Technics松下 SU-VX500功放维修手册 扫描版

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

R

O

M Service Manual

Stereo Integrated Amplifier

SPECIFICATIONS

(DIN 45 500)

• M AIN AM P. SECTION (POWER AMP. DIRECT Input)

20 Hz 20 kHz continuous power output both channels driven

1 kHz continuous power output both channels driven (THD: 1%)63 H ~ 12.5 kHz continuous power output both channels driven (THD: 0.7%)

2x65 W (8 Ω)2X90 W (4 Ω)

2 x 60 W (8 oM)2 × 80 W (4 Ω)

Total harmonic distortion (Power Amp Direct Input)rated power at 20 Hz~20 kHz 0.007% (8 Ω)half power at 20 Hz ~ 20 kHz 0.005% (8 Ω)Intermodulation distortion (SO Hz: 7 kHz = 4:1. SMPTE)rated power 0.007 % (8 Ω)

Residual hum and noise 0.2 mV

Damping factor 60 (8 Ω). 30 (4 Ω)

Headphones output level and Impedance 540 mV/330 ΩLoad Impedance

A or B, BI WIRING 4Ω 16Ω

Aand B 8Ω 16Ω

PRE AM P. SECTION and impedance Input sensitivity a

PHONO MM 2 5 mV/47 kΩ

PHONO M C 170 µV/220 Ω

TUNER, CD, AUX, TAPE 1, TAPE 2/DAT 150 mV/22 kΩPOWER AM P DIRECT 1 V/18 kΩPhono maximum Input voltage (1 kHz, RMS)M M

160 mV. IM F' 66

M C 12 mV. IMF' 66

Amplifier

SU VX500

Country

Code (E)(EB)(EG)

(GC)

(GN)

Area

Continental Europe Great Britain

F.R. Germany and Italy Asia. Latin America.Middle Near East and Africa Oceania

Color

(K)

S/N (rated power, 4 Ω)

PHONO MM 78 dB (85 dB. IMF' 66)PHONO MC 66 dB (S = 250 µV. 67 dB, IHF` 66)

97 dB (99 dB. IHF'66)106 dB (115 dB, IHF '661POWER AMP DIRECT S/N at ~ 26 dB power (4 Ω)

PHONO MM 76 dB

PHONO MC 66 dB TUNER, CD, AUX, TAPE 1, TAPE 2/DAT 84 dB SIN at 50 mW power (4 Ω)

PHONO MM 75 dB

PHONO MC 66 dB

TUNER, CD, AUX, TAPE 1, TAPE 2/DAT 78 dB

Frequency response PHONO MM RIAA standard curve ±0.8 dB (30 Hz~15 kHz)

TUNER, CD, AUX. TAPE 1, TAPE 2/DAT 3Hz 100kHz(+0, 3dB)+0 dB, 0.2 dB (20 Hz~20 kHz)POWER AMP DIRECT 2 Hz~120 kHz (+0, 3 dB)

+0 dB. 0.2 dB (20 Hz~20 kHz)

Tone controls BASS 50HZ, +10 dB, 10dB TREBLE 20kHz +10 dB, 10 dB Loudness control (volume at 30 dB) 50 Hz. +9 dB Output voltage TAPE 1, TAPE 2/DAT REC OUT 150 mV

Technics

2 x 50 W (8 Ω)

Color

Areas

(K ) Black Type

m

i c r

o SU-VX500

• GENERAL

Power consumption 530 W

Power supply

• for Great Britain and Oceania

F.R. Germany, Italy and Continental Europe:

AC 50/60 Hz. 230/240 V

for Others: AC 50760 Hz. 110 V/127 V/220 V/240 V

• CONTENTS

Dimension. (W x H x D) 430x 125x316 mm

(16-15/16" x4-15/16"x 12-7/16")Weight 8,1 kg (17.82 Ib.)Notes:1. Specifications are subject to change without notice.Weight and dimensions are approximate.2. Total harmonic distortion is measured by the digital spectrum analyzer.Page Page

BEFORE REPAIR AND ADJUSTMENT 2 PRINTED CIRCUIT BOARDS 15-18PROTECTION CIRCUITRY 2 WIRING CONNECTION DIAGRAM 19ACCESSORY 2 BLOCK DIAGRAM 20LOCATION OF CONTROLS 3 MEASUREMENTS AND ADJUSTMENTS 21CONNECTIONS 4-6 REPLACEMENT PARTS LIST 22-24,27DISASSEMBLY INSTRUCTIONS 7-10 CABINET PARTS LOCATION 25 25SCHEMATIC DIAGRAM 11-14 PACKAGING ' 28

I BEFORE REPAIR AND ADJUSTMENT

(1) Tum off the power supply. Using a. 10o M , 10 W resistor, shortcircuit both ends of power supply capacitors C001, C002. C705

and C706 in order to discharge the voltage.(2) Before turning on the power switch of the unit,

A. Connect the voltage controller to the primary side.

B. Connect the AC ampere meter to the primary side or conned the DC voltage meter to the "±B" circuit of the secondary

side.

C. Turn the VR of ICQ (VR451, VR452. VR501 and VH502) to minimum (counterclockwise).

D. Alter setting the output to zero of the voltage controller, turn on the power switch of the unit.

And increase the output of voltage controller gradually.Then, check carefully whether the current value of primary side become more than following value or whether the DC voltage of secondary side is increasing slowly.E. II the value of current is increasing unusually or the DC voltage is not increasing, lower the output level of voltage controller Immediately.•The current value of the primary side at no signal. (Confirm the power supply voltage ot each area and provided voltage of

the unit.)

Power supply voltage Consumed current

50 Hz

AC 1 1 0 V

250-540 mA

AC 120V

210-500 mA

AC 220V 90-370 mA

AC 230 V

80-360 mA

AC 240 V

70-350 mA

I PROTECTION CIRCUITRY

The protection circuitry of the amplifier may have operated if either of the following conditions is noticed:

•No sound Is heard when the power is turned on.•Sound stops during a performance.

The function of this circuitry is to prevent circuitry damage if, for example, the positive and negative speaker connection wires are "shorted", or if speaker systems with an impedance less than the indicated rated Impedance of the amplifier are used.

It this occurs, follow the procedure outlined below:1. Turn off the power.2. Determine the cause of the problem and correct it.3. Turn on the power once again.

Note:

When the protection circuitry functions, the unit will not operate unless the power is first turned off and then on again.

I ACCESSORY

•AC power supply cords

For (E), (EG) areas. For (EB) area only. For (GC) area only. For (G N ) area only.

-2-

相关文档
最新文档