西门子工业以太网交换机选型手册201011
SCALANCE X
߾ᄽᅜྪ࣑ऐ
ׂᄣԨ
• 11.2010
ׂᄣԨ• 11.2010SCALANCE X߾ᄽᅜྪ࣑ऐ
2SCALANCE XSCALANCE Ċ
Ⴀీჽቛ
ဇோጱඇणׯጲۯࣅᅙሞඇ൰߳ںׯࠀᄇᅷକຕْ
ࡗࠌၛ߾ਏࢅՔጚࣅऐLjํ၄णׯਦݛӄăፌዘᄲ
ڦएإ߾ፕኮᅃ৽ዂ૰ᇀ
SIMATIC NET߾ᄽཚრڦ݀ቛă
SCALANCE
Scalable PerformanceڦႀLjဇோጱ݀ቛᆶ
ᇸྪஏഗॲڦႎڦײԘă!ኄၵᆶᇸྪஏևॲྜெ၎ࢻၹཞLjኼሞჹ੯ڦ߾ᄽ࣍ৣူ
ీࠕणׯĂଳऄĂҾඇĂߛႠీںࠓॺ߾ᄽᅜྪă
SCALANCE W!
ᆩᇀ߾ᄽ၍ਆᇘྪڦ੍၍ۉरຍ
एᇀ߾ᄽ၍ۉਆᇘྪLj
SCALANCE Wॽणׯཚრྊቛڟᅃ߲ࡗඁవฯփ
ీڦଶᇘă
SCALANCE Wཚࡗጆᆩڦຕد୲ई॔੦၍থፔ
ڟኄۅă
SCALANCE W֑ᆩକ
IEEE 802.11a / b / g / h / e / i၍ਆᇘྪࡔाՔጚăW
߾ᄽ၍ਆᇘྪSCALANCE X
ࢇ߾ᄽ࣍ৣڦ߾ᄽᅜྪ࣑ऐ
SCALANCE X߾ᄽᅜྪ࣑ऐዖૌഋඇLj࣑๕߾ᄽᅜྪྪஏڦࢃ႐ă़
ኧ
SNMPࢅ
WEBኑLjᄺኧ
PROFINETኑă༵ࠃକ߾ᄽपยऺڦߛ੍ႠĂ
ߛᆩႠࢅྼࢺ०ՍႠăX
߾ᄽᅜྪ࣑ऐ
SCALANCE S
ԍኤ߾ᄽҾඇ
૧ᆩҾඇऐLjසණኤĂຕेईݡ࿚੦Lj
SCALANCE Sᅜԍࢺ߾ᄽྪஏ
ࢅຕဣཥ௨թ۾ൔလĂ֡੦ࢅ࿄ঢ়ڦݡ࿚ăS
ҾඇႠ
3SCALANCE X߾ᄽ࣍ৣူڦཚრ
߾ᄽཚრᇑӸࠅ࣍ৣူڦཚრᆶጣߵԨฉڦփཞăሞӸࠅ࣍
ৣူLjܠᆩࢽথᅃޜခഗǗਜ਼ࢽኮक़ժுᆶ֮থă
ܸኄዖຕدሞॺ૬ཚრথ้Ljܠ߲ᆩࢽཞ้থޜခ
ഗ้ࣷڞዂፆࢅჽ้ă
ኄփీᆩᇀጲۯ੦Ljᅺྺთ࣍ڦኴႜײتႴᄲ߸
ႎڦຕઠܔፇॲ݀ᆌڦ੦ኸସă
ُྔLjᆌᆩरຍLjཚრ࠲ဣࢅྪஏࠓᄺՂႷ߳ጲీࠕᆌ
ჹ੯ڦ߾ᄽ࣍ৣă
߾ᄽྪஏՂႷీࠕݒᆌଳऄժሞ܌้क़ాፁׇႴ൱Ljዘ
ፇՂႷܸߛၳăஃසࢆLjՂႷඓԍྪஏڦඹଉतፌٷ
၌܈૧ᆩഄยԢࢅऐഗLjॽཕऐ้क़३ڟፌၭăᆶڦิׂ
ࡗײࢅ࠶ײՂႷྜඇࢻۯă!ኄᅃᄲ൱ኻᆶړඇࠅິࢅഓᄽྔևۼ֑ᆩକਸݣڦཚრဣཥ
้֍ీፁăሞጲۯࣅࢅ႑တरຍଶᇘዐᆌՆ௨֑ᆩࠜ૬๕
ਦݛӄLjᅺُႴᄲፁᅜူڦब߲മ༵ཉॲǖ
Ŗ!ٗدߌഗ0ኴႜഗ֫ڟࠅິ࠶पدໃჄڦ႑တୁ
Ŗ!ඇྪ߲ںۅڦ႑တᆶၳႠ
Ŗ!ሞ߾ևோኮक़ํ၄ຕڦ࣑
Ŗ!०ڇڦඇݔྷࡗײፇༀࢅߛၳڦኑ
Ŗ!ጹࢇڦणׯҾඇࠀీतܔݥݡ࿚ڦፆኹ
ඇणׯጲۯࣅ
SIMATIC NETڦጲۯࣅᄲ໎ඇणׯጲۯࣅ)
TIA*रຍLjኄᅃ
ዖ܋ڟ܋ݔྷڦׂࢅဣཥLjᆩᇀᆶႜᄽڦጲۯࣅଶᇘLj
ٗऋڟׂڦิׂࡗײڟୁLjٗ၄ׇपᅃڟࠅິ
ڦ࠶पăኄၵፇॲڦ༬ਏᆶፌٷײ܈ڦणׯLjᅺྺ
்ۼݡ࿚ᅃ߲ࠅᆩڦຕăኄᄣবูକׯԨLj்ܸ
ᆼԍኤኝ߲ၜణڦᅃዂႠă
ᆩႠᇑႠీ
ሞ߳ዖጲۯࣅᆌᆩዐLjܔᇀߛႠీྪஏࢅߛᆩႠྪஏڦႴ
൱ኟሞփሺăړևຈᅃ߲ิׂ၍ईኁิׂڇᇮ้Lj߳ዖ
ڦྊ೫ݛ݆Lj૩සጺ၍႙Lj࣍႙ईኁ႓႙Lj༵ࠃକ࠽ݘڦ
ీႠă
߾ᄽᅜྪᅃዖޙࢇ
IEEE 802.3)ᅜྪ*ࢅ
802.11)၍ਆ
ᇘྪ*ՔጚڦߛႠీڦਆᇘྪஏăཚࡗ߾ᄽᅜྪLjᆩࢽీॺ
૬ߛႠీݔྷཚრྪஏă
PROFINETྪஏਸݣڦĂՔጚڦ
ࢅํ้ڦ߾ᄽᅜྪLj़ᅜํ၄ํ้੦Ljᄺᅜํ၄ߛ
܈ڦڪ้ํ้੦ă
4SCALANCE Xᆩᇀ߾ᄽᅜྪڦྪஏႠీࢅྪஏरຍ
5
1000 Mbit/s2000 Mbit/s10000 Mbit/s10 Gbit/s10000 Mbit/s20 Gbit/s
1000 Mbit/s
200 Mbit/s
100 Mbit/s
40 Mbit/s*)
20 Mbit/s
10 Mbit/s
4 Mbit/s*)100 Mbit/s1000 Mbit/s
100 Mbit/s
100 Mbit/s
10 Mbit/s
10 Mbit/s
10 Mbit/s
+
*ᆯᇀ؋ሰׯڦํाᆶၳڦຕཾུଉ!
ሞࢇକႎरຍኮࢫLjణമڦ߾ᄽᅜྪႠీLjডፌ؛ڦ
10
Mbitӷມ߾ྪஏ༵ߛ
50Ԡฯ߸ߛăኄၵरຍԈઔǖ
Ŗ!ᅜྪLjد୲
100 Mbit/s;
!Ԓ࿔دԲᅜྪ)
10 Mbit/s*߸Ljጺ၍ᆩ้क़ट܌ă
Ŗ!ྤቹᅜྪLjد୲
10 Gbit/s;
!ྤቹᅜྪԲᅜྪ
100ԠLjጺ၍ᆩ้क़ৈྺഄ
ӥݴኮᅃă
Ŗ!ඇມ߾ݞኹ؋ǖ
!ᆯᇀՆ௨କᆩԒ࿔ڦዘްLj၂ዸ༵ߛକدཚრଉăଇ
߲ྪஏবۅक़ཞ้دࢅথຕăᅺُLjएᇀඇມ߾
থᅜྪڦຕཾུଉ༵ߛڟ
200Mbit/sLjഥቹᅜ
ྪڦຕཾུଉ༵ߛڟ
2Gbit/săඇມ߾๑߸ٷ၌܈ྪஏક
ቛׯྺీă
Ŗ!࣑रຍኧժႜཚრ;
!සࡕ๑ᆩ࣑ऐॽྪஏݴׯब߲ྪLjํ၄ሜݴă
߳ྪኮक़ڦຕ܀૬ᇀഄᆶྪLjሞ߳ጲྪా
ႜཚრăᅺُLjܠ߲Ԓ࿔ཞ้ሞኝ߲ྪஏాدăᆯ
ᇀཞׂ้ิႹܠຕኡLjႠీڥڟ༵ߛă!!5߲ྪஏবۅڦຕཾུଉ
Ŗ!๑ᆩጲۯ֮ࠀీLjኧ݀ໃ၍ࢅথ၍ሞມজ၍থ੨ጲ
ۯ֮ă
Ŗ!ጲᆌ)
Autosensing*ࠀీ๑ྪஏবۅ)ຕዕ܋ࢅྪஏ
ևॲ*ጲۯںॠ֪႑ࡽڦد୲)
10Mbit/sĂ
100Mbit/sई
1Gbit/s*Ljժኧጲۯၹฆă
Ŗ!ጲۯၹฆᅜྪڦᅃዖದዃၹᅱăሞഔۯํाຕ
دമLjྪஏยԢࣷጲۯၹฆᅃ߲ᆯඪࢆጎዃ)
100ቹ0௱
ई
10ቹ0௱Ljඇມ߾ईӷມ߾*༵ࠃڦدఇ๕ă
Ŗ!ഥቹ࿋ք၍ဣཥ
ઠጲ
SIMATIC NETڦ
8ႊ
FastConnectք၍ဣཥኧ
1Gbit/sڦدၳ୲ă
5SCALANCE X߾ᄽᅜྪ࣑ऐ
Ċ!ጲۯࣅྪஏڦࢃ႐
߾ᄽᅜྪ࣑ऐᅃዖᆶᇸྪஏፇॲLjኧփཞڦྪஏྊ೫
ࠓǖጺ၍ႚĂ႓ႚई࣍ႚ࠼ბईۉഘྪஏăኄၵᆶᇸྪஏ
ፇॲᅜӝຕدڟ༬ۨڦణՔںă
SCALANCE Xׂဣଚඇႎᅃپڦ
SIMATIC NET߾ᄽᅜྪ
࣑ऐăᆯփཞڦఇࣅׂ၍ፇׯLjኄၵׂ၍ᄺᆩ
ᇀ
PROFINETڦᆌᆩLjժᇑ၎࠲ڦጲۯ੦ඪခ၎ၹཞă
࣑ྪஏ
࠼္ڞ༹ईມজ၍ۉમᅜᆩፕ࣑ऐኮक़ڦدăຕ
ዕ܋ईྪሶཚࡗມজ၍ۉમথă
ኄዖ࣑रຍሎႹժႜཚრLj૩සLjᅃ߲ྪஏԥݴྺຕ߲ྪ
Ljܸٗᆶዺᇀইگྪஏሜڦ߰ăኄᄣᅃઠ߳ྪኮक़
ڦຕཚრ၎ࢻ܀૬ںႜتăኄ৽ᅪ࿆ጣLjᅜཞ้د
ܠዘၩတă!࣑रຍਏᆶᅜူ༬Ⴀ;
Ŗ!࣑ऐԥᆩᇀࠓॺጱྪࢅྪ
Ŗ!ཚࡗܔຕୁࠓۙኝLj༵ߛຕཾུଉࢅྪஏႠీ
Ŗ!ഄྪஏದዃࡀሶ०ڇ
Ŗ!ᅜݛՍںํ၄ᆶ
50߲࣑ऐࢅඇևકቛٳ
150 kmڦ
ྪஏྊ೫ࠓLjܸႴࠥत႑ࡽد้क़
Ŗ!ཚࡗথ߲߳؋ᇘࢅጱྪLj๑ྪஏڥڟ၌ڦકቛ)ڍ
ړג
150 kmڦ้ࢪLjՂႴᄲ୯႑ࡽدխڦْຕ*
Ŗ!၄ᆶྪஏԥ०ڇޭፕᆩڦકቛ
߾ᄽᅜྪ࣑ऐࠀీ
Ŗ!ߵ၄ᆶথ੨ڦຕణLj࣑ऐᅜଣ้ժۯༀڦཞ้থ
बܔጱྪࢅবۅ
Ŗ!ཚࡗߵຕዕ܋ڦᅜྪ)
MAC*ںLjࡗ୳ຕᄽခLj
Ԩںຕᄽခᅈ৹ԨںڦǗ࣑ऐኻدໃڟഄጱྪᆩ
ࢽڦຕ
Ŗ!ᇑدཥᅃ߲ۆ႙ڦᅜྪྪஏ၎ԲLjኄᄣᅃઠᅜথ߸
ܠڦຕዕ܋
Ŗ!ፆኹٱဃၠᆶ࠲ڦጱྪકො
SCALANCE X߾ᄽᅜྪ࣑ऐᆫ
Ŗ!ॕࠦĂظႎĂবูक़ڦྔยऺLjݥඹᅟںणׯڟ!
SIMATICਦݛӄዐ)ስՔጚ
35mm DINڞࡆĂ
S7-300!
DINڞࡆईথ഻ՄҾጎ*
Ŗ!༫ཤ๕ยऺLjᅜत
PROFINET߾ᄽᅜྪথ֭ཀྵ
FastConnect RJ45 180֭ཀྵඁأᆌ૰ࢅ౦૰
Ŗ!ߛරᇆ༬ႠLjܔᇀ
SCALANCE X-200Ă
SCALANCE X-300
ई
SCALANCE X-400Ljዘႎፇༀܠٳ
50࣑ऐڦ
࣍ྪ)=
0.3௱*
Ŗ!SCALANCE X-300त
SCALANCE X-400༵ࠃڦ
Standy࣍ྪ᳘
ࢇࠀీ
西门子全系列触摸屏选型手册
使用 TIA 博途软件进行工程组态
/fom效率达到新高度SIMATIC HMI
机器可视化的
最佳选择生产效率新基准,
打造可持续性竞争优势
高效工程,成就创新
瑞士 Solinaut 公司是一家工程服务与自动化解决方案提供商,
凭借与西门子的密切合作以及西门子性能卓越的 TIA 博途系
统,致力于显著提高客户的经济效益。
由于 TIA 博途工程组态系统中,只需一步操作即可创建多个参
数,而且所有块都保存在系统的各个库中,极大缩短了程序员
的开发时间。因此,Solinaut 只需重点关注自动化解决方案中
的数据直观清晰显示问题即可。
正是基于以上优势,该公司才能为客户量身定制不同的解决方
案。Altendorf 奶酪制品厂作为他们的主要客户,从中获益匪浅。
视觉的盛宴 — 奶酪的美味需要亲自品尝,方能感受其魅力
随着全球市场竞争的日益激烈,许多与 Altendorf 奶酪制品厂相似的企业开始使用自动化系统。一方面,自动化系统可充分
发掘设备或工厂在整个生命周期内的潜能,显著降低生产能耗。
另一方面,这种系统操作直观易用,产品质量一目了然。正是基于以下优势,系统集成商 Solinaut 为 Altendorf 奶酪制
品厂定制的专业可视化解决方案才能获得巨大成功:
• 在流程图中集成各种特定的画面模板,极大简化了操作员的
操作过程
• 使用滑入窗口和弹出窗口,实现各种功能快速访问
• 集成更多控件,支持远程维护。
如今,乳制品厂对自动化系统的投资回报已初见成效。生产时
间也仅为过去的一半,能源与生产用水量同时也获得了显著降
低。公司负责人 Erich Keller 对工厂的未来发展充满信心。
更多资讯,敬请访问: /hmi-video-altendorf
2
识别
决策SIMATIC HMI — 智能界面 (sm@rt interface)
作为人机对话的唯一接口,HMI 解决方案可实现完美的交互且
优势彰显:
西门子SCALANCE X208 managed IE 交换机数据手册说明书
Data sheet6GK5208-0BA10-2AA3
SCALANCE X208, managed IE switch, 8x 10/100 Mbit/s RJ45 ports,
LED diagnostics, error-signaling contact with set button, redundant
power supply, PROFINET IO device, network management,
Redundancy Manager integrated, incl. electron. manual on CD-ROM,
C-plug optional
Product type designationSCALANCE X208
Transmission rate
Transfer rate10 Mbit/s, 100 Mbit/s
Interfaces / for communication / integrated
Number of electrical connections
● for network components or terminal equipment8
Number of 10/100 Mbit/s RJ45 ports / Integrated
● with securing collar8
Interfaces / others
Number of electrical connections
● for signaling contact1
● for power supply1
● for redundant voltage supply1
Type of electrical connection
● for signaling contact2-pole terminal block
● for power supply4-pole terminal block
design of the removable storage
西门子管网交换机
西门子交换机SCALANCE X路由用户指导手册
SIEMENS Switch SCALANCE X Route User Guide
User Guide Edition(2007-1)
SIEMENS A&D CS
摘 要 随着PROFINET和SCALANCE在中国市场的不断深入,越来越多的用户选择和使用
PROFINET和SCALANCE。SCALANCE X414-3E是西门子全新推出的高性能交换机,全
面支持PROFINET,支持冗余管理RM,支持热备STBY。除了交换机的基本功能外,还支
持IT标准的通讯,例如:TFTP,SMTP等等。SCALANCE X414-3E同样支持VLAN和路
由。VLAN可以隔离网络上的广播域,但VLAN之间通讯只能通过路由。所以有VLAN,必
有路由。SCALANCE X414-3E具有3层交换的路由功能,这样它就可以成为网络上的核心
部件-----路由器。除了支持静态路由外,还支持动态的路由协议,例如RIPv2和OSPFv2。
这样可以满足用户各种各样的控制要求和网络要求。本手册全面讲述了SCALANCE X414-
3E的各种路由,用户可以根据本手册了解和掌握SCALACNE X400的路由组态,并应用到
工业控制和工业网络中。
关键词 SCALANCE X414-3E,路由,本地路由,静态路由,RIP,OSPF
Key words SCALANCE X414-3E,Route,Local Route,Static Route,RIP,OSPF
A&D Service & Support
Page 2-34
目 录
第一章SCALANCE X-400路由概述......................................................................................4
1.1 VLAN概述....................................................................................................................4
西门子SCALANCE X212-2Managed IE交换机数据手册说明书
Data sheet6GK5212-2BB00-2AA3
SCALANCE X212-2, MANAGED IE SWITCH, 12 X 10/100MBIT/S
RJ45 PORTS, 2 X 100MBIT/S MULTIMODE BFOC, LED-
DIAGNOSTICS, FAULT SIGNAL. CONTACT WITH SET BUTTON,
REDUNDANT POWER SUPPLY PROFINET-IO DEVICE,
NETWORK- MANAGEMENT, INTEGRATED REDUNDANCY
MANAGER, INCL. ELECTRONIC MANUAL ON CD, C-PLUG
OPTIONAL
Transmission rate
Transfer rate10 Mbit/s, 100 Mbit/s
Interfaces / for communication / integrated
Number of electrical connections
● for network components or terminal equipment12
Number of 100 Mbit/s ST(BFOC) ports
● for multimode2
Number of 100 Mbit/s SC ports
● for multimode0
Number of 1000 Mbit/s LC ports
● for multimode0
● for single mode (LD)0
Interfaces / others
Number of electrical connections
● for signaling contact1
● for power supply1
● for redundant voltage supply1Type of electrical connection
6GK5212-2BB00-2AA3Subject to change without notice
SICOM3000A-LITE 工业以太网交换机 硬件安装手册说明书
SICOM3000A-LITE工业以太网交换机
硬件安装手册
出版日期:2019年03月
版 本:V1.0
编 号:112020173
SICOM3000A-LITE工业以太网交换机 硬件安装手册 免责声明:北京东土科技股份有限公司竭力使本手册中的信息尽可能准确、最新。然而本公司不能保证本手册完全没有任何技术错误或笔误,并保留在未通知用户的情况下对其修改的权利。 保留所有权限:本手册著作权属北京东土科技股份有限公司所有。未经著作权人书面许可,任何单位或个人不得以任何方式摘录、翻版、复制、翻译或者用于商业目的分发等行为。 侵权必究。 Copyright © 2019Kyland Technology Co., Ltd.
安全使用须知
本产品在设计使用范围内具有良好可靠的性能,但需要避免人为对设备造成的损害或破坏。使用设备前,请仔细阅读该手册,以保障用户人身和设备的安全。阅读后请妥善保管本手册,以备将来参考。对于违反安全使用须知造成的人身伤害或设备损坏,我司不承担任何责任。 请勿将设备放置、安装在接近水源或潮湿的地方,保持设备周边的相对湿度在5%~95%范围内且无凝结。 请勿将设备放置、安装在高磁、强震或高温的地方,保持设备的工作、存储温度在规定范围内。 保持设备放置稳妥,防止坠落;保持设备安装紧固,防止滑脱。 保持设备及周边环境清洁,必要时可用干软棉布擦拭。 请勿在设备或线缆上放置杂物,保持设备散热通畅,线缆顺畅无打结。 操作设备时需佩戴防静电手套或采取其他安全防护。 接线时避免金属线裸露,防止金属线高温氧化或联电。 需按照本国、本地电器法规安装设备。 上电前需确认设备支持的电源规格,防止电压过高损坏设备。 保持电源插头及其它设备连接件连接牢固,防止接触不良影响使用。 请勿用湿手插拔电源,断电前请勿用湿手触摸设备及设备配套零件。 操作带电设备前,请取下首饰(戒指、手镯、手表、项链等)或其他金属物品,防止触电或烫伤。 雷电天气时,请勿操作设备或连接、断开线缆。 请使用我司市场人员或技术支持人员认可的连接器和线缆,避免由于连接器和线缆不符合规范而影响模块功能。 请勿自行拆解设备,设备故障或疑似故障时,请咨询我司市场人员或技术支持人员。 设备零件遗失时,请在我司市场人员或技术支持人员的指导下购买替代零件,严禁私自选配。 需按照国家相关规定报废设备,减少对环境的污染。 在下列情况下,请立即断开电源,并与我司取得联系。 设备进水。 设备摔坏或机壳破裂。 设备工作异常或性能改变。 设备产生异味、烟雾或异常噪音。
2010 台湾oring工业交换机选型资料
Generated by Foxit PDF Creator © Foxit Software
For evaluation only.Generated by Foxit PDF Creator © Foxit Software
For evaluation only.Generated by Foxit PDF Creator © Foxit Software
For evaluation only.Generated by Foxit PDF Creator © Foxit Software
For evaluation only.Generated by Foxit PDF Creator © Foxit Software
For evaluation only.Generated by Foxit PDF Creator © Foxit Software
For evaluation only.Generated by Foxit PDF Creator © Foxit Software
For evaluation only.Generated by Foxit PDF Creator © Foxit Software
For evaluation only.Generated by Foxit PDF Creator © Foxit Software
西门子SCALANCE X212-2 managed交换机说明书
6GK52122BB002AA3 Page 1/22.20.2021Subject to change without notice
© Copyright Siemens Data sheet6GK5212-2BB00-2AA3SCALANCE X212-2, managed IE switch, 12x 10/100 Mbit/s RJ45 ports, 2x 100 Mbit/s multimode BFOC, LED diagnostics, error-signaling contact with set button, redundant power supply, PROFINET IO device, network management, redundancy manager integrated, incl. electron. manual on CD-ROM, C-plug optionalproduct type designationSCALANCE X212-2transfer ratetransfer rate10 Mbit/s, 100 Mbit/sinterfaces / for communication / integratednumber of electrical connections● for network components or terminal equipment12number of 10/100 Mbit/s RJ45 ports / integrated● with securing collar12number of 100 Mbit/s ST(BFOC) ports● for multimode2interfaces / othernumber of electrical connections● for signaling contact1● for power supply1type of electrical connection● for signaling contact2-pole terminal block● for power supply4-pole terminal blockdesign of the removable storage● C-PLUGYessignal inputs/outputsoperating voltage / of the signaling contacts● at DC / rated value24 Voperational current / of the signaling contacts● at DC / maximum0.1 Asupply voltage, current consumption, power lossproduct component / connection for redundant voltage supplyYestype of voltage / 1 / of the supply voltageDC● supply voltage / 1 / rated value24 V● power loss [W] / 1 / rated value7.92 W● supply voltage / 1 / rated value18 ... 32 V● consumed current / 1 / maximum0.33 A● type of electrical connection / 1 / for power supply4-pole terminal block● product component / 1 / fusing at power supply inputYesambient conditionsambient temperature● during operation-40 ... +60 °C6GK52122BB002AA3 Page 2/32.20.2021Subject to change without notice © Copyright Siemens ● during storage-40 ... +70 °C● during transport-40 ... +70 °Crelative humidity● at 25 °C / without condensation / during operation / maximum95 %protection class IPIP30design, dimensions and weightsdesigncompactwidth120 mmheight125 mmdepth124 mmnet weight1.2 kgfastening method● 35 mm top hat DIN rail mountingYes● wall mountingYes● S7-300 rail mountingYes● S7-1500 rail mountingNoproduct features, product functions, product components / generalcascading in the case of a redundant ring / at reconfiguration time of <\~0.3\~s100cascading in cases of star topologyany (depending only on signal propagation time)product functions / management, configuration, engineeringproduct function● CLIYes● web-based managementYes● MIB supportYes● TRAPs via emailYes● configuration with STEP 7Yes● port mirroringYes● multiport mirroringNo● with IRT / PROFINET IO switchNo● PROFINET IO diagnosisYesPROFINET conformity classBproduct function / switch-managedYesprotocol / is supported● TelnetYes● HTTPYes● HTTPSYes● TFTPYes● FTPYes● BOOTPNo● DCPYes● LLDPYes● SNMP v1Yes● SNMP v2Yes● SNMP v3Yesidentification & maintenance function● I&M0 - device-specific informationYes● I&M1 – higher level designation/location designationYesproduct functions / diagnosticsproduct function● port diagnosticsYes● statistics Packet SizeYes● statistics packet typeYes● error statisticsYesproduct functions / DHCPproduct function● DHCP clientYes6GK52122BB002AA3 Page 3/42.20.2021Subject to change without notice © Copyright Siemens product functions / redundancyproduct function● ring redundancyYes● High Speed Redundancy Protocol (HRP)Yes● high speed redundancy protocol (HRP) with redundancy managerYes● high speed redundancy protocol (HRP) with standby redundancyNoprotocol / is supported / Media Redundancy Protocol (MRP)Yesproduct function● media redundancy protocol (MRP) with redundancy managerYes● Parallel Redundancy Protocol (PRP)/operation in the PRP-networkYes● Parallel Redundancy Protocol (PRP)/Redundant Network Access (RNA)No● passive listeningYesproduct functions / securityprotocol / is supported● SSHYesproduct functions / timeproduct function● SICLOCK supportYesprotocol / is supported● NTPNo● SNTPYesstandards, specifications, approvalsstandard● for FMFM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4● for safety / from CSA and ULUL 60950-1, CSA C22.2 No. 60950-1● for emitted interferenceEN 61000-6-4:2001 (Class A)● for interference immunityEN 61000-6-2:2001MTBF51.18 ystandards, specifications, approvals / CEcertificate of suitability / CE markingYesstandards, specifications, approvals / hazardous environmentsstandard / for hazardous zoneEN 60079-0: 2006, EN60079-15: 2005, II 3 (2) G Ex nA [op is] IIC T4, KEMA 07 ATEX 0145 X● from CSA and ULANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4certificate of suitability● CCC approval hazardous zoneYesstandards, specifications, approvals / othercertificate of suitabilityEN 61000-6-2:2001, EN 61000-6-4:2001● C-TickYes● KC approvalYes● railway application in accordance with EN 50155No● railway application in accordance with EN 50124-1Nostandards, specifications, approvals / marine classificationMarine classification association● American Bureau of Shipping Europe Ltd. (ABS)Yes● French marine classification society (BV)Yes● Det Norske Veritas (DNV)No● Germanische Lloyd (GL)No● DNV GLYes● Lloyds Register of Shipping (LRS)Yes● Nippon Kaiji Kyokai (NK)Yes
西门子 SCALANCE X106-1 未管理 IE 交换机 数据表说明书
Data sheet6GK5106-1BB00-2AA3
Product type designationSCALANCE X106-1SCALANCE X106-1, UNMANAGED IE SWITCH, 6 X 10/100MBIT/S
RJ45 PORTS, 1 X 100 MBIT/S MULTIMODE BFOC, LED
DIAGNOSTICS, FAULT SIGNAL. CONTACT WITH SET BUTTON,
REDUNDANT VOLTAGE SUPPLY MANUAL AVAILABLE AS
DOWNLOAD
Transmission rate
Transfer rate10 Mbit/s, 100 Mbit/s
Interfaces / for communication / integrated
Number of electrical connections
● for network components or terminal equipment6; RJ45 with securing collar
Number of 100 Mbit/s ST(BFOC) ports
● for multimode1
Number of 100 Mbit/s SC ports
● for multimode0
Number of 1000 Mbit/s LC ports
● for multimode0
● for single mode (LD)0
Interfaces / others
Number of electrical connections
● for signaling contact1
● for power supply1
● for redundant voltage supply1
6GK5106-1BB00-2AA3Subject to change without notice
Page 1/406/19/2017© Copyright SiemensType of electrical connection
西门子plc选型必备2011
CPU
6ES7 211-0AA23-0XB0 CPU221 DC/DC/DC,6输入/4输出
6ES7 211-0BA23-0XB0 CPU221 继电器输出,6输入/4输出
6ES7 212-1AB23-0XB8 CPU222 DC/DC/DC,8输入/6输出
6ES7 212-1BB23-0XB8 CPU222 继电器输出,8输入/6输出
6ES7 214-1AD23-0XB8 CPU224 DC/DC/DC,14输入/10输出
6ES7 214-1BD23-0XB8 CPU224 继电器输出,14输入/10输出
6ES7 214-2AD23-0XB8 CPU224XP DC/DC/DC,14DI/10DO,2AI/1AO
6ES7 214-2BD23-0XB8 CPU224XP 继电器输出,14DI/10DO,2AI/1AO
6ES7 216-2AD23-0XB8 CPU226 DC/DC/DC,24输入/16输出
6ES7 216-2BD23-0XB8 CPU226 继电器输出,24输入/16输出
USB-PPI USB接口的西门子PLC S7-200编程电缆,带指示灯,对应西门子产品:6ES7 901-3DB30-0XA0 ,通信距离达2公里,电缆长度为3米。
USB-PPI+ 隔离型USB 接口的 S7-200PLC 编程电缆,带指示灯,对应西门子产品:6ES7 901-3DB30-0XA0,通信距离达2公里,电缆长度3米。
PC-PPI RS232 接口的西门子 S7-200PLC 编程电缆,RS232/PPI 接口,对应西门子产品号: 6ES7
901-3CB30-0XA0电缆长度为2米(2-50米可供选择)。
USB-MPI+ 隔离型USB接口的西门子 S7-300编程适配器,带通信指示灯,对应型号6ES7 972-0CB20-0XA0
通信距离可达1公里(187.5Kbps 时)长度5米。
西门子 SIMATIC NET Rugged 以太网交换机 RUGGEDCOM RS910 安装手册
安装手册
SIMATIC NET
Rugged 以太网交换机
RUGGEDCOM RS910
https:///ruggedcom
SIMATIC NET
Rugged 以太网交换机
RUGGEDCOM RS910
安装手册前言简介1安装设备2设备管理3通信端口4技术规范5认证6
04/2022
C79000-G8952-1029-13法律资讯
警告提示系统
为了您的人身安全以及避免财产损失,必须注意本手册中的提示。人身安全的提示用一个警告三角表示,仅与财产损失有关的提示不带警告三角。警告提示根据危险等级由高到低如下表示。危险
表示如果不采取相应的小心措施,将会导致死亡或者严重的人身伤害。警告
表示如果不采取相应的小心措施,可能导致死亡或者严重的人身伤害。注意
表示如果不采取相应的小心措施,可能导致轻微的人身伤害。注意
表示如果不采取相应的小心措施,可能导致财产损失。
当出现多个危险等级的情况下,每次总是使用最高等级的警告提示。如果在某个警告提示中带有警告可能导致人身伤害的警告三角,则可能在该警告提示中另外还附带有可能导致财产损失的警告。
合格的专业人员
本文件所属的产品/系统只允许由符合各项工作要求的合格人员进行操作。其操作必须遵照各自附带的文件说明,特别是其中的安全及警告提示。 由于具备相关培训及经验,合格人员可以察觉本产品/系统的风险,并避免可能的危险。
按规定使用 西门子 产品
请注意下列说明:警告
西门子 产品只允许用于目录和相关技术文件中规定的使用情况。如果要使用其他公司的产品和组件,必须得到 西门子 推荐和允许。正确的运输、储存、组装、装配、安装、调试、操作和维护是产品安全、正常运行的前提。必须保证允许的环境条件。必须注意相关文件中的提示。
商标