摘要:随着国民经济的发展和科技创新的推进,深孔加工技术应用范围越来越广,几乎涉及到所有的机械制造业。其中深孔直线度误差检测一直是困扰深孔加工的一项世界性难题。本文将详细介绍几种深孔直线度误差检测方法。

关键词:深孔加工制造直线度检测

The outlined of deep-hole straightness

measurement method

HAO Yong-peng1,2, YU Da-guo1,2

(1. North University of China, Taiyuan 030051; 2.North University of China, Taiyuan)

Abstract:With the development of national economy and promote technological innovation,deep-hole processing technology increasingly wide range of applications,which almost involving all of the machinery manufacturing industry.Where the deep-hole straightness detection has been plagued deep processing of a world wide problem.This article details several deep-hole straightness detection method.

key words: deep-hole processing manufacturing straightness detection

1.前言

深孔直线度检测是深孔类零件加工过程中的重要组成部分, 是对深孔零件进行质量控制和管理的重要手段。深孔直线度的测量有两方面的要求: 一是精确性要求, 即测量结果必须达到一定的可信程度;二是经济性要求,即在保证测量结果精确性的前提下, 应使测量结果简单、经济[1]。

中北大学深孔加工研究中心在直线度检测方面做了大量工作并取得了长足发展。20世纪90 年代,中北大学王峻等人优化设计排屑钻头,完善排屑容器,将SIED技术应用到深孔加工领域,进而提高了加工孔的直线度。此外,吴伏家、赵长瑞等人针对发动机深孔零件走偏展开研究,测量时工件静止刀具旋转进给,探头与钻头沿工件外作轴线运动,由超声波测厚仪测量孔壁厚,再由壁厚变化可以计算得到深孔轴线直线度误差,该检测装置包括硬件和计算机两大部分。超声波检测方法是一种间接测量方法,检测精度受孔壁外表面质量的影响较大。目前该项技术停留在研究阶段,尚未得到推广应用。中北大学沈兴全、于大国、庞俊忠等发明了基于激光制导的深孔钻削检测与纠偏系统,获得了国家三项发明专利,该方案有待制造样机和进行实验。沈兴全采用外力方法对深孔加工过程中出现偏斜问题进行纠正,通过实验确定恰当的位置,为深孔加工的纠偏做出突出贡献。此外,马清艳、王

彪等人在前人的基础上提出一种新的检测方法,并设计了一套检测装置,该装置主要由激光发射器、位置敏感探测器和自定心装置组成[2,3,4]。

2.直线度检测方法

2.1量规检验法

量规检验法主要用于圆柱表面母线或轴线直线度的检验。在批量生产中,当圆柱体的长度较小,且形位公差为相关公差时,可以用综合量规进行检验。通常,该方法先利用一个长度较短的极限塞规测量合格后,再用直线度综合塞规测量出塞规通过与否判断孔轴线直线度合格与否[7]。

其特点是:测量精度高,测量效率高,只能判断合格与否,不能得出数据大小。缺点是同一尺寸有时需要几个综合塞规,以满足1个公差段内几组尺寸的要求,适用于小孔测量。

2.2超声波测量法

超声波在同一种介质中传播时的声速为一常数,当遇到不同介质的界面时有反射特性,利用这一特性对已加工孔的壁厚进行测量,从而计算出孔轴线的直线度误差。其优点为:操作简单、实用性强。其测量精度主要与测厚仪显示值的分辨率有关,同时要求零件的外圆有较好的己加工表面[7]。

2.3光轴法

该法是以测微准值望远镜或自准值仪发出的光线为测量基线(即理想值线),测出被测直线相对于该理想直线的偏差量,再经数据处理求出被测线的直线度误差[7]。

2.4校正望远镜测量法

这种方法只能测量己加工好的大孔。其测量原理为:在各孔内安放与孔大小相适应的测标,调整望远镜位置使其光轴通过首位两孔的测标,建立测量基准线,然后移动各孔的测标到相应位置上,借助望远镜瞄准测量并测出各孔心的偏移量。校正望远镜是利用一个轴相对称的双像棱镜,是通过双像棱镜的光束形成两个相互垂直的校准平面,此两平面的交线就是望远镜的光轴。平行光透过扇形测标进入仪器,通过双像棱镜即可获得两个轴相对称的双像。如果测标中心完全与光轴重合,双像会靠拢形成一个完全对称的图像,称之为“合缝”,如果测标中心与光轴稍有偏差,双像就会分开,图像中间出现一道黑线或明亮的白线。调整测微仪使平行平晶偏转,光线通过偏转的平行平晶产生偏移,是双像重新“合缝”。通过测微器的移动,测出测标中心对光轴基准平面的位移量。

这种方法的优点为:(1)结构简单,操作方便,成本低廉,应用范围广,不受孔径限制;(2)瞄准和读数精度高;(3)由于各孔坐标及测量误差都是独立的,校正望远镜测量是对每个孔的测标瞄准读数,从而避免了累计误差[5]。

2.5 准直光管法

准直光管以“节距法”分段测量斜率变化,再通过数据处理求得实际表面的直线度误差,最后按规定条件评定直线度误差的数值。这种方法的特点是:测量精度高,可进行数字化处理,提高了测量效率和减少了人为误差,可测较长内孔和不同孔径的内径孔,但不适用于小孔径测量[5]。

2.6激光准直法

该法是以激光光束的能量中心线为直线基准,由光电位置敏感元件进行测量。其测量原理为:由氦一氖激光器发出的一束激光经准直后射向目标测量靶(可以在深孔中移动的测量元件),该靶中心有一块圆形四象限硅光电池,两两相对的硅光电池接成差动式。其中心与靶子的机械轴线重合。这样,上下一对硅光电池,可以用来测量靶子相对于激光束在垂直方向上的偏移;左右一对硅光电池,可用来测量靶子相对于激光束在水平方向上的偏移。

当光电接收靶中心与激光束能量中心重合时,相对的两个光电池接收能量相同,因此输出光电信号相等,无信号输出,指示电表指示为零。当靶子中心偏移激光束能量中心时,相对的几个光电池有差值信号输出,通过运算电路可用指示表指示出数值或

用纪录仪纪录下曲线。因此,测量时首先将仪器与靶子调整好,然后将靶子沿被测表面测量方向移动,便能得到深孔直线度误差的原始数据[6]。

该方法具有瞄准方便、测量效率高、测量精度较高和容易实现自动化等优点。由于激光的能量强,方向性和相干性好。因此,该方法可用于长距离测量。但是该方法的准直精度受激光光束本身特性的限制(如光束漂移、随机抖动等),如要求高精度,则需选用高稳定性的激光束。

2.7激光干涉、衍射法

用激光干涉法测量直线度,使直线度测量水平得到了很大提高。测量元件离开光路,再回到原来位置时,仪器能恢复原来的显示值。双频激光干涉仪。配上专用附件(渥拉斯顿棱镜和尾端双面反射镜),就可进行直线度测量。双频激光测量装置的共同特点是:(1)在以激光束为基准直线的基础上,采用干涉原理进行读数,提高了分辨率和精度。(2)该装置的测量原理和光学系统不受激光束漂移的影响。(3)该装置的各采样点误差值之间彼此不相关,测量误差不累加。总的说来,双频激光干涉仪精度高、使用方便、性能稳定,受到用户普遍欢迎。

激光衍射法测量直线度常用装置是一光栅作为敏感元件,以双面反射镜组两反射面夹角得平分线作为直线基准。基本原理同双频激光干涉仪的测量原理,只是用长光栅代替了渥拉斯顿棱镜。

激光技术的发展,使得我们可能采取措施提高激光能量的稳定性,克服激光光束本身的缺点如光束漂移、光束弯曲、随机扰动等,得到高稳定性,任意截面光强分布稳定的激光束,并以光电元件直接接收激光束能量中心的位置来做激光准直法直线度测量。近年来,半导体激光器(LD)的出现,克服了双频激光器价格昂贵、需要稳频的缺点,再加上新兴光电位置传感器(PSD)、电荷耦合器件(CCD)、四象限光电池等传感器性能的提高,使得一批新型激光准直直线度测量仪器渐渐被研制出来。它们分辨率较高,响应速度快,大多可以实现动态在线非接触直线度测量[2]。

2.8 基于图像处理的激光反射法测量

基于图像处理的激光反射法。测量时,激光器发出的激光经准直后射向分光镜,一部分反射后射向测量元件,测量元件在齿轮齿条机构的驱动下在孔管内移动,其步进量由光栅测量。测量元件感知孔管实际轴线位置的变化,其上安装一个反光镜,激光经过反射后透射过分光镜到达光靶上,CCD摄像机即可摄得光靶上包含被测信息的图像。再经过图像处理及数据处理后,得出对应于每一个被测截面的图像中激光光束的中心,按照角度积累的公式计算出空间直线度误差[8]。

此方法采用了光学反射放大的原理,其灵敏度比普通的激光准直法大大提高。同时,此法突破了普通激光准直法对被测对象孔径的限制,可以测量很小的深孔。另外,基于图像处理的方法使得测量过程自动化程度大大提高,从而提高了测量速度。该方法具有灵敏度高、测量速度快,对被测对象尺寸要求较低,适合在工厂内使用等优点。

3.小结

本文首先介绍了中北大学深孔直线度研究方面的成果;然后对深孔直线度误差的各种检测方法进行了详尽的论述,并对每种方法的优缺点进行比较分析。

参考文献:

[1] 王竣.现代深孔加工技术[M].哈尔滨:哈尔滨工业出版社,2005.

[2]宁磊,于大国,孟晓华.基于PSD 深孔钻削孔轴线在线检测方案探讨[J].组合机床与自动化加工技术,2013(12).

[3] 何定健,李建勋,王勇.深孔加工关键技术及发展[J].航空制造技术,2008(21) :90-97. [4] 沈兴全.深孔加工孔轴线的偏斜机理研究[J].中北大学学报(自然科学版), 2010, 46(4):31-34.

[5] 解海叶.深孔加工中存在问题的分析与处理[J].同煤科技,2011(2) :41—44.

[6] 马清艳,王彪,于大国.深孔直线度检测系统[J].机械设计与研究,2013,29(3):56-57. [7] 宁延平,刘战锋.国内外高精度直线度测量技术现状[J].现代制造工程,2005(6). [8]Amor Messaoud,Claus Weihs.Monitoring a deep hole drilling process by non- linear time series modeling[J].Journal of Sound and Vibration 321 (2009) 620-630.

同轴度测量方法[1]

同轴度测量方法 方法一:用两个相同的刃口状V 形块支承基准部位,然后用打表法测量被测部位。 1、测量器具准备:百分表、表座、表架、刃口状V 形块、平板、被测件、全棉布数块、防锈油等。 2、测量步骤 1)将准备好的刃口状V 形块放置在平板上,并调整水平。 2)将被测零件基准轮廓要素的中截面(两端圆柱的中间位置)放置在两个等高的刃口状V 形块上,基准轴线由V 形块模拟,如下图所示。 同轴度测量方法示意图 3)安装好百分表、表座、表架,调节百分表,使测头与工件被测外表面接触,并有1~2圈的压缩量。 4)缓慢而均匀地转动工件一周,并观察百分表指针的波动,取最大读数Mmax 与最小读数Mmin 的差值之半,作为该截面的同轴度误差。 5)转动被测零件,按上述方法测量四个不同截面(截面A 、B、C、D),取各截面测得的最大读数Mimax 与最小读数Mimin 差值之半中的最大值(绝对值)作为该零件的同轴度误差。 6)完成检测报告,整理实验器具。 3、数据处理 1)先计算出单个测量截面上的同轴度误差值,即Δ = (Mmax -Mmin )/2。 2)取各截面上测得的同轴度误差值中的最大值,作为该零件的同轴度误差。 4、检测报告 按步骤完成测量并将被测件的相关信息及测量结果填入检测报告单中,并检验零件的行为误差是否合格。 方法二:利用数据采集仪连接百分表测量法[1] 1、测量仪器:偏摆仪、百分表、数据采集仪 2、测量原理:数据采集仪会从百分表中自动读取测量数据的最大值跟最小值,然后由数据采集仪软件里的计算软件自动计算出所测产品的圆度误差,最后数据采集仪会自动判断所测零件的同轴度误差是否在同轴度范围内,如果所测同轴度误差大于同轴度公差值,采集仪会自动发出报警功能,提醒相关操作人员该产品不合格。测量效果示意图: 数据采集仪连接百分表测量同轴度误差示意图 优势:1)无需人工用肉眼去读数,可以减少由于人工读数产生的误差; 2)无需人工去处理数据,数据采集仪会自动计算出同轴度误差值。 3)测量结果报警,一旦测量结果不在同轴度公差带时,数据采集仪就会自动报警。

直线度测量方法

直线度测量方法 1、光电法测量 光电法测量是以三台测径仪为基础进行检测的,可以用于测量运动中的 线、棒、管的外轮廓的直线度。 布置上图的的设备3台,三台设备同一时刻测量被测工件的位置数据左边和右边两台采集的位置连线,计算出中间设备的在直线度为0时的理论位置,与中间一台所获的的位置数据比较,差值即为被测工件在当前位置的直线偏差如下图所示。

测量单元的测量频率为500-1000HZ,采用电子同步控制单元实现3 台设备的同步采样,可连续检测,根据检测数据模拟出整根线、棒(管)材的直线度,左、右两台的距离可根据具体情况确定安装位置。 2、自准直法 自准直法直线度检测仪可用于圆管外径的直线度检测。平行光仪器是 将和准直望远镜结合为一体的一台仪器。 光源将位于物镜焦平面(物镜焦距二f)的分划板投射至无穷远(准直 光出射),经过平面反射镜返回的准直光经物镜后再次成像于同样位

于物镜焦平面(共焦系统)的光电传感器的探测面上,当反射镜发生了a 角度的偏转后,返回的分划板在光电传感器上的像会产生AS的位移,通过精确测量出AS值,即可准确计算出平面反射镜的偏转角度。 检测内孔直线度时,将平面反射镜伸入孔内,利用胀套保证反射镜与内孔垂直。当内孔有弯曲时反射镜将偏转一定的角度,通过反射镜的偏转角度可以计算出内孔的直线度。 3、PSD芯片激光测量法 激光器安装在激光器座上,激光器座的尾部有4个螺钉可以对激光的 照射角度进行微调。其头部与定心套连接后插入炮管孔内。位置检测单元

的激光位敏传感器安装在传感器座内,传感器座的头部与定心套连接,尾部与推杆连接。通过手动推动推杆可以使位置检测单元在炮管内孔内移动。 激光器定心去 工作时激光器发射1束激光射向激光位敏传感器,传感器内的PSD 芯片监测接收到的激光能量中心位置。定心套用来保证传感器一直处于炮管内孔的中心位置。当炮管在检测位置出现弯曲时,PSD芯片上的激光能量中心坐标值将发生变化。位置检测单元的电源线和数据线通过推杆中心孔与控制柜连接。

直线度测量计算方法

1引言 在工程实际中,评定导轨直线度误差的方法常用两端点连线法和最小条件法。两端点连线法,是将误差曲线首尾相连,再通过曲线的最高和最低点,分别作两条平行于首尾相连的直线,两平行线间沿纵坐标测量的数值,通过数据处理后,即为导轨的直线度误差值;最小条件法,是将误差曲线的“高、高”(或“低、低”)两点相连,过低(高)点作一直线与之相平行,两平行线间沿纵标坐测量的数值,通过数据处理后,即为导轨的直线误差值。 最小条件法是仲裁性评定。两端点连线法不是仲裁性评定,只是在评定时简单方便,所以在生产实际中常采用,但有时会产生较大的误差。本文讨论这两种评定方法之间产生误差的极限值。 2误差曲线在首尾连线的同侧 测量某一型号液压滑台导轨的直线度误差,得到直线度误差曲线,如图1所示。由图可知,该误差曲线在其首尾连线的同侧。下面分别采用最小条件法和两端点连线法,评定该导轨直线度误差值。 (1)最小条件法评定直线度误差 根据最小条件法,图1曲线的首尾分别是低点1和低点2(低点1与坐标原点重合),用直a1a1线相连,如图2所示。通过最高点3作a1a1直线的平行线a2a2。

在a1a1和a2a2两平行线包容的区域,沿y轴测量的数值,经数据处理,即为该导轨的直线度误差值

δ最小法。 (2)两端点连线法评定直线度误差 根据两端点连线法,图1曲线的首尾也分别是曲线的两端点1和2,如图3所示。将曲线端点1和端点2,用直线b1b1相连,再通过高点作b1b1的平行线b2b2。在b1b1和b2b2两平行线包容的区域,沿y轴测量的数值,经数据处理,即为该导轨的直线度误差值δ两端点。 (3)求解两种评定方法产生的误差极限 由于是对同一导轨误差曲线求解直线度误差,图2中的“低点1”、“低点2”和“高点3”分别对应图3中的“端点1”、“端点2”和“高点3”,即直线 a1a1与直线b1b1重合,直线a2a2与直线b2b2重合,因此两种评定方法产生的误差值为零

平行度检测仪的设计方法

第28卷第4期长春理工大学学报 Vo l 128No 142005年12月 J ou rnal of Changchun Un i versit y of Science and T echnology Dec .2005 收稿日期:2005-08-12 基金项目:振兴东北老工业基地项目(04-02GG156) 作者简介:张立颖,女(1976-),硕士研究生,主要从事光学仪器装调方面的研究。 平行度检测仪的设计方法 张立颖 刘德尚 王文革 (中国科学院长春光学精密机械与物理研究所,长春 130031) 摘 要:国内现有的平行度检测方法和检测设备都是用于检测可见光的平行度。对于激光和红外平行度的精密检测,还没有一个好的检测方法。本文介绍了一种既可以检测可见光又可以检测激光、红外平行度的检测仪,并且论述了设计原理、装调方法以及精度的验证,其检测精度可以达到?2d 。关键词:平行度;激光;红外 中图分类号:TH74512 文献标识码:A 文章编号:1672-9870(2005)04-0033-03 Design of t he L ight Parallelis m Detector Z HANG L i y ing LIU D es hang WANG W enge (Changchun Instit u te o f Op tics ,F i n eM echanics and Phy sics ,Chinese Acade my of Siences ,Changchun 130031)Abst ract :In our nation ,w e have l o ts o f m ethods and equ i p m ents to detect the parallelis m of v isible li g h.t But w e don t 'kno w how to detect the paralle lis m of laser and i n frared ,This paper descri b es briefly the desi g n idea,asse m b l y techn i q ue and ho w to test and verify its accuracy .A t las,t we get the conclu -si o n that the accuracy of the ne w detecto r is less than ?2d ,and the dectctor can be used i n v isi b l e ligh.t K ey w ords :Pa ra lle lis m;Laser ;Infrared 随着激光与红外技术的发展,红外跟踪器和激光测距机已被广泛应用在现代化的光电经纬仪上。 然而令人遗憾是,对于激光、红外系统的平行度的标校却一直没有一个令人满意的方法,无奈人们只能在几十公里外制造一个红外目标,并把这个目标假设为无穷远光源来标校激光、红外系统的平行度,这个方法测量误差大,实现也困难。本文设计的平行度检测仪(以下简称检测仪)从根本上解决了这个难题,它的结构简单、成本低,既可以在实验室使用,又可以直接安装在红外跟踪车上,在外场随时标校激光、红外的平行度,同时它又可兼做红外目标模拟器,因此具有良好的市场前景。 1 检测仪的结构及检测原理 111 检测仪的结构 用于检测激光、红外平行度的检测仪的组成包括,光学部分:(1)衰减片;(2)平面镜组;(3)分光镜;(4)平行光管;(5)红外光源;(6)特 制耙面。机械部分:(1)导轨;(2)可移动支架。用于可见光测量时,只需把红外光源更换为普通光源,将特制耙面更换为普通星点板即可。112 检测仪的检测原理11211 检测仪的光学系统 检测仪的光学系统如图1所示。检测仪由A 、B 两个光路组成。激光经过(光路A )衰减片衰减后,从平面镜2的周围入射到分光镜上,经过平行光管汇聚到特制耙面上,使耙面发热形成红外光源,发射出的光经过平行光管后变成平行光,经过分光镜把光分成两束,一束(光路A )原路返回,一束(光路B)进入红外接收系统。11212 检测仪的工作过程 ①红外光源发射出的光经过特制耙面(此时耙面可以视为一个星点)通过平行光管变成平行光,再经过分光镜进入光路B ,并呈像在红外成像器的光轴中心。 ②激光测距机发出的激光通过光路A 最终汇

用水平仪测量导轨直线度的方法

用水平仪测量导轨直线度的方法 在机械维修专业中常用到水平仪,它是机床修理、调整、安装最常用的测量仪器之一,主要用于检测机床导轨直线度、工作台平面度等。下面我们来了解水平仪是怎样测量导轨直线度的。 机床工作台的直线移动精度,在很大程度上取决于床身导轨的直线度。但机床导轨一般比较长,往往难以用平尺、检验棒等作为基准测量导轨的直线度,这时可以用水平仪进行测量。其工作原理是:假设在被测导轨上有一条理想水平直线作为测量基准,再把被测导轨分成若干段,然后用水平仪分别测出各段相对于理想水平直线所倾斜的角度值,通过绘制坐标图来确定导轨与水平直线的最大误差格数,最后运用公式(△H=n I L)计算出导轨与水平直线的误差值。具体步骤如下: 1、将水平仪放在导轨中间,调平导轨,防止导轨倾斜,无法准确读出水平仪读数。 2、水平仪放在一定长度L)的平行桥板上,不能直接放置在被测表面上。 3、将导轨分段,每段长度与桥板相适应,依次首尾相接,逐段测量并记录下每段读数及倾斜方向。 4、根据各段读数画出导轨直线度曲线图:以导轨的长度为横坐标,水平仪读数为纵坐标。根据读数依次画出各折线

段,每一段的起点要与前一段的终点重合。 例如C6132 车床的导轨长 1600mm.用精 度为l000mm 的框式水平仪 测量导轨在垂直平面内直线度误差。水平仪桥板长度为200mm,分8段测量。每段读数依次为:+l、+1、+2、0、-1、-l、0、,如图1所示。 按一定比例画出纵横坐标,作出导轨直线度曲线。如图2所示。 5、用两端点连线法或最小区域法确定最大误差读数和误差曲线形状。 两端点连线法:若导轨直线度误差曲线呈单凸或单凹时,作首尾两端点连线I-I,并过曲线最高点或最低点)作Ⅱ-Ⅱ直线与I—I平行。两包容线间取大坐标值即为最人误差值。如图2所示,最大误差在导轨长为600mm处。曲线右端点坐标值为格,按相似三角形解法,导轨600mm处最大误差值为=格。 最小区域 法:如果直线 度误差曲线

测量同轴度误差的方法

测量同轴度误差的方法

一、同轴度 同轴度用于控制轴类零件的被测轴线对基准轴线的同轴度误差。 二、同轴度公差带 同轴度公差带是直径为公差值t,且与基准轴线同轴的圆柱面内的区域。如下图所示。?d孔轴线必须位于直径为公差值0.1mm,且与基准轴线同轴的圆柱面内。 三、任务:测量联动轴零件的同轴度误差 任务分析:被测项目是被测要素为大圆柱面的轴线,基准要素为两端小圆柱面的公共轴线。

含义:大圆柱面的轴线必须位于直径为公差值Φt(Φ0.08mm)的圆柱面内,此圆柱面的轴线与公共基准轴线A‐B(即 两个小圆柱面的公共轴线)重合。 根据含义可知,我们选择测量方法有两种。 四、测量方法 方法一: 用两个相同的刃口状 V 形块支承基准部位,然后用打表法测量被测部位。 1、测量器具准备 百分表、表座、表架、刃口状 V 形块、平板、被测件、全棉布数块、防锈油等。 2、测量步骤 1)将准备好的刃口状 V 形块放置在平板上,并调整水平。 2)将被测零件基准轮廓要素的中截面(两端圆柱的中间位置)放置在两个等高的刃口状 V 形块上,基准轴线由 V 形块模拟,如图 3-77 所示。

3)安装好百分表、表座、表架,调节百分表,使测头与工件被测外表面接触,并有1~2圈的压缩量。 4)缓慢而均匀地转动工件一周,并观察百分表指针的波动,取最大读数Mmax 与最小读数 Mmin 的差值之半,作为该截面的同轴度误差。 5)转动被测零件,按上述方法测量四个不同截面(截面 A 、B、C、D),取各截面测得的最大读数 Mimax 与最小读数 Mimin 差值之半中的最大值(绝对值)作为该零件的同轴度误差。 6)完成检测报告,整理实验器具。 3、数据处理 1)先计算出单个测量截面上的同轴度误差值,即Δ=(Mmax - Mmin )/2。 2)取各截面上测得的同轴度误差值中的最大值,作为该零件的同轴度误差。 4、检测报告 按步骤完成测量并将被测件的相关信息及测量结果填入检测报告单中,并 检验零件的行为误差是否合格。 方法二: 直接利用数据采集仪连接百分表实现高效测量 1、测量仪器:偏摆仪、百分表、太友科技QSmart 数据采集仪。 2、测量原理:数据采集仪会从百分表中自动读取测量数据的最大值跟最小值, 然后由数据采集仪软件里的计算软件自动计算出所测产品的同轴度误差(Δ=(Mmax - Mmin )/2),最后数据采集仪会自动判断所测零件的同轴度误差是否在同轴度公差范围内,如果所测同轴度误差大于圆度公差值,采集仪会自动发出报警功能,提醒相关操作人员该产品不合格。 测量效果示意图:

轨道直线度测量方法的综述

上海大学2014 ~2015 学年春季学期研究生课程考试 课程名称:现代光学测试技术课程编号: 09SAT9004 论文题目: 轨道直线度测量方法的综述 研究生姓名: 华明亚学号: 14721353 论文评语: 成绩: 任课教师: 高洪跃 评阅日期:

轨道直线度测量方法的综述 华明亚 (上海大学机电工程与自动化学院,上海200072) 摘要:随着我国铁路交通事业的快速发展,我国的铁路线路已经达到了2.4万公里。在高速铁路线路里程不断增加,列车大提速的背景下,随着使用年限的增加,在某些路段铁轨会发生弯曲、下沉等形变,从而导致平直度等参数超过建设初期的安全设计指标,会产生一系列事故隐患。为预防因线路老化问题带来的重大事故的发生,越来越多的线路需要人工进行检测和维护。在传统铁轨检测时,通常采用1Om弦测法或者大型轨检车进行测量,前者测量误差较大,有很大的局限性;后者价格昂贵,也不便于日常检修使用。因此,工程中需要较高精度,低成本,测量距离长,使用简便的铁轨直线度测量方法。本文介绍了三种简便而且应用比较成熟的轨道直线度测量方法,包括三坐标法,双频激光干涉仪测量法和激光准直测量法。并且简单阐述了它们的工作原理,优缺点,误差分析以及应用场合。 关键词:轨道测量;直线度;激光测量; Application of image processing technology Hua Mingya (School of mechanical engineering and automation, Shanghai University, Shanghai 200072, China) Abstract:With the rapid development of China's railway transportation, our railway line has reached 24000 kilometers. As high speed railway mileage increases, with the background of high speed train and the increase of age ,the track of some sections will bending and sinking deformation, which leads to the flatness of the parameters over at the initial stage of the construction safety design index and will produce a series of accidents. In order to prevent the occurrence of major accidents caused by the aging of the line, more and more lines need to be detected and maintained manually. In the traditional rail detection, usually with 10m chord measurement or large track inspection car are measured, the former measurement has many errors, which is a big limitation; the latter is expensive, not easy to daily maintenance. Therefore, the engineering need to high accuracy, low cost, long distance measurement, using simple rail straightness measurement method. This paper introduces three simple and more sophisticated methods for measuring the straightness of orbit, including three coordinate method, dual frequency laser interferometer and laser alignment. And it also describes their working principle, the advantages and disadvantages, the error analysis and the application. Key words: Orbit measurement;Laser measurement; Straightness; 1.引言 随着我国铁路交通事业的快速发展,普通铁路提速和建设高速铁路已经成为提高铁路运送能力的重要手段。至2007年底,我国铁路原有线路经过了六次大面积提速,快速线路长度达到2. 4万公里,其中允许速度160Km/h及以上的线路更是达到了1. 6万公里。随着列车运营速度的快速提高,也对铁轨自身的参数提出了更高的要求[1]。高速铁路要求轨道几何形位必须保持极高的平顺性,否则,轨面极小的形变都可能引起巨大的轮轨冲击力,造成轨道部件的损伤,更有甚者,可能会造成列车的脱轨等重大事故发生[2]。轨道状态的不平顺往

同轴度测量方法

同轴度测量方法 方法一: 用两个相同的刃口状V 形块支承基准部位,然后用打表法测量被测部位。 1、测量器具准备 百分表、表座、表架、刃口状V 形块、平板、被测件、全棉布数块、防锈油等。 2、测量步骤 1)将准备好的刃口状V 形块放置在平板上,并调整水平。 2)将被测零件基准轮廓要素的中截面(两端圆柱的中间位置)放置在两个等高的刃口状V 形块上,基准轴线由V 形块模拟,如下图所示。 同轴度测量方法示意图 3)安装好百分表、表座、表架,调节百分表,使测头与工件被测外表面接触,并有1~2圈的压缩量。 4)缓慢而均匀地转动工件一周,并观察百分表指针的波动,取最大读数Mmax与最小读数Mmin的差值之半,作为该截面的同轴度误差。 5)转动被测零件,按上述方法测量四个不同截面(截面A 、B、C、D),取各截面测得的最大读数Mimax与最小读数Mimin差值之半中的最大值(绝对值)作为该零件的同轴度误差。 6)完成检测报告,整理实验器具。 3、数据处理 1)先计算出单个测量截面上的同轴度误差值,即Δ = (Mmax-Mmin)/2。 2)取各截面上测得的同轴度误差值中的最大值,作为该零件的同轴度误差。 4、检测报告 按步骤完成测量并将被测件的相关信息及测量结果填入检测报告单中,并 检验零件的行为误差是否合格。 方法二:利用数据采集仪连接百分表测量法[1] 1、测量仪器:偏摆仪、百分表、数据采集仪 2、测量原理:数据采集仪会从百分表中自动读取测量数据的最大值跟最小值,然后由数据采集仪软件里的计算软件自动计算出所测产品的圆度误差,最后数据采集仪会自动判断所测零件的同轴度误差是否在同轴度范围内,如果所测同轴度误差大于同轴度公差值,采集仪会自动发出报警功能,提醒相关操作人员该产品不合格。测量效果示意图:

水泵机组同轴度的测量与校正

水泵机组同轴度的测量 与校正 Document serial number【UU89WT-UU98YT-UU8CB-UUUT-UUT108】

水泵机组同轴度的测量与校正 状元水厂项慧均 摘要:本文主要是根据状元水厂的水泵机组的特点,叙述联轴器的配合偏差、机泵同轴度测量误差产生的原因及解决方法、主要以叙述水泵机组同轴度的测量和校正方法为主。 关键词:配合偏差,同轴度,联轴器,轴向窜动,径向偏差,轴向偏差,不同心度,不平行度。 前言:水泵机组的同轴度是指水泵轴和电机轴的装配偏差,而联轴器是电机和水泵传动的联接部件,机泵的配合偏差也就是联轴器的配合偏差,联轴器装配后都存在着配合偏差,联轴器的配合偏差过大会造成水泵机组的振动增大,是影响轴承、联轴器损坏的主要原因,因此,为了减少水泵机组的振动,就必须减少联轴器的配合偏差,把偏差调整到允许的范围内,才能有效地保证机组的机械寿命,在机泵的运行过程中,因机组自身的振动或基础与管路的沉降等等原因都会造成联轴器配合偏差变化,所以定期对水泵机组同轴度的测量与校正是机泵维护中的重要项目。 一. 联轴器配合偏差的介绍。 联轴器配合的偏差有三种:径向偏差、轴向偏差、角向偏差,径向偏差是指联轴器的两个圆心之间的偏差,可用不同心度来表示,轴向偏差是指两配合面之间的距离与标准配合距离之间的偏差,同轴度测量中用联轴器的间距来表示,间距的测量较简单,用游标尺可直接测量出来,由于轴向偏差的精度要求较低(误差为±3mm),且基座的沉降或设备的振动基本上不影响间距的变化,即使偏差超值校正也简单,所以在同轴度测量中以

测量径向偏差和角向偏差为主,角向偏差是指联轴器两端面与平行端面的角度偏差,角向偏差可用机泵轴心的不平行度来表示,定义为在轴向的一米的距离上的与基准轴中心线的偏差值。由于习惯上把联轴器的角向偏差称为机泵同轴度中的轴向偏差,所以此本文也依照习惯在接下来叙述中把联轴器的角向偏差称为“轴向偏差”,联轴器的轴向偏差用联轴器的间距来表示。 二. 机泵同轴度测量的误差原因分析 状元水厂以前测同轴度的方法是习惯上用一只百分表对联轴器的径向和轴向进行测量,往往在同一时间里多次测量的值都存在较大的偏差,而且数值有时为正偏差有时为负偏差,即使后来用激光校正仪来测,在同一时间里多次测量的值都存在偏差,因测量值不准,就无法校正机泵的同轴度。经过分析发现:我厂的机泵联轴器是膜片式联轴器,在测量中时将联轴器转动180°时,水泵或电机有轴向窜动现象出现,每次测量时其轴向窜动量都是不同的,窜动量从几丝到几十丝的之间变化,所以机泵同轴度测量的误差主要是机泵的轴向窜动造成的,轴向窜动对径向偏差的测量影响微小,对轴向偏差的测量影响很大,为了消除轴向窜动对轴向偏差测量的误差,准确地测量出轴向偏差值,通过在CAD图形上进行模拟分析,发现如在测量轴向偏差是用两只相隔180°的百分表同时测量,就可以消除掉轴向窜动引起的测量误差,如下的图1就是模拟轴向窜动时测量轴向偏差的分析图形。 图1 三. 机泵同轴度的测量只要是测量径向偏差和轴向偏差,径向偏差和轴向偏差说明如下:

机床导轨直线度误差检测

实训十机床导轨直线度误差检测 一.实训目的 1、了解机床导轨直线度检测内容、原理、方法和步骤 2、掌握方框水平仪的使用方法 3、实训中测试数据的处理及误差曲线的绘制 二.实训设备 车床床身、方框水平仪、桥板 三.实训原理 直线度误差就是实际直线对其理想直线的变动量。直线度误差的评定方法有:1.最小包容区域法;2.最小二乘法;3.两端连线法。其中最小包容区域法的评定结果小于或等于其它两种方法。 在下图中,以最小包容区域线L MZ作为评定基线求得直线度误差f MZ的方法,就是最小包容区域法。对给定平面或给定方向的直线度误差f MZ,其计算方法:f MZ=f=d max-d min 式中d max、d min——检测中最大、最小偏离值,d i在L MZ上方取正值,下方取负值。 机床导轨直线度检测方法很多,有平尺检测、水平仪检测、自准仪检测、钢丝和显微镜检测等。本次实训用水平仪检测。 水平仪的刻度值有0.02/1000—0.05/1000,0.02/1000表示将该水 平仪放在1m长的平尺表面上,将平尺一端垫起0.02mm高时,平尺便倾斜一个α角,此时水平仪的气泡便向高处正好移动一个刻度值(即移动了一格)。水平仪和平尺的关系见下图

水平仪测量升(落)差原理图 tgα=ΔH/L=0.02/1000=0.00002 由于水平仪的长度只有200mm,所以tgα=ΔH1/L=ΔH1/200 ΔH1=200× tgα=200×0.00002=0.004mm 可见水平仪右边的升(落)差ΔH1与所用的水平仪规格有关,此外在实际使用水平仪也不一定是移动一格,例如移动了两格,水平仪还是200mm规格,则升(落)差ΔH1为 tgα=0.02×2/1000=ΔH1/200 ΔH1=200×0.02×2/1000=0.008mm 水平仪读数的符号,习惯上规定:气泡移动的方向和水平仪移动方向相同时,读数为正值,反之为负值。 四.实训步骤 1、检测床身前,擦净导轨表面将床身安置在适当的基础上,并基本调平。调平的目的是为了得到床身静态稳定性。 2、以200mm长等分机床导轨成若干段,将水平仪放置在导轨的左(右)端,作为检测工作的起点,记下此时水平仪气泡的位置,然后按导轨分段,首尾相接依次放置水平仪,记下水平仪每一段时气泡的位置,填入实训报告中。 3、作出实训报告。

三坐标测量仪同轴度测量的方法

三坐标测量仪同轴度测量的方法 作者:admin 来源:未知时间:2014-03-20 08:38 查看:1640次 摘要:同轴度是表示零件的有关要素(轴与轴、孔与孔、轴与孔之间)要求同轴,即控制实际轴线与基准轴线的偏离程度。公司内部有三坐标测仪的,建议使用三坐标测量仪进行测量,三坐 同轴度是表示零件的有关要素(轴与轴、孔与孔、轴与孔之间)要求同轴,即控制实际轴线与基准轴线的偏离程度。公司内部有三坐标测仪的,建议使用三坐标测量仪进行同轴度测量,三坐标是公认的测量空间形状误差较好的精密检测设备。 1、利用三坐标测量仪进行测量并直接评价出同轴度误差,有两种方法:一种是测量轴线与基准轴线直接评价法,而另一种是公共轴线法; 一些书中介绍的以一个孔建立一个基准轴线,而评价另个孔与基准的同轴度,由于测量孔和基准孔之间存在一定的距离,因此在评价时,测量误差就会被延长。通过三坐标测量验证,这种方法得出的数据是非常大的,而用这样的数据进行校对机床,反而产生了不良的效果,因此我们采用了用公共轴线法进行评价的方法,这种方法是比较适合生产现场和装配的实际情况的。 如用公共轴线法测量距离为L 的两个孔的同轴度,我们可以分别在两个孔测量两个截面圆,如果孔比较长的情况下,建议各孔均测出两个截面圆,用两个截面圆连线找出其中点即中间截面圆,两孔中间截面圆圆心连线建立公共轴线,把零点设在公共轴线上,这样公共基准就找好了,然后用刚刚测量的单个孔的两个截面圆连线,分别与公共轴线进行比较同轴度,取最大值为两孔同轴度的误差。如图 评价1、2 连线与公共轴线同轴度, 评价4、5 连线与公共轴线同轴度, 取最大差值为同轴度 如本例中就很按照图的规律用三坐标直接评价,在两个外圆上分别取截面圆,因其外 圆的长度很短,可直接取两端A、B 基准的一个截面圆心连线为公共轴线,在坐标系中并设 为零点,然后测量两端内孔后分别与公共轴线同轴度进行比较,测得 零件标记 1# 2# 3# 4# 5# 同轴度◎ 0.164 0.228 0.173 0.260 0.093 可以看出按客户0.15 的同轴度要求,只有5#合格(5#是由远离操作者那个轴加工的),1#、2#、3#、4#超差(靠近操作者的轴加工)。机床靠近操作者的轴应该调整。

用打表法测量阀体的平面度及平行度.doc

用打表法测量阀体的平面度和平行度的方法 一 实验目的 本实验所用测量方法是工厂里常用的方法,有助于学生对平面度公差、面对面的平行度公差概念的理解,训练学生的动手能力(仅一台三坐标测量机,做不到人人动手操作),训练学生数据处理能力,以及对平面度评定方法的理解。 二 实验仪器 测量平台,作为测量的基准使用,精度要求高。磁力表架和表座、千分表、V 型块、被测零件阀体。 三 操作过程 1 将磁力表架和V 型块放置于测量平台上,将被测零件阀体放置于V 型块上。 2 将千分表安装在磁力表架上,调整磁力表架,使千分表的测头与阀体的被测平面垂直接触,且具有一定的接触力,并保证测量过程中千分表不超量程。 3 固定磁力表座,推动V 型块,并保证其与测量平台稳定接触,使千分表测头与 测量平台 阀体 表架 表座 千分表 V 型块

被测平面上3X3分布的点接触,记录9个数据,如下所示。 四数据处理 1 误差评定准则(见教材) 将测得数据处理成上述三个准则中的任意一种,各点数据中的最大值减去最小值即为平面度误差。而平行度误差评定较简单,在测得原始数据中,用最大值减去最小值即是。 2 平面度数据处理方法(见学习指导) 测得数据不会是三个准则中的任意一种,需要进行处理才行,处理方法按照如下例题所示。 例用打表法测量一块350mmx350mm的平板,各测点的读数值如下图所示。试用最小包容区域法求平面度误差值。 解:此题旨在训练培养大家进行数据处理,求解几何误差的能力。观察检测数据,最大值为20,最小值为-12 ,次小值为-10,决定采用三角形准则求解平面度误差。保留中间的最大值,求出3个相等的最小值,三个最小值位置选定-12、-10、+7,将3个数值相加除3等于-5,即3个数的平均值。利用矩阵变换方法,将3个最小值变为-5,即将第1列的数都加+7,而将第三列的数都加-7,将结果列表后,再将第一行都加-5,而第三行都加+5,再将结果列表,即得下图所示。 经过两次坐标变换后,故平面度误差值为() f=+--= 205μm25μm

1).直线度和平面度

机 械 加 工 检 验 标 准 及 方 法.目的: .范围: 三.规范性引用文件 四.尺寸检验原则 1.基本原则: 2.最小变形原则: 3.最短尺寸链原则: 4.封闭原则: 5.基准统一原则: 6.其他规定 五.检验对环境的要求 1.温度 2.湿度 3.清洁度 4.振动 5.电压 六.外观检验 1.检验方法

2.检验目距 3.检测光源 4.检测时间 5.倒角、倒圆 7.伤痕 9.凹坑、凸起、缺料、多料、台阶10.污渍11.砂孔、杂物、裂纹12.防护包装

七.表面粗糙度的检验 1.基本要求 2.检验方法: 3.测量方向 4.测量部位 5.取样长度 八.线性尺寸和角度尺寸公差要求 1.基本要求2线性尺寸未注公差 九.形状和位置公差的检验 1.基本要求3.检测方法十?螺纹的检验 1.使用螺纹量规检验螺纹制件 2.单项检验 1^一 .外协加工件的检验规定 1.来料检验 2.成品检验计划十二.判定规则附注: 1.泰勒原则

.目的: 为了明确公司金属切削加工检验标准,使检验作业有所遵循,特制定本标准。 .范围: 本标准适用于切削加工(包括外协、制程、出货过程)各检验特性的检验。在本标准中, 切削加工指的是:车削加工、铣削加工、磨削加工、镗削加工、刨削加工、孔加工、拉削加 工和钳工作业等。本标准规定了尺寸检验的基本原则、对环境的要求、外观检验标准、线性 尺寸公差要求、形位公差要求、表面粗糙度的检验、螺纹的检验和判定准则。 注:本标准不适用于铸造、锻造、钣金、冲压、焊接加工后的检验,其检验标准另行制 定。本标准不拟对长度、角度、锥度的测量方法进行描述 ,可参看相关技术手册;形位公差 的测量可参看GB/T1958-1980;齿轮、蜗杆的检验可参看相关技术手册。 三.规范性引用文件 下列文件中的条款通过本标准的引用而成为本标准的条款。凡是注日期的引用文件,其随后 所有的修改单(不包括勘误的内容)或修订版均不适用于本标准,然而,鼓励根据本标准达 成协议的各方研究是否 可使用这些文件的最新版本。凡是不注日期的引用文件,其最新版 本适用于本 标准 计数抽样程序第1部分:按接收质量限(AQL )检索的 逐批检验抽样计划 GB/T 1958-1980 形状和位置公差 检测规定 GB/T 1957-1981 光滑极限量规 Q/HXB 3000.1抽样检查作业指导书 Q/HXB 2005.1产品的监视和测量控制程序 Q/HXB 2005.15不合格品控制程序 GB/T 2828.1-2003 (ISO 2859-1:1989) GB/T 1804- 2000 (ISO2768-1:104989) 一般公差未注公差的线性和角度尺寸的公差 GB/T 1184 - 1996(ISO2768-2:1989) 形状和位置公差未注公差值

长距离同轴度测量方法及实验

第18卷 第2期1997年4月 计 量 学 报ACTA METROLO GICA SIN ICA Vol.18,№2  April ,1997 长距离同轴度测量方法及实验 3 成相印 方仲彦 殷纯永 郭继华 (清华大学,北京 100084) 摘要 本文介绍了一种新型的自适应双频激光同轴度测量系统,该系统利用两个完全对称的渥拉斯顿棱镜,一个作为测量元件,另一个作为补偿元件。采用比相技术处理测量信号,因而测量元件可以暂时移出光路,能够进行同轴度的测量。系统的光学设计使激光光束的平漂和角漂不影响测量结果,对激光的漂移有自适应性。两束干涉光基本符合共光路原则,因而对大气湍流、空气扰动的影响具有更强的适应性,可用于长距离直线度、同轴度的测量。该系统与HP5528双频激光干涉仪在27m 的长导轨上进行了测量直线度的比对实验及挡光实验。比对实验结果表明,该系统在测量精度及稳定性上不低于HP5528。挡光实验表明,该系统挡光后,数据能够自动恢复,可用于同轴度的测量。 关键词: 直线度测量 同轴度测量 自适应系统 本文于1995-12-26收到,1996-10-16修改收到。3 国家自然科学基金资助项目 1 前言 激光在准直测量方面的应用十分广泛。利用双频激光干涉仪的直线度附件测直线度是其成功的范例,其光路如图1所示。该方案对于激光光束的平漂和角漂有自适应作用,测量精度 图1 双频激光测直线度原理图 高,工作稳定。传统的双频激光干涉仪在信号处理上采用锁相倍频计数技术,不允许光路信号中断,否则计数立即无效,因而HP5528等双频激光干涉仪不可能用于测量同轴度。 作者提出了一种新型的自适应双频激光准直系 统,该系统可以用于同轴度测量。本文介绍了该系统 的测量原理,并与HP5528测直线度系统进行了比对实验。 2 测量原理 同轴度测量系统原理如图2所示。双频激光头出射的正交线偏振光通过第一个渥拉斯顿棱镜W 1,分开一小角度,再通过第二个渥拉斯顿棱镜W 2后,变成两束平行光,经直角棱镜反射后,再依次通过W 2、W 1又变成一束光,经探测器D 2接收,形成测量信号。D 1输出的是参考

导轨直线度误差检测方法介绍

导轨直线度误差检测方法介绍

一、直经度的定义 限制实际直线对理想直线变动量的一种形状公差。由形状(理想包容形状)、大小(公差值)、方向、位置四个要素组成。用于限制一个平面内的直线形状偏差,限制空间直线在某一方向上的形状偏差,限制空间直线在任一方向上的形状偏差。 几何误差是指零件加工后的实际形状、方向和相互位置与理想形状、方向和相互位置的差异。在形状上的差异称形状误差,在方向上的差异称方向误差,在相互位置上的差异称位置误差。直线度在几何公差中是最基础的部分,按检测关系分直线度属于被测要素中的单一要素——指对要素本身提出形状公差要求的被测要素。 二、导轨直线度误差检测方法 直线度误差的检测方法很多。工件较小时,常以刀口尺、检验平尺作为模拟理想直线,用光隙法或间隙法确定被测实际要素的直线度误差。当工件较大时,则常按国标规定的测量坐标值原则进行测量,取得必要的一组数据,经作图法或计算法得到直线度误差,还有种高效的测量方法就是直接利用太友科技的数据采集仪连接百分表来测量,无需人工读数、作图、分析,采集仪会自动读数数据并进行数据分析,一旦测量结果不合格还会自动产生报警功能。 测量直线度误差常用的仪器有:框式水平仪、合象水平仪、电感式水平仪、自准直仪以及数据采集分析仪等。这类仪器的特点是:测定微小角度的变化,换算为线值误差。本实验用合象水平仪和数据采集分析仪来进行直线度测量。 1、利用合象水平仪测量直线度法 1)合象水平仪的介绍 合象水平仪采用光学放大,并以对称棱镜使双象重合来提高读数精度,利用杠杆和微动螺杆传动机构来提高测量精度和增大测量范围。将合象水平仪置于被测工件表面上,当被测两点相对水平线不等高时,将引起两气泡象不重合,转动度盘,使两气泡重合,度盘转过格数代表被测两点相对水平线的高度差,见图2-3。

轨道直线度误差的测量

轨道直线度误差测量 一、实验目的: 1、掌握用水平仪测量垂直平面内的直线度误差的方法。 2、掌握用作图法求直线度误差,用最小区域法评定直线度误差的方法。 3、了解其他测量直线度误差的方法。 二、实验内容: 测量导轨直线度误差或测量平板一对角线的直线度误差。 三、水平仪的结构、工作原理: 1、水平仪的结构 框式水平仪一般是制成矩形框架,它们互相垂直平行,下方框边的上面装有一个水准器(密封的玻璃容器),本实验用i=0.01mm/l000mm水平仪。 2、测量工作原理: 以自然水平面为测量基准。用节距法(又称跨距法)对被测直线进行逐段测量,得到各段的读数然后经过数据处理,就可以用作图法或计算法求出误差值。 四、测量时注意事项 1、使用水平仪要尽量避免人的体温对它的影响。 2、测好一段.应推动板桥向后一测量段滑进,等气泡完全静止下来再读数。水平仪置于板桥上是作为一整体使用,测量过程中二者之间尽量不要发生相对移动。 3、作图力求准确,比例恰当,图面清晰。

五、实验步骤 1.将水平仪、桥板擦干净,将被测面去毛刺并擦净。 2.初步调平被测表面(导轨、平尺、平板、工作台)。 3.用节距法测量。桥板节距由被测长度L划分成若干等分段确定,跨距一般为100~250mm。将水平仪置于桥板上,从一端开始,逐段测量,做到相邻两段首尾相接。为使所作误差曲线图为实际形状误差的一致性,我们从左向右逐段进行测量。第一段的起点称为原点,第一段的末点是第1点,测得的读数表示该段末点相对起点的升降,将水平仪读数记于实验报告相应栏目中,然后将桥板连同水平仪滑移至第二段,使第一段末点与第二段的起点相衔接,就可测得第二点的读数。依此类推,直至测量完毕。 4.对测得值进行数据处理,用作图法求直线度误差f_。 用分度值: i =0.01 mm/m的合象水平仪检测长导轨的直线度,桥板跨距为130mm.测量数据列于下表: 六、数据处理

机床导轨直线度的测量

机床导轨直线度测量 昆山高锋:李明 正在测量 Y轴平面 直线度 1、测量导轨平面直线度时镭射架设方式如上面照片所示; 平面直线度要求0.02mm以内,水平调整较好的情况下能达到0.01;

2、测量导轨侧边直线度时镭射架设方式如以上照片所示; 平面直线度要求0.01mm 以内,由于该侧边精度直接影响机床的直线度,因此要求较高; 侧边直线度 的测量

反射镜 3、反射镜安装于透镜后面,反射穿过透镜射过来的镭射光;

4、透射镜,镭射发射的光首先经过透射镜 ; 5、 镭射的架设,首先放置折射镜,放置如前面照片所示,标示面朝向要测量的平面,先不安装透射镜,在最近距离时先对好镭射光,再推动滑块后移,这时反射回来的光线会偏移这时用镭射机后面的微调左右上下调正,调整时不能调整平移和上发射光 回授光

下摇把,等到拉到最后面后,微调对好光,再移到最前面利用上下左右摇把调整对光,来回数次后在最远端镭射感应光是绿色及可加装透射镜如前面照片所示,再进行类似前面的调整,使光的强度在绿色区域即可;

上图数据设定的由来:(上图设定已经过核对) 脚间距:设定200mm 测量导轨时要先用彩色白板笔划线给导轨分段,用滑块一般为200mm长,划线并编上序号,编序号的目的是在测量后发现有问题段时,可以根据序号的对应很快对应到问题段; 导轨长度:设定=脚间距×分的段数 如:导轨以200分段后分出26段,其导轨长度设定就是200mm ×26段=5200mm 测站:数值由脚间距和导轨长度自动生成 测量时的操作步骤: 1、先用200长滑块给机床导轨分段,分段由架设镭射机一边 开始分段并编上序号,至导轨另一端结束,并记录最后号数; 2、摆放镜头并对镭射光; 3、设定镭射软件参数;