便携冷镜式水露点分析仪PPT.
便携式露点仪说明书

CERMAX ISIssue 11, March 2003 Manual No.97046 43Pages1.1 (4)1.2 (5)1.3 ATEX (5)2.CERMAX IS (7)2.1 (7)2.2 (7)2.2.1 (7)2.2.2 (7)2.3 (8)2.4 (8)2.4.1 (8)2.4.2 (9)3. CERMAX IS (10)3.1 (10)3.2 (11)3.3 (11)3.3.1 (12)3.4 (12)3.4.1 (12)3.4.2 DEW POINT( ) (13)3.4.3 PPM(W)( ) ( ) (14)3.4.4 PPM(V) 1b/mmscf g/m3 %RH (14)3.5 (14)3.5.1 (15)3.5.2 (15)3.5.3 (15)3.5.4 (16)3.5.5 (16)3.5.6 (17)3.5.7 (18)3.6 (19)3.6.1 (Test No.) (20)3.6.2 (20)3.6.3 (20)3.6.4 (21)3.6.5 (21)3.6.6 (21)3.6.7 (21)3.6.8 (22)3.6.9 (22)3.6.10 (23)3.6.11 (23)3.6.12 (23)3.7 (24)3.7.1 (25)3.7.2 (26)3.8 (27)3.9 (29)4.1 (31)4.2 (31)4.3 (32)4.4 (32)5. (33)5.1 (33)5.2 CERMAX IS (33)5.2.1 (34)5.2.2 (34)5.3 (35)6. (38)1 (39)2 MICHELL (40)3 CERMAX IS (42)1.CERMAX IS MICHELL LCD -100 20 -120o C~+30o CCERMAX IS CERMAX IS CERMAX IS CERMAX IS DISPLAY 3.6CERMAX IS CERMAX IS ON ( 4.3 )1.1(NPL) UKAS -75 ~+20ºC( 0179) (NIST)MICHELL MICHELL MICHELL 5.01.2BS EN ISO 9001:1994 Baseefa (2001)B.S.I.&Baseefa(2001)1.3 ATEXCERMAX IS ATEX (94/9/EC) Baseefa (2001) Ltd (Notified body 1180) BS EN 50 014T bs en 50 020 C.E.N.E.L.E.C. Ex II 1G EEx ia IIC 155o C (T3) Baseefa 03ATEX0090XCERMAX IS ATEX (94/9/EC) ATEX worker protection Directive (1999/92/EC)( )(Flat Battery)CERMAX IS(Logging memory full or incorrect instrument setup.) CERMAX IS CERMAX IS/ (Sensor over/under range or inaccurate sensor measurement)1)2)3)4.2.CERMAX IS2.1CERMAX IS2.2CERMAX IS2.2.1CERMAX IS 4.2CERMAX IS SWAGELOK 1/8” 0.5~5Nl/min 30MPa(300barg) 90o2.2.2on/off (Default) (Previous)3. CERMAX IS2.3CERMAX IS field mode laboratory mode 3.7 3.7.10 015 2 2 -80CERMAX IS 2LCD2.4CERMAX IS2.4.1CERMAX IS 4CERMAX ISCERMAX ISCERMAX IS CERMAX IS2.4.2CERMAX IS RS232 3.6 3.7 3 CERMAX IS 9 D3. CERMAX IS3.110 USER SETUP DEFAULT( ) PREVIOUS( )DEW POINT,OVER ICENONEo C o FpsigDEFAULT/PREVIOUSCERMAX ISSENSOR ID C123 C45 CALIBRATED 14:04:99SOFTWARE VERSION B1.80.00 I.S.COPYRIGHT MICHELL INSTRUMENTS LTD.1aUSER SETUP: DEFAULT PREVIOUSBATTERY CHECK OK1b3.2(MAIN DISPLAY) (AUXILIARY DISPLAY)2Stable DP @ Pressure 10.2ºC10.2 °C DPWARNING - LOW BATTERY33.7DATE 14:04:97 TIME 14:25NO LOGGED DATA AVAILABLE43.33CERMAX ISMain Display Main option3.3.1MENU3.4.DP PPM(V)PPM(W)g/m 3Ib/mmscf %RH 3.4.1MAIN DISPLAY AUX DISPLAY LOGGING DP °C °F K OVER WATER PPM(V) PPM(W)5aMAIN DISPLAY AUX DISPLAY LOGGINGg/m 3lb/mmscf %RHMAIN DISPLAY AUX DISPLAY LOGGING DP °C °F K OVER WATER PPM(V) PPM(W)63.4.2 DEW POINT( )o C o F KMAIN DISPLAY AUX DISPLAY LOGGING DP °C °F K OVER WATER PPM(V) PPM(W)7 o F0o C OVER WATER0o C OVER WATERMAIN DISPLAY AUX DISPLAY LOGGING DP °C °F K OVER WATER PPM(V) PPM(W) 83.4.3 PPM(W)( ) ( )PPM(W)MAIN DISPLAY AUX DISPLAY LOGGING DP PPM(V)PPM(W) N 2 AIR CO 2 H 2 SF 69 PPM(W) 3.4.4 PPM(V) 1b/mmscf g/m 3 %RH PPM(V) 1b/mmscf g/m 3 %rh3.5%rh%rhAuxiliary OptionsMain Option NoneSet Temp Set Press SensorDisplay DPxPPM(V) xPPM(W) xg/m 3x x x lb/mmscf x xx %RHx xxNone. ( ) NONE( ) 21oCSET TEMP CERMAX IS %rhSET PRESS ( ) Set PressSENSOR. DISPLAY.AUX DISPLAY LOGGING MAIN DISPLAY NoneSet Temp Set Press10aAUX DISPLAY LOGGING MAIN DISPLAY Set Press Sensor Display10b ( ) 3.5.1AUX DISPLAY LOGGING MAIN DISPLAY NoneSet Temp °C °F K Set Set Press11 3.5.2%rh (Set temp)(Set Temp) (Set)AUX DISPLAY LOGGING MAIN DISPLAYNoneSet Temp °C °F K Set Set Press12 F 3.5.3(Set)Maximum allowable values Minimum allowable values +200°C -100°C +392°F -148°F 473K +173KAUX DISPLAY LOGGING MAIN DISPLAY NoneSet Temp°C °F K Set -25 Set Press13 -25 3.5.4%rh Set Press PSIG BARG barkPa kPa kPa(Set Press) (Set)AUX DISPLAY LOGGING MAIN DISPLAY NoneSet TempSet Press PSIG BARG kPa Set 100014 BARG 3.5.5Maximumallowable values Minimum allowable values 5880 PSIG 0 PSIG 400 BARG 0 BARG 40,000 kPa 50 kPaAUX DISPLAY LOGGING MAIN DISPLAY NoneSet TempSet Press PSIG BARG kPa Set 3817 381b/mmscf g/m 3 CERMAX IS 1b/mmscf CERMAX IS 1958 kPa bar0 50psig 10 psig 75~300 psig 25 psig 350 500 psig 50 psig 600 1000 psig 100 psig 1200 1500 psig300 psigCEREMAX 13psig bar kPa 10psig CERMAX IS 540psig 500psig 3.5.6( 3.5.4) AUXILIARY DISPLAY( ) (Sensor)%RHg/m 3 lb/mmscf AT PRESSAUX DISPLAY LOGGING MAIN DISPLAY Set Temp Set PressSensor At Press At Atm16 3.5.7(Auxiliary Display)(Sensor)%RHg/m 3 lb/mmscf PRESSAUX DISPLAY LOGGING MAIN DISPLAY Set Press SensorDisplay Press DP17DP @ Pressure 36.5°C10.2°C DPFIELD MODE CAL DUE 04:9818Set Pressure 550 PSIG 10.2°C DPFIELD MODE CAL DUE 04:98233.6CERMAX IS 1000 10000 PC 3.7(LOGGING)Test No. Interval SamplesStart/StopLOGGING MAIN DISPLAY AUX DISPLAY Test No. TextInterval.20aLOGGING MAIN DISPLAY AUX DISPLAYIntervalSamplesStart/Stop20b ( )3.6.1 (Test No.)0 TEST NO 0 Test No.3.6.215 /-TEXT3LOGGING MAIN DISPLAY AUX DISPLAYTest No.Text QUALITY TESTS 3THIS IS MY TESTInterval.213.6.3LOGGING MAIN DISPLAY AUX DISPLAYTest No.TextInterval 1 2 3 5 10 15 30 45 60 mins223.6.4999 10000LOGGING MAIN DISPLAY AUX DISPLAY Test No. TextInterval Samples 2523 3.6.53.6.6START( )LOGGING MAIN DISPLAY AUX DISPLAY Interval SamplesStart/Stop Stop Start Delay Start 00:0024 3.6.7(Delay Start) (24 ) 8:00am 2 30 10:30 (Delay Start) 9 17:00(5:00pm) (Delay Start)Start/Stop(Delay Start)15LOGGING MAIN DISPLAY AUX DISPLAY Interval SamplesStart/Stop Stop Start Delay Start 14:3025 14:30(2:30pm) 3.6.8CERMAX ISStart/Stop STOPLOGGING MAIN DISPLAY AUX DISPLAY SamplesStart/Stop Stop Start Delay Start 14:3026 3.6.9/ ( )Date 14:04:97 Time 14:48NO LOGGED DATA AVAILABLE273.6.10( 3.7 PC )’None’ / (Stable/Responding) 0= (Stable) 1= (Responding) 3.6.114Enter Sample No:5 14:04:97 17% No Time Frostpoint°C PSIG 75 16:23 -15.38 0.0 76 16.24 -15.40 0.029 5 3.6.12Memory gaugeLOGGING MAIN DISPLAY AUX DISPLAYTest No. 5 TextInterval30Test Pt:5 QUALITY TEST 1 14:04:97 9% No Time Frostpoint°C PSIG 0 16:23 -23.39 0.0 1 16.24 -24.400.0313.7CERMAX IS RS232 9600baud 8data bits 1 start bits 1 stop bit no parity IDCERMAX IS COPYRIGHT MICHELL INSTRUMENT LTD. CERMAX IS UNIT ID FREDSERIAL NO.C123C45SOFTWARE VERSION R190.00HELPCLCK? READ THE REAL TIME CLOCK DATE=xx:xx:xx SET DATE TIME=xx:xx:xx SET TIME LANG=US US SETUP LANG=UK UK SETUPKDLY=xx SET KEY REPEAT DELAY IN 10mS UNITS (DEFAULT 100mS) KRPT=xx SET KEY REPEAT RATE IN 10mS UNITS (DEFAULT 100mS) ERAS CLEAR THE LOGGING MEMORY FIELD SPOT CHECK MODE LABUSELABORATORY MODEID= ENTER A MACHINE ID (MAXIMUM 20 CHARACTERS) LOAD DOWNLOAD LOGGED DATA TO TERMINAL 3.7.1CLCK? DATE IS 16:04:97 TIME IS 16:43:15 DATE=17:04:97 DATE IS 17:04:97TIME=10:30:00 TIME IS 10:30:00 LANG=UK or LANG=US LANGUAGE = UK or LANGUAGE = US FIELD UNIT CONFIGURED FOR SPOT CHECKLABUSE UNIT CONFIGURED FOR EXTENDEDMEASUREMENT MODECERMAX IS 10KDLY=10INITIAL KEY REPEAT DELAY SET TO 100 mS100CERMAX IS 10 100 KRPT=10 KEY REPEAT INTERVALSET TO100 mSPCLOAD DOWNLOADING LOGGINGFILES - PLEASE WAIT…DOWNLOAD SUCCESSFULCERMAX IS ERAS CLEARING THE LOGGINGMEMORY WILL TAKE AFEW SECONDS - PLEASEWAIT….LOGGING MEMORYCLEAREDID=FRED Unit ID is FREDLOCK OKUNLOCK OK3.7.2PC COM1 CERMAX IS RS232CERMAX ISWICDOWS 95 HYPER TERMINALHYPER TERMINAL CERMAX ISHYPER TRMCERMAX ISOKConnect COM1OKCOM1Baud 9600Data bits 8Parity NONEStop bits 1Flow control HardwareOKUNIT ID FREDTest Pt:0 MY TEST 15:04:97No Date Time LB/MMSCF PSIG0 15:04:97 14:59 2.30 1000.01 15:04:97 15:00 2.31 1000.0||8 15:04:97 15:02 2.28 1000.09 15:04:97 15:03 2.28 1000.03.8Cermax ISUKASTest HygrometerGenerated Dew point°CDew pointTemperature°CSensorTemperature°CCorrectionRequired°CExpandedUncertainty°C-39.89 -40.11 -20 +0.22 ±0.26-20.10 -20.31 0 +0.21 ±0.220.39 0.20 21 +0.19 ±0.18Generated Dew point°C Instrument Display°C-40.1 -40.2-20.1 -20.10.2 0.1Cermax IS(Calibration Correction)(Calibration Correction)Ref DP( ) ( )Cermax IS DP(Cermax IS ) Cermax IS ) +20o C~-100o C dp 13 Ref DP Cermax IS DP-20o C~+10o C Ref DP Cermax IS DP3.9CERMAX IS1.2.CERMAX IS 2.4.112 141.2. CERMAX IS LOW BATTERY WARNING MICHELL3.4.4.4.14.2CERMAX ISMICHELLCERMAX IS 1/8” PTFE0.5~5L/min4.34.2CERMAX IS 15~90 CERMAX ISON RESPONDINGRESPONDING STABLE( )84.4CERMAX IS MICHELLCERMAX IS IS5.5.1CERMAX IS UKASCermax IS Cermax ISCERMAX ISCERMAX IS CERMAX IS 5.25.2 CERMAX ISCERMAX ISMICHELL CERMAX IS5.2.1CERMAX IS1. RS2322. 8 363.CERMAX IS4. CERMAX IS 3 3 365.6. 1/8” CERMAX IS7. CERMAX IS MICHELL5.2.21. 1/8”2.3. 1/8”4.5. CERMAX IS6.85.3EPROM EPROM EPROM EPROM5.3.1 2.15.3.2 IC145.3.3 EPROM IC145.3.4 85.3.5SETUPMARKET=USLANG=US5.3.6 CERMAX ISMICHELL36 Cermax IS6.MICHELL3161/8” SWAGELOK240 64 LCD4 40 LCD-100o C~+20 o C-120o C~+30o C-60~+20o C, 1o C-100~60o C; 2o C0.1 o C 3o C , o F, Kppm(v)ppm(w)gm-3lb/mmscf0~20mA 4~20mA10,000 RS2326V2412 14250mm 300mm 150mm3kgIP65 NEMA4-20~+50o C-40~+70o C30MPa0.5~5L/min1MICHELL CERMAX IS MICHELL2 MICHELL Michell Instruments LtdNuffield Close, Cambridge, CB4 1SS, UK Tel: +44 (0)1223 434800Fax: +44 (0)1223 434895email: i nfo@web: Michell Instruments GmbH Industriestrasse 27, D-61381 Friedrichsdorf GermanyTel: +49 6172 5917-0Fax: +49 6172 591799email: info@michell.deweb: www.michell.deMichell Instruments SARL4 rue du Docteur Heulin, 75017 Paris FranceTel: +33 (0)1 42 26 01 24Fax: +33 (0)1 42 26 01 37email: i nfo@michell.frweb: www.michell.frMichell Instruments BVKastanjelaan 18M, 2982 CM RidderkerkThe NetherlandsTel:+31 (0)180 466460Fax:+31 (0)180 415623email: info@michell-instruments.nlweb: www.michell-instruments.nlMichell Italia SRLVia Capecelatro 10, 20148 MilanItalyPhone: +39 (0) 024 047194Fax: + 39 (0) 024 *******E-mail: info@michell.itWeb: www.michell.itMichell Instruments Shanghai OfficeUnit A9112, Jia Hua Shang Wu Zhong Xin 808 Hong Qiao Lu, Xu Hui, Shanghai 200030 P R ChinaPhone: +86 (0)21 6448 0152Fax: +86 (0)21 6447 9417E-mail: michellasia@Michell Japan KKMusashino Center Building, 1-19-18 Nakacho, Musashino Tokyo 180- 0006JapanPhone: +81 422 502600Fax: +81 422 521700E-mail: NokeiKWN@web: 3 CERMAX IS1) 1 2L/mina) CERMAX IS b) CERMAX IS,2) Field Mode( ) Lab Mode( ) USER SETUP:DEFAULT FIELD MODE LAB MODE3)RESPONDINGDEW POINT AT ATMOSPHERIC CERMAX IS4) 3 0.4 STABLE 5~105)MICHELL +86 0 21 64479417 64480152 michellasia@。
BARTEC 5673水露点分析仪操作手册

5.6.9 5.6.10 5.6.11 5.6.12 5.6.13 5.6.14 6 6.1 6.2 6.3 6.4 7 8
Programming___________________________________________ 5-1 General instructions ______________________________________ 5-1 Calling up programming mode ______________________________ 5-2 Selecting and opening the menu ____________________________ 5-3 Editing parameters _______________________________________ 5-4 Selecting the parameter setting _____________________________ 5-4 Selecting the parameters for editiபைடு நூலகம்g __________________________ 5-5 Numerical entries ________________________________________ 5-5 Structure of the programming menu __________________________ 5-6 Program parameters _____________________________________ 5-10 Dimension units ________________________________________ 5-10 Analog outputs _________________________________________ 5-11 Analog inputs __________________________________________ 5-14 Temperature ___________________________________________ 5-14 Pressure ______________________________________________ 5-15 CO2 content ___________________________________________ 5-15 Default values __________________________________________ 5-16 Limits_________________________________________________ 5-17 Date and time __________________________________________ 5-18 Serial output ___________________________________________ 5-19 Assigning a liquid to a channel _____________________________ 5-20 Default curves __________________________________________ 5-21 User specific curves _____________________________________ 5-22 Edit Liqiuid Curves ______________________________________ 5-22 Default curves __________________________________________ 5-22 User specific curves _____________________________________ 5-23 Create a new curve______________________________________ 5-23 Edit a curve ____________________________________________ 5-27 Delete a curve__________________________________________ 5-27 Offset ________________________________________________ 5-28 Cancel offset ___________________________________________ 5-29 Reset configuration to default ______________________________ 5-30 Language _____________________________________________ 5-30 System Information ______________________________________ 5-31 Change Password ______________________________________ 5-32 Maintenance menu ______________________________________ 5-32 Error handling __________________________________________ 6-1 Limit transgressions ______________________________________ 6-1 Warnings_______________________________________________ 6-2 Errors _________________________________________________ 6-2 HELP key ______________________________________________ 6-3 Maintenance ___________________________________________ 7-1 Cleaning the sensor ______________________________________ 7-1 Appendix ______________________________________________ 8-1 List of resistance and side effects for fibre-optic sensor L1660 _____ 8-1 Default liquid characteristic curves in HYGROPHIL F 5673 ________ 8-3 Certifications _____________________________________________9
MBW 373 冷镜露点仪 用户手册说明书

产品规格书冷镜露点仪ISO/IEC 17025 官方授权SCS 0125•校准转移标准•气象参考•基础研究项目•微量湿度测量典型应用MBW隶属于Process Insights(潽洛因思)集团当镜子温度高于0℃时,水蒸气在镜子上凝结为液态水(露水)。
液体凝结层被认为是露点。
对于远低于0℃的镜子温度,水蒸气在镜子上凝结为固体冰(霜)。
固体凝结层被视为霜点。
然而,对于介于0至-20℃之间的镜面温度,冷凝层的状态是不确定的,可以是水或冰,或者如右图所示的二者的某种组合。
霜点™作用低于用户设置的温度时,373的ForceFrost功能会对镜子进行过度冷却,使冷凝层进入固相。
这消除了测量露点或霜点的不确定性。
通过迅速将镜子冷却到-40℃以下,迫使冷凝液凝固,然后迅速将其恢复到先前预测的霜点温度,可以确保结霜。
然后使其在镜面温度保持在0℃以下时维持温度状态。
一旦被迫以这种方式冻结,冷凝将在随后的所有镜子温度继续保持在0℃以下时保持霜冻状态。
在这个温度范围内,如果没有肉眼观察,很难知道系统是在露点、霜点,还是在两者之间的某个地方进行控制。
由于这些状态发生在相同水蒸气含量的气体的不同镜面温度下,所以重要的是确定它属于哪种状态。
由此产生的误差可达3℃。
一个恒定厚度的凝结水层,凝结水没有进一步的净增加或减少,与镜子周围的气体处于动态平衡。
在这种平衡条件下,气体的露点或霜点温度是通过测量镜面的温度来确定的。
如果已知冷凝液为液态,即使在低于霜点的温度下,也应将测得的镜面温度作为露点。
如果已知凝结水以冰或霜的固体形式存在,则将测得的镜面温度作为霜点。
高精度冷镜露点仪冷镜湿度测量法是一种用于测量气体露点或霜点的方法,其工作原理如下:光线照射到抛光的镜面上,镜面的温度由一个热电热泵控制,即珀尔帖元器件。
而光敏接收器测量直接反射的强度。
当镜面清洁干燥时,反射光的强度达到最大值。
相反地,表面凝结有水蒸气的冷镜会散射光,导致直接反射的光减少,信号强度降低。
Optica 系列冷镜式露点仪说明书

Optica 可测量新一代湿度参考标准Optica 系列冷镜式露点仪是 Panametrics 公司的新型产品,其露点、温度和压力测量均可溯源至美国国家标准与技 术研究院 (NIST)。
现在,通过互联网或局域网,您可 以随时随地获得所需的相关数据。
.Optica 可测量•温度•相对湿度 (% RH)•露点/霜点 (Td)•绝对湿度 (m/v)•质量比 (m/m)•体积比 (v/v)•湿球温度 (Tw)•热焓 (h)•水蒸气压力 (e)•压力•报警继电器•模拟输出精密露点仪可作为传递标准,用于校验其它的湿度测 量仪器及传感器。
对于要求高精度和无漂移测量的流 程和实验室应用来说,冷镜式露点仪更是首选的传感 器。
Optica 可配备 5 个完全可交换的冷镜式传感器, 测量范围可达 -80°C 到 85°C (-112°F 到 185°F)露 点,精度为 0.2°C (0.36°F) 甚至更高。
100 Ω RTD 输入 和硅基压力传感器确保了测量的精度,并可将露点转 化为任何公制、英制或用户定义的湿度单位。
通讯s• 以太网端口• Java 网络浏览器• 6 M 数据存储• 存储数据以 ASCII 格式上载• 也可导出到表格中• 实时的“带状图”显示• 彩色 VGA 或 4 x 40 点阵显示屏软件Optica 软件使用简单。
借助直观的下拉菜单,用户 可以选择读数显示、带状图、模拟输出比例、数字通 讯、自我诊断,以及清除和记录数据。
设置值可以保 存在内存中,以便随时从本地加载,或通过以太网端 口远程加载。
实验室或工厂车间环境• 校验实验室• 流程控制• 洁净室• 环境测试舱• 高精度 HVAC 监控• 燃料电池• 热交换器和制冷线圈热量计• 热加工/热处理• 半导体制造• 存储区• 药品检验室• 引擎测试单元和排放测试• 飞机引擎和涡轮功能Optica 能够同时测量露点、温度和压力。
冷镜式露点仪基本原理和露点测量中应该注意的若干问题

冷镜式露点仪基本原理和露点测量中应该注意的若干问题目录1.冷镜式露点仪基本原理 (1)2.露点测量中应该注意的若干问题 (1)2.1 镜面污染对露点测量的影响 (1)2.2 露点仪测量条件的选择 (1)2.3 低霜点测量中的问题 (2)1.冷镜式露点仪基本原理当一定体积的气体在恒定的压力下均匀降温时,气体和气体中水分的分压保持不变,直至气体中的水分达到饱和状态,该状态下的温度就是气体的露点。
通常是在气体流经的测定室中安装镜面及其附件,通过测定在单位时间内离开和返回镜面的水分子数达到动态平衡时的镜面温度来确定气体的露点。
一定的气体湿度对应一个露点温度;一个露点温度对应一定的气体湿度。
因此测定气体的露点温度就可以测定气体的湿度。
由露点可以得到绝对湿度,由露点和所测气体的温度可以得到气体的相对湿度。
露点仪直接给出的量值是露点温度,确切地说应为“热力学露点温度”。
世界气象组织采用的定义是压力为P,混合比为r 的湿空气的热力学露点温度Td,是指在给定的压力下,湿空气被水饱和时的温度。
在这个温度下,湿空气的饱和混合比rw 等于给定的混合比r。
光电露点仪的工作原理可以简单地叙述为:被测气体在恒定的压力下,以一定的流速掠过光洁的用冷氮气致冷的金属镜面,随着温度逐渐降低,镜面达到某一个温度时开始结露(或霜),此时的镜面温度就是露点温度。
仪器通过光学系统,测温电路,逻辑控制电路、数字显示电路等,测量露点温度Td,并显示出来。
2.露点测量中应该注意的若干问题2.1 镜面污染对露点测量的影响在露点测量中,镜面污染是一个突出的问题,其影响主要表现在两个方面:一是拉乌尔效应,二是改变镜面本底散射水平。
拉乌尔效应是由水溶性物质造成的。
如果被测气体中携带这种物质(一般是可溶性盐类)则镜面提前结露,使测量结果产生正偏差。
若污染物是不溶于水的微粒,如灰尘等,则会增加本底的散射水平,从而使光电露点仪发生零点漂移。
此外,一些沸点比水低的容易冷凝的物质(例如有机物)的蒸气,不言而喻将对露点的测量产生干扰。
便携式露点仪 DPT-600

便携式/台式露点仪DPT-600生产厂家:美国菲美特公司介绍:D P T-600便携式/台式露点仪是采用最先进的纳米微孔金属氧化膜露点传感器生产的现场露点分析仪,能够在-110℃~+20℃的露点温度范围内快速准确地测量气体的水分含量。
应用领域:石化、电力、制药、工业气体、热处理、航空、天然气、干燥设备和医疗。
主要特点:轻巧易于携带,同时可用于台式可编程数据记录可充电长寿命锂电池供电带USB数据输出,可选4~20mA电流输出可选PVA仿真软件在PC机上模拟仪器的操作多参数显示:℃(dp)、(dp)、ppmV、ppmW、μB水蒸气压力、克/每立方米、LBS等.BS等技术参数:露点传感器测量范围:-110℃~+20℃精度:±2℃响应时间:3分钟95%的阶跃变化(由干到湿)气体流量:>1L/M温度传感器测量范围:-40℃~+70℃精度:±2℃压力传感器(可选)测量范围:0~150PSIA(10bar)±1%,接触被测气体材质为316L不锈钢流量计材质大部分为苯乙烯丙烯晴,最大压力为3.4Bar(此压力限制是指排气口的压力)人机工程设计易于携带或台式摆放,重量仅为1.6公斤易读的图形,液晶显示,背光亮度用户可调自动缩放趋势图,可用来判断测量值是否稳定内置详细的帮助文件便于用户使用电池省电模式可由用户自定义自动关机时间,也可完全关闭此模式内置的压力测量和压力修正功能,可同时显示常压露点和压力露点用户可选择带或不带密码锁定内置备份电池电源支持的时钟日历数据记录:可记录单点或多点数据,内容包括:露点、温度和压力(内存>4000点)电路提供带有USB接口的通用外置交流电源适配器(100-240VAC50-60Hz)可充电的锂离子电池,用USB接口或电源适配器充电采样系统和传感器与电气接口和接地都是隔离的传感器分辨率:1pF产生小于0.01˚C外部电源和I/O:USB mini B插口,带密封帽达到IP67/IP68防护等级机械进/出器口采用1/8”Swagelok卡套接头内部管路全采用316不锈钢和聚四氟乙烯材质,不锈钢测量腔内部的面积小,便于快速响应仪器外壳采用挤压铝型材,尺寸:199×162×84mm(L×W×H)重量:1.6kg操作温度-20~+60℃应用领域:石化、电力、制药、工业气体、热处理、航空、天然气、干燥设备和医疗。
英国Michell 露点分析仪、便携式湿度计、湿度和温度变送器介绍

英国Michell 露点分析仪、便携式湿度计、湿度和温度变送器介绍Michell Instruments的总部位于英国伊利(Ely),是湿度和湿度测量解决方案领域的供应商。
凭借40多年的经验,Michell为压缩空气、发电、工艺、石油和天然气、制药等广泛的应用和行业,设计和制造种类广泛的露点、湿度和氧气测量变送器、仪表和系统解决方案。
Michell仪器是湿度和湿度测量解决方案领域的国际领dao者。
凭借40多年的经验,Michell设计和制造了一系列变送器、仪器和系统解决方案,能够在压缩空气、发电、工艺、石油和天然气、制药等广泛的应用和行业中测量微量水分、湿度、露点、碳氢化合物露点和氧气含量。
Michell Instruments是过程传感技术(PST)集团的一部分,Michell Instruments是高精度传感领域的国际领dao者,在该领域拥有40年的经验,专门从事露点、相对湿度和氧气分析仪器。
该公司为石化、制药、发电和食品加工等多种行业提供服务。
产品范围包括:高精度陶瓷湿度传感器,用于测量工艺应用中的微量水分。
用于暖通空调应用、药品储存和其他生产过程的相对湿度变送器和传感器,其中受控的环境条件至关重要。
湿度校准系统和参考露点湿度计使客户能够在内部进行便携式湿度计和相对湿度仪器的校准,从而节省停机时间和成本。
氧化锆和热顺磁氧分析仪用于燃烧优化、保持气体纯度、控制啤酒厂的二氧化碳水平以及许多其他应用。
Condumax II碳氢化合物露点分析仪可确保托管移交时的天然气质量,防止燃气燃烧器故障,延长工艺设备的使用寿命,帮助公司节省数百万美元的维修和停机时间。
碳氢化合物液体中的微量水分分析仪有防爆和本质安全两种版本,可在从催化炼油工艺到纯碳氢化合物的广泛应用中连续测量水分含量。
工艺水分分析仪可对工艺气体中的微量水分进行连续在线测量,并可提供防爆、本质安全和实验室版本。
产品包含:1)水分分析仪和碳氢化合物露点分析仪:◇天然气分析仪中的碳氢化合物和水露点参考型号:CDP301 Condumax露点测试仪、Condumax II在线碳氢化合物露点分析仪、Condumax II可运输碳氢化合物和水露点分析仪、Condumax II和OptiPEAK TDL600◇气体中的水分分析仪参考型号:QMA601-过程水分分析仪、OptiPEAK TDL600-天然气水分分析仪、Promet I.S.-过程水分分析仪、Promet EExd-过程水分分析仪、QMA401-微量水分分析仪◇液体水分分析仪:Liquidew I.S.-液体水分分析仪:本质安全液体水分分析仪,提供快速可靠的在线测量。
便携冷镜式水露点分析仪PPT解读

天然气含水汽量表示方法
1、湿度 绝对湿度:单位体积(m3)天然气所含水汽重量(g),用E表示 相对湿度:绝对湿度与相同条件下饱和绝对湿度的比值,Es 2、水露点:天然气在一定压力下结出第一个水露珠时的温度 注意:水的饱和蒸气压随温度降低而降低,相对湿度愈大,水露点 愈高。 天然气水分测定 露点法 测定天然气水露点,可直接查出在该温度下的水的饱和蒸汽压PS 根据道尔顿定律可算出天然气含水量。 V水%=y水=PS/P总
CHANDLER process Instruments
按天然气ห้องสมุดไป่ตู้类组成分类
干气:1基方井口流出物中C5以上重烃液体含 量低于<10cm3。 湿气:1基方井口流出物中C5以上重烃液体含 量高于>10cm3。 贫气:1基方井口流出物中C3以上烃类液体含 量低于<100cm3。 富气:1基方井口流出物中C3以上烃类液体含 量高于>100cm3。 按酸气含量分类 按酸气(硫化物和CO2)含量的多少,天然气可分为酸性气和洁气。 H2S含量>20mg/m3称为酸性气
呈“分散状”。水在镜面上容易凝聚在一起,不易分散。
☆霜点和露点:用等压冷却的方法使被测气样中的水蒸气在一个水平 镜面上开始出现霜或露,此时的镜面温度即为该气样的霜点或露点。 ☆冷壁效应:除镜面外,仪器其余部分和管子的温度应高于气体中水 分露点至少2 ℃,否则,水蒸气将在最冷点凝结,改变了气样中水分 含量 ☆过冷现象 如果样气水分含量低时,冷却镜面时竟可能慢一些,降温速度太快 可能造成“过冷”。我们知道,在一定条件下,水汽达到饱和状态时, 液相仍然不出现,或者水在零度以下时仍不结冰,这种现象称为过 饱和或“过冷”。 4.露点仪维护 · 使用仪器前、后都要进行吹扫,不要留水渍在镜面。 · 清洁镜面上的污染物,不要造成镜面划痕。 · 更换乙二醇过滤芯(白芯变黑)时,注意乙二醇过滤器密封圈完好。 · 保持目镜清晰,便于观察。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
AMETEK process Instruments
·取样管线中不能含有液态水、烃类、甲醇等。 2.2露点仪制冷剂管线连接 ·CO2(制冷剂)瓶——M20X1.5(外)转1/4NPT-1/8NPT(带卡套)— —1/8不锈钢制冷剂管——1/4NPT-1/8NPT(带卡套)接头——快速 安装接头——冷凝器 2.3仪表供电 ·仪器配有电源适配器,初次充电时间为8小时。 ·仪器缺电时会显示9999提示。 3.露点仪测试操作步骤 3.1打开样气入口阀门,吹扫仪器约5分钟。 3.2间断关闭样品气出口阀,调节样品气出口阀,确保气体在满压情 况下连续流过冷却器,调节样品气出口阀,使出口气体流量很小,用 手指尖感觉到即可,流量给为5ml/min。 3.3打开液晶温度显示电源,确认最右边小数点不闪。若小数点在
CHANDLER process Instruments
闪则表明目前温度处于”hold(保持)”状态,温度会一起不变。可按 “hold”键一次,退出“hold”模式,转到活动模式,此时最右边的 小数点不闪。 3.4将制冷剂(液氮)与铜棒少量接触,降低镜面温度,温度降低速 不应大于1-2℃/min. 3.5观察镜面和温度显示,当镜面中心出现米粒大小的白色斑点时, 此时的温度就是露点的温度。 3.6取掉制冷剂,让镜面温度回升,注意白色斑点消失的温度。 3.7重复4~5步,直到观察的露点差在1℃之内,记录观察到的平均温 度作为露点。
1.3测试流程
冷镜式露点分析仪包括一个样品气体可流过的小高压釜(最大 5000PSI),在釜的一端有一个抛光镜面并在另一边有一个观察窗, 操作者通过一个制冷阀调节汽化的制冷气体直到可观察到露点,温
CHANDLER process Instruments
度和压力可记录并绘制在一个曲线图上,以便获得样品的水含量,使 用相同方法也可观察到烃露点。
CHANDLER process Instruments
高压下测量露点,压力容器内壁镶有一圈镜面,镜面用冷凝剂进行冷 却,水分和 烃类物质就可以在镜面上冷凝。水分凝结情况可以通过 压力容器上的小孔来观察。
1.2仪器组成
仪器分类 显示 *Standard 版本-干湿球温度计-直读 * ChanScope 版本-铂电阻温度检测器测量-数字显示 制冷方式 *常规制冷——冷凝器——可汽化的制冷剂 *快速制冷——铜棒——液氮 主机部分: 光学系统 目镜系统 数字显示系统 温度检测系统 制冷系统 配置部分: 取样系统 过滤器 制冷剂 三角支架 便携箱
呈“分散状”。水在镜面上容易凝聚在一起,不易分散。
☆霜点和露点:用等压冷却的方法使被测气样中的水蒸气在一个水平 镜面上开始出现霜或露,此时的镜面温度即为该气样的霜点或露点。 ☆冷壁效应:除镜面外,仪器其余部分和管子的温度应高于气体中水 分露点至少2 ℃,否则,水蒸气将在最冷点凝结,改变了气样中水分 含量 ☆过冷现象 如果样气水分含量低时,冷却镜面时竟可能慢一些,降温速度太快 可能造成“过冷”。我们知道,在一定条件下,水汽达到饱和状态时, 液相仍然不出现,或者水在零度以下时仍不结冰,这种现象称为过 饱和或“过冷”。 4.露点仪维护 · 使用仪器前、后都要进行吹扫,不要留水渍在镜面。 · 清洁镜面上的污染物,不要造成镜面划痕。 · 更换乙二醇过滤芯(白芯变黑)时,注意乙二醇过滤器密封圈完好。 · 保持目镜清晰,便于观察。
2.安装
2.1露点仪样品管线连接 · 天然气管线取样——M20X1.5(外)转1/4NPT-1/8NPT(带卡套)接 头—1/8”取样管线-——1/4NPT-1/8NPT(带卡套)接头——乙二醇 过滤器——针阀——测量室(不锈钢压力容器) · 安装乙二醇过滤芯 提示: · 取样管线为1/8不锈钢管,不能用塑料管。 · 气源和露点测试仪之间不能有压降。 · 管线压力不得高于仪器的额定压力。 · 取样管线和露点测试仪的温度必须高于管线中气体的露点温度。
使用注意事项:
☆干扰物质的影响:污染物妨碍观察。 ☆烃露点出现:(在最高操作压力下,水露点应比最低输送环境温度 低5 ℃ ;在最高操作压力下,烃露点应不大于最低输送环境温度) 烃能在镜面上冷凝,如果烃露点低于水露点,不影响测定。相反情况 下,会先于水蒸气结露,熟悉观察镜面,进行区分:烃不容易凝聚,
CHANDLER process Instruments
便携冷镜式水露点分析仪交流
1.仟德勒冷却镜面露点仪简介 2.露点仪使用安装 3.露点仪测试操作 4.露点仪维护
CHANDLER process理
水含量的各种仪器中,最精确、应用最广泛的就是镜面冷却露点 测试仪。若正确使用这种仪器,所测得的露点精度为±0.1℃。
13-1200型冷镜式露点分析仪是一台直接测量天然气中水份的仪 器,它耐用、便携和并提供0.2F以内的重复性结果,它的原始特性 决定了它无需标定,因此它常被用于检测可靠性较差的电子仪器。 Chandler水露点测试仪符合 ASTM D1142-GPA2140S能满足露点 定义所需的条件。当冷却气、水混合蒸汽(没有液态水存在),水 蒸汽的绝对湿度是个常数,而相对湿度却逐渐增加,直到其饱和度 达到100%,若再继续冷却,水蒸汽就会凝结,发现第一滴凝结水 时的温度就是水露点。本测试仪通过调整上述步骤,使它能使用于
CHANDLER process Instruments
CHANDLER process Instruments
露点测试仪包括密闭容器和阀门,耐压密闭容器用来盛装测试的 气体,阀门用来控制气体的流量,在压力容器的一端,装有一个透明 的塑料小窗孔,可以用它来观察容器的内壁和镜面。镜面是用高度光 滑的不锈钢材料制成的,其中心与铜制的温度计插孔相连,温度计插 孔上装有冷却器,来控制冷凝剂的膨胀和镜面温度,冷凝剂流动的速 度越大,温度降得越低,镜面的温度可有一支温度计显示。ChanScope 版本有使用源于NIST并经过检验的铂电阻式温度检测器和数字显 示屏。