H3C 高端网络产品-可插拔模块手册
H3C S5560-EI系列以太网交换机 快速安装指南-6PW102-整本手册

Installing and removing a power module 安装/拆卸电源模块
! This section is applicable only to switch models that provide power module slots.
LSPM1FANSA LSPM1FANSB
Remove a filler panel 拆卸假面板
1
2
Install a power module 安装电源模块
PSR360-56A/PSR720-56A/PSR1110-56A
Installing and removing a fan tray 安装/拆卸风扇模块
!
This section is applicable only to switch models that provide fan tray slots.本节内容仅适用于采用可插 拔风扇模块的机型。 Make sure the airflow direction of the fan tray is as required by the installation site.请确认风扇模块气 流方向和安装环境的通风要求一致。 Install two fan trays of the same model on the switch.设备必须安装两个相同型号的风扇模块,否则禁 止上电运行。 Make sure the "TOP" mark stays on top when you install the fan tray.安装风扇模块时,请确保“TOP” 丝印朝上。 Make sure all slots have a module or filler panel during the switch is operating. 设备运行过程中,必须确保所有可插拔模块插槽不能为空,请务必安装相应的模块或假面板。 If both fan trays fail during the switch is operating, replace the fan trays within 2 minutes. 设备运行过程中,如果两个风扇模块均出现故障,则必须在2分钟内完成故障风扇模块的更换。 If one fan tray fails and the operating temperature is not higher than 27°C (80.6°F), replace the fan tray within 24 hours, and make sure the failed fan tray is in position before replacing it. If the operating temperature is higher than 27°C (80.6°F), replace the fan tray immediately.设备运行过程中,如果一个风扇模块出现故障,则当环境温度不高于27℃时,必须在24 小时内完成故障风扇模块的更换,且更换前需保持故障风扇模块在位;当环境温度高于27℃时,请立 即进行更换。
H3C S6800系列以太网交换机 规格

附录A 系统特性介绍
表A-1 交换机系统特性
项目
S6800-32Q
S6800-54QF S6800-54QT
外形尺寸(宽×深 440×660× ×高)(单位:mm) 43.6
440×460× 43.6
440×660× 43.6
重量
≤13kg
≤10kg
≤13kg
Console口
• Mini USB
208W
• 双 AC:
213W
• 单 DC:
211W
• 双 DC:
216W
• 单 AC:
360W
• 双 AC:
370W
• 单 DC:
365W
• 双 DC:
380W
• 单 AC:
504W
• 双 AC:
515W
• 单 DC:
508W
• 双 DC:
508W
整机漏电流
满足UL60950-1/EN60950-1/IEC60950-1/GB4943标准
C.1.1 Console口 ····························································································································· C-1 C.1.2 管理用以太网口····················································································································· C-2 C.1.3 USB口 ··································································································································· C-2 C.1.4 SFP+口 ································································································································· C-2 C.1.5 QSFP+口 ······························································································································ C-4 C.1.6 1/10GBase-T自适应以太网端口···························································································· C-6 C.2 指示灯介绍······································································································································· C-7 C.2.1 系统状态指示灯····················································································································· C-7 C.2.2 SFP+口状态指示灯 ··············································································································· C-7 C.2.3 QSFP+口状态指示灯 ············································································································ C-7 C.2.4 管理用以太网口状态指示灯··································································································· C-8 C.2.5 1/10GBase-T自适应以太网端口状态指示灯 ········································································· C-8 C.2.6 风扇模块上的告警指示灯 ······································································································ C-8 附录D 散热系统介绍 ···························································································································· D-1 D.1 S6800-32Q/S6800-2C/S6800-54QT散热系统················································································· D-1 D.2 S6800-4C散热系统 ·························································································································· D-2 D.3 S6800-54QF散热系统 ····················································································································· D-3
新华三SOHO产品手册说明书

新华三SOHO 管理型产品手册客服热线:400-810-0504杭州总部杭州市滨江区长河路466号邮编:310052新华三集团北京总部北京市朝阳区广顺南大街8号院 利星行中心1号楼邮编:100102Copyright2021新华三集团 保留一切权利免责声明:虽然新华三集团试图在本资料中提供准确的信息,但不保证本资料的内容不含有技术性误差或印刷性错误,为此新华三集团对本资料中信息的准确性不承担任何责任。
新华三集团保留在没有任何通知或提示的情况下对本资料的内容进行修改的权利。
CN-202030-20210519-BR-HZ-V2.0SOHO 产品手册02SOHO 产品手册目录CONTENTS01S1850V2系列WEB 管理型千兆交换机03S2600系列全管理型百兆交换机05S5000PV5系列全管理千兆交换机07S1850-X 系列万兆上行交换机08S5000E-X 系列全管理型万兆交换机09桌面防火墙系列产品11解决方案展示S1850V2系列WEB管理型千兆交换机产品定位普遍应用于中小型企业、市县政企、普职教、连锁型酒店等流量数据大,有划分VLAN及子网需要,需要对网络进行适当维护且对数据安全性有一定要求的应用场景;作为组网中的接入层,多端口型号可作为汇聚层设备使用。
S1800系列千兆交换机产品型号端口形态交换容量/包转发率软硬件特性产品尺寸(mm)S1850v2-9P8个千兆电口+1个千兆光口192Gbps/30MppsWEB管理、端口限速、端口聚合/Vlan划分、端口镜像、ACL限速、QoS策略、IGMP V1/V2/V3 Snooping、6KV防雷、端口绑定、动态链路聚266×162×44 S1850v2-10P8个千兆电口+2个千兆光口192Gbps/30Mpps266×162×44S1850v2-10P-PWR8个千兆电口+2个千兆光口192Gbps/30Mpps330×230×44 S1850v2-26P24个千兆电口+2个千兆光口240Gbps/78Mpps440×173×44注:S1850-28P-PWR整机POE供电功率190W,单端口最大供电功率30W产品参数0102S2600系列全管理型百兆交换机产品定位普遍应用于连锁商铺、大中小学校、商务型酒店、政企单位等对数据安全性要求高,有较复杂组网需求,需要多种维护手段维护的应用场景;作为组网中的接入层或汇聚层设备使用。
H3C交换机板卡及模块解读

S过外接 波分复用器,将不同波长的光信号 复合在一起,通过一根光纤进行传 输,从而节约光 纤资源。同时,接 收端需要使用波分解复用器对复合 光信号进行分解。 适用:36 51 56 75 75E 95
对外型号
SFP-GE-LH70-SM1470-CW SFP-GE-LH70-SM1490-CW SFP-GE-LH70-SM1510-CW SFP-GE-LH70-SM1530-CW SFP-GE-LH70-SM1550-CW SFP-GE-LH70-SM1570-CW SFP-GE-LH70-SM1590-CW SFP-GE-LH70-SM1610-CW
接口类型 SC 接口 SC 接口
XENPAK CX4 电口模块
-
10GE 电口 连接器
光模块的传输距离分为短距、中距和长距三种。一般认为 2km 及以下的为短距离,10~20km 的为中距离,30km、 40km 及以上的为长 距离。中心波长指光信号传输所使用的 光波段。 目前常用的光模块的中心波长主要有三种:850nm 波段、 1310nm 波段以及 1550nm 波段。 850nm 波段:多用于短距离传输 1310nm 和 1550nm 波段:多用于中长距离传输
LC 接口
可插拔模块类型 XENPAK(10 Gigabit Ethernet Transceiver Package, 万兆以太网 接 口收发器 集合封装) 模块 XENPAK 光模块 XENPAK LX4 光模块
说明 光转发器(Transponder),可热插 拔 光转发器(Transponder),采用 CWDM 技术,可将光 信号分为 4 路在一根光纤中传输,可热插 拔
2000
< 300 m
单芯SPF光模块-BIDI
交换机路由光模块参数

目录第1章可插拔模块简介1.1 H3C中端系列以太网交换机支持的可插拔模块类型1.2 光模块概念介绍1.2.1 简介1.2.2 传输速率(Data Rate)1.2.3 传输距离1.2.4 中心波长1.2.5 光纤类型1.2.6 接口连接器类型1.2.7 接口指标1.3 电口模块概念介绍1.3.1 千兆电口模块简介1.3.2 10G电口模块简介第2章 SFP模块2.1 千兆SFP光模块2.1.1 外观图2.1.2 具体型号及规格2.2 百兆SFP光模块2.2.1 外观图2.2.2 具体型号及规格2.3 千兆/百兆BIDI模块2.3.1 外观图2.3.2 具体型号及规格2.4 BIDI GEPON OLT光模块2.4.1 外观图2.4.2 具体型号及规格2.5 千兆CWDM模块2.5.1 外观图2.5.2 具体型号及规格2.6 SFP电口模块2.6.1 外观图2.6.2 具体型号及规格第3章 GBIC模块3.1 GBIC光模块3.1.1 外观图3.1.2 具体型号及规格3.2 GBIC电口模块3.2.1 外观图3.2.2 具体型号及规格第4章 XFP模块4.1 外观图4.2 具体型号及规格第5章 XENPAK模块5.1 XENPAK光模块5.1.1 外观图5.1.2 具体型号及规格5.2 XENPAK LX4光模块5.2.1 外观图5.2.2 具体型号及规格5.3 XENPAK CX4电口模块5.3.1 外观图5.3.2 具体型号及规格第1章可插拔模块简介1.1 H3C中端系列以太网交换机支持的可插拔模块类型H3C中端系列以太网交换机支持的可插拔模块类型如表1-1所示。
表1-1 可插拔模块类型说明:●H3C中端系列以太网交换机的不同产品可支持的可插拔模块类型不同,具体请参见各产品安装手册。
可插拔模块的种类随着时间变化有更新的可能性,所以,若您需要准确的模块种类信息,请咨询H3C公司市场人员或技术支援人员。
新华三集团 刀片和高密度服务器产品手册说明书

Copyright © 2020 新华三集团免责声明:虽然新华三集团试图在本资料中提供准确的信息,但不保证本资料的内容不含有技术性误差或印刷性错误,为此新华三集团对本资料中信息的准确性不承担任何责任。
新华三集团保留在没有任何通知或提示的情况下对本资料的内容进行修改的权利。
CN-081730-20200401-BR-HZ-V1.0新华三集团刀片和高密度服务器产品手册新华三集团杭州总部杭州市滨江区长河路466号邮编:310052北京总部北京市朝阳区广顺南大街8号院 利星行中心1号楼邮编:10010272H3C UniServer 边缘计算服务器02服务器产品全家福04H3C UniServer 刀片服务器20HPE 刀片服务器28HPE 塑合型服务器 40HPE 高密度服务器55HPE 边缘计算服务器64HPE Moonshot服务器目录CONTENTSH3C UniServer刀片服务器服务器产品全家福H3C UniServer B7800 G3H3C UniServer B5600 G3H3C UniServer B5800 G3HPE 刀片服务器HPE ProLiant BL460c Gen10HPE BladeSystem c7000HPE 塑合型服务器HPE Synergy 660 Gen10 HPE Synergy D3940HPE Synergy 480 Gen10HPE Synergy 12000HPE 高密度服务器HPE Apollo 6000 Gen10HPE Apollo 6500 Gen10HPE Apollo 2000 Gen10HPE Apollo 70HPE 边缘计算服务器HPE Moonshot服务器HPE Edgeline EL1000HPE Edgeline EL300HPE Edgeline EL4000HPE Edgeline EL8000HPE MoonshotH3C UniServer B5700 G3H3C UniServer B10000H3C UniServer B16000H3C UniServer边缘计算服务器H3C UniServer E3200 G332 HPE Synergy 480 Gen10 计算模块35 HPE Synergy 660 Gen10 计算模块38 HPE Synergy D3940 硬盘笼H PE 高密度服务器41 HPE Apollo 70 系统43 HPE Apollo 2000 Gen10 系统48 HPE Apollo 6000 Gen10 系统52 HPE Apollo 6500 Gen10 系统H PE 边缘计算服务器56 HPE Edgeline EL300 系统58 HPE Edgeline EL1000系统60 HPE Edgeline EL4000 系统62 HPE Edgeline EL8000 系统H PE Moonshot服务器65 HPE Moonshot服务器H3C UniServer边缘计算服务器73 H3C UniServer E3200 G3 服务器服务器产品全家福03 服务器产品全家福H3C UniServer刀片服务器05 H3C UniServer B16000 塑合智能刀片服务器07 H3C UniServer B5700 G3 刀片服务器09 H3C UniServer B5800 G3 刀片服务器11 H3C UniServer B7800 G3 刀片服务器13 H3C UniServer B10000 机箱17 H3C UniServer B5600 G3 服务器H PE 刀片服务器21 HPE BladeSystem c7000 机箱25 HPE ProLiant BL460c Gen10刀片服务器HPE 塑合型服务器29 HPE Synergy 12000 机箱H3C UniServer B16000塑合智能刀片服务器,适合应用在动态需求更多的数据中心,可以支持多达16台刀片服务器和存储设备。
H3C SR6600路由器 接口模块手册

资料获取方式
您可以通过H3C网站()获取最新的产品资料: H3C 网站与产品资料相关的主要栏目介绍如下: z [服务支持/文档中心]:可以获取硬件安装类、软件升级类、配置类或维护类等产品资料。 z [产品技术]:可以获取产品介绍和技术介绍的文档,包括产品相关介绍、技术介绍、技术白皮
前言
本书介绍了 H3C SR6600 路由器支持的模块(如 HIM、MIM 和 SAP)的型号、面板外观、指示灯、 接口属性以及连接接口电缆的方法。同时还介绍了各种模块、主控单元以及灵活接口平台之间的适 配关系。 前言部分包含如下内容: z 读者对象 z 本书约定 z 产品配套资料 z 资料获取方式 z 技术支持 z 资料意见反馈
大类 业务配置
资料名称 安装视频 配置指导 命令参考 典型配置举例
版本说明书
内容介绍
帮助您掌握 LSTM1PEMC 和 LSTM1PEM2N 两种交流电源的安装方法 帮助您掌握设备软件功能的配置方法及配置步骤
详细介绍设备的命令,相当于命令字典,方便您查阅各个命令的功能
帮助您了解产品的典型应用和推荐配置,从组网需求、组网图、配置步 骤几方面进行介绍
通信技术有限公司的商标。对于本手册中出现的其它公司的商标、产品标识及商品名称,原因,本手册内容有可能变更。H3C 保留在没有任何通知或者提示的情况 下对本手册的内容进行修改的权利。本手册仅作为使用指导,H3C 尽全力在本手册中提供准确的信 息,但是 H3C 并不确保手册内容完全没有错误,本手册中的所有陈述、信息和建议也不构成任何 明示或暗示的担保。
4.图标约定 本书使用的图标及其含义如下:
华三集团网络产品手册无线版说明书

新华三集团杭州总部杭州市滨江区长河路466号邮编:Copyright © 2020新华三集团 保留一切权利CN-201030-20200508-BR-SD-V1.0免责声明:虽然新华三集团试图在本资料中提供准确的信息,但不保证本资料的内容不含有技术性误差或印刷性错误,为此新华三集团对本资料中信息的准确性不承担任何责任。
新华三集团保留在没有任何通知或提示的情况下对本资料的内容进行修改的权利。
新华三网络产品手册无线物联网H3C iBox580 G2物联网业务一体机H3C IG530物联网业务网关/业务板H3C IG4100-L室内型LoRa网关H3C IG4300-L-R室外型LoRa网关H3C IG4500-L基站型LoRa网关H3C IG4510-L基站型LoRa网关H3C IG4520-L基站型LoRa网关H3C IN4500-L物联网终端设备H3C T320系列室内型物联网网关/接入单元H3C T320系列工业级物联网接入单元H3C T300系列室内型物联网接入单元H3C T300系列室外型物联网接入单元 H3C WA5320X-L室外全融合物联网关0205081013151720222730333501WLANH3C WX5500H系列新一代企业级核心多业务无线控制器H3C WX3500H系列新一代企业级核心多业务无线控制器H3C WX2500H系列新一代企业级核心多业务无线控制器H3C WX2508H-PWR-LTE新一代企业级多业务无线控制器H3C WX1804H-PWR 新一代企业级多业务无线控制器H3C 新一代全系列无线控制业务插卡H3C WBC560多业务无线控制器H3C WBC580新一代多业务无线控制器H3C WA6600系列802.11ax无线接入设备6172 8393104114125137148H3CWA6500、6300系列802.11ax无线接入H3C WA5500系列802.11ac无线接入设备H3C WA5300系列802.11ac无线接入设备H3C UAP系列802.11ac无线接入设备H3C终结者系列无线接入设备H3C WA6600X系列室外802.11ax无线接入设备 H3C WA5600X系列室外802.11ac无线接入设备17 H3C WA5300X系列室外802.11ac无线接入设备17221423227429236837938460移动通信核心网系列H3C EPC3108演进型分组核心网H3C vEPC3200虚拟化演进型分组核心网基站系列H3C BBU3100分布式基带单元H3C BBU3120分布式基带单元H3C RRU3184分布式基带单元边缘分流网关H3C vMEGW3200移动边缘分流网关终端系列H3C CPE3200-18室外型用户终端设备4345 485053 55 5742智联接 绘未来G2物联网业务一体机是新华三技术有限公司(H3C)自主研发的集成物联网设备管理及业务应用的融合式设备。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
1 可插拔模块简介1.1 H3C高端网络产品支持的可插拔模块类型H3C高端网络产品支持的可插拔模块类型如表1-1所示。
H3C高端网络产品包括H3C S9500E系列路由交换机、H3C S12500系列路由交换机、H3C SR8800系列路由器和H3C CR16000系列路由器。
表1-1 可插拔模块类型
H3C高端网络产品的不同产品可支持的可插拔模块类型不同,具体请参见各产品安装手册。
∙
可插拔模块的种类随着时间变化有更新的可能性,所以,若您需要准确的模块种类信息,请咨询H3C公司市场人∙
员或技术支援人员。
1.2 光模块概念介绍
1.2.1 简介
光模块用于光信号的传输,传输媒质为光纤。
光纤传输方式损耗低,传输距离远,在长距离传输方面具有很强的优势。
H3C高端网络产品支持多款不同规格的光模块,用户可以根据自己的需要选择合适的光模块,通过光纤进行数据传输。
目前常规通用的光模块主要包括:光发送器,光接收器,Transceiver(光收发一体模块)以及Transponder(光转发器)。
H3C高端网络产品主要支持Transceiver和Transponder两种光模块。
1. Transceiver(光收发一体模块)
Transceiver的主要功能是实现光电/电光变换,包括光功率控制、调制发送,信号探测、IV转换以及限幅放大判决再生功能,此外还有防伪信息查询、TX-disable等功能,常见的有:SIP9、SFF、SFP、GBIC、XFP等。
2. Transponder(光转发器)
Transponder除了具有光电变换功能外,还集成了很多的信号处理功能,如:MUX/DEMUX、CDR、功能控制、性能量采集及监控等功能。
1.2.2 传输速率(Data Rate)
传输速率指每秒传输比特数,单位Mb/s或Gb/s。
H3C高端网络产品所支持光模块主要提供以下六种级别的传输速率:100M、155M、622M、1000M、2.5G和10G。
1.2.3 传输距离
光模块的传输距离分为短距、中距和长距三种。
一般认为2km及以下的为短距离,10~20km的为中距离,30km、40km 及以上的为长距离。
光模块的传输距离受到限制,主要是因为光信号在光纤中传输时会有一定的损耗和色散。
损耗是光在光纤中传输时,由于介质的吸收散射以及泄漏导致的光能量损失,这部分能量随着传输距离∙
的增加以一定的比率耗散。
色散的产生主要是因为不同波长的电磁波在同一介质中传播时速度不等,从而造成光信号的不同波长成∙
分由于传输距离的累积而在不同的时间到达接收端,导致脉冲展宽,进而无法分辨信号值。
因此,用户需要根据自己的实际组网情况选择合适的光模块,以满足不同的传输距离要求。
1.2.4 中心波长
中心波长指光信号传输所使用的光波段。
目前常用的光模块的中心波长主要有三种:850nm波段、1310nm波段以及1550nm 波段。
850nm波段:多用于短距离传输
∙
1310nm和1550nm波段:多用于中长距离传输
∙
1.2.5 光纤类型
1. 光纤模式(Fiber Mode)
按光在光纤中的传输模式可将光纤分为单模光纤和多模光纤两种。
MMF(Multi Mode Fiber,多模光纤),纤芯较粗,可传多种模式的光。
但其模间色散较大,且随传输∙
距离的增加模间色散情况会逐渐加重。
多模光纤的传输距离还与其传输速率、芯径、模式带宽有关,具体关系请参见表1-2。
表1-2 多模光纤规格表
1.2.6 接口连接器类型
接口连接器用于连接可插拔模块及相应的传输媒质。
H3C高端网络产品支持的光模块所采用的光纤连接器有两种:SC连接器和LC连接器。
1. SC连接器
SC(Subscriber Connector Standard Connector,标准光纤连接器),外观图如图1-1所示。
图1-1 SC连接器外观图
2. LC连接器
LC(Lucent Connector or Local Connector,朗讯连接器),外观图如图1-2所示。
图1-2 LC连接器外观图
为了保护光纤连接器的清洁,请务必保证在未连接光纤时盖上防尘帽。
1.2.7 接口指标
1. 输出光功率
输出光功率指光模块发送端光源的输出光功率,单位:dBm。
2. 受压灵敏度
受压灵敏度指输入信号在附加了抖动和垂直眼闭(vertical eye closure)劣化条件后测得的灵敏度值,单位:dBm。
3. 光饱和度
又称接收过载光功率,指的是在一定的传输速率下,维持一定的误码率(10-10~10-12)时的最大输入光功率,单位:dBm。
需要注意的是,光探测器在强光照射下会出现光电流饱和现象,当出现此现象后,探测器需要一定的时间恢复,此时接收灵敏度下降,接收到的信号有可能出现误判而造成误码现象,而且还非常容易损坏接收端探测器,在使用操作中应尽量避免超出其饱和光功率。
对于长距光模块,由于其平均输出光功率一般大于其最大输入光功率(即光饱和度),因此请用户使用时关注光纤使用长度,以保证到达光模块的实际接收光功率小于其光饱和度,否则有可能造成光模块的损坏。
本手册中所有光模块的最小输入光功率对应光模块的受压灵敏度,最大输入光功率对应光模块的光饱和度(接受过载光功率)。
1.3 电口模块概念介绍
1.3.1 千兆电口模块简介
H3C高端网络产品支持SFP电口模块:SFP-GE-T。
千兆电口模块所采用的传输媒质为5类非屏蔽双绞线,相比光纤传输方式来说,双绞线传输的传输距离较短,只适用于小范围组网环境。
1. 传输距离
电信号在双绞线中的传输距离最长为100m,主要原因是因为电信号在双绞线中传输时存在衰减现象。
衰减(attenuation)是指经过一段时间或者距离后信号减弱。
出现衰减的原因是:线缆本身对传输有一定的阻力,从而导致电信号沿线缆传输时逐渐减弱。
若传输距离很长的话,信号强度会降得很低,致使信噪比降至可接受标准以下,无法正确分辨信号与噪声而产生误判。
因此,只有在传输距离较短的情况下才可以选择电口模块。
2. 接口连接器类型
H3C高端系列以太网交换机支持的两款千兆电口模块采用的连接器为RJ-45(Registered Jack,注册Jack)双绞线连接器。
外观图如图1-3所示。
图1-3 RJ-45连接器外观图
表1-3 RJ-45 GE接口引脚分配
2 SFP模块
2.1 1000M SFP光模块2.1.1 外观图
图2-1 千兆/百兆SFP光模块外观示意图
2.1.2 具体型号及规格
表2-1 1000M SFP光模块属性
2.2 100M SFP光模块2.2.1 外观图
2.2.2 具体型号及规格
表2-2 100M SFP光模块属性
2.3 155M SFP光模块2.
3.1 外观图
表2-3 155M SFP光模块属性
2.4 622M SFP光模块2.4.1 外观图
2.4.2 具体型号及规格
表2-4 622M SFP光模块属性
2.5 2.5G SFP光模块2.5.1 外观图
表2-5 2.5G SFP光模块属性
2.6 155M/1000M BIDI模块2.6.1 外观图
图2-2 155M/1000M BIDI模块外观示意图
2.6.2 具体型号及规格
表2-6 155M/1000M BIDI模块属性
∙BIDI 模块发送和接收两个方向使用不同的中心波长,从而实现光信号在同一根光纤内的双向传输。
∙BIDI 模块必须成对使用,例如:一端使用了SFP-GE-LX-SM1310-BIDI ,另外一端就必须使用
SFP-GE-LX-SM1490-BIDI 。
2.7 1000M CWDM 模块
2.7.1 外观图
图2-3 1000M CWDM 模块外观示意图
2.7.2 具体型号及规格
表2-7 1000M CWDM 模块属性
千兆CWDM模块采用CWDM技术,可以通过外接波分复用器,将不同波长的光信号复合在一起,通过一根光纤进行传输,从而节约光纤资源。
同时,接收端需要使用波分解复用器对复合光信号进行分解。
2.8 SFP电口模块
2.8.1 外观图
图2-4 SFP电口模块外观示意图
2.8.2 具体型号及规格
表2-8 SFP电口模块属性
3 SFP+模块
3.1 SFP+光模块
3.1.1 外观图
3.1.2 具体型号及规格
表3-1 SFP+光模块属性
3.2 SFP+电缆
3.2.1 外观图
图3-1 SFP+电缆外观示意图
3.2.2 具体型号及规格
表3-2 SFP+电缆属性
4 XFP模块4.1 外观图
图4-1 XFP模块外观示意图
4.2 具体型号及规格表4-1 XFP模块属性。