西门子工业以太网交换机选型手册201011

SCALANCE X

߾ᄽᅜ໿ྪ঍࣑ऐ

ׂ೗ᄣԨ

• 11.2010

ׂ೗ᄣԨ• 11.2010SCALANCE X߾ᄽᅜ໿ྪ঍࣑ऐ

2SCALANCE XSCALANCE Ċ

Ⴀీ੗ჽቛ

ဇோጱඇणׯጲۯࣅ૙౒ᅙሞඇ൰߳ںׯࠀᄇᅷକ࿮ຕْ

ࡗࠌၛ߾ਏࢅՔጚࣅऐ዆Lj੗ํ၄णׯ঴ਦݛӄăፌዘᄲ

ڦएإ߾ፕኮᅃ৽๟ዂ૰ᇀ

SIMATIC NET߾ᄽཚრڦ݀ቛă

SCALANCE๟

Scalable Performanceڦ໫ႀLj๟ဇோጱ݀ቛᆶ

ᇸྪஏഗॲڦႎڦ૛ײԘă!ኄၵᆶᇸྪஏևॲ੗ྜெ၎ࢻၹཞLjኼሞჹ੯ڦ߾ᄽ࣍ৣူ

ీࠕणׯĂଳऄĂҾඇĂߛႠీںࠓॺ߾ᄽᅜ໿ྪă

SCALANCE W!

ᆩᇀ߾ᄽ࿮၍ਆᇘྪڦ੗੍࿮၍ۉरຍ

एᇀ߾ᄽ࿮၍ۉਆᇘྪLj

SCALANCE Wॽणׯཚრྊቛڟᅃ߲ࡗඁ࢔వฯ዁փ

੗ీ৊෇ڦଶᇘă

SCALANCE W๟ཚࡗጆᆩڦຕ਍د๼໏୲ई॔੦࿮၍૶থፔ

ڟኄۅă

SCALANCE W֑ᆩକ

IEEE 802.11a / b / g / h / e / i࿮၍ਆᇘྪࡔाՔጚăW

߾ᄽ࿮၍ਆᇘྪSCALANCE X

๢ࢇ߾ᄽ࣍ৣڦ߾ᄽᅜ໿ྪ঍࣑ऐ

SCALANCE X߾ᄽᅜ໿ྪ঍࣑ऐዖૌഋඇLj๟঍࣑๕߾ᄽᅜ໿ྪྪஏڦࢃ႐ă़

ኧ׼

SNMPࢅ

WEBኑ܏Ljᄺኧ׼

PROFINETኑ܏ă༵ࠃକ߾ᄽपยऺڦߛ੗੍ႠĂ

ߛ੗ᆩႠࢅྼࢺ०ՍႠăX

߾ᄽᅜ໿ྪ঍࣑ऐ

SCALANCE S

ԍኤ߾ᄽҾඇ

૧ᆩҾඇऐ዆LjසණኤĂຕ਍े௢ईݡ࿚੦዆Lj

SCALANCE S੗ᅜԍࢺ߾ᄽྪஏ

ࢅຕ਍ဣཥ௨๴թ۾ൔလĂ֡੦ࢅ࿄ঢ়๲඄ڦݡ࿚ăS

ҾඇႠ

3SCALANCE X߾ᄽ࣍ৣူڦཚრ

߾ᄽཚრᇑӸࠅ࣍ৣူڦཚრᆶጣߵԨฉڦփཞăሞӸࠅ࣍

ৣူLj࢔ܠᆩࢽ૶থᅃ໼ޜခഗǗਜ਼ࢽኮक़ժுᆶ঍֮૶থă

ܸኄዖຕ਍د๼ሞॺ૬ཚრ૶থ้Ljܠ߲ᆩࢽཞ้૶থޜခ

ഗ้ࣷڞዂፆ෗ࢅჽ้ă

ኄփీᆩᇀጲۯ੦዆Ljᅺྺთ࣍ڦኴႜ৊ײت૙Ⴔᄲ๼෇߸

ႎڦຕ਍ઠܔፇॲ݀؜๢ᆌڦ੦዆ኸସă

ُྔLjᆌᆩरຍLjཚრ࠲ဣࢅྪஏ঳ࠓᄺՂႷ߳ጲీࠕ๢ᆌ

ჹ੯ڦ߾ᄽ࣍ৣă

߾ᄽྪஏՂႷీࠕݒᆌଳऄժሞ܌้क़ా஢ፁ๨ׇႴ൱Ljዘ

ፇՂႷ੺໏ܸߛၳă࿮ஃසࢆLjՂႷඓԍྪஏڦඹଉतፌٷ

၌܈૧ᆩഄยԢࢅऐഗLjॽཕऐ้क़३ڟፌၭă໯ᆶڦิׂ

ࡗײࢅ࠶૙৊ײՂႷྜඇࢻۯă!ኄᅃᄲ൱ኻᆶړඇࠅິࢅഓᄽྔևۼ֑ᆩକਸݣڦཚრဣཥ

้֍ీ஢ፁăሞጲۯࣅࢅ႑တरຍଶᇘዐᆌՆ௨֑ᆩࠜ૬๕

঴ਦݛӄLjᅺُႴᄲ஢ፁᅜူڦब߲മ༵ཉॲǖ

Ŗ!ٗدߌഗ0ኴႜഗ֫ڟࠅິ࠶૙पدໃ૶Ⴤڦ႑တୁ

Ŗ!ඇྪ௅߲ںۅڦ႑တᆶၳႠ

Ŗ!ሞ߾׍ևோኮक़ํ၄ຕ਍ڦ੺໏঍࣑

Ŗ!०ڇڦඇ׍ݔྷࡗײፇༀࢅߛၳڦኑ܏

Ŗ!ጹࢇڦणׯҾඇࠀీतܔݥ๲඄ݡ࿚ڦፆኹ

ඇणׯጲۯࣅ

SIMATIC NETڦጲۯࣅᄲ໎๟ඇणׯጲۯࣅ)

TIA*रຍLjኄ๟ᅃ

ዖ܋ڟ܋ݔྷڦׂ೗ࢅဣཥLj๢ᆩᇀ໯ᆶႜᄽڦጲۯࣅଶᇘLj

ٗ৊ऋڟׂ೗ڦิׂࡗײڟ๼؜࿿ୁLjٗ၄ׇपᅃ኱ڟࠅິ

ڦ࠶૙पăኄၵፇॲڦ༬෥๟ਏᆶፌٷײ܈ڦणׯLjᅺྺ໱

்ۼݡ࿚ᅃ߲ࠅᆩڦຕ਍ăኄᄣবูକ๼෇ׯԨLjܸ൐໱்

ᆼԍኤኝ߲ၜణڦᅃዂႠă

੗ᆩႠᇑႠీ

ሞ߳ዖጲۯࣅᆌᆩዐLjܔᇀߛႠీྪஏࢅߛ੗ᆩႠྪஏڦႴ

൱ኟሞփ܏ሺ׊ăړևຈᅃ߲ิׂ၍ईኁิׂڇᇮ้Lj߳ዖ

ڦྊ೫ݛ݆Lj૩සጺ၍႙Lj࣍႙ईኁ႓႙Lj༵ࠃକ࠽ݘڦ੗

ీႠă

߾ᄽᅜ໿ྪ๟ᅃዖޙࢇ

IEEE 802.3)ᅜ໿ྪ*ࢅ

802.11)࿮၍ਆ

ᇘྪ*ՔጚڦߛႠీڦਆᇘྪஏăཚࡗ߾ᄽᅜ໿ྪLjᆩࢽీॺ

૬ߛႠీ੻ݔྷཚრྪஏă

PROFINETྪஏ๟ਸݣڦĂՔጚڦ

ࢅํ้ڦ߾ᄽᅜ໿ྪLj़੗ᅜํ၄ํ้੦዆Ljᄺ੗ᅜํ၄ߛ

৛܈ڦڪ้ํ้੦዆ă

4SCALANCE X๢ᆩᇀ߾ᄽᅜ໿ྪڦྪஏႠీࢅྪஏरຍ

5󰟲󰾪󰮏󰦬󰛅󰚦󰺕󰨍󰽾󰽴󰬉

1000 Mbit/s󰶇󰺡󰟾󰽚󱃠2000 Mbit/s10000 Mbit/s󰶇󰺡󰟾󰽚󱃠10 Gbit/s10000 Mbit/s󰶇󰺡󰟾󰽚󱃠20 Gbit/s

1000 Mbit/s

200 Mbit/s

100 Mbit/s

40 Mbit/s*)

20 Mbit/s

10 Mbit/s

4 Mbit/s*)100 Mbit/s󰶇󰺡󰟾󰽚󱃠1000 Mbit/s󰦍󰣑󱂙󰽚󱃠

100 Mbit/s󰦍󰣑󱂙󰽚󱃠

100 Mbit/s󰠌󱁛󱂙󰽚󱃠

10 Mbit/s󰶇󰺡󰟾󰽚󱃠

10 Mbit/s󰦍󰣑󱂙󰽚󱃠

10 Mbit/s󰠌󱁛󱂙󰽚󱃠

+

*ᆯᇀ؋཭ሰׯڦํाᆶၳڦຕ਍ཾུଉ!

ሞ঳ࢇକႎरຍኮࢫLjణമڦ߾ᄽᅜ໿ྪႠీLjডፌ؛ڦ

10

Mbitӷມ߾ྪஏ༵ߛ

50Ԡฯ዁߸ߛăኄၵरຍԈઔǖ

Ŗ!੺໏ᅜ໿ྪLjد๼໏୲

100 Mbit/s;

!Ԓ࿔د๼Բᅜ໿ྪ)

10 Mbit/s*߸੺Ljጺ၍቞ᆩ้क़ट܌ă

Ŗ!ྤቹᅜ໿ྪLjد๼໏୲

10 Gbit/s;

!ྤቹᅜ໿ྪԲ੺໏ᅜ໿ྪ੺

100ԠLjጺ၍቞ᆩ้क़ৈྺഄ

ӥݴኮᅃă

Ŗ!ඇມ߾ݞኹ؋཭ǖ

!ᆯᇀՆ௨କ׉ᆩԒ࿔ڦዘްLj၂ዸ༵ߛକد๼ཚრଉăଇ

߲ྪஏবۅक़੗ཞ้د๼ࢅথ๭ຕ਍ăᅺُLjएᇀඇມ߾

૶থ੺໏ᅜ໿ྪڦຕ਍ཾུଉ༵ߛڟ

200Mbit/sLjഥቹᅜ໿

ྪڦຕ਍ཾུଉ༵ߛڟ

2Gbit/săඇມ߾๑߸ٷ၌܈ྪஏક

ቛׯྺ੗ీă

Ŗ!঍࣑रຍኧ׼ժႜཚრ;

!සࡕ๑ᆩ঍࣑ऐॽྪஏݴׯब߲ྪ܎Lj੗ํ၄޶ሜݴ૗ă

߳ྪ܎ኮक़ڦຕ਍੗܀૬ᇀഄ໲໯ᆶྪ܎Ljሞ߳ጲྪ܎ా

৊ႜཚრăᅺُLjܠ߲Ԓ࿔੗ཞ้ሞኝ߲ྪஏాد๼ăᆯ

ᇀཞׂ้ิႹܠຕ਍ኡLjႠీڥڟ༵ߛă!󰀂!5߲ྪஏবۅڦຕ਍ཾུଉ

Ŗ!๑ᆩጲۯ঍֮ࠀీLjኧ׼݀ໃ၍ࢅথ๭၍ሞມজ၍থ੨ጲ

ۯ঍֮ă

Ŗ!ጲ๢ᆌ)

Autosensing*ࠀీ๑ྪஏবۅ)ຕ਍ዕ܋ࢅྪஏ

ևॲ*ጲۯںॠ֪႑ࡽڦد๼໏୲)

10Mbit/sĂ

100Mbit/sई

1Gbit/s*Ljժኧ׼ጲۯၹฆă

Ŗ!ጲۯၹฆ๟੺໏ᅜ໿ྪڦᅃዖದዃၹᅱăሞഔۯํाຕ਍

د๼മLjྪஏยԢࣷጲۯၹฆᅃ߲ᆯඪࢆጎዃ)

100ቹ0௱

ई

10ቹ0௱Ljඇມ߾ईӷມ߾*༵ࠃڦد๼ఇ๕ă

Ŗ!ഥቹ࿋ք၍ဣཥ

ઠጲ

SIMATIC NETڦ

8ႊ

FastConnectք၍ဣཥ੗ኧ׼

1Gbit/sڦد๼ၳ୲ă

5SCALANCE X߾ᄽᅜ໿ྪ঍࣑ऐ

Ċ!ጲۯࣅྪஏڦࢃ႐

߾ᄽᅜ໿ྪ঍࣑ऐᅃዖᆶᇸྪஏፇॲLjኧ׼փཞڦྪஏྊ೫

঳ࠓǖጺ၍ႚĂ႓ႚई࣍ႚ࠼ბईۉഘྪஏăኄၵᆶᇸྪஏ

ፇॲ੗ᅜӝຕ਍د๼ڟ༬ۨڦణՔں኷ă

SCALANCE Xׂ೗ဣଚ๟ඇႎᅃپڦ

SIMATIC NET߾ᄽᅜ໿ྪ

঍࣑ऐă໲ᆯփཞڦఇ੷ࣅׂ೗၍ፇׯLjኄၵׂ೗၍ᄺ๢ᆩ

ᇀ

PROFINETڦᆌᆩLjժᇑ၎࠲ڦጲۯ੦዆ඪခ၎ၹཞă

঍࣑ྪஏ

࠼္ڞ༹ईມজ၍ۉમ੗ᅜᆩፕ঍࣑ऐኮक़ڦد๼௃঻ăຕ

਍ዕ܋ईྪ܎ሶཚࡗມজ၍ۉમ૶থă

ኄዖ঍࣑रຍሎႹժႜཚრLj૩සLjᅃ߲ྪஏԥݴྺຕ߲ྪ

܎Ljܸٗᆶዺᇀইگྪஏ޶ሜڦ߰૗ăኄᄣᅃઠ߳ྪ܎ኮक़

ڦຕ਍ཚრ၎ࢻ܀૬ں৊ႜت૙ăኄ৽ᅪ࿆ጣLj੗ᅜཞ้د

๼ܠዘၩတă!঍࣑रຍਏᆶᅜူ༬Ⴀ;

Ŗ!঍࣑ऐ੗ԥᆩᇀࠓॺጱྪࢅྪ܎

Ŗ!ཚࡗܔຕ਍ୁ঳ࠓۙኝLj༵ߛຕ਍ཾུଉࢅྪஏႠీ

Ŗ!ഄྪஏದዃࡀሶ०ڇ

Ŗ!੗ᅜݛՍںํ၄ᆶ

50߲঍࣑ऐࢅඇևકቛ੗ٳ

150 kmڦ

ྪஏྊ೫঳ࠓLjܸ࿮Ⴔࠥत႑ࡽد๼้क़

Ŗ!ཚࡗ૶থ߲߳؋཭ᇘࢅጱྪLj੗๑ྪஏڥڟ࿮၌ڦકቛ)ڍ

ړג؜

150 kmڦ้ࢪLjՂႴᄲ੊୯႑ࡽدխڦْຕ*

Ŗ!၄ᆶྪஏ੗ԥ०ڇ࿮ޭፕᆩڦકቛ

߾ᄽᅜ໿ྪ঍࣑ऐࠀీ

Ŗ!ߵ਍၄ᆶথ੨ڦຕణLj঍࣑ऐ੗ᅜଣ้ժۯༀڦཞ้૶থ

बܔጱྪࢅবۅ

Ŗ!ཚࡗߵ਍ຕ਍ዕ܋ڦᅜ໿ྪ)

MAC*ں኷Ljࡗ୳ຕ਍ᄽခLj

Ԩںຕ਍ᄽခᅈ৹๟ԨںڦǗ঍࣑ऐኻدໃڟഄ໲ጱྪᆩ

ࢽڦຕ਍

Ŗ!ᇑدཥᅃ߲ۆ႙ڦᅜ໿ྪྪஏ၎ԲLjኄᄣᅃઠ੗ᅜ૶থ߸

ܠڦຕ਍ዕ܋

Ŗ!ፆኹٱဃၠᆶ࠲ڦጱྪકො

SCALANCE X߾ᄽᅜ໿ྪ঍࣑ऐᆫ๞

Ŗ!ॕࠦĂظႎĂবู੣क़ڦྔ੕ยऺLj੗ݥ׉ඹᅟںणׯڟ!

SIMATIC঴ਦݛӄዐ)੗჋ስՔጚ

35mm DINڞࡆĂ

S7-300!

DINڞࡆई኱থ഻ՄҾጎ*

Ŗ!༫ཤ๕ยऺLjᅜत

PROFINET߾ᄽᅜ໿ྪ૶থ֭ཀྵ

FastConnect RJ45 180֭ཀྵ੗ඁأᆌ૰ࢅ౦૰

Ŗ!ߛ໏රᇆ༬ႠLjܔᇀ

SCALANCE X-200Ă

SCALANCE X-300

ई

SCALANCE X-400Lj੗੺໏ዘႎፇༀܠٳ

50໼঍࣑ऐڦ

࣍ྪ)=

0.3௱*

Ŗ!SCALANCE X-300त

SCALANCE X-400༵ࠃڦ

Standy࣍ྪ᳘

ࢇࠀీ

合集下载

西门子全系列触摸屏选型手册

西门子全系列触摸屏选型手册

使用 TIA 博途软件进行工程组态

/fom效率达到新高度SIMATIC HMI

机器可视化的

最佳选择生产效率新基准,

打造可持续性竞争优势

高效工程,成就创新

瑞士 Solinaut 公司是一家工程服务与自动化解决方案提供商,

凭借与西门子的密切合作以及西门子性能卓越的 TIA 博途系

统,致力于显著提高客户的经济效益。

由于 TIA 博途工程组态系统中,只需一步操作即可创建多个参

数,而且所有块都保存在系统的各个库中,极大缩短了程序员

的开发时间。因此,Solinaut 只需重点关注自动化解决方案中

的数据直观清晰显示问题即可。

正是基于以上优势,该公司才能为客户量身定制不同的解决方

案。Altendorf 奶酪制品厂作为他们的主要客户,从中获益匪浅。

视觉的盛宴 — 奶酪的美味需要亲自品尝,方能感受其魅力

随着全球市场竞争的日益激烈,许多与 Altendorf 奶酪制品厂相似的企业开始使用自动化系统。一方面,自动化系统可充分

发掘设备或工厂在整个生命周期内的潜能,显著降低生产能耗。

另一方面,这种系统操作直观易用,产品质量一目了然。正是基于以下优势,系统集成商 Solinaut 为 Altendorf 奶酪制

品厂定制的专业可视化解决方案才能获得巨大成功:

• 在流程图中集成各种特定的画面模板,极大简化了操作员的

操作过程

• 使用滑入窗口和弹出窗口,实现各种功能快速访问

• 集成更多控件,支持远程维护。

如今,乳制品厂对自动化系统的投资回报已初见成效。生产时

间也仅为过去的一半,能源与生产用水量同时也获得了显著降

低。公司负责人 Erich Keller 对工厂的未来发展充满信心。

更多资讯,敬请访问: /hmi-video-altendorf

2

识别

决策SIMATIC HMI — 智能界面 (sm@rt interface)

作为人机对话的唯一接口,HMI 解决方案可实现完美的交互且

优势彰显:

西门子SCALANCE X208 managed IE 交换机数据手册说明书

西门子SCALANCE X208 managed IE 交换机数据手册说明书

Data sheet6GK5208-0BA10-2AA3

SCALANCE X208, managed IE switch, 8x 10/100 Mbit/s RJ45 ports,

LED diagnostics, error-signaling contact with set button, redundant

power supply, PROFINET IO device, network management,

Redundancy Manager integrated, incl. electron. manual on CD-ROM,

C-plug optional

Product type designationSCALANCE X208

Transmission rate

Transfer rate10 Mbit/s, 100 Mbit/s

Interfaces / for communication / integrated

Number of electrical connections

● for network components or terminal equipment8

Number of 10/100 Mbit/s RJ45 ports / Integrated

● with securing collar8

Interfaces / others

Number of electrical connections

● for signaling contact1

● for power supply1

● for redundant voltage supply1

Type of electrical connection

● for signaling contact2-pole terminal block

● for power supply4-pole terminal block

design of the removable storage

西门子管网交换机

西门子管网交换机

西门子交换机SCALANCE X路由用户指导手册

SIEMENS Switch SCALANCE X Route User Guide

User Guide Edition(2007-1)

SIEMENS A&D CS

摘 要 随着PROFINET和SCALANCE在中国市场的不断深入,越来越多的用户选择和使用

PROFINET和SCALANCE。SCALANCE X414-3E是西门子全新推出的高性能交换机,全

面支持PROFINET,支持冗余管理RM,支持热备STBY。除了交换机的基本功能外,还支

持IT标准的通讯,例如:TFTP,SMTP等等。SCALANCE X414-3E同样支持VLAN和路

由。VLAN可以隔离网络上的广播域,但VLAN之间通讯只能通过路由。所以有VLAN,必

有路由。SCALANCE X414-3E具有3层交换的路由功能,这样它就可以成为网络上的核心

部件-----路由器。除了支持静态路由外,还支持动态的路由协议,例如RIPv2和OSPFv2。

这样可以满足用户各种各样的控制要求和网络要求。本手册全面讲述了SCALANCE X414-

3E的各种路由,用户可以根据本手册了解和掌握SCALACNE X400的路由组态,并应用到

工业控制和工业网络中。

关键词 SCALANCE X414-3E,路由,本地路由,静态路由,RIP,OSPF

Key words SCALANCE X414-3E,Route,Local Route,Static Route,RIP,OSPF

A&D Service & Support

Page 2-34

目 录

第一章SCALANCE X-400路由概述......................................................................................4

1.1 VLAN概述....................................................................................................................4

西门子SCALANCE X212-2Managed IE交换机数据手册说明书

西门子SCALANCE X212-2Managed IE交换机数据手册说明书

Data sheet6GK5212-2BB00-2AA3

SCALANCE X212-2, MANAGED IE SWITCH, 12 X 10/100MBIT/S

RJ45 PORTS, 2 X 100MBIT/S MULTIMODE BFOC, LED-

DIAGNOSTICS, FAULT SIGNAL. CONTACT WITH SET BUTTON,

REDUNDANT POWER SUPPLY PROFINET-IO DEVICE,

NETWORK- MANAGEMENT, INTEGRATED REDUNDANCY

MANAGER, INCL. ELECTRONIC MANUAL ON CD, C-PLUG

OPTIONAL

Transmission rate

Transfer rate10 Mbit/s, 100 Mbit/s

Interfaces / for communication / integrated

Number of electrical connections

● for network components or terminal equipment12

Number of 100 Mbit/s ST(BFOC) ports

● for multimode2

Number of 100 Mbit/s SC ports

● for multimode0

Number of 1000 Mbit/s LC ports

● for multimode0

● for single mode (LD)0

Interfaces / others

Number of electrical connections

● for signaling contact1

● for power supply1

● for redundant voltage supply1Type of electrical connection

6GK5212-2BB00-2AA3Subject to change without notice

SICOM3000A-LITE 工业以太网交换机 硬件安装手册说明书

SICOM3000A-LITE 工业以太网交换机 硬件安装手册说明书

SICOM3000A-LITE工业以太网交换机

硬件安装手册

出版日期:2019年03月

版 本:V1.0

编 号:112020173

SICOM3000A-LITE工业以太网交换机 硬件安装手册 免责声明:北京东土科技股份有限公司竭力使本手册中的信息尽可能准确、最新。然而本公司不能保证本手册完全没有任何技术错误或笔误,并保留在未通知用户的情况下对其修改的权利。 保留所有权限:本手册著作权属北京东土科技股份有限公司所有。未经著作权人书面许可,任何单位或个人不得以任何方式摘录、翻版、复制、翻译或者用于商业目的分发等行为。 侵权必究。 Copyright © 2019Kyland Technology Co., Ltd.

安全使用须知

本产品在设计使用范围内具有良好可靠的性能,但需要避免人为对设备造成的损害或破坏。使用设备前,请仔细阅读该手册,以保障用户人身和设备的安全。阅读后请妥善保管本手册,以备将来参考。对于违反安全使用须知造成的人身伤害或设备损坏,我司不承担任何责任。  请勿将设备放置、安装在接近水源或潮湿的地方,保持设备周边的相对湿度在5%~95%范围内且无凝结。  请勿将设备放置、安装在高磁、强震或高温的地方,保持设备的工作、存储温度在规定范围内。  保持设备放置稳妥,防止坠落;保持设备安装紧固,防止滑脱。  保持设备及周边环境清洁,必要时可用干软棉布擦拭。  请勿在设备或线缆上放置杂物,保持设备散热通畅,线缆顺畅无打结。  操作设备时需佩戴防静电手套或采取其他安全防护。  接线时避免金属线裸露,防止金属线高温氧化或联电。  需按照本国、本地电器法规安装设备。  上电前需确认设备支持的电源规格,防止电压过高损坏设备。  保持电源插头及其它设备连接件连接牢固,防止接触不良影响使用。  请勿用湿手插拔电源,断电前请勿用湿手触摸设备及设备配套零件。  操作带电设备前,请取下首饰(戒指、手镯、手表、项链等)或其他金属物品,防止触电或烫伤。  雷电天气时,请勿操作设备或连接、断开线缆。  请使用我司市场人员或技术支持人员认可的连接器和线缆,避免由于连接器和线缆不符合规范而影响模块功能。  请勿自行拆解设备,设备故障或疑似故障时,请咨询我司市场人员或技术支持人员。  设备零件遗失时,请在我司市场人员或技术支持人员的指导下购买替代零件,严禁私自选配。  需按照国家相关规定报废设备,减少对环境的污染。 在下列情况下,请立即断开电源,并与我司取得联系。  设备进水。  设备摔坏或机壳破裂。  设备工作异常或性能改变。  设备产生异味、烟雾或异常噪音。

2010 台湾oring工业交换机选型资料

2010 台湾oring工业交换机选型资料

Generated by Foxit PDF Creator © Foxit Software

For evaluation only.Generated by Foxit PDF Creator © Foxit Software

For evaluation only.Generated by Foxit PDF Creator © Foxit Software

For evaluation only.Generated by Foxit PDF Creator © Foxit Software

For evaluation only.Generated by Foxit PDF Creator © Foxit Software

For evaluation only.Generated by Foxit PDF Creator © Foxit Software

For evaluation only.Generated by Foxit PDF Creator © Foxit Software

For evaluation only.Generated by Foxit PDF Creator © Foxit Software

For evaluation only.Generated by Foxit PDF Creator © Foxit Software

西门子SCALANCE X212-2 managed交换机说明书

6GK52122BB002AA3 Page 1/22.20.2021Subject to change without notice

© Copyright Siemens Data sheet6GK5212-2BB00-2AA3SCALANCE X212-2, managed IE switch, 12x 10/100 Mbit/s RJ45 ports, 2x 100 Mbit/s multimode BFOC, LED diagnostics, error-signaling contact with set button, redundant power supply, PROFINET IO device, network management, redundancy manager integrated, incl. electron. manual on CD-ROM, C-plug optionalproduct type designationSCALANCE X212-2transfer ratetransfer rate10 Mbit/s, 100 Mbit/sinterfaces / for communication / integratednumber of electrical connections● for network components or terminal equipment12number of 10/100 Mbit/s RJ45 ports / integrated● with securing collar12number of 100 Mbit/s ST(BFOC) ports● for multimode2interfaces / othernumber of electrical connections● for signaling contact1● for power supply1type of electrical connection● for signaling contact2-pole terminal block● for power supply4-pole terminal blockdesign of the removable storage● C-PLUGYessignal inputs/outputsoperating voltage / of the signaling contacts● at DC / rated value24 Voperational current / of the signaling contacts● at DC / maximum0.1 Asupply voltage, current consumption, power lossproduct component / connection for redundant voltage supplyYestype of voltage / 1 / of the supply voltageDC● supply voltage / 1 / rated value24 V● power loss [W] / 1 / rated value7.92 W● supply voltage / 1 / rated value18 ... 32 V● consumed current / 1 / maximum0.33 A● type of electrical connection / 1 / for power supply4-pole terminal block● product component / 1 / fusing at power supply inputYesambient conditionsambient temperature● during operation-40 ... +60 °C6GK52122BB002AA3 Page 2/32.20.2021Subject to change without notice © Copyright Siemens ● during storage-40 ... +70 °C● during transport-40 ... +70 °Crelative humidity● at 25 °C / without condensation / during operation / maximum95 %protection class IPIP30design, dimensions and weightsdesigncompactwidth120 mmheight125 mmdepth124 mmnet weight1.2 kgfastening method● 35 mm top hat DIN rail mountingYes● wall mountingYes● S7-300 rail mountingYes● S7-1500 rail mountingNoproduct features, product functions, product components / generalcascading in the case of a redundant ring / at reconfiguration time of <\~0.3\~s100cascading in cases of star topologyany (depending only on signal propagation time)product functions / management, configuration, engineeringproduct function● CLIYes● web-based managementYes● MIB supportYes● TRAPs via emailYes● configuration with STEP 7Yes● port mirroringYes● multiport mirroringNo● with IRT / PROFINET IO switchNo● PROFINET IO diagnosisYesPROFINET conformity classBproduct function / switch-managedYesprotocol / is supported● TelnetYes● HTTPYes● HTTPSYes● TFTPYes● FTPYes● BOOTPNo● DCPYes● LLDPYes● SNMP v1Yes● SNMP v2Yes● SNMP v3Yesidentification & maintenance function● I&M0 - device-specific informationYes● I&M1 – higher level designation/location designationYesproduct functions / diagnosticsproduct function● port diagnosticsYes● statistics Packet SizeYes● statistics packet typeYes● error statisticsYesproduct functions / DHCPproduct function● DHCP clientYes6GK52122BB002AA3 Page 3/42.20.2021Subject to change without notice © Copyright Siemens product functions / redundancyproduct function● ring redundancyYes● High Speed Redundancy Protocol (HRP)Yes● high speed redundancy protocol (HRP) with redundancy managerYes● high speed redundancy protocol (HRP) with standby redundancyNoprotocol / is supported / Media Redundancy Protocol (MRP)Yesproduct function● media redundancy protocol (MRP) with redundancy managerYes● Parallel Redundancy Protocol (PRP)/operation in the PRP-networkYes● Parallel Redundancy Protocol (PRP)/Redundant Network Access (RNA)No● passive listeningYesproduct functions / securityprotocol / is supported● SSHYesproduct functions / timeproduct function● SICLOCK supportYesprotocol / is supported● NTPNo● SNTPYesstandards, specifications, approvalsstandard● for FMFM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4● for safety / from CSA and ULUL 60950-1, CSA C22.2 No. 60950-1● for emitted interferenceEN 61000-6-4:2001 (Class A)● for interference immunityEN 61000-6-2:2001MTBF51.18 ystandards, specifications, approvals / CEcertificate of suitability / CE markingYesstandards, specifications, approvals / hazardous environmentsstandard / for hazardous zoneEN 60079-0: 2006, EN60079-15: 2005, II 3 (2) G Ex nA [op is] IIC T4, KEMA 07 ATEX 0145 X● from CSA and ULANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4certificate of suitability● CCC approval hazardous zoneYesstandards, specifications, approvals / othercertificate of suitabilityEN 61000-6-2:2001, EN 61000-6-4:2001● C-TickYes● KC approvalYes● railway application in accordance with EN 50155No● railway application in accordance with EN 50124-1Nostandards, specifications, approvals / marine classificationMarine classification association● American Bureau of Shipping Europe Ltd. (ABS)Yes● French marine classification society (BV)Yes● Det Norske Veritas (DNV)No● Germanische Lloyd (GL)No● DNV GLYes● Lloyds Register of Shipping (LRS)Yes● Nippon Kaiji Kyokai (NK)Yes

西门子 SCALANCE X106-1 未管理 IE 交换机 数据表说明书

Data sheet6GK5106-1BB00-2AA3

Product type designationSCALANCE X106-1SCALANCE X106-1, UNMANAGED IE SWITCH, 6 X 10/100MBIT/S

RJ45 PORTS, 1 X 100 MBIT/S MULTIMODE BFOC, LED

DIAGNOSTICS, FAULT SIGNAL. CONTACT WITH SET BUTTON,

REDUNDANT VOLTAGE SUPPLY MANUAL AVAILABLE AS

DOWNLOAD

Transmission rate

Transfer rate10 Mbit/s, 100 Mbit/s

Interfaces / for communication / integrated

Number of electrical connections

● for network components or terminal equipment6; RJ45 with securing collar

Number of 100 Mbit/s ST(BFOC) ports

● for multimode1

Number of 100 Mbit/s SC ports

● for multimode0

Number of 1000 Mbit/s LC ports

● for multimode0

● for single mode (LD)0

Interfaces / others

Number of electrical connections

● for signaling contact1

● for power supply1

● for redundant voltage supply1

6GK5106-1BB00-2AA3Subject to change without notice

Page 1/406/19/2017© Copyright SiemensType of electrical connection

西门子plc选型必备2011

CPU

6ES7 211-0AA23-0XB0 CPU221 DC/DC/DC,6输入/4输出

6ES7 211-0BA23-0XB0 CPU221 继电器输出,6输入/4输出

6ES7 212-1AB23-0XB8 CPU222 DC/DC/DC,8输入/6输出

6ES7 212-1BB23-0XB8 CPU222 继电器输出,8输入/6输出

6ES7 214-1AD23-0XB8 CPU224 DC/DC/DC,14输入/10输出

6ES7 214-1BD23-0XB8 CPU224 继电器输出,14输入/10输出

6ES7 214-2AD23-0XB8 CPU224XP DC/DC/DC,14DI/10DO,2AI/1AO

6ES7 214-2BD23-0XB8 CPU224XP 继电器输出,14DI/10DO,2AI/1AO

6ES7 216-2AD23-0XB8 CPU226 DC/DC/DC,24输入/16输出

6ES7 216-2BD23-0XB8 CPU226 继电器输出,24输入/16输出

USB-PPI USB接口的西门子PLC S7-200编程电缆,带指示灯,对应西门子产品:6ES7 901-3DB30-0XA0 ,通信距离达2公里,电缆长度为3米。

USB-PPI+ 隔离型USB 接口的 S7-200PLC 编程电缆,带指示灯,对应西门子产品:6ES7 901-3DB30-0XA0,通信距离达2公里,电缆长度3米。

PC-PPI RS232 接口的西门子 S7-200PLC 编程电缆,RS232/PPI 接口,对应西门子产品号: 6ES7

901-3CB30-0XA0电缆长度为2米(2-50米可供选择)。

USB-MPI+ 隔离型USB接口的西门子 S7-300编程适配器,带通信指示灯,对应型号6ES7 972-0CB20-0XA0

通信距离可达1公里(187.5Kbps 时)长度5米。

西门子 SIMATIC NET Rugged 以太网交换机 RUGGEDCOM RS910 安装手册

安装手册

SIMATIC NET

Rugged 以太网交换机

RUGGEDCOM RS910

https:///ruggedcom

SIMATIC NET

Rugged 以太网交换机

RUGGEDCOM RS910

安装手册前言简介1安装设备2设备管理3通信端口4技术规范5认证6

04/2022

C79000-G8952-1029-13法律资讯

警告提示系统

为了您的人身安全以及避免财产损失,必须注意本手册中的提示。人身安全的提示用一个警告三角表示,仅与财产损失有关的提示不带警告三角。警告提示根据危险等级由高到低如下表示。危险

表示如果不采取相应的小心措施,将会导致死亡或者严重的人身伤害。警告

表示如果不采取相应的小心措施,可能导致死亡或者严重的人身伤害。注意

表示如果不采取相应的小心措施,可能导致轻微的人身伤害。注意

表示如果不采取相应的小心措施,可能导致财产损失。

当出现多个危险等级的情况下,每次总是使用最高等级的警告提示。如果在某个警告提示中带有警告可能导致人身伤害的警告三角,则可能在该警告提示中另外还附带有可能导致财产损失的警告。

合格的专业人员

本文件所属的产品/系统只允许由符合各项工作要求的合格人员进行操作。其操作必须遵照各自附带的文件说明,特别是其中的安全及警告提示。 由于具备相关培训及经验,合格人员可以察觉本产品/系统的风险,并避免可能的危险。

按规定使用 西门子 产品

请注意下列说明:警告

西门子 产品只允许用于目录和相关技术文件中规定的使用情况。如果要使用其他公司的产品和组件,必须得到 西门子 推荐和允许。正确的运输、储存、组装、装配、安装、调试、操作和维护是产品安全、正常运行的前提。必须保证允许的环境条件。必须注意相关文件中的提示。

商标

所有带有标记符号 ® 的都是 西门子加拿大有限公司 的注册商标。本印刷品中的其他符号可能是一些其他商标。若第三方出于自身目的使用这些商标,将侵害其所有者的权利。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
相关文档
最新文档