伊顿低温型液压站使用说明书

合集下载

Eaton 控制站说明书

Eaton 控制站说明书

4C4Non-metallicCl. I, Div. 2, Groups A, B, C, DCl. I, Zones 1 & 2, (A) Ex de IIB + H 2 T6Cl. II, Div. 1, Groups E, F, G (cUL)PTB ATEX Certified 3117Ex de IIC, T6, Zones 1, 2, 21, 22Applications:Control stations are used as a remote means of:• Motor control• Visual indication of equipment performance• On-off control of circuits • Circuit selectionCommon applications include:• Areas which are hazardous due to the presence of flammable vapors, gases or highly combustible dusts• For installation at petroleum refineries, chemical and petrochemical plants and other process industry facilities where similar hazards existCertifications and compliances:• UL/cUL Listed• Class I, Division 2, Groups A, B, C, D • Class I, Zones 1 & 2, Ex de IIB + H 2, T6• Class II, Division 1, Groups E, F, G (cUL)• AEx de IIB + H 2, T6• Type 3, 4, 4X; IP66• CENELEC-PTB 00 ATEX 3117• Ex de IIC, T6, Zones 1 & 2, IP66Features:• NEMA 4X, IP66 enclosure with formed-in-place gasket• Available with all operators: indicator lights, potentiometers, control switches, pushbuttons, terminal blocks and meters • Base mounted contact blocks• Easy change-out components snap in place on DIN rail• Enclosure meets UL94-VO; also available in anti-static Ex-e materials • Inserts for mounting DIN rails• Available with a maximum of two entries – top and bottom for conduit fittings or cable glands• Suitable for universal mounting plates on pipes, conduit, wall or channels• Mounting dimensions data molded on back• Captive, corrosion-resistant cover screws • Built-in mounting slots for wall installationGHG43 control stationsUL/cUL ListedNEMA 4X, IP 664CNon-metallicHow to build a GHG43 catalog numberGHG43 control stationsAUnoccupied spaces must be filled in with KLM for correct positioning of devices.GHG43 2 – Size 2 enclosureCodes see page 152Pushbutton DRTCodes see page 152Mounting area ADouble pushbuttonGHG43 4 – Size 4 enclosureCodes see page 152Key operated pushbuttonCodes see page 153Mushroom head pushbuttonCodes see page 153Mounting area ASignal lamp4C4Non-metallicHow to build a GHG43 catalog numberGHG43 controlstationsCodes see page 154PotentiometerCodes see page 155Requires 2 spacesMeasuring instrumentCodes see page 156SwitchCodes see page 156Requires 2 spacesControl switch Ex 23 10ACodes see page 154Terminals and coverblanking plugCable entriesNPTMetric No entriesNo entriesTwo entries2 x 1/2” Myers hub,STGK1 zinc gland plate2 x M25 plastic cable gland M25blanking plug2 x 3/4” Myers hub,STGK2 zinc gland plate (stainless steel control stations only)2 x M20 threaded entries Gland plateOne entry2 x 1/2” Myers hub,SSTGK1 stainless steel gland plate 2 x M25Threaded entriesGland plate2 x 3/4” Myers hub,SSTGK2 stainless steel gland plate(stainless steel control stations only)1 x M32 plasticcable gland 1 x 3/4” Myers hub,STGK2 Zone 1gland plate1 x M25Threaded entry,blanking plug andgland plate 1 x 1/2” Myers hub,STGK1 Zone 1gland plate2 x M25Threaded entry,1 blanking plug andgland plate 1 x 1/2” Myers hub,SSTGK1 stainless steel gland plate1 x M20Threaded entry,blanking plug andgland plate 1 x 3/4” Myers hub,SSTGK2 stainless steel gland plate1 x 3/4”Myers hub,SSTGK2 stainless steel gland plate4CNon-metallicPushbuttons technical dataGHG43 control stationsPushbuttons:• Used for logic controls in hazardous areas • Single or double units • Used with all operators • Base mountingPushbuttonType of protectionEx de IIC T6Mechanical and electrical life >105 operationsSee page 157 for explanation of contact symbols.Pushbutton DRTDR TOCodeA B CDContact system Code B434445Contact system Code B232425Contact system Code B131415Key operated pushbutton SLTSL TOCodeA B CDouble pushbutton DDTODD TOCodeA B C D EB 01 - Includes the following discs: Start, stop, I, O, andred, green, yellow, white and black blank discs.C For marking guide for pushbuttons, see page 158.Inscription ALL BIIIStopStartSpecial text on order CCode C01020304060799Lockout see page 158Code D(leave blank if no lockout required)Inscription ALL BIIIStopStartSpecial text on order CCode C, D left/right01020304060799Lockout see page 158Code E(leave blank if no lockout required)PushbuttonKeyLockableYes Yes Yes No No Yes Code C1234564C4Non-metallicPushbuttons and signal lamps technical dataGHG43 controlstationsMushroom head pushbutton SGTSG TCodeAB CDE FContact system Code B535455Color of pushbutton RedY ellowBlack actuatorCode C 123Function Spring returnMaintainedKey releaseCode D 123Inscription StopStartEmergency stopCode E060711Lockout see page 158Code F(leave blank if no lockout required)Signal lamp:• Used for positive feedback indication • High intensity with special reflector and optical lens• Accomodates most input voltages • Base mountingLampType of protectionEx de IIC T6ColorsRed, green, yellow, clear and blueSignal lamp SILSI LCodeABCColored lens cover White Y ellow Red 1 pkg. white, yellow, red, greenGreen BlueCode B 123456Voltage 20-250 VAC / DC10-33 VAC / DCCode C01314CNon-metallicTerminal blocks and potentiometers technical dataGHG43 control stationsTerminal blocks:• Terminal block for easy field connections • Base mountingTerminal blocksType of protectionEx e IIConductor size 4mm / 12 AWG6 terminals 2 x 4mm Undrilled cover (no terminals)Code B6100Terminals and cover plugs KLMKL MCodeABPotentiometers:• Used to adjust resistance to vary motor speed or light levels • Scale 0 to 100%• Base mountingPotentiometersType of protectionEx de IIC T6Connection terminals2 x 2.5mm / 14 AWGPotentiometer POTPower consumption 1WResistance Ω1,0002,2004,70010,000PO T CodeAB4C4CNon-metallicAmmeters technical dataGHG43 control stationsAmmeters:• Used to measure motor current draw for efficiencies and maintenance• Slide in scales to accommodate any amperage range• Red indicator for quick visual indication to compare set points and actual valuesAmmetersType of protectionEx e II T6Rated current marking Red indicatorMovement Directn/1 A 0-2 mA 4-20 mACode B1236Ammeter measuring instrument AM 72DDRequires two spaces.M72CodeABMovements 0-20 mA and 4-20 mA are only available with 0-100/120% scale.Direct measurement Interchangeable scale for C. T . n/1A Code CScaleCode CScaleCode CScaleCode CScale020 - 1/1.5A 020 - 1/1.5A 090 - 30/45A 160 - 200/300A 150 - 150/225A 220 - 100/150A4CNon-metallicRotary switches technical dataGHG43 control stationsRotary control switches:• Used for selectable operations (i.e. Hand-Off-Auto)• Two independent contacts• Available in any contact configuration • Spring return or maintained position • Available with lockout positionsSCT Ex 23Type of protectionEx de IIC T6Ex de IIC T6Switching capacityAC II: 20V/6A 400V/4A DC II: 24V/6A 60V/0.8A 110V/0.5A 220V/0.2AAC II: 230V/6A 500V/6A DC II: 24V/6A 48V/4A 60V/0.8A 110V/0.5A 220V/0.4ARotary control switch SCTCode B Code CInscriptionCode CInscription010I07I 0II 29OFF ON 99Special – text to be given on orderSwitch mechanismSC TCodeABC DRotary control switch Ex 23ECode BInscription010I 99Special – text to be given on orderE Requires two spaces in cover.Ex 23 Code ABCDEContact system Code D123456Same as SCT above except up to 4independent contacts4C4Non-metallicRotary switches technical dataGHG43 control stationsSwitched mechanismCode DPadlocking facilityCode EContact configurationsNormally closedNormally openNormally closed extended over two positionsNormally open early make/late breakChange-over break before makeChange-over make before breakExample of switch type 10This example is the switch type 10 Stop-Run-Stop. The switch has 3 positions – the normal position is center and can be switched left or right. An arrow (®¬) indicates spring return. (See codes for switch mechanism). Contacts 1-2 only close in the Stop position. Contacts 3-4 close only in the Start position. Contacts 5-6 are normally closed and remain closed when switched to the Start position and open when switched to the Stop position.Code C Contact systemType 00Two-position01Two-position 02Two-position03Single-pole changeover05HOA07Three-position single levelCode C Contact System Type09Three-position10Three-position12Three-position13Two-position14 2 Two-position15Three-position double-pole changeover4CNon-metallicLockouts for pushbuttonsand marking guide for pushbuttonsGHG43 control stationsLockouts for DRTO pushbuttons:XCode DShroud cover for pushbuttonY-lockout with bolt and chain ZCode DPadlocking fire alarm cover for pushbuttonLockouts for DDTO double pushbuttons:XCode EDPadlocking cover fordouble pushbutton without holeZCode EPadlocking cover fordouble pushbutton with holeLockouts for SGT mushroom head pushbuttons:XCode FPadlocking cover foremergency stop pushbuttonNot permitted in IEC locationsZCode FPadlocking cover foremergency stop pushbutton with bolt and chainMarking guide for pushbuttons:Special textMarking requiredStandard abbreviationActual marking on discAcknowledge AK ACK Up UP UP US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2023 Eaton 1594C4Non-metallic GHG43 control stationsDimensions:GHG43 Size 2GHG43 Size 4End view of back box。

伊顿Eaton DX系列UPS使用手册说明书

伊顿Eaton DX系列UPS使用手册说明书
Eaton DX 系列使用手冊
6K/10K CN(XL)/10K CNXL3:1 USER MANUAL
感谢您使用伊顿产品! 请严格遵守本手册和机器上的所有警告及操作说明,并妥善保管本手 册。在没有阅读完所有的安全说明和操作说明以前,请不要操作本 机。意事项”,以确保正确和安全的使用。并请
下表中L对三相机而言,表示L1、L2、L3且三相线径相同。
型号 G
输入 N L +
电池 G L
输出 N G
DX 6K CN 6mm2 6mm2 6mm2 6mm2 6mm2 6mm2 6mm2 6mm2 6mm2
DX 6K CNXL DX 10K CN
6mm2
10mm2
6mm2
10mm2
6mm2
10mm2
电气安全 非专业人员请勿打开机壳,请有授权的维修人员操作。 1. 上电前,请确认已正确接地,并检查接线和电池极性的连接正确。 2. 当UPS需要移动或重新接线时,应断开UPS 所有电气连接,保证UPS完全停机,否
则输出端仍可能带电,有触电的危险。 3. 请使用伊顿指定的附加装置和附件。 4. 小心电击:
1、简介
本系列UPS 是一种先进的在线式正弦波不间断供电系统,可以为您的精密设备提供可 靠、优质的交流电源。其适用范围很广,可以用在电脑设备、通信系统以及工业自动 控制设备上,同时还可提供丰富的选配件功能,满足不同需求。它的双转换在线式设 计,不同于后备式UPS。当市电正常时,它会对市电进行调整、滤波,为您的设备提 供更加优质的电源;当市电异常或中断时,它会无时间中断地从备用电池为您的设备 提供优质的后备电源;在过载或逆变失败情况下,UPS 会转换到旁路状态,由市电供 电;若过载情况消除,UPS 会自动转回到逆变器供电状态。 本手册适用于EATON DX系列产品,包括:

伊顿DV1X1系列低压变频器说明书

伊顿DV1X1系列低压变频器说明书

PowerXL DV1X1系列低压变频器简单 可靠 高效新一代紧凑型变频器适用于0.2kW至22kW的三相异步及同步电机2PowerXL DV1X1系列低压变频器目录PowerXL DV1X1系列低压变频器产品概述技术特点产品标准产品型号技术参数端子接线图配线及端子规格外观尺寸可选附件制动电阻选型 (222345781011)伊顿DV1X1系列变频器是针对机械设备制造领域所开发的全新一代紧凑型变频器,产品采用书本式窄体设计,具有体积小,温升低,操作便捷,稳定可靠以及经济高效的特点。

DV1X1系列变频器全部采用强化防护涂层电路板和先进的结构设计,兼顾了产品的散热和防尘需求,保证了产品可靠性和稳定性,广泛适用于各种恶劣的现场环境。

PowerXL DV1X1系列低压变频器产品概述●支持V/F 控制(自定义曲线,节能控制等),开环矢量控制,满足不同应用控制需求●支持同步电机控制,更高能效,减少碳排放●强化PCBA 防护涂层,符合3C3,3S3等级要求,可耐受严苛的环境条件●全系列内置制动单元,更强的动态制动能力●内置双Modbus RJ45接口,组网更便捷●支持并排零间距安装,节省柜内空间●输入输出信号:● 数字量输入:4路 DI1- DI4, 支持PNP 或NPN●模拟量输入:1路 AI (可设置为DI 使用)●数字量输出:1路 DO ,集电极开路输出●继电器输出:1路 RO ,带有公共点的1常开和1常闭触点●模拟量输出:1路 AO●丰富的软件应用功能:● 内置节能控制算法,有效降低能耗,并可监控用电量数据● 多段速功能● 瞬时掉电控制功能● 自动/捕捉再起动功能● PID 控制器● 内置张力控制算法● 摆频(三角波)功能●用户自定义程序运行模式● 通过功能强大的Drive Xpert 软件,用户可以应用虚拟示波器功能在电脑上实时监控各项参数,使调试,监控,故障排查更为便捷高效技术特点DV1X1系列低压变频器 /electrical目录描述 页码 DV1X1系列低压变频器3DV1X1系列低压变频器产品型号DV1X1系列低压变频器 /electrical 产品型号说明注:* 功率是基于220V/380V 四级或六级鼠笼式感应电机确定,仅供参考。

亚太地区Eaton水力系统产品说明书

亚太地区Eaton水力系统产品说明书

Eaton Construction & Mining© 2010 Eaton Corporation All Rights Reserved Printed in USADocument No. E-HYOV-MR006-E November 2010EatonHydraulics Group Asia Pacific Eaton Building4th Floor, No.3 Lane280 Linhong Rd. Changning District Shanghai 200335ChinaTel: (+86 21) 5200 0099Fax: (+86 21) 5200 0400EatonHydraulics Group USA 14615 Lone Oak Road Eden Prairie, MN 55344USATel: 952-937-9800Fax: 952-294-7722/hydraulicsEatonHydraulics Group Europe Route de la Longeraie 71110 Morges SwitzerlandTel: +41 (0) 21 811 4600Fax: +41 (0) 21 811 4601& superior control to finish the job fasterA AB BC CD DE EF FG G HH I JElectronic Controls Electronic Joystick Open Circuit PumpClosed Circuit Propulsion Pump Fluid Conveyance Traction Motor Control Valve FiltrationClosed Circuit Propulsion Pump Propulsion MotorElectronic Controls & Joystick Conveyor Motor Auger Motor Open Circuit Pump Control Valve Fan Drive Fluid Conveyance FiltrationEaton is in the details.Whether it’s digging or using one of its manyattachments, when Eaton is on the inside skid-steer loaders are more productive. Eaton provides robust solutions from compact motors to complete electro-hydraulic propulsion systems that ultimately help users get more work done.Asphalt pavers can count on Eaton for reliable handling and precise shaping when building the roads wedrive on everyday. Eaton provides complete hydraulic solutions that manage heavier loads, endure the harsh environment, and deliver the precise control… mile after mile.Skid-Steer LoaderAsphalt PaverB DCFEGHACEBDJHF I AGPlatform Spotlight: an example where we excelProblem SolverChallengeA paving equipment manufacturer decided to expand its line of medium-sized asphalt pavers. T he re-design translated into a more compact hydraulic system.SolutionEaton partnered with a key distributor to design and provide a compact circuit of hydraulic productsincluding pumps, motors, filters, and custom valve/manifold assemblies.Why EatonEaton provided a package that fit thespace requirements and performanceneeds to help manufacturer outpacethe competition.。

EATON Magnum 说明书 IEC 低压万能式断路器 产品说明书

EATON Magnum 说明书 IEC 低压万能式断路器 产品说明书
伊顿电气有限公司 苏州工业园区苏虹西路193号 苏州工业园区苏虹中路306号 Tel: 0512-67163728 62585099 Fax: 0512-67169535 62585076 Postcode: 215021
ESE-LV-ACB-OM-0804
MW1双宽度型万能式断路器使用双宽抽屉座以适应最大 额定值为6300A的需要。水平一次插入式触头和接线端子 作为标准件。可选的垂直端子适配件可供垂直平面的母线 端子优选。以及在独立外壳结构中使用。
MWN 窄型抽屉座 正视图 (带断路器)
MW1 标 准 型 抽 屉 座
4
正视图
后视图 后视图
概述
Magnum 低压万能式断路器为用户提供满足现代配电系统日益增高的综合需要。产品经设计和实验,适用于 额定电压为220/415, 440, 和 500/690AC. 的低压配电设备中。Magnum 断路器适用于抽屉式和固定式安装方式 。三种不同的框架尺寸均具有高额定短路分断能力,无熔断器可至100kA ,其额定电流从800A到6300A。
Magnum 低压断路器的新潮流
伊顿低压断路器影响工业标准已达30多年。始终把可靠性和为顾客服务放在首位,伊顿电气明确地采用IEC标准。 伊顿的新一代万能式断路器体积更小,性能更高,应用范围更广。 Magnum 低压断路器的设计,充分考虑配电设备用户和低压柜厂家的需求,达到最大的使用灵活性。为了取 得最大的安全性,采用了现代化的透门式设计,不用开门就可以直接操作断路器的储能手柄、脱扣单元、控制 单元和关门指示灯。 断路器的高耐压和高分断额定值提供了最大的选择性和系统的配合性,以应对当今电力配电系统的高故障电流。 紧凑、模数化的断路器框架等级使紧凑、经济的结构和通用的外壳成为现实。 电流互感器、额定值插头、脱扣单元和附件,都可以在现场安装更换,不用作整机备用库存。

伊顿液压拖拉机应用手册说明书

伊顿液压拖拉机应用手册说明书

伊顿液压拖拉机应用手册伊顿流体动力( 上海) 有限公司,总部位于外高桥保税区内,在外高桥及康桥工业区设有工厂,在全国设有20 个销售办事处。

公司致力于液压系统与零部件的设计、组装生产及测试和销售服务,以世界级的产品质量和服务扩大中国市场。

公司现已经建立了完善的仓储物流一生产制造一技术支持一客户服务体系,为客户提供完备的供货、定制生产、技术选型、培训、售后服务和外币结算服务。

另外,公司作为伊顿大中华区乃至亚太区的服务及维修中心,为客户提供完善的售后服务。

成立于1994 年,2002 年完成独资,现位于济宁市开发区伊顿工业园区(伊顿在中国建立的第一个工业园),主要生产液压马达、液压转向器、液压阀、柱塞泵、扭矩发生器。

公司拥有KAPP 、BLOHM 等世界一流水平的磨床、先进的CNC 加工中心、可靠和高精度检验试验设备,于1997年通过ISO9001质量体系认证,是伊顿公司核心产品和零部件的生产基地,为世界知名厂商提供高质量的产品和服务,满足伊顿全球客户的需求。

伊顿液压(泸州)有限公司是伊顿全资拥有的外商独资企业。

公司位于四川泸州经济技术开发区,是国内优秀的液压管路整体方案的提供者之一。

公司产品主要涵盖:液压胶管接头、过渡接头、胶管总成、钢管总成及不锈钢液压管路连接件。

公司拥有大批国内外先进的MAZAK 、Kitako 等先进数控车床、拥有先进的无氰镀锌生产线,镀锌质量达到国内外先进水平,拥有进口FINNPOWER 扣压机和试压设备组成总成装配生产、检测线。

并通过了ISO9000,ISO14000等国际体系认证,产品销往北美,澳大利亚,新加坡等海外客户以及国内工程机械,海洋钻井平台,风电,冶金等行业。

2005 年4 月,伊顿(中国)投资有限公司整体收购了宁波永华液压器材有限公司,成立了伊顿液压(宁波)有限公司,公司位于宁波市高新技术产业开发区。

公司有一大批先进的CNC 自动送料和加工的机床、接头装配的自动加工流水线、进口FINNPOWER 软管总成扣压设备和进口TRANSFLUID 硬管弯管设备。

伊顿 EACB-101B 技术手册 - TMY0024.B - EN 说明书

伊顿 EACB-101B 技术手册 - TMY0024.B - EN 说明书

EACF-101B Series Explosion-proof Fixed Camera StationEx Marking:Ex db I MbEx db [ib] I MbEx db IIC T6 GbEx tb IIIC T80℃ DbCertificate numbers: IECEx ExTC 21.0013XBIS: R-41268585Copyright StatementCooper Yuhua (Changzhou) Electric Equipment Manufacturing Co., Ltd (hereinafter referenced as Cooper Yuhua). Claims copyright ownership of the contents (including text and images) of this Instruction Manual. Any content may not be copied, transferred, modified or reproduced by any person or organization without expressed permission of Cooper Yuhua.Cooper Yuhua remains the right to modify the content and technical specifications of the product in this Instruction Manual without any form of notification, in order to provide the newest and most advanced product. The end users can get the latest product information on Yuhua’s website:/yuhua-cctv Trademark statementThis is the trademark of Cooper Yuhua (Changzhou) Electric Equipment Manufacturing Co., Ltd., all right reversed. The other trademark and trademark right appeared in this Instruction Manual belongs to its legal holder.2EATON Quality GuaranteeFor EACF-101B explosion-proof fixed camera set, we provide free maintain service in the guarantee period, but we will ask the user to pay for the cost of labor and component in the follow conditions:• Damage caused by improper installation or operation and not in accordance with this instruction manual.• Damage caused by unauthorized disassembly.• Thunder or other force majeure natural disasters.If any other contracts between clients and us exist, we will follow the promise or regulation strictly.Security AssuranceOperation of this product fulfills the following two requirements:• No adverse interference in operation;• The operation of this product cannot be interfered by external factors even adverse interference.3EATON 4Installation instructions for EACF -101B CCTV camera stationEnglishEATON TMY0024 August 2024 Notice•The user shall not disassemble this product optionally, such as remove the top cover or bolts may cause leakage of water or electricity. Please operate the product according to the requirements in this Instruction Manual;•Ensure this product is always used in environment with atmosphere pressure, ambient temperature and relative humidity specified in Chapter 1.6;•To be sure the power supply complies with the requirement indicated in the nameplate;• The internal and external grounding shall be reliable;•Ensure the installation is firm and reliable, to avoid unexpected damage of the camera;•Protect the flame-proof joints from stumble and crack in installation, operation and maintenance.Thank you for selecting Cooper Yuhua product!Please read this Instruction Manual carefully beforeInstallation, operation and maintenance of this product and follow the manual. Please keep this manual properly.5Installation instructions for EACF -101B CCTV camera stationEnglishEATON TMY0024 August 2024 ContentCopyright Statement ...........................................................................................................................2T rademark statement ..........................................................................................................................2Quality Guarantee ...............................................................................................................................3Security Assurance ..............................................................................................................................3Notice .................................................................................................................................................4Ex structure instruction ......................................................................................................................71.0 General . (7)1.1 Type and model ..........................................................................................................................71.2 Features .....................................................................................................................................81.3 Scope .........................................................................................................................................81.4 Mechanical data .........................................................................................................................81.5 Electrical data .............................................................................................................................81.6 Service condition .......................................................................................................................81.7 Electrical safeties (standard atmospheric pressure) ..................................................................82.0 Installation & debugging . (9)2.1 Cautions.....................................................................................................................................92.2 Wall mount installation ..............................................................................................................92.3 Grounding .................................................................................................................................92.4 Wiring .......................................................................................................................................93.0 T roubleshooting ...........................................................................................................................104.0 Transportation and storage .. (10)4.1 Cautions in hoisting and transportation ...................................................................................104.2 Storage condition, duration and cautions ................................................................................105.0 Specification of internal camera module ..................................................................................10Annex 1: Table of poisonous and harmful substances or elements .. (11)6Installation instructions for EACF -101B CCTV camera stationEnglishEATON TMY0024 August 2024 Safety RequirementPlease read this Instruction Manual carefully before installation and operation of this product.1. Safety cautions in installation•Cut off power supply before any maintenance or repair of the product.•Avoid opening of this product in environment where oil smoke, heavy dust, high temperature or dewing may exist. These will cause the decrease of the image definition.•Connect the cables according to the requirement indicated in the Instruction Manual, or fault may happen.•Protect the flame proof joint in maintenance; avoid any metal fragment or other substances get access in the internal chamber.•No disassembly or modification allowed.2. Construction Safety•The protective regulations on construction spot shall be followed strictly.•Measurement shall be carried out immediately when any security risks found to eliminate the risks, stop construction if necessary.•All kinds of safety facilities shall be inspected, calibrated or repaired in the event of severe weather.• The ice, fog, rain and snow shall be removed before opening.•Alert area shall be set, and a person shall protect thearea when protective casing and other safety facilities are constructed or dismantled.•Work high above the ground may require in installation of this product, the operating personnel shall be qualified.3. Power supply requirements•Local electrical safety standard shall be followed in installation and service of this product.•Convenient de-energizing device shall be adopted for immergence cutting off.• Check if the power supply is suitable for operation before start.•Protect the power cable from trample or compressing, especially for the plug, socket and joint out from devices.•Explosion-proof measurement is necessary for Ex products.4. Service condition requirements•Please do not focus the camera to hard light (such as lamp or sunlight), which will cause too bright of the image, it will not malfunction but it will affect the operational life of the CCD (or CMOS).•Transport, operate and store this product in applicable temperature and humidity range. Do not locate it in wet, overheated (over +60℃), extreme cold(less than -30℃)environment or area with strong electromagnetic radiation or power lighting conditions.•The product shall be protected from any entry of water or other conductive fluid, which may damage the internal electrical element.• Avoid overheated, the product shall be well ventilated. •Avoid damage caused by compressing or violent vibration in transmission, storage or operation.•The product shall be well packaged as new product or equivalent in transmission.• We suggest using this product with Surge Protection Devices.•Internal and external grounding shall be reliable.5. Operation & maintenance requirements•There is no user serviceable part inside of camera enclosure. Don’t dismantle this product unless it’s required for repair or maintenance.•Do not touch the front glass of the camera or internal camera lens directly. If it’s necessary to do cleaning please use soft cloth with alcohol to wipe gently.•The camera image sensor may be damaged by laser beam which shall be avoided.•Soft cloth with alcohol or neutral detergent shall be used for camera body cleaning regularly. Corrosive agent or abrasive cleaner cannot be used which may bring damages onto the camera body.• This camera is explosion proof which shall be installed and repaired by authorized individuals. When replacement component is required please contact the manufacturer.6. Environmental protection•For components of the products made by our company may pollute the environment, such as PCB, electrical elements, plastic and lubricant, collection and control measurement shall be taken in maintenance and scrapping of the products. These pollution sources shall be delivered to the government for further treatment, no casually discard allowed, avoid any adversative effect to the environment.7. Special announcement• Some pictures in this manual is a diagram for reference only, if the picture does not match with the real product, the real product is the standard °•Cooper Yuhua remains the right to modify the content andtechnical specifications of the product in this Instruction Manual without any form of notification when the product updates, there may exist little differences after updating.•Y ou can get the latest software and description document by consulting the customer service department.•Any problem in operation of this product, please contact the distributor or customer service department.•We always try to make this instruction manual as perfect as we can, but there still may be some de-tolerance between the real data and the data we provide, if you have any questions or disputes, please refer to our company for finally explanation.• The operator or user shall be responsible for damages or losses caused by misuse or operations do not comply with this manual.7Installation instructions for EACF -101B CCTV camera stationEnglishEATON TMY0024 August 2024 Ex structure instruction•The maximum surface temperature will no more than 80°C in normal operation.•Toughed glass is adopted in observation port, it has passed the impact and thermal shock test.•IP66/IPX8(1.2M/45min )(The equipment has been separately tested against the requirements of IEC 60529);NotesWhen the ordered configuration is non ex version please disregard the sections related to ex instruction in the manual.1.0 Generalmanufactured according to EN IEC60079-0:2017, IEC 60079-1:2014 IEC 60079-31, EN60079-31:2014. It is used in the hazardous areas which are classified as Group I, II, III, (Ex db I Mb, Ex db [ib] I Mb, Ex db IIC T6 Gb, Ex tb IIIC T80°C Db) containing a combustible dust atmosphere or the combination of either. The product has the characteristics of small volume, light weight, and ease of installation. It can be used in mine, onshore and offshore in Oil & Gas, marine, wind, chemical and other industrial areas.All associate technical document, drawings and samples of EACF -101B series explosion-proof integrated camera are tested and certified by ExTC, the certification number is IECEx ExTC 21.0013X, and are also tested and certified by Bureau of Indian Standards, the certification number is BIS: R-41268585.Specifc Conditions of Use•Some flamepaths are with higher design criteria than the tables in the standard and require the repair facility to contact the manufacturer regarding repair and overhaul requirements.•The user shall ensure that all input and output electrical and optical sources are protected using a method listed in IEC60079-0.•When selecting cable glands and cables the following requirements shall be met:a. The minimum gland service temperature shall be 85 °Cb. The minimum continuous operating temperature of thecable shall be 90 °CEssential Health and Safety RequirementsEssential Health and Safety Requirements (EHSRs) are covered by the standards listed at item 9.1.1 T ype and modelExplanationEA CF -101 BDesign version Design codeEx product code, F stands for Ex-proof Fixed Camera Company code, EATON8Installation instructions for EACF -101B CCTV camera stationEnglishEATON TMY0024 August 2024 Model:EACF -101B IP Code:IP66IPX8 (1.2M/45min) (The equipment has been separately tested against the requirements of IEC 60529)Ex marking:Ex db I Mb Ex db [ib] I Mb Ex db IIC T6 Gb Ex tb IIIC T80°C Db Certificate numbers:IECEx ExTC 21.0013X BIS: R-412685851.2 FeaturesEACF -101B series explosion-proof integrated camera set integrates high-performance colour camera, Ethernet IP connectivity and also common communication protocols. It will give you clear and bright images even in low-light conditions, it plays an important role in security system.Its compact design, lighter, smaller and suitable for fastdeployment and places with very limited space underground, tunnel, etc. EACF -101B is ideal for coal mining monitoring application.1.3 ScopeThis product is applicable for Group I, II, III, (Ex db I Mb, Ex db [ib] I Mb, Ex db IIC T6 Gb, Ex tb IIIC T80°C Db) hazardous areas that explosive dust may exist and hazardous areas that both the explosive dust and gas mentioned above exist.1.4 Mechanical dataMaterial:stainless steel 316L Ingress protection:IP66 and IP68(1.2m / 45min)Finish:Polished or powder coated External dimension:215.5(L) x 177(H) x 131(W) mm Unit weight:<4.5KG Package weight:<5.5KGInput voltage:12VDC ± 10% or 12VDC IS Maximum current:≤1.6AConsumption:≤21W when max ambient temperature is +40°C Network video signal output Output via CAT5e/ CAT6Connection8-core network interface,3-core power interface1.6 Service conditionAtmospheric pressure 80~110KPa Ambient temperature -40°C ~+60°C Relative humidity≤95%RH(+25°C)1.7Electrical safeties (standard atmospheric pressure)Insulation resistance: at voltage of DC500V , the resistancebetween the power in terminals and the enclosure is no less than 100 MΩ;Voltage withstand test: adopt voltage of 1500V , 50Hz at the power in terminals and the enclosure for 1 minute, no break down or arc.9Installation instructions for EACF -101B CCTV camera stationEnglishEATON TMY0024 August 2024 2.0 Installation & debugging2.1CautionsCautions before installation and in service Check the following items before installation:c. Check if there is a certificate of conformity numberd. Check if the application area indicated in the Ex marking issuitable for the intend location e. Check if there is any crack or other defect that maydamage the Ex performance f. Check if there are internal and external grounding Cautions in service:a. It’s not suggested for users to dismantle this product atwill, please follow the Instruction.b. The power must comply with requirements specified in 5.c. Please use this product in conditions (atmosphere pressure,temperature and humidity) specified in chapter 1.6.d. Since Ex product is very special, debugging with powerbefore installation if available.e. DO NOT OPEN WHEN ENERGIZED!f. The yield stress of the fastener elements of each part of theflame proof enclosure must be at least equal to 700 N/mm 2.2.2 Wall mount installationFigure 2.2.2 Optional Wall mount bracket of EACF-101B2.3 Grounding Internal and external grounding shall be well connected and reliable.2.4WiringThe product has the following wiring methods, please select one of the wiring methods according to the purchased specifications.IP camera with POEIP camera +12VDC inputIP camera +12V IS input10Installation instructions for EACF -101B CCTV camera stationEnglishEATON TMY0024 August 2024 3.0 Troubleshootingphenomenon analysissolutionNo imagePower cut offCheck the power supply Open curcuit of signal wire Check the signal wire Camera malfunction Contact the manufacture Lens malfunction Contact the manufacture4.0 Transportation and storage4.1Cautions in hoisting and transportationPackaged product can be delivered in all modes of transportation but without direct rain or snow.4.2 Storage condition, duration and cautionsThis product can be stored for one year in environment of temperature range: 0℃~+40℃ and humidity no more than 90%.5.0 Specification of internal camera moduleRated voltage:12V±10%Dissipation power:≤10W11Installation instructions for EACF -101B CCTV camera stationEnglishEATON TMY0024 August 2024 Annex 1: Table of poisonous and harmful substances or elementsComponent Poisonous and harmful substances or elementsLead (Pb)Mercury (Hg)cadmium (Cd)chromium VI (Cr6+)Polybromide (PPB)Polybrominateddiphenyl ethers (PBDE)Stainless steel 304/316L ○○○○○○Casting component ○○○○○○PCB ○○○○○○Movement ○○○○○○Connection cable ○○○○○○Power supply (if applicable)○○○○○○Support (if applicable)○○○○○○Accessories ○○○○○○Remark:1. Symbol ○ means the content of the poisonous, harmful substances or elements in the component (homogeneous material) is lowerthan the limit specified in the standard;2. Symbol × means the content of the poisonous, harmful substances or elements in the component (some certain homogeneous material) is more than the limit specified in the standard SJ/T11363-2006. Leakage or mutation of this poisonous, harmful substances or elements will not happen in the environmental life and will not harm the user’s health or properties. Treatment of this poisonous, harmful substances or elements can not carried out by user selves, please deliver it to the appointed department according to the local laws or regulation.EatonNo.189 Liuyanghe Rd, Xinbei District, Changzhou 213031,Jiangsu, China.Tel: +86 (0) 519 8158 9122Website: /yuhua-cctv© 2024 EatonAll Rights Reserved Publication No. TMY0024 Issue B August 2024Eaton is a registered trademark. All other trademarks are property of their respective owners.Technical Data TMY0024Effective August 2024CONFIDENTIAL —For internal use only by Eaton andauthorized distributors.This information is intended to provide acomparative analysis between Eaton’sproducts and those of other manufacturersbased on the similarities and dissimilaritiesbetween product offerings. It is not intendedto replace specific product literature forEaton products. Information contained in thisliterature about other manufacturers’ productis from written material and/or published, ormade available by the manufacturers.。

伊顿 重型液压系统安装和操作说明书

伊顿 重型液压系统安装和操作说明书

Eaton®June, 1995 Heavy Duty HydrostaticsInstallation &Operating InstructionsConstant Speed Control2Operating Instructions for Constant Speed Control(The valve package, speed sensor and electronic control box are installed by following the instructions and diagrams ona 12 VDC system.)1.The motor will remained stopped if: A) The manual control valve is in the center position; B) The switch on the elec-tronic controller is in the “OFF” position.2.The direction of the motor rotation is controlled by the manual control handle. The electronic controller does not affect the direction of motor rotation.3.The speed of the motor is determined by the position ofmanual control handle when the electronic controller is in the “NORMAL” position. With the switch in the "normal" position,the manual control handle has the same (normal) effect on motor rotation as it does when there is no electronic controller on the pump.4.With engine at minimum rpm and the manual control handle displaced from center enough to cause the drum to rotate at least two revolutions per minute (rpm), placing the controller switch in the “AUTOMATIC” position will cause the drumspeed to be controlled automatically. (The manual control handle may be placed all the way forward or reverse without affecting the speed at which the motor is automaticallycontrolled). Drum speed will be limited to approximately one and 11/2 rpm.5. Drum rotation can be stopped or started with an electrical switch wired across the "remote" terminals (in place of the electrical jumper strap which may have been across the terminals when the controller was received). The switch can act as a remote switch by attaching it to an electrical cable extending from the controller to the back of the truck or other location within 100 feet of the controller.Note:The controller switch must be in the “NORMAL” positionto enable the remote switch to control the motor. Also note that the remote switch must be in the “ON” position to empower motor rotation.The electronic transit mixer control requires the use of an Eaton motor with the digital speed sensor option to monitor the speed of the hydraulic motor. The digital speed sensor (PN 106768)has a three pin connector that mates with the wiring harness connector shown on page 5.Screw the digital speed sensor into the motors’s end cover until it touches the shaft. Unscrew the sensor until the flats are parallel with the motor shaft (see figure 3).To provide running clearance between the motor shaft and speed sensor, unscrew the speed sensor an additional 1/2 turn.The total amount the speed sensor is unscrewed must not exceed 270˚.Tighten the sealing hex nut against the end cover and torque it to 14Nm [10 lb-ft ]*. Make sure that the sensor flats are still parallel with the motor shaft.*Caution: More torque than the specified amount may permanently damage the sensor.Installing the Digital Speed Sensor5˚3Electrical CableUse an oil resistant, weather resistant cable such as industrial type SJOW, 2 wire, AWG size 18 or heavier.A molded assembly with the connector molded on the cable will have superior resistance to weather and washing. Route the wires in a protected area and secure them frequently to prevent snagging.ConnectorsThe pump connectors must meet DIN 43650 specification such as Hirschmann GDM 209, IMEX # MPM-182-09-N or equivalent. The cable to connector joint must be weather tight. The connector lug cavity should be filled with an electrical corrosion resistant grease. NOCO Company,NCP–2 battery corrosion preventative works well. The speed pick-up has a weather pack connector, #12015793.ConnectionsThe polarity of the solenoid and speed sensor wiring is interchangeable on the pump and motor connections.Constant Speed Control Installation RequirementsThe solenoid with the external tube fitting must have one wire going to the control box lower terminal strip marked “solenoid” (see wiring diagram).MountingReplace the S1 orifice under the controller following the instructions below. The solenoid valves must be oriented on the pump as shown. Failure to do so will result in bending the tube assembly unnecessarily, causing erratic operation of the control. Remove the two plugs on the manual control and mount the valve package with the fittings provided. The plug on the pump housing isreplaced with the fitting provided and the tube is connected to it. Tighten all fittings to 22 Nm[16 lb-ft].FailuresSee attached troubleshooting. In the event of an electrical or solenoid failure, the particular solenoid can be overrid-den by turning the screw on the end in about 11/2 turns.Note: The orifice size is stamped on the orifice in thousandths of an inch, example: 21 = .021 in.Orifice Removal and Installation1. Place the .021 inch orifice in the ‘S1’ Orifice pocket so the size is visible.2 Stake the orifice in three places with a center punch.3 Insure that the orifice is properly seated after staking.4 Reinstall the manual control valve with a new gasket and thecontrol line attached. Torque the controller mounting bolts to 122 Nm[16 lb-ft].Orifice Pockets S2S1PGasket Surface of Control ValveTrouble Shooting GuideProblem Cause Corrective Action Motor will not run with the Control lever centered.Move manual control lever one-inchswitch in NORMAL or(or more) from the center position.AUTOMATIC position.Loose or corroded wire Tighten and/or clean theattached to POWER (+12)connection and secure the wire.or GROUND (-12)terminal on the controller.Modulating valve Remove valve and clean outstuck open.debris or replace valve.Solenoid bad.Replace solenoid valve.Control and/or secondary Remove and clean holes in orifices.orifice plugged.Fuse blown in controller.Remove and replace fuse. Check wiring forshort from solenoid to ground. Exchangecontroller with known good unit. Checksolenoid coils on valves for shorts.NOTE: To override control system and restoremotor rotation, turn the screw in until thevalve is seated.Incorrect wiring.Insure the jumper or remote switch is attachedto the correct terminals.Incorrect wiring.Insure the 2 solenoid connections arenot reversed.Motor will not rotate when No electrical power to the Change position of remote switch to ON.the controller switch is in modulation / controlthe NORMAL position.solenoid because theremote switch is OFF.4Trouble Shooting GuideProblem Cause Corrective ActionMotor speed changes very Bypass Solenoid Valve Remove and clean Solenoid Valve spool.slowly (that is, speed stuck shut or orifice(s)Re-assemble valve and test for spool movement changes from highest to a clogged.when 12 volts are applied to the two solenoidstop takes more than three terminals. If spool does not respond, install a seconds with warm oil) when new solenoid valve. If system continues tothe controller switch is in respond slowly, orifice(s) may be partiallythe NORMAL position.clogged. Inspect orifices in the manualcontrol valve and clean holes if necessary.Incorrect plumbing.External tube should connect the solenoid tothe S1 port and not to the charge pressureport on the side of the pumpMotor speed higher than the Defective sensor Replace sensor.speed the controller is set on the motor.for (when the controllerswitch is in the Loose connection or Tighten screws / nuts and/or replaceAUTOMATIC position).broken wire in sensor cable.sensor cable.Sensor located too far Check clearance between the tip of thefrom spline of shaft inside sensor and the surface of the spline. Providethe motor.proper clearance (.003 to .005) by carefullythreading sensor in until the tip touches thehighest point on the spline on the shaft andthen rotate the sensor 20˚counter-clockwise.Torque the jam nut to 19 N·m [14 ± 1 lb ft].CAUTION: More torque than the specified amountmay permanently damage the sensor!Motor speed uneven in Bypass solenoid not Check wiring to BYPASS SOLENOIDAUTOMATIC mode of closing in AUTOMATIC the solenoid should have electricaloperation and motor speed mode.power (12 VDC) when the controllerchanges as quickly in switch is in the AUTOMATIC position.AUTOMATIC as inNORMAL mode.Secondary orifice missing.Remove manual control valve and install orifice. Automatic speed control is not Either the 021 orifice Inspect orifices in the manual control and clean working. Drum runs at what-manual control is plugged or holes if necessary. Remove and clean solenoidever speed the manual control the solenoid is stuck.valve spool. Re-assemble valve and test for spoolis set at.movement when 12 volts are applied to the twosolenoid terminals. If spool does not respond, install anew solenoid valve.5© 2008 Eaton Corporation All Rights Reserved Printed in USADocument No. E-PUPI-TI010-E Supersedes 04-513January 2009EatonFluid Power GroupHydraulics Business USA 14615 Lone Oak Road Eden Prairie, MN 55344USATel: 952-937-9800Fax: 952-294-7722/hydraulicsEatonFluid Power GroupHydraulics Business Europe Route de la Longeraie 71110 Morges SwitzerlandTel: +41 (0) 21 811 4600Fax: +41 (0) 21 811 4601EatonFluid Power GroupHydraulics Business Asia Pacific11th Floor Hong Kong New World Tower 300 Huaihai Zhong Road Shanghai 200021 ChinaTel: 86-21-6387-9988 Fax: 86-21-6335-3912。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

明阳风电1.5MW风电液压系统使用说明书版本号:A编制:孟令旗校对:杨勇审核:赵宏日期:2008.12伊顿流体动力(上海)有限公司目录1 范围 (1)2液压系统总成 (1)2.1液压系统组成 (1)2.2 液压泵站主要工作参数 (1)2.2.1 油泵电机组 (1)2.2.2 油箱 (1)2.2.3 供电要求 (1)2.2.4 液压工作介质 (1)2.3外形及安装说明 (2)2.3.1 液压站总成外形尺寸 (2)2.3.2 外形安装尺寸 (2)2.4 泵站运输储存 (2)2.5泵站油液油温 (2)3液压系统功能说明 (2)3.1 总则 (2)3.2 功能原理 (2)3.2.1 泵组 (2)3.2.2 主轴刹车 (2)3.2.3 主轴刹车监控 (3)3.2.4 偏航刹车 (3)3.2.5 手动泵 (3)3.3 液压原理图 (4)3.4 油箱及附件功能说明 (5)3.4.1 液位控制 (5)3.4.2 温度控制 (5)3.4.3 污染控制 (5)4 运行维护 (5)4.1检测 (5)4.2 维护保养 (5)4.3记录 (6)5 故障排除 (6)5.1电机无法启动 (6)5.2 泵站压力不足,刹车不能正常工作 (6)5.3刹车不能正常卸压 (6)5.4刹车钳速度太慢 (6)5.5刹车钳速度太快 (6)5.6电气元件无信号 (7)附件1 泵站外形图 (8)附件2 电气原理图-1 (9)附件3 电气原理图-2 (10)附件4 电气接线盒 (11)附件5 压力设定 (12)附件 6 元件清单 (13)附录资料附录 (14)1. 范围本使用说明书适用于228P0100DWG/08液压系统(以下简称液压系统)。

本使用说明书规定了液压系统的使用方法,常规保养和常见故障的处理方法。

2. 液压系统总成2.1 液压系统组成本液压系统由液压泵站,以及相关的阀组、电控箱、管路和附件等组成。

2.2 液压泵站主要工作参数:2.2.1油泵电机组泵型号:WP03B1B 012 R 22 NA 124 N最大工作压力:255 bar输出流量:V=1.2 ccm/r,Q=1.8L /min手动泵型号: HP10-21A-0-N-A最大工作压力: 207 bar排量: 7.4 ccm/s电机型号: M2QA80M4B-B5 3x400V/690V-50HZ输出功率:0.75 KW转速:1420 rpm2.2.2 油箱有效容积: 10L液位液温检测:液位开关,70℃液温报警2.2.3 供电要求电动机电源为:三相 AC400V, 50HZ控制电源和电磁铁电源为: DC24V2.2.4液压工作介质液压用矿物油(建议32或46号)或客户指定油液,客户指定液压油需征求伊顿工程师认可。

2.3 外形及安装说明2.3.1液压站总成外形尺寸:泵站:470mm(L) x 492mm(W) x 595mm(H),详细尺寸见附件1泵站外形图。

2.3.2外形安装尺寸安装孔位尺寸长x宽:448 x 270mm安装孔大小为4 xΦ12,进出油口大小为1/4“。

详细尺寸请见附件1 。

2.4 泵站运输储存泵站出厂采用整体集装式包装,运输过程中应保证泵站部件不损坏。

运输前清理油箱内部,保持清洁。

泵站在运输和起吊过程中油箱内不充油。

蓄能器在运输过程中需要卸掉预充气压力。

泵站必须储存于室内,清洁、干燥环境。

长时间储存需要定期检查包装完整性,清洁度。

2.5 泵站油液油温泵站开始工作时,检查液位和液温,保证油箱油位不低于最低位,油液温度在合理范围。

3. 液压系统功能说明3.1总则本液压系统专门为1.5WM风力发电机的主轴刹车、偏航刹车系统设计开发。

3.2功能原理(液压原理图请参见3.3节)3.2.1泵组·液压系统由齿轮泵(2)为系统提供压力和流量。

齿轮泵装在油箱液面以下,由电动机(4)经联轴器(3)带动。

泵及电机参数请见2.2.1。

·系统压力由压力传感器(P2)监控,当系统压力低于压力传感器设定的压力时,电机启动,给系统打压,当系统压力高于压力传感器设定压力时,电机停机。

·单向阀(17)的作用是,当电机停机时,阻止液压油反向流回油箱。

电机停机时,通过蓄能器(A1)提供系统压力,保持系统压力平稳,并能防止电机反复启停。

3.2.2 主轴刹车·电机启动,达当系统压力时,电磁换向阀(24)失电状态,电磁换向阀(25)失电状态,阀24导通,阀25断开。

压力油作用与刹车钳,主轴刹住。

·刹车钳内作用压力由减压阀(27)和溢流阀(16.3)控制在设定值,保证刹车钳正常工作。

·动作电磁换向阀(25)为得电状态,阀25导通,刹车钳内压力迅速卸掉,刹车钳松开。

注意:一般情况下阀25和24同时动作,否则主轴刹车松开时,主轴刹车系统内仍然有油液流动,造成没必要的能源损失。

3.2.3主轴刹车监控压力继电器(P6)监控主轴刹车内压力,当主轴刹车内压力超过10bar时,反馈一个报警信号。

3.2.4偏航刹车·电机启动,达到系统压力时,电磁换向阀(22)失电状态,电磁换向阀(23)失电状态,阀22和阀23均为断开状态,压力油作用于刹车钳,偏航系统刹住。

·动作电磁换向阀(22)为得电状态,阀22导通,通过溢流阀(22.1)将刹车钳内压力迅速降低至设定值,保持刹车钳内有一定的背压。

·动作电磁换向阀(23)为得电状态,阀23导通,刹车钳内压力油和油箱导通,偏航系统刹车钳内压力迅速下降,达到快速卸压作用。

注意:电磁换向阀23导通时,电动机停机,否则会造成没必要的能源损失。

3.2.5手动泵电机停机或者掉电状态时,可以使用手动泵给系统打压。

手动泵压力同时作用于主轴刹车和偏航刹车。

·主轴刹车卸压时需要电磁换向阀(25)动作,保证阀25处于电连通状态,或者可以采用手动操作进行动作。

·偏航刹车卸压时需要电磁换向阀(22和23)动作,要保证阀22、23处于电连通状态,或者采用手动操作进行动作。

3.3液压原理图3.4 油箱及附件功能说明:油箱用于存储液压系统所需的工作介质,同时起到冷却和支撑作用。

油箱上布置液位计、液温计、空滤器等液压附件。

3.5.1液位控制油箱的液位控制由液位液温计(1a)控制。

液位液温计用于指示油箱的液位高度和系统油液温度。

当油液液位低于特定液位时,液位控制器发讯,系统停机。

3.5.2温度控制油箱的温度控制由液位液温计(1a)控制。

当温度超过设定值(如70℃)时,温度控制器发讯,液压系统停机。

3.5.3污染控制油箱的污染控制由空气滤清器(1b)、高压过滤器(15)、回油滤器(30)组成。

空气滤清器用于向油箱内注油,且起过滤空气、油液中杂质的作用。

高压滤器、回油滤器主要用于保证整个液压系统的油液清洁度,过虑精度为10μ,带有目视压差发讯器和旁通阀。

当滤芯堵塞时,发讯器发讯提示操作者更换滤芯。

注意:当滤芯堵塞时,请立即更换,否则将会损坏液压系统。

4. 运行维护4.1 检测·开机前,用测压工具检测蓄能器内压力,如果压力没达到系统要求,则用充氮工具对蓄能器进行充气,达到指定压力时为止。

·检查油箱内液位高度,液位应保持在正常高度,如果油位过低,利用滤油小车给油箱注油,注满为止。

点动泵-电机组,核对电动机旋向,旋转方向应为顺时针方向(电动机的风扇端看)。

·启动泵组,对系统管路进行放气处理,待泵-电机组运行平稳后,按原理调整好各溢流阀、减压阀的最大工作压力,严禁超调。

确保无异常后,才可以进行相关动作操作。

注意:各溢流阀和减压阀出厂前设定好,如需更改参数,请与EATON公司联系。

·运行时随时观察压力表的数值,如有异常,请立即停机检查。

4.2 维护保养·系统使用介质为矿物液压液,整个液压系统的污染度要求达到NAS7级。

·正常使用周期,应设专人对系统进行维护保养,定期(6个月)检查油液的污染状况,并应有油样的污染度检测报告,必要时更换液压油。

·定期(6个月或一年)进行一次泵站的全面检测和维护,保证阀、电气元件、滤器等处于正常工作状态。

4.3 记录泵站在出厂时进行相关阀的设定和性能试验(详见系统试验大纲、试验报告),正常使用周期,运行、维护过程中要做好记录,包括检测报告、故障报告及相关处理报告等。

5. 故障排除5.1 电机无法启动·检查油箱的液位、油温是否正常;·检查电气供电部分(包括动力电源和控制电源)及电器接线是否正常;·检查电机是否损坏。

5.2 泵站压力不足,刹车不能正常工作·检查电机是否转动,方向是否正确;·检查溢流阀16.1压力设定是否正确,压力传感器P2设置是否适当;·检查泵的出口是否漏油严重;·检查刹车钳,确保刹车钳没有故障。

5.3 刹车不能正常卸压·手动操作电磁换向阀,检查能否正常卸压;·检查油液温度是否过低,油液温度过低容易造成卸压缓慢。

5.4 刹车钳速度太慢·检查刹车系统里是否有空气;·检查油液清洁度和粘度,过滤器是否有破损。

5.5 刹车钳速度太快·检查油液温度是否太高;·检查蓄能器预充气压力是否正确;·检查节流塞是否匹配。

5.6电气元件无信号·检查电气元件是否损坏;·检查电气接线是否正确,电气接线盒内接线是否松动;·检查电气元件设置是否正确。

附件1 泵站外形图附件2 电气原理图-1附件3 电气原理图-2附件4 电气接线盒附件5 压力设定客户:明阳风电有限公司合同号: TGZ-LCH001/08销售:李超泵站:228P0100DWG/08压力设定:序号名称设定压力偏差单位16.1 溢流阀 190 +/-5 bar16.2 手动泵溢流阀 190 +/-5 bar27 减压阀 95 +/-3 bar16.3 溢流阀 110 +/-5 barA1 蓄能器 120 +/-5 barA3 蓄能器 50 +/-2 bar22.1 背压溢流阀 45 +/-2 barP6 压力继电器 10 +/-1 bar设定:日期:伊顿流体动力(上海)有限公司附件6 元件清单备注:主要元件详细参数请见资料附录。