暖通毕业设计论文
毕业设计说明书题目:上海市某宾馆中央空调系统设计(四层夜总会)所属系、部:建筑工程学院年级、专业:建筑设备工程技术 101姓名: x x x学号: 2010 0809 xxxx指导教师: x x x 老师完成时间: 2013年5月摘要本工程为上海市某宾馆中央空调系统设计,该建筑是包含办公室、大堂、客房、夜总会、餐厅等于一身的多功能建筑。
根据各层建筑的构造及功能,办公楼部分和客房部分选用风机盘管加新风系统,夜总会部分、大堂部分和餐厅部分选用全空气系统。
设计内容:1、空调冷负荷计算2、系统方案确定3、冷源选择4、辅助设备选型5、空调末端处理设备的选型6、风系统设计与计算7、水系统设计,布置及计算技术参数:1、上海市的气象参数2、设计参数设计依据:1、技术参数2、相关设计规范手册关键词:负荷计算;方案选定;设备选型;全空气系统;风系统;水系统;AbstractThis works for a Shanghai hotel central air conditioning system design, the building is office, lobby, guest rooms, nightclubs, restaurants as a multifunctional building.According to each layer architecture and function in the construction of the building parts, lobby and guest room part selects fan-coil unit plus fresh air system, nightclubs and restaurants part selects the all-air system.Design content: 1, the air condition cold load calculation 2, the scheme in the system 3, choice of cold source 4, auxiliary equipment selection 5, air terminal handling equipment selection 6, the wind system design and calculation 7, water system design, layout and calculationtechnical parameters: 1, the Shanghai meteorological parameters 2, the design parametersDesign basis: 1, the technical parameters 2, the related design specifications manualKey words: load calculation; Scheme is selected; Equipment selection; All air system; The wind system; Water system;目录1.建筑概况 (1)2.设计依据 (1)2.1 设计主题 (1)2.2 设计任务 (1)2.3 设计要求 (1)2.3.1 设计原则 (1)2.3.2 图纸要求 (2)2.4 设计资料 (2)2.4.1 土建条件 (2)2.5 室外气象参数 (3)2.6 夏季室内设计参数 (3)3.负荷计算 (4)3.1 围护结构冷负荷计算 (4)3.1.1 外墙传热冷负荷 (4)3.1.2 外窗冷负荷 (6)3.2 人体冷负荷计算 (7)3.3 照明冷负荷计算 (9)3.4 新风冷负荷计算 (11)3.5 湿负荷计算 (12)3.5.1 人体湿负荷 (12)3.5.2 新风湿负荷 (13)3.6第四层夜总会精算负荷计算表 (13)3.7 其余楼层概算负荷表 (14)4.风系统方案比选 (15)4.1 风系统分类对比 (15)4.1.1 全空气系统 (15)4.1.2 空气-水系统 (15)4.2 风系统方案确定 (16)4.3 风系统方案设计计算 (17)4.3.1 一次回风空调系统 (17)4.3.2 夏季风量和冷量的计算 (17)4.4 组合式空调机组选型 (19)4.5 风管阻力计算 (19)5.空调冷热源选型 (24)5.1 冷热源分类 (24)5.1.1 活塞式水冷冷水机组 (24)5.1.2 螺杆式水冷冷水机组 (25)5.1.3 离心式冷水机组 (25)5.2 冷热源的确定 (26)5.2.1 冷热负荷的计算 (26)5.2.2 影响冷热源选择的因素 (26)5.3 冷却塔选型 (28)5.3.1影响冷却塔选择的因素 (28)5.3.2选定冷却塔 (28)5.4 水泵选型 (29)5.4.1 冷冻水泵 (29)5.4.2 冷却水泵 (31)6.致谢 (33)7.参考文献 (34)1.建筑概况本工程为上海市某商用中央空调系统设计。
整栋建筑地下一层(层高4.7m),地上21层,其中一层为大堂,二、三层为餐厅,四层为夜总会,五—七层为办公楼,八层为设备层(不予考虑),9-21层为客房(层高 3.4m,窗下墙1.0m,窗1.7m,窗上墙0.7m)。
(其余1-2层层高4.8m,窗下墙0.3m,窗4.3m,窗上墙0.5m;3-7层层高4.8m,窗下墙0.9m,窗2.1m,窗上墙1.8m.)该建筑地下室总建筑面积为1067.5㎡,地上总建筑面积为20711m²。
总空调面积为13938.4m²,任务层即第四层夜总会建筑总面积为1369㎡,空调总面积为951.6㎡。
该空调项目夏季总冷负荷为2443.1KW,冷负荷指标为175.3W/ m²。
夏季任务层精算冷负荷为157.0KW,精算冷负荷指标为165.0W/ m²。
2.设计依据2.1 设计主题上海市某宾馆中央空调系统设计2.2 设计任务四层夜总会空调设计包含冷负荷计算、空调方案选定、设备选型等2.3 设计要求2.3.1 设计原则本设计属于商用中央空调设计,对空调区域没有特殊要求,按照参考文献【1】,参考文献【2】的要求进行设计;防火将会按照参考文献【7】的要求进行设计。
2.3.2 图纸要求①主机房(冷冻机房)平面图;(A1)②整栋楼空调水系统原理图;(整栋大楼,包括主机系统和末端系统,可分开画)③任务所在层送回风管平面图(A2,全空气系统选择)④空调机房平剖面图;要求图纸能较好表达设计意图,符合制图标准和相关规范,主要图纸基本达到施工图深度,图纸总张数不少于4张,计算机绘图。
2.4 设计资料2.4.1 土建条件一、外墙内表面水泥沙浆20厚,200厚加气混凝土,外表面瓷砖贴面20厚二、内墙150厚加气混凝土墙体,内表面为20厚水泥沙浆找平,面层涂多彩涂料三、窗铝合金窗框,单层5mm普通玻璃,内挂浅蓝色窗帘四、楼板1.客房15厚1:2白水泥、石子水磨面层,地面上铺地毯。
20厚1:23水泥沙浆找平,100厚钢筋混凝土楼板2.办公及裙房大理石面层,15厚水泥沙浆找平,100厚钢筋混凝土楼板五、屋顶40厚细石混凝土,三毡四油,冷底子油,20厚水泥沙浆,120厚沥青膨胀珍珠岩,一毡二油隔气层,冷底子油一道,20厚水泥沙浆找平,100厚钢筋混凝土屋面六、种植屋面200厚种植土(30%锯木,70%泥土),40厚细石混凝土,三毡四油,160厚沥青膨胀珍珠岩,一毡二油隔气层,20厚水泥沙浆找平,100厚钢筋混凝土屋面七、门大门、侧门和公共部分内门均为铝合金,楼梯间、前室为木质防火门,其余为木门,尺寸详图2.4.2 水源条件以市政自来水管网为设计大楼的设计水源。
2.5 室外气象参数根据参考文献【1】查得上海市室外气象参数,如下表2-1:2.6 夏季室内设计参数根据参考文献【1】,参考文献【6】查取室内设计参数,如下表2-2:表2-2 四层夜总会夏季室内设计参数3.负荷计算3.1 围护结构冷负荷计算3.1.1 外墙传热冷负荷在日射和室外气温综合作用下,外墙和屋面的逐时冷负荷可按以下公式计算:Qc(て)=AK(tc(て)-tR) (式3-1) 式中 Qc(て)_____外墙或屋面的逐时冷负荷,W;A_____外墙或屋面的面积,㎡;K_____外墙或屋面的传热系数,W/(㎡*℃),可根据外墙和屋面的不同构造,查取系数;tR_____室内计算温度,℃;tc(て)_____外墙或屋面的逐时冷负荷计算温度,℃,其计算方法多样,计算过程也比较复杂,常用已有的计算结果,列表查取。
(1)因资料中给出的各维护结构的冷负荷温度值都是以北京地区气象参数为依据计算出来的。
因此,对于不同地区,应对tc(て)值修正为tc(て)+△td。
其地点修正值△td可由参考文献【11】查得。
(2)当外表面放热系数不等于18.6W/(㎡*℃)时,应将(tc(て)+△td)乘以表3-1中的修正值。
A0W/(m2*℃)[kcal/(h*m2*℃)]14.2(12)16.3(14)18.6(16)20.9(18)23.3(20)25.6(22)Kα 1.06 1.03 1.0 0.98 0.97 0.95(3)考虑到城市大气污染中和、浅色的耐久性差,建议吸收系数一律采用ρ=0.90,即对tc(て)不加修正。
但可经久保持建筑维护结构表面的中,浅色时,则tc(て)乘以表3-2所列的吸收系数修正值Kρ。
颜色外墙屋面浅色0.94 0.88中色0.97 0.94综上所述,外墙和屋面的冷负荷计算温度为:t1c(て)=(tc(て)+△td)Kα*Kρ则冷负荷计算式应改为Qc(て)=AK(tc(て)+△td)Kα*Kρ-tR) (式3-2)以北外墙为例,经计算北外墙面积为164.1㎡,由表3-1,3-2查出Kα,Kρ值,地点修正值△td,传热系数K,逐时冷负荷计算温度tc(て)均由参考文献【11】查得,室内计算温度tR已知,即可按式3-2算出相应的逐时冷负荷。
计算结果如表3-3。
北外墙逐时冷负荷 Qc(て)=AK(tc(て)+△td)Kα*Kρ-tR)时间18:00 19:00 20:00 21:00 22:00 23:00 0:00 1:00 2:00 3:00 4:00 5:00 6:00 tc(て)31.6 31.8 32.1 32.4 32.6 32.9 33.1 33.2 33.2 33.2 33.1 33 32.8 △td 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 Kα0.97 0.97 0.97 0.97 0.97 0.97 0.97 0.97 0.97 0.97 0.97 0.97 0.97 Kρ0.97 0.97 0.97 0.97 0.97 0.97 0.97 0.97 0.97 0.97 0.97 0.97 0.97 tR26 26 26 26 26 26 26 26 26 26 26 26 26 k 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.93.1.2 外窗冷负荷(1)外窗逐时传热形成的冷负荷在室内外温差作用下,通过外玻璃窗传热形成的冷负荷可按以下公式计算: Qc(て)=KwAw(tc(て)-tR) (式3-3)式中 Qc(て)_____外玻璃窗的逐时冷负荷,W;Kw_____外玻璃窗的传热系数,W/(㎡*℃);Aw_____窗口面积,㎡;tc(て)_____外玻璃窗的冷负荷温度的逐时值,℃。
暖通空调 毕业论文
暖通空调毕业论文暖通空调在现代建筑中扮演着重要角色,在提高室内环境质量和节能方面起着重要作用。
本文将从暖通空调的基本原理、节能技术以及现代温控系统等方面进行论述。
一、暖通空调的基本原理暖通空调主要是通过控制室内温度、湿度和空气品质来满足人们对室内环境的需求,其主要包括供暖系统、通风系统和空调系统三部分。
供暖系统主要包括采暖和热水供应两个方面,采用不同的热源、燃料和供热方式可以实现多种供暖方式,如热水辐射、空气加热、地暖等。
通风系统主要通过机械通风和自然通风两种方式来实现,机械通风采用送、排风机实现空气的循环和新鲜空气的补给,而自然通风则利用自然气流或温差实现空气流通和换气。
空调系统主要包括制冷、制热和空气调节等方面,其工作原理是通过制冷剂的循环流动来实现空调制冷,而制热则是依靠热泵或电热器等方式来实现。
空气调节包括控制室内空气湿度、质量和流量等方面。
二、暖通空调的节能技术暖通空调在实现舒适、健康的室内环境的同时,也消耗了大量的能源。
因此,节能技术的应用是提高暖通空调系统能效和降低能源消耗的关键。
1. 高效供暖采用高效、低耗的燃料和热源,如地源热泵、太阳能、燃气锅炉等。
2. 通风换气采用新型的通风换气方式,如温度和湿度控制、CO2浓度控制、热回收等技术,以降低能源消耗和排放。
3. 区域控制根据不同区域的不同需求,采用独立控制系统,实现室内温度、湿度和空气品质等的差异化调节,以提高能效。
4. 节能材料和技术采用节能建材和设计,如高效节能窗户、隔热墙体、优化日光利用等,以减少能量损失和提高系统效率。
三、现代温控系统的应用现代温控系统是暖通空调中的关键技术之一,其通过监测室内温度、湿度和空气品质等参数,自动调节供暖、通风和空调系统的运行,以实现目标温度、湿度和空气品质。
目前,市场上存在多种类型的温控系统,如传统的人工调节系统、数字智能温控系统和无人值守智能温控系统等。
数字智能温控系统在智能化程度方面更高,能够实现多种控制模式,并通过数据采集和处理来分析室内环境的变化趋势,优化供暖、通风和空调系统的运行,提高能效。
学生宿舍暖通毕业设计论文_secret
1供暖概述1.1供热工程的发展在人类利用能源的历史上,先后经历了四次重大的突破,即火的使用、蒸汽机的发明、电能的应用以及原子能的利用,这也使供热工程技术的发展划分为四个阶段。
在人类很长的历史时期中,如北京原始人化石发源地龙骨山以及欧洲尼安得塔尔人化石发源地都曾发现过烧火的遗迹,人们以火的形式利用能源。
后来人们为了取得热量,开始用原始的炉灶获得热能以取暖、做饭和照明。
这种局部的取暖装置至今还保留和使用着,如火炉、火墙、火坑等。
蒸汽机的发明,促进了锅炉制造业的发展。
十九世纪初期开始出现了以蒸汽或热水作为热媒的供暖系统。
在供暖系统中,由一个锅炉产生的蒸汽或热水,通过管路供给一座建筑物各房间取暖。
1877年在美国建成了区域供热系统,由一个锅炉房供给全区许多座建筑物和生产与生活所用的热能。
二十世纪初期一些工业发达的国家开始利用发电厂中汽轮机的废汽,供给生活与生产用热。
其后逐渐发展为现代化的热电厂,联合生产电能与热能,显著地提高了燃料利用率。
二次大战后,特别是六十年代,世界能源的消耗,随着城市工业的发展和城市人口的增加而迅速地增加,1950~1965年间,联邦德国、捷克斯洛伐克等国热能消耗量增长了2倍,日本增长了3.7倍。
巨大的热能消耗,不仅要求有足够的供应能力,而且要求提高供热效率和降低成本。
此外,锅炉房多建于城市人口稠密区,煤烟粉尘和锅炉排出的二氧化硫气体是造成城市环境污染的主要原因。
在区域供热系统中采用大型现代化锅炉,燃烧效率高,尤其是综合生产热能与电能的热电厂可以大量节省能源、大型区域供热系统供热半径长、热源可以远离城市中心人口稠密区,并可装设有效的排烟除硫和除尘设备以防止城市环境的污染。
因此,近30年来区域供热事业的发展极为迅速。
苏联和东欧各国的区域供热的热源以热电厂为主。
美国和西欧各国的区域供热的热源,多以区域锅炉房为主,早期以蒸汽作为主要热媒,二次世界大战以后,以高温水为热媒的区域供热系统发展很快。
暖通工程设计方案分析论文
暖通工程设计方案分析论文一、前言暖通工程是指建筑室内环境设计中的供暖、通风、空调及采暖设备等工程。
暖通工程在建筑设计中占据着十分重要的位置,其设计方案的科学合理与否,直接影响到建筑内部环境的舒适性、节能性能以及使用寿命等方面。
本文将对暖通工程设计方案进行分析,探讨其设计原则、技术方案、性能要求和应用效果等方面的内容。
二、设计原则1. 舒适性原则:暖通工程设计的首要目标是要保证建筑内部环境的舒适性,即在各种气候条件下,都能够满足人们对室内温度、湿度、空气质量等方面的需求。
2. 节能性原则:在满足舒适性要求的前提下,设计方案应当注意节能,优先采用高效节能设备、合理利用太阳能和地热能等可再生能源,以减少能源消耗和环境污染。
3. 安全性原则:在设计暖通工程方案时,首先要确保其安全性。
采暖设备应当符合国家相关标准,能够稳定可靠地运行,避免发生安全事故。
4. 可维护性原则:设计方案应该考虑设备的维护便捷性,通过合理的布局和设备选型等措施,降低设备运行时的维护成本和维修难度。
三、技术方案1. 供暖系统:采暖系统是暖通工程的重要组成部分,在选择供暖方式时,应根据建筑的用途、规模、气候条件等因素综合考虑。
传统的供暖方式包括集中供暖和分户供暖等,而随着能源技术的发展,地源热泵、空气源热泵等可再生能源供暖方式也逐渐得到应用。
2. 通风系统:通风系统是保持室内空气清新的重要手段,其设计应当满足室内空气的充分换气和质量的补给。
常见的通风方式包括自然通风、机械通风和混合通风,其中机械通风通常能够更好地适应室内环境变化和外部环境条件的变化。
3. 空调系统:空调系统在炎热的夏季和寒冷的冬季能够有效地调节室内温湿度,提高室内环境的舒适性。
目前,中央空调、分体空调和VRF空调等多种空调技术被广泛应用,各有其特点和适用场合。
4. 采暖设备:采暖设备是供暖系统的核心部分,包括锅炉、暖气片、地暖等。
在选择采暖设备时,应当综合考虑设备的能效比、运行成本、维护便捷性等因素,选择适合建筑需求的设备。
暖通空调毕设论文正文
暖通空调毕设论文正文1. 引言本文旨在研究暖通空调系统在建筑中的应用和优化措施。
暖通空调作为建筑中不可或缺的一局部,对室内温度和空气质量的控制起着重要的作用。
本文将从系统原理、设计计算、设备选型和优化措施等方面进行深入研究。
2. 系统原理暖通空调系统是建筑中对室内温度、湿度和空气质量进行调控的系统。
系统主要包括供热系统、供冷系统、通风系统和空气处理系统。
在本章中,将对这几个系统的原理进行介绍,包括各个子系统的工作原理和相互之间的关系。
3. 设计计算在设计暖通空调系统时,需要进行一系列的计算,以确定合理的设计参数。
本章将介绍暖通空调系统的设计计算方法,包括热负荷计算、风量计算和管道设计等。
通过合理的计算方法,可以有效地确定系统的尺寸和配套设备,从而提高系统的效能和能源利用率。
4. 设备选型在暖通空调系统中,设备选型是决定系统性能的关键因素之一。
本章将介绍常见的暖通空调设备,包括供热设备、供冷设备、风机和空气处理设备等。
对每种设备的特点和选型规那么进行详细介绍,帮助读者在实际工程中选择适合的设备。
5. 优化措施为了提高暖通空调系统的效能和能源利用率,可以采取一系列的优化措施。
本章将介绍常见的优化措施,包括系统控制策略、能源管理和新技术应用等。
这些措施可以使系统更加智能化和高效化,提供更舒适和节能的室内环境。
6. 实例分析通过实例分析,本章将对暖通空调系统的应用进行具体说明。
选取几个不同类型的建筑,包括住宅、商业办公和公共建筑等,对其暖通空调系统进行分析和评估。
通过实例分析,可以更好地理解系统设计和优化的实际应用。
7. 结论在本章中,对本文的研究内容进行总结和归纳。
通过对暖通空调系统的深入研究和实例分析,本文提出了一系列的设计和优化措施,以提高系统的效能和能源利用率。
同时也指出了一些需要进一步研究的问题,为后续的工作提供了一定的参考。
参考文献[1] 许XX. 暖通空调系统设计与分析[J]. 建筑技术开发,2024,45(2):15-20.[2] 张XX,王XX. 暖通空调节能技术研究[J]. 建筑节能,2024,36(4):55-60.[3] 李XX,赵XX. 暖通空调系统优化研究综述[J]. 建筑科学与工程,2024,57(6):10-15.以上是?暖通空调毕设论文正文?的大致框架,每个章节可以根据实际情况展开论述。
暖通毕业设计论文
哈尔滨汇来旅馆供暖系统设计摘要本设计是哈尔滨汇来旅馆供暖系统设计。
通过采暖系统的供热使冬季室内温度达到要求,本设计室内温度采取18℃,走廊设计温度为16℃。
设计基本步骤:首先;确定设计基本数据,编写开题报告,绘制建筑草图,并进行采暖热负荷计算。
其次;根据热负荷和建筑物的形式选择供暖系统设计方案,确定采用机械循环同程式单管热水供热系统,会出顶层、标准层和底层采暖平面图,然后进行各层供回水温度计算,确定各房间的暖气片数,并进行了布置。
再次;绘制管路系统图,并标号,进行水力计算,将设计出的各管段管径标注在管理系统图中。
本设计的总立管设于建筑物中部的126室,至顶部分为两个环路,坡度0.003,每个回路最高处装有立式集气罐,回水管位于地下0.5m处。
在引入口处外网的供回水压差为30KPa。
本设计热媒采用热水供暖95℃供水及70℃回水温度。
暖气片采用四柱813型,明装。
室内供暖管道明装,支管与散热器的连接方式为同侧连接,上进下出,不考虑管道向室内散热。
通过本次设计使室内温度得到了改善,达到了设计要求,并且采用热水供暖比蒸汽供暖卫生条件好,耗能低,经济效益好。
关键词供暖;热负荷;散热器;水力计算The Indoor Heat-supply System Design of HarbinHui Lai HotelAbstractThis design is to Harbin to collect hotel heating system design. By heating system of heating in winter indoor temperature meet the requirements, the design indoor temperature 18 ℃, corridor design temperature is 16 ℃.The design basic steps:In the first place. Determine the design basic data, write the opening report, drawing, drawing and heating of the heat load calculation.Secondly; Choose according to heat load and the structure of the form of heating system design scheme, the determination by mechanical cycle with single pipe hot water heating system, will be in the top layer, standard layer and ground floor heating floor plan, then each layer for the return water temperature calculation, determine the room number of the radiator, and has carried on the arrangement.Once again. Map pipeline system, and label for hydraulic calculation, the design of each section diameter annotation in the management system diagram.The design of total stand pipe in the building, room 126, in central to the top is divided into two loops, grade 0.003, each circuit of the top tank is equipped with vertical set, return pipe is located at 0.5 m on underground. For back pressure difference at the entrance to guide the network to 30 kpa.This design heat medium using hot water heating water supplies to 95 ℃and 70 ℃the return water temperature.Radiator appling four-post type 813, Ming. Indoor heating pipe surface mounted, branch pipe and the connecting way of the radiator for ipsilateral connection, top down out, regardless of the pipeline to the indoor heat dissipation.Through the design to make indoor temperature is improved, has reached the design requirements, and adopts the hot water heating steam heating health condition is good, low energy consumption and better economic benefit.Keywords Heating; Heat load; The radiator; Hydraulic calculation目录摘要 (I)Abstract (II)第1章绪论 (1)1.1背景 (1)1.2设计内容................................................................................................ - 2 -1.3我国供热事业的发展概况.................................................................... - 2 -第2章数据资料............................................................................................. - 4 -2.1工程概况................................................................................................ - 4 -2.2设计参数................................................................................................ - 4 -2.3本章小结................................................................................................ - 5 -第3章建筑物供暖系统热负荷的计算...................................................... - 6 -3.1供暖系统设计热负荷............................................................................ - 6 -3.2基本耗热量............................................................................................ - 7 -3.3围护结构传热耗热量............................................................................ - 7 -3.4冷风渗透耗热量.................................................................................... - 9 -3.5冷风侵入耗热量.................................................................................... - 9 -3.6热负荷计算实例.................................................................................. - 10 -3.6.1计算资料....................................................................................... - 11 -3.6.2 121客房供暖设计热负荷............................................................ - 12 -3.7本章小结.............................................................................................. - 12 -第4章采暖方案选择................................................................................. - 16 -4.1热媒的选择........................................................................................ - 16 -4.2 热水热媒和蒸汽热媒的比较............................................................ - 16 -4.3选择热水热媒...................................................................................... - 16 -4.4热水供暖系统的选择.......................................................................... - 16 -4.4.1机械循环热水供暖系统与重力循环热水供暖系统的区别....... - 17 -4.4.2单管系统与双管系统的区别....................................................... - 17 -4.4.3异程式系统与同程式系统区别................................................... - 17 -4.5本章小结.............................................................................................. - 18 -第5章室内热水供暖系统的管路布置和敷设要求................................... - 19 -5.1本系统管路的布置.............................................................................. - 19 -5.2设计注意事项...................................................................................... - 20 -5.3该建筑采暖供热系统的布置.............................................................. - 21 -5.4本章小结.............................................................................................. - 21 -第6章散热器的选型和计算..................................................................... - 22 -6.1散热器要求.......................................................................................... - 22 -6.2散热器的选择...................................................................................... - 22 -6.3散热器的布置...................................................................................... - 22 -6.4散热器的计算...................................................................................... - 23 -6.4.1供回水温计算............................................................................... - 23 -6.4.2散热面积的计算........................................................................... - 24 -6.4.3计算实例....................................................................................... - 24 -6.5本章小结.............................................................................................. - 25 -第7章室内热水供暖系统的水力计算....................................................... - 31 -7.1室内热水供暖系统水力计算的任务和方法...................................... - 31 -7.2等温降法水力计算.............................................................................. - 31 -7.3压力损失最大不平衡率控制.............................................................. - 32 -7.4等温降法水力计算实例...................................................................... - 32 -7.4本章小结.............................................................................................. - 51 -结论............................................................................................................... - 52 -致谢............................................................................................................... - 53 -参考文献....................................................................................................... - 54 -附录A 英语原文 .......................................................................................... - 55 -附录B 中文翻译 .......................................................................................... - 67 -第1章绪论1.1背景哈尔滨的冬季极为寒冷,人们需要一个舒适的室内环境生活和生产。
暖通空调论文
暖通空调论文
暖通空调是一种用于调节室内温度、湿度和空气质量的系统,它在现代建筑中起着重要的作用。
暖通空调系统可以提供舒适的室内环境,同时减少能源消耗和环境影响。
在本论文中,将探讨暖通空调系统的设计、运行和优化。
首先,本论文将介绍暖通空调系统的基本原理和组成部分。
暖通空调系统通常由供暖、通风和空调三个部分组成。
供暖部分负责提供室内热量,通风部分负责循环和净化室内空气,而空调部分负责控制室内温度和湿度。
然后,本论文将讨论暖通空调系统的设计原则和方法。
暖通空调系统的设计应考虑室内外温度差、房间容积、建筑材料和使用需求等因素。
通过合理布局和选用合适的设备,可以实现能源高效和舒适的室内环境。
接下来,本论文将探讨暖通空调系统的运行和管理。
通过监控和调节设备运行参数,可以实现节能和环保的运营。
此外,定期维护和清洁设备也是确保系统正常运行和延长使用寿命的重要措施。
最后,本论文将介绍暖通空调系统的优化方法和未来发展趋势。
通过采用先进的控制策略和技术,如智能控制系统和可再生能源利用,可以进一步提高暖通空调系统的能效和环境影响。
综上所述,暖通空调系统是一种重要的建筑设施,它可以提供
舒适的室内环境,并减少能源消耗和环境影响。
通过合理的设计、运行和优化,可以实现暖通空调系统的高效和可持续发展。
暖通空调毕业设计论文
暖通空调毕业设计论文暖通空调设计论文摘要:暖通空调系统在现代建筑中起着重要的作用。
本文介绍了暖通空调系统的设计原理和应用技术,并针对其中一建筑进行了暖通空调系统的设计。
通过系统的分析和计算,得出了合理的设计方案,并对系统的运行效果进行了评估。
关键词:暖通空调系统、设计原理、应用技术、设计方案、运行效果一、引言暖通空调系统是指以人为中心,为了改善人们在室内的热环境、湿环境和空气质量而进行的技术措施和工程设备的系统。
暖通空调系统在现代建筑中应用广泛,不仅可以提供舒适的室内环境,还可以实现节能减排的目标。
因此,对暖通空调系统进行科学的设计是十分重要的。
二、暖通空调系统的设计原理(一)热负荷计算热负荷计算是暖通空调系统设计的基础,主要包括计算室内热传递热负荷、室外热传递热负荷和风量热负荷。
根据建筑的建筑面积、墙体、窗户、楼顶、地面、人员活动和设备等因素,利用热传递计算公式和热负荷计算软件,得出室内外热负荷的数值,为暖通空调系统的容量确定提供参考依据。
(二)供热系统的设计供热系统是暖通空调系统中的重要组成部分,主要包括锅炉、循环水泵、换热器、水处理设备等。
供热系统的设计需要考虑到建筑的供热需求和能源利用效率。
根据热负荷计算的结果,确定供热系统的容量,并选择合适的设备以及管道布局,使其满足建筑的采暖需求。
(三)空调系统的设计空调系统主要包括送风系统和排风系统。
送风系统通过空调机组将处理过的新风送入室内,保持室内空气的新鲜和舒适;排风系统通过风机将室内污染的废气排出,提供良好的室内环境。
设计空调系统需要考虑到建筑的通风需求和舒适性要求,合理选择空调机组和风机,并进行合理的布局和管道设计。
三、暖通空调系统的应用技术(一)变频技术变频技术是目前暖通空调系统中广泛应用的技术之一,通过调整设备的运行频率,实现能源的节约和运行的灵活性。
利用变频技术可以根据室内的热负荷情况和人员的需求,调整空调机组的负荷和运行时间,提高系统的能效比。
暖通毕业论文
暖通毕业论文第一篇:暖通毕业论文辽宁建筑职业技术学院毕业论施工安全管理系别:建筑设备系专业班级:供热091班姓名:高双学号:0902060105 指导教师:王青山完成日期:2012 年05月20日文如何进行施工安全管理学生姓名:高双专业:供热通风与空调工程技术班级:供热091班指导教师:王青山职称:教授辽宁建筑职业技术学院2012年 05月辽宁建筑职业技术学院毕业论文摘要在通过对暖通安装工程施工管理中经常遇到的问题深入剖析的基础上,提出改进建议:统一规范图纸要求,熟读图纸;控制好施工材料质量的检验;加强施工人员的素质,提高其专业技能;实现资金和进度的一致,合理有效地配置资源;暖通工程的质量管理和控制应该符合环保要求。
关键词:暖通安装工程施工要点II辽宁建筑职业技术学院毕业论文目录第1章绪论................................................................2 1.1 施工质量的重要性...................................................2 1.1.1施工质量控制的含义...............................................2 1.2 控制好各个分部分项工程.............................................2 1.2.1 加强前期准备...................................................2 1.2.2 加强工程安装阶段的控制.........................................3 1.2.3 工程验收阶段...................................................3 第2章正文................................................................4 2.1暖通安装工程的施工要点分析...........................................4 2.1.1 支架制作安装...................................................4 2.1.2 管道安装.......................................................4 2.1.3 保温施工.......................................................4 2.1.4 预留孔洞封堵检查...............................................5 2.2暖通安装注意事项....................................................5 2.3加强和改进暖通工程施工管理的措施....................................5 2.3.1控制好施工材料质量的检验.........................................6 2.3.2加强施工人员的素质,提高其专业技能...............................6 2.3.3实现资金和进度的一致,合理有效的配置资源.........................6 2.3.4暖通工程的质量管理和控制应该符合环保要求.........................7 结论......................................................................8 参考文献..............................................................9 致谢 (10)III辽宁建筑职业技术学院毕业论文第1章绪论1.1 施工质量的重要性暖通工程是土建或结构的辅助工程,其安装质量好坏直接关系到建筑物的正常使用功能。
暖通空调毕业论文
暖通空调毕业论文暖通空调技术在现代社会中扮演着重要角色。
在建筑物的设计与施工中,暖通空调系统是必不可少的一环。
暖通空调系统不仅能保证室内的温度、湿度、空气质量,还能提高室内舒适度,提高人们的生活质量。
本文将从暖通空调系统的结构、设计原则、运行原理以及维护管理等方面进行分析和论述,希望能够对暖通空调技术有一定的了解和认识。
一、暖通空调系统的结构暖通空调系统主要由冷热源设备、空气处理设备、输送设备以及温控设备组成。
其中,冷热源设备包括空调机组、冷水机组等,空气处理设备包括送风机、新风机、排风机等,输送设备包括风管、水管等,温控设备包括温度传感器、温控器等。
二、暖通空调系统的设计原则设计暖通空调系统时需要考虑以下几个原则:1、合理性原则。
设计时应根据建筑物的用途、结构和环境条件,合理配置冷热源设备、空气处理设备、输送设备和温控设备,以达到使用效果的最佳化。
2、节能性原则。
在设计过程中应考虑节能措施,例如合理利用建筑物本身的自然条件,如采用地热、太阳能等新能源,或采用高效节能设备等,最大程度节约能源。
3、可靠性原则。
设计时应考虑设备和材料的可靠性和耐用性,以确保设备长期稳定运行,减少维修和更换次数。
4、安全性原则。
在设计运行过程中应考虑操作者和使用者的安全,设计时应注意机房的安全和通风等问题,保证安全和健康。
三、暖通空调系统的运行原理暖通空调系统的运行原理是以空气和水为媒介,将室内的热量、湿度、空气质量等进行调节。
具体可以分为以下几个步骤:1、冷热源设备加热或制冷的过程。
空调系统通过制冷剂或空气对冷热源设备进行制冷或加热。
2、空气处理的过程。
空气处理设备对室内空气进行处理,如加湿、除湿、过滤等,使空气质量得到控制。
3、空气输送的过程。
输送设备将经过空气处理的空气输送到各个房间,保证房间内的通风和换气。
4、温度控制的过程。
温控设备对室内的温度进行控制,确保室内温度的稳定和舒适。
四、暖通空调系统的维护管理维护管理是保证暖通空调系统正常运行和延长其使用寿命的重要环节。
暖通设计绿色节能技术研究论文[5篇模版]
暖通设计绿色节能技术研究论文[5篇模版]第一篇:暖通设计绿色节能技术研究论文摘要:暖通系统已经成为了当前我国社会发展中比较常见的一个重要组成部分,其在很多建筑物中都得到了较好运用,为了较好提升这种暖通系统的应用效率,降低其在当前应用中存在较高的能耗问题,必须要重点从绿色节能技术应用方面进行充分分析,采取较为理想的方式进行优化,本文就重点围绕着暖通设计中绿色节能技术的应用进行了简要论述。
关键词:暖通设计;绿色节能技术;应用措施1引言随着当前建筑行业的不断发展,人们对于暖通系统的需求量正在不断增加,这种暖通系统方面的扩展也就必然会对于相应的建筑物运行能耗产生一定的影响,如何促使其能够在发挥相应功效的基础上,尽可能降低能源消耗和浪费,也就成为了今后暖通系统优化改进的一个重要难题。
结合现阶段科学技术的创新发展来看,可以在暖通系统设计中有效应用的技术手段也越来越多,进而也就有助于人们进行合理选用,促使这些绿色节能技术能够较好作用于暖通系统,发挥应有价值。
2暖通系统应用现状分析结合现阶段我国建筑工程项目中对于暖通系统的有效应用而言,其可以说取得了较为高速的发展,在应用数量以及规模方面都存在着较大的突破,进而也就确实表现出了较为理想的作用效果,尤其是对于人们生活质量的优化和提升来看,更是存在着较强的积极作用表现。
但是从另外一个方面来看,这种暖通系统的应用也必然会存在着一些不足和缺陷问题,其带来的消极影响主要表现在以下两个方面:(1)能耗增加。
无论是对于暖通系统应用数量的增加,还是对于暖通系统应用规模的扩大,其都会导致能耗增加,这种能耗增加主要就是随着暖通系统的运行而产生的,而从暖通系统能耗的构成上来看,虽然说确实有大部分的能源消耗是用来改善室内环境,促使其能够更好的满足人们的基本要求,但是同时也必然存在大量的能源消耗是做了无用功,这也就必然会造成能源的浪费,该方面的问题需要在今后暖通系统的优化改进中进行不断完善。