CATALOG电源[1]..
NEMA L6-20 20A,250V AC,2P-3W电源说明书

DescriptionNEMA L6-20 20A, 250V/AC, 2P-3WDesign features for plug & connector• All nylon construction• EPDM gasket seals cord hole from dust and debris •Back wire terminal clamps for easy secure wiring•Individual wiring compartments with tapered channel for easy insertion of wires•Clear cover over wiring compartments allows easy inspection of wiring terminations• Rating printed on side of device•Largest-in-class grommet size allows for entire cord size rangeDesign features for receptacles• Rugged glass filled nylon body•Clearly marked rating, NEMA configuration and approval listings on receptacle face•One piece brass contacts offer superior performance and minimal heat rise•Back and side wiring terminal clamps for easy, secure wiringDesign features for flanged inlet & outlet• All nylon construction• Mounting holes interchangeable with competitive units • Back wire terminal clamps for easy, secure wiring•Individual wiring compartments with tapered channel for easy insertion of wiresIndustrial gradeL6-20 locking devicesCatalog No.DescriptionAmpsVoltsColorAHL620P Ultra grip plug 20250Black & white AHL620C Ultra grip connector 20250Black & white AHL620RSingle receptacle20250Black AHIGL620R Single receptacle, isolated ground 20250Orange AHL620FO Flanged outlet 20250Black & white AHL620FIFlanged inlet20250Black & whiteAHL620PAHL620RAHL620FOAHL620CCompliances, specifications and availability are subject to change without notice.Project Name:Prepared By:Project Number:Date:Catalog Number:Type:T able 1.NEMA L6-20 Industrial Grade Locking Devices2EATON Technical DataEffective January 2014Industrial gradeL 6-20 locking devicesCatalog No.NEMA L6-20 Plug & ConnectorNEMA Config NEMA L6-20Wiring Type Back wireEnvironmental Specifications Flammability: Meets UL94 requirements; V2 ratedTemperature Rating: -40°C to 60°C (-40°F to 140°F)Electrical Specifications Dielectric Voltage: Twice the device rating + 1000V per UL498Current Interrupting: Yes, at full-rated currentTemperature Rise: Max. 30ºC (86°F) after 50 cycles of overload at 150% of rated current (DC)Mechanical Specifications Terminal Accommodation: #14 - #8 AWGVoltage Ratings: Permanently marked on deviceNEMA L6-20 20A, 250V/AC, 2P-3W Catalog No.NEMA L6-20 Plug & ConnectorNEMA Config NEMA L6-20Outer Shell Nylon Interior Body NylonTerminal Retainer Polycarbonate BladesBrassLine Contacts Bronze, tin plated Terminal Clamps Steel, tin platedTerminal Screws #10-32 brass, zinc plated (neutral screw)Ground Screw #10-32 brassAssembly Screws Steel, nickel plated Gasket/Dust Shield EPDMCord Clamp Screws Steel, nickel plated Cord Clamp NylonCompliances, specifications and availability are subject to change without notice.Plug & ConnectorProject Name:Prepared By:Project Number:Date:Catalog Number:Type:T able 2. SpecificationsT able 3. MaterialsProduct DimensionsFigure 1. AHL620P Figure 2. AHL620C Figure 3. Base Angle3EATON Technical DataEffective January 2014Industrial gradeL 6-20 locking devicesCatalog No.NEMA L6-20 Single ReceptacleNEMA L6-20 Isolated Ground Single ReceptacleNEMA Config NEMA L6-20NEMA L6-20Wiring Type Back & side wireBack & side wireEnvironmental Specifications Flammability: Meets UL94 requirements; V0 ratedTemperature Rating: -40°C to 60°C (-40°F to 140°F)Flammability: Meets UL94 requirements; V0 rated Temperature Rating: -40°C to 60°C (-40°F to 158°F)Electrical Specifications Dielectric Voltage: ≤300V: 2000V, 301-600V: 3000V per UL498Current Interrupting: Yes, at full-rated currentTemperature Rise: Max. 30ºC (86°F) after 250 cycles of overload @ 200% of rated current (DC)Dielectric Voltage: ≤300V: 2000V, 301-600V: 3000V per UL498Current Interrupting: Yes, at full-rated currentTemperature Rise: Max. 30ºC (86°F) after 50 cycles of overload @ 150% of rated current (DC)Mechanical Specifications Terminal Accommodation: #14 - #8 AWGVoltage Ratings: Permanently marked on device Terminal Accommodation: #14 - #8 AWG Voltage Ratings: Permanently marked on deviceNEMA L6-20 20A, 250V/AC, 2P-3W Catalog No.NEMA L6-20 Single ReceptacleNEMA L6-20 Isolated Ground Single ReceptacleNEMA ConfigNEMA L6-20NEMA L6-20Face Glass-filled nylon Glass-filled nylon BaseGlass-filled nylonGlass-filled nylonMounting Strap 0.050" thick steel, zinc plated 0.050" thick steel, zinc plated Line Contacts 0.041" thick brass0.041" thick brassTerminal Screws #10-32 brass, nickel plated (neutral screw)#10-32 brass, nickel plated (neutral screw)Ground Screw#10-32 brass (green)#10-32 brass (green)Terminal Clamps/Plates 0.041" thick brass 0.041" thick brass Ground Contacts 0.041" thick brass0.041" thick brassBack Plate0.041" thick brass, nickel plated 0.041" thick brass, nickel plated Mounting ScrewsSteel, zinc platedSteel, zinc platedSingle ReceptaclesT able 4. SpecificationsT able 5. MaterialsProject Name:Prepared By:Project Number:Date:Catalog Number:Type:Product DimensionsFigure 4. AHL620RCompliances, specifications and availability are subject to change without notice.4EATON Technical DataEffective January 2014Industrial gradeL 6-20 locking devicesCatalog No.NEMA L6-20 Flanged OutletNEMA L6-20 Flanged InletNEMA Config NEMA L6-20NEMA L6-20Wiring Type Back wireBack wireEnvironmental Specifications Flammability: Meets UL94 requirements; V2 ratedTemperature Rating: -40°C to 60°C (-40°F to 140°F)Flammability: Meets UL94 requirements; V2 rated Temperature Rating: -40°C to 60°C (-40°F to 140°F)Electrical Specifications Dielectric Voltage: ≤300V: 2000V, 301-600V: 3000V per UL498Current Interrupting: Yes, at full-rated currentTemperature Rise: Max. 30ºC (86°F) after 50 cycles of overload @ 150% of rated current (DC)Dielectric Voltage: ≤300V: 2000V, 301-600V: 3000V per UL498Current Interrupting: Yes, at full-rated currentTemperature Rise: Max. 30ºC (86°F) @ maximum rated current (DC)Mechanical Specifications Terminal Accommodation: #14 - #8 AWGVoltage Ratings: Permanently marked on deviceTerminal Accommodation: #14 - #8 AWG Voltage Ratings: Permanently marked on deviceNEMA L6-20 20A, 250V/AC, 2P-3W Catalog No.NEMA L6-20 Flanged OutletNEMA L6-20 Flanged InletNEMA Config NEMA L6-20NEMA L6-20Outer Shell Nylon Nylon Interior Body NylonNylonTerminal Retainer Polycarbonate Polycarbonate BladesN/A0.062" thick brass Line Contacts 0.031" thick bronze, tin plated N/ATerminal Clamps Steel, tin platedSteel, tin platedTerminal Screws #10-32 brass, nickel plated (neutral screw)#10-32 brass, nickel plated (neutral screw)Ground Screw #10-32 brass (green)#10-32 brass (green)Assembly Screws Steel, nickel plated Steel, nickel plated Mounting Screws Steel, zinc plated Steel, zinc platedCompliances, specifications and availability are subject to change without notice.Flanged Outlet & InletProject Name:Prepared By:Project Number:Date:Catalog Number:Type:T able 6. SpecificationsT able 7. MaterialsProduct DimensionsFigure 5. AHL620FO Figure 6. AHL620FI Figure 7. T op ViewTechnical DataEffective January 2014Industrial gradeL 6-20 locking devicesElectrical Sector 203 Cooper CirclePeachtree City, GA 30269United States Electrical Sector Canada Operations 5925 McLaughlin RoadMississauga, Ontario, L5R 1B8CanadaEatonCanada.ca Electrical Sector Mexico Operations Carr. Tlalnepantla -Cuautitlan Km 17.8 s/n Col. Villa Jardin esq.Cerrada 8 de MayoCuautitlan, Mexico CP 54800Mexico Eaton.mxEaton is a registered trademark. All other trademarks are property of their respective owners.Eaton1000 Eaton Boulevard Cleveland, OH 44122United States © 2014 EatonAll Rights Reserved Printed in USAPublication No. 125-0076-13January 2014Certifications & CompliancesProject Name:Prepared By:Project Number:Date:Catalog Number:Type:AHL620C •••AHL620R ••••••AHIGL620R •••••AHL620FO ••••AHL620FI•••KEY:cULusUL CSAFed SpecNOMROHSParts are manufactured and designed in accordance with article 4 of the European Union’s RoHS2 directive 2011/65/EUCompliances, specifications and availability are subject to change without notice.。
EKCH1506-Catalog-BA

制冷量
1.06 1.03 1.00 0.97 0.94 0.91 0.88
35 制冷输入功率
1.01 1.01 1.00 1.00 1.00 0.99 0.99
制冷量
1.03 1.01 0.98 0.95 0.92 0.89 0.86
40 制冷输入功率
1.13 1.11 1.10 1.09 1.09 1.08 1.08
机组代号 04,05,08,12,15…
3、 W
室外机代号 W:室外机
4、 1
制冷剂代号 1:R410A,0:R407C
5、 LC 功能形式 LC:低温型
6、 A
电源特性 A:220V~/50Hz
7、 AA 产品规格变化的具体描述
EK恒温恒湿空调机组
机组特点
EK恒温恒湿空调机组
电脑控制中心
机组部件描述
高效涡旋式压缩机
全系列采用美国谷轮高效涡旋式压缩 机,效率高,噪音小,故障率低。压 缩机出色的轴向及径向的专利柔性 设计提供了前所未有的耐液击和容 忍杂质的能力,确保压缩机运行安全 稳定。涡旋盘磨合而非磨损设计,随 运行时间的增加表现更出色,寿命更 长,运行更加稳定可靠。
ISO9001:2008 企业质量管理体系认证
ISO14001:2004 环境管理体系认证
产品生产许可证 (XK06-015-00361)
ଶހ CNAS L5123
国家认可实验室
中国CRAA认证
OHSAS18001职业 健康管理体系认证
赫尔辛基—诺基亚全球总部研发中心 (Helsinki- Nokia R&D centers worldwide headquarters)
西门子电源系列说明书

SITOP Power SupplyOrder overview Edition10//sitopSITOP Power SupplyHigh performance. Focused diagnostics.Order overview SITOPRegulated Power Supplies, Expansion modules and DC UPSOutput/TypeRated input voltage (range)Dimensions in mm (WxHxD)Article No.Siemens 1)Short descriptionAdvanced power suppliesSITOP PSU8600 a cloud-enabled power supply complete with open communication protocols and full TIA integrationPSU8600 1AC basic unit • 24 V DC/20 A/4 x 5 A NEW 100 – 240 V AC/110 – 220 V DC (85…275 V AC/99…275 V DC)125 x 125 x 1506EP3336-8MB00-2CY02)• C ompact basic units with 1 or 4 outputs,each overload monitored • E xpandable without wiring effort: Up to 4 CNX8600 modules and 2 BUF8600/UPS8600 modules• E xpansion module for up to 36 outputs• C NX8600 8x2.5 A with NEC Class 2• O utputs individually adjustable:Voltage (4 - 28 V DC) and current• B uffer modules with electrolytic or double-layer capacitors to protect against brief power • U PS module with lead or lithium iron phosphate battery modules to protect against longer powerfailures•T wo Ethernet/PROFINET ports for optimum integration in plants• I ntegrated Web server and OPC UA server • S imple engineering and comprehensive monitoringand diagnosis in TIA Portal• S upport of energy management due to capturingenergy data and selectively switching off the outputsSU8600 3AC basic unit 400-500 V 3 AC,(320 … 575 V 3 AC)• 24 V DC/20 A 80 x 125 x 1506EP3436-8SB00-2AY0• 24 V DC/20 A/4 x 5 A 100 x 125 x 1506EP3436-8MB00-2CY0• 24 V DC/40 A 125 x 125 x 1506EP3437-8SB00-2AY0• 24 V DC/40A/4 x 10 A 125 x 125 x 1506EP3437-8MB00-2CY0Modular system:Supply from basic unitPSU8600 via connection…System Clip Link“CNX8600 expansion module • 24 V DC/4 x 5 A 60 x 125 x 1506EP4436-8XB00-0CY0• 24 V DC/4 x 10 A 60 x 125 x 1506EP4437-8XB00-0CY0• 24 V DC/8 x 2,5 A NEC Class2100 x 125 x 1506EP4436-8XB00-0DY0BUF8600 buffer module• 100 ms/40 A 60 x 125 x 1506EP4297-8HB00-0XY0• 300 ms/40 A 125 x 125 x 1506EP4297-8HB10-0XY0• 4 s/40 A 60 x 125 x 1506EP4293-8HB00-0XY0• 10 s/40 A 125 x 125 x 1506EP4295-8HB00-0XY0UPS components • U PS module UPS86060 x 125 x 1506EP4197-8AB00-0XY0• B attery module BAT8600 Pb Energy exchange withUPS8600322 x 187 x 1106EP4145-8GB00-0XY0• B attery module BAT8600LiFePO4322 x 187 x 1106EP4143-8JB00-0XY0SITOP PSU8200 Technology power supply for demanding solutions24 V DC/5 A, PSU8200120/230 V AC(85 … 132/176 … 264 V AC)45 x 125 x 1256EP3333-8SB00-0AY0• Wide-range input• Efficiency levels of up to 95%• E xtra power feature (1.5 x I rated for 5 s/min for brief operational overload • P ower Boost (3 x I rated for 25 ms)for triggering protective equipment •S witchable characteristic curves for parallel operation and short-circuit protection • O peration status indicated by 3 LEDs •O utput voltage adjustable •24 V power supply units expandable with add-on modules and DC UPS• 36 V and 48 V versions enable smallercross-sections of the load supply lines 24 V DC/10 A, PSU820055 x 125 x 1256EP3334-8SB00-0AY024 V DC/5 A, PSU200M 120 – 230/230 – 500 V AC (85 … 264/176 … 550 V AC)70 x 125 x 1256EP1333-3BA1024 V DC/10 A, PSU200M 70 x 125 x 1256EP1334-3BA1024 V DC/20 A, PSU8200120/230 V AC (85 … 275 V AC/88 … 350 V DC)90 x 125 x 1256EP1336-3BA1024 V DC/40 A, PSU8200120/230 V AC (95 … 132/190 … 264 V AC)145 x 145 x 1506EP3337-8SB00-0AY024 V DC/20 A, PSU8200400 – 500 V 3 AC (320 … 575 V 3 AC)70 x 125 x 1256EP3436-8SB00-0AY024 V DC/40 A, PSU8200135 x 145 x 1506EP3437-8SB00-0AY036 V DC/13 A, PSU8200 70 x 125 x 1256EP3446-8SB10-0AY048 V DC/10 A, PSU820070 x 125 x 1256EP3446-8SB00-0AY048 V DC/20 A, PSU8200400 – 500 V 3 AC (340 … 550 V 3 AC)135 x 145 x 1506EP3447-8SB00-0AY02)Standard power suppliesSITOP PSU6200 – The all-rounder power supply for a wide variety of applications12 V DC/2 A, PSU6200120 – 230 V AC/120 – 240 V DC (85 … 264 V AC/110 … 275 V DC)25 x 100 x 886EP3321-7SB00-0AX0• Robust wide range input AC and DC, 3-phase devicesalso applicable for continuous operation with2 phases• Space-saving, narrow design• High efficiency up to 96%• High overload capacity thanks to Extra-Power (1.5 x I nom for 5 s) and constant current behavior• Permanent overload capacity (1.2 x I nom )up to 45 °C ambient temperature• Push-in terminals for fast connection• From 3.7 A: LED and signaling contact“DC OK”• From 10 A: Diagnostics monitor for overload andservice life via LEDs Diagnostics interface signals allthe relevant device and operating data. Active PFC forlow reactive current component• E xpandable with all SITOP add-on modules 24 V DC/1,3 A, PSU620025 x 100 x 886EP3331-7SB00-0AX024 V DC/2,5 A, PSU620040 x 100 x 886EP3332-7SB00-0AX024 V DC/3,7 A,NEC Class2, PSU6200120 – 230 V AC/120 – 240 V DC (85 … 264 V AC/99 … 275 V DC)35 x 135 x 1256EP3333-7LB00-0AX024 V DC/7 A, PSU620035 x 135 x 1256EP3323-7SB00-0AX024 V DC/5 A, PSU620035 x 135 x 1256EP3333-7SB00-0AX012 V DC/12 A, PSU6200120 – 230 V AC/110 – 240 V DC (85 … 264 V AC/85 … 275 V DC)45 x 135 x 1256EP3324-7SB00-3AX024 V DC/10 A, PSU620045 x 135 x 1256EP3334-7SB00-3AX024 V DC/20 A, PSU620070 x 135 x 1556EP3336-7SB00-3AX024 V DC/5 A, PSU6200NEW 400 – 500 V 3 AC(323 – 576 V 3 AC)35 x 135 x 1256EP3433-7SB00-0AX02)24 V DC/10 A, PSU6200 NEW 45 x 135 x 1556EP3434-7SB00-3AX02)24 V DC/20 A, PSU6200 NEW70 x 135 x 1556EP3436-7SB00-3AX02)SITOP smart – Powerful standard power supply12 V DC/7 A, PSU100S 120/230 V AC(85 … 132/170 … 264 V AC)50 x 125 x 1206EP1322-2BA00• S pace-saving, slim design • P SU100S with automatic range switch over 120/230 V AC • E xtra-Power (1.5 x I rated for 5 s) for brief operational overload • P ermanent overload capacity (1.2 x I rated ) to 45 °C ambient temperature (24 V devices)• G reen LED and signaling contact …Output voltage OK”• A djustable output voltage up to 28.0 V DC or 15.5 V DC (12 V devices)• E xpandable with, redundancy module, selectivity/diagnostics module, buffer module and DC UPS12 V DC/14 A, PSU100S 70 x 125 x 1206EP1323-2BA0024 V DC/2.5 A, PSU100S 32,5 x 125 x 1206EP1332-2BA2024 V DC/5 A, PSU100S 50 x 125 x 1206EP1333-2BA2024 V DC/10 A, PSU100S 70 x 125 x 1206EP1334-2BA2024 V DC/20 A, PSU100S 115 x 145 x 1506EP1336-2BA1024 V DC/5 A, PSU300S 400 – 500 V 3 AC (340 … 550 V 3 AC)50 x 125 x 1206EP1433-2BA2024 V DC/10 A, PSU300S 70 x 125 x 1206EP1434-2BA2024 V DC/20 A, PSU300S 90 x 145 x 1506EP1436-2BA1024 V DC/40 A, PSU300S150 x 145 x 1506EP1437-2BA20Basic power suppliesSITOP lite – Cost-effective basic power supply24 V DC/2.5 A, PSU100L 120/230 V AC(93 ... 132/187 ... 264 V AC)32,5 x 125 x 1206EP1332-1LB00• F or industrial applications and basic requirements •N arrow width • G reen LED for “24 V OK”•A djustable output voltage 24 V DC/5 A, PSU100L 50 x 125 x 1206EP1333-1LB0024 V DC/10 A, PSU100L 70 x 125 x 1206EP1334-1LB0024 V DC/20 A, PSU100L100 - 240 V AC (85 ... 264 V AC/88 … 370 V DC)110 x 125 x 1256EP1336-1LB00LOGO!Power 4th generation – Flat power supply for distribution boards in LOGO! 8 design5 V DC/3.0 A 100 – 240 V AC (85 … 264 V AC/110 … 300 V DC)36 x 90 x 536EP3310-6SB00-0AY0•T he 4th generation with even more power in a smaller space: every performance class is 18 mm(1 modular width) narrower•N ew performance class only 18 mm wide • Wide-range AC and DC input• Voltage measuring point for output current•U p to 90% efficiency over entire load range • V ery low no-load losses of < 0.3%• C onstant current and power reserve for loads withhigh inrush currents• F lexible rail or wall mounting • G reen LED for “Output voltage OK”• A djustable output voltage• T emperature range -25 ... +70 °C 5 V DC/6.3 A 54 x 90 x 536EP3311-6SB00-0AY012 V DC/0.9 A 18 x 90 x 536EP3320-6SB00-0AY012 V DC/1.9 A 36 x 90 x 536EP3321-6SB00-0AY012 V DC/4.5 A 54 x 90 x 536EP3322-6SB00-0AY015 V DC/1.9 A 36 x 90 x 536EP3321-6SB10-0AY015 V DC/4.0 A 54 x 90 x 536EP3322-6SB10-0AY024 V DC/0.6 A 18 x 90 x 536EP3330-6SB00-0AY024 V DC/1.3 A 36 x 90 x 536EP3331-6SB00-0AY024 V DC/2.5 A 54 x 90 x 536EP3332-6SB00-0AY024 V DC/4 A72 x 90 x 536EP3333-6SB00-0AY0Power supply in SIMATIC-Design24 V DC/2.5 A, PM1207120/230 V AC(85 … 132/176 … 264 V AC)70 x 100 x 756EP1332-1SH71• C ompact Power Module for the S7-1200with automatic range switchover24 V DC/2 A, PS307120/230 V AC(85 … 132/170 ... 264 V AC)40 x 125 x 1206ES7307-1BA01-0AA0• S ystem and load power supply for theS7-300 in new narrow design withautomatic range switchover24 V DC/5 A, PS30760 x 125 x 1206ES7307-1EA01-0AA024 V DC/10 A, PS30780 x 125 x 1206ES7307-1KA02-0AA024 V DC/3 A, PM1507 120/230 V AC(85 … 132 V/170 ... 264 V AC) 50 x 147 x 1356EP1332-4BA00• L oad power supply of S7-1500 in slimline design with automatic range switchoverand extra power (1.5 x I rated for 5 s/min)24 V DC/8 A, PM1507 75 x 147 x 1356EP1333-4BA0024 V DC/5 A, ET 200SP PS 120/230 V AC(85 … 132 V/170 ... 264 V AC)160 x 117 x 756EP7133-6AB00-0BN0• P ower supply for SIMATIC ET 200SP distributed I/O,flat design, with automatic range selection, extrapower (1.5 x I rated for 5 s/min), current monitor and plugs for 6 load circuits 24 V DC/10 A, ET 200SP PS 6EP7133-6AE00-0BN024 V DC/8 A, ET200pro PS400 – 480 V 3 AC (340 ... 550 V 3 AC)310 x 135 x 906ES7148-4PC00-0HA0• P ower supply in degree of protectionIP67 for electronics/sensors and load voltage for the SIMATIC ET200proDC/DC converter24 V DC/4 A, PSU340012 V DC (9 … 18 V DC)32 x 100 x 1006EP3133-0TA10-0AY0• S table output voltage from fluctuatingDC voltage• I deal for battery-operated applications such as driverless transport vehicles • P SU3400 in narrow metal housing,with reverse polarity protection and high efficiency up to 93.5%• P SU3400 24 V DC/24 V DC for compensating voltagelosses with long cables 12 V DC/8 A, PSU340024 V DC (14 … 32 V DC)startup from 18 V32 x 100 x 1006EP3123-0TA00-0AY012 V DC/15 A, PSU340042 x 125 x 1206EP3124-0TA00-0AY024 V DC/5 A, PSU340032 x 100 x 1006EP3133-0TA00-0AY024 V DC/10 A, PSU340042 x 125 x 1206EP3134-0TA00-0AY024 V DC/3,5 A,NEC Class 2, PSU340048 V DC (28 … 54 V DC) startup from 36 V 32 x 100 x 1006EP3233-0TA10-0AY024 V DC/5 A, PSU34032 x 100 x 1006EP3233-0TA00-0AY024 V DC/10 A, PSU3400 42 x 125 x 1206EP3234-0TA00-0AY024 V DC/20 A, PSU400M600 V DC (300 … 900 V DC) startup from 340 V 90 x 125 x 1256EP1536-3AA00• H igh input voltage, e.g. for operation at the DC link of drives • H igh efficiency of 95%1)C urrent ordering data plus terms and conditions of sale and delivery can be found in the Catalog KT10.1 and in the Internet at/industrymall 2)Planned start of delivery: 1st quarter 2020© Siemens 2019。
Recom PA-1 电源说明书

RAC03-12SER/277-TRA Y RAC03-24SER/277-TRAYRAC03-3.3SER/277-TRAYRAC03-24SER/277Refer to Applications NotesAny data referred to in this datasheet are of indicative nature and based on our practical experience only. For futher details,please refer to Application NotesAC/DC Co nverterPA-1REV.: 0/20153 YE A Rw ar r a n t y3Specifications (measured at T A = 25°C, nominal input voltage, full load and after warm-up)BASIC CHARACTERISTICSParameterCondition Min.Typ.Max.Input Voltage Range 85VAC 120VDC305VAC 430VDCInput Currentfull load, 115VAC full load, 230VAC 70mA 45mAabsolute max. Input Current cold start at 25°C, 115VAC cold start at 25°C, 230VAC 15A 30A No load Power Consumption 85-305VAC, 47-440Hz40mW Input Frequency AC Input 47Hz440Hz Leakage Current 85-305VAC, 47-440Hz10µAHold-up time full load18ms Operating Frequency 100% load at nominal Vin55kHzEfficiency see Selection GuideMinimum Load 10%Output Ripple and Noise3.3Voutall others250mVp-p 200mVp-pDescriptionThe modules of the RAC03-SER/277 series are regulated AC/DC converters with 3kVAC isolation and a round, flat shape. This series has been designed to offer low stand-by consumption and an ultra-wide input voltage range. Uses include a variety of applications in building automation, security systems and communication systems.E224736FeaturesRegulated Converters• 40mW max. No Load Power Consumption • High Efficiency up to 76%• Isolated Output 3kVAC / 1 min • SCP, OVP Protection• Wide Operating Temperature Range: -40°C to +85°C• Universal Input 85-305VAC3 Watt Single OutputRAC03-SER/277Selection GuidePart Input Output Output Efficiency Max. Capacitive Number Voltage Range Voltage Current typ. Load (VAC) (VDC) (mA) (%) RAC03-3.3SER/277 85-305 3.3 900 68 22000µF RAC03-05SER/277 85-305 5.0 600 70 7500µF RAC03-12SER/277 85-305 12 250 74 1000µF RAC03-24SER/277 85-305 24 125 76 200µFAC/DC Co nverterPA-2REV.: 0/PROTECTIONSParameterType ValueShort Circuit Protection (SCP)continuous, automatic recoveryOver Voltage Protection (OVP)Zener Diode clamp120% - 190%Over Current Limit 105% - 150%Isolation Voltage 3kVAC / 1 MinuteIsolation Resistance1G Ω min.Specifications (measured at T A = 25°C, nominal input voltage, full load and after warm-up)REGULATIONSParameterConditionValueOutput Voltage Tolerance (2)3.3Vout 5Vout 12, 24Vout±4% typ. / ±8% max.±3.5% typ. / ±5% max.±3% typ. / ±4% max.Line Voltage Regulation low line to high line, full load ±0.7% typ. / ±1% max.Load Voltage Regulation10% to 100% load; 3.3Vout 10% to 100% load; 5Vout 10% to 100% load; 12, 24Vout±5.5% typ. / ±9% max.±5% typ. / ±7.5% max.±4% typ. / ±5.5% max.RAC03-SER/277SeriesNotes:Note2:Includes initial voltage accuracy, thermal drift, line regulation and load regulation at rated input voltage and load conditions.AC/DC Co nverterPA-3REV.: 0/2015Specifications (measured at T A = 25°C, nominal input voltage, full load and after warm-up)RAC03-SER/277SeriesSAFETY AND CERTIFICATIONSCertificate TypeReport / File NumberStandard EN General Safety SPCLVD1208051EN-60950-1, 2nd Edition UL General SafetyE224736UL-60950-1, 2nd EditionCertificate Type (Environmental)Report / File Number Standard / CriterionESDRadiated Immunity Fast Transient SurgeConducted ImmunityVoltage dips and variations Voltage flicker EN61000-4-2, Criteria B EN61000-4-3, Criteria A EN61000-4-4, Criteria B EN61000-4-5, Criteria B EN61000-4-6, Criteria A EN61000-4-8, Criteria AEN-61000-3-3EMI StandardReport: 1502CE17EN55022, Class BEN55024RAC03-05SER/277AC/DC POWER SUPPLYPRI: 100-277V~, 50/60Hz, 4.3W SEC: 5V , 600mA max.The product information and specifications are subject to change without prior notice. All products are designed for non-safety critical commercial and industrial applications.The buyer agrees to implement safeguards that anticipate the consequences of any failures that might cause harm, loss of life and/or property damage.RAC03-12SER/277-TRA Y RAC03-24SER/277-TRAYRAC03-3.3SER/277-TRAYRAC03-24SER/277。
VAHLE CPS 无接触无线电源5A 20kHz系列产品介绍(英文)说明书

YOUR VISION – OUR SOLUTION5A | EN | Rev.032CPS® – KEY HIGHLIGHTS3 GENERAL CPS® OPERATING PRINCIPLETRANSFORMER PRINCIPLEVAHLE CPS® technology provides electrical energy without any mechan-ical contact. It utilizes the induction principle similar to a transformer‘s primary/secondary transfer. In a transformer, the primary and second-ary windings are on a common, closed ferromagnetic core. CPS® tech-nology, on the other hand, …stretches“ the primary winding to a long loop and places the secondary winding onto an open ferromagnetic core. This allows relative motion of the two windings. The transmission character-istics are optimized by using a high transmission frequency of 20 kHz.CPS®TECHNOLOGY4CPS ® – SYSTEM OVERVIEW1 PPU Primary Unit2 Track Power Litz Cable3 Guidance4 F-PU: Flat PickupPRIMARY EQUIPMENT – OVERVIEWCOMPLETE CABINET 45 KW / 11 KW• Cabinet ready for use• Technical design depending on installed system • Design according to customer specifications• Several cabinets can be interconnected for large systems with a high power requirementsMOUNTING PLATE 45 KW / 11 KW• All 20 kHz CPS ® components are pre-mounted and completely wired • Installation in an existing power switch cabinet • Supply with 400 V, three-phase alternating current • 20 kHz output for supplying the primary loopCABINET PRIMARY INVERTERAs the centerpiece of the contactless power supply, the primary inverter delivers the required electrical power for all mobile consumers located on the track. Standard three-phase alternating current of 400 V / 50 Hz (or different regional standards) is initially converted to single-phase alternating current of 20 kHz and then fed to the primary cable at a constant current of 70 A. A suitable diagnostics interface is available for displaying or moni-toring the actual operating condition.42135PRIMARY POWER UNITPPU45K – 45 KWTECHNICAL DATAELECTRICAL DATAPower (nominal/peak) ...........8.8 kW / 11 kW (PPU11K)Power (nominal/peak) ...........36 kW / 45 kW (PPU45K)Supply voltage ........................3 x 400 VACMECHANICAL DATADimension............................... 2000 x 1200 x 500 mm + 200 m socket(complete cabinet)1900 x 700 mm (mounting plate)Temperature range ................0 – 30°CProtection Type ....................... I P54 (complete cabinet)IP00 (mounting plate)Mounting plateComplete cabinet PL8x4PPU45k.2-020-072-A-IO Primary power unit 45 kW / Feed-through terminal for standard application / 20 kHz / 72 A / Stand alone / Digital IOs / Track compensation not included 10022801PPU45k.2-020-072-M-IO Primary power unit 45 kW / Feed-through terminal for standard application / 20 kHz / 72 A / Sync-Master / Digital IOs / Track compensation not included 10022821PPU45k.2-020-072-U-IO Primary power unit 45 kW / Feed-through terminal for standard application / 20 kHz / 72 A / Sync-Sub-Slave / Digital IOs / Track compensation not included 10022807PPU45k.2-020-072-S-IOPrimary power unit 45 kW / Feed-through terminal for standard application / 20 kHz / 72 A / Sync-Slave / Digital IOs / Track compensation not included10022808RANGE OF PRODUCTSDescriptionOrder No.P-SK-0220NF-0400-015-028-300-000-0-000+VTuning-Compensation for PPU15..28X220NF 0915125-9 P-SK-0150NF-0600-015-028-300-000-0-000+VTuning-Compensation for PPU15..28X150NF 0915125-8 P-SK-0100NF-0600-015-028-300-000-0-000+VTuning-Compensation for PPU15..28X100NF 0915125-7 P-SK-0068NF-0650-015-028-300-000-0-000+VTuning-Compensation for PPU15..28X68NF 0915125-6 P-SK-0047NF-0650-015-028-300-000-0-000+VTuning-Compensation for PPU15...28X47NF0915125-5TRACK COMPENSATION (MOUNTING PLATE)RANGE OF PRODUCTSDescription Order No.124 AHF50PPU11k.1-020-124-A-IO Primary power unit 11 kW / Terminal screw for standard application / 20 kHz / 124 A / Stand alone / Digital IOs / Track compensation not included10022809PPU11k.1-020-124-M-IO Primary power unit 11 kW / Terminal screw for standard application / 20 kHz / 124 A / Sync-Master / Digital IOs / Track compensation not included10022810PPU11k.1-020-124-U-IO Primary power unit 11 kW / Terminal screw for standard application / 20 kHz / 124 A / Sync-Sub-Slave / Digital IOs / Track compensation not included 10022811PPU11k.1-020-124-S-IOPrimary power unit 11 kW / Terminal screw for standard application / 20 kHz / 124 A / Sync-Slave / Digital IOs / Track compensation not included1002281272 AHF25PPU11k.1-020-072-A-IO Primary power unit 11 kW / Terminal screw for standard application / 20 kHz / 72 A / Stand alone / Digital IOs / Track compensation not included10022813PPU11k.1-020-072-M-IO Primary power unit 11 kW / Terminal screw for standard application / 20 kHz / 72 A / Sync-Master / Digital IOs / Track compensation not included100228147 PRIMARY EQUIPMENT CONFIGURATIONThe primary inverter units shown here are generally suitable for all areas of application indicated in this catalog. From a technical and economical aspect, an optimum adaptation to the respective conditions of a specific installation is assured due to an available, wide-ranging performance grading scale. Whether a complete cabinet is needed or a mounting plate – our experienced project team will always be glad to help you selecting the best suitable components.Primary equipment can be configured for installations with one segment (stand alone) or for installations with several segments.A system with two segments consists of a master unit and a slave unit. A system with more than two segments consists of a master unit, sub-slave units and a slave unit.Examples: S ystem with two segments: 1 x master and 1 x slave.System with four segments: 1 x master, 2 x sub-slave and 1 x slaveCONFIGURATION FOR 124 ACONFIGURATION FOR 72 ASystem with one segment System with several segmentsStand alone Stand alone PU22Master Sub-Slave SlavePrimary cable HF50PPU45k.1-020-124-A-IO PPU45k.3-020-124-A-IO PPU45k.1-020-124-M-IO PPU45k.1-020-124-U-IO PPU45k.1-020-124-S-IO PPU11k.1-020-124-A-IO PPU11k.1-020-124-M-IO PPU11k.1-020-124-U-IO PPU11k.1-020-124-S-IOF-Pickup E-Pickup F-Pickup F-Pickup F-PickupU-Pickup U-Pickup U-Pickup U-PickupPrimary cable PL8x4PPU45k.2-020-072-A-IO PPU45k.2-020-072-M-IO PPU45k.2-020-072-U-IO PPU45k.2-020-072-S-IOPPU11k.2-020-072-A-IO PPU11k.2-020-072-M-IO PPU11k.2-020-072-U-IO PPU11k.2-020-072-S-IO F-Pickup system F-Pickup system F-Pickup system F-Pickup system8TRACK EQUIPMENTTrack Power Compensation BoxTRACK COMPENSATION KB 10.1Dimensions (L x W x H) ............194 x 154 x 100Protection Type .......................IP65Weight .....................................1.5 kg Track current ..........................72 ATRACK COMPENSATION KB 10.4Dimensions (L x W x H) ............2x 440 x 156 x 110Protection Type .......................IP54Weight .....................................4 kg Track current ..........................124 ATRACK COMPENSATION• Compact design• Positioning near track possible • A box is required every 33 to 44 mPRIMARY CABLEPRIMARY CABLE HF 25Application ..............................EMS Diameter .................................11 mm Weight .....................................0.28 kg/m• For EMS and sortation technology applications• Special conductor made of single insulated copper braid • Small outside diameterPRIMARY CABLE HF 50Application ................ F loor skid conveyor/crane installationsDiameter .................................16.5 mm Weight .....................................0.56 kg/m• For very long track sections • Special conductor made of single insulated copper braid• Very low power loss due to large conductor cross sectionPRIMARY CABLE 8 X 4Application ................Floor skid conveyor Diameter .................................15.7 mm Weight .....................................0.49 kg/m• For standard applications • Single insulated copper conductors • Easy installation with standard cable tools10VEHICLE EQUIPMENT FOR 24 V / 27 VF-PICKUP PS08 WITH INTEGRATED REGULATORDescriptionOrder No.PS08-0027V019AD-00000000-1C103-00310+VPS08 / 0.5 kW / 20 kHz / Track conductor spacing 80 mm / integrated Regulator / 27 VDC / 19 A max / Battery Charging 0915429-3E21PS08-0600W024VD-00000000-1C102-00300+V PS08 / 0.6 kW / 20 kHz / Track conductor spacing 80 mm /integrated Regulator / 24 VDC / 25 A max0915429-1A11AL-5X2,5Cable connection between PS08 and external applicationsee page 22RANGE OF PRODUCTSBLOCK DIAGRAMDC-OUTPUTDIMENSIONS TECHNICAL DATAELECTRICAL DATAPeak power .............................0.6 / 0.5 kWNominal power .......................0.35 kWOutput voltage ........................24 / 27 VDC ±5 %Output current max ................25 / 19 ADuty cycle ................................depending on coolingTrack current ..........................72 ATrack frequency ......................20 kHzTrack conductor spacing ........80 mmPROTECTIONOutput over current ................YesMax. reverse voltage ..............30 VDCPICKUP SYSTEM MECHANICAL DATA Dimension...............................310 x 210 x 133 mmMounting holes.......................120 x 290 mm / 160 x 190 mm Weight .....................................12.8 kgNominal airgap .......................20 mmVertical tolerances .................−20 mm @ 100%, +10 mm derating Lateral tolerances ..................±15 mm @ 100%, ±30 mm derating Protection rating .....................I P20 with open plug connectionIP54 with plug connected Ambient temperature .............0 ... +30°C non-condensing Environment ...........................General industrialCooling ....................................Natural convectionVEHICLE EQUIPMENT FOR 24 V / 28.2 V / 56.2 VF-PICKUP PS27.1 WITH INTEGRATED REGULATORRANGE OF PRODUCTSBLOCK DIAGRAMDC-OUTPUTDescriptionOrder No.PS27.1-1000W024VD-00000000-1A002-0030L+VPS27.1 / 1 kW / 20 kHz / Track conductor spacing 100 mm / integrated Regulator / 24 VDC / 42 A max10011549PS27.1-28.2V036AD-00000000-1B002-0031L+VPS27.1 / 1 kW / 20 kHz / Track conductor spacing 100 mm / integrated Regulator / 28.2 VDC / 36 A max. / Battery Charging 10014177PS27.1-56.2V020AD-00000000-1B002-0031L+V PS27.1 / 1 kW / 20 kHz / Track conductor spacing 100 mm / integrated Regulator / 56.2 VDC / 20 A / Battery Charging 10014214AL-7G2,5Cable connection between PS27.1 and external applicationsee page 22DIMENSIONS TECHNICAL DATAELECTRICAL DATAPeak power .............................1 kW (10 s)Nominal power .......................0.6 kWOutput voltage ........................24 / 28.2 / 56.2 VDC ±10 %Output current max ................46.5 / 40 / 20 ADuty cycle ................................40 % Duty (10 min cycle)Track current ..........................72 ATrack frequency ......................20 kHzTrack conductor spacing ........100 mmPROTECTIONOutput over current ................YesMax. reverse voltage ..............30 VDCPICKUP SYSTEM MECHANICAL DATA Dimension...............................405 x 245 x 142 mmMounting holes.......................225 x 280 mmWeight .....................................16 kgNominal airgap .......................15 mmVertical tolerances .................−15 mm @ 100%, +20 mm derating Lateral tolerances ..................±30 mm deratingProtection rating .....................I P20 with open plug connectionIP54 with plug connected Ambient temperature .............0 ... +30°C non-condensing Environment ...........................General industrialCooling ....................................Natural convectionVEHICLE EQUIPMENT FOR 560 VF-PICKUP F330 AND REGULATOR RE330RANGE OF PRODUCTSBLOCK DIAGRAMDC-OUTPUTREADYDescriptionOrder No.vPOW_F330.1-020-124-04-L0-HV F330 / 3.3 kW / 20 kHz / 124 A / Duty 40 % / Linear 10017749vPOW_RE330.1-020-560-04-NI-ST-RC-NI Regulator / 3.3 kW / 20 kHz / 560 V / Duty 40 % /No thermal monitoring / LITE / Relay contact / No Auxiliary 10017419PX12Cable connection between F330 and RE330see page 22DIMENSIONSTECHNICAL DATAELECTRICAL DATAPeak power .............................3.3 kW Nominal power .......................1.3 kW Output voltage ........................560 VDC ±5 %Output current max ................6.5 ADuty cycle ................................40 % duty (10 min cycle)Track current ..........................124 A Track frequency ......................20 kHz Track conductor spacing ........100 mm PROTECTIONOutput over voltage ................Yes Output over current ................Yes Max. reverse voltage ..............750 VDCREGULATOR MECHANICAL DATADimension...............................190 x 120 x 87.4 mm Mounting holes.......................180.5 x 80 mm Weight .....................................1 kg Protection rating .....................IP20Ambient temperature .............0 ... +40°C non-condensing Environment ...........................General industrial Cooling ....................................Forced convectionPICKUP CONNECTION CABLELength .....................................1/2/4/6 m Outer diameter .......................11 mm Connections ............................Pre-terminated Application ..............................Flexible Min. bending radius ...............50 mmVEHICLE EQUIPMENT FOR 48 VU-PICKUP PK31 AND REGULATOR RE080DescriptionOrder No.PK31 -0900W110VA-VLPK1000-19I00-8000K+VPK31 / 900 W / 20 kHz / Nominal power 400 W / 1 m connecting cable 10020600RE080.1-20-048-03-UC-LI-NI-NI Regulator / 0.8 kW / 20 kHz / Duty 30 % / 48 V / Thermal monitoring / LITE / Relay contact / No Auxiliary10021229AL-3G4Cable connection between RE080 and external applicationsee page 22RANGE OF PRODUCTSBLOCK DIAGRAMDC-OUTPUT 1DC-OUTPUT 2USBDIMENSIONS TECHNICAL DATAELECTRICAL DATAPeak power .............................0.8 kW (5 s)Nominal power .......................0.26 kWOutput voltage ........................48 VDC ±5 %Output current max ................18 ADuty cycle ................................30 % (10 min cycle)Track current ..........................72 ATrack frequency ......................20 kHzTrack conductor spacing ........67 mmPROTECTIONOutput over voltage ................YesOutput over current ................YesOver temperature ...................YesREGULATOR MECHANICAL DATA Dimension...............................304 x 220 x 94.5 mm Mounting holes.......................204 x 175 mmWeight .....................................3.7 kgProtection rating .....................I P20 with open plug connectionIP54 with plug connected Ambient temperature .............5 ... +40°C non-condensing Environment ...........................General industrialCooling ....................................Natural convectionPICKUP CONNECTION CABLELength .....................................1 mOuter diameter .......................11.2 mmConnections ............................Pre-terminatedApplication ..............................FlexibleMin. bending radius ...............40 mmPICKUP MECHANICAL DATA Dimension...............................114 x 75 x 89.4 mm Mounting holes.......................86 x 47 mmWeight .....................................1.6 kgNominal airgap .......................12.5 mmVertical tolerances .................±3 mmLateral tolerances ..................+4 / −12.5mm @ 100%VEHICLE EQUIPMENT FOR 560 VE-PICKUP PUE4 AND REGULATOR RE55RANGE OF PRODUCTSBLOCK DIAGRAMDC-OUTPUTTEMPERATURE WARNINGDescriptionOrder No.PUE4-4000W270VA-00000000-12E00-00E00+VPUE4 / 4 kW / 20 kHz / Nominal power 3.2 kW / 200 mm connecting cable 10005185RE55.1-5500W560VD-000W00VD-11014-0030X+V RE55.1 / 5.5 kW / 20 kHz / 560 VDC 10016225VL-7G2,5Cable connections between PUE4 and RE55see page 22DIMENSIONS TECHNICAL DATAELECTRICAL DATAPeak power .............................4 kW (5 s)Nominal power .......................1.3 kWOutput voltage ........................560 VDC ±10 %Output current max ................8 ADuty cycle ................................30 % (10 min cycle)Track current ..........................72 ATrack frequency ......................20 kHzTrack conductor spacing ........84 mmPROTECTIONOutput over current ................YesMax. reverse voltage ..............800 VDCREGULATOR MECHANICAL DATA Dimension...............................282 x 247 x 169 mm Mounting holes.......................215 x 214 mmWeight .....................................7.2 kgProtection rating .....................I P20 with open plug connectionIP54 with plug connected Ambient temperature .............5 ... +40°C non-condensing Environment ...........................General industrialCooling ....................................Natural convectionPICKUP CONNECTION CABLELength .....................................0.2/1/2/3/4.5 mVEHICLE EQUIPMENT FOR 288 V / 560 VE-PICKUP PU22 AND REGULATOR RE22RANGE OF PRODUCTSBLOCK DIAGRAMDC-OUTPUT 1DC-OUTPUT 2DescriptionOrder No.PU22-022KW310VA-00000000-00000-00C00+VPU22 / 22 kW / 20 kHz / Mounting on narrow side 0915007-120PU22-022KW310VA-00000000-00000-00D00+VPU22 / 22 kW / 20 kHz / Mounting on long side0915007-220RE22-040KW288VD-1K6W24VD-25A11-13400+VRE22 / 40 kW / 20 kHz / 2 x PU22 / 288 VDC / Auxilliary / 1.6 kW / 24 VDC 0915011-0218RE22-040KW560VD-960W24VD-25A00-00400+V RE22 / 40 kW / 20 kHz / 2 x PU22 / 560 VDC / Auxilliary / 0.19 kW / 24 VDC 0915011-0200AL-5G16Cable connections between PU22 and RE22see page 2221DIMENSIONSTECHNICAL DATAELECTRICAL DATAPeak power .............................22 / 40 kW * (10 s)Nominal power .......................10 / 25 kW *Output voltage ........................288 / 560 VDC ±10 %Output current max ................155 / 80 A Track current ..........................124 A Track frequency ......................20 kHz Track conductor spacing ........133 mmPROTECTIONOutput over voltage ................Yes Output over current ................YesREGULATOR ELECTRONIC MECHANICAL DATADimension...............................328 x 660 x 290 mm Mounting holes.......................200 x 630 mm Weight .....................................31.5 kg Protection rating .....................IP20Ambient temperature .............0 ... +30°C non-condensing Environment ...........................General industrial Cooling ....................................Forced convectionVariant PU22 xxx-120Power CablesPAUL VAHLE GmbH & Co. KGWesticker Str. 5259174 Kamen Germany Phone: +49 2307 704-0*************VAHLE Incorporated 407 Cane Island Pkwy Katy, TX, 77494, USA Phone: +1 713-465-9796 ******************connect with us! @vahleincW 1103931/00/e n | 0 | R e v .03 | 03/20 | E r r o r s a n d t e c h n i c a l m o d i f i c a t i o n s s u b j e c t t o c h a n g e .。
电源设备手册说明书

7Vacuum Contactors and StartersSize 4 Vacuum Contactor7.1NEMA, Special Purpose and Mining RatingProduct Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V5-T7-2Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V5-T7-2Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V5-T7-2Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V5-T7-2Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V5-T7-2Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V5-T7-2Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V5-T7-3Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V5-T7-4Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V5-T7-6Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . .V5-T7-7Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V5-T7-9Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V5-T7-1077.1Vacuum Contactors and StartersNEMA, Special Purpose and Mining RatingNEMA, Special Purpose and Mining RatingContentsDescription PageNEMA, Special Purpose and Mining RatingProduct Selection . . . . . . . . . . . . . . . . . . . . . . .V5-T7-3Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .V5-T7-4Replacement Parts . . . . . . . . . . . . . . . . . . . . . .V5-T7-6Technical Data and Specifications . . . . . . . . . .V5-T7-7Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . .V5-T7-9Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .V5-T7-10Product DescriptionVacuum contactors andstarters were designed forstarting and controlling three-phase, 50/60 Hz, AC motors.Each contact is enclosed in avacuum bottle to reduce andcontain contact arcing. Thisdesign offers excellentperformance for plugging andjogging applications.Application DescriptionThe vacuum contactors andstarters are offered in threeclassifications. They areNEMA® rated devices up to600 Vac, Special Purposerated devices up to 1500 Vacand Mining rated devicesrated up to 1500 Vac. Eachdevice is tested to differentstandards to serve its market.Typical applications includefull voltage control of three-phase squirrel cage motors,primary control of low voltagewound rotor motors andcircuit switching for lowvoltage capacitors for powerfactor improvement.A vacuum contactor isaffected by atmosphericpressure on the bellows ofthe vacuum bottles. Up to analtitude of 6600 feet, thecontactor is designed totolerate normal variations inbarometric pressure. If thecontactor is to be operatedabove 6600 feet above sealevel, consult your Eatonrepresentative.OperationThe contact structure of thevacuum break contactor islocated inside sealed ceramictubes that have beenevacuated of air. Any arcoccurring across the contactsupon opening is automaticallyextinguished because ionizedair is not available to sustainit—the arc breaks when thecurrent passes through zero.The arc typically does notservice beyond the first halfcycle once the contacts beginto separate. The large arcchutes normally associatedwith contactors of this sizeare not required. The ceramictube with the moving andstationary contacts is calleda vacuum interrupter orbottle. There is one bottle foreach pole on the contactor.A metal bellows (like a small,circular accordion) within thebottle allows the movingcontact to be closed andpulled open from the outsidewithout leaking air into thebottle. Both the bellow andthe metal-to-ceramic seals ofthese state-of-the-art bottleshave been refined to thepoint where the possibilityof loss of vacuum has beenvirtually eliminated.Features●Rugged, compactand lightweight●Quiet operation●Electrical and mechanicalinterlocks available●Long service lifeBenefits●Easy maintenancewith front removablecoil and auxiliaries●Eliminate extra surgesuppressors with thestandard low chopinterrupters●Plan your preventativemaintenance schedule byutilizing the contact wearindicator, standard on allvacuum bottlesStandards andCertifications●NEMA Devices●UL® Listed File #E1491,Guide Number NLDX●CSA® Approved●Special Purpose Devices●IEC 947-4-1●UL Listed File #E1491,Guide Number NLDX●CSA Approved77.1Vacuum Contactors and StartersNEMA, Special Purpose and Mining RatingProduct SelectionWhen Ordering Specify●Catalog number●Heater pack if ordering a starter, order in quantities of three ●Any required accessoriesNEMA Rated Vacuum Contactors and StartersSpecial Purpose Vacuum Contactors and StartersNotes1 Coils are rated for 50/60 Hz applications.2 Starters use Type B overload relay. Refer to Heater Coil Selection table on Page V5-T7-6. Starters do not include heater packs.NEMA Size Ampere Rating Motor Voltage Maximum Horsepower Rating MagnetCoil Voltage 1ContactorNon-Reversing Catalog Number Contactor ReversingCatalog Number StarterNon-Reversing Catalog Number 24135200230380460575405075100100110/120V201K4CJ V211K4CJ V200M4CJC 220/240V201K4CK V211K4CK V200M4CK 440/480V201K4CU V211K4CU V200M4CU 527020023038046057575100150200200110/120V201K5CJZ1V211K5CJZ1V200M5CJC 220/240V201K5CKZ1V211K5CKZ1V200M5CK 440/480V201K5CUZ1V211K5CUZ1V200M5CU 6540200230380460575150200300400400110/120V201K6CJZ1V211K6CJZ1V200M6CJC 220/240V201K6CKZ1V211K6CKZ1V200M6CK 440/480V201K6CUZ1—V200M6CUAmpere Rating Motor Voltage Maximum Horsepower Rating MagnetCoil Voltage 1Contactor Non-Reversing Catalog Number Contactor ReversingCatalog Number StarterNon-Reversing Catalog Number 2Starter ReversingCatalog Number 2160200230380460575800100015005060100125150200250400110/120V201KRCJ V211KRCJ ——220/240V201KRCK V211KRCK ——380/415V201KRCH V211KRCH ——440/480V201KRCUV211KRCU——32020023038046057580010001500100125200250300450500900110/120V201KTCJZ1V211KTCJZ1V200MTCJC V210MTCJC 220/240V201KTCKZ1V211KTCKZ1V200MTCK V210MTCK 380/415V201KTCHZ1V211KTCHZ1V200MTCH V210MTCH 440/480V201KTCUZ1V211KTCUZ1V200MTCUV210MTCU540 2002303804605751000150015020030040050010001250110/120V201KVCJZ1V211KVCJZ1V200MVCJ V210MVCJ 220/240V201KVCKZ1V211KVCKZ1V200MVCK V210MVCK 380/415V201KVCHZ1—V200MVCH —440/480V201KVCUZ1—V200MVCU —6102002303804605758001000150020020030045050080010001600110/120V201KZCJZ1V211KZCJZ1——220/240V201KZCKZ1V211KZCKZ1——380/415V201KZCHZ1———440/480V201KZCUZ1———Size 4 Vacuum Contactor160 A Vacuum Contactor77.1Vacuum Contactors and StartersNEMA, Special Purpose and Mining RatingMining Rated Vacuum Contactors and StartersAccessoriesLug Sizes●Size 4—12–4/0●NEMA Size 5 and 6 and 320 A, 540 A and 610 A—supplied without line or load lugs.Lug Kits—Consist of Six LugsField Modification KitsAuxiliary Electrical ContactsSize 4—Three Type J auxiliarycontacts may be mounted onthe top of Size 4 contactors toprovide six auxiliary, isolated600 V, 10 A contacts for usein control circuits.Sizes 5–6—Two Type Jauxiliary contacts may bemounted on each side of Size5 and6 contactors to providefour auxiliary, isolated 600V,10 A contacts for use incontrol circuits.Auxiliary Electrical Contacts Horizontal MechanicalInterlockNotes1Coils are rated for 50/60 Hz applications.2Used with Size 4 only. CC is coil clearing.AmpereRatingMotorVoltageMaximumHorsepowerRatingMagnetCoil Voltage 1ContactorNon-ReversingCatalog Number16020023038046057580015005060100125150200400110/120VM160CJ220/240VM160CK440/480VM160CU3202002303804605758001500100125200250300450900110/120VM320CJZ1220/240VM320CKZ1440/480VM320CUZ161020023038046057580015001502003004005008001600110/120VM610CJZ1220/240VM610CKZ1440/480VM610CUZ1Size Description Catalog Number5 and 320 A1/0–500 kcmil C325KAL86, 540 A and 610 A1/0–500 kcmil double barrel C325KAL9610 A1/0–600 kcmil double barrel80-19825-2160 A Mining VacuumContactorContactArrangement Catalog Number1NO, 1NC J111NO, 1NC CC 2J1CV2NO J202NC J02Size Catalog Number4180C113G045180C113G165180C113G1777.1Vacuum Contactors and StartersNEMA, Special Purpose and Mining RatingAEGIS Powerline FiltersIdeal for applications that utilize 120 Vac or 240 Vac control voltage and have the likelihood of harmonics or noise being present on the control signal. These are stand-alone devices, not mounted to the contactor.AEGIS Powerline Filters Protect Against the Full Spectrum of T ransient DisturbancesAEGIS filters the entire sine wave and is effective against both frequently occurring low energy and occasional high energy transients. Highenergy transients can create immediate damage, while low energy transients causecoil failure over time.Catalog Numbering SystemAEGIS-HW (Hard Wire Application)230 V applies to 220 V and 240 V applications.AEGIS Powerline FiltersNotes1Model tested at 15 A UL/CSA = 16 A CE.2See AEGIS Powerline Filters in Volume 3—Power Distribution and Control Assemblies , CA08100004E, Tab 2.AGSHW CH XOptionsS =StandardC =Form C contact for remote monitorVoltage Code 120N 230LCurrent Capacity 03051015 120Catalog Number 2Catalog Number 2AGSHWCH120N03XC AGSHWCH230L03XC AGSHWCH120N03XS AGSHWCH230L03XS AGSHWCH120N05XC AGSHWCH230L05XC AGSHWCH120N05XSAGSHWCH230L05XS77.1Vacuum Contactors and StartersNEMA, Special Purpose and Mining RatingHeater CoilsHeater Coils for T ype B Overload Relay 1Replacement PartsVacuum Contactor—Replacement CoilsNotes1Motor full load current in amperes for use with three heaters only.2Three are required per overload relay.3125 Vdc can be directly applied to the Size 5 and 6 coil rated for 120 Vac/60 Hz (cannot be applied to Size 4).4250 Vdc can be directly applied to the Size 5 and 6 coil rated for 240 Vac/60 Hz (cannot be applied to Size 4).Open StarterHeaterCatalog Number 2Open StarterHeaterCatalog Number 2 Ambient CompensatedOverload RelayAmbient CompensatedOverload RelaySize 4 and 160 A Size 5 and 320 A with 300/5 Current T ransformers 12.8–14.1FH68107–117FH2314.2–15.5FH69118–129FH2415.6–17.1FH70130–141FH2517.2–18.9FH71142–155FH2619.0–20.8FH72156–170FH2720.9–22.9FH73171–187FH2823.0–25.2FH74188–205FH2925.3–27.8FH75206–224FH3027.9–30.6FH76225–244FH3130.7–33.5FH77245–263FH3233.6–37.5FH78264–292FH3337.6–41.5FH79293–318FH3441.6–46.3FH80319–350FH3546.4–50FH81Size 6 and 540 A with 600/5 Current T ransformers 51–55FH82236–259FH2456–61FH83260–283FH2562–66FH84284–310FH2667–73FH85311–340FH2774–78FH86341–374FH2879–84FH87375–411FH2985–92FH88412–448FH3093–101FH89449–489FH31102–110FH90490–527FH32111–122FH91528–585FH33123–129FH92586–600FH34130–133FH93—FH94Description Suffix Part NumberSize 4110/120 Vac, 50/60 Hz J9085A57G01220/240 Vac, 50/60 Hz K9085A57G02380/415 Vac, 50/60 Hz H ID89221G07440/480 Vac, 50/60 Hz U9085A57G03Size 5110/120 Vac, 50/60 Hz J7874A09G01 3220/240 Vac, 50/60 Hz K7874A09G04 4380/415 Vac, 50/60 Hz H7874A09G10440/480 Vac, 50/60 Hz U7874A09G05Size 6110/120 Vac, 50/60 Hz J7874A24G01 3220/240 Vac, 50/60 Hz K7874A24G02 4380/415 Vac, 50/60 Hz H7874A24G07440/480 Vac, 50/60 Hz U7874A24G0377.1Vacuum Contactors and StartersNEMA, Special Purpose and Mining RatingTechnical Data and SpecificationsNEMA, Special Purpose and Mining RatingNote1For transformers having inrush currents of not more than 20 times the rated full load current.Description NEMASpecial Purpose Size 4V201K4_Size 5V201K5_Size 6V201K6_160 A V201KR_320 A V201KT_540 A V201KV_610 A V201KZ_Poles3333333Maximum voltage rating 600 V 600 V 600 V 1500 V 1500 V 1500 V 1500 V Ampere rating 135 A 270 A 540 A 160 A 320 A 540 A 610 A Frequency, Hz50/6050/6050/6050/6050/6050/6050/60Maximum closing current 1600 A 3000 A 6000 A 1600 A 3000 A 6000 A 6000 A Maximum interrupting current 1600 A3000 A6000 A1600 A3000 A6000 A6000 AShort time current 1 second 2400 A rms 4500 A rms 9000 A rms 2400 A rms 4500 A rms 9000 A rms 9000 A rms 2 second 1600 A rms 3000 A rms 6000 A rms 1600 A rms 3000 A rms 6000 A rms 6000 A rms Dielectric strength2200 Vac 5375 Vac 5375 Vac 2200 Vac 5375 Vac 5375 Vac 5375 Vac Maximum allowable interrupting 1200/hr ——1200/hr ———Impulse voltage (1 x 40 ms)15 kV15 kV15 kV15 kV15 kV15 kV15 kVMaximum motor hp at:200 V 40 hp 75 hp 150 hp 50 hp 100 hp 150 hp 200 hp 230 V 50 hp 100 hp 200 hp 60 hp 125 hp 200 hp 200 hp 380 V 75 hp 150 hp 300 hp 100 hp 200 hp 300 hp 300 hp 460 V 100 hp 200 hp 400 hp 125 hp 250 hp 400 hp 450 hp 575 V 100 hp 200 hp 400 hp 150 hp 300 hp 500 hp 500 hp 800 V ———200 hp 450 hp —800 hp 1000 V ———250 hp 500 hp 1000 hp 1000 hp 1500 V———400 hp900 hp1250 hp1600 hpThree-phase capacitive switching (kVAR):230 V 0 kvar 80 kvar 160 kvar 50 kvar 80 kvar 160 kvar 176 kvar 460 V 80 kvar 160 kvar 320 kvar 100 kvar 160 kvar 320 kvar 356 kvar 600 V 100 kvar 200 kvar 400 kvar 125 kvar 200 kvar 400 kvar 400 kvar 1500 V———205 kvar500 kvar—1000 kvarTransformer switching (kVA) 1single-phase, two-pole:120 V 6.8 kVA 14 kVA 27 kVA 8 kVA 14 kVA 27 kVA 27 kVA 240 V 14 kVA 27 kVA 54 kVA 16 kVA 27 kVA 54 kVA 54 kVA 480 V 27 kVA 54 kVA 108 kVA 32 kVA 54 kVA 108 kVA 108 kVA 600 V34 kVA68 kVA135 kVA40 kVA68 kVA135 kVA135 kVAThree-phase, three-pole:240 V 23 kVA 47 kVA 94 kVA 27 kVA 47 kVA 94 kVA 94 kVA 480 V 47 kVA 94 kVA 188 kVA 55 kVA 94 kVA 188 kVA 188 kVA 600 V59 kVA117 kVA234 kVA70 kVA117 kVA234 kVA234 kVA77.1Vacuum Contactors and StartersNEMA, Special Purpose and Mining RatingElectrical Characteristics—NEMA and Special Purpose T ypesElectrical Characteristics Coil Data (AC Supply Rectified)DescriptionSize4 (160 A)5 (320 A)6 (540 A and 610 A)DC coil data—burden:(AC supply rectified)Open VA300 VA500 VA1450 VAClosed VA30 VA25 VA32 VAClosed watts 6 W20 W30 WPick-up volts70% of rated coil volts70% of rated coil volts70% of rated coil volts Drop-out volts50% of rated coil volts50% of rated coil volts50% of rated coil volts Pick-up time in Hz 1.5–2 Hz 1.5–2 Hz 1.5–2 HzDrop-out time in Hz6–6.15 Hz6–6.15 Hz6–6.15 HzMaximum voltage rating600 V600 V600 VMaximum closing current1600 A3000 A6000 AMaximum interrupting current1600 A3000 A6000 AShort time current:1 second2400 A rms4500 A rms9000 A rms2 second1600 A rms3000 A rms6000 A rmsBurden Size 4 (160 A)Size 5 (320 A)Size 6 (540 A and 610 A) Inrush VA3006001700Sealed VA302028Sealed watts62028Pick-up volts70% of rated coil volts70% of rated coil volts70% of rated coil volts Drop-out volts50% of rated coil volts50% of rated coil volts50% of rated coil volts Pick-up time in Hz 1.5–2 1.5–2 1.5–2Drop-out time in Hz6–7.56–6.156–6.1577.1Vacuum Contactors and StartersNEMA, Special Purpose and Mining RatingWiring DiagramsSize 4 ContactorSizes 5 and 6 StarterL63 Coil Aux. Contact77.1Vacuum Contactors and StartersNEMA, Special Purpose and Mining RatingDimensionsApproximate Dimensions in Inches (mm)Open Type Contactors and Starters—Size 4 and 160 ASize and 160 A Non-Reversing ContactorSize 4 and 160 A Reversing ContactorSize 4 Non-Reversing StarterRear View — Drilling Plan Front View Side View1.44 (36.6).1) Dia.Front View Shownwithout Cover Plateand OvertravelGauge..8)Rear View — Drilling Plan Front View Side Vew.1) Dia.Rear View — Drilling Plan Front View Side VewVolume 5—Motor Control and Protection CA08100006E—November V5-T7-117NEMA, Special Purpose and Mining RatingApproximate Dimensions in Inches (mm)Open Type Contactors and Starters—Size 4 and 160 A, continued Size 4 Reversing StarterOpen Type Contactors and Starters—Size 5 and 320 A Size 5 and 320 A Non-Reversing ContactorSize 5 and 320 A Reversing Contactor.14) Dia.Rear View — Drilling PlanFront ViewSide VewDrilling Plan — Rear View 7Are 3/8-16 T Line T 3/8-16 Line T 3 Places.9) Interlocks Contactor. (When Used)B – Coil T erminals7Approximate Dimensions in Inches (mm)Open Type Contactors and Starters—Size 5 and 320 A, continuedSize 5 and 320 Non-Reversing Starter320 Reversing Starter“A” Dim.A – Two Dual CircuitInterlocksLocatedon Both Sides ofStarter.(WhenUsed)B – Coil T erminalsLocated on BothSides of Starter.3 PlacesDia..9)SlotSlot7 (177.8)NormalT rippedType B RelayMax. Dim to ResetType A RelayMax. Dim to ResetType B RelayAutomatic Reset6.75(171.5)6.73(170.9)6.61(167.9)7 (177.8)Normalor T rippedV5-T7-12Volume 5—Motor Control and Protection CA08100006E—November Volume 5—Motor Control and Protection CA08100006E—November V5-T7-137NEMA, Special Purpose and Mining RatingApproximate Dimensions in Inches (mm)Open Type Contactors and Starters—Size 6, 540 A and 610 A Size 6, 540 A and 610 A Non-Reversing ContactorSize 6, 540 A and 610 A Reversing ContactorSlot LoadA—Two Dual Circuit InterlocksLocated on Both Sides of Contactor. (When Used)B—Coil T erminals Located onBoth Sides of Contactor.Rear View—Drilling PlanFront View Side VewFront View Side View7Approximate Dimensions in Inches (mm)Open Type Contactors and Starters—Size 6, 540 A and 610 A, continuedSize 6 and 540 A Non-Reversing Starter540 A Reversing StarterSlotRear View—Drilling PlanA—Two Dual CircuitInterlocks Located onBoth Sides of Starter.(When Used)B—Coil T erminals Locatedon Both Sides of Starter.Front ViewSide ViewFront ViewSide ViewV5-T7-14Volume 5—Motor Control and Protection CA08100006E—November 。
CMF商用电源ACP3225型号电源共模滤波器产品说明书
Common mode filters For power line ACP seriesACP3225 typeFEATURESimpedance.atible with high-density p ortable devices, which are always being made smaller and lighter, because the height has been reduced.APPLICATIONPART NUMBER CONSTRUCTIONCHARACTERISTICS SPECIFICATION TABLE*Temperature derating was considered for the rated current.Measurement equipmentEquivalent measurement equipment may be used.ACP3225-102-2PACP3225-501-2PACP3225-102-2P-T000Series nameL×W×H dimensions Impedance Number of linesPackaging styleInternal code3.2×2.5×1.9 mm(Ω) at 100MHzCommon mode impedance[at 100MHz]DC resistanceRated current *Rated voltageInsulation resistance Part No.(Ω)Tolerance (m Ω)typ.(m Ω)max.(A)max.(V)max.(M Ω)min.1000±25%50100 1.56010ACP3225-102-2P-T000500±25%4010026010ACP3225-501-2P-T000Measurement item Product No.ManufacturerCommon mode impedance 4991A Keysight T echnologies DC resistance 4338A Keysight T echnologies Insulation resistance 4339AKeysight TechnologiesIMPEDANCE VS. FREQUENCY CHARACTERISTICSMeasurement equipmentProduct No.Manufacturer4991A Keysight T echnologiesEquivalent measurement equipment may be used.SHAPE & DIMENSIONSRECOMMENDED LAND PATTERNCIRCUIT DIAGRAMRECOMMENDED REFLOW PROFILEPACKAGING STYLETEMPERATURE RANGE, INDIVIDUAL WEIGHT*For actual use, use within the temperature derating range shown in page 1/4 of this catalog.**The storage temperature range is for after the assembly.Dimensions in mmDimensions in mmT ype A B KACP3225(2.9)(3.6)(2.35)Package quantity1000 pcs/reelOperating temperature range*Storagetemperature range**Individualweight–40 to +85 °C–40 to +85 °C60 mgDimensions in mmREMINDERS FOR USING THESE PRODUCTSBefore using these products, be sure to request the delivery specifications.SAFETY REMINDERSPlease pay sufficient attention to the warnings for safe designing when using this products.The storage period is within 6 months. Be sure to follow the storage conditions (temperature: 5 to 40°C, humidity: 10 to 75% RH or less).If the storage period elapses, the soldering of the terminal electrodes may deteriorate.Do not use or store in locations where there are conditions such as gas corrosion (salt, acid, alkali, etc.).Before soldering, be sure to preheat components.The preheating temperature should be set so that the temperature difference between the solder temperature and chip temperature does not exceed 150°C.Soldering corrections after mounting should be within the range of the conditions determined in the specifications.If overheated, a short circuit, performance deterioration, or lifespan shortening may occur.When embedding a printed circuit board where a chip is mounted to a set, be sure that residual stress is not given to the chip due to the overall distortion of the printed circuit board and partial distortion such as at screw tightening portions.Self heating (temperature increase) occurs when the power is turned ON, so the tolerance should be sufficient for the set thermal design.Carefully lay out the coil for the circuit board design of the non-magnetic shield type.A malfunction may occur due to magnetic interference.Use a wrist band to discharge static electricity in your body through the grounding wire.Do not expose the products to magnets or magnetic fields.Do not use for a purpose outside of the contents regulated in the delivery specifications.The products listed on this catalog are intended for use in general electronic equipment (AV equipment, telecommunications equip-ment, home appliances, amusement equipment, computer equipment, personal equipment, office equipment, measurement equip-ment, industrial robots) under a normal operation and use condition.The products are not designed or warranted to meet the requirements of the applications listed below, whose performance and/or qual-ity require a more stringent level of safety or reliability, or whose failure, malfunction or trouble could cause serious damage to society,person or property.If you intend to use the products in the applications listed below or if you have special requirements exceeding the range or conditions set forth in the each catalog, please contact us.(1) Aerospace/aviation equipment(2) T ransportation equipment (cars, electric trains, ships, etc.)(3) Medical equipment(4) Power-generation control equipment (5) Atomic energy-related equipment (6) Seabed equipment(7) T ransportation control equipment(8) Public information-processing equipment (9) Military equipment(10) Electric heating apparatus, burning equipment (11) Disaster prevention/crime prevention equipment(12) Safety equipment(13) Other applications that are not considered general-purposeapplicationsWhen designing your equipment even for general-purpose applications, you are kindly requested to take into consideration securing pro-tection circuit/device or providing backup circuits in your equipment.REMINDERS。
电源22-29V 0.6A恒流 规格书1
规格书SPECIFICATION FOR APPROVAL 客户名称(CUSTOMER):客户料号(PART NO.):客户品名(DESCRIPTION):品名(DESCRIPTION):22-29V0.6A日期(DATE):2012-02-16承认签章后请回传Please return to us one copy of“SPECIFICATION FOR APPROVAL”with your approved signatures承认书APPROVED SIGNATURES客户承认(CUSTOMER APPROVAL)公司承认(APPROVAL)工程师ENGINEER审核CHECKEDBY批准APPROVAL BY工程师ENGINEER审核CHECKEDBY批准APPROVALBY盖章签署(CHOP&SIGNATU RES)盖章签署(CHOP&SIGNATU RES)日期(DATE)日期(DATE)目录变更履历表 (3)1.导言Introduction (4)1.1电源概况Power Supply Overview (4)1.2支持文件Applicable Documents (4)2电气规格Electrical Specification (5)2.1AC输入AC Input (5)2.1.1输入电压Input Voltage (5)2.1.2输入频率Input Frequency (5)2.1.3冲击电流Inrush Current (5)2.1.4最大输入电流Input Current Limiting (5)2.1.5效率Efficiency (5)2.1.6功率因数Power factor (5)2.2输出规格Output Specification (5)2.2.1电压调整率DC Voltage Regulation (5)2.2.2输出电流DC Output Current (6)2.2.3输出纹波与噪声Output Ripple and Noise (6)2.2.4输出动态负载响应定电流模式Output Dynamic Load Response CC model (6)2.2.5电压过冲Overshoot at turn-on/turn-off (6)2.3保护功能Protection Function (7)2.3.1短路保护Short Circuit Protection (7)2.3.2过流保护Over Current Protection (7)2.4时序特性Timing (7)2.4.1保持时间Hold up Time (7)2.4.2启动时间Start up Time (7)3.环境要求Environment Requirement (7)3.1温度Temperature (7)3.2湿度Humidity (7)3.3海拔高度Altitude (7)4.可靠性Reliability (8)4.1平均无故障间隔时间MTBF(MIL-HDBK-217F) (8)4.2老化寿命测试Burn-in and Life test (8)5.产品安规要求Product Safety Requirement (8)5.1标准Standard (8)5.2泄露电流Leakage Current (8)5.3绝缘阻抗Insulation Resistance (8)5.4绝缘强度Dielectric Strength Testing (8)6.结构尺寸Mechanical Dimensions(单位:mm Unit:mm) (8)6.1标贴Label (8)6.2结构尺寸Mechanical Dimensions (9)7声明Statement (9)变更履历表Revision History承认书版本Spec.Edition发行日期Release Date修改内容Modified content产品版本Product EditionRev:A002012-02-16初版Initial1.1电源概况Power Supply Overview本产品效率高,可靠性高等特点,具有短路保护,过流保护等保护功能。
艾顿 9PX 3000i RT3U HotSwap BS 电源说明书
Eaton 9PX3000IRTBPBEaton 9PX UPS HotSwap BS, 3000 VA, 3000 W, Input: C20, Outputs: (3) BS, (1) C19, Rack/tower, 3UGeneral specificationsEaton 9PX UPS 9PX3000IRTBPB Eaton 9PX 3000i RT3U HotSwap BS 74317208158248.5 cm 13 cm 44 cm 27.41 kg 3 year on electronics, 2 year on batteryCE Marked CSA 22.2 TUVCISPR22 Class B cULus Listed FCC part 15 Class BENERGY STAR certified IEC/EN 62040-1 CEIEC/EN 62040-2 EAC UL 1778Product Name Catalog Number Model CodeUPCProduct Length/Depth Product Height Product Width Product Weight WarrantyCompliances CertificationsView runtime graph Hot-swappable internal batteries and extended battery modules (EBMs)612 V / 9 Ah Sealed, lead-acidYes(3) BS, (1) C19Online/Double-conversion 3000 W 3000 VA Sine wave 230V1230V default (200/208/220/230/240V)200/208/220/230/240 V +/- 1%350/60 Hz 1C201.8m230V default (200/208/220/230/240V)176-276 V (100-276 V with derating)Runtime graph Battery management Battery replacementBattery quantity Battery rating Battery type Extended battery capability Receptacle TopologyWattage VA rating Output waveform Voltage Output power factor Output nominal voltageOutput voltage rangeVoltage distortion output (linear load) - max Output frequency Feed type Input connection Input cord length Input nominal voltageInput voltage rangeCommunicationABM & Temperature compensated charging method (user selectable)Automatic battery test Deep discharge protection Automatic recognition of external battery units USB port (HID compliant)Serial port (RS232)Mini terminal block for remote On/Off Mini-terminal block for remote power off Mini-terminal block for output relayDry contacts (3 outputs, 150/60 Hz40-70 Hz>.99One slot for optional communication card NoNoEaton Intelligent Power Manager, Eaton Intelligent Power Protector Multilingual graphical LCD display OtherYes3000 m Online: 614<40 dB at 1 meter 0-96% non-condensing 0° to 40°C (32° to 104°F)Nominal frequency Input frequency range Input power factor Expansion slotsEthernet interfaceIncludes network card Software compatibilityUser interfaceType of interface Potential free switch contact Altitude BTU Rating Noise level Relative humidity Temperature range Special featuresinput, optocoupler, DB9)Double conversion topology Constantly monitors power conditions and regulates voltage and frequency First UPS in its class to provide Unity power factor (VA=W)Energy Star qualified, provides the highest efficiency level to reduce energy and cooling costs Internal bypass allows service continuity in case of UPS faultNext-generation graphical LCD displayCompatible with Virtual environments (VMware, Hyper-V, Citrix Xen, Redhat)Meter energy consumption (down to the managed outletRack/tower3U482.6 mm (19 inch) device Yes9411YesYes Eaton UPS and battery servicesEaton UPS Services Quick Guide 2021EU declaration of conformity Eaton 9PX UPSEaton 9PX 1-3 kVA UPS and 9PX EBM 48V and 72V - Installation and user manualEaton 9PX 1-3 kVA UPS - Quick Start GuideEaton Bypass Power Module (BPM) user guideEaton Specification Sheet - 9PX3000IRTBPBEaton 9PX 1000-3000W UPS - DatasheetForm factorRack size Construction type Rack mounting kit Efficiency Package contentsPhase (input) Phase (output) Internal bypass Hot swap power BrochuresCompliance information Manuals and user guidesSpecifications and datasheets Technical data sheetsgroups)Hot swappable batteries Advanced Battery Management (ABM) technology to increase battery lifetimeLong backup time with up to 4 optional EBMUPSInput cableMaintenance Bypass(2) IEC-IEC output cables USB cableSerial cable(2) brackets for 19’ mounting (2) Rack-mounting kit(2) Supports for tower mountingCable locking system Safety instructions Quickstart guideEaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. All rights reserved. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmediaYesAuto shutdown function。
ControlLogix 1756 电源供应说明书
Technical Data1756 ControlLogix Power Supplies SpecificationsStandard Power Supplies Catalog Numbers 1756-PA72, 1756-PA75, 1756-PB72, 1756-PB75, 1756-PC75, 1756-PH75Standard Slim Power Supplies Catalog Numbers 1756-PA50, 1756-PB50ControlLogix-XT Power Supplies Catalog Numbers 1756-PAXT, 1756-PBXTControlLogix-XT Slim Power Supplies Catalog Numbers 1756-PA30XT, 1756-PB30XTRedundant Power Supplies Catalog Numbers 1756-PA75R, 1756-PB75RRedundant Power Supplies Chassis Adapter Catalog Number 1756-PSCA2ControlLogix-XT Redundant Power Supplies Catalog Numbers 1756-PAXTR, 1756-PBXTRControlLogix-XT Redundant Power Supplies Chassis Adapter Catalog Number 1756-PSCA2XTRedundant Power Supply Power Cable Catalog Numbers 1756-CPR2, 1756-CPR2D, 1756-CPR2UControlLogix® power supplies are used with the 1756 chassis to provide 1.2V, 3.3V, 5V, and 24V DC power directly to the chassis backplane. Standard, Slim, ControlLogix-XT™, and redundant power supplies are available.Summary of ChangesThis manual contains changes to the 1756-PBXT ControlLogix-XT power supply and 1756-PBXTR ControlLogix-XT redundant power supply technical specifications.2Rockwell Automation Publication 1756-TD005G-EN-E - June 20171756 ControlLogix Power Supplies SpecificationsStandard AC Power SuppliesMounting DimensionsTechnical Specifications - Standard AC Power SuppliesDimensions are in cm (in.).1756-PA72 and 1756-PA75(5.51)1756-PA501756 ControlLogix Power Supplies Specifications Technical Specifications - Standard AC Power Supplies(1)UL certification for 120/240V AC, 50/60 Hz nominal. Rockwell Automation specified 85…265V AC, 47…63 Hz.(2)The hold up time is the time between input voltage removal and DC power failure.(3)The combination of all output power (5.1V backplane, 24V backplane, 3.3V backplane, and 1.2V backplane) cannot exceed 60 W @ 50 °C (122 °F) maximum temperature.(4)The combination of all output power (5.1V backplane, 24V backplane, 3.3V backplane, and 1.2V backplane) cannot exceed 50 W @ 60 °C (140 °F) maximum temperature.(5)Use this conductor category information to plan conductor routing as described in the system level installation manual. See the Industrial Automation Wiring and Grounding Guidelines,publication 1770-4.1.(6)The combination of all output power (5.1V backplane, 24V backplane, 3.3V backplane, and 1.2V backplane) cannot exceed 75 W.Environmental Specifications - Standard AC Power Supplies(1)Series C chassis have a maximum nonoperating shock value of 30 g. If you select a Series C chassis for use with your power supply, you are limited to a maximum nonoperating shock value of 30 g.Rockwell Automation Publication 1756-TD005G-EN-E - June 201731756 ControlLogix Power Supplies SpecificationsCertifications - Standard AC Power Supplies(1)See the Product Certification link at for Declarations of Conformity, Certificates, and other certification details.4Rockwell Automation Publication 1756-TD005G-EN-E - June 2017Rockwell Automation Publication 1756-TD005G-EN-E - June 201751756 ControlLogix Power Supplies SpecificationsStandard DC Power SuppliesMounting DimensionsTechnical Specifications - Standard DC Power SuppliesDimensions are in cm (in.).(5.51)1756-PB501756-PB72, 1756-PB75, 1756-PC75, and 1756-PH751756 ControlLogix Power Supplies SpecificationsTechnical Specifications - Standard DC Power Supplies(1)The hold up time is the time between input voltage removal and DC power failure.(2)UL certification for 24V DC nominal. Rockwell Automation specified 18…32V DC.(3)Use this conductor category information to plan conductor routing as described in the system level installation manual. See the Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.(4)The combination of all output power (5.1V backplane, 24V backplane, 3.3V backplane, and 1.2V backplane) cannot exceed 75 W.(5)UL Certification for 48V DC nominal. Rockwell Automation specified 30…60V DC.(6)UL certification for 125V DC nominal. Rockwell Automation specified 90…143V DC.Environmental Specifications - Standard DC Power Supplies6Rockwell Automation Publication 1756-TD005G-EN-E - June 20171756 ControlLogix Power Supplies Specifications Environmental Specifications - Standard DC Power Supplies(1)Series C chassis have a maximum nonoperating shock value of 30 g. If you select a Series C chassis for use with your power supply, you are limited to a maximum nonoperating shock value of 30 g.(2)Short interruption test verifies ride through. The supply remains fully functional under this condition.(3)Long interruption test verifies that repetitive inrush surge currents do not create any unsafe conditions. The supply fully shuts down and starts up in this test.Certifications - Standard DC Power Supplies(1)When marked. See the Product Certification link at for Declarations of Conformity, Certificates, and other certification details.Rockwell Automation Publication 1756-TD005G-EN-E - June 201778Rockwell Automation Publication 1756-TD005G-EN-E - June 20171756 ControlLogix Power Supplies Specifications1756 ControlLogix-XT Power SuppliesThe ControlLogix-XT products include control and communication system components that, when used with FLEX I/O-XT™ products, provide a complete control system solution that you can use in environments where temperatures range from -20…+70 ︒C (-4…+158 ︒F).When used independently, the ControlLogix-XT system can withstand environments where the temperature ranges from -25…+70 ︒C (-13…+158 ︒F).Mounting DimensionsTechnical Specifications - ControlLogix-XT Power SuppliesDimensions are in cm (in.).14.0 (5.51)1756-PAXT and 1756-PBXT1756-PA30XT and 1756-PB30XT1756 ControlLogix Power Supplies Specifications Technical Specifications - ControlLogix-XT Power Supplies(1)UL certification for 120/240V AC, 50/60 Hz nominal. Rockwell Automation specified 85…265V AC, 47…63 Hz.(2)Use this conductor category information to plan conductor routing as described in the system level installation manual. See the Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.(3)UL certification for 24V DC nominal. Rockwell Automation specified 18…32V DC.Environmental Specifications - ControlLogix-XT Power SuppliesRockwell Automation Publication 1756-TD005G-EN-E - June 201791756 ControlLogix Power Supplies SpecificationsEnvironmental Specifications - ControlLogix-XT Power Supplies(1)Series C chassis have a maximum nonoperating shock value of 30 g. If you select a Series C chassis for use with your power supply, you are limited to a maximum nonoperating shock value of 30 g.(2)Short interruption test verifies ride through. The supply remains fully functional under this condition.(3)Long interruption test verifies that repetitive inrush surge currents do not create any unsafe conditions. The supply fully shuts down and starts up in this test.Certifications - ControlLogix-XT Power Supplies(1)When marked. See the Product Certification link at for Declarations of Conformity, Certificates, and other certification details.10Rockwell Automation Publication 1756-TD005G-EN-E - June 2017Redundant Power SuppliesT o build a redundant power supply system, you need the following.System Configuration RecommendationsW e recommend that you use one of these methods to configure your redundant power supply system.(1)Cable bend radius is 12.7 cm (5.0 in.).(2)Requires 10.16 cm (4.0 in.) of clearance next to the chassis adapter.(3)The 1756-PSCA2 or 1756-PSCA-2XT chassis adapter is a passive device. The adapter funnels power from the redundant power supplies to the single power connectoron the ControlLogix series B chassis backplane.(4)Optional user-provided annunciator wiring can be connected to the solid-state relay for status and troubleshooting.Recommended Configurations for a System That Uses One ChassisRecommended Configurations for a System That Uses Two ChassisMounting DimensionsRedundant Power Supply FeaturesThe redundant power supplies offer the same features as the standard power supplies, and the following:•Redundant operation•Automatic chassis load sharing between the redundant power supplies •Status indicators for visual operating status of the pair•Solid-state relay for system recognition of supply status when wired to an input module•The ControlLogix redundant power supply system is designed to account for operational anomalies in only the power supply (the chassis adapter and power supply cables are excluded)Technical Specifications - ControlLogix Redundant Power Supplies1.1 (0.433)0.55 Top Mounting Hole DiameterBottom Mounting Hole Diameter7.0 Dimensions are in cm (in.).Technical Specifications - ControlLogix Redundant Power Supplies(1)UL certification for 120/240V AC, 50/60 Hz nominal. Rockwell Automation specified 85…265V AC, 47…63 Hz.(2)UL certification for 24V DC nominal. Rockwell Automation specified 18…32V DC.(3)The hold up time is the time between input voltage removal and DC power failure.(4)Use this conductor category information to plan conductor routing. See the Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. Environmental Specifications - Redundant Power Supplies(1)Short interruption test verifies ride through. The supply remains fully functional under this condition.(2)Long interruption test verifies that repetitive inrush surge currents do not create any unsafe conditions. The supply fully shuts down and starts up in this test.Certifications - Redundant Power Supplies(1)When marked. See the Product Certification link at for Declarations of Conformity, Certificates, and other certification details.Technical Specifications - ControlLogix-XT Redundant Power SuppliesEnvironmental Specifications - Redundant Power SuppliesTechnical Specifications - ControlLogix-XT Redundant Power Supplies(1)UL certification for 120/240V AC, 50/60 Hz nominal. Rockwell Automation specified 85…265V AC, 47…63 Hz.(2)Use this conductor category information to plan conductor routing. See Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. Environmental Specifications - XT Redundant Power SuppliesEnvironmental Specifications - XT Redundant Power Supplies(1)Short interruption test verifies ride through. The supply remains fully functional under this condition.(2)Long interruption test verifies that repetitive inrush surge currents do not create any unsafe conditions. The supply fully shuts down and starts up in this test. Certifications - XT Redundant Power Supplies(1)When marked. See the Product Certification link at for Declarations of Conformity, Certificates, and other certification details.Redundant Power Supply Chassis AdapterTechnical Specifications - Redundant Power Supplies Chassis Adapter(1)Use this conductor category information to plan conductor routing. See the Industrial Automation Wiring and Grounding Guidelines, publication1770-4.1.Environmental Specifications - Redundant Power Supplies Chassis AdapterPower Load and Transformer SizingThe following graphs show the input power requirements for the power supplies, given the power that they are providing to the modules in the chassis.Follow these steps to determine the power requirements for your chassis.1.Calculate the Backplane Power Load by adding the power draw (in watts) for all planned modules.For module power draws, refer to the module specification tables in the ControlLogix Selection Guide, publication 1756-SG001.2.Locate the Backplane Power Load on the vertical (y) axis of the graph and determine the corresponding Real Power (input-power) rating on the horizontal (x) axis.The Real Power value is the amount of power that is consumed by the power supply.Certifications - Redundant Power Supplies Chassis Adapter(1)When marked. See the Product Certification link at for Declarations of Conformity, Certificates, and other certification details.Standard Power Supply Power Requirements7142128354942567142128354275604530150756045301507560453015042352821147056494235282114701756-PA72/C, 1756-PA75/B (AC)1756-PB72/C, 1756-PB75/B (DC)Real Power (Watts)Backplane Power Load (Watts)Backplane Power Load (Watts)1756-PH75/B, 1756-PC75/B (DC)Backplane Power Load (Watts)Real Power (Watts)Backplane PowerLoad (Watts)1756-PBXT (DC)1756-PAXT (AC)Backplane Power Load (Watts)Real Power (Watts)75604530150756045301501756-PA75R/A (AC)Backplane Power Load (Watts)Backplane Power Load (Watts)1756-PB75R/A (DC)Apparent Power (Watts) = Transformer Load (VA) = Real Power (Watts)1756-PAXTR (AC)Real Power (Watts)Backplane Power Load (Watts)B a c k p l a n e P o w e r L o a d (W a t t s )Real Power (Watts)Real Power (Watts)Real Power (Watts)Real Power (Watts)Real Power (Watts)Slim Power Supply Power Requirements1756-PA50 @ 50 °C (AC)Backplane Power Load (Watts)Real Power (Watts)Apparent Power (Watts) = Transformer Load (VA) = Real Power (Watts)5040302010 0605040302010 01756-PA50 @ 60 °C (AC)Backplane Power Load (Watts)Real Power (Watts)5040302010 0601756-PB50 @ 50 °C (DC)Backplane Power Load (Watts)Real Power (Watts)50403020101756-PB50 @ 60 °C (DC)Backplane Power Load (Watts)Real Power (Watts)25201510 5 0301756-PA30XT (AC)Backplane Power Load (Watts)Real Power (Watts)1756-PB30XT (DC)Backplane Power Load (Watts)Real Power (Watts)20 10301756 ControlLogix Power Supplies SpecificationsAdditional ResourcesThese documents contain additional information concerning related products from Rockwell Automation.Y ou can view or download publications at /literature/. T o order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative.Rockwell Automation Publication 1756-TD005G-EN-E - June 2017211756 ControlLogix Power Supplies SpecificationsNotes:22Rockwell Automation Publication 1756-TD005G-EN-E - June 20171756 ControlLogix Power Supplies Specifications Notes:Rockwell Automation Publication 1756-TD005G-EN-E - June 201723Rockwell Automation maintains current product environmental information on its website at /rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page.Allen-Bradley, ControlLogix, ControlLogix-XT, FLEX I/O-XT, LISTEN. THINK. SOLVE, Rockwell Automation, and Rockwell Software are trademarks of Rockwell Automation, Inc.Trademarks not belonging to Rockwell Automation are property of their respective companies.Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, T el: +90 (216) 5698400Publication 1756-TD005G-EN-E - June 2017Supersedes Publication 1756-TD005F-EN-E - May 2016Copyright © 2017 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
Part No.Features VIN VOUT Accu IQ IOUT(Max)Package应用领域BL1117Bipolar,Low dropoutvoltage Max 18V 1.2,1.8,2.5,3.3,5V&ADJ±1%/±1.5%4mA1A SOT223TO252主板、LCD、机顶盒、电话机、DVD、数码相框、移动硬盘等BL1085Bipolar,Low dropoutvoltage Max 18V 1.8,2.5,3.3,5V&ADJ±2%4mA3A TO252TO263LCD、主板、车载等BL1084Bipolar,Low dropoutvoltage Max 18V 1.8,2.5,3.3,5V&ADJ±2%5mA5A TO252TO263LCD、光端机、车载等Part No.Features VIN VOUT Accu IQ IOUT(Max)Package Reference应用领域BL8555Low noise, High PSRR Max 8V 1.2~5.0V±2%/±1%25μA150mA SOT23-5SC70-5XC6212 XC6209 R1114X LP3985手机、对讲机、无绳电话、蓝牙、USB key等BL8563Low noise, High PSRR Max 6V 1.5~4.5V±2%/±1%20µA300mA SOT23-5SC70-5XC6219XC6212XC6209R1114XLP3985手机、对讲机、无绳电话、蓝牙、USB key等BL9193RF PA LDO,Ultra Lownoise, High PSSR 2.5~6V 1.2~5.0V±2%/±1%80μA300mA SOT23-5SC70-5RT9193 SGM2007手机、对讲机、无绳电话、蓝牙、USB key等BL8558Low noise, High PSRR Max 8V 1.2~4.5V±2%/±1%75μA500mA SOT89-3SOT23-5RT9013 RT9017手机、无绳电话、LCD等BL8560Dual channels LDO 1.5~10V 1.2~5.0V±2%/±1%25μA150mA/EachSOT23-6XC6401 R5325手机、摄像头等BL8566Dual channels LDO Max 6V 1.5-4.5V±2%/±1%20µA300mA/EachSOT23-6RT9011 RT9182手机、摄像头等BL8503Low dropout voltage,Low lq 1.5~10V 1.2~6.0V±2%/±1%3μA250mA SOT89-3SOT23-3XC6206MP3、电子玩具、游戏机、鼠标等BL8552Low dropout voltage,Low lq Max 8V 1.2~3.6V±2%2μA300mA SOT23-3XC6206MP3、电子玩具、游戏机、鼠标等BL8553Low dropout voltage,Low lq 2~10V 1.2~5.0V±2%/±1%7μA400mA SOT89-3SOT23-3XC6203无绳电话、电子玩具、游戏机等BL8565Low noise,Lowdropout Max 8V 1.5~4.5V±2%100μA400mA SOT89-3摄像头、U盘、读卡器、硬盘盒等BL8551Wide input voltagerange, Low lq 3.5~24V 2.5~12V±3%9μA150mA TO92SOT89-3HT75xx电表、电子秤、烟雾报警器、电子点火器等BL8567Wide input voltagerange, Low noise Max 12V 2.5~5.0V±2%8μA300mA SOT23-3SOT89-3电子玩具、无线对讲机、无线遥控手柄等Bipolar LDO Linear Regulator (Bipolar低压差线性稳压器)CMOS LDO Linear Regulator (CMOS低压差线性稳压器)Part No.Features VIN Series Cells MaxCharge ChargertypeOutputAccuPackage Reference应用领域BL8572USB charger,C/10charger termination4.25~6.0V1500mA Linear 4.2V±1%SOT23-5LTC4054MP3、PMP、蓝牙、GPS等BL4054Temperatureregulation,tricklecharge,C/10chargetermination,reverseprotection,USBcompliant 4.5~10V1800mA Linear 4.2V±1%SOT23-5TSOT23-5LTC4054MP3、PMP、蓝牙、GPS等Li-ion Battery Charger (锂电池充电芯片)Part No.Power switching MODE VIN VOUT IQ FOSC Eff.Max.duty cycle Accu IOUT Package Referenc应用领域BL8516Built-in 1.5A NPN PWM 3.6~20V ADJ2mA 1.2MHz85%85%±2% 1.2A SOP8车载GPS、车载MP3、车载充电器、路由器、ADSL等BL8519Built-in 2A PFET PWM 3.6~20V ADJ2mA500KHz>85%97%±2%2A SOP8ADSL、车载GPS、车载MP3、车载充电器、路由器L等BL3406B Internal NMOSand PMOS PWM/PulseSkip,Synchronous,PeakCurrentModeControl2.5~5.5V 1.2,1.8,ADJ180μA 1.5MHz96%100%±2%600mA SOT23-5TSOT23-5LTC3406LTC3406BPMP、GPS、PDA等掌上手持设备Part No.MODE VIN VOUT IQ FOSC Eff.Accu PowerswitchingIOUT Package ReferenceBL8505PFM0.8~5.5V 2.7~5.0V40μA150KHz87%±2%InternalMOSFET 300mA SOT89-3BL8530PFM0.8~5.5V 2.5~6.0V100mVStep 4μA350KHz85%±2%InternalMOSFET300mA SOT89-3SOT23-3SOT23-5XC6371AXC6372ABL8534PFM0.8~5.5V 2.5~6.0V100mVStep <20μA150KHz±2%InternalMOSFET300mA SOT89-3SOT23-3SOT23-5XC6371AXC6372ABL8530C VFM0.8~5.5V 2.5~6.0V100mVStep 6μA350KHz90%±2%ExternalMOSFET-SOT23-3SOT23-5BL8545VFM 2.0~6.0V24V Max1μA3MHz80%±2%Internal 1.5ANPN 100mA@20VSOT23-6BL8532PFM0.8~6.0V 6.0V20μA350KHz87%±2%InternalMOSFET 300mA@3.2VSOT89-5LED应用领域LEDLED、电子玩具、血压计、PDALED、电子玩具、血压计、PDALED、电子玩具、血压计、PDAPSP、P-DVD、GPS、DPF、上网本等DC/DC Step-down Converter (降压型DC/DC转换器) DC/DC Step-up Converter (升压型DC/DC转换器)Part No.VIN VDET IQ Accu OutputtypePackage Delay Time ReferenceBL85060.7~10V0.9~6.0V(Step0.1V)0.5μA±2%CMOSorNMOSopendrainSOT23-3SOT89-3SOT23-5N/A3111 808BL85090.7~10V0.9~6.0V(Step0.1V)0.5μA±2%CMOSorNMOSopendrainSOT23-3SOT23-5Adjustable3110 809Part No.Features VIN VREF Accu.IOUT Package应用领域BL431AdjustableVoltage Max 18V 2.5V±0.5%/±1%/±100mA TO92SOT23-3开关电源Part No.MODE Vin No.Channels DrivingCurrentFreq(MHz)Accu.ChannelMatchingPackage ReferenceBL85881X/1.5X ChargePump 2.7~5.5V420mAX 415%3%QFN16CP2133应用领域便携设备电池电压检测、CPU或逻辑电路上电掉电复位等便携设备电池电压检测、CPU或逻辑电路上电掉电复位等应用领域手机Shunt Regulator (电压基准)Charge Pump LED Driver (电荷泵型LED背光驱动电路Voltage detector/Reset IC (电压检测器/复位IC)Part No.MODE VIN No.Channels DrivingCurrentFreq.(MHz)Accu.ChannelMatchingPackage ApplicationReferenceBL8580Linear 2.7~6V320mAx3N/A±3%N/A SOT23-6LEDbacklightAMC7110 BL8581Linear 2.8~5.5V420mA×4N/A±3%±3%MSOP8LEDbacklightAMC7111 BL8581A Linear 2.8~5.5V420mA×4N/A±3%±3%QFN16LEDbacklightKTD108BL8589Linear 2.8~5.5V1650mA×16(Max)25±1%±1.5%SSOP24 QFN24LEDdisplayTCA62746BL8583Linear 2.8~6.5V330mA×3(Max)15N/A N/A SOP14LEDdisplayBL8586Linear 2.8~6.5V630mA×6(Max)15N/A N/A SSOP20LEDdisplay2QL9712BL8585Linear5~90V140mA(Max)N/A±10%N/A TO92LEDlightingCL2Part No.MODE VIN VOUT IQ FOSC Eff.Switch Package BL8508PWM2~10V36V700μA900KHz80%Internal SOT-23-5BL8532PFM0.8~6V6V20μA350KHz87%Internal SOT-89-5BL8545VFM 2.0~6.0V24V Max1μA3MHz80%Internal1.5A NPN SOT23-6LED BacklightLED灯条LED应用领域PSP、P-DVD、GPS、DPF等LEDPSP、P-DVD、GPS、DPF、上网本等应用领域LED、手机、MP3等LED、手机、MP3等LED、手机、MP3等LED显示屏、手机跑马灯、手机呼吸灯等LED灯条Linear Constant LED Driver (线性恒流LED驱动电路)Step-up White LED Driver (升压型LED背光/照明驱动电路)ApplicationStep-up converter to drivetwo to six 20~40mA whiteLEDsStep-up converter todrive one or two 1Wwhite LEDs。