卡鲁塞尔氧化沟处理城市污水的设计计算

合集下载

卡鲁塞尔氧化沟设计计算

卡鲁塞尔氧化沟设计计算
卡罗塞尔氧化沟
.1设计参数
1)氧化沟座数:1座
2)氧化沟设计流量: =183L/s
3)进水水质: =220 mg/L
COD=300 mg/L
SS=300 mg/L
-N 35 mg/L
T-P=4 mg/L
T-N=30 mg/L
4)出水水质: 20 mg/L
COD 60 mg/L
SS 20 mg/L
-N 8 mg/L
需要硝化的氧量:
Nr=20 15811.2 10-3=316.2.kg/d
R=0.5 15811.2 (0.19-0.0064)+0.1 4712.5 4
+4.6 316.2-2.6 316.2
=3969kg/d=165.4kg/h
取T=30℃,查表得α=0.8,β=0.9,氧的饱和度 =7.63 mg/L, =9.17 mg/L
查手册,选用DY325型倒伞型叶轮表面曝气机,直径Ф=3.5m,电机功率N=55kW,单台每小时最大充氧能力为125kgO2/h,每座氧化沟所需数量为n,则 取n=3台
(8)回流污泥量:
活性污泥的计算是以固体总量为基础的
由式:
式中: Q---污水厂设计流量(m³/d)
---回流污泥量(m³/d)
---进水中SS浓度(mg/L)取厌氧池出水浓度150 mg/L
式中:
---硝化速率1/d ;
a---污泥增长系数一般为 0.5~0.7,取0.6;
b---污泥自身氧化率,一般为0.04~0.1, 取0.05(1/d) ;
活性污泥浓度MLSS一般为20000mg/L一40000mg/L (也可采用高达60000 mg/L) ,这里取MLSS=40000mg/L,在一般情况下,MLVSS ( 混合液可挥发性悬浮固体浓度) 与MLSS的比值是比较的固定的, 在0.75左右。在这里取0.7.

《2024年卡鲁塞尔氧化沟处理城市污水的设计计算》范文

《2024年卡鲁塞尔氧化沟处理城市污水的设计计算》范文

《卡鲁塞尔氧化沟处理城市污水的设计计算》篇一一、引言随着城市化进程的加速,城市污水处理成为环境保护和可持续发展的关键问题。

卡鲁塞尔氧化沟技术作为一种高效、稳定的污水处理方法,被广泛应用于城市污水处理领域。

本文将详细介绍卡鲁塞尔氧化沟处理城市污水的设计计算过程,以期为相关工程提供参考。

二、设计依据与目标设计依据主要包括国家及地方相关污水处理标准、规范,以及卡鲁塞尔氧化沟技术的原理和特点。

设计目标则是根据城市污水的实际情况,确定合适的处理工艺,确保出水水质达到国家排放标准,同时降低能耗、减少运行成本。

三、设计计算1. 污水来源及性质分析首先需要对城市污水进行来源及性质分析,包括生活污水、工业废水等。

通过实验室检测,获取污水中各类污染物的浓度、pH值等关键参数,为后续设计计算提供依据。

2. 设计流量计算根据城市人口、用水量等因素,计算污水处理厂的设计流量。

同时考虑未来城市发展的需求,合理预测污水处理厂的流量变化。

3. 卡鲁塞尔氧化沟工艺参数选择卡鲁塞尔氧化沟工艺参数包括沟深、沟宽、水力停留时间等。

根据设计流量和出水水质要求,选择合适的工艺参数。

同时考虑沟内微生物的生长和代谢规律,优化工艺参数。

4. 动力设备选型与计算根据设计流量和工艺参数,选择合适的动力设备,如曝气机、推进器等。

计算设备的功率、数量等关键参数,确保设备满足污水处理需求。

5. 污泥处理与处置污泥处理与处置是污水处理过程中的重要环节。

根据污泥的性质和产量,选择合适的处理方法,如污泥浓缩、污泥脱水等。

同时考虑污泥的最终处置方式,如土地利用、焚烧等。

6. 控制系统设计控制系统是保证污水处理厂稳定运行的关键。

根据工艺需求,设计合理的控制系统,包括自动监测、自动控制等功能。

确保污水处理厂在各种工况下都能稳定运行。

四、总结与展望本文详细介绍了卡鲁塞尔氧化沟处理城市污水的设计计算过程。

通过分析污水来源及性质、设计流量计算、工艺参数选择、动力设备选型与计算、污泥处理与处置以及控制系统设计等方面,为相关工程提供了参考。

《2024年卡鲁塞尔氧化沟处理城市污水的设计计算》范文

《2024年卡鲁塞尔氧化沟处理城市污水的设计计算》范文

《卡鲁塞尔氧化沟处理城市污水的设计计算》篇一一、引言随着城市化进程的加速,城市污水处理问题日益突出。

卡鲁塞尔氧化沟作为一种有效的污水处理技术,因其处理效率高、操作简便等优点,被广泛应用于城市污水处理中。

本文将详细介绍卡鲁塞尔氧化沟处理城市污水的设计计算过程,以期为相关工程提供参考。

二、设计依据与基本参数1. 设计依据:根据国家相关污水处理标准、规范及地方环保要求,结合实际污水处理需求,确定设计依据。

2. 基本参数:包括进水水质、处理水量、处理效果要求等。

其中,进水水质应包括COD(化学需氧量)、BOD5(生物需氧量)、SS(悬浮物)、NH3-N(氨氮)等指标;处理水量应根据实际需求进行确定;处理效果要求应达到国家相关标准。

三、工艺流程设计1. 预处理:通过格栅、沉砂池等设备去除污水中的大颗粒杂质和悬浮物,降低后续处理难度。

2. 卡鲁塞尔氧化沟处理:将预处理后的污水引入卡鲁塞尔氧化沟,通过曝气、搅拌等作用,使污水中的有机物得到充分氧化分解。

3. 沉淀池处理:将氧化沟处理后的污水引入沉淀池,通过自然沉淀、混凝等作用进一步去除污水中的悬浮物和沉淀物。

4. 消毒:采用次氯酸钠等消毒剂对沉淀池出水进行消毒,杀灭残留的细菌、病毒等微生物。

5. 排放:经上述处理后,出水达到国家相关排放标准,可排放至江河湖泊等自然水体。

四、卡鲁塞尔氧化沟设计计算1. 沟体设计:根据处理水量、停留时间等要求,确定沟体尺寸。

沟体材质应采用耐腐蚀、耐磨损的材料,如钢筋混凝土等。

2. 曝气系统设计:曝气系统是卡鲁塞尔氧化沟的关键设备,应根据沟体尺寸、水深、曝气强度等参数进行设计。

同时,应考虑能耗、维护等因素。

3. 搅拌系统设计:搅拌系统用于保证污水在沟内充分混合、氧化,提高处理效率。

搅拌方式可采用机械搅拌或曝气搅拌等方式。

4. 进出水系统设计:进出水系统应保证进出水流畅、均匀,避免短流、死角等现象。

同时,应考虑进出水管道的布置、连接方式等因素。

卡鲁塞尔氧化沟设计计算

卡鲁塞尔氧化沟设计计算

Ko2 --- 氧的半速常数( mg/L)取 1.3 mg/L
n 0.47e0.098 10 15
8 8 100. 05 10 1.158
2 1.3 2
=0.166 L/d
故泥龄 0.166
采用安全系数为 3.0 ,故设计污泥龄为: 3.0 6.02=18.06 d
原假定污泥龄为 20d,则硝化速率为:
还原 NO3-N 的总量 = 20 15811 316.22 kg 1000
脱氮所需 MLVSS=316.22 5270.3 kg 0.06
脱氮所需池容: Vdn
5270.3
1882.25
3
m
2。8
水力停留时间: tdn 1882.25 24 3 h 15811.2
(4)氧化沟的总容积:
总水力停留时间:
N N 100. 05T 1 .158
式中: n --- 硝化菌的生长率( d 1 )
( n) max --- 硝化菌的最大生长率( d 1 )
O2 K O2 O2
N--- 出水中 NH 4 N 的浓度( mg/L)取 15 mg/L
Kn --- 硝化的半速常数 T--- 温度(取最不利温度 10℃) O 2 --- 氧化沟中溶解氧浓度( mg/L)取 2.0 mg/L
实用文案
卡罗塞尔氧化沟 .1 设计参数
1) 氧化沟座数: 1 座 2) 氧化沟设计流量: Qmax =183 L/s
3) 进水水质: BOD 5 =220 mg/L
COD=300 mg/L SS=300 mg/L
NH 3 -N 35 mg/L
T-P=4 mg/L T-N=30 mg/L
4) 出水水质: BOD 5 20 mg/L

卡罗塞尔氧化沟工艺污水处理厂设计方案

卡罗塞尔氧化沟工艺污水处理厂设计方案

卡罗塞尔氧化沟工艺污水处理厂设计方案1 设计概述1.1 设计依据及设计任务1.1.1 设计题目卡罗塞尔氧化沟工艺污水处理厂设计1.1.2设计原始资料《环境工程专业》毕业设计任务书(一)排水体制:完全分流制(二)污水量1.城市设计人口 38万人,居住建筑设有室给排水卫生设备和淋浴设备。

2.城市公共建筑污水量按城市生活污水量的30%计。

3.工业污水量为28000m3/d,其中包括工业企业部生活淋浴污水。

4.城市混合污水变化系数:日变化系数K日=1.15,总变化系数KZ=1.35。

(三)水质:1.当地环保局监测工业废水的水质为:BOD5=290mg/L COD=560mg/L SS=230mg/LTN=44mg/L NH3-N=28mg/L TP=4.5mg/LPH=7~82.城市生活污水水质:COD=380mg/L NH3-N=35mg/L TN=40mg/L TP=3.6mg/L(四)出水水质污水处理厂出水水质参考《城镇污水处理厂污染物排放标准》(GB18918-2002)中的一级B标准,因此确定本污水厂出水水质控制为:CODCr ≤60mg/L SS≤20mg/L BOD5≤20mg/LTN=20mg/L NH-N=8(15)mg/L TP≤1mg/L3城市污水经处理后,30%作为城市景观环境用水,用于湖泊水源水。

出水水质应执行《景观环境用水的再生水水质指标(GB/T 18921-2002)》要求。

(五)气象资料l、气温:年平均气温12.30℃,夏季平均气温30℃,极端最高气温30℃,冬季最高气温-8℃,极端最低气温-18.3℃。

2、风向风速:主导风向夏季为南风,冬季为北风,最大风速20m/s(六)水体资料河流最高水位55.0m(五十年一遇洪水位)正常水位 53.9 m ,最低水位53.00,河底高程51.5m(七)厂区地面平坦,厂区设计地面标高为59.5 m,(八)污水处理厂进水干管数据污水管进厂管底标高52.6m,管径1400mm 充满度0.85m1.1.3设计容和要求1.通过阅读中外文文献,调查研究并收集有关资料,确定合适的污水、污泥及中水处理工艺流程,进行各个构筑物的水利计算。

《2024年卡鲁塞尔氧化沟处理城市污水的设计计算》范文

《2024年卡鲁塞尔氧化沟处理城市污水的设计计算》范文

《卡鲁塞尔氧化沟处理城市污水的设计计算》篇一一、引言随着城市化进程的加速,城市污水处理成为了一个亟待解决的问题。

卡鲁塞尔氧化沟技术作为一种有效的污水处理方法,被广泛应用于城市污水处理领域。

本文将介绍卡鲁塞尔氧化沟处理城市污水的设计计算,以期为相关工程提供参考。

二、设计背景与目标本设计旨在为某城市污水处理厂提供一套卡鲁塞尔氧化沟处理系统,以实现对城市污水的有效处理和资源化利用。

设计目标包括:确保出水水质达到国家排放标准,提高污水处理效率,降低能耗和药耗,实现经济、环保、可持续的污水处理。

三、设计计算1. 工艺流程设计卡鲁塞尔氧化沟工艺流程主要包括预处理、氧化沟处理、沉淀池处理、污泥处理及回用等环节。

预处理阶段主要去除污水中的大颗粒杂质和悬浮物;氧化沟处理阶段通过微生物的作用,对污水进行生物降解和净化;沉淀池处理阶段则将净化后的水进行沉淀和澄清;污泥处理阶段则对产生的污泥进行脱水、稳定和利用。

2. 设计参数计算(1)进水水质参数:根据实际进水水质情况,确定COD、BOD5、SS、氨氮等关键参数的浓度范围。

(2)设计流量计算:根据实际需求和预测,确定污水处理厂的设计流量。

(3)氧化沟尺寸计算:根据进水水质参数、设计流量、水力停留时间等参数,计算氧化沟的尺寸。

(4)曝气设备计算:根据氧化沟内的溶解氧需求、曝气设备的性能参数等,计算曝气设备的数量和布置。

(5)沉淀池及污泥处理设备计算:根据出水水质要求、沉淀池的尺寸和形状、污泥的处理方式等,计算沉淀池及污泥处理设备的参数和数量。

四、关键技术要点1. 生物相的调控:通过控制氧化沟内的溶解氧浓度、温度、pH值等条件,调控生物相的组成和数量,保证处理效果。

2. 污泥的处理与利用:采用合理的污泥处理方法,如机械脱水、稳定化处理等,将污泥进行资源化利用,如制作肥料或燃料等。

3. 节能降耗:通过优化工艺流程、选用高效设备、合理布置管道等方式,降低能耗和药耗,实现节能降耗。

城市污水处理工艺设计(卡鲁塞尔氧化沟)

城市污水处理工艺设计(卡鲁塞尔氧化沟)

摘要随着经济的发展,近几年我国水污染控制所面临的问题也愈加严重。

我国人均水资源占有量远小于世界平均水平。

而水环境污染的加剧与水质的普遍恶化,使得水资源供需矛盾进一步加剧,这导致了人们开始担心饮用水水质的安全性。

如何建设全国城镇污水处理及再生利用设施、提升基本环境公共服务水平、促进主要污染物减排和改善水环境质量成为了当下主要的问题。

本次毕业设计的题目为城市污水处理厂工程设计,本设计采用卡鲁塞尔氧化沟工艺。

本设计的主要内容是工艺流程的选择;构筑物的设计、选型与计算;平面布置和高程布置;绘制城市污水厂平面布置图、高程图、工艺流程图及主要构筑物的施工图。

城市污水的水质特点为水中有机物、氨氮浓度较低,可生化性较好,适宜采用生物处理工艺进行处理。

本设计的污水处理厂进水水质为:COD cr=220mg/L,BOD5=100mg/L,SS=200mg/L,TN=30mg/L,NH3-N=20mg/L,pH=6~9。

经组合工艺处理后,污水处理厂出水水质为:COD cr≤60mg/L,BOD5≤20mg/L,SS≤20mg/L,TN≤20mg/L,NH3-N≤8mg/L,pH=6~9。

满足《城镇污水处理厂污染物排放标准》(GB18918-2002)中的一级B标准。

关键词:城市污水,卡鲁塞尔氧化沟,生物处理Designing of 1.1×105m3/d Municipal Wastewater TreatmentProcessAbstractWith economic development in recent years, the problem of water pollution control are also facing increasingly serious. China's per capita possession of water resources far less than the world average. Exacerbate the general deterioration of water quality and water pollution, water supply and demand makes further intensified. This has led people began to worry about the safety of drinking water. How to build the national sewage treatment and recycling facilities towns, enhance the level of basic public services, the environment, and promote emissions of major pollutants and improve the water quality of the environment has become a major problem the moment.The topic of the thesis is finding out some combined technologies to treat the municipal wastewater. The main of the combined technologies is Carrousel oxidation ditch process. The main contents of this design is the process of choice; structures design, selection and calculation; plane layout and height layout; draw the plant layout maps, height layout maps, process flow diagrams and the main building of the construction plans for the municipal wastewater treatment.Low concentrations of organic matter and ammonia is the water quality characteristics of municipal wastewater .And it suitable for processing biological treatment process.The design of the wastewater treatment plant influent water quality: COD cr=220mg/L,BOD5=100mg/L,SS=200mg/L,TN=30mg/L,NH3-N=20mg/L,pH=6~9. After oxidation ditch process,sewage treatment plant effluent quality is COD cr≤60mg/L,BOD5≤20mg/L,SS≤20mg/L,TN≤20mg/L,NH3-N≤8mg/L,pH=6~9. It meets the "urban sewage treatment plant pollutant discharge standard" (GB18918-2002) in a B standard.Keywords:sewage treatment plant, carrousel oxidation ditch, feed water quality of effluent.目录第一章绪论 (1)1.1 城市污水的主要来源 (1)1.2 城市污水的水质水量特点 (1)1.3 城市污水处理现状 (2)1.4 城市污水的处理方法 (3)1.4.1 物理处理方法 (3)1.4.2 化学处理方法 (3)1.4.3 生物处理方法 (3)1.5 本设计的意义及主要研究内容 (4)第二章设计说明 (6)2.1 设计概述 (6)2.1.1 设计任务 (6)2.1.2 设计依据 (6)2.1.3 去除率 (6)2.2 方案选择 (6)2.2.1 确定污水处理方案的原则 (7)2.2.2 污水处理方案的比选 (7)2.2.3 格栅 (9)2.2.4 沉砂池 (9)2.2.5 氧化沟 (9)2.2.6 沉淀池 (11)2.2.7 接触池 (12)2.2.8污泥处理 (13)第三章设计计算 (15)3.1 粗格栅 (15)3.1.1 设计依据 (15)3.1.2 设计计算 (15)3.1.3 计算草图 (17)3.2 进水泵房 (18)3.2.1 设计依据 (18)3.2.2 设计计算 (18)3.3 细格栅 (18)3.3.1 设计依据 (18)3.3.2 设计计算 (19)3.4 沉砂池 (21)3.4.1 设计依据 (21)3.4.2 设计计算 (21)3.4.3 计算草图 (24)3.5 卡鲁塞尔氧化沟 (24)3.5.1 设计依据 (24)3.5.2 设计计算 (25)3.5.3 计算草图 (28)3.6 二沉池 (28)3.6.1 设计依据 (28)3.6.2 设计计算 (28)3.6.3 计算草图 (31)3.7 接触池 (31)3.7.1 设计概述 (31)3.7.2 设计计算 (31)3.7.3 计算草图 (32)3.8 污泥处理系统的设计计算 (32)3.8.1 污泥浓缩池 (32)3.8.2 贮泥池及污泥泵 (33)3.8.3 脱水机房 (34)3.9 污水厂的整体布置 (34)3.9.1 污水厂的高程平面布置 (34)3.9.2 污水厂的高程布置 (35)第四章结论 (37)参考文献 (38)致谢 (39)第一章绪论1.1 城市污水的主要来源城市污水主要包括生活污水和工业污水,由城市排水管网汇集并输送到污水处理厂进行处理。

卡鲁塞尔氧化沟计算

卡鲁塞尔氧化沟计算

卡鲁塞尔氧化沟计算3.5卡鲁塞尔氧化沟计算3.5.1设计参数1、设计依照下列规范6.6.27 进水和回流污泥点宜设在缺氧区首端,出水点宜设在充氧器后的好氧区。

氧化沟的超高与选用的曝气设备类型有关,当采用转刷、转碟时,宜为0.5m;当采用竖轴表曝机时,宜为0.6,0.8m,其设备平台宜高出设计水面0.8,1.2m。

6.6.28 氧化沟的有效水深与曝气、混合和推流设备的性能有关,宜采用3.5~4.5m。

6.6.29 根据氧化沟渠宽度,弯道处可设置一道或多道导流墙;氧化沟的隔流墙和导流墙宜高出设计水位0.2,0.3m。

6.6.30 曝气转刷、转碟宜安装在沟渠直线段的适当位置,曝气转碟也可安装在沟渠的弯道上,竖轴表曝机应安装在沟渠的端部。

6.6.32 氧化沟内的平均流速宜大于0.25m?s。

432、设计流量Q=20×(不考虑变化系数) 10m/d5浓度为S0=250mg/l,Ts浓度为X0=3000mg/l 3、设计进水水质BOD VSS=210mg/l,TN=35mg/L,N H3-N=25mg/l碱度SALK=250mg/l,最低的水温T=7.1 ?,最高的水温T=28.7?平均水温T=18.2?4、设计出水水质,BO D5浓度Se=20mg/l,Ts浓度Xe=20mg/l,N H4-N=8mg/l,TN=20mg/l5、活性污泥浓度即混合液悬浮固体的浓度MLSS=4000mg/l,混合液挥发性悬浮固体的浓度MLVSS XV=2800mg/l;污泥泥龄θc =30d,异养微生物的产率系数Y=0.6kgVSS/kg BO D5。

,O20?时脱硝率为qdn=0.035Kg(还原的N -N)/(kgMLSS?d) 33.5.2设计计算1、氧化沟的容积计算(1)好氧区容积V1,采用动力学计算方法好氧区所需污泥量V1, 混合液浓度YQ(S,S)θ?0c1,Kθdc ,XVY,Y 式中—微生物的净增值量,为表现产率 obs1,KθdcS—氧化沟出水溶解性BOD5浓度。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

卡鲁塞尔氧化沟处理城市污水的设计计算
随着城市化进程的不息加速,城市污水处理成为了一项迫切需要解决的环境问题。

卡鲁塞尔氧化沟作为一种常见的污水处理工艺,具有占地面积小、运行成本低、处理效果好等优点,在城市污水处理中得到了广泛应用。

本文旨在介绍卡鲁塞尔氧化沟的设计计算方法,为城市污水处理提供参考。

二、卡鲁塞尔氧化沟原理
卡鲁塞尔氧化沟是一种利用微生物降解有机物的生物处理工艺,主要包括好氧池和厌氧池。

在好氧池中,污水中的有机物被氧化消化,同步产生生物体和二氧化碳。

而在厌氧池中,生物体通过厌氧代谢进一步降解有机物,产生甲烷等气体。

通过好氧和厌氧的结合运作,可以达到高效处理城市污水的目标。

三、卡鲁塞尔氧化沟的设计参数
1. 水力停留时间(HRT)
水力停留时间是指污水在氧化沟中停留的平均时间,通常以小时为单位。

依据不同的污水处理要求,可以选择适当的水力停留时间,一般建议为3-6小时。

2. 水深(W)
水深是指氧化沟中水面以上的高度,通常以米为单位。

依据污水处理需求和设备尺寸等因素进行选择,一般要求水深在2-5米之间。

3. 氧化沟宽度(B)
氧化沟宽度是指氧化沟截面的宽度,通常以米为单位。

依据
设计流量和水深计算得出,一般建议宽度取5-15米。

4. 氧化沟总长度(L)
氧化沟总长度是指全部氧化沟段的总长度,通常以米为单位。

依据设计流量、水力停留时间和宽度等参数计算得出。

五、卡鲁塞尔氧化沟的设计计算方法
1. 计算污水流量
依据城市污水排放状况和污水处理需求,确定所需处理的污
水流量。

一般可以通过调查资料、测算或猜测等方法得到。

2. 计算好氧池体积
好氧池体积可以通过公式V = Q × HRT计算得出,其中V表
示好氧池体积,Q表示设计流量,HRT表示水力停留时间。

3. 计算厌氧池体积
厌氧池体积可以通过公式V = Q × HRT’计算得出,其中V表
示厌氧池体积,Q表示设计流量,HRT’表示厌氧池中水力停留时间。

4. 计算氧化沟段数
依据设计流量和氧化沟段长度计算得出氧化沟段数。

一般建
议将氧化沟等分为多个段,以便更好地进行控制和管理。

5. 计算氧化沟长度
氧化沟长度可以通过公式L = V / (B × W)计算得出,其中L
表示氧化沟总长度,V表示氧化沟段体积,B表示氧化沟宽度,
W表示水深。

六、结论
通过以上的设计计算方法,我们可以得到详尽的卡鲁塞尔氧
化沟的设计参数,从而为城市污水处理工程的规划和建设提供了
依据。

卡鲁塞尔氧化沟作为一种成熟、高效的污水处理工艺,不
仅可以有效处理城市污水,还具有低运行成本等优点。

在将来城
市化进程中,卡鲁塞尔氧化沟将继续发挥重要作用,为城市环境
保卫和可持续进步做出贡献
设计计算的过程是污水处理工程规划和建设中分外重要的一步。

其中,计算好氧池体积和厌氧池体积的公式是依据设计流量
和水力停留时间来计算得出的。

好氧池和厌氧池的体积大小对于
污水处理效果有着重要的影响,因此需要准确计算。

好氧池的体积计算公式为V = Q × HRT,其中V表示好氧池
体积,Q表示设计流量,HRT表示水力停留时间。

设计流量可以
通过调查资料、测算或猜测等方法得到,而水力停留时间是依据
工程需要确定的一个参数。

依据设计要求,通过将设计流量和水
力停留时间代入公式,就可以得到好氧池的体积。

同样地,厌氧池的体积也可以通过类似的公式进行计算。


氧池的体积计算公式为V = Q × HRT’,其中V表示厌氧池体积,
Q表示设计流量,HRT’表示厌氧池中水力停留时间。

设计流量和
水力停留时间可以通过相同的方法得到,然后代入公式进行计算。

在设计氧化沟时,需要思量氧化沟的段数和长度。

氧化沟的
段数可以依据设计流量和氧化沟段长度计算得出。

一般建议将氧
化沟等分为多个段,以便更好地进行控制和管理。

然后,氧化沟
的总长度可以通过公式L = V / (B × W)计算得出,其中L表示氧
化沟总长度,V表示氧化沟段体积,B表示氧化沟宽度,W表示
水深。

通过以上的设计计算方法,我们可以得到详尽的卡鲁塞尔氧
化沟的设计参数。

卡鲁塞尔氧化沟作为一种成熟、高效的污水处
理工艺,不仅可以有效处理城市污水,还具有低运行成本等优点。

在将来城市化进程中,卡鲁塞尔氧化沟将继续发挥重要作用,为
城市环境保卫和可持续进步做出贡献。

总而言之,设计计算是污水处理工程规划和建设中必不行少
的一环。

通过对设计流量、水力停留时间以及氧化沟段数和长度
等参数的计算,可以得到详尽的设计参数,为工程的规划和建设
提供依据。

卡鲁塞尔氧化沟作为一种有效的污水处理工艺,将在
将来的城市化进程中发挥重要作用
在污水处理工程规划和建设中,设计计算是一个必不行少的
环节。

通过设计流量、水力停留时间以及氧化沟段数和长度等参
数的计算,可以得到详尽的设计参数,为工程的规划和建设提供
依据。

在设计卡鲁塞尔氧化沟时,需要思量厌氧池的体积、设计
流量和水力停留时间,以及氧化沟的段数和长度。

设计流量是指污水处理工程处理的污水流量,可以通过调查
探究或者估算方法得到。

设计流量的确定对于污水处理工程的规
划和建设分外重要,它直接影响着工程设备的选择和工程规模的确定。

水力停留时间是指污水在污水处理工程中停留的时间,它用来评估污水处理过程的效果。

水力停留时间越长,污水处理的效果越好。

水力停留时间的确定需要思量设计流量和污水处理设备的特点,一般通过公式计算得出。

在设计氧化沟时,需要思量氧化沟的段数和长度。

氧化沟的段数可以依据设计流量和氧化沟段长度计算得出。

将氧化沟等分为多个段有利于更好地进行控制和管理。

氧化沟的总长度可以通过公式计算得出,其中思量了氧化沟段的体积、宽度和水深等参数。

卡鲁塞尔氧化沟作为一种成熟、高效的污水处理工艺,在城市污水处理中具有重要的应用价值。

它不仅可以有效处理城市污水,还具有低运行成本等优点。

随着将来城市化进程的加快,卡鲁塞尔氧化沟将继续发挥重要作用,为城市环境保卫和可持续进步做出贡献。

总而言之,设计计算是污水处理工程规划和建设中必不行少的一环。

通过对设计流量、水力停留时间以及氧化沟段数和长度等参数的计算,可以得到详尽的设计参数,为工程的规划和建设提供依据。

卡鲁塞尔氧化沟作为一种有效的污水处理工艺,将在将来的城市化进程中发挥重要作用。

在城市环境保卫和可持续进步的目标下,污水处理工程的合理设计和计算将为城市的可持续进步提供有力支持。

相关文档