检查加热板是否失控
6、检查温控系统,调整温度稳定
7、增大定型模进料口模斜度和长度
8、加大其尺寸
2、第一节定型模真空度太高或太稳定
3、定型模不在一条直线上,阻力过大
4、局部阻力过大
5、冷却不充分2、适当降低真空,检查真空泵
3、检查定型模是否在一条直线上
4、在许可时减少供料,修正定型模,增大间隙
5、降低水温,局部拐弯第一节加强冷却
2、牵引速度过快或过慢
3、型材两侧大面供料不够
4、冷却不充分
5、牵引机压力过大2、调节牵引速度使型材到达标准重量
3、加强两侧供料
4、降低冷却水温或加大冷却水量
5、适当降低牵引机压力。
PECVD操作手册中英文版【Word版】128p

Windows 2000 English with Service Pack 4 is used as operating system for controlling and operating PC.采用Windows 2000 English with Service Pack 4 操作系统。
Visual system with VAC_NT, Version 3.0 带VAC_NT的可视化系统, 3.0版本Graphic visualization of all data, set points, process states and user inputs 所有数据,设定点,过程状态和用户输入的图像可视化Menu-controlled process operating with keyboard and touch pad.带键盘和触摸板的菜单控制过程操作Manual operation for selected functions. 已选功能的人工操作Automatic operation for processes using parameters 使用参数过程的自动操作Database-oriented control and management of procedures 数据库导向控制和管理程序Event-controlled message logging 事件控制信息的录入Protocol recording during the process run 工艺运行过程的协议记录Diagnosis function (I/O list) 诊断功能(I/O 清单)1.3 Installation instruction for the main components 主要元件的安装指示For the installation of the SIMATIC peripheral components see the section in the System manual “Local peripheral equipment ET200M” (Order No.: 6ES7 153-1AA01-8AA0). SIMATIC外围元件的安装参见系统手册“Local peripheral equipment ET200M” (Order No.: 6ES7 153-1AA01-8AA0).For SINEC-L2 connection comply with the Technical Description and the Installation Guidelines in the Manual “CP5613”. SINEC-L2的连接遵守技术描述和和安装向导,在手册“CP5613”。
Spears PVC 排水管产品和配件说明书

PVC Schedule 80 FittingsPRODUCTContact Spears® for any Information not found.TeesPart Number Size StdPkMstrCtnProdCodeMSRPTeeSocket x Socket x Socket801-0021/45030008019.46 801-0033/82515008019.46 801-0051/22520008019.46 801-0073/41512008020.40 801-010*********.53 801-0121-1/410008070.16 801-0151-1/210008070.16 801-020*********.73 801-0252-1/210008095.36 801-030350080119.20 801-040450080138.11 801-050550080336.89 801-050F514083787.41 801-060620080471.56 801-0808200801093.69 801-080F8100831031.61 801-10010100813613.30 801-100F10100831833.30 801-12012100815102.99 801-120F12100832583.21 801-14014100826424.61 801-140F14100835419.46 801-160F16100837046.96 801-180F181********.51 801-200F201008310822.56 801-240F241008314383.50 Tee - ReducingSocket x Socket x Socket801-1013/4X1/21512008014.94 801-1301X1/215008021.56 801-1311X3/415008021.56 801-1571-1/4X1X3/415008035.61 801-1581-1/4X1X115008035.61 801-1591-1/4X1X1-1/415008035.61 801-16611-1/4X1/210008059.52 801-1671-1/4X3/410008046.83 801-1681-1/4X115008046.83 801-2021-1/2X1-1/4X110008046.83 801-2091-1/2X1/210008046.83 801-2101-1/2X3/415008046.83 801-2111-1/2X110008046.83 801-2121-1/2X1-1/410008046.83 801-2472X1/210008059.32 801-2482X3/410008059.32 801-2492X110008059.32Part Number SizePk Ctn CodeMSRP Tee - Reducing (continued)Socket x Socket x Socket801-2502X1-1/410008090.46 801-2512X1-1/210008059.32 801-25412X2X450080414.42 801-2872-1/2X1/210008090.69 801-2882-1/2X3/410008090.69 801-2892-1/2X110008077.40 801-2902-1/2X1-1/410008077.40 801-2912-1/2X1-1/210008077.40 801-2922-1/2X210008077.40 801-33313X1/250080108.77 801-3343X3/460080122.77 801-3353X150080108.77 801-33613X1-1/450080108.77 801-3373X1-1/250080108.77 801-3383X250080108.77 801-3393X2-1/260080108.77 801-41514X1/250080215.12 801-41614X3/450080215.12 801-4174X150080215.12 801-41814X1-1/450080215.12 801-4194X1-1/250080175.78 801-4204X250080175.78 801-42114X2-1/250080316.42 801-4224X350080175.78 801-42614X640080861.43 801-48215X1-1/440080696.93 801-482F5X1-1/415083465.98 801-48415X1-1/240080759.78 801-484F5X1-1/215083474.78 801-48615X240080661.09 801-486F5X215083474.78 801-48715X2-1/240080769.06 801-487F5X2-1/214083541.38 801-48815X340080661.09 801-488F5X314083559.09 801-49015X440080524.37 801-490F5X414083596.86 801-52316X1/240080457.14 801-52416X3/460080457.14 801-5256X160080351.22 801-525F16X140083406.29 801-52616X1-1/440080457.14 801-52716X1-1/240080457.14 801-527F6X1-1/214083474.78 801-5286X260080351.22 801-52916X2-1/240080456.74 801-5306X350080351.22 801-530F6X313083519.23 801-5326X450080471.56 801-533F6X513083992.62 801-537F6X10100833863.58 801-539F6X12100834289.86 801-57318X1/2200801342.00 801-57518X1200801342.80TeesPart Number Size StdPkMstrCtnProdCodeMSRPTee - Reducing (continued)Socket x Socket x Socket801-57818X2200801276.83 801-578F8X212083875.84 801-57918X2-1/2200801404.88 801-579F8X2-1/212083883.96 801-58018X3200801276.83 801-580F8X312083893.89 801-5828X4200801276.83 801-582F8X412083939.92 801-583F8X5100831270.67 801-5858X6200801093.69 801-59118X12100817802.17 801-621F10X2120831315.67 801-622F10X2-1/2100831374.14 801-623110X3100813366.52 801-623F10X3100831411.03 801-624110X4100813366.52 801-624F10X4100831461.81 801-625F10X5100831572.01 801-62610X6100813179.71 801-626F10X6100831653.21 801-628110X8100813742.09 801-628F10X8100831854.64 801-632F10X12100834568.57 801-661F12X2100831701.29 801-662F12X2-1/2100831774.71 801-663F12X3100831832.63 801-664112X4100816103.62 801-664F12X4100831944.08 801-665F12X5100832037.26 801-666112X6100815758.62 801-666F12X6100832146.64 801-66812X8100814730.49 801-668F12X8100832303.08 801-670112X10100816334.78 801-670F12X10100832559.19 801-678F12X181008311407.49 801-691F14X2100832131.71 801-692F14X2-1/2100832239.48 801-693F14X3100832617.16 801-694F14X4100832884.08 801-696F14X6100833113.37 801-698114X8100827328.99 801-698F14X8100833273.89 801-700114X10100825204.68 801-700F14X10100833497.60 801-70214X12100826058.66 801-702F14X12100833693.23 801-706F14X16100838885.56 801-751F16X2100832733.58 801-752F16X2-1/2100832907.52 801-753F16X3100832949.20Part Number SizePk Ctn CodeMSRP Tee - Reducing (continued)Socket x Socket x Socket801-620F10X1-1/2100833245.37 801-754F16X4100833226.49 801-756F16X6100833432.48 801-758F16X8100833812.51 801-760F16X10100834132.80 801-762F16X12100834554.43 801-764F16X14100835251.63 801-781F18X2100833142.42 801-783F18X3100833826.03 801-784F18X4100835875.80 801-786F18X6100836364.06 801-788F18X8100836636.57 801-790F18X10100837109.79 801-792F18X12100837513.62 801-794F18X14100837985.10 801-796F18X16100838087.12 801-814F20X4100837206.31 801-816F20X6100837609.11 801-818F20X8100837842.99 801-820F20X10100838167.11 801-822F20X12100838757.22 801-824F20X14100839390.93 801-826F20X161008310065.36 801-828F20X181008310579.51 801-904F24X4100838972.80 801-906F24X6100839316.46 801-908F24X8100839558.70 801-910F24X101008310146.97 801-912F24X121008310521.37 801-914F24X141008310955.53 801-916F24X161008311460.94 801-918F24X181008313862.66 801-920F24X201008314126.00 1 Sized with BushingTeeSocket x Socket x Fipt802-0021/42515008045.02 802-0051/22016008030.81 802-0073/42016008039.84 802-010*********.63 802-0121-1/415008049.82 802-0151-1/210008058.58 802-020*********.26 802-0252-1/250080143.58 802-030350080154.18 802-040450080289.67 802-060F620083596.53 802-080F8120841277.44TeesPart Number Size StdPkMstrCtnProdCodeMSRPTee - ReducingSocket x Socket x Fipt802-1013/4X1/21512008028.29 802-1301X1/250008029.40 802-1311X3/415008037.78 802-1661-1/4X1/225008048.07 802-16711-1/4X3/415008048.07 802-1681-1/4X110008095.42 802-20911-1/2X1/225008059.52 802-21011-1/2X3/420008059.52 802-2111-1/2X110008059.52 802-2121-1/2X1-1/410008059.52 802-2472X1/210008067.99 802-2482X3/410008067.99 802-2492X110008090.46 802-25012X1-1/410008090.46 802-25112X1-1/2100080126.14 802-2872-1/2X1/2100080156.54 802-28812-1/2X3/4100080156.54 802-28912-1/2X1100080156.54 802-29012-1/2X1-1/4100080156.54 802-29112-1/2X1-1/2100080156.54 802-29212-1/2X2100080174.78 802-33313X1/250080122.77 802-33413X3/450080122.77 802-33513X150080147.66 802-33613X1-1/450080147.66 802-33713X1-1/250080147.66 802-33813X250080188.54 802-33913X2-1/250080265.17 802-41514X1/250080216.03 802-41614X3/450080216.03 802-41714X150080216.03 802-41814X1-1/450080216.03 802-41914X1-1/250080216.03 802-42014X250080322.90 802-42114X2-1/250080322.90 802-42214X350080361.48 802-52516X140080502.66 802-52616X1-1/440080502.66 802-52716X1-1/240080502.66 802-52816X240080502.66 802-528F26X213083915.40 802-52916X2-1/240080502.66 802-53016X340080701.71 802-53216X420080735.21 802-532F26X4140831134.37 802-57818X2200801370.02 802-578F8X2120831225.94 802-58018X3200801370.02Part Number SizePk Ctn CodeMSRP Tee - Reducing (continued)Socket x Socket x Fipt802-580F8X3120831225.94 802-58218X4200801370.02 802-582F28X4120831358.81 802-621110X2100813498.68 802-621F10X2100831488.66 802-623110X3100803498.68 802-623F10X3100831609.18 802-624110X4100813498.68 802-624F210X4100831787.72 802-661112X2100815543.58 802-661F12X2100831890.92 802-663112X3100815543.58 802-663F12X3100832051.81 802-664112X4100815543.58 802-664F12X4100832264.691 Sized with Bushing2 Fiberglass reinforcedTee - Special ReinforcedSocket x Socket x SR Fipt - Stainless SteelCollar802-005SR1/250008616.83 802-007SR3/41512008623.82 802-010SR115008627.96 802-012SR1-1/425008633.30 802-015SR1-1/210008635.17 802-020SR210008668.81 802-030SR350086148.71 802-040SR450086278.86 Tee - Special Reinforced ReducingSocket x Socket x SR Fipt - Stainless SteelCollar802-072SR1/2X1/42515008616.83 802-098SR3/4X1/42510008621.88 802-101SR3/4X1/250008621.88 802-128SR11X1/4108008651.80 802-130SR1X1/250008626.99 802-131SR1X3/415008651.80 802-164SR11-1/4X1/454008655.22 802-166SR1-1/4X1/225008636.61 802-168SR1-1/4X110008637.34 802-207SR11-1/2X1/410008664.44 802-211SR1-1/2X110008640.44 802-212SR1-1/2X1-1/410008640.44 802-245SR12X1/410008674.42 802-247SR2X1/210008674.42 802-248SR2X3/410008674.42 802-287SR2-1/2X1/210008654.86 802-331SR13X1/450086142.10 802-333SR13X1/250086146.23TeesPart Number Size StdPkMstrCtnProdCodeMSRPTee - Special Reinforced Reducing (continued)Socket x Socket x SR Fipt - Stainless Steel Collar802-413SR14X1/450086195.69 802-415SR14X1/250086212.681 Sized with BushingTee - Brass TransitionSocket x Socket x Fipt With Brass Thread Insert802-005BR1/22012008668.79 802-007BR3/42080086137.84 Not intended to convey or dispense water for human consumption through drinking or cookingTee - Brass Transition ReducingSocket x Socket x Fipt With Brass Thread Insert802-072BR1/2X1/42012008674.14 802-101BR3/4X1/250008685.84 Not intended to convey or dispense water for human consumption through drinking or cookingTee - ReducingSocket x Fipt x Socket803-0953/4X1/2X3/450008026.51 Tee - Special Reinforced ReducingSocket x SR Fipt - Stainless Steel Collar xSocket(See also Gauge & Instrument Fittings for additional configurations)803-095SR3/4X1/2X3/415008627.56TeeFipt x Fipt x Fipt805-0021/42515008022.52 805-0033/82515008022.52 805-0051/22024008022.52 805-0073/41512008025.04 805-010*********.30 805-0121-1/410008058.63 805-0151-1/210008071.08 805-020*********.41 805-0252-1/250080278.26 805-030350080290.60 805-040450080472.24Part Number SizePk Ctn CodeMSRPTee (continued)Fipt x Fipt x Fipt805-060F6120801019.09 805-080F8100802007.19 Tee - Special ReinforcedSR Fipt x SR Fipt x SR Fipt - Stainless SteelCollar805-002SR1/42515008619.62 805-003SR3/82515008619.62 805-005SR1/22515008620.23 805-007SR3/42510008622.23 805-010SR115008652.82 805-015SR1-1/210008661.86 805-020SR210008665.02 Tee - StreetSpigot x Socket x Socket844-0051/22520008024.34 844-0073/41512008025.53 844-010*********.92 844-0121-1/410008087.73 844-0151-1/210008087.73 844-0202100080109.6290° Ells90° EllSocket x Socket806-0021/450300080 6.88 806-0033/825150080 6.88 806-0051/220240080 6.88 806-0073/4201600808.82 806-010*********.22 806-0121-1/410008019.04 806-0151-1/225008020.38 806-020*********.62 806-0252-1/25008057.64 806-03036008064.80 806-04045008098.54 806-045F4-1/212083453.07 806-050540080252.63 806-050F514083505.88 806-060640080280.41 806-080820080772.90 806-080F812083776.54 806-10010100813458.96 806-100F10100831380.41 806-12012100814509.01 806-120F12100832256.3390° EllsPart Number Size StdPkMstrCtnProdCodeMSRP90° Ell (continued)Socket x Socket806-14014100825055.59 806-140F14100832878.21 806-160F16100833579.58 806-180F181********.70 806-200F20100836109.23 806-240F24100839381.49 806-33813X250080158.84 806-42214X350080237.27 1 Sized with Bushing90° Ell SweepSocket x Socket806-005S1/22515008017.22 806-007S3/42510008022.28 806-010S120008035.91 806-012S1-1/425008047.53 806-015S1-1/220008051.04 806-020S225008061.86 90° Ell - Long SweepSocket x Socket806-005LSF1/22520008359.70 806-007LSF3/425008367.01 806-010LSF125008374.92 806-012LSF1-1/4250083126.68 806-015LSF1-1/2125083128.30 806-020LSF2110083138.69 806-025LSF2-1/217083238.16 806-030LSF315083259.81 806-040LSF414083291.34 806-060LSF612083446.27 806-080LSF810083935.26 806-100LSF10100831591.33 Not Listed for Electrical Conduit Use90° EllSocket x Fipt807-0021/42545008027.16 807-0033/82515008027.16 807-0051/22024008027.16 807-0073/42024008031.96 807-010*********.58 807-0121-1/4104008039.84 807-0151-1/210008047.56 807-020*********.56Part Number SizePk Ctn CodeMSRP 90° Ell (continued)Socket x Fipt807-030350080147.08 807-040450080277.38 807-0601630080643.59 1 Thread outlet sized with Female Adapter90° Ell - ReducingSocket x Fipt807-1013/4X1/2106008016.47 807-13011X1/2108008026.28 807-13111X3/4108008026.28 1 Sized with Bushing90° Ell - Special ReinforcedSocket x SR Fipt - Stainless Steel Collar807-005SR1/22024008616.14 807-007SR3/475008619.18 807-010SR150008619.39 807-012SR1-1/425008626.09 807-015SR1-1/210008632.21 807-020SR210008636.93 807-030SR35008693.82 807-040SR450086165.7690° Ell - Special Reinforced ReducingSocket x SR Fipt - Stainless Steel Collar807-101SR3/4X1/250008619.12 807-130SR1X1/250008621.4890° Ell - Brass TransitionSocket x Fipt With Brass Thread Insert807-005BR1/22024008660.44 807-007BR3/420160086106.99 Not intended to convey or dispense water for human consumption through drinking or cooking90° Ell - Brass Transition ReducingSocket x Fipt With Brass Thread Insert807-101BR3/4X1/22012008675.40 Not intended to convey or dispense water for human consumption through drinking or cooking90° EllsPart Number Size StdPkMstrCtnProdCodeMSRP90° EllFipt x Fipt808-0021/42545008017.12 808-0033/82515008017.12 808-0051/22012008015.98 808-0073/42024008019.93 808-01011512008025.04 808-0121-1/4104008026.99 808-0151-1/210008038.28 808-020*********.12 808-0252-1/250080167.94 808-030350080270.84 808-040450080476.53 90° Ell - Special ReinforcedSR Fipt x SR Fipt - Stainless Steel Collar808-003SR3/8251500869.43 808-005SR1/2201200869.43 808-007SR3/42012008611.86 808-010SR150008613.82 808-012SR1-1/425008614.73 808-015SR1-1/210008622.99 808-020SR210008625.88 90° Street EllSpigot x Socket809-0051/2502000808.67 809-0073/450008011.04 809-010*********.80 809-0121-1/425008023.82 809-0151-1/210008025.53 809-020*********.82 809-02512-1/25008073.03 809-03035008086.46 809-040440080131.38 809-0601610080373.89 809-08018200801030.53 809-100110100814610.68 809-100F10100831840.61 809-120112*********.17 809-120F12100833008.46 809-140114*********.52 809-140F14100833676.73 809-160F16100833977.36 809-180F181********.48 809-200F20100839568.28Part Number SizePk Ctn CodeMSRP 90° Street Ell (continued)Spigot x Socket809-240F241008314867.64 1 = Assembled with Molded Components90° Street EllMipt x Fipt812-0021/45030008036.86 812-00511/22515008030.59 812-0073/42515008034.74 812-0101150008047.24 812-01211-1/410008054.28 812-01511-1/210008088.92 1 Sized with AdapterNon 90° Ells11-1/4° EllSocket x Socket811-005F1/215208355.89 811-007F3/412008356.28 811-010F115008361.56 811-012F1-1/412608366.69 811-0151-1/225008055.74 811-020*********.33 811-025F2-1/212508381.71 811-0303100080175.19 811-040440080314.84 811-045F4-1/2118083178.01 811-050F514083213.50 811-060F6110083218.49 811-080F814083357.64 811-100F1012083633.84 811-120F1212083926.40 811-140F14100831418.23 811-160F16100831895.80 811-180F181********.34 811-200F20100834222.22 811-240F24100835037.4930° EllSocket x Socket815-005F1/212508355.89 815-007F3/412508356.28 815-010F113008361.56 815-012F1-1/411508366.69 815-015F1-1/212508367.61 815-020F212508373.73 815-025F2-1/211808381.71Non 90° EllsPart Number Size StdPkMstrCtnProdCodeMSRP30° Ell (continued)Socket x Socket815-030F312008389.12 815-040F416083116.84 815-045F4-1/2118083178.01 815-050F514083213.50 815-060650080396.38 815-080F813083357.64 815-100F1012083633.84 815-120F1212083926.40 815-140F14100831418.23 815-160F16100831895.80 815-180F181********.33 815-200F20100834222.22 815-240F24100835037.49 22-1/2° EllSocket x Socket816-0051/22024008015.34 816-0073/42024008023.39 816-01012016008035.06 816-010F112508333.82 816-015F1-1/212508358.97 816-0121-1/420008044.63 816-0151-1/220008052.77 816-020*********.33 816-0252-1/250080140.43 816-025F2-1/211808381.71 816-030350080175.19 816-040440080314.84 816-045F4-1/2118083178.01 816-050F518083213.50 816-060640080396.38 816-060F618083218.49 816-080840080859.60 816-080F814083357.64 816-100F1012083633.84 816-120F1212083926.40 816-140F14100831418.23 816-160F16100831895.80 816-180F181********.34 816-200F20100834222.22 816-240F24100835037.49 45° EllSocket x Socket817-0021/42545008024.80 817-0033/85030008024.80 817-0051/22024008012.98Part Number SizePk Ctn CodeMSRP 45° Ell (continued)Socket x Socket817-0073/42024008019.87 817-01011512008029.77 817-0121-1/4108008037.92 817-0151-1/210008044.84 817-020*********.14 817-0252-1/250080122.08 817-030350080148.62 817-040450080267.57 817-045F4-1/212083185.37 817-050540080320.13 817-050F514083252.96 817-060640080336.97 817-080820080730.60 817-10010100812300.20 817-100F1012083970.76 817-12012100812967.10 817-120F12100831365.72 817-14014100823483.84 817-140F14100832226.08 817-160F16100832725.26 817-180F181********.07 817-200F20100834556.18 817-240F24100835643.5615° EllSocket x Socket818-005F1/212508355.89 818-007F3/412308356.28 818-010F112008361.56 818-015F1-1/212508367.61 818-020F212508373.73 818-025F2-1/2118083240.69 818-030F313508389.12 818-040F4120083116.84 818-045F4-1/2118083178.01 818-050F514083213.50 818-060F618083218.49 818-080F814083357.64 818-100F1012083633.84 818-120F1212083926.40 818-140F14100831418.23 818-160F16100831895.80 818-180F181********.34 818-200F20100834222.22 818-240F24100835037.4945° EllFipt x Fipt819-0021/42545008028.16Non 90° EllsPart Number Size StdPkMstrCtnProdCodeMSRP45° Ell (continued)Fipt x Fipt819-0033/82515008028.16 819-0051/22515008025.68 819-0073/4106008027.58 819-0101106008034.61 819-0121-1/4108008052.78 819-0151-1/210008066.36 819-020*********.39 819-0252-1/250080194.67 819-030350080313.13 819-040450080449.30 45° Ell - Special ReinforcedSR Fipt x SR Fipt - Stainless Steel Collar819-005SR1/22515008614.82 819-007SR3/42530008616.22 819-010SR1106008626.82 60° EllSocket x Socket824-005F1/217083155.12 824-007F3/4125083183.14 824-010F1125083199.26 824-012F1-1/4116083203.17 824-015F1-1/2116083217.02 824-020F2116083275.31 824-025F2-1/2110083324.11 824-030F314083324.73 824-040F414083417.23 824-060F612083745.18 824-080F812083903.16 824-100F10120831543.11 824-120F12100832015.52 824-140F14100832509.76 824-160F16100832835.76 824-180F181********.89 824-200F20100835540.52 824-240F24100839239.07 45° Street EllSpigot x Socket827-0051/25040008012.98 827-0073/450008019.87 827-010*********.77 827-0121-1/425008037.92 827-0151-1/225008044.84Part Number SizePk Ctn CodeMSRP 45° Street Ell (continued)Spigot x Socket827-020*********.14 827-02512-1/212008076.67 827-0303100080148.62 827-040450080267.57 827-050F512083323.72 827-060640080396.38 827-080820080859.60 827-100110100812706.21 827-120112*********.72 827-140F14100832054.62 827-160F16100833295.88 827-180F181********.46 827-200F20100834847.16 827-240F24100837707.37 1 = Assembled with Molded Components22-1/2° Street EllSpigot x Socket842-0051/25040008015.91 842-0073/450008024.49 842-010*********.46 842-0121-1/420008047.90 842-0151-1/225008054.28 842-020*********.33 842-0252-1/250080178.43 842-030350080195.88 842-040440080344.46 842-040F415084219.46 842-060660080489.58 842-060F616083275.31 842-0808120801058.48 842-080F814083363.34 842-100F1010083742.57 842-120F1212084967.57CrossesCrossSocket x Socket x Socket x Socket820-0021/42515008096.03 820-0051/250008096.03 820-0073/4500080101.03 820-0101500080118.31 820-0121-1/4250080141.96 820-0151-1/2250080153.02 820-0202100080189.49 820-0252-1/2100080258.36 820-030350080322.23 820-040430080560.66CrossesPart Number Size StdPkMstrCtnProdCodeMSRPCross (continued)Socket x Socket x Socket x Socket820-060F6100831347.24 820-080F8100831969.94 820-100F10100833177.33 820-120F12100834474.42 820-140F14100837191.16 820-160F16100838149.83 820-180F181********.39 820-200F201008312447.26 820-240F241008318704.54 Cross - ReducingSocket x Socket x Socket x Socket820-10113/4X1/2500080111.29 820-13011X1/2250080144.19 820-1311X3/4200080144.19 820-16611-1/4X1/2250080138.49 820-1671-1/4X3/4250080127.79 820-16811-1/4X1250080182.10 820-20911-1/2X1/2200080206.53 820-2101-1/2X3/4150080206.53 820-21111-1/2X1250080206.53 820-21211-1/2X1-1/4250080206.53 820-24712X1/2100080264.93 820-24812X3/4100080264.93 820-24912X1100080264.93 820-25012X1-1/4100080264.93 820-25112X1-1/2100080264.93 820-2892-1/2X1150080264.93 820-29012-1/2X1-1/4100080388.11 820-29112-1/2X1-1/2100080388.11 820-29212-1/2X240080388.11 820-33513X140080526.30 820-33613X1-1/440080526.30 820-33713X1-1/240080526.30 820-33813X240080526.30 820-33913X2-1/240080526.30 820-42014X230080845.58 820-420F4X214083825.79 820-42214X330080845.58 820-527F6X1-1/212083979.86 820-528F6X2140831045.56 820-530F6X3120831099.22 820-532F6X4120831310.18 820-533F6X5120831553.34 820-578F8X2120831349.19 820-580F8X3100831420.29 820-582F8X4100831466.86 820-585F8X6100831585.13 820-621F10X2100831796.03Part Number SizePk Ctn CodeMSRP Cross - Reducing (continued)Socket x Socket x Socket x Socket820-622F10X2-1/2100831846.34 820-623F10X3100831947.42 820-624F10X4100832021.44 820-626F10X6100832115.43 820-628F10X8100832720.53 820-661F12X2100832009.42 820-663F12X3100832164.90 820-664F12X4100832304.07 820-666F12X6100832675.62 820-668F12X8100833196.19 820-670F12X10100832173.78 820-691F14X2100832883.31 820-693F14X3100833103.03 820-694F14X4100833407.03 820-696F14X6100833763.12 820-698F14X8100834280.78 820-700F14X10100834946.01 820-702F14X12100835594.37 820-751F16X2100833607.10 820-753F16X3100833884.57 820-754F16X4100834309.28 820-756F16X6100834660.61 820-758F16X8100835212.84 820-760F16X10100835680.43 820-762F16X12100836380.10 820-764F16X14100837990.12 820-784F18X4100836082.96 820-786F18X6100836348.99 820-788F18X8100836813.63 820-790F18X10100837277.97 820-792F18X12100837621.12 820-794F18X14100838074.88 820-796F18X16100838413.97 820-814F20X4100837627.49 820-816F20X6100838785.79 820-818F20X8100838884.48 820-820F20X10100839498.20 820-822F20X121008310184.58 820-824F20X141008311372.04 820-826F20X161008311593.79 820-828F20X181008312220.06 820-904F24X4100839106.12 820-906F24X6100839679.12 820-908F24X81008310057.10 820-910F24X101008310200.77 820-912F24X121008310666.74 820-914F24X141008312691.98 820-916F24X161008313553.70 820-918F24X181008315551.56 820-920F24X201008318595.20 1 Sized with BushingPage 13See MSRP-1 Sheet or Check Spears®****************************.comforPricingCouplingsCodeRepair Coupling- FabricatedGasket x GasketCoupling - No StopSocket x Socket - No Pipe Stop0811360.07CouplingSocket x Socket(continued)0832593.64Coupling - ReducerSocket x SocketMade in the U.S.A.Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gasSee MSRP-1 Sheet or Check Spears®****************************.comforPricing Page 14CouplingsPart Number Size StdPkMstrCtnProdCodeMSRPCoupling - Reducer (continued)Socket x Socket829-491F5X4-1/2110083179.47 829-52816X260080619.33 829-52916X2-1/240080742.72 829-53016X3120080625.69 829-530F6X3110083233.50 829-5326X440080504.51 829-534F6X4-1/215083204.10 829-533F6X515083214.03 829-579F8X2-1/216083807.89 829-580F8X316083592.16 829-5828X4200801528.04 829-582F8X416083552.59 829-583F8X514083607.42 829-5858X6200801528.04 829-621F10X212083953.18 829-623F10X312083892.37 829-624F10X412083842.19 829-625F10X514083765.78 829-62610X6100811788.90 829-626F10X614083690.16 829-62810X8100811788.90 829-628F10X814083359.18 829-663F12X3120831375.86 829-664F12X4120831175.32 829-665F12X5120831090.40 829-666F12X6100831016.69 829-66812X8100812035.61 829-668F12X810083787.21 829-670F12X1010083531.79 829-691F14X2100831253.41 829-694F14X4100831354.11 829-696F14X6100831446.44 829-698F14X8100831323.59 829-700F14X10100831294.54 829-702F14X1210083776.46 829-754F16X4100832542.51 829-756F16X6100832299.49 829-758F16X8100832019.58 829-760F16X10100831793.88 829-762F16X12100831512.08 829-764F16X14100831147.82 829-783F18X3100835516.88 829-784F18X4100835364.63 829-786F18X6100835014.70 829-788F18X8100834748.09 829-790F18X10100834295.18 829-792F18X12100833535.44 829-794F18X14100832393.36 829-796F18X16100832043.28 829-814F20X4100835311.04 829-816F20X6100834889.99Part Number SizePk Ctn CodeMSRP Coupling - Reducer (continued)Socket x Socket829-818F20X8100834673.89 829-820F20X10100834509.97 829-822F20X12100833901.50 829-824F20X14100833891.22 829-826F20X16100833574.47 829-828F20X181********.87 829-904F24X4100838495.49 829-906F24X6100838366.14 829-908F24X8100838184.84 829-910F24X10100837987.41 829-912F24X12100837266.14 829-914F24X14100836702.06 829-916F24X16100836107.99 829-918F24X181********.21 829-920F24X20100835267.91 1 Sized with BushingCoupling - Eccentric ReducerSocket x Socket829-101FE3/4X1/225008380.59 829-130FE1X1/211608356.52 829-131FE1X3/415008382.94 829-168FE1-1/4X111208365.72 829-209FE21-1/2X1/2125083104.11 829-210FE21-1/2X3/4125083107.76 829-211FE1-1/2X112508370.60 829-212FE1-1/2X1-1/412008368.29 829-249FE2X112508397.36 829-250FE2X1-1/412508390.46 829-251FE2X1-1/211008386.32 829-289FE22-1/2X1112083103.51 829-290FE22-1/2X1-1/4120083134.11 829-291FE22-1/2X1-1/2120083130.36 829-292FE2-1/2X2110083100.68 829-335FE23X1120083132.09 829-336FE23X1-1/4110083127.20 829-337FE23X1-1/2110083122.22 829-338E3X2150080131.29 829-338FE3X212008378.07 829-339FE3X2-1/2110083253.49 829-417FE34X1118083321.04 829-418FE34X1-1/4110083315.33 829-419FE34X1-1/2112083305.31 829-420FE24X2110083213.17 829-421FE24X2-1/216083177.77 829-422FE4X3110083266.52 829-490FE5X418083214.51 829-528FE36X216083377.82 829-529FE36X2-1/216083344.83 829-530FE26X316083332.81 829-532FE6X415083240.96Page 15Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gas Spears ® Manufacturing CompanySee MSRP-1 Sheet or Check Spears ®****************************.comforPricingCouplingsPart Number SizeStd Pk Mstr Ctn Prod CodeMSRPCoupling - Eccentric Reducer (continued)Socket x Socket 829-533FE 6X515083222.21829-575FE 58X110083770.73829-577FE 58X1-1/210083859.60829-578FE 48X214083876.44829-580FE 38X312083510.22829-582FE 28X412083416.78829-583FE 28X512083415.88829-585FE 8X614083320.48829-624FE 310X410083705.23829-625FE 310X510083802.90829-626FE 210X612083699.57829-628FE 10X812083553.04829-664FE 412X4100831078.44829-666FE 312X610083887.53829-668FE 212X810083766.80829-670FE 12X1012083490.12829-696FE 314X6100831756.77829-698FE 214X8100831444.68829-700FE 14X10100831198.20829-702FE 14X1210083769.77829-756FE 416X6100833245.70829-758FE 316X8100832972.12829-760FE 216X10100832162.14829-762FE 216X12100831919.61829-764FE 16X14100831486.87829-786FE 518X6100834480.40829-788FE 418X8100834288.91829-790FE 318X10100834007.89829-792FE 318X12100833577.34829-794FE 218X14100832949.31829-796FE18X1610832877.82CouplingFipt x Fipt 830-0021/42545008014.98830-0033/82515008014.98830-0051/22515008013.96Part NumberSizePk Ctn CodeMSRPCoupling (continued)Fipt x Fipt 830-0073/42530008019.94830-0101159008021.42830-0121-1/41012008026.49830-0151-1/2108008058.90830-020*********.86830-0252-1/250080147.67830-030350080173.14830-040450080299.83830-060F 618083377.89830-080F 816083555.69830-100F1012083755.79Coupling - Special ReinforcedSR Fipt x SR Fipt - Stainless Steel Collar 830-005SR 1/2251500867.71830-007SR 3/42515008610.97830-010SR 12520008611.72830-012SR 1-1/41012008614.63830-015SR 1-1/2108008632.33830-020SR21008633.89Coupling - ReducerFipt x Fipt 830-07211/2X1/45030008018.83830-07311/2X3/82515008018.83830-1013/4X1/25020008016.62830-21111-1/2X1104008081.081Sized with BushingCoupling - Special Reinforced ReducerSR Fipt x SR Fipt - Stainless Steel Collar 830-101SR 3/4X1/2502000869.97830-130SR 1X1/250008614.80830-131SR 1X3/42520008614.80830-168SR 1-1/4X125008631.78830-210SR 1-1/2X3/425008647.23830-211SR 1-1/2X1108008647.23830-212SR 1-1/2X1-1/4108008647.23830-249SR 2X125008662.60830-251SR2X1-1/210008662.60Grooved Coupling AdapterGroove x Socket 833-0121-1/4106008034.69833-0151-1/2108008038.77。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
课后作业课程名称:计算机辅助焊接技术作业名称:PVCAD软件班级:焊接132601姓名:赵瑞学号:201326060135目录前言 (1)一、概述 (1)二、运行环境、安装与启动 (2)三、焊接零部件数据输入 (3)四、固定管板换热器 (4)五、U形管换热器 (4)六、浮头式换热器 (5)七、立式容器 (6)八、带夹套搅拌容器 (7)九、卧式容器 (7)十、球罐 (7)十一、塔器 (8)参考文献································································································································错误!未定义书签。
前言化工设备CAD施工图软件包(以下简称为PVCAD)是以化工设备设计行业的调查为基础,于一九九○年四月在全国化工设备设计技术中心站召集了有关单位,经过了可行性研究后,报化学工业部立项,并着手开始编制工作。
一九九一年正式由原化学工业部基建司“(91)化基标字第21号92-26”下达此开发项目。
PVCAD将现行化工设备设计行业标准中GB、JB、HG、HGJ、CD等标准编制在本软件包内,同时将一些常用的非标零部件也收集在内,结合行业制图标准形成一套能满足工程实际的卧式容器、立式容器、填料塔、板式塔(筛板塔、浮阀塔)、固定管板兼作法兰换热器(立式、卧式)、固定管板不兼作法兰换热器(立式、卧式)、U型换热器(立式、卧式)、浮头换热器、带夹套搅拌反应器和球罐等十大类设备的绘图软件包。
一、概述(一)软件基本功能PVCAD V3.1是一个帮助压力容器设计人员进行设备详细施工图绘制的软件。
本软件能画出的设备施工图包括:卧式容器、立式容器、带夹套和搅拌的立式容器、球罐、塔器(填料塔、筛板塔、浮阀塔)、管板延长部分兼作法兰和不兼作法兰的固定管板换热器、U形管换热器和浮头式换热器。
对这些设备,本软件能画出总装图和各零部件图。
PVCAD V3.1共有14个程序组成(见表1.1)。
表1.1 PVCAD V3.1 程序内容和对应的数据文件后缀名6浮阀塔09col7筛板塔091col8管板延长部分兼作法兰的卧式固定管板换热器04fix9管板延长部分兼作法兰的立式固定管板换热器041fix10管板不兼作法兰的卧式固定管板换热器05fix11管板不兼作法兰的立式固定管板换热器051fix12卧式U形管换热器06uex13立式U形管换热器061uex14浮头式换热器W07fex当输入了整个设备中所有零部件的结构数据和必要的操作数据后,程序将进行数据处理并形成图形数据文件,然后自动启动AutoCAD,使之装载该图形数据文件,从而直接形成图形。
在AutoCAD形成图形以后,用户可在不退出AutoCAD的情况下,通过选中某个零部件并输入该零部件的数据后,在图形中添加零部件。
(二)软件结构本软件除了以上提及的14个设备绘图程序之外,还包含许多零部件标准数据和其它数据库文件、绘图所需的基本图块文件以及启动AutoCAD所需的命令文件和字库文件,见图1.1所示。
图1.1 PVCAD V3.1 程序结构二、运行环境、安装与启动(一)PVCAD V3.1的运行环境为了使PVCAD V3.1能正常运行,所需要的最低硬件配置为:1、CPU为PII 586/100以上(如CPU和内存取较低的配置也能运行,但在运行AutoCAD时,可能速度很慢);2、内存为32MB以上;3、能支持800×600显示模式的显示卡;4、本软件全部安装将占用约250MB的硬盘空间。
PVCAD V3.1在运行时还需要以下一些支撑软件:1、中文Windows 9x以上版本或西文Windows 9x以上版本加中文之星;2、AutoCAD R14,或R2000,或R2004。
三、焊接零部件数据输入(一)焊接节点图图3.9 焊接节点图数据输入对话框本软件采用的是标准HG20583-1998中的焊接结构形式。
每一个节点图的数据在表格中是一行。
填每一个节点图的数据时,首先需点击图3.9中的“焊接节点图选择”按钮,在所显示的焊接节点形式中选择一种形式。
然后依照图上所示的结构尺寸输入数据。
如要增加一个焊接节点图,可点击“增加”按钮。
如要删除一个焊接节点图,先用鼠标点击所要删除的行,然后点击“删除”按钮。
在选择了焊接结构形式以后,序号栏显示的是所选焊接结构形式在HG20583-1998中的序号。
要输入某一个数据,需用鼠标点击该数据所在列和该节点图序号所在行交会的那一格,然后用键盘进行输入。
所输入的值会同时在表格和输入数据行中显示。
要修改表格中的任意一个数据,也只需用鼠标点击该数据所在的那一格,然后用键盘进行输入即可。
全部焊接节点图数据输入完毕以后,单击“确认”按钮,退出该对话框。
四、固定管板换热器固定管板换热器的绘图程序共有4个,按延长部分兼作法兰或不兼作法兰、立式或卧式来分。
对于输入数据来说,这四个程序除了在支座数据有所不同外,基本一样。
(一)固定管板换热器程序的运行特点由于一般换热器上的接管只有进、出料管和排液、排气管,由此,总图上的接管布置不考虑画节点图。
在画总图以前,必须首先形成布管图,否则,无法进行总图的数据处理。
五、U形管换热器在PVCAD V3.1中,U形管换热器的绘图程序共有2个,立式或卧式。
对于输入数据来说,这两个程序除了在支座数据有所不同外,基本一样。
(一)U形管换热器程序的运行特点由于一般换热器上的接管只有进、出料管和排液、排气管,由此,总图上的接管布置不考虑画节点图。
在画总图以前,必须首先形成布管图,否则,无法进行总图的数据处理。
六、浮头式换热器(一)浮头式换热器绘图程序可以完成以下方面的换热器施工图:1.管程数:2、4、6,型式如下2. 公称直径:300mm~2600mm(卷制筒体)。
但当绘制公称直径大于2000mm 的换热器时,所用的设备法兰只能为非标法兰;3. 换热管外径系列为:10mm、14mm、19mm、25mm、32mm、38mm、45mm、57mm。
4. 换热管等级:Ⅰ级、Ⅱ级5. 接管类型:公制、英制本程序所绘制的总图图幅可为A0或A1。
除本章提及的零部件之外,其它零部件的数据输入操作请见第三章“公用零部件数据输入”。
(二)浮头式换热器程序的运行特点浮头式换热器程序同固定管板换热器程序一样,在数据输入完毕,画总图以前,必须先要生成布管图数据文件。
而零部件图只有当总图生成以后才允许绘制。
且不象固定管板换热器能在生成总图前,通过进行零部件数据处理后,直接画零部件图,即每次启动程序以后,必须先画一次设备总图,才能画各零部件图。
七、立式容器立式容器绘图程序可绘制带各种内件(如进、出料管、除沫器和内加热盘管),安装有耳式、支承式或支腿式支座的直立式容器。
除此之外,被绘制的容器可带有人孔、手孔、设备法兰、接管、液面计、视镜、加强圈等各种零部件。
(一)立式容器程序的运行特点立式容器程序虽然原则上对封头上安装各类接管的数量没有限制,但在图面布置时,轴线一侧的封头上只能画一个接管,如需安装多于一个的各类接管,其它接管必须以节点图的形式布置在图面上。
图7.1 立式容器程序主屏幕立式容器程序的主屏幕见图7.1。
立式容器程序的数据输入可以通过打开“数据输入”菜单,然后选择各菜单项来进行,也可以通过点击主屏幕上方工具条中的图形按钮来进行。
如不清楚每个按钮所代表的零部件数据输入,可以将光标放到该按钮上,这时在光标下方会出现该按钮所代表的零部件名称。
在数据输入完毕以后,就可以打开“运行”菜单,点击“总图”画设备总图。
在每次启动程序后,必须画过一次设备总图,才能画零部件图(即画过一次设备总图后,“运行”菜单中的“零部件”菜单项才会点亮)。
八、带夹套搅拌容器带夹套搅拌容器程序除了能画立式容器程序所能画的各种零部件之外,还能画带夹套和(或)带搅拌装置的设备。
另外,该程序还能单独画出搅拌装置部件图。
(一)带夹套搅拌容器程序的运行特点带夹套搅拌容器程序的运行特点基本上同立式容器,但由于带夹套搅拌容器同立式容器相比多了夹套和搅拌装置,故在搅拌装置部件图的形成方面与其它设备程序稍有不同。
在本程序中,当用户输入了搅拌装置的所有数据以后,可不必先画设备总图即可画搅拌装置部件图,即菜单项“运行-零部件-搅拌装置--搅拌装置部件图”总是点亮的。
九、卧式容器在卧式容器中可安装的标准零部件包括标准椭圆封头、鞍式支座、接管和管法兰、补强圈、人孔、手孔、视镜、液面计;可安装的非标零部件包括加强圈、加热用蛇管(S 型) 、进料管、各种形式出料管和防涡流挡板。
(一)卧式容器程序的运行特点卧式容器中所能安装的零部件除了进料管、出料管和加热用蛇管之外,大部份都是第三章所述的公用零部件。
只要输入了筒体和封头数据、鞍座数据以及连接件数据后即可以画出设备总图。
在形成一遍设备总图后,才能画零部件图。
卧式容器程序能画的零部件图有筒体上部进料管、防涡流挡板和蛇管加热器。
十、球罐球罐绘图程序采用了设计制造标准规范GB12337-1998“钢制球形储罐”和JB/T4711-92“球形储罐基本参数”,如果需要,也可自行确定球罐基本参数。