最新KEDY-5000智能一体化电源系统
开拓者(KITOZER)mdc智能一体化机柜

2
MDC柜 随着大数据时代的到来,云计算、移动互联和物联网等产业蓬勃
发展,数据中心规模不断增大并呈现两极化发展趋势,末端的微型数 据中心越来越多。而零星分布的微型数据中心因地理、环境、建筑等 方面的差异,一直面临着难以统一规划、建设和运维管理的窘境,为 业务的快速上线带来了极大的挑战。
1
MDC 智能一体化机柜
目录 一、什么是智能一体化机柜 .................................................................. 3 二、KITOZER(开拓者)智能一体化机柜优势 ........................................ 5 三、用户价值 .........................................................................................7 四、应用场景 .........................................................................................8 五、智能一体化机械柜组成部分(产品配置) ................................... 9 六、智能一体化机柜(MDC)分类: ................................................... 10 七、智能一体化机柜系统特点: ........................................................ 10 八、智能一体化机柜系统功能 ............................................................ 12 九、智能一体化机柜解决应用 ............................................................ 16 十、单柜数据中心(小型 MDC 模块化数据中心解决方案) ..............16 十一、联柜数据中心 (中型 MDC 模块化数据中心解决方案)......21 十二、一体化机柜产品规格 ................................................................ 25 十三、一体化机柜结构特点 ................................................................ 31 十四、设备技术参数............................................................................ 34 十五、机架式机柜式精密空调 ............................................................ 44 十六、机架式配电单元........................................................................ 47 十七、一体化机柜悬挂式感温型七氟丙烷灭火装置 ......................... 48 十八、机架式 UPS 主机 .......................................................................53 十九、智能一体化机柜配置清单 ........................................................ 57
JB-TG-TC5000控制器安装说明书

JB-TG—TC5000火灾报警控制器(联动型)安装使用说明书Ver 1。
0,2014。
07辽宁·营口天成消防设备有限公司第一章JB—TG-TC5000火灾报警控制器(联动型)简介 (5)第二章结构及配置说明 (6)2。
1控制器典型配置及内部结构概述 (6)2.2控制器面板说明 (7)2.3内部结构及连线说明 (9)2.3.1控制器结构说明 (9)2。
3。
2控制器对外接线端子说明 (9)第三章安装与调试 (10)3.1 开箱检查 (10)3.2 机箱的安装条件及方式 (10)3。
3 开机检查 (10)3.4 外部设备检查 (10)3.5 接线和设置 (11)3。
6 调试 (11)第四章一般性用户使用说明 (12)4.1开机、关机与自检 (12)4。
2键盘操作前准备 (12)4.2.1键盘的命令功能和字符功能 (12)4.2.2数据输入的一般方法 (12)4.2.3信息查看操作的一般方法 (13)4.3操作等级 (13)4.4设备登记与登记检查 (13)4。
4。
1设备登记 (13)4.4。
2登记检查 (13)4.4。
3检查回路配置 (13)4.5信息显示与记录 (16)4。
5.1信息显示 (16)4.6消音 (17)4.7火警及故障的处理 (18)4。
7。
1故障的一般处理方法 (18)4。
7。
2火警的一般处理方法 (18)4。
8设备的屏蔽与解除 (18)4。
8.1设备屏蔽 (18)4。
8.2取消屏蔽 (18)4。
9总线制被控设备的手动启动与停止操作 (19)4。
9。
1对外部设备进行手动启动操作的条件 (19)4.9。
2利用主机键盘进行的被控设备启动/停动操作 (19)4.9.3利用总线控制盘进行的被控设备手动启动/停动操作 (20)4。
10总线制被控设备的自动联动控制 (20)4.10。
1实现自动联动的条件 (20)4.10。
2自动联动逻辑的实现 (20)4.11复位功能 (21)第五章系统管理员操作指南 (21)5.1修改时间 (21)5.2 屏蔽设定 (21)5.3打印方式设置 (21)5。
海湾联动控制器操作说明书

底图总号旧底图总号媒体编号一般性用户使用说明 系统管理功能说明第五章一般性用户使用说明5.1开机、关机与自检当调试工作完成后,用户就可以按以下顺序进行开机操作了:✧打开联动电源和火灾显示盘电源的主备电开关。
✧打开主机电源的主备电开关。
✧打开控制器的工作开关(在DC-DC 变换模块上)。
完成以上操作后,系统上电进行初始化(画面显示如图5-1所示)。
初始化完成后进入对运行记录、隔离信息、联动公式、声光电源的自动检查状态(画面显示如图5-2所示),自检完毕,控制器对外接火灾显示盘、探测器和模块进行注册(如图5-3所示),并显示注册信息(如图5-4所示)。
至此,开机过程结束,系统进入正常监控状态。
主机键盘上设有“自检”键,按下此键后系统将进行和开机时相同的声光及电源检查。
关机过程按照与开机时相反的顺序关掉各开关即可。
要注意各个备电开关一定要关掉,否则,将有损坏电池的可能。
GST5000V3.0界面题头底图总号旧底图总号媒体编号图5-1图5-2图5-3GST5000V3.0GULFSECURITY TECHCO.,LTD 。
GST2.00.12系统自检运行记录检查通过隔离信息检查通过联动公式检查通过声光电源检查GST5000V3.0GULFSECURITY TECH CO.,LTD 。
注册在役设备请稍等……注册信息浏览系统当前设备配置底图总号旧底图总号媒体编号图5-45.2键盘操作前准备5.2.1键盘的命令功能和字符功能控制器的键盘多数为双功能键,下部标识为命令功能,上部标识为字符功能。
命令功能,只在监控状态下起作用,并且多数功能键受锁键功能限制;字符功能,只在进入菜单后,才可进行数据输入。
5.2.2数据输入的一般方法在开始输入数据时,屏幕上会有一个区域高亮提示当前数据输入的位置和范围。
按下字符键,高亮和高亮区内原来显示的字符消失,从该字符开始重新输入;按“下移”或“上移”键,高亮条消失,光标停在原高亮区显示的第一个或最后一个字符处,进入数据编辑状态。
技术对比------GTL

测试距离r 波形采样
fs 激光器光学
THz 通道 THz A/D THz 内部连接
缆线 配件 I/O 配件电源
配件电源 编码器输入 离散 I/O 端
通信 本地连接 千兆以太网口 辅助 I/O 本地显示 外部指示器 外形尺寸
重量 安装 交流电源 工作环境 工作震动 光学振动
规范
安全标准
类型 2(通用 Snub) HTS40x2 HRX40x1 Y
1,3 或 6inch 焦距,1.5inch 直径 高密度聚乙烯,ቤተ መጻሕፍቲ ባይዱ球面镜头
出厂固定 5 m 长度 UMA5001 320 ps 100 / s
(Min) 0.05 THz (Max) 3.5 THz (Max)取决于用户光学条件 取决于客户感兴趣区域
TCU5220
TCU5221
TCU5222
TCU5223
TCU5210
TCU5211
TCU5212
TCU5213
320ps
80ps
160ps
700ps
320ps
80ps
160ps
700ps
100/s
1,000/s
1,000/s
100/s
100/s
1,000/s
1,000/s
100/s
<±25fs
无
可调节
兼容性
所有 T-Ray 5000 R&D 和无损评估成像和波谱学配件;所有单机 T-Ray5000 和 T-Ray4000 系列太赫兹发射器、接收器和收发器;所有 T-Gauge 工业传感器和成像配件。
TCUTM 系列 功能等级
TCU 服务器 T-Ray 基础分析
三里电源5kVA智能线上RM UPS 5000VA双转换电源说明书

SmartOnline 208/240V 5kVA 3.5kW Double-Conversion UPS, 5U Rack/Tower, Extended Run, Network Card Options, DB9 SerialMODEL NUMBER:SU5000RT3UHVDescriptionTripp Lite 5kVA Smart Online RM UPS. 5000VA on-line, double-conversion UPS for server, network and telecommunications equipment. Maintains battery derived AC output during blackouts with active, full-time power conditioning. Fault-tolerant auto-bypass prevents unexpected service interruptions during overload or internal fault conditions. 3U power module and 2U battery pack install in 5 rack spaces. Full-time sine wave output within 2% of selectable 200/208/220/230/240V AC. Corrects brownouts to 156V and overvoltages to 276V. Frequency regulation locks output power to 50/60Hz (+/-0.2%)/Expandable runtime with optional rackmount external battery packs. Double-conversion UPS converts raw input from AC to DC, then back to perfect sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types. Highly efficient operation in optional economy mode setting, saving BTU heat output and energy costs. Network-grade AC surge and noise suppression. Network management interfaces include 2 DB9 ports and slot for network management card options. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network interfaces. PowerAlert monitoring software is available via free download. Emergency Power Off (EPO) interface. Front panel LEDs and LCD readout with scroll controls support visual monitoring of all major UPS functions. Audible alarm. Self test. 4-post rackmount accessories included; 2-9USTAND and 2POSTRMKITHD accessories available. L6-30P plug-in connection; built-in L6-30 & L6-20 outlets. Power Distribution Unit (PDU) options supported. Field-replaceable, hot-swappable external battery packs. Attractive all-black color scheme. $250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only).FeaturesTrue online, double-conversion UPS provides pure, full-time sine wave AC output free of surges, voltage fluctuations and line noiseq5000VA/3500 watt output power capacity compatible with 200-240V applications at 50/60 Hzq Highlights5000VA / 5kVA / 3500 watt on-line double-conversion 5Urack/tower UPSq200/208/220/230/240V 50/60Hz output, high efficiency economymode optionqHot-swappable battery modules qRS232 & EPO ports; slot fornetwork management cardoptionsqFront panel LEDs with detailedLCD monitoring and controlscreenqExpandable runtime withoptional external battery packs qNEMA L6-30P input (3 wire); L6-30R & L6-20R outputsqPackage IncludesSU5000RT3UPM UPS PowerModuleqBP240V5RT2U External Battery PackqDB9 CableqMounting hardware to supporteach module in 4-postrackmount enclosuresqWarranty informationqInstruction manualqSpecifications3U power module and 2U battery pack installs in any 19 inch rack enclosure using only 5 rack spaces q Double conversion UPS actively converts raw input from AC to DC, then back to perfect sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS typesqProvides perfectly regulated, sine wave output power free of line noise, transient surges and frequency variation for the most efficient operation of critical servers, networking and telecommunications equipmentqAccepts input voltages between 156 and 276, regulating output within 2% of selected 200/208/220/230/240V nominal voltageqSupports connected equipment during blackouts for 20/8 minutes at half/full load levels. Runtime is further expandable with optional external battery packs qIntelligent battery management system extends battery lifeq Network interfaces support simultaneous communications via 2 DB9 ports and slot for network management card optionsqCompatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX,SNMPWEBCARD, MODBUSCARD and RELAYIOCARDqSerial port enables data-saving unattended shutdown when used with Tripp Lite's PowerAlert software,available via FREE download from /products/power-alert qBuilt-in Emergency Power Off (EPO) interface with cable q Includes 4 built-in output receptacles (2 L6-30R, 2 L6-20R)q L6-30P input plug-in connectionq Front panel LEDs and LCD readout with scroll button enables visual confirmation of all major UPS functions and current site electrical conditionsqFront panel switches enable power on/off control, self-test and alarm cancel functionsq Included adjustable mounting rails support installation in 4 post 19 inch rack enclosures. Optional 2POSTRMKITHD supports 2 post rackmount installationqUPS ships fully assembled in full compliance with DOT regulations, no time consuming connection of internal batteries by user is requiredqFault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions q $250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only)q© 2023 Eaton. All Rights Reserved. Eaton is a registered trademark. All other trademarks are the property of their respective owners.。
晓科技 RACM100 医疗级 AC DC 电源设备说明书

DescriptionThe RACM100 is a compact 3” x 2” high efficiency AC/DC power supply with 2xMOPP 3rd Ed. safety approval for medical applications. The range has now been extended to include open frame models (/OF suffix). Like the original enclosed versions, the RACM100/OF series are space-saving universal input voltage power supplies (85-264VAC), with 4kVAC isolation, PFC, no minimum load and can be used at ambient temperatures of between -25°C and +85°C. The 12V, 15V, 24V or 48V output voltages are fully protected and have tolerances of less than ±0.2% over the entire input voltage range and less than ±0.5% over the entire load range. The RACM100/OF series is certified to medical safety standard IEC/ES/EN-60601-1 3rd Edition and feature BF rated outputs with less than 75µA leakage current. It has a built-in Class B EMI filter and comes with a five year warranty.RACM100AC/DC Converter100 Watt Enclosed &Open Frame Case StyleSingle OutputIEC/EN60601 certifiedANSI/AAMI ES60601 certified EN55011 certified CISPR11FCC Part 152MOPP250VACE314885FeaturesRegulated Converter• Long 5 year warranty • 2MOPP/250VAC• Suitable for built in Class II applications • Wide input voltage range (85-264VAC)• Low leakage current (<75µA)• 5000m operation• Active power factor correctionSelection GuidePart Input Output Output Input Power Efficiency Max. Capacitive Number Voltage Range Voltage Current @ No Load typ. Load (1)[VAC] [VDC] [A] [W] [%] [µF]RACM100-12S (1) 85-264 12 8.34 0.3 91 6950RACM100-15S (1) 85-264 15 6.67 0.3 92 4450RACM100-24S (1) 85-264 24 4.17 0.3 92 1750RACM100-48S (1) 85-264 48 2.09 0.391430Case Style (2)S ingleOutput Power Output VoltageModel NumberingRACM100- __ S/ __Notes: Note2: without suffix, standard enclosed caseadd suffix “/OF” for open frame styleNotes:Note1: Max Cap Load is tested at minimum input and full resistive loadExamples:RACM100-12S = 12Vout, standard enclosed case RACM100-24S/OF= 24Vout, open frame styleSpecifications (measured @ Ta= 25°C, 250VAC, full load and after warm-up)Specifications (measured @ Ta= 25°C, 250VAC, full load and after warm-up)REGULATIONSParameter Condition Value Output Accuracy230VAC, full load±1.0% Line Regulation low line to high line, full load±0.2%Load Regulation 0% to 100% load10% to 100% load0.5% max.0.4% max.Transient Peak Deviation load step from 50% - 75% change at 2.5A/µs 3.0% Vout max. Transient Recovery Time load step from 50% - 75% change at 2.5A/µs500µs typ.PROTECTIONSParameter Condition Value Input Fuse internal line and neutral T3.15A / 250VAC, slow blow type Short Circuit Protection (SCP)continuous, auto-recovery Over Load Protection (OLP)% of Iout rated (Hiccup)115% min. / 150% max. Over Voltage Protection (OVP)% of Vout nominal (Latch off)115% min. / 135% max.Isolation Voltage (5)tested for 1 minuteI/P to O/PI/P to CaseO/P to Case4kVAC1.5kVAC1.5kVACIsolation Resistance500VDC100M W min. Insulation Grade reinforced Leakage Current264VAC75µA max. Means of Protection working voltage 250VAC/continuous2MOPP Medical Device Classification built-in power supplyInternalclearancecreepage>8.0mm>8.0mm Notes:Note5: For repeat Hi-Pot testing, reduce the time and/or the test voltageENVIRONMENTALParameter Condition ValueOperating Temperature Rangerefer to ”Derating Graph”-25°C to +85°C full load, 230VACenclosedopen frame-25°C to +60°C-25°C to +55°CTemperature Coefficient±0.02%/K Operating Altitude5000m max. Operating Humidity non-condensing5% to 95% RH Pollution Degree PD2 High Temperature Operating Life (HTLO)JEDEC JESD22-A108 Shock IEC60068-2-27 Vibration IEC60068-2-6 MTBF according to MIL-HDBK-217F, full load, +25°C790.3 x 103 hoursSpecifications (measured @ Ta= 25°C, 250VAC, full load and after warm-up)SAFETY AND CERTIFICATIONSCertificate Type (Safety)Report / File Num ber StandardMedical Electric Equipment, General Requirements for Safety and Essential Performance E314885CAN/CSA-C22.2 No. 60601-1:14 ANSI/AAMI ES60601-1:2005 + A2:2010Medical Electric Equipment, General Requirements for Safety and Essential Performance (CB)181200102IEC60601-1:2005 + A1:2012, 3rd EditionMedical Electric Equipment, General Requirements for Safety and Essential Performance EN60601-1:2006 +12:2014Information Technology Equipment - General Requirements for Safety (LVD)TW1708008-001EN60950-1:2006 + A2:2013Information Technology Equipment - General Requirements for Safety IEC60950-1:2005, 2nd Edition + A2:2013 EAC RU-AT.49.09571TP TC 004/2011 TP TC 004/2011 RoHS2RoHS-2011/65/EU + AM-2015/863EMC Compliance (Medical)Conditions Standard / Criterion Medical electrical equipment - Part 1-2: General requirements for basic safety and essentialperformance - Collateral standard: Electromagnetic compatibility - Requirements and testsEN60601-1-2:2015Industrial, scientific and medical equipment – Radio frequency disturbance characteristics – Limits and methods of measurementEN55011:2009 + A1:2010 Class B Conducted, Class A RadiatedIndustrial, scientific and medical equipment - Radio frequency disturbance characteritics -Limits and methods of measurementCISPR11:2009 + A1:2010 Class B Conducted, Class A RadiatedESD Electrostatic discharge immunity test Air ±15kV; Contact ±8kV IEC61000-4-2:2008 Radiated, radio-frequency, electromagnetic field immunity test10V/m (80-2700MHz)27V/m (385MHz)28V/m (450MHz)IEC61000-4-3:2006 + A2:2010 Fast Transient and Burst Immunity AC Power Port: ±2kV IEC61000-4-4:2012Surge Immunity ACPort:L-N= ±1kVL-GND= ±2kVIEC61000-4-5:2005Immunity to conducted disturbances, induced by radio-frequency fields6Vr.m.s IEC61000-4-6:2013 Power Frequency Magnetic Field50Hz, 30A/m IEC61000-4-8:2009Voltage Dips and Interruptions Dips: >95%; 30%;Interruptions >95%IEC61000-4-11:2004Limits of Harmonic Current Emissions EN61000-3-2:2005 + A2:2009, Class D Limits of Voltage Fluctuations and Flicker EN61000-3-3:2013Specifications (measured @ Ta= 25°C, 250VAC, full load and after warm-up)DIMENSION and PHYSICAL CHARACTERISTICSParameter Type Value Material enclosed aluminumDimension (LxWxH)enclsodedopen frame91.4 x 62.0 x 39.2mm76.2 x 50.8 x 32.0mmWeightenclosedopen frame210g150gEMC Compliance (Industrial)Conditions Standard / Criterion Limitations on the amount of electromagnetic intererence allowed from digital & electronic devices47CFR FCC Part 15 Subpart B, Class B Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical andElectronic Equipment in the Range of 9 kHz to 40 GHzANSI C63.4:2014 Electromagnetic compatibility of multimedia equipment – Emission Requirements EN55032:2015+AC:2013, Class B Information technology equipment - Immunity characteristics - Limits and methods ofmeasurementEN55024:2010+A1:2015 ESD Electrostatic discharge immunity test Air ±8kV; Contact ±6kV IEC61000-4-2:2008, Criteria ARadiated, radio-frequency, electromagnetic field immunity test 3V/m (80-1000MHz)20V/m (80-1000MHz)3V/m (1-2.5GHz)10V/m (1-2.5GHzIEC61000-4-3:2006 + A2:2010, Criteria AFast Transient and Burst Immunity DC Port: ±2kV IEC61000-4-4:2012, Criteria A Surge Immunity DC Port: ±1kV IEC61000-4-5:2014, Criteria A Immunity to conducted disturbances, induced by radio-frequency fields DC Power Port 3V + 20V IEC61000-4-6:2013, Criteria APower Frequency Magnetic Field 50Hz/60Hz 1A/m50Hz/60Hz 10A/mIEC61000-4-8:2009, Criteria AVoltage Dips and Interruptions Dips: >95%; 60%; 30%Interruptions >95%IEC61000-4-11:2004, Criteria AIEC61000-4-11:2004, Criteria BLimits of Harmonic Current Emissions EN61000-3-2:2014, Class D Limits of Voltage Fluctuations and Flicker EN61000-3-3:2013Specifications (measured @ Ta= 25°C, 250VAC, full load and after warm-up)Specifications (measured @ Ta= 25°C, 250VAC, full load and after warm-up)PACKAGING INFORMATIONParameter Type ValuePackaging Dimension (LxWxH) cardboard box enclosed case418.0 x 258.0 x 105.0mm open frame494.0 x 250.0 x 95.0mmPackaging Quantity enclosed case10pcs open frame25pcsStorage Temperature Range-40°C to +85°C Storage Humidity non-condensing5% to 95% RHThe product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause。
南方电网科学研究院有限责任公司_企业报告(业主版)

IPS5000系列变电站综合自动化系统

I PS5000系列变电站综合自动化系统I PS5000-210C双绕组变压器差动保护装置 技术及使用说明书V1.8北京清大华康电子技术有限责任公司二零零七年五月目 录1.概述 (3)2. IPS 5210C主要功能 (4)3.主要技术要求和指标 (4)3.1工作环境条件 (4)3.2周围环境 (4)3.3电源 (4)3.4主要技术参数 (5)4.工作原理 (6)4.1基本原理 (6)4.2比率差动保护 (7)4.3二次谐波闭锁比率差动保护 (7)4.4差动速断 (7)4.5CT断线闭锁 (8)4.6励磁涌流记录 (8)4.7保护逻辑 (8)4.8故障录波 (9)4.9测量通道的软件校正处理 (9)4.10SOE记录 (10)4.11硬件说明 (10)5.定值与参数说明 (13)5.1定值清单 (13)5.2定值说明 (13)5.3通信参数表说明 (15)6.装置结构与接线端子图 (16)6.1结构外形 (16)6.2面板按键与指示灯操作说明 (18)6.3后面板端子接线说明 (19)7.面板显示操作功能说明 (21)7.1屏幕显示操作功能一览表 (21)7.2主屏幕显示 (21)7.3一级菜单 (22)7.4系统信息显示 (22)7.5常规显示 (23)7.6参数查询 (26)7.7参数设置 (29)7.8SOE查询 (32)7.9测量校正 (33)7.10就地操作 (36)7.11其他 (37)1.概述IPS 5000系列变电站综合自动化系统是在MPS4000变电站综合自动化系统(国家863项目)的基础上,发展起来的新一代变电站成套保护装置,它继承了第四代变电站综合自动化系统MPS4000的“精度高”、“响应快”等优点,利用了当前最先进的32位DSP控制芯片作为主CPU完成装置的主要工作,提高了系统的稳定性和可靠性。
5000系列变电站综合自动化系统由如下产品构成:IPSIPS 5100系列线路保护装置IPS 5110 微机线路保护装置IPS 5120微机电容保护装置IPS 5130微机方向线路保护装置IPS 5140微机零序距离线路保护装置IPS 5150微机横差电流方向线路保护装置IPS 5160微机母线差动保护装置IPS 5200系列主设备保护装置IPS 5210 微机双绕组变压器差动保护装置IPS 5220微机三绕组变压器差动保护装置IPS 5230微机变压器后备保护装置IPS 5240微机发电机差动保护装置IPS 5250微机发电机后备保护装置IPS 5260微机电动机差动保护装置IPS 5270微机电动机保护装置IPS 5280微机厂(站)用变保护装置IPS 5300系列测控装置IPS 5310 微机遥测遥控装置IPS 5320 微机遥信遥控装置IPS 5330 微机遥调装置IPS 5340 微机自动准同期装置IPS 5340 微机备自投装置IPS 5360 微机PT切换装置IPS 5370 微机脉冲电度测量装置IPS 5380 微机多功能变送测量装置IPS 5390 微机解列装置IPS 5400系列管理装置单元IPS 5410 通信装置IPS 5420 管理单元IPS 5430 双机管理单元IPS 5000-210B变压器保护单元主要用于35 kV~110kV变电站的双绕组变压器差动保护,其主要特点是:z采用主频高达150MHz的DSP及总线不出芯片技术,精度高、响应快、系统稳定性好;z液晶全中文显示,实时更新,操作简单方便,菜单简洁明了;z10组定值存储功能,方便用户切换和修改;z支持同时采用RS 485和CAN方式进行双路通信,支持多种远动传输规约,方便与各种管理系统连接;z高速故障记录和故障动态过程记录为用户带来低成本、高性能的享受,并实现录波数据掉电不丢失,方便用户随时调用;z集成度高、体积小、重量轻,便于集中和分散安装。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
K E D Y-5000智能一体化电源系统第一章系统简介KEDY-5000系列数字化变电站智能一体化电源系统是借鉴数字化变电站核心思想,采用分层分布架构,全站交流、直流、UPS、通信等电源一体化设计、一体化配置、一体化监控,将站用电源各子系统通信网络化、系统化,实现站用电源信息共享。
监控软件集成到信息一体化平台中,不独立设置一体化电源监控工作站;采用DL/T860(IEC61850)标准建模并接入统一的智能网络平台,上传至远方控制中心,实现变电站电源的集中供电和统一监控管理,实现在线的状态监测,实现“四遥”及无人值守。
一、技术特点◆适合构成110kV及以下各类变电站、电气化铁路、钢铁冶金、煤矿、化工等需要电源的场所;◆打破传统电源专业界限,统一配置,取消UPS蓄电池、通信蓄电池组及充电装置,利于管理;◆对重要负荷如事故照明等采用逆变电源供电;统一进行波形处理;统一进行防雷配置;统一进行二次配电管理,节约占地面积,节约运营成本;◆以直流操作电源为核心,系统共享直流操作电源的蓄电池组,构成一体化电源设备;◆监控器采用7寸(或10寸)彩色触摸屏,界面图形化,显示直观,实现真正意义上的人机对话;◆全模块化设计:系统实现所有开关智能模块化、电源功能单元模块化,组屏简单,配置灵活,使设计、生产、维护标准化;◆全数字化设计:系统无屏内及跨屏二次接线,上行下达信息数字化传输,采用高速以太网接口,实现IEC61850规约通信;◆全组装化设计:全模块化使安装接口标准化,可实现系统快速组装;◆N+1热备,可平滑扩容,满足不同容量系统;◆分散多级监控系统,实现监控系统的简单可靠;◆组件配套齐全,提供全方位的组屏解决方案。
二、型号定义及说明直流额定输出电流(A)直流标称输出电压(V)装置交流额定输出电压(V)额定容量kVA×UPS组数装置充电装置直流额定输出电流(A)×充电装置组数充电装置直流标称输出电压(V)蓄电池组容量(Ah)×蓄电池组数设计序号电力用一体化电源设备设计型号三、使用条件◆用于室内,环境温度不低于-10℃,不高于45℃;◆安装使用地点海拔2000m及以下;◆日平均相对湿度不大于95%,月平均相对湿度不大于90%(环境温度25℃);◆装置的使用地点应无爆炸危险、无腐蚀性气体及导电尘埃、无腐蚀金属和破坏绝缘的气体,无强电磁场干扰;◆无强烈振动和冲击,垂直倾斜度不超过8°;◆如在不符合上述条件的特殊设环境中使用,用户应在订货时提出,以保证产品能够可靠地工作。
第二章智能一体化电源组成方案采用一体化设计思路,对站用电源进行全面整合:将智能一体化监控、交流电源系统、直流电源系统、通信电源系统、UPS系统统一设计、监控、生产、调试、服务;通过一体化监控模块将站用电源各子系统通信网络化,实现站用电源信息共享,建立数字化电源软件平台;一体化监控模块通过以太网接口、IEC61850规约与上位机系统通信,使站用电源系统成为开放式系统。
交流分系统额定输出电压为AC380/220V;直流分系统额定输出电压为DC220V(DC110V);逆变电源分系统额定输出电压为AC220V;通信电源系统额定输出电压为48V。
不同的接线方式由不同的输出馈电,但基本原理一至,原理框图如下图所示:系统基本组成方框图各组件基本功能如下:一、智能一体化监控功能1、人机界面功能:监控主界面采用图形化显示,直观显示系统结构以及主要监测数据。
直观显示交流系统、直流系统、UPS系统、DC/DC系统数据,触摸对应模块进入详细信息查看页面。
右侧设置有系统快捷菜单,点击可进入相应界面。
2、报警功能:可以对系统检测的任何参量做报警处理,并及时反应系统的报警信息:警报部件名称、报警内容、报警时间。
3、历史记录功能:变化数据自动存储,可显示历史警报记录:报警部件名称、报警内容、报警时间、结束时间。
4、运行记录功能:可显示交流系统、直流系统、DC/DC系统、UPS系统、蓄电池组、绝缘状态的工作情况。
5、逻辑处理功能:如直流绝缘告警,当只有支路漏电流过限报警,而母线绝缘电阻无告警,可自动进行逻辑判断为支路漏电流过限为误报警。
6、程序化联动控制功能:将任务进行编程并固化在一体化监控模块中,一旦程序被激活即可进行相应程序化联动控制。
7、系统联动:根据交流进线运行方式,自动调整直流运行,达到最佳方式运行。
8、二次配电管理:对二次配电进行统一管理,如照明、风机、空调、水泵、门禁等站用非主控设备进行统一智能化管理。
二、交流分系统1、闭锁功能采用ATS自动转换开关,带机械电气双闭锁功能,同时一体化电源智能控制模块还带有电气闭锁,确保任何情况下,两路电源不至于碰撞。
2、正常运行方式方式1:#1进线电源为主供电源,#2进线电源为热备用电源。
方式2:#2进线电源为主供电源,#1进线电源为热备用电源。
3、安全自投功能保证主供电源无电压,且热备用电源电压正常时才能投入热备用电源。
自动投入装置延时动作(延时时间可整定,整定范围:0.5~30秒),并且自动动作一次。
当交流工作母线故障时或手动断开工作电源时自动投入装置均不动作。
主供电源恢复供电后,发预告信号。
自动投入装置动作后发预告信号。
4、自恢复功能:主供电源消失后又恢复,系统自动恢复主供电源供电。
5、检修状态功能:可通过ATS选择开关,将开关置于“手动”位,方便检修人员对控制部分进行维修。
6、通讯功能:综自系统可在后台更改运行模式、查看电气参数、查看事件记录等。
7、遥控功能:对ATS自动转换开关具有遥控功能,可在远方变更当前运行模式。
8、监控功能1)状态监视监测ATS开关位置状态,自投装置动作、装置故障告警、母线电压异常告警、站用电源消失告警、馈线开关报警等。
2)电气量远方监测与显示一体化监控模块可显示三相交流电压、电流、功率、功率因数,交流总功率、总电能,以及交流1路频率和交流2路频率。
3)事件记录:告警事件记录、装置动作事件记录信号。
三、直流分系统1、直流监控模块能根据蓄电池充电曲线控制充电模块输出,进行均充、浮充自动转换,定期均充电。
具备放电功能。
能根据设定产生过压、过流、低压等告警信号对蓄电池的过充电、过放电自动保护。
自动巡检、故障自动显示、报警。
交流断电时自动控制向母线供电,确保继电保护、自动装置、高压开关均有控制和操作电源;来电时自动控制投入充电,具备与一体化监控器连接的通信接口。
2、充电模块充电模块交流进线回路配置可靠的C级防雷装置(安装在电源侧)。
充电模块交流进线回路配置高度的电气绝缘防护措施,确保系统和人身安全。
模块内置短路回缩保护,即使模块输出长期处于短路状态也不致损坏;并联保护电路,绝对保证故障模块自动退出系统,而不影响其它模块正常工作;具有完善的保护及告警功能,包括输入过/欠压、输出过/欠压、过温、过流等;自冷方式,工作时可闻噪声不高于30db。
采用LED显示,可查询模块的电压、电流、地址及故障信息。
3、直流母线绝缘监测模块对母线和馈出之路的对地绝缘情况进行监测,产生告警信号,上报数据到监控模块系统,在监控模块中显示正、负极母线对地的电压值和绝缘电阻值。
4、电池监测模块电池监测模块能在线测量单体电池的工作状态,判断性能是否正常;发现有性能异常的电池发出告警,并提供故障电池的准确位置。
5、降压装置系统提供动力馈出和控制馈出两种电压输出。
正常工作时,充电模块对系统的均/浮充电压通常会高于控制母线允许的波动电压范围,所以采用多级硅链调压装置串联在合闸母线与控制母线之间,使调压装置的输出电压满足控制母线的要求。
四、通信电源系统使用DC/DC变换器直接挂于直流母线,电压稳定,抗干扰能力强。
具有过电压、欠电压、过电流、短路、过温保护和自动限流等功能。
五、UPS系统电力用交流不间断电源(UPS)直接挂于直流母线,正常运行时由交流输入供应负载电源,一旦交流输入消失,无延时切换到直流输入供电,保证监控计算机、重要负荷不受影响。
第三章智能一体化电源系统设计方案在实际设计中,可根据不同的接线方式以达到要求,可用以下提供的九种接线方案实行组屏:1、单电池组单母线分段:无降压装置GZDW30、有降压装置GZDW32、有降压装置GZDW34(控制母线自带模块输出)2、单电池组单母线不分段:无降压装置GZDW31、有降压装置GZDW33、有降压装置GZDW35(控制母线自带模块输出)3、双电池组双组充电模块双母线:无降压装置GZDW40、有降压装置GZDW41、有降压装置GZDW42(控制母线自带模块输出)单电池单母线不分段第四章模块及技术指标主要性能指标◆交流输入电压: 323~456V◆交流输入频率: 49~51Hz◆交流输入电压不对称度:≤5%◆功率因数: >0.93◆输入2-19次各次谐波电流含有率: <30%◆直流额定电压: 25V、50V、115V、230V◆直流标称电压(Un): 24V、48V、110V、220V◆充电电压调整范围:(90%~125%)Un◆直流控制母线电压范围:(85%~112.5%) Un◆直流动力母线电压范围:(87.5%~117.5%) Un◆稳流精度:不大于±1%(在20%~100% 输出额定电流时)◆稳压精度:不大于±0.5%(在0%~100% 输出额定电流时)◆均流不平衡度:≤3%◆纹波系数:≤0.2%◆效率: >95%◆设备负载等级:一级,即连续输出额定容量◆噪声:≤30dB(距装置1m处)◆冷却方式:采用自然冷却或强迫风冷◆对时接口: IRIG-B(DC)码、PPS(秒脉冲)、PPM(分脉对时)◆通讯接口: RS485/RS232通讯接口及以太网通讯接口◆通讯规约: Modbus、IEC61850规约一、一体化监控监控主界面采用图形化显示,直观显示系统结构以及主要监测数据。
1、主界面直观显示交流系统、直流系统、UPS系统、DC/DC系统数据,触摸对应模块进入详细信息查看页面。
底部设置有系统快捷菜单,点击可进入相应界面。
2 、信息查询点击标签页可切换显示各种详细信息,点击关闭按钮退出详细信息界面。
★直流屏数据显示直流数据包括:整流模块输出电压、输出电流、状态,控母电压、负载电流、合母电压。
★电池数据显示电池组温度、电池组电流、电池组电压和单节电池电压。
★绝缘数据可显示母线绝缘数据:正对地电压、负对地电压、正对地电阻、负对地电阻和支路绝缘状态。
★开关量数据可显示各开关量的自定义名称、显示方式、接入方式、开关量状态。
★交流屏数据显示三相交流电压、电流、功率、功率因数,交流总功率、总电能,以及交流1路频率和交流2路频率。
★UPS电源数据显示UPS电源的交流输入电压、交流输入频率;直流输入电压、输出电压、输出频率、输出电流。