L8管理机使用说明书V2.0

合集下载

Model L8 Flotect 流动水平开关说明书

Model L8 Flotect 流动水平开关说明书

Model L8 Flotect ®Liquid Level Switch features a leak proof body and float constructed from tough, durable polyphenylene sul-fide (PPS) which has excellent chemical resistance. Because the liq-uid level snap switch is magnetically actuated, there is no direct mechanical linkage to leak or fail, assuring longer life and decreased maintenance costs. This inexpensive unit is ideal for liquid level alarm, indication or control. Installation is quick and easy — simply install in a horizontal position with the index arrow pointing down. The L8 Flotect ® Liquid Level Control is UL recognized as an indus-trial motor controller per UL standard 508, suitable for mounting in a protected environment. This lightweight switch can be used in nu-merous chemical process, industrial systems and similar applica-tions where process conditions are compatible with polyphenylene sulfide, ceramic 8 and 316 stainless steel. This liquid level switch provides accurate setpoint control of liquids with specific gravities as low as 0.6. This compact and reliable control is designed to han-dle temperatures up to 212°F (100°C) and pressures to 150 psig (10 bar).®SPECIFICATIONSService:Compatible liquids.Wetted Materials:Float and Body: Polyphenylene Sulfide (PPS).Pin and Spring: 316 SS or Inconel ® alloy.Magnet: Ceramic 8.Temperature Limit:212°F (100°C).Pressure Limit:150 psig (10.34 bar).Enclosure Rating:General purpose. WP option is weatherproof.Switch Type:SPDT snap switch. MV option is a SPDT gold con-tact snap switch.Electrical Rating:5A @ 125/250 VAC, 5A resistive, 3A inductive @ 30 VDC. MV option: 1A @ 125 VAC, 1A resistive, 0.5A inductive @ 30 VDC.Electrical Connections:18 AWG, 18˝ (460 mm) long.Conduit Connection:1/2˝ male NPT.Process Connection:1˝ male NPT.Mounting Orientation:Horizontal with index arrow pointing down.Weight:5 oz (0.142 kg).Agency Approvals:CE, UL 508 for US and Canada.Specific Gravity:0.6 minimum.Model L81/2 FEMALE NPT Model L8-WPMODELL8Level SwitchOPTIONS-MV, Gold Plated Contacts,for dry circuits. Rated 1A @ 125VAC;1Aresistive,********************************-INC, Inconel ®Option. Inconel ®alloy replaces standard 316 SS wetted parts. Wetted parts are Inconel ® alloy, ceramic 8, and Polyphenylene Sulfide. Example: L8-INC-WP , Weatherproof Enclosure. Optional housing is phenylpo-lioxide and provides weatherproof protection for electrical wiring.Example: L8-WPINSTALLATION1.The Model L8 Level Switch is designed for use in clean, com-patible process media free from scale, debris and other for-eign material which could collect on the float and impede itsmovement. Build up from such materials will prevent properoperation. See wetted materials list in the specifications toassure compatibility with process liquids.2.Unpack switch and remove any packing material from theswitch and float. Due to variations in fittings and amount ofthread engagement, float must be checked for proper oper-ation during installation.e pipe thread sealant tape or pipe thread sealant to sealthe 1˝ NPT mounting connection. Avoid excess sealantwhich could interfere with float movement. Do not exceed 50ft/lb (40n/m) torque on the switch housing. Damage canresult.4.Install switch in a horizontal position with index arrow point-ing down.5.Wire in accordance with local electrical codes. Lead wirecolor codes are as follows. Black - Common, Red - NormallyClosed, Blue - Normally Open. Normal is the contact condi-tion when liquid level is below the actuation point. Closedcontacts open and open contacts close when liquid level liftsthe float to the actuation point.6.Switch electrical components must be protected from mois-ture at all times. If necessary, install a lightweight, waterproofjunction box over the 1/2˝ NPT threaded stem. Do not placemechanical loading on the switch housing. Permanent dam-age can occur. Use flexible Romex sheathing or equivalent.Inconel®is a registered trademark of Huntington Alloys Corporation.MAINTENANCEThe Model L8 Liquid Level Switch is not field serviceable andshould be returned if repair is needed (field repair should not beattempted and may void warranty). Be sure to include a briefdescription of the problem plus any relevant application notes.Contact customer service to receive a return goods authorizationnumber before shipping.©Copyright 2010 Dwyer Instruments, Inc.Printed in U.S.A. 2/10FR# 82-440881-00 Rev. 3。

L8管理机使用说明书V2.0

L8管理机使用说明书V2.0
L8 管理机使用说明书
1.1 产品说明
序号
产品名称
1 L8 管理机
2 L8 可视管理机
3 L8 彩色可视管理机
1.简介
产品型号 L8-5003 L8-5003V-4G L8-5003VC-50
备注
4〞黑白 CRT 5〞彩色 TFT
1.2 功能特点
(1)可采用总线制传输或 TCP/IP 网络传输方式,LCD 液晶显示屏; (2)内置开关电源,并配有备用电池; (3)配有编程菜单,可设置系统所需要的功能; (5)能与门口主机、室内分机实现双向呼叫对讲; (6)能对门口主机遥控开锁和采集门口主机上的视频信号至管理中心的监视屏上; (7)可调整当前时间、日期; (8)铃声大小可调; (9)具有报警、声光、时间日期提示; (10)可存储 999 条报警信息以备随时查询; (11)配有 RS232 电脑接口,通过管理软件可实现接收远程探头报警、门禁管理、图文发布等功能。
XXX(信息数量)XX:XX XX(时间) XXX(信息序号)XXXX(主机号)–XXXX(分机号) 40(探头报警代码)
0 000 0000XX(分机防区) XXXX–XX–XX XX :X(防区报警时间) 防区代码说明: 000001:第 1 防区 000002:第 2 防区 000004:第 3 防区 000008:第 4 防区 000010:第 5 防区 000020:第 6 防区 000040:第 7 防区 000080:第 8 防区 例如:管理机显示“0005–0301 40 0 000 000020”表示 5 单元 0301 分机第 6 防区控测器报警。
(2)开门检测报警信息
-4-
当主机电锁开锁后,对讲门在开门检测到时未关闭,主机自动向管理中心报警。管理机接收到主机未 关门报警信号时,红色报警指示灯(ALARM)亮并发出报警提示音,电锁检测报警类型号为 2A。如 果是主机开门报警信息,则副主机号项为“0000”。按“阅读”键阅读显示:

立林L8智能化可视对讲系统简易说明书

立林L8智能化可视对讲系统简易说明书

立林L8-5000系统楼宇对讲系统使用手册1、单元主机介绍2、L8系统施工中的网线RJ45头制作方法双绞线分为非屏蔽双绞线(UTP )和屏蔽双绞线(STP )两类,在电磁场干扰比较严重的场所,建议用屏蔽双绞线(STP )。

网线两端水晶头做法相同,都是TIA/EIA-568B 标准。

3、主机编程设置(1)进入/退出编程操作(2)菜单选项说明当主机进入编程态后,连续按“*”键,显示屏上依次出现####、1n1t、####、####、bt=3/4、bd=n/C、rd-A/rdUA、Sg-1/---、bg-A/bgUA、dF-A/dFUA、Lt##、LF-1/2/3/4/23/34/12、t###、### - 、####、C###、d###、n###、U###、SC-A/SCUA、EALL等共21个选项,具体含义如下:4、L8-5000系统编号操作(1)编号操作编号的方式有两种,一种是通过分机来设置(详见分机软开关操作部分)。

另外一种是通过主机编号,方式如下:①主机进入编程态后输入需要发送的分机号码(如0101)②分机按住报警键和开锁键③按下主机保安键,编号成功分机会发出他长“嘟”提示音,主机会发出“嘟、嘟”提示音表明编号成功。

(2)主机删号(删除用户卡)主机进入编程态后,按(4位分机号4位分机号用户密码000*)可删除主机上存储的对应分机的相关信息。

删除该分机号后,主机依然可以呼叫该分机,但是原来注册过的对应该分机号的卡将失效,同时也不能进行密码开锁。

5、主机密码操作(1)密码类别①用户密码:用于密码开锁和对防区撤防操作,适用小区用户。

用户密码可设1-6数字,初始密码为1234。

用户密码忘记则主机进入编程态重新设置。

②系统密码:用于主机进编程操作,系统密码可设1-6数字,初始密码为1234。

用户密码忘记则主机进入编程态重新设置。

(2)更改用户密码:4位分机号用户旧密码用户新密码(3)更改系统密码:*90*系统旧密码系统新密码6、主机感应卡操作(1)卡的类别①功能卡:在待机状态下,刷卡直接进入编程态,适用于系统维护人员。

L8简要调试步骤(单元、联网、软件设置、发卡)

L8简要调试步骤(单元、联网、软件设置、发卡)

L8系统常用设备设置确认主机到主机选择器、主机选择器到视频放大隔离器、进户线线路正常,接通电源,进行以下操作。

一、设置主机相关选项(副主机除了第二项不一样,其他项改成跟主机一样)首先,主机进编程:锁键* 90* 1234 锁键,依次按*键翻阅菜单(共23项),修改菜单的设置,需要修改的选项如下:第3项:8888:此项为主机号,即主机呼叫管理中心机显示的号码。

如5栋2单元,则该项改为0502。

第4项:0000:此项为副机号,正主机不作修改,副主机改为0001、0002……。

第5项:bt=3:此项为拨号位数选择。

若小区的最高楼层有超过10层,建议全部主机改为bt=4。

第16项:n003:此项为安保分机选项,此项改为n000。

第17项:U003:此项为安保分机选项,此项改为U000。

第18项:SCUA:此项为密码开门功能选项。

若需开启,则按任意数字键更改为SC-A。

修改以上所有选项后,依次按*键,直至长嘟一声,屏幕灭掉,设置才能保存。

最后主机退编程:# 锁键锁键二、主机选择器主机接INPUT-1,副主机接INPUT-2,INPUT-3,INPUT-4,这4个口需要通过主机来编号,否则会出现整个单元蓝屏。

方法如下:1、按住主机选择器背后微动开关3秒不放,,听到间隔一声嘀响,放开。

2、主机直接输入0000(不需要进编程),听到间隔两声嘀嘀响3、主机直接输入0001(不需要进编程),听到间隔三声嘀嘀嘀响4、主机直接输入0002(不需要进编程),听到间隔四声嘀嘀嘀嘀响5、主机直接输入0003(不需要进编程),听到间隔一声嘀响6、按住主机选择器背后微动开关3秒不放,停止发出响声即可。

三、分机编号(分机号需要区分单元,通过单元门口机来编号)设置分机号前,一定要先设置主机主机号和其他相关设置,否则此分机将无法正常使用。

编号方法如下:1、主机进编程:锁键* 90* 1234 锁键2、输入要编的分机号,如01013、分机同时按住开锁键和铃铛键4、主机按保安键,分机听到嘟一声,则编号成功,两个键松开。

浪潮存储系统AS500H用户手册V2.0

浪潮存储系统AS500H用户手册V2.0
1.1 关键术语 .................................................................... 9 1.2 必须的部件 .................................................................. 9 1.3 硬件速览 ................................................................... 10 第二章 安装 HBA 卡 .................................................................. 12 2.1 关键术语 ................................................................... 12 2.2 安装 HBA 卡注意事项 ......................................................... 12 2.3 安装 HBA 卡 ................................................................. 12 第三章 配置交换机 .................................................................. 13 第四章 快速安装指南 ................................................................ 14 4.1 机柜准备 ................................................................... 14 4.2 存储系统导轨套件 ........................................................... 14 4.3 安装导轨到机柜 ............................................................. 15 4.4 安装设备到机柜中 ........................................................... 17 第五章 连接控制器和主机 ............................................................ 18 5.1 关键术语 ................................................................... 18 5.2 连接主机须知 ............................................................... 18 5.3 连接主机步骤 ............................................................... 19 5.4 主机通道连接拓扑 ........................................................... 19

MAM-200(变送器控制)八型机控制器说明书V0.1

MAM-200(变送器控制)八型机控制器说明书V0.1
油精分器复位
0000小时
更换油精分器使用时间清零
气过滤器复位
0000小时
更换气过滤器使用时间清零
润滑油复位
0000小时
更换润滑油使用时间清零
润滑脂复位
0000小时
更换润滑脂使用时间清零
最大使用
时间预置
油过滤器
9999小时
设为“0”时,油过滤器时间预警不起作用
油精分器
9999小时
设为“0”时,油精分器时间预警不起作用
气过滤器
9999小时
设为“0”时,气过滤器时间预警不起作用
润滑油
9999小时
设为“0”时,润滑油时间预警不起作用
润滑脂
9999小时
设为“0”时,润滑脂时间预警不起作用
中英文选择
中文
设为“英文”,界面变英文操作
修改用户密码
****
用户可修改用户密码
d)、厂家参数
厂家参数与用户参数的差别在于厂家参数不能查看,修改时只能凭厂家密码修改,修改操作方法与用户参数修改方法一样。主要功能与作用见下表:
注意:配线时,电磁线圈需接突波吸收器
五、控制原理(电气原理图见附图)
(A)、独立控制
(1)、近地自动控制(启停方式:机旁;加载方式:自动)
①、按“I”键起动:(Y—△起动)
控制器上电后有3秒自检,按“I”键不能起动。自检结束后按“I”键主机开始起动。主机起动过程为:KM3得电,KM2得电Y形起动状态延时时间到(Y—△转换时间),KM3失电(KM1、KM3互锁),KM1得电电机△形运行,起动结束。起动过程中,所有电磁阀一直失电,实现空车起动。
机组通电后显示如下界面:
5秒后显示以下主界面:
按“”进入以下菜单选择界面:

海天机械手中文操作篇.

海天机械手中文操作篇.
根据画面,有表示项目全体说明的情况和各按钮说明的情况。
5.4
需要输入位置设定、计时器设定、密码等的数值时,表示数值输入画面。
用数字键输入和用「+」/「-」按钮让数值增减的输入方法。
5.4.1
表示数值输入画面,用数字键可以进行输入。
1按设定项目。(被选择按钮的颜色发生变化)
2按项目,表示数值输入画面。
※注)模内有上下手臂时,如果电源投入后,已经原点复归完了,轴位置全部被设定,即使模内有上下手臂,也能原点复归。
1用自由操作使产品上下手臂或S侧上下手臂移动到与模具不干涉的位置。
2用自由操作使产品上下手臂或S侧上下手臂上升至注塑机的模外。
3确认在模外的位置,实行「7.1原点复归步骤」。
1按设定项目。(被选择按钮的颜色发生变化)
2按项目表示数值输入画面。
3用「+」/「-」按钮输入数值。
用「位变更」按钮,能变更位,在「+」/「-」按钮被表示的位也被变更。
被表示的位,根据选择的项目而不同。
4按「返回」按钮,数值输入画面消失。
5.5
在注释输入画面,输入段取数据文件及段取组的注释。
注释能输入英数字、记号、片假名、平假名。
4.
4.1
取出机的动作大体分为原点复归操作、手动操作、自动运转3类。
4.1.1
取出机返回原点位置。
电源投入时和开始自动运转时必定进行的操作。
操作方法请参照「7.原点复归」
4.1.2
有按模式和教导设定的动作去实行每1动作的手动操作及与设定内容无关实行轴移动的自由操作。
●手动操作
为确认每一个设定内容进行手动操作

模式选择状态表示
表示现在被选择的模式选择按钮的状态。

TongLINKQ81系统管理手册 配置管理

TongLINKQ81系统管理手册 配置管理

TongLINKQ81系统管理手册_配置管理标题:TongLINKQ81系统管理手册 -配置管理一、引言TongLINKQ81系统是一种企业级的数据中心解决方案,其配置管理是系统管理的重要组成部分。

本手册旨在为系统管理员提供有关配置管理的详细指南和最佳实践。

二、配置管理概述配置管理是系统管理的一个重要环节,它涉及对系统组件、系统参数、系统设置以及其他关键信息的控制和记录。

配置管理的目标是确保系统的配置信息与业务需求保持一致,同时确保系统的变更能够得到有效管理和控制。

三、配置管理流程1、识别系统需求:首先需要明确系统的需求,包括硬件需求、软件需求、网络需求等。

这些需求将作为配置管理的基础。

2、制定配置计划:根据识别的需求,制定详细的配置计划,包括系统组件的选型、系统的部署、网络拓扑结构等。

3、配置实施:根据配置计划,进行具体的配置实施,包括系统组件的安装、系统的部署、网络设备的配置等。

4、配置验证:在完成配置实施后,需要进行配置验证,以确保系统的配置信息与计划一致,并满足业务需求。

5、配置记录与审计:对系统的配置信息进行记录和审计,确保配置信息的准确性和完整性。

四、配置管理工具TongLINKQ81系统提供了一系列的配置管理工具,包括:1、系统部署工具:用于自动化部署系统,简化系统的初始化和配置过程。

2、网络配置工具:用于配置网络设备,简化网络配置过程。

3、监控与报告工具:用于监控系统的运行状态,提供系统性能报告和故障诊断。

4、安全控制工具:用于控制系统的访问权限,确保系统的安全性。

五、最佳实践以下是一些关于配置管理的最佳实践:1、制定详细的配置计划,并确保所有相关人员都了解和遵循。

2、在实施配置前,进行风险评估,以确定潜在的问题和风险,并采取相应的措施。

3、对系统的配置信息进行定期的备份和审计,以确保信息的完整性和准确性。

4、在进行重大变更前,进行备份和测试,以避免意外的问题。

5、制定应急预案,以便在出现问题时能够快速响应。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

JP3 红 12V+ 黑 12V白 L+ 黑 L-
白 32VIN
AF+ 绿
V+ 白/棕 V-

棕 V-
+ - 电源12V
电控锁
+ - 电源32V
LAN
白/橙
TXD

RXD
白/绿
光纤收发器

白/蓝
绿
白/棕

JP2 R+
白/橙 R- 橙
AF- 白/绿 T+
蓝 T- 白/蓝
AF+ 绿
V+ 白/棕 V-

JP3 红 12V+ 黑 12V白 L+ 黑 L-
(6)副主机呼叫管理机
-3-
按副主机 键呼叫管理中心,同时主机图像自动传输到管理中心。管理机振铃后摘机对讲,显示 屏显示呼叫副主机号码,在通话中按 开锁 键可开锁。
XXXX–XX–XX〔X〕(日期) XXX(信息数量) XX:XX XX(时间)
GATE No.XXXX(主机号) XXXX(主机号)–XXXX(副主机号)
M.G ID. =XXX (3 位管理机内码) M.G No. =XXXX(4 位管理机号码) SUB SUM =XXX (系统容量)
LAN1
白/橙 橙 白/绿 蓝 白/蓝 绿 白/棕 棕
LAN2
白/橙 橙 白/绿 蓝 白/蓝 绿 白/棕 棕
LAN3
白/橙 橙 白/绿 蓝 白/蓝 绿 白/棕 棕
按“*”键下移,“#”上移,按数字键输入,不按 20 秒后自动退出编程状态,且不保存原先设置参数,按确认键保存并 进入下一屏。 2、进入第二屏:
GATE No.XXXX(主机号) XXXX(主机号)–XXXX(分机号)
例如:管理机显示“GATE No:0004 0004-0201”,表示 4 单元的 0201 分机呼叫中心。
3.3 报警信息阅读操作
管理机在挂机情况下按 阅读 键可查询历次报警的记录。 (1)探测器报警信息
管理机接收到分机防区探测器报警信号时,红色报警指示灯(ALARM)亮并发出报警提示音,如需 查明实际情况,按“*”键即可呼叫该报警分机,同时黄色使用灯(INUSE)亮,探头报警代码为 40。按 阅读 键阅读显示:
0 000 990000 XXXX–XX–XX XX :X(开门报警时间)
例如:管理机显示“0006–0000 2A”,表示 6 单元主机对讲门打开后未关闭。
(3)分机在线巡检信息 当分机在线时,管理中心将接收到分机在线信息,发出报警提示音。分机在线巡检信息代码为 42。按
阅读 键阅读显示:
XXX(信息数量)XX:XX XX(时间) XXX(信息序号)XXXX(主机号)– XXXX(分机号)42(在线代码)
L8主机
电源12V 电控锁
LAN
白/橙
TXD

RXD
白/绿

白/蓝
绿
白/棕

光纤收发器
微机接口
至电脑232端口
红 AF+ 黄 AF绿 TXD+ 蓝 TXD白 RXD+ 黑 RXD-
L8管理机
视频输入
红 电源12V 黑
12V+ 红 12V- 黑
M 蓝T- 白/橙 绿T+ 橙 黄AF+ 白/绿 白R+ 蓝 黑R- 白/蓝 红AF+ 绿
(2)开门检测报警信息
-4-
当主机电锁开锁后,对讲门在开门检测到时未关闭,主机自动向管理中心报警。管理机接收到主机未 关门报警信号时,红色报警指示灯(ALARM)亮并发出报警提示音,电锁检测报警类型号为 2A。如果是 主机开门报警信息,则副主机号项为“0000”。按“阅读”键阅读显示:
XXX(信息数量)XX:XX XX(时间) XXX(信息序号)XXXX(主机号)– XXXX(副主机号)2A(开门报警代码)
1.3 技术参数
显示:16 位 LCD 显示 监视屏:4〞CRT/ 5〞TFT CRT 分辨率:420TV 线 TFT 解晰度:960X234 像素 视频输入:1VP-P/75Ω 通信波特率:2400bps 传输距离:3Km 系统容量:999 台 接线方式:6 芯屏蔽双绞线 输入电压: 130ACV-250ACV 0.16Amax 工作电压:12V 1.5A 工作温度:-10℃~+55℃ 外观尺寸:400×280×125(mm)
按“*”键前进,“#”键后退,按数字键输入,不按 20 秒后自动退出编程状态,且不保存该屏原先设置参数,按确认键 保存并退出编程状态,
3.使用说明
-2-
3.1 显示界面
XXXX–XX–XX〔X〕(日期) XXX(信息数量) XX:XX XX(时间)
3.2 对讲操作
管理机摘机拨号若拨错号可按#键清除或挂机重拨,当管理机拨号完后听到“嘟.嘟”占线音时,表示 系统正在工作,这时候如需要快速呼叫可按“*”键抢线。方框中的中文显示为解释说明。 (1)呼叫分机 摘机显示 No.= 操作:4 位主机号+4 位分机号
4.安全注意事项
4.1 严禁使用没有接地的插头和插座; 4.2 在未切断电源的情况下不要对管理机的各连接线进行拨插; 4.3 不要把管理机放置在靠近热源的地方,保持周围通风良好; 4.4 切勿将水或其它液体泼到管理机上,如不小心发生这种情况,应立即切断电源; 4.5 对于使用不符合国家电工标准的相关电源设备而引起损害,如烧毁等,本公司将不负责。
0 000 00XXXX(刷卡信息) XXXX–XX–XX XX :X(刷卡时间)
3.4 时间日期设置
管理机内的时钟主要用来记录报警的日期和时间,在管理机每次上电的时候都要校正一下时间和日 期,以保证时钟的准确性。在挂机的情况下按 时间/日期 键可选择设置时间和日期。 (1)当显示“TIME = ”时可设置时间
后发出报警提示音,显示屏显示求助分机,摘机自动呼叫该求助分机。分机求助类型号为 41。
XXX(信息数量)XX:XX XX(时间) XXX(信息序号)XXXX(主机号)– XXXX(分机号)41(分机求助代码)
n0 000 000000 XXXX–XX–XX XX :XX(求助时间)
例如:管理机显示“0002–0101 41”,表示 2 单元的 0101 分机求助中心。
例如:管理机显示“GATE No:0003 0003-0031”,表示 3 单元的 0031 副主机呼叫中心。
(7)分机呼叫管理机 分机摘机或按免提键输入“99990000”直接呼叫管理机,管理机振铃后摘机即可通话对讲,并显示对方信 息。
XXXX–XX–XX〔X〕(日期) XXX(信息数量) XX:XX XX(时间)
输入“4 位时间数字” +确认 键(管理机能自动分辨输入日期的合法性),例如输入“1235” + 确
-5-
认 键,表示现在时间为 12 点 35 分钟。 (2)当显示“DATE = ”时可设置日期
输入“8 位日期数字” +确认 键(管理机能自动分辨输入时间的合法性。同时自动更新星期),例如 输入“20021204” + 确认 键,表示今天日期为 2002 年 12 月 04 日。
操作正确即可选通相应分机并振铃,同时黄色指示灯(INUSE)亮。例如:摘机拨“0001 0101”,表示 呼叫 1 号门口主机的 101 分机。 (2)监视主机 摘机显示 No.=操作:4 位主机号+0000
操作即可监视相应主机,同时黄色指示灯(INUSE)亮,并能与门口主机对讲。例如:摘机拨“0002 0000”, 表示监视 2 号主机。 (3)监视副主机 摘机显示 No.=操作:4 位主机号+4 位副主机号
XXXX–XX–XX〔X〕(日期) XXX(信息数量) XX:XX XX(时间)
GATE No.XXXX(主机号) XXXX(主机号)–0000
例如:管理机显示“GATE NO:0001”,表示 1 单元主机呼叫中心。
(”键求助,管理机接收到分机求助信号
3.4 音量调节
当报警音、拨号音、振铃音偏大或偏小时可调节管理机背后的“振铃音” 调节钮。
3.5 图像调节
调节管理机右则的对比度开关和亮度开关调节可视管理机的监视屏图像,使其达到最佳效果。 3.6 电源开关
如管理机不需要工作时,可将电源开关压至“0”端即可;如需要工作时,将电源开关压至“1”端时 即可。
棕V+ 白/棕 灰V-

L8IP网络转换器 光纤收发器
LAN
白/橙 橙 白/绿 蓝 白/蓝 绿 白/棕 棕
光纤收发器
LAN
RXD 白/橙 TXD 橙
白/绿 蓝 白/蓝 绿 白/棕 棕
LAN
RXD 白/橙 TXD 橙
白/绿 蓝 白/蓝 绿 白/棕 棕
2.2 编程设置
进入编程状态操作:时间/日期+9901+确认 1、进入第一屏:
摘机操作正确即可监视相应副主机,同时黄色指示灯(INUSE)亮,并能与副主机对讲。例如:摘机拨 “0003 0031,表示监视 31 号副主机。注:副主机号不能与系统里的分机同一号码。 (4)主机呼叫管理机
按主机的 键呼叫管理机,同时主机图像自动传输到管理中心。管理机振铃后摘机对讲,显示屏
显示呼叫门口主机号码,在通话中按 开锁 键可开锁。
0 000 00FFFF(布撤防信息) XXXX–XX–XX XX :X(布撤防时间)
(5)用户刷卡信息 当用户持有效感应卡在主机上刷卡,管理机中将接收到用户刷卡信息并上传电脑。用户刷卡信息代
码为 B0。按 阅读 键阅读显示:
XXX(信息数量)XX:XX XX(时间) XXX(信息序号)XXXX(主机号)- XXXX(分机号)B0(刷卡代码)
0 000 990000 XXXX–XX–XX XX :X(在线时间)
相关文档