菲特18倍AHD高清机芯规格书
Omega FV100 FV100-T流量计与温度传感器使用说明书

e-mail:**************For latest product manuals:FV100/FV100-T Series Installation & Operation Manual on Vortex Shedding Flowmeter &Temperature (optional) TransmitterShop online at User’sGuideCONTENTSSubject Page Specifications (3)Operation (4)Applications (4)Using this Manual (5)Model Plate Examples (5)Name Plate Features...........................................................................5/6 Installation.. (6)Electrical/Wiring/Grounding (7)Wiring Diagrams (7)DC Power Supply Voltage Requirements (8)Configuration/Setup.............................................................................8/9 FV100-T Indicators. (10)Model Codes (10)Pressure Drop Data (10)Cabling.................................................................................................3/ 10 Installation Dimensions........................................................................11/12SpecificationsMaximum operating pressure: 300 PSIG (20 Bar)Minimum operating pressure: See page 6 & 10 (Pressure Drop Charts)Maximum operating temperature (fluid and ambient): 185°F (85ºC), 186°F to 210°F (85ºC to 99ºC) with reduced rating of the solid state relay.Minimum operating temperature (fluid and ambient): 35°F (2ºC).Maximum Flow: Meters may be over ranged, occasionally, up to 125% of capacity without damaging the meter****Output is clamped at 21mA, 6.3% over range, display will indicate up to 125% FS Capacities: 3/4" 25 GPM (95 LPM); 1" 50 GPM (190 LPM); 1 1/2" 100 GPM (380 LPM);2" 200 GPM (750 LPM)Process Connections: NPT femaleWetted Parts: Brass, PVDF & VitonEnclosure Rating: Type 1, 3, 4, 12, & 13, IP65Caution: The unit shall be supplied by a SELV (separated extra-low voltage) source inaccordance with CSA Standard C22.2 No.1010.1-92 Annex H.Display: 3 digit LED digital display, 0.3" highEnvironmental conditions: This device has been designed for use in Installation category I, pollution degree 4, at altitudes up to 2000 meters (6560 ft.), either indoors or outdoors as defined in CSA Standard C22.2 No.1010.1-92.Flow (electrical)Accuracy: ± 5% of Full ScaleAnalog Output: 4-20 mA (600 ohm @ 24 Vdc) proportional to flowResponse Time: 1.5 seconds to 63% of step changeRepeatability: ± 0.25% of actual flowAlarm Output: Low flow, Solid State SPST Relay, rated to 125 mA @ 30 Vdc, up to 185° F,*50 mA @ 30 Vdc between 186° F & 210° F (85-99° C)Alarm Deadband: 5% of full scaleAlarm State:NO or NC above setpoint (selectable)Electrical Connection: 5-pin micro dc male connectorTemperature (electrical)Accuracy: ± 1% of Full ScaleAnalog Output: 4-20 mA (600 ohm @ 24 Vdc); 4 mA= 32° F (0° C) to 20 mA = 212° F (110° C) Response Time: 1.5 seconds to 63% of step changeRepeatability: ± 0.25% of actual temperatureAlarm Output: High temperature, Solid State SPST Relay, rated to 125 mA @ 30 Vdc, up to 185° F, *50 mA @ 30 Vdc between 185° & 210° F (85-99° C)Alarm Deadband: 2% of full scaleAlarm State: Same as selected for FlowOPERATIONFV100 is an inline flow meter that utilizes the vortex shedding principle. The fluid strikes a bluff body generating vortices (eddies) that move downstream. The vortices form alternately, from one side to the other. A piezoelectric sensor housed in a sensor tube directly downstream of the bluff senses the pressure zones created by the vortices. The sensor generates a frequency directly proportional to the vortices (flow). The pulses are then amplified by the circuit board and converted to a 4-20 mA output, which is also linear with flow. Flow can be displayed on the LED display in either GPM or LPM. Selection of the preferred units of measure is made from two white front panel push buttons. There is also a solid state relay output that can be set for a low flow contact from 15% to 90% of full-scale flow. The relay can be configured to be NC (normally closed) or NO (normally open) at flow (above set point). It will change state on decreasing flow upon reaching the setpoint.FV100-T meters combine temperature measurement with the flow measuring features of FV100 Series. The housing utilizes a temperature sensor housed in a small thermowell directly downstream of the flow sensor. FV100-T meters display temperature or flow on the LED display. Temperature can be displayed in either degrees Fahrenheit or Celsius and is selectable from the two white front panel buttons. There is a 4-20 mA output proportional to temperature and a solid state relay that can be configured for a high temperature set point. The relay function will be the same as selected for flow, normally closed or normally open, below set point, since it is a high alarm. So, you have two transmitters in one - flow and temperature.APPLICATIONSFV100/FV100-T can be used on low viscosity clean or dirty water-like liquids that are compatible with brass, PVDF & Viton. Metered fluids should not include long fibers or a significant level of abrasive solids. Bluffs are replaceable, as are the sensors, should abrasive wear occur over time. Typical applica-tions will be for cooling loops using water, 50% solutions of glycols, and water soluble machine coolant (up to 10%). These applications are found in most process industries, including rubber, steel, fabrication, manufacturing, refining, paper, chemical, food, petrochemical and power. They cannot be used on flammable liquids or gases including air.NOTE: If this equipment is used in any manner not specified herein, the protection provided by the equipment may be impaired.Cleaning: These meters do not require any special cleaning of the external surfaces. If cleaning is desired, do not use any strong solvents, detergents, or chemicals. Brushing away accumulations of dirt or wiping with a cloth and water is suggested.USING THIS MANUALTo use this manual, you will require the model code, which can be found on the nameplate of the meter, as shown on the example below. See page 10 for “Model Codes.” The Model Code will allow you to determine the minimum & maximum flow capabilities for each as well as related pressure drops.All FV100 or FV100-T meters are equal in terms of features and functions. The only difference is the flow capacity of the various sizes.MODELPLATE EXAMPLESFEATURES: FV100 SeriesINSTALLATIONThere are no upstream or downstream piping requirements to achieve the operating specifications given herein. The meters may be installed in any position as long as good piping installation requirements are adhered to for best results. This includes proper support of adjacent piping to minimize inherent vibra-tions produced within the system. Unions of the same pipe size and full port isolation ball valves may be installed for ease of removal and servicing of equipment, if required. Meters should be placed in hori-zontal, slightly ascending runs or vertical runs to prevent entrained air from accumulating in the meter. They should not be placed at the highest point in the piping for this same reason. Piping system should be filled slowly to prevent water hammer from damaging sensor. The meter sensor can also be damaged by reverse flow.Isolation ball valves, when used, should be in the full open position. Throttling valves should always be placed downstream of the meter, a minimum of 10 pipe diameters downstream.Teflon®tape or pipe sealant can be used in mounting the meter to the piping when using good technique. Teflon®tape, if not applied properly to the connecting piping, can become caught on the bluff and affect the flow measurement.Use of diaphragm or piston pumps will affect metering performance, unless they are installed with a properly sized pulsation dampener and pressure control valve, to minimize pulsating flow. The piping system must create some backpressure on the meter to allow vortex formation and to prevent cavitation, especially at full flow. Minimum required back pressure is 10 PSIG at max flow and 70° F (21° C). Higher back pressures are required at elevated temperatures and occasional surges to 125% of max flow. This situation will not be encountered in most installations. If while increasing the flow, the signal or displayed flow appears to drop off, but reappears when flow is reduced, contact OMEGA to determine back pressure requirements to extend the flow range to the capacity of the meter.Electrical/Wiring/GroundingElectrical Service: General PurposeElectrical Classification: Non-hazardous Type 1, 2, 3, 4 (equal to IP 65), 12, & 13Power Requirements: 24 VDC (10-30 VDC) @ 80 mAElectrical Connections: 5-Pin micro style for FV100 or 8-Pin micro style for FV100-T, DC Cabling: 5 or 8 Pin DC female shielded cable (do not connect shielding at the panel)Grounding: Note, that DC and Chassis Grounds are internally connected to eliminate electrical noise. If this poses a problem with your control wiring, please contact UFM for an alternative solution.Current Output: 4-20 mA (Note: Use of a 250 Ohm, 0.1%, 1/2 watt precision resistor will produce a 1-5 VDC signal for voltage input receivers)Solid State Relay: Optically isolated, current limited to 125 mA @ 30 VDC up to 185° F (85° C), de-rated to 50 mA @ 30 VDC between 186° & 210° F (86° C to 99° C)WIRING DIAGRAMS (Pin Configurations)DC Power Supply Voltage RequirementsCONFIGURATION (Setup)FV100 comes pre-calibrated and pre-configured in Gallons Per Minute, with the Solid State Relay set for 0 flow, which inactivates the relay. To change the engineering units displayed to LPM, reset the solid state relay for a minimum flow condition, or change the relay function (nc-normally closed or no-normally open) requires a simple reconfiguration. By powering up the meter, it can be reconfigured or checked at the bench or installed position.To configure the FV100 display for GPM or LPM, press the SET button so that the LED next to the desired engineering unit is lit. To configure the set point, or alarm function, hold the MENU button down until the display indicates “flo”, then “AL”, then release it. The LED display will indicate zeros or a set point. Change the setting, by pressing the MENU button. Each time it is pressed, it will step the set point upwards, holding it down will ramp the set point up quickly until the desired set point is ap-proached, then pressing discreetly will step it up to the desired setting. At the highest setting for each meter capacity, it will roll over to 0. Then as the MENU button is pressed it will step or ramp up if held down. Once the desired set point is displayed, use the SET button to enter the value.If no set point is required, then select 0 with the SET button - this will inactivate the relay, as well as the local LED indicator, which flashes on reaching the set point. The two LED indicators that are adjacent to GPM & LPM flash when the flow drops to or below the set point. If GPM has been selected, it will remain on solid and the LPM indicator will flash. The opposite occurs when LPM is the selected unit of measure displayed.CONFIGURATION (Setup) continued...The next parameter, relay function, will automatically appear. It may indicate “nc”, normally closed, or “no”, normally open. Pressing the MENU button will change the relay function from one to the other. To select the desired relay condition, merely press the SET button. The relay function selected is at the normal flow condition, above set point. So, by selecting “no”, the relay will be open above the set point and close on reaching the set point or lower. Conversely, if “nc” is selected, the relay will be closed above the set point and open at or below set point.Once the relay function is set, the meter will return to the run mode. If no flow is present, the meter should display zeros and the LED adjacent to the unit of measure not selected will be flashing to indicate a low flow condition (unless a set point of zero was selected).FV100-T includes the features of FV100 plus temperature. FV100-T has a second set of LED’s adjacent to the SET button. One is labeled F, for degrees Farenheit, and the second C, for degrees Celcius.To setup the flow portion of FV100-T, the flow variable must be displayed. Pressing the MENU button one time, toggles between the displayed variables of flow and temperature. Press the MENU button once if temperature is the displayed variable. Then complete the setup for the flow variable as, described above under FV100.To configure the temperature portion of FV100-T , press the MENU once, if the temperature variable is not displayed. Temperature, since it is being measured on power up, will be displayed as degrees F or C dependent upon the status of the LED indicators adjacent to the two units of measure. To enter a set point, hold the MENU button down until “t”, then “AL” are displayed, consecutively. The display will then indicate the set point. To change, press the MENU button to step the value upward, or hold the MENU button down to quickly ramp up the setting, releasing as the desired value is approached, and then pressing incrementally until the set point is reached. Then press the SET button to enter the se-lected value. Again, as in the flow set point, if the set point is passed, continue holding the MENU button down and it will roll over to zero and continue increasing until released and incremented slowly to the desired value. After selecting the set point the meter will return to the run mode.****NOTE: The relay function for temperature is the same as selected for flow. If the “nc”, normally closed condi-tion is selected for flow, it will also function the same way for temperature. The relay function (status) is always at the normal condition. So, if “nc” is selected, the relay will be closed above the flow set point and below the temperature set point. That is because we are normally looking for a low flow condition and a high temperature condition in cooling applications. When either set point is reached for flow or temperature, its respective relay will change state. The set points, when selected in either GPM or LPM and F or C, will automatically con-vert to the correct value, if the other unit of measure is selected.FV100-T LED IndicatorsThe LED’s adjacent to the engineering units of GPM, LPM, F, & C have two functions. The first is to indicate the process variable being displayed and its respective engineering unit, the second to indicate alarm conditions. If temperature is being displayed, say 75 F, then 75 will appear in the display and the LED adjacent to F will be lit. If the temperature would increase to its respective set point, then the actual value will be displayed, the F LED will remain lit and the LED adjacent to C would begin flashing. If, at the same time, there is a low flow condition, both LED’s next to GPM & LPM will also flash - indicat-ing a flow fault also, so that you can press the MENU button to verify the flow rate.In either case, if flow or temperature is the displayed value, when a fault condition occurs on the nondisplayed value, the two indicator LED’s associated with that variable will both flash to providea local indication of a fault. The solid state relays will still function independently, also regardless of the variable being displayed. As will the 4-20 mA outputs.MODEL CODESInstallation DimensionsInstallation Drawings, 3/4" & 1"INInstallation Drawing, 1 1/2" & 2"INWARRANTY/DISCLAIMEROMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANT Y does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. T his WARRANT Y is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs.OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND W HATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.RETURN REQUESTS/INQUIRIESDirect all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RET URNING ANY PRODUCT(S) T O OMEGA, PURCHASER MUST OBTAIN AN AUT HORIZED RET URN (AR) NUMBER FROM OMEGA’S CUST OMER SERVICE DEPART MENT (IN ORDER T O AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA:1.Purchase Order number under which the productwas PURCHASED,2.Model and serial number of the product underwarranty, and3.Repair instructions and/or specific problemsrelative to the product.FOR NON-WARRANTY REPAIRS,consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA: 1. Purchase Order number to cover the COSTof the repair,2.Model and serial number of the product, and3.Repair instructions and/or specific problemsrelative to the product.OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.OMEGA is a registered trademark of OMEGA ENGINEERING, INC.© Copyright 2004 OMEGA ENGINEERING, INC. All rights reserved. T his document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.Where Do I Find Everything I Need for Process Measurement and Control?OMEGA…Of Course!Shop online at TEMPERATUREⅪߜThermocouple, RTD & Thermistor Probes, Connectors, Panels & AssembliesⅪߜWire: Thermocouple, RTD & ThermistorⅪߜCalibrators & Ice Point ReferencesⅪߜRecorders, Controllers & Process MonitorsⅪߜInfrared PyrometersPRESSURE, STRAIN AND FORCEⅪߜTransducers & Strain GagesⅪߜLoad Cells & Pressure GagesⅪߜDisplacement TransducersⅪߜInstrumentation & AccessoriesFLOW/LEVELⅪߜRotameters, Gas Mass Flowmeters & Flow ComputersⅪߜAir V elocity IndicatorsⅪߜTurbine/Paddlewheel SystemsⅪߜTotalizers & Batch ControllerspH/CONDUCTIVITYⅪߜpH Electrodes, Testers & Accessorie sⅪߜBenchtop/Laboratory MetersⅪߜControllers, Calibrators, Simulators & PumpsⅪߜIndustrial pH & Conductivity EquipmentDA T A ACQUISITIONⅪߜData Acquisition & Engineering SoftwareⅪߜCommunications-Based Acquisition SystemsⅪߜPlug-in Cards for Apple, IBM & CompatiblesⅪߜDatalogging SystemsⅪߜRecorders, Printers & PlottersHEATERSⅪߜHeating CableⅪߜCartridge & Strip HeatersⅪߜImmersion & Band HeatersⅪߜFlexible HeatersⅪߜLaboratory HeatersENVIRONMENTALMONITORING AND CONTROLⅪߜMetering & Control InstrumentationⅪߜRefractometersⅪߜPumps & TubingⅪߜAir, Soil & Water MonitorsⅪߜIndustrial Water & Wastewater TreatmentⅪߜpH, Conductivity & Dissolved Oxygen Instruments。
Intensifier T Series HD-TVI 1080p 2MP 传统摄像头说明书

DIMENSIONSFEATURESHTINTT5T – Grey housingSPECIFICATIONSImage Sensor.................. 1/3” Progressive Scan CMOS, 2MP Minimum Illumination....... 0.001 lux (Sens-up X32) Effective Pixels................ 1984 (H) x 1105 (V) Total Pixels...................... 2000 (H) x 1121 (V) Scanning System............ Progressive S/N Ratio......................... More than 50dB Output Resolution............ 1920x1080 @ 30fps Video Output.................... 1.0Vp-p / 75 OhmsElectronic Shutter............ Auto / Manual (1/30 – 1/30,000 sec.) Day / Night....................... Auto / Color / BW / External Communication............... UTC (up the coax) Power............................. 12VDC / 24VACPower Consumption........ 150mA (DC), 2W (AC) Operating Temperature....14° F – 122° FUnit Dimensions.............. 2.5”(W) x 2.2”(H) x 4”(L) Unit Weight...................... 1.5Ibs.Certifications.................... FCC, RoHS Signal Distance............... Up to 1600 feet(depending on coax quality)*• Full HD resolution over coax (HD-TVI) • Supports up to Full HD 1080p @ 30fps • True WDR operation• Superior low-light performance• Amplify existing light with no distance limitation• PRESET (Indoor/Outdoor/Lowlight/Hallway/Lobby/Elevator) • Full OSD operation thru on-board control and UTC (up the coax) • Additional 960H analog output • Signal distance up to 1600 feet* • 12VDC/24VAC dual voltage operation • 5 year warrantyOSD M ENU T REEEXPOSURE• B /W• E XTERN• L OW• M IDDLE• H IGH• S HARPNESS • G AMMA • M IRROR • F LIPDAY / N IGHTWHITE B AL.SPECO D NRIMAGEEXIT• B RIGHTNESS• S HUTTERBACKLIGHT• H LC• B LC• W DR• A UTO• A WB• C OLOR G AIN• A CE• D EFOGSYSTEM• C OM.• I MAGE R ANGE • C OLOR S PACE• F RAME R ATE• I NTENSIFY• A GC• C OLOR• P RIVACYLENS MOTION • O UTPUT • L ANGUAGE• C OLOR B AR• R ESET• C AMERA T ITLE• F REQLENS : S elect t he l ens t ype (ALC/ELC)EXPOSURE : A djusts e xposure s eEngs.B RIGHTNESS : A djusts i mage b rightness. (0~ 20) S HUTTER : A uto / M anual S huTer c an b e s electable -‐ A UTO : S huTer c an b e s electable a utomaVcally.-‐ F LICKER(Flicker L ess) : S elects t his w hen p icture flickering.-‐ M anual : C ontrols t he s huTer s peed m anually f rom 1/30 ~1/30000 I NTENSIFY : S ets t he d esired m ulVple o f t he d igital e xposure l ength. (OFF/x2 ~ x 32)A GC(Auto G ain C ontrol): A djusts t he A GC l evel. (0~10)OSD M ENU D etailsPRESET MODE• INDOOR • OUTDOOR • LOW LIGHT • LOBBY • HALLWAY • ELEVATORMAIN SETUP Side ViewFront ViewBack panel ConfigurationUnit : inchTVI OutCVBS Out (Analogue)Power In (12VDC/24VAC)OSD joystick4” L2.5” W2.2” HSpeco T echnologies i s c onstantly d eveloping p roduct i mprovements. We r eserve t he r ight t o m odify p roduct d esign a nd s pecificaRons w ithout noRce a nd w ithout i ncurring a ny o bligaRon. R ev. 160809OSD M ENU D etailsDAY / N IGHT : A djust D ay / N ight o pRons . C OLOR : A lways C olor m ode. B /W : A lways B /W m ode.-‐ A NTI-‐SAT. : A djusts t he A nV S aturaVon l evel (0~20) E XT : p lease d o n ot u se t his m ode f or t his i temA UTO : D ay / N ight i s s witching a utomaVcally b y A GC l evel. -‐ A NTI-‐SAT. : A djusts t he A nV S aturaVon l evel (0~20) -‐ A GC T HRES : A djusts A GC T HRES (0~20) -‐ A GC M ARGIN : A djusts A GC m argin (0~20)-‐ D ELAY : A djusts t he c hanging d elay V me (LOW/MIDDLE/HIGH)WHITE B AL. : A djusts w hite b alancing o pRons.A WB : i t g oes t o o pVmized c olor l evel a utomaVcally.C OLOR G AIN : S ets t he d esired C olor G ain v alue (0~20)S PECO D NR : U ses t o r educe t he b ackground n oise i n a l ow l uminance e nvironment w ith 2D + 3D filtering s ystem.BACKLIGHT : A djusts b acklight o pRons.W DR : W DR i lluminates d arker a reas o f a n i mage w hile r etaining t hes ame l ight l evel f or b righter a reas t o e ven o ut t he o verall b rightness o f i mages w ith h igh c ontrast b etween b right a nd d ark a rea -‐ A djusts t he W DR W eight (LOW/MIDDLE/HIGH) * C VBS o ut c annot a djust t his f uncVon.B LC : P roduces a c learer i mage o f a n o bject d arkened b y s trong b acklighVng. -‐ H -‐POS : A djusts t he h orizontal p osiVon(0~20) -‐ V -‐POS : A djusts t he V erVcal p osiVon(0~20) -‐ H -‐SIZE : A djusts t he h orizontal b lock s ize (0~20) -‐ V -‐SIZE : A djusts t he v erVcal b lock s ize (0~20)H LC : U ses t o c ontain e xtremely b right a reas s uch a s f rom c ar h eadlight, t he l ight c an b e m asked o ut m uch o f t he o n-‐screen d etails. IMAGE : A djusts v arious i mage o pRons.S HARPNESS: A djusts s harpness l evel. I ncreasing t his v alue, t he p icture o utline b ecomes s tronger a nd c lear. (0~10) G AMMA : S ets t he d esired G amma v alue. (0.45 ~ 0.75) M IRROR : C hange t he v ideo d irecVon h orizontally. F LIP: C hange t he v ideo d irecVon p erpendicularly.A CE (D-‐WDR) : U ses a d igital w ide d ynamic r ange t o b alance d ark a nd o ver s aturated a reas w ithin t he i mage.D EFOG : A cVvated t his m ode w hen t he v ideo o r t he w eather i s f oggy. P RIVACY : U sed t o h ide r egions o f t he i mage. -‐ Z ONE N UM : S elects t he z one n umber u p 15. -‐ Z ONE D ISP : S elects d esired z one w ith O N o r O FF -‐ H -‐POS : A djusts t he h orizontal p osiVon(0~60) -‐ V -‐POS : A djusts t he v erVcal p osiVon(0~40) -‐ H -‐SIZE : A djusts t he h orizontal s ize(0~40) -‐ V -‐SIZE : A djusts t he v erVcal s ize(0~40)-‐ Y -‐LEVEL : A djusts t he y ellow c olor l evel (0~20) -‐ C B L EVEL : A djusts t he b lue c olor l evel (0~20) -‐ C R L EVEL : A djusts t he r ed c olor l evel (0~20)SYSTEM : A djusts v arious c amera s ystem o pRons. O UTPUTF RAME R ATE: S elect t he f rame r ate 30fps/60fps a ccording t o t he v ideooutput m ode. F REQ C OM.-‐ C AM I D : S ets t he c amera I D f or t he R S-‐485 (0~255)-‐ B AUD R ATE : S ets t he b aud r ate f or t he R S-‐485 (2400~115200). I MAGE R ANGE C OLOR S PACEC OLOR B AR : M anufacturer’s o pVonL ANGUAGE : S ets t he d esired O SD l anguage C AMERA T ITLER ESET: P ress w ith l ong t o r eset a ll s elngs t o f actory d efaults.MOTION : A djust m oRon d etecRon s eEngs.-‐ S ENSITIVITY : S ets t he d esired o f “MoVon” (0~20)-‐ W INDOW T ONE : A djusts t he w indow t one v alue (0~60) -‐ W INDOW U SE : A djusts t he w indow s elng s ize (0~3) -‐ W INDOW Z ONE : a cVvate o r d eacVvate m oVon w indow -‐ D ET H -‐POS :Adjusts t he h orizontal p osiVon(0~60) -‐ D ET V -‐POS : A djusts t he v erVcal p osiVon(0~40) -‐ D ET H -‐SIZE : A djusts t he h orizontal s ize(0~60) -‐ D ET V -‐SIZE : A djusts t he v erVcal s ize(0~40) -‐ A LARM : S elect A larm b etween O N o f O FFHTINTT5T – Grey housing。
菲特EFFIO10X一体机机芯650TVL FTZ10P65-T2

10X(1/3〞)EFFIO-E/S/P系列一体机机芯式样书ModelFTZ10P48-T2/C2 FTZ10N48-T2/C2 FTZ10P65-T2 FTZ10N65-T2 FTZ10P65-T2E FTZ10P65-T2EWProduct size chartSpecificationsZoom CameraFTZ10P65-T2EWFTZ10P65-T2EFTZ10P65Model FTZ10P48700TVL700TVLResolution 480TVL650TVLCommunication mode RS232Signal system PAL/NTSCCCD 1/3" SONY Exview HAD CCD IIEffective pixels 500(H)×582(V) PAL:960(H)×582(V) / NTSC:967(H)×494(V)Day & Night Colour/ B&W /AutoMini.Illumination 0.01Lux(infra LED on)Sync System Inter-syncVideo output CVBS Output (1Vp-p-p75 Ω)SNR ≥48dBLensFNO./Focal Length F/2 f=5mm~5mmIRCUT IRCUTIRCUT OptionalAUTO IRIS ——FOV H:51.8°(W)~5.86°(T)V:39.1°(W)~4.4°(T)M.O.D 0.5m(W)~1m(T)FunctionsOSD Display SupportLens Initialization AutoExposure Mode Auto/ManualAWB Auto/Indoor/Outdoor/Manual Focus Mode Auto/ManualPicture Effects Auto/Color/B&W/NegativeBacklight Compensator SupportContrast Adjust Saturation AdjustMirror Image Support(HOR)Digital Zoom —— SupportSupport Freeze ——Support Rollovers ——WDRDual-scanD-WDRWDR D-WDR2D/3D-DNR DNR 2D-DNRGeneral SpecificationsSize 38.6(W)* 41(H)* 64.6(L) mmWorking Temp./Hygro. ﹣10℃~50℃,10%RH~60%RHStorage Temp./Hygro. ﹣20℃~60℃,10%RH~80%RHPower Voltage DC 12V±10%Power consumption 2.5W MAXNet Weight 100gCommand ListPin assignmentThe Connect Pins Functions Table: the order of 1 to 9 pin location and the following table.cdefghijkPin NO. Name Specificationc RxD CMOS 3.3V (low: max 0.8V, high: min 2.8V) Read Dated TxD CMOS 3.3V (low: max 0.8V, high: min 2.8V) Send Datee GND (for RxD&TxD)f DC IN 12V±3Vg GND (for DC IN)h VBS OUT 1.0V±0.2Vi GND (for VBS OUT)j NCk GNDCommand List(注明:命令中红色标记项为可选项,根据产品型号对应功能。
美国艾顿公司滤芯技术产品说明说明书

10
10
Refinery Overview and Application Portfolio
11
11
Refinery Flow Diagram
H2
Sour Gas
Amine Treating
Fuel Gas H2S
Claus Reactor
Sulfur
Gas
Gas Processing
Merox Treater
This is a photographic template – your photograph should fit precisely within this rectangle.
Filtration Technology for Oil & Gas
EATON FILTRATION (JAPAN) Ltd. Sales Manager. Shuji Yamaguchi.
world
4
4
Eaton’s growth through acquisitions
Ronningen-Petter (Sep. 2006)
• Application focused engineering in a range of industrial markets
• Range of unique solid-liquid separation and self-cleaning products
9
Markets & Industries Served
Marine
• Gearboxes • Shipbuilding Industry • Tankers
Refrigeration
Machines
菲涅尔透镜 说明书

型号:7707-5 型号:7708-1 型号:7803 焦距:25 焦距:25 焦距:20角度:180°角度:79.8°角度:89°尺寸:26×75 距离:10m 距离:7m尺寸:44.8×56.82 尺寸:25×39型号:8001-1 型号:8001-2 型号:8202 规格:Ф55 焦距:30 焦距:16焦距:30 角度:120°角度:120°角度:120°距离:10m 距离:12m距离:10m 尺寸:48×84 尺寸:25×62 尺寸:38×68SUNSTAR自动化/TEL:0755-********FAX:0755-********E-MAIL:**************型号:7707-5 型号:7708-1 型号:7803 焦距:25 焦距:25 焦距:20角度:180°角度:79.8°角度:89°尺寸:26×75 距离:10m 距离:7m尺寸:44.8×56.82 尺寸:25×39型号:8001-1 型号:8001-2 型号:8202 规格:Ф55 焦距:30 焦距:16焦距:30 角度:120°角度:120°角度:120°距离:10m 距离:12m距离:10m 尺寸:48×84 尺寸:25×62 尺寸:38×68型号:7707-5 型号:7708-1 型号:7803 焦距:25 焦距:25 焦距:20角度:180°角度:79.8°角度:89°尺寸:26×75 距离:10m 距离:7m尺寸:44.8×56.82 尺寸:25×39型号:8001-1 型号:8001-2 型号:8202 规格:Ф55 焦距:30 焦距:16焦距:30 角度:120°角度:120°角度:120°距离:10m 距离:12m距离:10m 尺寸:48×84 尺寸:25×62 尺寸:38×68型号:7709-1 型号:7709-2 型号:8202-6焦距:7.6 外径:Ф17 角度:90° 内径:Ф15距离:5m 尺寸:Ф21型号:001 型号:2091 型号:8731-1 外径:Ф55 外径:Ф55 规格:Ф45.2 内径:Ф44内径:Ф44角度:180°距离:10m角度:120°Feinier lens菲涅尔透镜SUNSTAR传感与控制/TEL:0755-********FAX:0755-********E-MAIL:**************SUNSTAR自动化/TEL:0755-********FAX:0755-********E-MAIL:**************SUNSTAR传感与控制/TEL:0755-********FAX:0755-********E-MAIL:**************SUNSTAR商斯达实业集团是集研发、生产、工程、销售、代理经销、技术咨询、信息服务等为一体的高科技企业,是专业高科技电子产品生产厂家,是具有10多年历史的专业电子元器件供应商,是中国最早和最大的仓储式连锁规模经营大型综合电子零部件代理分销商之一,是一家专业代理和分銷世界各大品牌IC 芯片和電子元器件的连锁经营綜合性国际公司。
Philips 26英寸宽屏液晶电视Pixel Plus HD 26PFL7532D说明书

Philipswidescreen flat TV with Pixel Plus HD26"LCD integrated digital26PFL7532DTurn up your viewing experiencewith Integrated Digital TunerWith this TV you can now enjoy the benefits of digital TV, Electronic Programme Guide and digital quality content. At the same time, you can also watch superb pictures with Pixel Plus HD clarity and details.Vivid, natural and razor sharp images•HD LCD WXGA display, with a 1366 x 768p resolution •Integrated Digital Tuner for DVB-T reception•HD Ready for the highest quality display of HD signals •Pixel Plus HD for better details, depth and clarity•3D combfilter separates colours for a razor-sharp image Exciting and lifelike sound•Incredible Surround™ for enhanced audio enjoyment Slim, stylish design to complement your interior •Compact and slim design that fits in every room Designed for your convenience•1000-page Hypertext for instant fast access to teletext For advanced performance•2 HDMI inputs for full digital HD connection in one cableHighlightsLCD WXGA display, 1366 x 768pThis WXGA display with state-of-the-art LCD screen technology gives you widescreen HD resolution of 1366 x 768p pixels. It produces brilliant flicker-free progressive scan pictures with optimum brightness and superb colours. This vibrant and sharp image will provide you with an enhanced viewing experience. Integrated Digital DVB-T tunerThe integrated DVB-T tuner lets you receive Digital Terrestrial TV to watch or record. This means you do not need an additional set-top box or additional cables.HD ReadyEnjoy the exceptional picture quality of High Definition pictures and be fully prepared for HD sources like HDTV set-top boxes and Blu-ray discs. HD Ready is a protected label that offers picture quality beyond that of progressive scan. It conforms to strict standards laid out by EICTA to offer an HD screen that displays the benefits of the resolution and picture quality of a High Definition signal. It has a universal connection for both analogue YPbPr and uncompressed Digital connection of DVI or HDMI, supporting HDCP. It can display 720p, and 1080i signals at50 and 60 Hz.Pixel Plus HDPixel Plus HD is a picture processingtechnology that enables viewers to watchcontent that is vivid, natural and real. Theresult is superbly razor sharp pictures withincredible details and depth from any HDsource.3D CombfilterThe 3D combfilter separates brightness andcolour signals better in 3D domain to eliminatecross-colour, cross-luminance and dot-crawldistortion - all of which detract from yourviewing pleasure. The 3D digital combfilterperforms field-by-field comparisons of thetelevision image to accurately separate thecolour from the black-and-white informationand remove both horizontally and verticallyhanging dots, as well as dot crawl. The result isa razor sharp image.Incredible Surround™Incredible Surround is an audio technologyfrom Philips that dramatically magnifies thesound field to immerse you in the audio. Usingstate-of-the-art electronic phase shifting,Incredible Surround mixes sounds from leftand right in such a way that it expands thevirtual distance between the two speakers.This wider spread greatly enhances the stereoeffect and creates a more natural sounddimension. Incredible Surround allows you toexperience total surround with greater depthand width of sound, without the use ofadditional speakers.Compact and slim designThis design style emphasises a slim, compactlook that saves space and fits in anywhere.2 HDMI inputsHDMI makes an uncompressed digital RGBconnection from the source to the screen. Byeliminating conversion to an analogue signal, itdelivers an unblemished image. The non-degraded signal reduces flicker and leads to aclearer picture. HDMI intelligentlycommunicates the highest output resolutionwith the source device. The HDMI input is fullybackwards-compatible with DVI sources butincludes digital audio. HDMI uses HDCP copyprotection. With 2 HDMI inputs you canconnect multiple HD sources, for instance anHD set-top box and a Blu-ray player. Your TVis fully prepared for the HD future.Issue date 2011-08-04Version: 4.1.912 NC: 8670 000 26846EAN: 87 12581 31473 6© 2011 Koninklijke Philips Electronics N.V.All Rights reserved.Specifications are subject to change without notice. Trademarks are the property of Koninklijke Philips Electronics N.V. or their respective owners.SpecificationsPicture/Display•Aspect ratio: Widescreen, 16:9•Brightness: 500 cd/m²•Dynamic screen contrast: 4000:1•Response time (typical): 8 ms•Viewing Angle (H / V): 160 / 150 degree •Diagonal screen size: 26 inch / 66 cm•Display screen type: LCD WXGA Active Matrix TFT•Panel resolution: 1366 x 768p•Picture enhancement: Pixel Plus HD, Luminance Transient Improver, Colour TransientImprovement, Dynamic contrast enhancement, Contrast Plus, 3/2 - 2/2 motion pull down, 3D Combfilter, Active Control, Digital NoiseReduction, Jagged Line Suppression, Progressive Scan•Screen enhancement: Anti-Reflection coated screenSupported Display Resolution•Computer formatsResolutionRefresh rate 640 x 480 60, 72, 75, 85 Hz 800 x 600 60, 72, 75, 85 Hz 1024 x 768 60, 70, 75, 85 Hz •Video formats Resolution Refresh rate 480i 60 Hz 480p 60 Hz 576i 50 Hz 576p 50 Hz 720p 50, 60 Hz 1080i 50, 60 Hz 1080p 50, 60 HzSound•Equalizer: 7-bands•Output power (RMS): 2 x 10 W•Sound Enhancement: Auto Volume Leveller, Incredible Surround, Dynamic Bass Enhancement •Sound System: Nicam Stereo, StereoLoudspeakers •Built-in speakers: 2Convenience•Child Protection: Child Lock+Parental Control •Clock: Sleep Timer, Wake-up Clock•Ease of Installation: Auto Programme Naming, Automatic Channel Install (ACI), AutomaticTuning System (ATS), Autostore, Fine Tuning, Plug & Play, Programme Name, Sorting•Ease of Use: Auto Volume Leveller (AVL), Easy toggle Dig/Analogue modes, Programme List, Side Control, Smart Picture, Smart Sound•Electronic Programme Guide: 8-day Electronic Programme Guide •Remote Control: TV•Remote control type: RC2034301/01•Screen Format Adjustments: 4:3, Movie expand 14:9, Movie expand 16:9, Subtitle Zoom, Super Zoom, Widescreen•Picture in Picture: Text dual screen •Teletext: 1000-page Hypertext•Teletext enhancements: 4 favourite pages, Programme information LineTuner/Reception/Transmission•Aerial Input: 75 ohm coaxial (IEC75)•TV system: PAL I, PAL B/G, PAL D/K, SECAM B/G, SECAM D/K, SECAM L/L', DVB COFDM 2K/8K •Video Playback: NTSC, SECAM, PAL •DVB: DVB Terrestrial*•Tuner bands: Hyperband, S-Channel, UHF, VHF •Number of Pre-set Channels: 100•Tuner Display:PLLConnectivity•Ext 1 Scart: Audio L/R, CVBS in/out, RGB•Ext 2 Scart: Audio L/R, CVBS in/out, S-video in •Number of Scarts:2•Ext 3: S-video in, CVBS in, Audio L/R in •Ext 4: YPbPr, Audio L/R in •Ext 5: HDMI •Ext 6: HDMI•Other connections: Headphone out, CommonInterfacePower•Ambient temperature: 5°C to 40°C •Mains power: 220 - 240 V, 50/60 Hz •Power consumption: 120 W•Standby power consumption: < 1 WAccessories•Included Accessories: Tabletop stand, Power cord, Quick start guide, User Manual, Registration card, Warranty certificate, Remote Control, Batteries for remote control•Optional accessories: Floor standDimensions•Colour cabinet: Black cabinet with High Gloss Black deco•Set dimensions (W x H x D): 682 x 472 x 114 mm •Set dimensions with stand (W x H x D): 682 x 537 x 200 mm •Product weight: 12 kg•Product weight (+stand): 15 kg •Box dimensions (W x H x D): 836 x 212 x 592 mm•Weight incl. Packaging: 18 kg•VESA wall mount compatible: 200 x 100 mm。
Omega FL-1800 流量计系列产品说明书

Para unidades com válvula de controle 316 de aço inoxidável, acrescente o sufixo “-V” ao número do modelo, sob um custo adicional.Exemplos de pedidos: FL1807-V , rotâmetro com válvula de controle 316 de aço inoxidável.U E xatidão de Fundo de Escala de 5% U R epetibilidade de fundode escala de ±1⁄2%U G rande, de 150 mm (5,9")U G ráficos explicativospara ar e água U P eças das partes úmidascom vidro e PVDF U E ncaixes comextremidades usinadas U C onstrução de placa lateral U E ixo de vedação nãorotativoOs medidores de vazão da série FL-1800 da OMEGA ® são projetados para o uso com materiais corrosivos. Esses medidores de vazão especiais utilizam peças em contato com partes úmidas de vidro e PVDF para uma excelente resistência à corrosão onde os rotâmetros padrão seriam inaceitáveis. Por conta da sua construção, esses medidores de vazão podem ser usados com a maioria dos ácidos e bases, além de vários solventes orgânicos.FL-1801, mostrado em escala menor que a real.ROTÂMETROS PARA APLICAÇÕES CORROSIVAS CAPACIDADES: 0,054 a 573 cc/min de água,Série FL-1800B1-27ESPECIFICaçõESEscalas:150 mm (5,9"), 0 a 150 mm com gráficos explicativos para ar e água Exatidão:Fundo de escala de 5% Repetibilidade: fundo de escala de ±0,5% Conexões:horizontal fêmea de ¹⁄₄ NPT Tubos de medição: vidro de borosilicato Flutuadores: vidro Encaixes das extremidades, vedação do eixo:PVDF Placas laterais: alumínio Limitadores dos flutuadores: PTFE Embalagem do tubo: FKM anéis: FKMPressão máxima: 10,34 bar (150 psig) 38°C (100°F)。
Omega FL50000A系列面板安装流量表说明书

ߜ Panel Mount
OMEGA® FL50000A Series flowmeters feature a rugged, one-piece acrylic body, stainless steel internal parts, rear inlet and outlet ports for panel mounting, and excellent accuracy. The stainless steel float guide helps reduce float oscillation and improve overall performance. Permanent screenprinted scales are positioned directly in front of the float for easy reading. For greater versatility and control, FL5000A Series meters may be ordered with an integral flow adjustment valve.
*(50$1< ZZZRPHJDGH 'HFNHQSIURQQ *HUPDQ\
%(1(/8; ZZZRPHJDQO
More than 100,000 Products Available!
7HPSHUDWXUH
Calibrators, Connectors, General Test and Measurement Instruments, Handheld Instruments for Temperature Measurement, Ice Point References, Indicating Labels, Crayons, Cements and Lacquers, Infrared Temperature Measurement Instruments, Recorders, Relative Humidity Measurement Instruments, PT100 Probes, PT100 Elements, Temperature & Process Meters, Timers and Counters, Temperature and Process Controllers and Power Switching Devices, Thermistor Elements, Probes and Assemblies, Thermocouples, Thermowells and Head and Well Assemblies, Transmitters, Thermocouple Wire, RTD Probes
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
18X(1/3〞)AHD高清一体机机芯式样书产品型号
FTZ18SH72-AHD
产品外观图
规格参数
引脚定义
9P FPC 的接口定义是:(第一脚如上图所示位置) ① ②③ ④⑤⑥⑦⑧⑨
菜单
扩展设置命令:
MENU: 菜单
第一页菜单:
LANG EN
ADDR 01
BAUD 9600
OSD-DISP ON/OFF
ADDR-DISP ON/OFF
D-ZOOM ON/OFF
D&N AUTO/COL/BW/CDS
D&N-LV 0~31
N&D-LV 0~31
MIRROR OFF/LR/UD/FLIP
第二页菜单:
AE AUTO)/MANUAL/IRIS/SHUTT
DSS 00
IRIS 08
SHUTTER 00
GAIN 00
AGC 0-31
BRIGHT 0-31
CONTRAST 0-31
SHARPNESS 0-31
SATURATION 0-31
第三页菜单:
ATR OFF/LOW/MID/HIGH
2D-NR 00/01/02/03
3D-NR 00/01/02/03
WB AUTO/ATW/PUSH/HOLD/CRS/FLUO/IN/OUT/MANU/USER RGAIN 00
BGAIN 00
DE-FOG 00/01/02/03
OUTPUT AHD
FORMATE 720/25,720/30,720/50,720/60,1080/25,1080/30 BLC ON/OFF
第四页菜单:
HLC 00
ZOOM 18
DZOOM 01
Command List
FOCUS AF/MF
Z-SAVE ON/OFF
F-RANGE 1.8M
ZDISP-POS LU/RD/RU/LD/LU+1/LU+2/RD-1/RD-2/RU-1/RU-2/LD+1/LD+2
RESET
SAVE-EXIT
操作:
菜单光标上下: ZOOM TELE命令 ZOOM WIDE命令(见标准协议命令)
菜单光标左右: FOCUS NEAR命令 FOCUS FAR命令(见标准协议命令)
菜单上下左右连续操作间隔需200ms以上
翻页操作:在第一页最后一行光标向下则翻到第二页第一行
在第二页第一行光标向上则翻到第一页最后一行
ADDR(地址),(BAUD)波特率 OUTPUT(视频输出格式)修改不立即生效,在退出
菜单后才生效。
ADDR(地址) 和 (BAUD)波特率默认锁定,不可修改
菜单中FOCUS 模式的TRIG为变倍触发(只在变倍完成后会有一次聚焦,然后不
再对焦)
菜单复位功能:进入菜单第二页,光标上下移动到“复位”处,NEAR/FAR进行
复位
复位后地址(ADDR), 波特率(BAUD)和视频输出格式(OUTPUT)会保持进入菜
单之前的值,其他的数据将回复到出厂默认值。
同时会退出菜单。
SONY协议高清命令列表
(注明:命令中红色标记项为可选项,根据产品型号对应功能。
)
Function Command List
标准协议命令:
VISCA Command Setting Values Register Setting:
Exposure Control
Zoom Ratio Optical Zoom
Zoom Ratio Optical Zoom
Title setting
字符索引表(索引号16进制):
编号50H~69H为扩展字符。