型式试验报告模板
型式试验报告模板

1.试验项目及结论Order Test Type Testing Date Test Results 1 Conducted Emission Test 11.29 PASS2 Immunity to Continuous ConductedInterference Test11.29 PASS3 Radiated Emission Test(30MHz ~ 1000MHz)11.29 PASS4 Immunity To Radiated Electric Fields Test 11.29 PASS5 Electrical Fast Transient/Burst Immunity Test11.29 PASS6 Surge Immunity Test 11.29 PASS7 Voltage Dips, Short Interruptions and VoltageVariations Immunity Test11.30 PASS8 Voltage fluctuation and Flicker Test 11.30 PASS9 Harmonic Current Emissions Test 11.30 PASS10 Electrostatic Discharge Immunity Test 11.30 PASS 2. Mode of operation during the testConducted Emission Test:Mode1:Norma l Operation(DC 48V)Mode2: Norma l Operation(AC 220V/50Hz)Immunity to Continuous Conducted Interference Test:Mode1:Norma l Operatio nRadiated Emission Test(30MHz ~ 1000MHz):Mode1: Normal OperationImmunity To Radiated Electric Fields Test:Mode1:Norma l Operation(DC 48V)Mode2: Norma l Operation(AC 220V/50Hz)Electrical Fast Transient/Burst Immunity Test:Mode1:Normal Operation(DC 48V)Mode2: Normal Operation(AC 220V/50Hz)Mode2: Normal Operation(AC 220V/50Hz)Voltage Dips, Short Interruptions and Voltage Variations Immunity Test: Mode1:Normal Operation(DC 48V)Mode2: Normal Operation(AC 220V/50Hz)Voltage fluctuation and Flicker Test:Mode1:Normal Operation(DC 48V)Mode2: Normal Operation(AC 220V/50Hz)Harmonic Current Emissions Test:Mode1:Normal Operation(DC 48V)Mode2: Normal Operation(AC 220V/50Hz)Electrostatic Discharge Immunity Test:Mode1:Normal Operation1. Conducted Emission Test1.1. Conducted Emission Test Data and ResultsTes t Mod e : Mod e 1: Norma l Operation(D C 48V)DC Power : DC 48V Phase : LINE Temperature : 23°C Humidity : 52% Pressure(mbar) : 1002 Date: 2014/11/29No. Frequenc y(MHz) Facto r(dB)Readin g(dBuV)Leve l(dBuV)Limi t(dBuV)Margi n (dB)Detector1 0.1580 10.19 31.79 41.98 65.56 -23.58 QP2 0.1580 10.19 13.69 23.88 55.56 -31.68 AVG3 0.4460 10.27 29.01 39.28 56.95 -17.67 QP4 0.4460 10.27 22.69 32.96 46.95 -13.99 AVG5 1.0820 10.33 21.25 31.58 56.00 -24.42 QP6 1.0820 10.33 14.59 24.92 46.00 -21.08 AVG7 7.9860 10.54 20.34 30.88 60.00 -29.12 QP8 7.9860 10.54 19.57 30.11 50.00 -19.89 AVG9 15.9740 10.67 17.82 28.49 60.00 -31.51 QP10 15.9740 10.67 14.68 25.35 50.00 -24.65 AVG11 29.9300 10.84 17.79 28.63 60.00 -31.37 QP12 29.9300 10.84 16.09 26.93 50.00 -23.07 AVG Note: Measuremen t Leve l = Readin g Leve l + Correc t Facto rTes t Mod e : Mod e 1: Norma l Operation(D C 48V)DC Power : DC 48V Phase : NEUTRALTemperature : 23°C Humidity : 52%Pressure(mbar) : 1002 Date: 2014/11/29No. Frequenc y(MHz) Facto r(dB)Readin g(dBuV)Leve l(dBuV)Limi t(dBuV)Margi n(dB)Detector1 0.1539 9.86 31.22 41.08 65.78 -24.70 QP2 0.1539 9.86 13.69 23.55 55.78 -32.23 AVG3 0.4420 9.87 28.05 37.92 57.02 -19.10 QP4 0.4420 9.87 21.34 31.21 47.02 -15.81 AVG5 1.0980 9.90 21.36 31.26 56.00 -24.74 QP6 1.0980 9.90 13.40 23.30 46.00 -22.70 AVG7 7.9860 10.09 20.59 30.68 60.00 -29.32 QP8 7.9860 10.09 19.79 29.88 50.00 -20.12 AVG9 15.9780 10.18 12.82 23.00 60.00 -37.00 QP10 15.9780 10.18 7.32 17.50 50.00 -32.50 AVG11 29.4580 10.31 20.36 30.67 60.00 -29.33 QP12 29.4580 10.31 18.16 28.47 50.00 -21.53 AVG Note: Measuremen t Leve l = Readin g Leve l + Correc t Facto rTes t Mod e : Mod e 2: Norma l Operation(A C 220V/50Hz)DC Power : AC 220V/50Hz Phase : LINETemperature : 23°C Humidity : 52% Pressure(mbar) : 1002 Date: 2014/11/29No. Frequenc y(MHz) Facto r(dB)Readin g(dBuV)Leve l(dBuV)Limi t(dBuV)Margi n (dB)Detector1 0.1500 10.13 33.31 43.44 65.99 -22.55 QP2 0.1500 10.13 20.60 30.73 55.99 -25.26 AVG3 1.1180 10.16 23.34 33.50 56.00 -22.50 QP4 1.1180 10.16 16.56 26.72 46.00 -19.28 AVG5 1.5220 10.17 21.37 31.54 56.00 -24.46 QP6 1.5220 10.17 14.94 25.11 46.00 -20.89 AVG7 7.9900 10.25 15.67 25.92 60.00 -34.08 QP8 7.9900 10.25 12.28 22.53 50.00 -27.47 AVG9 15.9780 10.49 14.42 24.91 60.00 -35.09 QP10 15.9780 10.49 8.36 18.85 50.00 -31.15 AVG11 23.9580 10.41 22.71 33.12 60.00 -26.88 QP12 23.9580 10.41 21.01 31.42 50.00 -18.58 AVG Note: Measuremen t Leve l = Readin g Leve l + Correc t Facto rTes t Mod e : Mod e 2: Norma l Operation(A C 220V/50Hz)DC Power : AC 220V/50Hz Phase : NEUTRAL Temperature : 23°C Humidity : 52% Pressure(mbar) : 1002 Date: 2014/11/29No. Frequenc y(MHz) Facto r(dB)Readin g(dBuV)Leve l(dBuV)Limi t(dBuV)Margi n(dB)Detector1 0.1500 10.13 32.58 42.71 65.99 -23.28 QP2 0.1500 10.13 19.63 29.76 55.99 -26.23 AVG3 1.1420 10.18 24.80 34.98 56.00 -21.02 QP4 1.1420 10.18 17.43 27.61 46.00 -18.39 AVG5 7.9860 10.26 17.78 28.04 60.00 -31.96 QP6 7.9860 10.26 15.55 25.81 50.00 -24.19 AVG7 15.9780 10.51 16.77 27.28 60.00 -32.72 QP8 15.9780 10.51 13.07 23.58 50.00 -26.42 AVG9 23.9660 10.36 21.20 31.56 60.00 -28.44 QP10 23.9660 10.36 14.52 24.88 50.00 -25.12 AVG11 28.4940 10.29 17.12 27.41 60.00 -32.59 QP12 28.4940 10.29 14.45 24.74 50.00 -25.26 AVG13 0.1500 10.13 32.58 42.71 65.99 -23.28 QP14 0.1500 10.13 19.63 29.76 55.99 -26.23 AVG Note: Measuremen t Leve l = Readin g Leve l + Correc t Facto rTes t engineer:1.2. Conducted Emission Test Set-upDC 48VAC220V/50Hz2. Immunity to Continuous Conducted Interference Test2.1 Immunity to Continuous Conducted Interference Test Data and ResultsBasic Standard : GB/T 17626.5-2008Product Standard : EN 61000-6-2Final Test Result : PASSCoupling mode : CDN-(M2+M3) for DC power portsTemperature : 21°CRelative Humidity : 51%Atmospheric Pressure : 100 kPaTest Date : 2014.11.29Test Mode 1Frequency : 0.15~80MHz, Modulation : AM 80%,1KHz sine wave, Dwell time: 3sFrequency Step Size : 1 % of preceding frequency valuemode Voltage(V) Result Frequency Test0.15 ~ 80MHz Power(M2) 10 ATes t engineer:2.2.Immunity to Continuous Conducted Interference Test Set-up3. Radiated Emission Test(30MH z ~ 1000MHz)3.1.Radiated Emission Test Data and ResultsTes t Mod e : Mod e 1: Norma l Operatio nDC Power : DC 48V Ant. Polarization: Horizontal Temp : 23℃ Humidity : 52%Pressure(mbar) : 1002 Date : 2014/11/29No. Frequenc y(MHz) Facto r(dB/m)Readin g(dBuV)Leve l(dBuV/m)Limi t(dBuV/m)Margi n(dB)Det. Heigh t(cm)Azimut h(deg)1 189.0800 -18.19 46.32 28.13 40.00 -11.87 peak 200 1312 298.6899 -16.73 40.94 24.21 47.00 -22.79 peak 100 2043 364.6499 -15.10 38.09 22.99 47.00 -24.01 peak 200 24 445.1600 -13.53 38.68 25.15 47.00 -21.85 peak 100 2885 583.8700 -11.69 40.08 28.39 47.00 -18.61 peak 100 556 668.2599 -10.16 34.41 24.25 47.00 -22.75 peak 200 216 Note: Measuremen t Leve l = Readin g Leve l + Correc t Facto rTes t Mod e : Mod e 1: Norma l Operatio nDC Power : DC 48V Ant. Polarization: Vertical Temp : 23℃ Humidity : 52% Pressure(mbar) : 1002 Date : 2014/11/29No. Frequenc y(MHz) Facto r(dB/m)Readin g(dBuV)Leve l(dBuV/m)Limi t(dBuV/m)Margi n(dB)Det. Heigh t(cm)Azimut h(deg)1 47.4600 -18.33 45.98 27.65 40.00 -12.35 peak 100 3442 72.6800 -26.39 52.58 26.19 40.00 -13.81 peak 100 173 189.0800 -18.04 51.62 33.58 40.00 -6.42 peak 100 1344 302.5700 -16.47 39.53 23.06 47.00 -23.94 peak 100 1345 366.5900 -15.02 40.04 25.02 47.00 -21.98 peak 200 2896 584.8400 -11.76 41.09 29.33 47.00 -17.67 peak 100 148 Note: Measuremen t Leve l = Readin g Leve l + Correc t Facto rTes t engineer:3.2. Radiated Emission Test Set-upAC220V/50Hz4.Immunity To Radiated Electric Fields TestStandar d Fina l Tes t Resul t: EN61000-4-3: 2006 Fina l Tes t Resul t: PAS STest Voltage:80M~2GHz,10 V/m Temperatur e: 23°CRelativ e Humidit y: 55%Atmospheri c Pressur e: 100 kP aTes t Dat e: 2014.11.29Frequency (MHz)AntennaPolarizationTest fieldstrengthResult Remark80 MHz to 1 GHz Vertical 10 V/m PASS Criterion A 80 MHz to 1 GHz Horizontal 10 V/m PASS Criterion A 1.4 GHz to 2 GHz Vertical 10 V/m PASS Criterion A 1.4 GHz to 2 GHz Horizontal 10 V/m PASS Criterion ATes t engineer:5. Electrical Fast Transient/Burst Immunity TestBasi c Standar d : GB/T 17626.42008Fina l Tes t Resul t : PAS S O n D C Por t ±2.0 KvTes t Voltag e :Temperatur e : 21°CRelativ e Humidit y : 51 %Atmospheri c Pressur e : 100 kP aTes t Dat e : 2014.11.29Mode1:Puls e : 5/50 n sRepetitio n Rate: 5 kHz Burst 15m/300msTest time 1 min/each conditionVoltage/ Mode/ Polarity/ Result/ Phas e 1.0 kV 2.0 kV+ -+ -D C Powe r Lin eL(+)-- -- A A N (-)‐‐‐‐ A A L(+)-N (-)‐‐‐‐ A A P E ‐‐‐‐ A A L(+)-P E ‐‐‐‐ A A N (-)-P E‐‐‐‐ A A O n D C Por t ±2.0 K vO n A C Por t ±4.0 K vL(+)-N (-)-P E‐‐‐‐ A A Note: + fo r anode, fo r cathod eMode 2Puls e : 5/50 n sRepetitio n Rate: 5 kH zBurst : 15m/300msTest time : 1 min/each conditionVoltage/ Mode/ Polarity/ Result/ Phas e2.0 kV 4.0 kV + +A C Powe r Lin eL - A A-N A A LN A A PE A A LPE A A N PE A A L NPE A ACerpas s Technolog y (Suzhou) Co., Lt d Issue d Dat e : No v 30.2014Tes t engineer:6.Surg e Immunit y Tes t6.1 Surge Immunity Tes t Data and ResultsBasi c Standar d Produc t: GB/T 17626.5.2008 Standar d Fina l Tes t Resul t: EN6100062Fina l Tes t Resul t: PAS STes t Voltag e: Input DC Power Port -- ±2.0kV for Line to Line, ±4.0Kvfor Line to GNDInput AC Power Port -- ±4.0kV for Line to Line, ±6.0Kvfor Line to GNDTemperatur e: 21°C Relativ e Humidit y: 51 % Atmospheri c Pressur e: 100 kP a Tes t Dat e: 2014.11.29Mode 1: Normal Operation(DC 48V)Waveform : 1.2/50μs(8/20μs) Repetition rate : 60 sec Time : 20 time/each condition/Phase Voltage / Mode / Polarity Result2.0 kV L(+)-N(-)+ A- A4.0 kV L(+)-PE+ B- BN(-)-PE+ B- BMode 2: Normal Operation(AC 220V/50Hz)Waveform : 1.2/50μs(8/20μs) Repetition rate : 60 sec Time : 20 time/each condition/Phase Voltage / Mode / Polarity Result4.0 kV L-N+ A- A6.0 kV L-PE+ B- B+ BN-PE- BTes t enginee r6.2 Surge Immunity Tes t Set-up7.Voltage Dips, Short Interruptions and Voltage Variations Immunity TestStandar d Fina l Tes t Resul t: EN61000-4-11:2004Fina l Tes t Resul t: PAS STest Port:AC Power PortsTemperatur e: 20°C Relativ e Humidit y: 50% Atmospheri c Pressur e: 100 kP a Tes t Dat e: 2014.11.30Voltage Dips Test level (%residual voltage) Duration(ms)Minimumrequirement Result100 10 Criterion A Criterion A Pass 100 50 Criterion A Criterion A Pass30 500 Criterion B Criterion A PassVoltage InterruptionTest level (%residual voltage) Duration(s)Minimumrequirement Result0 5 Criterion C Criterion C PassTes t engineer:8. Voltage fluctuation and Flicker TestStandar d Fina l Tes t Resul t: GB 17625.2Fina l Tes t Resul t: PAS STemperatur e: 24°CRelativ e Humidit y: 53%Atmospheri c Pressur e: 101kP aTes t Dat e: 2014.11.30Uncertainty of FlickerExpanded uncertainty (k=2) of flicker measurement is ± 0.030 %Tes t engineer:9. Harmonic Current Emissions TestStandar d Fina l Tes t Resul t: GB 17625.1 Fina l Tes t Resul t: PAS S Temperatur e: 20°CRelativ e Humidit y: 50% Atmospheri c Pressur e: 100 kP a Tes t Dat e: 2014.11.30Order Av. Current[A] Frame:2.5min Limit In/I1 (%) Result1 0.0978 1.0800 0.738% PASS2 0.1878 2.3000 1.417% PASS3 0.0293 0.4300 0.221% PASS4 0.0409 1.1400 0.308% PASS5 0.0302 0.3000 0.228% PASS6 0.0348 0.7700 0.262% PASS7 0.0299 0.2300 0.226% PASS8 0.0363 0.4000 0.274% PASS9 0.0259 0.1840 0.195% PASS10 0.0382 0.3300 0.288% PASS11 0.0206 0.1533 0.155% PASS12 0.0388 0.2100 0.293% PASS13 0.0164 0.1314 0.124% PASS14 0.0415 0.1500 0.313% PASS15 0.0128 0.1150 0.097% PASS16 0.0426 0.1324 0.321% PASS17 0.0104 0.1022 0.078% PASS18 0.0389 0.1184 0.293% PASS19 0.0078 0.0920 0.059% PASSOrder Av. Current[A] Frame:2.5minLimit In/I1 (%) Result21 0.0401 0.1071 0.302% PASS22 0.0059 0.0836 0.045% PASS23 0.0333 0.0978 0.251% PASS24 0.0057 0.0767 0.043% PASS25 0.0346 0.0900 0.261% PASS26 0.0051 0.0708 0.038% PASS27 0.0328 0.0833 0.247% PASS28 0.0053 0.0657 0.040% PASS29 0.0277 0.0776 0.209% PASS30 0.0041 0.0613 0.031% PASS31 0.0255 0.0726 0.192% PASS32 0.0046 0.0575 0.035% PASS33 0.0226 0.0682 0.170% PASS34 0.004 0.0542 0.030% PASS35 0.0203 0.0643 0.153% PASS36 0.0036 0.0511 0.027% PASS37 0.0158 0.0608 0.119% PASS38 0.0036 0.0484 0.027% PASS39 0.0138 0.0577 0.104% PASS40 0.004 0.0460 0.030% PASSTes t engineer:10.Electrostatic Discharge Immunity Test10.1. Electrostatic Discharge Immunity Test Data and ResultsStandar d Fina l Tes t Resul t: GB/T 17626.2-2006Fina l Tes t Resul t: PAS STes t Voltag e: ±8kV Contact±15kV AirTemperatur e: 25°CRelativ e Humidit y: 50%Atmospheri c Pressur e: 100 kP aTes t Dat e: 2014.11.30Contact Discharge Air Discharge25 times / each 10 times / eachVoltage 2 kV 4 kV 6 kV 8 kV 2 kV 4 kV 8 kV 15 kV-+ -+ -+-+-+-+ -+ -Point\Polarity +------------A A---------------------------HCP ------------------A A---------------------VCP ------------------------------A A------------ 1,3,4,5,6 ---------------B B------------ --- --- ---------2,7,8,9,10,11,12 ------------------------A A---------------------14 ---13,15,16,17,18,22,23,24 --- --- --- ---------B B------------ --- --- ------------------A A--------------------- 19,20,21 ---------25,26,27,28,29,30,31,32 --- --- --- ---------B B------------ --- --- ------33,34,35,36,37,38 ------ --- ---------B B------------ --- --- ------39,40,41,42,43 B B49 ------ A A44,45,46 B B47,48 A A50,51,52,53 B B54,55 A A56,57 A B58,59,60 A A61,62,63 A ATes t engineer:10.2. Electrostatic Discharge Immunity Test Set-up。
安全型式试验报告

器具的型号、规格
Ⅱ类结构的符号(对Ⅱ类器具)
IP代码(IPX0不标出)
设计由用户来充液的加热器应标有最高和最低液位(GB4706.23-2003)
除了高位安装和可见发光的辐射式加热器外,其余应标警告用语“禁止覆盖”,除非其结构能保证其不被覆盖
(GB4706.23-2003)
设计用于干衣并符合IEC60335-2-43的加热器不要求该标志(GB4706.23-2003)
在运输或储藏时设计拆掉防火保护罩的加热器应标有警告用语(GB4706.23-2003)
7.2 对于用多种电源的驻立式器具的警告语
此警告语应位于接线端子罩盖的附近
7.3 正确地标示额定值围
7.4 不同额定电压的设定应清晰可辨
7.5 标出每个额定电压所对应的额定输入功率
标出额定输入功率的上、下限值
7.6 正确使用符号
7.7 配备正确的接线图,并固定在器具上
7.8 除Z型连接以外:
—专门连接中线的接线端子用字母N标明
—接地端子用符号标明
—标志不应设置在可拆卸的部件上
—应标出单极保护装置的对应接线端子
7.9 可能引起危险的开关的标志或放置
7.10 开关和控制器应用数字、字母或其它方式表示
数字“0”只能表示“断开”档位,除非不致引起与“断开”
档位相混淆
7.11 控制器应标出调节方向
7.12 使用说明(书)应随器具一起提供,以保证器具能安全使用。
型式试验报告

陈炳佳
完成日期
2012.03.22
样品数量
6 PCS
1105x327x300mm
东莞市瑞兴纸制品有限公司
实验目的
对新产品进行型式试验正其质量符合性。
实验要求
主要按型式试验规范。
检
样品的型试实验与检验时应根据以下相关的国家标准内容要求进行试验与检验测试,并依据标准试验结果进行判定:
验
依
1、堆码试验(抗压测试)。
2、跌落仪测试(垂直冲击跌落试验)。
据
3、边压测试。
4、耐破测试。
东莞市瑞兴纸制品有限公司
试验项目及试验结果
序号
检测项目
检测技术标准要求
检测结果描述
单项判定
1
堆码试验
该试验为合格
符合要求
合格
2
垂直冲击跌落试验
该试验为合格
符合要求
合格
3
边压
该试验为6000(N/M)
符合要求
合格
4
耐破
该试验为1200kpa
符合要求
合格
5
水份
该试验为合格
符合要求
合格
东莞市瑞兴纸制品有限公司
型式试验报告
备注(试验次数)
■第一次□第二次□第三次室温在20°C
抄报部门
■生产部□采购部■技术部■品管部□客户□其它
抄送人员
刘先领、黄周正、周真理
试验人员
审核
批准
供应商名称
理文、玖龙
接样日期
2012.03.20
测试日期
2012.03.20
抽样方式
彩箱
规格/型号
990x410x780mm
型式试验报告

编号: 特种设备型式试验报告
设备型式_______________________ 型号规格_______________________ 制造单位_______________________ 委托单位_______________________
(检验检测机构授权名称)
(检验检测机构授权名称)型式试验报告
注意事项
1. 报告无“检验专用章”或型式试验检验检测机构公章无效;报告无加盖骑缝章无效。
2. 复制报告未重新加盖“检验专用章”或型式试验检验检测机构公章无效;复制报告未重新加盖骑缝章无
效。
3. 报告无主检、审核、签发人签字无效。
4. 报告涂改无效。
5. 报告是对设备型式的确认,对样品本身的合格与否负责,且仅对符合送样样品的产品有效。
报告附加说明
1. 委托单位地址、电话:
2. 制造单位地址、电话:
3. 试验地点:
4. 样品情况:
5. 样品接受日期:
样品试验日期:
6. 试验项目有无外包:
7. 型式试验检验检测机构地址、电话:。
型式试验报告模板

符合要求
各项功 能正常。
最大输入 1、 实际测量最 大输入功率 值应小于 1 0%标称额定功 率值。 5 功 率测定 2、 实际测量最 小输入功率 值应大于 9 1%标称额定功 率值。
符合要求(见附 表数据 )
6
定时功能
1、 用火锅最大档进行加热,按定时键设定要求的最 长时间,实测的预约 时间应在设 定时间的±15 分钟内,且在工 作过程中无任何和异常现象 。
CSC/T26-2004《电磁灶节能 认证要求》
GB 1019《家用电器包 装通则》
检
GB 2423.1 电工电子产品基本环境 试验规程 试验 A:低温试验方 法 GB242 3.2 电工电子产品基本环境 试验规程 试验 B:高温试验方 法
验
GB242 3.3 电工电子产品基本环境 试验规程 试验 Ca:恒定湿热试 验方法
26
煮粥功能
1、分别在 25 0V、220V、180V 电压下,以 1 杯米 1 0 杯水试验,通过目视和 口尝检查煮 粥效果应符 合要求,无夹 生,无严重溢出 ,过程中无任何异常现象程序结束后 效果完好。
1、分别在 25 0V、220V、180V 电压下,分别用最大 、中等和最小 米量,加入相应刻 度水量进行 实际煮饭,通过
1、 在标准条件下使用标准锅具测试的最大输入功 率值应为:±10%P(额定功率);
24
锅具对比 2、 在标准条件下使用其它锅具测试的最大输入功 率值应为:±15%P(额定功率)。
25
煲汤功能
1、 分别在 25 0V、220V、180V 电压下,以 1 杯绿豆 10 杯水进行试验,煮好的汤应 味道鲜美,水分散失在 最长煲汤 时 间内不大于 30%,煲汤过程中 ,没有汤水明 显溢出现象 ,过程中无任何异常现象程序结束后 效果完好。
型式试验报告

c)本单元主母线额定短路耐受强度为:15kA;
d)本单元系列的短路耐受强度验证,开关柜结构形式与送试样品相同
e) 本单元系列主进线开关类型:隔离开关熔断器组、塑壳断路器
3
氧化锌避雷器
HY1.5W-0.5/2.6
3
西安低压电瓷厂
4
熔断器
RT1863A
36
人民电器集团有限公司/2003010308091325
5
接触器
CJ19-63
12
上海德力西开关有限公司/2003010304068650
6
热过载继电器
JR36-63
12
人民电器集团有限公司/2002010309013276
型号解释:
GGJ
(1)
(1)无功功率补偿柜
产品描述
4.特殊结构说明(如有需要):/
产品描述
5.产品认证情况:
6.安全件一览表:
序号
组件/部件名称
组件/材料
名称
型号规格/牌号
制造商(生产厂)
3C证书编号
1
断路器
塑壳式断路器
RDM1、DZ20Y系列
人民电器集团有限公司
DM1-100L、DZ20Y系列
佛山市一度电气有限公司
40×4
40×4
30×3
30×3
30×3
30×3
母线绝缘框规格(mm)
50×5
40×6
40×5
40×4
30×3
30×3
30×3
30×3
电气型式试验报告
电气型式试验报告
电气型式试验报告
一、试验目的
本次试验旨在对电气设备进行型式试验,验证其符合相关标准和规定要求,保证其安全可靠性。
二、试验对象
本次试验对象为某型号电气设备,包括电源、控制器、传感器等。
三、试验内容
1. 绝缘电阻试验:在试验电压下,测量设备的绝缘电阻,验证其是否符合标准要求。
2. 高压试验:在试验电压下,对设备进行高压试验,验证其绝缘性能是否符合标准要求。
3. 耐电强度试验:在试验电压下,对设备进行耐电强度试验,验证其
是否能够承受额定电压下的电压冲击。
4. 接地电阻试验:测量设备的接地电阻,验证其是否符合标准要求。
5. 电气安全试验:对设备进行电气安全试验,包括漏电保护、过载保护、短路保护等,验证其是否符合标准要求。
四、试验结果
经过以上试验,本次试验对象的各项指标均符合标准要求,证明其具有良好的安全可靠性。
五、结论
本次电气型式试验结果表明,本次试验对象的各项指标均符合标准要求,证明其具有良好的安全可靠性,可以投入使用。
六、建议
为了保证设备的长期稳定运行,建议在日常使用中加强设备的维护保养,定期进行检查和维修,确保设备的安全可靠性。
同时,建议在设备使用过程中,严格按照使用说明书和标准要求操作,避免不必要的安全事故发生。
七、参考文献无。
安全型式试验报告
(GB4706.27-2003)
对于管道扇和隔墙扇,必须注意
N
气体从敞开的气道或其他明火设
备回流到室内(GB4706.27-2003)
7.12. 触点开距至少为 3mm 的全极断
N
2 开装置
CQC/TRFGB4706.27-2003
2007-12-19
报告编号:C-022-08CQC021J-S
GB4706.1-1998 GB4706.27-2003
7.8 除 Z 型连接以外:
— 专门连接中线的接线端子用
N
字母 N 标明
— 接地端子用符号 标明
N
— 标志不应设置在可拆卸的部
N
件上
— 应标出单极保护装置的对应
N
接线端子
7.9 可能引起危险的开关的标志或
P
放置
7.10 开关和控制器应用数字、字母或
P
其它方式表示
数字“0”只能表示“断开”档
N
位,除非不致引起与“断开”档位
[ ]附件齐全 [ ]其他
2.本记录中“P”表示该项检验方法/结果符合标准要求;
“F”表示该项检验不符合标准要求;
“N”表示该项要求[ √ ]不适用
[ ]或此次未进行检验。
本记录中以“[ ]”形式提供多个选项是,以在“[ ]”中划“√”表示该项被选中。
3.本检验[ ]有/[ √ ]没有偏离标准。
偏离的原因和偏离的情况:
样品照片
2007-12-19
报告编号:C-022-08CQC021J-S
第 9 页,共 40 页
FB-50 控制面板
CQC/TRFGB4706.27-2003
2007-12-19
报告编号:C-022-08CQC021J-S
型式实验报告
14 插拔实验 1、 分别在电压(100V—265V)下连续进行插拔 500 次后,电磁炉应能正常工作,无异常故障。
符合要求
15
电容冲击
1、分别在电压(100V—250V)工作状态下,用 15UF 的电容器以 4 次/S 的速度进行冲击试验,电磁炉能自动保护并能 瞬间进行恢复原来工作状态。
符合要求
16 乱码检查 1、电磁炉在任一正常工作状态下同时按多个或两个按键时无任何的异常现象。
将标准锅置于电磁炉加热中心,用 1%NaCL 水溶液注满,然后在一分钟内将预先量好的约等于标准锅容积 15%或 0.25Kg
24 防水实验 (两者取数量大的)的水均匀注入锅内,以引起溢出,1min 后将水擦干,然后立即进行电气强度和泄漏电流测试.且拆 机检查不应因水进入机内使爬电距离和电气间隙值减小到规定值。
13 高温运行
节直流稳压电源的输出电压,使散热片上的温度保持在 110—120 度之间,总试验时间为 4 小时以上,须保持锅内的 水温在 95℃以上,当锅内水量少于其容积的 50%时,应补充沸水至其容积的 70%以上;试验过程中电磁炉应能正常工
不适用
作;试验期间,在电源两端加 15UF 的电容性负载冲击,电磁炉能有效识别并进行保护,不能有烧机现象。
符合要求
合格
示“E1”报警;各功能键的功能检查结果正常,无失效或内容不符合。
最大输入功 1、 实际测量最大输入功率值应小于 10%标称额定功率值。
3
率测定 2、 实际测量最小输入功率值应大于 91%标称额定功率值。
符合要求(见附 表数据)
合格
APEX
常州市安普机电制造有限公司
CHANG ZHOU APEX ELECTRIC CO,;LTD
型式试验报告
报告编号:洗衣机型式试验报告
产品名称:
产品型号:
检验结论:
主检:
审核:
批准:
日期:
成都阿波电器有限公司
洗衣机型式试验报告
报告编号:共 8页第 2页
洗衣机型式试验报告
报告编号:共 8页第 3页
洗衣机型式试验报告
报告编号:共 8 页第 4页
洗衣机型式试验报告
报告编号:共 8 页第 5页
洗衣机型式试验报告
报告编号:共 8 页第 6 页
洗衣机型式试验报告
报告编号:共 8 页第7 页
洗衣机型式试验报告
报告编号:共 8 页第 8 页
本型式报告中的项目要求是按TCL内控标准,所检项目符合要求。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
合格
24
锅具对比
1、在标准条件下使用标准锅具测试的最大输入功率值应为:±10%P(额定功率);
2、在标准条件下使用其它锅具测试的最大输入功率值应为:±15%P(额定功率)。
符合要求
合格
25
煲汤功能
1、分别在250V、220V、180V电压下,以1杯绿豆10杯水进行试验,煮好的汤应味道鲜美,水分散失在最长煲汤时间内不大于30%,煲汤过程中,没有汤水明显溢出现象,过程中无任何异常现象程序结束后效果完好。
不适用
----------
36
噪音检测
1、在标准条件下,电磁炉的工作噪声标称范围测量值应为:A计权声功率级噪声值应≤50dBA。
不适用
----------
37
湿热实验
1、将电磁炉置于40±2℃,相对湿度90—95%的湿热试验箱内,电磁炉在断开电源情况下先在湿热箱内存放48小时,然后取出电磁炉在室温下放置24小时,并立即测试各项电气安全性能的符合性;验结束后电磁炉应能正常工作;电磁炉外壳不能有变形,陶瓷面板无脱胶现象,各按键操作灵活。
合格
3
锅具检知
1、分别在各电压(100V—265V)各个档工作状态下,将标准锅具反复移开应显示“E1”,放置锅具应进入工作状态
符合要求
合格
4
大小物检测
1、在各电压(100V—265V)及各个工作档下将≥Ф120mm的铁片放置在炉面上应能工作。
2、在各电压(100V—265V)及各个工作档下将≤Ф80mm的铁片放置在炉面上应不能启动且需显示“E1”。
《家用和类似用途电器安全:通用要求》
GB 《家用和类似用途电器安全:电磁灶特殊要求》
QB/T1236-1991《电磁灶》
EN60335-1-95《家产品设计及结构的安全通则》
CSC/T26-2004《电磁灶节能认证要求》
GB1019《家用电器包装通则》
GB 电工电子产品基本环境试验规程 试验A:低温试验方法
符合要求
合格
16
电压波动
1、在最大输入功率状态下,电压分别调至110-175V和252-280V之间电磁炉高低压保护性能符合;电压在175--252V之间连续上下调节,每分钟2—3个循环共100个循环后电磁炉应能正常工作。
符合要求
合格
17
功率转换
1、在器具的正常工作状态下,以连续3次/MIN的速度进行各种升降方式的调节功率转换键应无异常现象。
型式试验报告
(自主开发C20S05-A)
◆《备注(试验次数):□第1次□第2次◆第3次□第4次》 室温24℃
抄报部门
□生产部◆采购部◆技术开发部□工程部◆品管部□客户:□其它:
抄送人员
试验人员
审核
批准
供应商名称
接样日期
2008-06-25
测试日期
2008-06-25
抽样方式
新品
规格/型号
C20S05-A
不适用
----------
20
插拔实验
1、分别在电压(100V—265V)下连续进行插拔500次后,电磁炉应能正常工作,无异常故障。
符合要求
合格
21
电容冲击
1、分别在电压(100V—250V)工作状态下,用15UF的电容器以4次/S的速度进行冲击试验,电磁炉能自动保护并能瞬间进行恢复原来工作状态。
符合要求
不适用
-------
30
炒菜功能
1、分别在250V、220V、180V电压下,使用炒锅煮油、干烧烧烤盘或各类食物进行试验,电磁炉应能正常工作,使用过程不应出现故障或异常关机现象。
合要求
合格
31
防干烧试验
1、用标准锅内盛1公斤的食用油用火锅最大档加热,瓷板面的温度达300℃时显示屏显示E6,电磁炉关闭功率输出,然后在放置20分钟内不应出现有功率断续加热现象。空锅干烧要求在3分钟内有效保护。少水干烧要求在1分钟内有效保护。
不适用
----------
38
防水实验
将标准锅置于电磁炉加热中心,用1%NaCL水溶液注满,然后在一分钟内将预先量好的约等于标准锅容积15%或(两者取数量大的)的水均匀注入锅内,以引起溢出,1min后将水擦干,然后立即进行电气强度和泄漏电流测试.且拆机检查不应因水进入机内使爬电距离和电气间隙值减小到规定值。
电工电子产品基本环境试验规程 试验B:高温试验方法
电工电子产品基本环境试验规程 试验Ca:恒定湿热试验方法
电工电子产品基本环境试验规程 试验Ec:倾跌试验方法
GB2828 逐批检查计数抽样程序及抽样表(适用于连续批的检验)
GB2829周期检查计数抽样程序及抽样表(适用于生产过程稳定性的检查)
GB4212家用电器噪声功率级的测定
6)各种过热保护组件的失效故障试验;锅具传感器的热敏电阻移开后,电磁炉的功率连续档应在6分钟内停机保护(保温或全自动功能除外)。
1、以火锅最大档加热,调整电压在100V-110V时,电磁炉应关闭功率输出,且数码管显示“E4”
符合要求
合格
13
卸载检测
1、标准锅内盛入70%的水,接通电源并调整火力温度键至温度最高档位或最大功率档,将锅具以每分钟10次的速度抬离炉面10CM,重复1000次测试后无异常现象,且能正常工作。
符合要求
合格
6
定时功能
1、用火锅最大档进行加热,按定时键设定要求的最长时间,实测的预约时间应在设定时间的±15分钟内,且在工作过程中无任何和异常现象。
符合要求
合格
7
热效率
1、在标准要求条件下(锅具:26CM202材质复底汤锅)测量的热效率值应≥85%。
没有检测
-------
8
正常温升
1、在标准条件下电气组件的正常工作温升要求值应为:电容器(T-35℃)、IGBT<90℃;发热盘<150℃、电感线圈<70℃、微晶面板底面<200℃、电源变压器<70℃、互感器<70℃、
3、分别用汤锅/奶锅/炒锅/水壶:202材质(单、复底)、430材质(单底)、搪瓷锅、304材质(单、复底)等锅具检测,要求各项功能正常。
符合要求
合格
5
最大输入功率测定
1、实际测量最大输入功率值应小于10%标称额定功率值。
2、实际测量最小输入功率值应大于91%标称额定功率值。
符合要求(见附表数据)
合格
GB/电磁兼容试验和测量技术 电压暂降、短时中断和电压变化抗扰度试验
GB/T9254-1998 信息技术的无线电限值和测量方法
试验项目及试验结果
序号
检测项目
检测技术标准要求
检测结果描述
单项判定
1
安全性能
1、用六合一分别在(动态、静态、热态、冷态)下测试绝缘电阻/耐压测试/泄漏电流/接地电阻测试等无异常现象。
合格
22
乱码检查
1、电磁炉在任一正常工作状态下同时按多个或两个按键时无任何的异常现象。
符合要求
合格
23
电路故障
1、将线圈盘的一端开路,启动电磁炉工作应显示“E0”,蜂鸣器报警;
2、将传感器开路或短路,启动电磁炉工作应显示“E5”或“E6”,蜂鸣器报警;
3、将风机开路,启动电磁炉工作1分钟后应显示“E2”,蜂鸣器报警。
符合要求(见附表数据)
合格
10
两小时自动关机
1、当无锅具或锅具材料不正确时,应在1分钟内自动关机。
2、使用过程中,如不触摸任何控制键,应在2小时内自动关机。
符合要求
合格
11
过压保护
1、以火锅最大档加热,调整电压在265-285V时,电磁炉应关闭功率输出,且数码管显示“E3”。
符合要求
合格
12
欠压保护
不适用
----------
39
防潮实验
将整机可拆部件与主体一起放置预先配置好的潮湿箱内(相对湿度为93±2%,温度为20±5℃)经过48小时后取出重新组装,立即进行电气强度和泄漏电流测试并需符合电气安全标准要求.
不适用
----------
40
非正常试验
1)空载试验(有锅空载):测试空锅干烧或炉面过热保护功能(故障代码为E6)。
符合要求
合格
18
连续工作实验
1、在标准锅内注入其容积1公斤的植物油,用煎炒功能最大档(或最大输入功率)加热使油温升至200℃,然后不断的进行调节温度且使油温保持200℃±20℃,连续工作2小时,工作过程中无任何异常现象。
符合要求
合格
19
高温运行
1.在标准锅内加入其容积70%的水,将IGBT保护传感器拆除;接通电源,调整在最大输出功率值的电压下工作,并调节直流稳压电源的输出电压,使散热片上的温度保持在110—120度之间,总试验时间为4小时以上,须保持锅内的水温在95℃以上,当锅内水量少于其容积的50%时,应补充沸水至其容积的70%以上;试验过程中电磁炉应能正常工作;试验期间,在电源两端加15UF的电容性负载冲击,电磁炉能有效识别并进行保护,不能有烧机现象。
符合要求(见附表数据)
合格
9
异常温升
1、分别在180V、220V、250V的电压下,用标准配锅在火锅键最高挡位(最大输入功率)下加热工作直至温度保护显示“E2”后的各电气组件工作异常温升要求值应为:电容器(T-50℃)、IGBT(单/双):120±5℃/110±5℃;发热盘<180℃互感器<90℃、微晶面板底面<200℃、电源变压器<90℃、电感线圈<90℃、
2)风扇停转:主要测试IGBT的保护温度点设置或保护功能(故障代码为E2)。
3)空气入口或出口堵塞:主要测试IGBT的保护温度点设置或保护功能(故障代码为E2)。
4)热敏电阻开路或短路;测试控制电路自检功能或相应保护功能(故障代码为E5或E6)。