EFE-LF-550S操作说明书
CS-Instruments VA 550 VA 570 用户手册_中文说明书

中文使用说明VA 550 / VA 570流量传感器VA 550 VA 570 中文 V1.01页 1 of 31前言I. 前言亲爱的用户,非常感谢您决定选择VA 550 / VA 570. 请在安装和启动设备之前仔细阅读本安装和操作手册并按照我们的建议。
在仔细研究上述说明的情况下保证VA 550 / VA 570的无风险操作和正确的运作。
Sales Office South / Geschäftsstelle SüdZindelsteiner Str. 15D-78052 VS-TannheimTel.: +49 (0) 7705 978 99 0Fax: +49 (0) 7705 978 99 20Mail:***********************Web: Sales Office North / Geschäftsstelle NordAm Oxer 28cD-24955 HarrisleeTel.: +49 (0) 461 700 20 25Fax: +49 (0) 461 700 20 26Mail:***********************Web: VA 550 VA 570 英文V1.01 页 2 of 31目录表II.I. II. 1 2 3目录表前言 (2)目录表 (3)符号象征和标志 (5)信号根据ISO 3864 and ANSI Z 535 (5)安全注意事项 (6)3.1 3.2 设计用途 (7)安装调试 (7)4 技术参数 (8)4.14.1.14.1.2 电流型号 (9)Modbus (9)电流输出 (9)4.1.2.1 4.1.2.2 Aktive (9)Passive (9)4.1.34.1.4 4.2 4.3Pulse (9)Alarm (9)插入式流量计VA550 量程范围– (10)法兰版本VA570 量程范围 (11)5 尺寸 (12)5.1 5.1 5.2 5.3 VA 550 尺寸 (12)VA 570 尺寸 (13)螺纹版本VA 570 尺寸 (13)法兰版本VA 570 尺寸 (14)6 安装 (15)6.16.26.36.3.16.3.2 6.46.4.16.4.2 6.5 6.6 管/管要求 (15)进口 / 出口运行 (15)VA 550安装 (16)½“ 焊接接头带球阀 ½“ (16)定心钻带球阀 (16)传感器安装 (17)安装VA 550 进入到球阀上 (17)VA 570安装 (17)标准显示器(Housing) (18)紧固力矩 (18)VA 550 VA 570中文V1.01 页 3 of 31目录表7 连接图 (19)7.17.27.2.17.2.27.2.3 连接器引脚分配 (19)接线 (20)一般: (20)电源 (20)Modbus (termination): (20)8 VA 550 / VA 570操作 (21)8.18.1.1 8.28.38.3.18.3.2 主菜单(Home) (21)操作 (21)主菜单 (22)设置 (22)设置 (23)Modbus 设置 (24)8.3.2.1 8.3.2.2 Modbus 设置 (2001...2005).. (24)寄存器值(1001 ...1500 (25)8.3.3 8.3.4 8.3.5 8.3.6 8.3.7 脉冲/报警 (27)用户设置 (27)先进 (27)4 -20mA (27)VA 550 / VA 570 Info (28)9 10 补充文档 (29)更改历史记录 (30)VA 550 VA 570 中文 V1.01 页 4 of 31象形图/ 符号12 象形图和符号一般警告符号 (危险, 警告, 注意)一般注意事项 安装指导手册 (铭牌) 安装和说明书要考虑Signalwords 根据 ISO3864 和ANSI Z 535 危险r!警告!注意!留意!重要的!迫在眉睫的危险由于不正确的处理结果:严重的人身伤害或死亡可能的危险由于不正确的处理结果: 可能的严重伤害或死亡迫在眉睫的危险由于不正确的处理结果: 可能的人身伤害或损害可能的危险由于不正确的处理结果: 可能的人身伤害或损害其他注意事项, 信息, 提示由于不正确的处理结果: 操作和维护的缺点, 没有危险VA 550 VA 570 中文 V1.01页5 of 31安全注意事项3安全注意事项请检查本手册是否有对应的设备型号按照本手册中的所有说明。
可口可乐冰箱EMS-55控制器参数设置说明[5篇范例]
![可口可乐冰箱EMS-55控制器参数设置说明[5篇范例]](https://img.taocdn.com/s3/m/f8e4970630126edb6f1aff00bed5b9f3f80f7270.png)
可口可乐冰箱EMS-55控制器参数设置说明[5篇范例]第一篇:可口可乐冰箱EMS-55控制器参数设置说明可口可乐冰箱EMS-55控制器参数设置说明:一、怎么进人参数设定模式:1、关掉电源2、按住SET键3、打开电源4、持续按住SET键,直到显示PAS5、放开SET6、按3次SET7、按1次DOUWN(左数第二个键)8、按2次UP(左数第三个键)9、按4次DEFROST(左数第四个键)此时将显示第一个参数US(具体参数说明如下)参数代码USLSDIFCALRTDSLDSRCTCFSSPSDIPDDTTSP参数名称最高设定温度最低设定温度变量校对最短休眠时间待机延时待机启动时间制冷系统运行时间华氏或摄氏显示待机温度设定值待机变量待机温度设定值不间断降温功能启动温度防结霜功能温度设定值温度设定值初始值参数代码参数名称初始值02DE化霜间隔时间602DD化霜时间152.0DT化霜终止温度1000FOC蒸发器风扇循环启动时间0203FCF蒸发器风扇关闭时间0260FSP风扇温度设定值1530HT高温报警115240D2显示稳定性6472HI电压过高保护21500LO电压过低保护1404BO警报器开/关014BI警报器鸣叫时间6020AD警报延迟0200AF流量频率03FER食物柜模式累计运行记录(同时按住down 和up键持续3秒)HI最高记录温度CNTLO最低记录温度CCRV平均温度CHOC门打开次数RF人流计数压缩机循环次数压缩机营转小时人流密度设置二、怎么消除自学模式:1、关掉电源2、按住SET键3、打开电源4、持续按住SET键,直到显示室内温度数字5、放开SET完成三、怎么恢复出厂设置1、关掉电源2、同时按住SET键和DEFROST键3、打开电源4、持续按住SET键和DEFROST键,直到显示室内温度数字5、放开两个,完成。
第二篇:自助洗车机参数设置说明自助洗车机参数设置说明:在主板上按设置键进入U1 U01 刷卡累计总额(单位元)U02 投币累计总额(单位元)U03 软件版本 U04 软件更新日期P01 软件功能选择,0水机10洗车机,陆续会增加新的功能 P02 预扣金额,单位0.1元(设定为0.1元,启动实时扣费)P03 最大工作时间,单位分钟P04 多功能选项(请参考多功能详解)P05 打水灯延时时间,单位秒P06 设置第一路出水量或者工作时间(您假如此路是出泡沫或清水等等,就是设置泡沫、清水出水量等等,数值越大,出水量就越大,出水量就越多。
埃夫特工业机器人操作手册 ESR 系列工业机器人 JUMP Pallet 指令操作手册说明书

Zone
ZONE
圆滑过渡系数(默认值 z10)
输出参数
名称
类型
说明
res
INT
指令状态返回值
1 成功
第3页
埃夫特智能装备股份有限公司
注意:
图 1-1 Jump 运动示意图
1. Jump 运动的上升,水平,下降运动都是 PTP 运动。
2. 若 LimZ 设置的高度超过了机器人3轴最高位置,Jump 指令的 LimZ 参数则为机器人 3 轴最 高位置;若 LimZ 的设置高度低于当前位置或目标位置,Jump 指令的 LimZ 参数则为当前位置或目 标位置。
本手册仅作为对产品进行正常操作的指导,在产品使用过程中,埃夫 特公司并不对除产品缺陷外的其他原因引发的人身伤害、财产损失承担责 任。埃夫特公司郑重建议:参与机器人操作、示教、维护、维修、点检等 相关活动的人员,在学习完毕埃夫特公司准备的培训课程前,请勿赋予其 对机器人的操作使用权限。
版本号:V 1.0
第 2 章 Jump3/Jump3CP 指令................................................................................................ 6 2.1 指令说明......................................................................................................................6 2.2 指令格式......................................................................................................................6 2.3 参数说明......................................................................................................................6 2.4 使用示例......................................................................................................................7
JSF-550变频调速搅拌砂磨分散多用机使用说明书

JSF-550(变频调速)搅拌砂磨分散多用机使用说明书一.概述:JSF-550搅拌、砂磨、分散多用机是采用国外新技术的新产品,该产品集中了搅拌、砂磨、分散多种设备的功能于一体,是目前试验室人员最理想的试验设备。
二.主要技术参数1.电动机参数:550W220V 2.3A0.1HZ~300HZ2.变频器:0.75kw3.调速范围:无级调速0~10000r/min4.分散叶片直径:Φ50mmΦ60mm5.砂磨盘直径:Φ50mmΦ60mm6.升降行程:280mm7.外型尺寸:450mm×420mm×550mm(长×宽×高)8.重量:37kg三.结构1.本机采用三相异步电动机,通过变频无级调速,变频器显示屏直接显示转轴转速。
砂磨叶盘及分散叶片及转轴用罗纹直接连接。
2.筒体采用夹套式结构,可通冷却水,用不锈钢材料加工而成。
四.使用与维护1.使用时将选用的砂磨叶盘或分散、搅拌叶片顺时针与转轴拧紧。
2.松开锁紧手柄,调整转轴与容器的高低位置(可用定位圈的定位),然后拧紧锁紧手柄,夹紧容器,盖上容器盖。
3.接通电源,按“RUN”键,然后旋转变频器上的调速旋钮,调节速度至需要的转速。
关机时,可以直接关闭电源,也可以先将转速调整到零,再关闭电源。
变频器显示屏幕的四位数直接显示当前转轴的转速。
4.当电网电压低于198V时,会产生窜速现象(即转速突然升高),此时不宜使用本机。
5.关闭电源后至少等待10秒,才可开机,否则会产生窜速现象。
6.转速大于4000r/min时不宜开空机。
7.由于电动机带动负载,实际转速与空载转速有少许不符,若发现实际转速与空载转速严重不符(实际转速远远小于空载转速),则说明电动机此时处于过载状态,此时变频器会自动停止工作,机器停机。
8.本机保修一年,人为损坏不属于保修范围。
9.注意事项:面板上用户只要使用“RUN”“STOP”、调速旋钮,其他按键已由厂方设置参数用,请不要随意按动。
三肯ES ET EF系列变频器说明书

危险
如果忽视该提示警号而进行了错误的操作,可能会造成人身伤亡事故。
注意
如果忽视该提示警号而进行了错误的操作,可能会造成人员伤害或财产 损失。
※ 另外,即使是[注意]中所记载的事项,根据不同情况也可能造成严重后果。 因此所有内容均非常重要,务请严格遵守。
图形符号的意义
此图形符号表示可能会造成危险的事项。 在◇中标有具体的危险内容(左图所示情况为一般性危险)。
此图形符号表示必须引起注意的事项。 在△中标有具体的注意内容(左图所示情况为一般性注意事项)。
此图形符号表示禁止的事项(严禁)。 在 中标有具体的禁止内容(左图所示情况为一般性的禁止事项)。
此图形符号表示强制执行的项目(必须执行的事项)。 在●中标有具体的指示内容(左图所示情况为一般性的强制事项)。
1-1 安装注意事项 ............................................................... 5 1-2 布线注意事项 ............................................................... 6 1-3 运转操作时注意事项 ......................................................... 7 1-4 保养、检查注意事项 ......................................................... 8 1-5 关于废弃 ................................................................... 8 1-6 其它 ....................................................................... 8
servomexDF-550说明书

servomexDF-550说明书产品特点低持有成本高度稳定,每年只需一次量程标定。
无需定期更换程序化检测池。
一般保修5年。
高灵敏度一台仪器适用于多种背景气体测量200 pptzuidi检测限响应快速,失常工况恢复时间短应用电源110V ac or 220V ac 50/60 Hz 110V ac或220V ac 50/60 Hz 零点气体无要求量程气体在工作量程内的任何O2和N2混合气体规格气体类型:技术库仑电量法非消耗型电化学传感器性能工作量程:0-20ppb或0-10ppm*在两者之间的任意量程**最高可承受100 ppm波动持续15分钟,随后传感器自动关机以避免损坏最小推荐输出范围:0-20ppb基本误差(精度):+/-3%读数或+/-0.1ppb样气流量下的响应时间(T90):流速为0.7 L/min时小于15秒零点漂移/月:可忽略量程漂移/月:可忽略zuidi检测限(LDL):200ppt失常恢复时间:恢复到以前稳定读数±10ppb内不超过5分钟。
输出/输入输出:非隔离4-20mA dc、0-1、0-2、0-5或0-10V dc(可以设置模拟输出在标定时冻结)。
输出范围:0-20ppb或0-10ppm之间的任意范围。
报警电解液条件和温度。
双比例范围:两个自定义次要模拟输出范围,在超出主要范围后可重新比例调整输出。
气体比例因子:除N2或Ar以外的背景气体补偿。
用户标定组件自动控制:利用6V dc开关电源,软件控制外部量程/零点螺线管和阀门。
手动标定系统:在对焊组件内提供手动四分之一圈无弹簧隔膜阀和零点气净化器,紧凑集成在分析仪后面板以提高便携性高容量净化器:推荐气源纯度>10 ppb或样气源频繁切换时使用,如所有便携式应用。
容量比标准净化器高30倍。
N2壳体吹扫:H2等可燃性样气建议使用互锁吹扫外壳。
备用电池输入功率:允许不依赖交流电源的便携操作温度:0°C to 50°C(32°F to 122°F)0°C至50°C(32°F至122°F)露点:zuidi环境温度以下5°C(9°F)条件:无油、非腐蚀性、非凝气、不可燃尘埃:小于2μm微粒排空:Vent to atmosphere大气压样气流量:0.24 to 0.7l/min0.24至0.7l/min。
E+H 50系列电磁流量计简明操作手册
按 键进入菜单,仿真结束后SIMULATION CURR:OFF。 输入密码:0050,也可以直接输入“50” ,当从左向右数第三个“*”号变成回车键后按“E”确认就可。
仿真电流输出,仿真结束后改 OFF
仿真电流
该资料仅供参考,若有异议,请以随设备附带的操作手册为准
50系列电磁流量计脉冲设置
按键控制 同时按 按 键, 键 键并保持3秒以上直接回到主显示页位置,同时 键步步退出功能矩阵到主显示页位置,同时按 键取消数据输入。
口径mm 小流量切 除 (v ~ 0.04 m/s) 口径mm 小流量切 除 (v ~ 0.04 m/s) 口径mm 小流量切 除 (v ~ 0.04 m/s) 口径mm 50 2" 5 dm3/min 65 – 8 dm3/min 80 3" 12 dm3/min 100 4" 20 dm3/min 125 30 dm3/min 150 6" 2.5 m3/h 200 8" 5.0 m3/h 250 10" 7.5 m3/h 300 12" 10 m3/h
50系列电磁流量计的简明操作手册
目录 50系列电磁流量计启动显示和按键操作说明 2、 50系列电磁流量计快速设置 3、 50系列电磁流量计修改单位 4、 50系列电磁流量计量程范围设置 5、 50系列电磁流量计电流输出仿真 6、 50系列电磁流量计脉冲设置 7、 50系列电磁流量计脉冲输出仿真 8、 50系列电磁流量计小流量切除功能 9、 50系列电磁流量计空管检测功能 10、 50系列电磁流量计累积流量设置和复位
OFF – ON SPECIAL – OED – ON STANDARD OFF:(即没有激活EPD,也没有激活OED) ON SPECIAL(只用于DN<400): 用于分离型仪表(传感器和变送器分开安装),开启的空管检测功能 OED:开启开路电极检测(OED) ON STANDARD:开启空管检测功能,用于: ---一体化仪表(传感器和变送器组成一个机械单元) ---应用在测量管内衬和测量管电极,产生介质的覆盖层。 出厂设置:OFF 注意: 只有当传感器安装EPD电极,ON STANDARD 和ON SPECIAL才可选。 设备交货时,EPD/OED功能的缺省设置是OFF,这个功能根据需要必须激活。 设备在工厂标定是用水标定(大约500us/cm),如果流体的电导率与这个参考的电导率有偏差的话,就 需要在现场重新做空管/满管校正。(看EPD/OED ADJUSTMENT功能) 在你开启EPD/OED功能之前,调整系数必须是有效的。如果这些系数不是有效的,则显示EPD/OED ADJUSTMENT (6481)功能。 如果在调整中有问题,则在显示器上出现下列错误信息: ——ADJUSTMENT FULL = EMPTY: 空管和满管的校正值是相同的,在这种情况下,必须重新做空管校正/满管校正。 ——ADJUSTMENT NOT OK: 由于介质的电导率已经超过所需的范围,校正式不可以进行的。
pH ORP-5500系列pH ORP传输控制器操作手册说明书
pH/ORP-5500 SeriespH/ORP Transmitting Controller Instruction ManualNotes before Operation1.Notice before operation:(1) Carefully read the relevant parts of this manual before installation and operation to prevent wrong operation, measurement error and damage of instrument.(2) Improper installation and unsuitable flow speed will cause big measurement error, so please read the installation passage in detail.(3) This instrument is precise electrochemical measurement, and its installation and operation should be performed by technicians with relevant professional knowledge.(4) If for some special conditions, please consult our Technical Department for further details.2.Maintenance items:(1) The indicators’ quality guarantee is one year from the date of purchasing. During this period, if the meter has quality problems, manufacturer is responsible for maintenance work for free or changes it.(2) pH and ORP probes are consumer goods which without quality guarantee. Because, the lifespan is based on the medium and working conditions.(3) Manufacturer offers the maintenance service for whole life of the sold meters.(4) If the damage of the meter is caused by the following reasons, it is out of the maintenance service:A、The meter is burned or foundered caused by improper usage and maintenance.B、The meter is refitted or misused without permit.C、The meter is destroyed under the condition out of company’s regulation.D、The relevant damage caused by choosing the wrong type.E、The cable damage and rupture caused by improper installation and usage.F、The incorrect measurement of the probe caused by disconnecting or connecting wires personally.G、T he measurement inaccurate caused by privately cutting the probe cable.H、T he inner broken wire caused by indiscreetly disassembling.I、The consumptive materials are not within the scope the warranty.CATALOGⅠCONCEPTION (1)1.1 MAIN FEATURES (1)1.2 APPLICATION (1)1.3 NOTE: (1)1.4 TECHNICAL FEATURES (2)Ⅱ.INSTRUMENT DIMENSION AND TERMINAL DEFINITION (3)2.1. INSTRUMENT DIMENSION (3)2.2. INSTRUMENT REAR TERMINALS DEFINATION (4)Ⅲ. EQUIPMENT LAYOUT REFERENCE DIAGRAM (5)3.1 MILLIAMPERE TRANSMITTING CONNECTION LAYOUT (5)3.2 ELECTRICAL CONNECTION LAYOUT (5)Ⅳ.OPERATE SETTING (6)4.1 PANEL AND MAIN INTERFACE DISPLAY (6)4.2 KEY BOARD FUNCTION (7)4.3 SETTING INTERFACE (7)4.4 PROBE CALIBRATION (8)4.4.1 CALIBRATION (8)ⅤINTRUMENT MATING PROBE INSTALLATION GUIDE (9)5.1 PROBE OUTLINE DIMENSION (9)5.2PROBE INSTALLATION (10)5.3 PROBE INSTALLATION REQUEST (11)Ⅵ、MAINTAINING (12)6.1 PROBE MAINTAINING (12)6.2 PROBE USING ATTENTION (12)Ⅶ、INSTRUMENT AND PROBE FAULT COMMON TROUBLE SHOOTING (13)Ⅷ UNIT (13)Ⅸ、PURCHARSE INSTRUCTION (14)ⅠCONCEPTIONpH/ORP-5500 series pH/ORP Transmitting Controller is a popular type,high Cost performance instrument, mating pH/ORP probe,the entire instrument have high measurement accuracy,anti-interference,easy installation,simple operate features.1.1 Main Features1.LCD screen with prompt code, make every step operating get the presentation and guide;2.Programming pH&ORP function can be switched,suit any type of pH&ORP probe;3.Support six types of buffer calibration which can free combination,greatly broaden theapplication scope;4.Innovative manual input calibration method provide the biggest convinence for sitecalibration5.Selectable manual/automatic temperature compensation measurement type,providing thelargest flexibility.6.Independent external automatic temperature compensation probe provide high measurementaccuracy.7.Isolated/transferable /Reverse /instrument/Transmitter mode current output,compatible allthe transmitting receive modes.8.Double relay’s high/low limit and delay control satisfied pH or ORP region control anddosing;9.Mating split style、double combination probe easy change,one time wiring,permanent using(see the pH/ORP1220Aseries instruction);10.Industrial standard terminals,EMC electromagnetic compatibility measurement,platformdesign and development, series grouping;11.Satisfy world electric power supply standard,DC/AC power input nonpolarity connection,site operation will not worry about wrong connect;12.SMT Automatically Surface Mount Technology,AOI Automated Optical Inspection,ICT,FCT Full Computer Test,quality control means make, reliable quality;13.Every instrument make aging test,surface processing treatment,Full equipped electricalproductive technology,high quality level;14.Calibrate the probe one before leave factory;1.2 ApplicationThis instrument is used for pH/ORP online monitor in environmental protection of watertreatment, purified water treatment, industry process, aquaculture and etc1.3 Note:1.The instrument should place in dry environment or control box to avoid the sputtering orcondensation water causing leakage or measurement error2.This series instrument is platform develop result, various power supply can select, pls payattention to the voltage class when install the wiring;3.long time ultraviolet rays shining will burn the screen,result the gray scale reduce,so avoid installingdirect sunlight place.1.4 Technical featuresModel 5500 5510 5520 Power supply DC24V AC110 AC220V Supply frequency----------50/6050/60pH 0.00~ 14.00ORP -1000mV~ +1000mV Measurement rangeTemp. 0.0 ~99.9℃pH 0.01ORP 1mV ResolutionTemp 0.1℃ pH≤±0.05 ORP ≤±5 mV Indication error Temp≤ ±0.5℃Input impedance cause valueerrorpH ±0.03Approx equivalent input impedance 5×1012ΩPH buffer solution 10.0;9.18;7.00;6.86;4.00; 4.01Temp. compensation error pH ≤±0.05 Entire instrument error pH≤±0.1pH 0.05Entire instrument repeatability error ORP ±2mV Compensation range Temp. 0 ~ 50℃ Temp. 0 ~ 50℃Working environmentHumidity≤85% RH Cable length ≤20m (standard 10m )Control output double relay (single contact ON/OFF ),hysteresis can be set 3A(max), AC220V/AC110V 3A(max), DC24VContact capacity Power consumption<2.5WChannels One channelIsolated, transferable, adjustable, instrument/transmitter modeTechnical features(4~20)mA current loopLoop≤500Ω(max ),DC24VAccuracy ±0.1mAProtection grade levelIP65(with rear cover )Installation Panel mounted, fast installation clampDimension 96 mm×96mm×103 mm (H×W×D)hole dimension 91mm×91mmⅡ.INSTRUMENT DIMENSION AND TERMINAL DEFINITION2.1. Instrument dimensionShell front viewShell top view Shell side view2.2. Instrument rear terminals defination.Wire instruction:0V/220V AC 220V input terminal (pH/ORP-5520)0V/110V AC 110V input terminal (pH/ORP-5510)DC 24V input terminal (pH/ORP-5500) 24V A/B(Internal automatic recognition of polarity)EARTH Electromagnetic compatibility earth protection terminal Hi High limit alarm control terminal blocksLow Low limit alarm control terminal blocksT+ (T+、T-)external feed under transmitting modeT-/I+ public terminal under Transmitter /Instrument ModeI- (I+、I-) mA output terminal under Instrument mode INPUT Connect pH/ORP measurement electrode(Clear line)REF Connect pH/ORP reference electrode(shielding)CELL-T Connect temp. probe collect terminal(red line)GND Connect temp. probe earth terminal(black line)NC Empty terminalⅢ. EQUIPMENT LAYOUT REFERENCE DIAGRAM3.1 Milliampere transmitting connection layoutInstrument mode current loop wiring Transmitter mode current loop wiring 3.2 Electrical connection layoutRelay ON/OFF contact component control wiring diagram3.3 Control ModeaⅣ.OPERATE SETTING4.1 Panel and main interface display4.2 Key board functionKeyboardNameFunction1. pH automatic temperature compensation measurement mode ;2. Ph measurement status to check temperaturecompensation valueReturn3. Return or skip the revised item4. Parameter setting status circulate of thousand hundred ten one bit symbolSelect5. pH measurement mode long time press this key ,enter into pH manual mV calibration interface6. Processing 0~9 setting under parameters setting status.7. Long time press this key under pH measurement mode,enter into standard buffer solution calibration interface Add8. Check mV value under pH measurement status9. enter into function setting menu ; Enter10. confirm the modification item and save4.3 Setting interfaceUnder main measurement interface ,press“ ”key enter into parameter setting order NameFunction“pH” or “ORP” flashing ,select “Add” key, processing pH 、ORP function selection ,press “enter” to save ,enter intonext parameter setting 。
ST550-DTF技术手册V1.2
灵衡仪器Flex InstrumentST550-DTF技术手册Rev1.02014/11一概述ST550-DTF采用最新的Delta-Sigma AD转换技术, 具备双通道称重功能。
该仪表有两个独立串口:串口一为标准RS232,串口二是标准RS485。
1主要技术指标●显示器:128*64全点阵OLED显示屏●键盘:4个薄膜键盘●内分辨力:1000,000●最大显示分度数:300,0002主要功能●中文操作界面●基本称重功能:清零,去皮,清皮,毛重,自动零跟踪功能。
●高速数字滤波技术●2个串行口:RS232/RS485,支持Modbus-RTU二安装、外形尺寸三键盘菜单1键盘去皮键:用于去皮,在菜单设置返回上级菜单目录或者取消功能。
清除键:清楚皮重,在菜单设置选择上一个选项,编辑数字时翻转数字的功能。
清零键:仪表置零,在菜单设置选择下一个选项,编辑数字时移位数字的功能。
确定键:确认当前操作或者在主界面切换秤台操作。
2参数设定:同时按去皮和确定键,进入菜单设置,菜单目录如下:●秤标定⏹通道1AD值查看称重传感器AD的值分度值最小显示分度值设置标定重量标定时候加载的砝码值标定零点保持秤台稳定并且清空秤台,标定读取秤台零点值标定量程保持秤台并且并且加载响应砝码,标定读取秤台量程值⏹通道2(设置同通道1)●秤设置⏹通道1按键清零范围:0- 99%0禁止置零99%表示称重量程的99%范围以内开机可以作为置零。
开机清零范围:0-20%0禁止开机清零20%表示称重量程的20%范围以内开机可以作为零点。
自动零跟踪范围:0-99X0.1显示分度数0禁止零跟踪99表示在秤台在9.9个显示分度数仪表会自动零跟踪。
滤波等级:0-4从0到4,滤波等级越来越高,称重越稳定,反应响应也越滞后。
动态范围0-99显示分度数检查秤的动态范围⏹通道2设置同通道1⏹恢复出厂默认值●通讯设置⏹串口一波特率2400,4800,9600,19200,38400,57600通信参数7D 1S E : 7位数据位1位停止位偶校验7D 1S O : 7位数据位1位停止位奇校验8D 1S N : 8位数据位1位停止位无校验8D 2S N : 8位数据位2位停止位无校验8D 1S E : 8位数据位1位停止位偶校验8D 1S O : 8位数据位1位停止位奇校验通信方式无:无关联通信应用Modbus RTU: 该串口关联Modbus RTU功能从机地址仪表作为通信从机的地址:0-99⏹串口二设置同串口一●应用设置⏹系统语言英语,中文四Modbus协议MODBUS为主从形式的网络通讯协议,本仪表在MODBUS网络中作为从局而被上位系统调用。
SEL-551保护装置面板及定值修改说明
SEL-551保护装置面板及定值修改说明SEL-551保护装置说明79:重合闸 FAULT TYPE:故障相50P1T ACTION:速断动作 50P2T ACTION:过流动作TARGET:标志 RESET:复归 LAMP:指示灯 TEST:测试METER:测量表计CANCEL:取消EVENT:事件SELECT:选择STATUS:状态OTHER:其他的 SET:设置 CNTRL(CONTROL):控制 EXIT:出口(退出) MANUAL:手动 POSITION:位置 RETURN:返回 TRIP:保护跳闸二.SEL保护装置信号复归操作1.按TARGET RESET键复归面板指示灯。
2.按CNTRL(▼)键,面板显示MANUAL RESET Position:RETURN。
3.按EVENTS(SELECT)键,显示MANUAL RESET RESET? Yes No,光标停在No的下方。
4.按STATUS(◢)键,将光标移动到Yes的下方,面板显示MANUAL RESET RESET? Yes No。
5.按EVENTS(SELECT)键,先显示MANUAL RESET Position: RESET,1秒钟后再显示MANUAL RESET Position: RETURN,此时信号已复归。
6.再按EXIT键,面板又进入正常显示状态。
7.如果面板上没有显示电流,按一下METER(CANCEL)。
8.如果觉得以上步骤太麻烦,也可以将保护装置的工作电源断一下,过几秒钟之后,再送上。
三、前面板修改定值说明面板按键图示1.按SET(▲)键,屏幕出现SET/SHOW Relay Port Pass等字符,光标在Relay下方。
2.按EVENTS(SELECT)键,屏幕出现Relay Set Show,光标在Show下方。
3.按STATUS(◢)将光标移至Set下方。
4.按EVENTS(SELECT)键,屏幕出现PASSWORD:ABCDEF,光标在A下方。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
武汉逸飞激光设备有限公司 Wuhan YiFi Laser Equipment Co., Ltd. 东莞逸飞激光设备有限公司 Dongguan YiFi Laser Equipment Co., Ltd.
134.安装调试
在安装调试前,请仔细阅读安装操作说明,在没有对整机了解前,应联系本公司的工程师进行协调工作。 4.1.安装条件及要求
激光焊接对温度和供电电源有很高的要求。 温度 10~35℃ 湿度 ≤70%RH 大气压强 ≤86-106Kpa 环境清洁度 空气粉尘≤0.01g/m3 供电电源 380V AC 50Hz 电网波动 <5% 冷却水 去离子水或纯净的蒸馏水并保持洁净 4.2.调光
调光包括激光谐振腔、反射镜及耦合透镜架的调整,任何一部分的失调都会导致光纤出光能量的减少。 4.2.1.激光谐振腔安装调整
4.2.1.1.准备工作 1.先将晶体两端与棒套组件连接锁紧待用(注意调整好晶体与棒套组件的同心度及间距,具体装配方法见附注)。 2.准备好两支要安装的氙灯(或氪灯)。 3.安装调整前关闭电源,等各部分充分放电后,再进行操作。
4.2.1.2.工具 1.M3、M4、M5螺丝内六角扳手各一支。 2.曝光纸、白纸。
4.2.1.3.调整要求
激光光斑的调整是用红光来调整全反射镜片、部分反射镜片的平行度,以及与激光棒的垂直度,以达到光斑能量最大。 武汉逸飞激光设备有限公司 Wuhan YiFi Laser Equipment Co., Ltd. 东莞逸飞激光设备有限公司 Dongguan YiFi Laser Equipment Co., Ltd.
144.2.1.4.调整步骤
激光谐振腔结构示意图如下:
1.先用M5内六角扳手将上、下腔体连接锁紧螺丝④拆下,揭开上腔体放在一边待用。(如腔体内已通过冷却水,可先拧松放气螺丝⑨将余水放尽后再拆开腔体,可避免余水滴入腔体反射面。) 2.再用M3内六角扳手将棒套顶紧螺丝⑨拧松到一定距离,便于棒压盖⑦从下端头①孔中取出。 3.用M3、M4内六角扳手拧下下端头两端的棒压盖螺丝,取出棒压盖、棒套压块⑧、密封圈、垫片,将晶体棒套组件放入下腔体内,将棒套压块合在棒压盖上,再依次将垫片、密封圈、棒压盖套入晶体棒套组件放入下端头孔内,旋上棒压盖螺丝,调整好晶体棒套组件在下腔体中的位置,再拧紧棒压盖螺丝即可。 4.再用M3内六角扳手将棒套顶紧螺丝⑨拧紧,压紧棒套压块,也就同时压紧了棒套,但要注意拧紧力度,以免棒套变形。 5.将揭开的上腔体顶面朝下平放在工作台上,用M4内六角扳手拧下上端武汉逸飞激光设备有限公司 Wuhan YiFi Laser Equipment Co., Ltd. 东莞逸飞激光设备有限公司 Dongguan YiFi Laser Equipment Co., Ltd.
15头两端的灯压盖螺丝,拆下灯压盖和灯压盖密封圈(2个/边)。 6.将准备好的氙灯(氪灯)放入上端头的孔内,依次套入密封圈和灯压盖,旋上灯压盖螺丝,调整灯在上腔体中的相对位置,拧紧螺丝即可。 7.在晶体和灯安装完成后,将上腔体按扣合方向合上下腔体,拧紧上、下腔体锁紧螺丝,在灯两端装入灯极夹头锁紧,即可安装在激光器光具座上调整光路和通水。
4.2.1.5.注意事项 1.在整个腔体的安装过程中首先要注意轻拿轻放,不得有大的震动,以免损坏玻璃管或影响整个腔体的装配精度,并须带上指套装配。 2.在腔体安装或更换灯时,要注意保证整个腔体和配件的清洁,不得用手直接触摸反光瓦块镀金反射面。可准备一些干净的镜头纸和乙醇,随时清洁腔体和配件上的污物。 3.在装灯、装棒时不得遗漏垫片、密封圈等小部件,否则会引起漏水或其它不良后果。 4.在用顶紧螺丝顶紧棒套时,不得用力过大,以免损坏棒套。 5.在拧紧放气螺丝时,不得用力过大,以免螺纹拔丝,只要能封住不漏水即可。 6.上、下腔体扣合时不得装反方向,否则可能损坏腔体。可参照遮光定位条或对接水孔方位对位扣合。 4.2.2.全反、半反光路调整
4.2.2.1.准备工作 武汉逸飞激光设备有限公司 Wuhan YiFi Laser Equipment Co., Ltd. 东莞逸飞激光设备有限公司 Dongguan YiFi Laser Equipment Co., Ltd.
161.确认全反、半反镜片无损坏。
2.确认冷却系统运转良好。
4.2.2.2.工具
1.M3、M4、M5螺丝内六角扳手各一支 2.直角尺一把 3.曝光纸、白纸
4.2.2.3.调整要求
激光光路的调整是以红光光路为基准,主要调整全反射镜片、部分反射镜片的角度,使得光斑能量最大,并且激光光路与红光光路同轴。
4.2.2.4.调整步骤 1.装配好激光器聚光腔后,先取下半反膜片及全反膜片。 2.将小孔光栏分别套上晶体棒套两端,通过调整指示光源镜架的四个调整螺钉,将半导体激光调到与YAG晶体轴线同轴,即半导体激光同时透过晶体棒套两端的小孔光栏,并在白纸上呈现一个圆形的红色光斑,(经反射后与小孔重合为止)。将另一小光栏装入45°半反镜座小孔上,检查经过晶体的两端小孔光栏的半导体点是否穿过反射镜小孔中心,即三个小孔是否成一条直线,若有所偏移,则分别调整45°半反镜座或聚光腔,直到三个小孔准直成一条直线。 3.将半反膜片装上,锁紧后,通过调整全反、半反镜架的两个调整螺钉,将半导体反射点调入晶体棒套一端的小孔光栏内。 4.将全反膜片装上,锁紧后,通过调整全反镜架的两个调整螺钉,将半导体反射点调入晶体棒套另一端的小孔光栏内。 5.取下三个小孔光栏。打开主电源,将激光输出能量调到较低值武汉逸飞激光设备有限公司 Wuhan YiFi Laser Equipment Co., Ltd. 东莞逸飞激光设备有限公司 Dongguan YiFi Laser Equipment Co., Ltd.
17(120A,1.0ms,1Hz),微调全反膜片架,利用上转换片和爆光纸进行观察,使激光光斑成规则的圆形。若光斑左右存在缺隙,则调整全反膜片和半反膜片架左右端调节螺钉。若上下存在缺隙,则调整全反膜片和半反膜片架上的上端调节螺钉,直到光斑较圆,且激光能量分布均匀,激光与半导体同轴。此时,激光输出效果最好。
4.2.2.5.注意事项
1.调整膜片架时一次调整幅度不宜过大。 2.应在工作电压较低时进行调整。调整激光输出时,切勿将手碰着氙灯两端的电极。 武汉逸飞激光设备有限公司 Wuhan YiFi Laser Equipment Co., Ltd. 东莞逸飞激光设备有限公司 Dongguan YiFi Laser Equipment Co., Ltd.
185.操作使用
5.1.操作面板 本机具有2个操作面板。 操作面板如图所示: 1.电源面板
2.工作台操作面 武汉逸飞激光设备有限公司 Wuhan YiFi Laser Equipment Co., Ltd. 东莞逸飞激光设备有限公司 Dongguan YiFi Laser Equipment Co., Ltd.
195.2.电源操作
5.2.1.开机操作 1.接通外循环水,合上冷却系统空气开关。 2.接通三相交流电源,合上主机空气开关。 3.释放急停,然后旋开钥匙开关键,此时电源面板显示灯亮,其上显示“P”。 4.按压选项键,大屏幕显示“ON”,再按压确认键,电源开始自动执行充电、预燃等程序,约1-2分钟,预燃显示灯亮,表示氙灯被点燃。 5.按压装载键,电流、脉宽、频率屏幕上显示数值,如屏幕上是自己所须数值,则按压确认键,大屏幕按压L后的· 被显亮,激光指示灯亮,此时由激光器侧开关控制,可以出激光了。 6.如不是所需数值,可按压编程键,设定自己所需的电流、脉宽、频率数值。 a 按压编程键,再按压确认键,电流指示灯亮,这时可以放置自己所需要的电流值。 b 按压选项键,脉宽指示灯亮,可设置脉宽。 c 按压确认键,频率指示灯亮,可设置频率。 d 如仍有更改必要,按压选项键,可任意更改电流、脉宽、频率值。 e 本机电流、脉宽、频率三者的乘积程序中已有限定,不致出现误操作。 7.编程完毕,按压确认键,大屏幕指示灯亮。 8.按压确认键,直至L后的·被显亮,可以出激光了。 9.另外机中贮存器内可装载100组固定数据组用户可将自己试验好的各种材料的激光工艺参数,按数字顺序编制数据组,开机、装载后根据所焊接的材料特性,选择合适的数据组,例如按压“5”键,则程序会自动调取第五组数据进行激光焊接。 10.本电源还可以对电源波形编程,用户可根据需要编制最多15段电源参数,操作程序如下: a 按压编程键,再按压确认键电流指示灯亮,此时显示电流和脉宽为常规状态下工作电流和脉宽,同时也是15段电源参数的第一段。 b 再按压编程键,此时进入第二段电源参数,按步骤6设定需要的参数,设定好后,再按压编程键,可进入第三段电源参数编辑,以此类推,可根据需要设置最多15组电源参数。 c 按压确认键,频率指示灯亮,可设置频率,再次按压确认键,直至频率L后的·点被点亮,电源已作好准备,可以出激光了 11.分别按压时间、次数键,可显示整机工作时间或激光放电次数。