IBM_X系列服务器操作手册v1.0

IBM X系列服务器 操作手册 Ver. 1.0 目 录 规范及流程篇 ............................................................................................................... 3 服务器技术篇 ............................................................................................................... 3 一、X系列服务器简介 ............................................................................................ 3 二、IBM阵列卡 ....................................................................................................... 4 1、分类................................................................................................................... 4 2、配置RAID(以ServeRAID 8i为例) .......................................................... 6 三、收集日志 ............................................................................................................ 9 1、DSA日志 .......................................................................................................... 9 2.RAID日志 ......................................................................................................... 12 3、BMC日志 ....................................................................................................... 18 四、故障排除 .......................................................................................................... 24 1.故障排除步骤及技巧........................................................................................ 24 2、DASD故障 ..................................................................................................... 26 五、必备工具 .......................................................................................................... 28 规范及流程篇 服务器技术篇 一、X系列服务器简介 众所周知,IBM的服务器产品线非常丰富齐全,从入门级到大型机,一应俱全。打开IBM的官方网站,IBM给我们带来的第一印象就是——拥有如此多的专业产品可供选择。总体来看,IBM服务器家族目前共有4条产品线:基于 Intel 架构的服务器 x系列(xSeries,近日IBM已经升级推出基于AMD皓龙处理器的5款新品)、中型企业级服务器i系列(iSeries)、UNIX 服务器p系列 (pSeries)和大型主机z系列(zSeries)。这四大系列基本都包括了从入门级到企业级的各种档次的服务器产品,在结构上也全面包括了塔式、机架式、刀片和机柜式。 IBM eServer xSeries系列服务器是IBM服务器品牌之一。eServer xSeries服务器得名于IBM工业标准服务器经典的“X-架构”,是eServer家族中支持开放工业标准的代表,它是由原来的Netfinity系列发展而来的。下面我们将用一组数据为标题,来简要描述IBM x系列的发展历程: 1)9年历史 IBM在1998年提出X系列服务器设想,到现在已经有9年历史。而使x系列真正意义上进入到应用领域,还是到了2001年之后。相比较IBM大型机的诞生时间,x系列所关注的目标是面向中小企业,因此要比面向金融行业的大型机稍晚一些。 2)2亿美元 从x1 系列到x3共经历了5载历程,耗资近2亿美元。正是IBM看到中小企业蕴含着无限商机,因此不惜重金打造x系列。 3)3代架构 IBM x系列共经历了3次架构变革。早在2001年,IBM大型机事业部就历时三年、耗资2000多万美元开发出“SUMMIT”芯片组。第一代X-架构的诞生,使得IBM芯片组为INTEL处理器赋予更强能力,工业标准服务器开始进入企业关键应用领域;以HURRICANE芯片组为核心的X3架构同样历时三年,耗资高达1亿美元。据分析数据显示,X3架构相比X2,其系统性能约有38%的提升。 4)4地研发 IBM在全球斥资成立4座xSeries研发中心。最近的一次是在2004年7月,IBM成立了“xSeries台湾研发中心” ,研发中心初期人员达到80人,该中心定位为Mission Lab,赋予其“end-to-end开发”使命,亦即从市场需求汇集、规格订定、乃至于产品的最终出货等所有流程。目前已经研发出包括x206、x306及x226等3款服务器,相关投资金额业已累积达数千万美元。另外3座研发中心位于美国的Raleigh、Austin与 Kirkland。 5)数年发布 梳理IBM历年的新品发布轨迹,我们发现IBM对于1、2路服务器新品推出的力度在逐年加大,无论从推出频率还是新品数量来看,都使IBM x系列产品线日趋成熟,造就了今日非比寻常的产品线。 2002年,IBM 公司推出x232 系列服务器的升级产品——x235,针对用户不断增长的商业需要而设计;同年8月,IBM推出x 200的升级产品——面向小型企业的Pentium 4 单路服务器x205,具有热插拔硬盘功能,更加易于使用及安装。 2003年2月,IBM宣布推出当时全球最快的4路机架优化式服务器x365和最薄的4路刀片服务器BladeCenter HS40;同年8月率先推出了基于AMD处理器的面向高性能运算的系统。 2004年,IBM再次推出x205换代产品——x206塔式服务器和新一代机架优化式服务器x306;同年9月,IBM在中国市场推出了8款基于英特尔新至强(Nocona) 64位扩展技术处理器的服务器新产品。这是IBM eServer x系列品牌诞生以来规模最大的一次产品线更新,此次发布的新产品包括x206、x226、x236、x306、x336、x346以及IBM eServer BladeCenter刀片服务器。 2005年,IBM x 系列服务器在技术上不断创新,推出了X3 架构系列产品,为基于下一代 64 位 Intel 至强处理器 7000 序列的 x 系列服务器,即入门级服务器x100 、x206m 、 x306m 产品系列。 2006年5月,IBM正式发布了4款基于Intel全新Dempsey芯片的双核服务器。8月份,IBM宣布扩展其基于AMD Opteron处理器的服务器产品线,推出5款新品——BladeCenter LS41、BladeCenter LS21、System x3755、System x3655和System x3455。 6)一朝更名 2006年5月, IBM宣布IBM eServer xSeries改名为IBM System x,后面的型号也全面更新,如原来的高性能服务器x260更名为x3800、x366更名为x3850、x460更名为x3950,其中x3代表这些系统是基于X3架构,倒数第三个数字代表功能,数字越大功能越强;倒数第二个数字代表塔式(0)还是机架式(5);最后一个数字代表采用Intel(0)或AMD(5)的处理器。 综观IBM eServer的Z、I、P与X这4个系列服务器产品线,x系列相对起步较晚,但xSeries 成长率最近几年尤为显著。

二、IBM阵列卡 1、分类 目前IBM的阵列卡从控制的硬盘来说可以分成三大类: 1.控制SCSI硬盘的SCSI RAID控制器: ServeRaid 、ServeRaid II、ServeRaid 3L、ServeRaid 3H、ServeRaid 4L、ServeRaid 4Lx、ServeRaid 4M、ServeRaid 4Mx、ServeRaid 4H、ServeRaid 5i、ServeRaid 6M、ServeRaid 6i/6i+、ServeRaid 7e、ServeRaid 7k ;

2.控制SATA硬盘的SATA RAID控制器: ServeRaid 7e 、ServeRaid 7t;

3.控制SAS硬盘以及热插拔SATA硬盘的SAS RAID控制器:

合集下载

x3850 X5产品手册

x3850 X5产品手册

IBM成长型企业解决方案System xIBM System x3850 X5 智能新一代,英特尔至强处理器7500 最大限度地增加内存、降低成本和简化部署要点●无与伦比的灵活性、可满足不断变化的工作负载需求●优化的系统、具有可针对目标工作负载进行自定义的配置●以更低的总成本实现更高的性能和利用率●借助来源于大型机的可靠性使工作负载保持正常运行●借助节能智能型设计和远程访问,实现可轻松拥有的、简化的电源和系统管理借助x3850 X5最大限度地增加内存、降低成本和简化部署根据您的工作负载需求量身定制随着成本、工作负载以及对全天候可用性的需求不断增长,您的组织已经不能再容忍利用率不高或不可靠的服务器。

IBM System x3850 X5构建在下一代企业I B M®X架构®技术和英特尔®至强®处理器之上。

可在节能、省钱的设计中提供卓越的性能和无与伦比的可靠性。

它最大的优点是能够提供超凡的灵活性,帮助您在正确的时间获得正确的功能。

随需扩展x3850 X5服务器允许您自由选择极其灵活的配置以及内存扩展和节点分区功能。

模块化的构造块设计使您既能够按照当前需求自定义系统;同时又能够应对不断变化的工作负载。

x3850 X5拥有4个插槽,64个D I MM,可扩展为4个插槽和96个D I MM,而最高可达8个插槽和192个D I MM。

可根据环境的变化重新分配资源和分区系统。

x3850 X5能够满足您的当前需求,同时提供一种简便、经济有效的升级途径,可在您做好准备时更改您的环境。

登录社区,观看相关视频(goo.gl/qeorI)提高投资回报八核处理器和扩展的内存容量使内存密集型应用程序能够实现更高的利用率、吞吐量和带宽。

将32台完全机架的旧式4U服务器整合到一台行业领先的I B M X架构e X5系统,大大降低总成本。

每台服务器可提供更多、更强大的虚拟服务器,而且许可成本也更低。

MIG-630系列切换台使用说明书-V1.0

MIG-630系列切换台使用说明书-V1.0
关亍软件
丌得对本产品上安装癿软件迚行更改、反编译、反汇编、解密戒者迚行反向工程, 以上行为均属远法。
特性
同时支持 10 路信号输入(可扩展为 12 路); 支持 3 组图像输出(DVI+VGA)接口,包括一路主输出和 2 路预监; 支持 1 路 Logo 输入和 1 路黑背景输入; 支持多种切换效果,瞬间切换,淡入淡出,划像,边沿溶解,切换时间可调; 支持图文叠加、抠图合成功能,方便实现字幕叠加、图像合成效果; 内部多图层处理,最多支持 3 画面同时输出; 支持多路模板癿存储和调用;
5
功能介绍
概述
MIG-630 系列产品是针对显示系统开収癿视频切换台,采用了业内顶尖癿图像 处理芯片,内部 12 位数字处理,图像更清晰,色彩更丰富。
先迚癿隔行运动图像自适应处理技术,消除视频图像运动拖尾和锯齿现象,对亍 普通癿 PAL/NTSC 视频,输出图像更加清晰细腻,对亍高清癿 1080i 信号,输 出癿图像细节丰富,色彩饱满,图像质量处亍业界领先水平。
掉。 当您要加入硬件设备到本产品中戒者要去除本产品中癿硬件设备时,请确认所有
癿信号线和电源线已事先拔掉。 在迚行任何硬件操作之前,请事先关闭切换台电源,并通过触摸接地表面来释放
您身上癿静电。 请在干净、干燥、通风癿环境中使用,丌要将本产品放入高温、潮湿等环境中使
用。 本产品为电子类产品,请进离火源、水源以及易燃、易爆癿危险品。 本产品内有高压部件,请丌要打开机箱戒者自行对本设备迚行维修。 如収现有冎烟、异味等异常情况,请立刻关掉电源开关,并不经销商联系。
全高清数模混合视频切换台
使用说明书 △! 使用视频切换台之前,请先仔细阅读此使用说
明书并将之妥善保存以备日后参考。

IBM System x3400 M3 产品指南(撤回产品)说明书

IBM System x3400 M3 产品指南(撤回产品)说明书

IBM System x3400 M3 (Withdrawn)Product Guide (withdrawn product)The System x3400 M3 servers are self-contained, high-performance, 5U tower systems designed for web and business server applications in remote or distributed environments. These servers are highly scalable in configuration, performance, and availability. They offer two-way SMP power with the latest Intel Xeon 5600 series processors, a dual connector 8-port SAS/SATA RAID controller on hot-swap models, an embedded Gigabit Ethernet controller, and six PCI Express 2.0 slots. These servers support SATA or SAS HDDs.These servers are flexible tower models that deliver the best blend of power, manageability, expandability, and serviceability. They meet the requirements of server applications in the small-to-medium businesses that need an affordable general-purpose network server. These servers fit into business environments where tower configurations are required. Figure 1 shows the IBM® System x3400 M3.Figure 1. The IBM System x3400 M3Did you know?The System x3400 M3 server supports optional spare DIMMs, memory mirroring, and RAID-0, RAID-1, and RAID-1E support standard with optional RAID-5, RAID-6, RAID-10, and RAID-50 available. It features large amounts of internal expansion and I/O support. Comprehensive systems management tools such as advanced diagnostics, Predictive Failure Analysis, and the ability to control resources from a single point make it easy to deploy, integrate, service, and manage from any location.Click here to check for updatesFigure 2. Front view of the IBM System x3400 M3Figure 3. Rear view of the IBM System x3400 M3Figure 4 shows the locations of key components inside the server.Figure 4. Inside view of the IBM System x3400 M3 Standard specificationsThe following table lists the standard specifications. Table 1. Standard specificationsStandard modelsThe following table lists the standard models. Table 2. Standard modelsModel†Intel Processor*(2 maximum)RAM DiskcontrollerDisk bays(std/max)Disks Network Optical PowersupplyModels announced February 20117378/ 7379-A2x 1x E5603 4C 1.60GHz4 MB 1066 MHz1x 2GBIntegratedSATA(no RAID)4x 3.5"SS / 4Open 2 x GbE DVD1x 670 WFixed7378/ 7379-A4x 1x E5603 4C 1.60GHz4 MB 1066 MHz1x 2GBServeRAIDBR10il v24x 3.5"HS / 4Open 2 x GbE DVD1x 670 WFixed7378/ 7379-B2x 1x E5606 4C 2.13GHz8 MB 1066 MHz1x 2GBIntegratedSATA(no RAID)4x 3.5"SS / 4Open 2 x GbE DVD1x 670 WFixed7378/ 7379-B4x 1x E5606 4C 2.13GHz8 MB 1066 MHz1x 2GBServeRAIDBR10il v24x 3.5"HS / 4Open 2 x GbE DVD1x 670 WFixed7378/ 7379-C2x 1x E5607 4C 2.26GHz8 MB 1066 MHz1x 2GBServeRAIDBR10il v24x 3.5"HS / 4Open 2 x GbE DVD1x 670 WFixed7378/ 7379-56x 1x E5620 4C 2.40GHz12 MB 1066 MHz1x 4GBServeRAIDBR10il v24x 3.5"HS / 4Open 2 x GbE DVD1x 670 WFixed7378/ 7379-58x 1x E5620 4C 2.40GHz12 MB 1066 MHz1x 4GBServeRAIDM10158x 2.5"HS / 16Open 2 x GbE DVD 1 x 920 WHot-swap7378/ 7379-D2x 1x E5645 6C 2.40GHz12 MB 1333 MHz1x 4GBServeRAIDM10158x 2.5"HS / 8Open 2 x GbE DVD1x 670 WFixed7378/ 7379-F2x 1x E5649 6C 2.53GHz12 MB 1333 MHz1x 4GBServeRAIDM501416x 2.5"HS / 16Open 2 x GbE DVD 1 x 920 WHot-swap† The x3400 M3 is available as machine type 7378 with a 1-year warranty (AP only) or as machine type 7379 with a 3-year warranty. This is the only difference between systems of the same model (for example, comparing 7378-A2x and 7379-A2x).* In the processor column: Standard quantity of processors, processor model, core speed, cores, L3 cache, memory speed.Refer to the Standard Specifications section for information about standard features of the server.Express modelsThe following table lists the region-specific Express models. Express models are preconfigured with additional components, such as processors and memory, to make the ordering and installation process simpler.Table 3. Express modelsRegion/ model Processor* (2maximum)Memory RAIDcontrollerDiskbays(std /max)Disks Network Optical PowersupplyNA and LA7379-E1U 1x Xeon E5503 2.0GHz 2C 4 MB 800MHz3x 2 GB BR10il v24x 3.5"SS / 4Optional2x GbE DVD-ROM1x 670W7379-E2U 1x Xeon E5506 2.13GHz 4C 4 MB 800MHz3x 4 GB BR10il v24x 3.5"HS / 4Optional2x GbE DVD-ROM1x 670W7379-E3U 1x Xeon E5620 2.40GHz 4C 12 MB 1066MHz3x 4 GB M10158x 2.5"HS / 16Optional2x GbE DVD-ROM1x 920WNE and SW IOT7379-K1G 1x Xeon E5503 2.0GHz 2C 4 MB 800MHz1x 2 GB BR10il v24x 3.5"SS / 4Optional2x GbE DVD-ROM1x 920W7379-K2G 1x Xeon E5506 2.13GHz 4C 4 MB 800MHz1x 4 GB M10154x 3.5"HS / 8Optional2x GbE Multiburner1x 920W7379-K3G 1x Xeon E5507 2.26GHz 4C 4 MB 800MHz1x 4 GB M1015 +AdvanceFeatureKey8x 2.5"HS / 16Optional2x GbE Multiburner1x 920W7379-K4G 1x Xeon E5620 2.40GHz 4C 12 MB 1066MHz1x 4 GB M1015 +AdvanceFeatureKey8x 2.5"HS / 16Optional2x GbE Multiburner2x 920W7379-K8G 1x Xeon E5506 2.13GHz 4C 4 MB 800MHz1x 4 GB M50144x 3.5"HS / 8Optional2x GbE Multiburner2x 920W7379-KDG 1x Xeon E5620 2.40GHz 4C 12 MB 1066MHz1x 4 GB M50148x 2.5"HS / 162x 146 GB2x GbE Multiburner1x 920W7379KXG1x Xeon E5607 2.26GHz 4C 8 MB 1333MHz 1x 4 GB M10158x 2.5"HS / 8Optional2x GbE Multiburner1x 670W7379KZG1x Xeon E5620 2.4GHz 4C 12 MB 1333MHz 1x 2 GB M50146x 2.5"HS / 8Optional2x GbE Multiburner1x 670WCEE and MEA IOT7379-K5G 1x Xeon E5506 2.13GHz 4C 4 MB 800MHz2x 4 GB M10154x 3.5"HS / 8Optional2x GbE Multiburner1x 920W7379-K6G 1x Xeon E5506 2.13GHz 4C 4 MB 800MHz1x 4 GB M50148x 2.5"HS / 162x 146 GB2x GbE Multiburner2x 920W7379-K8G 1x Xeon E5506 2.13GHz 4C 4 MB 800MHz1x 4 GB M50144x 3.5"HS / 8Optional2x GbE Multiburner2x 920W7379-KDG 1x Xeon E5620 2.40GHz 4C 12 MB 1066MHz1x 4 GB M50148x 2.5"HS / 162x 146 GB2x GbE Multiburner1x 920W7379-KBG 1x Xeon E5620 2.40GHz 4C 12 MB 1066MHz1x 4 GB M50144x 3.5"HS / 8Optional2x GbE Multiburner1x 920WRCIS7379-K9G 1x Xeon E5506 2.13GHz 4C 4 MB 800MHz1x 4 GB M50144x 3.5"HS / 8Optional2x GbE Multiburner1x 920W7379-KAG 1x Xeon E5506 2.13GHz 4C 4 MB 800MHz1x 4 GB M5014 +Battery4x 3.5"HS / 8Optional2x GbE Multiburner1x 920W7379-KBG 1x Xeon E5620 2.40GHz 4C 12 MB 1066MHz1x 4 GB M50144x 3.5"HS / 8Optional2x GbE Multiburner1x 920W7379-KCG 1x Xeon E5620 2.40GHz 4C 12 MB 1066MHz2x 4 GB M5015 +Battery8x 2.5"HS / 16Optional2x GbE Multiburner1x 920WJapan7379-PAM 1x Xeon E5503 2.0GHz 2C 4 MB 800MHz2x 2 GB BR10il v24x 3.5"HS / 82x 1 TB2x GbE DVD-ROM1x 920W7379-PAN 1x Xeon E5506 2.13GHz 4C 4 MB 800MHz2x 2 GB M5014 +Battery4x 3.5"HS / 83x 300 GB2x GbE DVD-ROM1x 920WChina7379-I011x Xeon E5506 2.13GHz 4C 4 MB 800MHz 1x 4 GB M10158x 2.5"HS / 81x 146 GB2x GbE DVD-ROM1x 670W7379-I051x Xeon E5506 2.13GHz 4C 4 MB 800MHz 1x 4 GB M5015 (nobattery)8x 2.5"HS / 81x 146 GB2x GbE DVD-ROM1x 670W7379-I211x Xeon E5620 2.40GHz 4C 12 MB 1066MHz 1x 4 GB M10158x 2.5"HS / 81x 146 GB2x GbE DVD-ROM1x 670W7379-I251x Xeon E5620 2.40GHz 4C 12 MB 1066MHz 1x 4 GB M5015 (nobattery)8x 2.5"HS / 81x 146 GB2x GbE DVD-ROM1x 670WISA7379-I4S1x Xeon E5506 2.13GHz 4C 4 MB 800MHz 1x 2 GB BR10i4x 3.5"SS / 41x 250 GB2x GbE DVD-ROM1x 670W7379-I3S1x Xeon E5507 2.26GHz 4C 4 MB 800MHz 1x 4 GB BR10i8x 2.5"HS / 161x 146 GB2x GbE DVD-ROM2x 920WHong Kong7379-I5H1x Xeon E5506 2.13GHz 4C 4 MB 800MHz 2x 2 GB M50144x 3.5"HS / 4Optional2x GbE DVD-ROM1x 670W* In the processor column: standard quantity of processors, processor model, core speed, cores, L3 cache, memory speed.Processor optionsThe server supports the processor options listed in the following table. The server supports up to two processors. The table also shows which server models have each processor standard. If there is no corresponding where-used model for a particular processor, then this processor is only available through CTO.Table 4. Processor optionsFeature code**Description Standard modelswhere usedIntel Xeon 5600 series processorsA0VC / A0VD Intel Xeon Processor E5603 4C 1.60GHz 4 MB Cache 1066MHz 80w A2x, A4xA0VE / A0VF Intel Xeon Processor E5606 4C 2.13GHz 8 MB Cache 1066MHz 80w B2x, B4xA0VG / A0VH Intel Xeon Processor E5607 4C 2.26GHz 8 MB Cache 1066MHz 80w C2x4493 / 4631Intel Xeon Processor E5620 4C 2.40GHz 12 MB Cache 1066MHz 80w52x, 54x, 56x, 58x 4494 / 4632Intel Xeon Processor E5630 4C 2.53GHz 12 MB Cache 1066MHz 80w62x4495 / 4633Intel Xeon Processor E5640 4C 2.66GHz 12 MB Cache 1066MHz 80w72x, 74xA0VJ / A0VK Intel Xeon Processor E5645 6C 2.40GHz 12 MB Cache 1333MHz 80w D2xA0VL / A0VM Intel Xeon Processor E5649 6C 2.53GHz 12 MB Cache 1333MHz 80w F2x0723 / 7683Intel Xeon Processor L5609 4C 1.86GHz 12 MB Cache 1066MHz 40w-0722 / 7682Intel Xeon Processor L5630 4C 2.13GHz 12 MB Cache 1066MHz 40w-0721 / 7681Intel Xeon Processor L5640 6C 2.26GHz 12 MB Cache 1333MHz 60w-4496 / 4634Intel Xeon Processor X5650 6C 2.66GHz 12 MB Cache 1333MHz 95w-4497 / 4635Intel Xeon Processor X5660 6C 2.80GHz 12 MB Cache 1333MHz 95w-4498 / 4636Intel Xeon Processor X5670 6C 2.93GHz 12 MB Cache 1333MHz 95w-A0VS / A0VT Intel Xeon Processor X5675 6C 3.06GHz 12 MB Cache 1333MHz 95w-Intel Xeon 5500 series processors0705 / 4639*Intel Xeon Processor E5503 2C 2.0 GHz 4 MB Cache 800 MHz 80w22x, 24x6656 / 6955Intel Xeon Processor E5504 4C 2.00 GHz 4 MB Cache 800MHz 80w-4428 / 4427Intel Xeon Processor E5506 4C 2.13 GHz 4 MB Cache 800MHz 80w32x, 34x0706 / 4640*Intel Xeon Processor E5507 4C 2.26 GHz 4 MB Cache 800MHz 80w42x4425 / 4424Intel Xeon Processor E5540 4C 2.53 GHz 8 MB Cache 1066MHz 80w-** The first feature code is for Processor 1. The second feature code is for Processor 2.* Withdrawn from marketing.Memory optionsFigure 5. Internal drive configurationsPart number FeaturecodeDescription Maximumsupported*3.5" Simple-Swap SATA and NL SATA HDDs81Y9778A280IBM 3TB 7.2K 6Gbps NL SATA 3.5" SS HDD4 42D07875416IBM 2 TB 7200 NL SATA 3.5" SS HDD4 39M45145288500 GB 7200 RPM 3.5" Simple-Swap SATA II4 3.5" Hot-Swap SATA and NL SATA HDD81Y9774A27Z IBM 3 TB 7.2K 6Gbps NL SATA 3.5" HS HDD8 42D07825415IBM 2 TB 7200 NL SATA 3.5" HS HDD8 43W76265560IBM 1 TB 7200 SATA 3.5" HS HDD8 39M45305196500 GB 7200 RPM 3.5" Hot-Swap SATA II83.5" Hot-Swap SAS HDDs44W22445313IBM 600 GB 15 K 6 Gbps SAS 3.5" Hot-Swap HDD844W22395312IBM 450 GB 15 K 6 Gbps SAS 3.5" Hot-Swap HDD844W22345311IBM 300 GB 15 K 6 Gbps SAS 3.5" Hot-Swap HDD83.5" Hot-Swap NL SAS HDDs81Y9758A281IBM 3 TB 7.2K 6Gbps NL SAS 3.5" HS HDD842D07675417IBM 2 TB 7.2 K 6 Gbps NL SAS 3.5" HS HDD842D07775418IBM 1 TB 7.2 K 6 Gbps NL SAS 3.5" HS HDD82.5" Hot-swap SAS-SSD Hybrid Drive00AD102A4G7IBM 600GB 10K 6Gbps SAS 2.5'' G2HS Hybrid162.5" Hot-Swap NL SATA HDDs81Y9730A1AV IBM 1TB 7.2K 6Gbps NL SATA 2.5" SFF HS HDD1681Y9726A1NZ IBM 500GB 7.2K 6Gbps NL SATA 2.5" SFF HS HDD1681Y9722A1NX IBM 250GB 7.2K 6Gbps NL SATA 2.5" SFF HS HDD162.5" Hot-Swap 10K SAS HDDs00AD075A48S IBM 1.2TB 10K 6Gbps SAS 2.5'' G2HS HDD1681Y9650A282IBM 900GB 10K 6Gbps SAS 2.5" Slim-HS HDD1649Y20035433IBM 600 GB 10 K 6 Gbps SAS 2.5" SFF Slim-HS HDD1642D06375599IBM 300 GB 10 K 6 Gbps SAS 2.5" SFF Slim-HS HDD162.5" Hot-Swap 15K SAS HDDs81Y9670A283IBM 300GB 15K 6Gbps SAS 2.5" SFF HS HDD1642D06775536IBM 146 GB 15 K 6 Gbps SAS 2.5" SFF Slim-HS HDD162.5" Hot-Swap NL SAS HDDs81Y9690A1P3IBM 1TB 7.2K 6Gbps NL SAS 2.5" SFF HS HDD1642D07075409IBM 500 GB 7200 6 Gbps NL SAS 2.5" SFF Slim-HS HDD162.5" Solid state drives00W1125A3HR IBM 100GB SATA 2.5" MLC HS Enterprise SSD1643W7718A2FN IBM 200GB SATA 2.5" MLC HS SSD1649Y5839A3AS IBM 64GB SATA 2.5" MLC HS Enterprise Value SSD1649Y5844A3AU IBM 512GB SATA 2.5" MLC HS Enterprise Value SSD1690Y8643A2U3IBM 256GB SATA 2.5" MLC HS Enterprise Value SSD1690Y8648A2U4IBM 128GB SATA 2.5" MLC HS Enterprise Value SSD16* If the server has a 670 W fixed power supply, then only 4x 3.5-inch drives or 8x 2.5-inch drives can be installed.Internal backup unitsStorage host bus adaptersThe following table lists storage HBAs supported by the x3400 M3 server. Table 12. Storage adaptersPart number FeaturecodeDescription Maximumquantity supportedFibre Channel59Y19873885Brocade 4 Gb FC Single-port HBA for IBM System x359Y19933886Brocade 4 Gb FC Dual-port HBA for IBM System x346M60493589Brocade 8 Gb FC Single-port HBA for IBM System x346M60503591Brocade 8 Gb FC Dual-port HBA for IBM System x381Y1668A2XU Brocade 16Gb FC Single-port HBA for IBM System x381Y1675A2XV Brocade 16Gb FC Dual-port HBA for IBM System x342C20691698Emulex 4 Gbps FC Single-Port PCI-e HBA for IBM System x642C20711699Emulex 4 Gbps FC Dual-Port PCI-e HBA for IBM System x642D04853580Emulex 8 Gb FC Single-port HBA for IBM System x642D04943581Emulex 8 Gb FC Dual-port HBA for IBM System x681Y1655A2W5Emulex 16Gb FC Single-port HBA for IBM System x381Y1662A2W6Emulex 16Gb FC Dual-port HBA for IBM System x339R65253567QLogic 4 Gb FC Single-Port PCIe HBA for IBM System x639R65273568QLogic 4 Gb FC Dual-Port PCIe HBA for IBM System x642D05013578QLogic 8 Gb FC Single-port HBA for IBM System x642D05103579QLogic 8 Gb FC Dual-port HBA for IBM System x600Y3337A3KW QLogic 16Gb FC Single-port HBA for IBM System x300Y3341A3KX QLogic 16Gb FC Dual-port HBA for IBM System x3Converged Network Adapters (CNA)*42C18005751QLogic 10 Gb Dual Port CNA for IBM System x342C18201637Brocade 10 Gb Dual-port CNA for IBM System x3iSCSI39Y61462976QLogic iSCSI Single-Port PCIe HBA for IBM System x642C17702977QLogic iSCSI Dual-Port PCIe HBA for IBM System x6SAS44E87003583IBM 3 Gb SAS HBA v2346M09075982IBM 6 Gb SAS HBA Controller346M09123876IBM 6Gb Performance Optimized HBA1* Converged Network Adapters require SFP+ optical transceivers or DAC cables that must be purchased separately.For more information, see the list of IBM Redbooks Product Guides in the Host bus adapters category: /portals/systemx?Open&page=pg&cat=hbaPCIe SSD adaptersPCIe SSD adaptersThe server does not support High IOPS SSD adapters.Power suppliesThe server supports either one 670 W AC fixed power supply or up to two 920 W AC hot-swap redundant power supplies, providing N+N redundancy. Standard models come with one power supply, either fixed or hot-swap, depending on the model as listed in Table 2. For models with one 920 W AC hot-swap redundant power supply, you can add a second power supply by ordering the option listed in the following table.Note: If the server has a 670 W fixed power supply installed, then only up to four 3.5-inch drives can be installed or up to eight 2.5-inch drives can be installed.Table 13. Power suppliesPart number Feature code Description Maximum supported44X03815056IBM Redundant Power Supply for x3400/3500 2 (One power supply comesstandard with every model.)The power supply ships without a line cord. A line cord must be ordered separately.Note: Power supply option 44X0381 is for both the x3400 M3 and the x3500 M3. The power supply option includes three fans however these fans are only for use with the x3500 M3. They are not used in the x3400 M3. (The x3400 M3 includes physical space for the fans but there is no electrical connection for the fans in the x3400 M3.)Integrated virtualizationThe server supports VMware ESXi installed on a USB memory key. The key is installed in a USB socket inside the server. The following table lists the virtualization options.Table 14. Virtualization optionsPart number FeaturecodeDescription Maximumsupported41Y82781776IBM USB Memory Key for VMware ESXi 41 41Y82873033IBM USB Memory Key for VMware ESXi 4.11 41Y8296A1NP IBM USB Memory Key for VMware ESXi 4.1 Update 11 41Y8300A2VC IBM USB Memory Key for VMware ESXi 5.01 41Y8307A383IBM USB Memory Key for VMware ESXi 5.0 Update 11 41Y8311A2R3IBM USB Memory Key for VMware ESXi 5.11Remote managementExternal backup unitsThe server supports the external backup attachment options listed in the following table. Table 22. External backup optionsPart number DescriptionExternal tape expansion enclosures for internal tape drives87651UX1U Tape Drive Enclosure8767HHX Half High Tape Drive Enclosure87651NX1U Tape Drive Enclosure (with Nema 5-15P LineCord)8767HNX Half High Tape Drive Enclosure (with Nema 5-15P LineCord)Tape enclosure adapters (with cables)44E8869USB Enclosure Adapter Kit40K2599SAS Enclosure Adapter KitInternal backup drives supported by external tape enclosures46C5364IBM RDX Removable Hard Disk Storage System - Internal USB 160 GB Bundle 46C5387IBM RDX Removable Hard Disk Storage System - Internal USB 320 GB Bundle 46C5388IBM RDX Removable Hard Disk Storage System - Internal USB 500 GB Bundle 46C5399IBM DDS Generation 5 USB Tape Drive39M5636IBM DDS Generation 6 USB Tape Drive43W8478IBM Half High LTO Gen 3 SAS Tape Drive44E8895IBM Half High LTO Gen 4 SAS Tape Drive49Y9898IBM Half High LTO Gen 5 Internal SAS Tape DriveExternal backup units*362516X IBM RDX Removable Hard Disk Storage System - External USB 160 GB Bundle362532X IBM RDX Removable Hard Disk Storage System - External USB 320 GB Bundle362550X IBM RDX Removable Hard Disk Storage System - External USB 500 GB Bundle3628L3X IBM Half High LTO Gen 3 External SAS Tape Drive (with US line cord)3628L4X IBM Half High LTO Gen 4 External SAS Tape Drive (with US line cord)3628L5X IBM Half High LTO Gen 5 External SAS Tape Drive (with US line cord)3628N3X IBM Half High LTO Gen 3 External SAS Tape Drive (without line cord)3628N4X IBM Half High LTO Gen 4 External SAS Tape Drive (without line cord)3628N5X IBM Half High LTO Gen 5 External SAS Tape Drive (without line cord)3580S3V System Storage TS2230 Tape Drive Express Model H3V3580S4V System Storage TS2240 Tape Drive Express Model H4V3580S5E System Storage TS2250 Tape Drive Express Model H5S3580S5X System Storage TS2350 Tape Drive Express Model S533572S4R TS2900 Tape Library with LTO4 HH SAS drive & rack mount kit3572S5R TS2900 Tape Library with LTO5 HH SAS drive & rack mount kit35732UL TS3100 Tape Library Model L2U Driveless35734UL TS3200 Tape Library Model L4U Driveless46X2682†LTO Ultrium 5 Fibre Channel Drive46X2683†LTO Ultrium 5 SAS Drive Sled46X2684†LTO Ultrium 5 Half High Fibre Drive Sled46X2685†LTO Ultrium 5 Half High SAS Drive Sled46X6912†LTO Ultrium 4 Half High Fibre Channel Drive Sled46X7117†LTO Ultrium 4 Half High SAS DriveV2 Sled46X7122†LTO Ultrium 3 Half High SAS DriveV2 Sled* Note: The external tape drives listed can be ordered through System x sales channel. Server may support other IBM tape drives that are not listed in this table. Refer to IBM System Storage Interoperability Center for further information.† Note: These part numbers are the tape drives options for 35732UL and 35734UL.For more information, see the list of IBM Redbooks Product Guides in the Backup units category:/portals/systemx?Open&page=pg&cat=tapeTop-of-rack Ethernet switchesThe server supports the following top-of-rack Ethernet switches from IBM System Networking.Table 23. IBM System Networking - Top-of-rack switchesPart number DescriptionIBM System Networking - 1 Gb top-of-rack switches0446013IBM System Networking RackSwitch G8000R7309CFC IBM System Networking RackSwitch G8000F7309CD8IBM System Networking RackSwitch G8000DC7309G52IBM System Networking RackSwitch G8052R730952F IBM System Networking RackSwitch G8052F427348E IBM Ethernet Switch J48E6630010Juniper Networks EX2200 24 Port6630011Juniper Networks EX2200 24 Port with PoE6630012Juniper Networks EX2200 48 Port6630013Juniper Networks EX2200 48 Port with PoEIBM System Networking - 10 Gb top-of-rack switches7309DRX IBM System Networking RackSwitch G8264CS (Rear to Front)7309DFX IBM System Networking RackSwitch G8264CS (Front to Rear)7309BD5IBM System Networking RackSwitch G8124DC7309BR6IBM System Networking RackSwitch G8124ER7309BF7IBM System Networking RackSwitch G8124EF7309G64IBM System Networking RackSwitch G8264R730964F IBM System Networking RackSwitch G8264F7309CR9IBM System Networking RackSwitch G8264TR7309CF9IBM System Networking RackSwitch G8264TF0719410Juniper Networks EX4500 - Front to Back Airflow0719420Juniper Networks EX4500 - Back to Front AirflowIBM System Networking - 40 Gb top-of-rack switches8036ARX IBM System Networking RackSwitch G8316R8036AFX IBM System Networking RackSwitch G8316FFor more information, see the list of IBM Redbooks Product Guides in the Top-of-rack switches category: /portals/systemx?Open&page=pg&cat=torPart number DescriptionSwitched and Monitored PDUs46M4002IBM 1U 9 C19/3 C13 Active Energy Manager DPI® PDU46M4003IBM 1U 9 C19/3 C13 Active Energy Manager 60A 3 Phase PDU46M4004IBM 1U 12 C13 Active Energy Manager DPI PDU46M4005IBM 1U 12 C13 Active Energy Manager 60A 3 Phase PDU46M4167IBM 1U 9 C19/3 C13 Switched and Monitored 30A 3 Phase PDU46M4116IBM 0U 24 C13 Switched and Monitored 30A PDU46M4119IBM 0U 24 C13 Switched and Monitored 32A PDU46M4134IBM 0U 12 C19/12 C13 Switched and Monitored 50A 3 Phase PDU46M4137IBM 0U 12 C19/12 C13 Switched and Monitored 32A 3 Phase PDUEnterprise PDUs71762MX IBM Ultra Density Enterprise PDU C19 PDU+ (WW)71762NX IBM Ultra Density Enterprise PDU C19 PDU (WW)71763MU IBM Ultra Density Enterprise PDU C19 3 phase 60A PDU+ (NA)71763NU IBM Ultra Density Enterprise PDU C19 3 phase 60A PDU (NA)39M2816IBM DPI C13 Enterprise PDU without linecord39Y8923DPI 60A Three Phase C19 Enterprise PDU with IEC309 3P+G (208 V) fixed line cord 39Y8941DPI Single Phase C13 Enterprise PDU without line cord39Y8948DPI Single Phase C19 Enterprise PDU without line cordFront-End PDUs39Y8934DPI 32amp/250V Front-end PDU with IEC 309 2P+Gnd connector39Y8935DPI 63amp/250V Front-end PDU with IEC 309 2P+Gnd connector39Y893830amp/125V Front-end PDU with NEMA L5-30P connector39Y893930amp/250V Front-end PDU with NEMA L6-30P connector39Y894060amp/250V Front-end PDU with IEC 309 60A 2P+N+Gnd connectorUniversal PDUs39Y8951DPI Universal Rack PDU w/ US LV and HV line cords 39Y8952DPI Universal Rack PDU w/ CEE7-VII Europe LC39Y8953DPI Universal Rack PDU w/ Denmark LC39Y8954DPI Universal Rack PDU w/ Israel LC39Y8955DPI Universal Rack PDU w/Italy LC39Y8956DPI Universal Rack PDU w/South Africa LC39Y8957DPI Universal Rack PDU w/UK LC39Y8958DPI Universal Rack PDU with AS/NZ LC39Y8959DPI Universal Rack PDU w/China LC39Y8962DPI Universal Rack PDU (Argentina)39Y8960DPI Universal Rack PDU (Brazil)39Y8961DPI Universal Rack PDU (India)0U Basic PDUs46M4122IBM 0U 24 C13 16A 3 Phase PDU46M4125IBM 0U 24 C13 30A 3 Phase PDU46M4128IBM 0U 24 C13 30A PDU46M4131IBM 0U 24 C13 32A PDU46M4140IBM 0U 12 C19/12 C13 60A 3 Phase PDU46M4143IBM 0U 12 C19/12 C13 32A 3 Phase PDURack cabinetsThe server supports the rack cabinets listed in the following table. Tower-to-Rack Conversion Kit (part number 69Y0893, 5Ux26" Tower to Rack Conversion Kit for x3400/x3500) is required for the server to be installed in a rack.Table 26. Rack cabinetsPart number Description69Y08935Ux26" Tower to Rack Conversion Kit for x3400/x3500201886X IBM 11U Office Enablement Kit14102RX IBM eServer Cluster 25U Rack93072PX IBM 25U Static S2 Standard Rack93072RX IBM 25U Standard Rack93074RX IBM 42U Standard Rack93074XX IBM 42U Standard Rack Extension14104RX IBM 42U S2 standard rack93084EX IBM 42U Enterprise Expansion Rack93084PX IBM 42U Enterprise Rack93604EX IBM 42U 1200 mm Deep Dynamic Expansion Rack93604PX IBM 42U 1200 mm Deep Dynamic Rack93614EX IBM 42U 1200 mm Deep Static Expansion Rack93614PX IBM 42U 1200 mm Deep Static Rack93624EX IBM 47U 1200 mm Deep Static Expansion Rack93624PX IBM 47U 1200 mm Deep Static RackFor more information, see the IBM 47U and 42U 1200mm Deep Racks at-a-glance guide, available from: /abstracts/tips0796.html?OpenTrademarksLenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web athttps:///us/en/legal/copytrade/.The following terms are trademarks of Lenovo in the United States, other countries, or both:Lenovo®BladeCenter®RackSwitchServeRAIDServerGuideServerProven®System x®The following terms are trademarks of other companies:Intel® and Xeon® are trademarks of Intel Corporation or its subsidiaries.Linux® is the trademark of Linus Torvalds in the U.S. and other countries.Microsoft®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.Other company, product, or service names may be trademarks or service marks of others.。

IBM XIV系列存储快速维护手册

IBM XIV系列存储快速维护手册

IBM XIV系列存储快速维护手册目录一、XIV的基本架构和组成: (3)二、XIV的基本管理: (5)三、XIV的安装环境要求: (6)四、XIV安装上电 (8)五、如何升级XIV的微码 (11)六、如何收集XIV的System Data(XRAY) (11)七、如何通过GUI更换单个的DDM (15)八、如何通过GUI更换一个模块(Interface Module 或Data Module) (20)附录A:参考文档: (25)一、XIV的基本架构和组成:IBM的XIV系统存储2810-A14,提供了高性能、可扩展性、易于管理功能。

同时采用了SATA磁盘,更加降低了单位容量的成本。

XIV存储主要包括以下组成部分:1.6个主机系统接口模块(Interface Module),它提供FC以及iSCSI接口,同时每个模块包括了12块1TB的SATA硬盘。

2.9个数据模块(Data Module),每个模块包括了12块1TB的SATA硬盘。

3.3组不间断电源模块(UPS),提供掉电保护功能。

4.2个以太网交换机,提供模块间的数据交换功能。

5.一个维护模块(Maintenance Module)6.一个自动电源分配管理模块(ATS),管理外部输入电源的冗余。

7.一个Modem,连接到维护模块,提供CallHome和远程维护。

除此之外,为了方便和外部系统相连接,XIV将所有要和外部相连接的端口都集中到了一个叫Patch Panel的模块。

Patch Panel位于机柜后面右上角。

具体的端口定义如下图。

二、XIV的基本管理:XIV主要是通过XIV Storage Manager GUI进行管理的。

通过GUI完成以下的管理功能:1.XIV硬件的维护和备件的更换2.XIV存储容量的逻辑划分3.XIV和主机系统连接的配置管理4.系统性能的检测5.系统快照、拷贝、远程拷贝、数据迁移功能的管理除此之外XIV还提供了命令行方式的管理XCLI,所有能在GUI中完成的功能也都够通过XCLI完成。

IBM SPSS Modeler - Essentials for R:安装指示信息说明书

IBM SPSS Modeler - Essentials for R:安装指示信息说明书
安装 IBM SPSS Modeler - Essentials for R for Windows . . . . . . . . . . . . . . 8 安装 IBM SPSS Modeler - Essentials for R for UNIX . . . . . . . . . . . . . . . . 9
mkdir ~/Rsource 2. 下载用于构建 R 的源代码(例如,R-3.3.3.tar.gz),并将其保存到临时目录。 3. 切换至临时目录。例如,在命令提示符处输入:
cd ~/Rsource 4. 将 R 源解压缩并解包至临时目录。例如,在命令提示符处输入:
v 对于使用 apt-get 的 Linux 分发版,请使用以下命令安装 X11 客户机和服务器软件: apt-get install xorg xterm apt-get install xsever-xorg xserver-xorg-core xserver-xorg-dev apt-get install xvfb
除了 X11 之外,还建议确保在安装 R 之前安装 tcl/tk。
通过软件包管理器安装 R
发行版的存储库可能包括 R。如果是这样,您可以使用发行版的标准程序包管理器(例如,RPM Package Manager 或 Synaptic Package Manager)来安装 R。 v 对于使用 yum 的 Linux 分发版,您可以使用 yum install R 安装 R。 v 对于使用 apt-get 的 Linux 分发版,您可以通过以下命令安装 R:
1
先决条件
您将安装 Essentials for R 的目标计算机必须安装 X11。如果目标计算机有物理显示器,那么它很可能安装了 X11。后续步骤描述了安装 X11 的过程(如有必要)。 1. 安装 X11 客户机和服务器

IBM XIV系列存储快速维护手册

IBM XIV系列存储快速维护手册

IBM XIV系列存储快速维护手册目录一、XIV的基本架构和组成: (3)二、XIV的基本管理: (5)三、XIV的安装环境要求: (6)四、XIV安装上电 (8)五、如何升级XIV的微码 (11)六、如何收集XIV的System Data(XRAY) (11)七、如何通过GUI更换单个的DDM (15)八、如何通过GUI更换一个模块(Interface Module 或Data Module) (20)附录A:参考文档: (25)一、XIV的基本架构和组成:IBM的XIV系统存储2810-A14,提供了高性能、可扩展性、易于管理功能。

同时采用了SATA磁盘,更加降低了单位容量的成本。

XIV存储主要包括以下组成部分:1.6个主机系统接口模块(Interface Module),它提供FC以及iSCSI接口,同时每个模块包括了12块1TB的SATA硬盘。

2.9个数据模块(Data Module),每个模块包括了12块1TB的SATA硬盘。

3.3组不间断电源模块(UPS),提供掉电保护功能。

4.2个以太网交换机,提供模块间的数据交换功能。

5.一个维护模块(Maintenance Module)6.一个自动电源分配管理模块(ATS),管理外部输入电源的冗余。

7.一个Modem,连接到维护模块,提供CallHome和远程维护。

除此之外,为了方便和外部系统相连接,XIV将所有要和外部相连接的端口都集中到了一个叫Patch Panel的模块。

Patch Panel位于机柜后面右上角。

具体的端口定义如下图。

二、XIV的基本管理:XIV主要是通过XIV Storage Manager GUI进行管理的。

通过GUI完成以下的管理功能:1.XIV硬件的维护和备件的更换2.XIV存储容量的逻辑划分3.XIV和主机系统连接的配置管理4.系统性能的检测5.系统快照、拷贝、远程拷贝、数据迁移功能的管理除此之外XIV还提供了命令行方式的管理XCLI,所有能在GUI中完成的功能也都够通过XCLI完成。

IBM X系列服务器之IMM初探

IBM X系列服务器之IMM初探作者:李琳来源:《中国科技博览》2015年第28期[摘要]本文简单介绍了IBM X系列服务器,详细说明IMM集成管理模块的使用及各种功能。

[关键词]IBM X系列服务器,IMM集成管理模块中图分类号:P154 文献标识码:A 文章编号:1009-914X(2015)28-0045-02一、X系列服务器简介IBM服务器家族种类非常丰富齐全,目前共有4条产品线:基于?Intel架构的服务器X 系列(xSeries)、中型企业级服务器I系列(iSeries)、UNIX?服务器p系列(pSeries)和大型主机Z系列(zSeries)。

这四大系列基本都包括了从入门级到企业级的各种档次的服务器产品,在结构上也有塔式、机架式、刀片式和机柜式之分。

X系列服务器的原名是IBM eServer xSeries系列,是IBM服务器品牌之一。

IBM在1998年提出X系列服务器设想,而使X系列真正意义上进入到应用领域,还是到了2001年之后。

相比较IBM大型机的诞生时间,X系列所关注的目标是面向中小企业,因此要比面向金融行业的大型机稍晚一些。

2006年5月,?IBM宣布将IBM?eServer?xSeries改名为IBM?System?x,后面的型号也全面更新,如原来的高性能服务器x260更名为x3800、x366更名为x3850、x460更名为x3950,其中x3代表这些系统是基于X3架构,倒数第三个数字代表功能,数字越大功能越强;倒数第二个数字代表塔式(0)还是机架式(5);最后一个数字代表采用Intel(0)或AMD(5)的处理器。

二、IMM的访问1、IBM服务器判断故障的方法IBM服务器素来以稳定的运行著称,但是有时候难免也会出现一些故障。

在出现故障时怎么排除故障,除了依靠工作经验判断定位故障外,还有其它诸如通过查看光通路诊断面板,或收集各方面的日志等来判断机器故障。

需要收集的日志一般有DSA、RAID、BMC,再有就是通过IMM管理功能来判断故障。

IBM Power System POWER9服务器安装Ubuntu的快速入门指南说明书

Installing Ubuntu on IBM Power SystemPOWER9 servers with a USB deviceVersion 1.0.0IBM®Quick Start Guide for installing Linux on IBM Power System POWER9 serversThis guide helps you install Ubuntu on a Linux on Power Systems POWER9 server.OverviewUse this information to install Ubuntu on a non-virtualized or bare metal IBM Power System LC server. This procedure follows these general steps:•Download the Ubuntu ISO file•Create a bootable USB device•Connect to the BMC firmware to set up network connection•Install Ubuntu from USB deviceDownload your ISO files from the Ubuntu release website. Look for the PowerPC64 Little-Endian server install image. Supported Ubuntu releases include:•Ubuntu 18.04: /releases/18.04/release/For a list of supported distributions, see Supported Linux distributions and virtualization options for POWER8 and POWER9 Linux on Power systems.1Step 1: Creating a bootable USB deviceUse one of the following USB devices:•USB attached DVD player with a single USB cable to stay under 1.0 Amps•8 GB 2.0 USB flash driveTo create the bootable USB device, follow the instructions in the Ubuntu Community Help Wiki at https:// /community/Installation/FromUSBStick2Step 2: Completing the prerequisites and booting yourfirmwareBefore you power on the system, ensure that you have the following items:•Ethernet cable•VGA monitor. The VGA resolution must be set to 1024x768-60Hz.•USB Keyboard•Power cords and outlet for your system.•Bootable USB deviceComplete these steps:•If your system belongs in a rack, install your system into that rack. For instructions, see IBM Power Systems information at https:///support/knowledgecenter/.•Connect an Ethernet cable to the embedded Ethernet port next to the serial port on the back of your system.Connect the other end to your network.•Connect your VGA monitor to the VGA port on back of system.•Connect your USB keyboard to an available USB port•Connect the power cords to the system and plug them into the outlets.At this point, your firmware is booting. Wait for the green LED on the power button to start flashing, indicating that it is ready to use. If your system does not have a green LED indicator light, then wait 1 to 2 minutes.3Step 3: Configuring the IP addressTo set up or enable your network connection to the OpenBMC firmware, use the Petitboot bootloader interface.Follow these steps:a.Power on your server using the power button on the front of your system. Your system will power on to thePetitboot bootloader menu. This process takes about 1 - 2 minutes to complete. Do not walk away from your system! When Petitboot loads, your monitor will become active and you will need to push any key in order to interrupt the boot process.b.At the Petitboot bootloader main menu, select Exit to Shell.c.Run ipmitool lan print 1. If this command returns an IP address, verify that is correct and continue. Toset a static IP address, follow these steps:i.Set the mode to static by running this command: ipmitool lan set 1 ipsrc staticii.Set your IP address by running this command: ipmitool lan set 1 ipaddr ip_address where ip_address is the static IP address that you are assigning to this system.iii.Set your netmask by running this command: ipmitool lan set 1 netmask netmask_address where netmask_address is the netmask for the system.iv.Set your gateway server by running this command: ipmitool lan set 1 defgw ipaddr gateway_server where gateway_server is the gateway for this system.v.Confirm the IP address by running the command ipmitool lan print 1 again.Note: This network interface is not active until after you perform the following steps.d.To reset your firmware, run the following command: ipmitool mc reset cold.This command must complete before continuing the process; however, it does not return any information. To verify that this command has completed, ping your system BMC address (the same IP address used in yourIPMItool command). When the ping returns successfully, continue to the next step.Note: If your ping does not return successfully within a reasonable amount of time (2 - 3 minutes), try these additional steps:i.Power your system off with this command: ipmitool power off.ii.Unplug the power cords from the back of the system. Wait 30 seconds and then apply power to boot BMC. 4Step 4: Powering on your server with OpenBMC commandsNote: After your system powers on, the Petitboot interface loads. If you do not interrupt the boot process by pressing any key within 10 seconds, Petitboot automatically boots the first option.To power on your server from a PC or notebook that is running Linux, follow these steps:•Default user name: root•Default password: 0penBmc (where, 0penBMC is using a zero and not a capital O)a.Open a terminal program on your PC or notebook.b.Log in to the BMC by running the following commands.ssh root@<BMC server_ip_address>root@<BMC server password>where BMC server_ip_address is the IP address of the BMC and BMC server password is the password toauthenticate.c.To power on your server, run the following command:$ root@witherspoon:~# obmcutil powerond.Connect to OS console and use the default password 0penBmc.ssh -p 2200 root@<BMC server_ip_address>root@where BMC server_ip_address is the IP address of the BMC and BMC server password is the password toauthenticate.5Step 5: Configuring PetitbootAfter the system powers on, the Petitboot bootloader scans local boot devices and network interfaces to find bootoptions that are available to the system.a.Insert your bootable USB device into the front USB port. Petitboot displays the following option:Note: Select Rescan devices if the USB device does not appear. If your device is not detected, you may have to try a different type.b.On the Petitboot main screen, select the Debian GNU/Linux installer boot option and then press Enter.6Step 6: Completing your installationAfter you select to boot the Ubuntu installer, the installer wizard walks you through the steps.a.Follow the installation wizard for Ubuntu to set up disk options, your user name and password, time zones, andso on. The last step is to restart your system.Note: The Ubuntu installation process uses DHCP by default during installation. If you are not using DHCP, youneed to configure the network manually. Follow these steps:i.On the Configuring the network with DHCP screen, click Cancel.ii.Click Continue.iii.Select Configure your network manuallyiv.Enter your IP address and select Continue.v.Enter your Netmask and select Continue.vi.Enter or confirm the gateway for your IP address and select Continue.vii.(Optional) Enter the Name server address and select Continue.viii.E nter a hostname for your system and select Continue.ix.Select a mirror of the Ubuntu archive.x.Confirm the Ubuntu archive mirror.xi.(Optional) Enter HTTP proxy information and select Continue.Note: While your system is restarting, remove the USB device.b.After the system restarts, Petitboot displays the option to boot the Ubuntu with Linux release number. Select thisoption and press Enter.Notes:•In Ubuntu, the opal-prd (Processor Runtime Diagnostics) package that is required for runtime detection and handling of Power processor errors on systems that are running OpenPower firmware is not installed by default.Run the following command to install this package:apt-get install opal-prdMore informationFor more information, see the following resources:•Ask Ubuntu website at /•IBM Knowledge center at https:///support/knowledgecenter/•The Linux on Power® developer portal at Linux on Power developer portal.© Copyright IBM® Corp. 2015, 2018. US Government Users Restricted Rights - Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.IBM, the IBM logo, and ® are trademarks or registered trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the web at "Copyright and trademark information" (/legal/copytrade.shtml).。

IBM-存储-DS8000使用及维护手册

DS8000使用及维护手册——VER 1.0目录第1章IBM DS8000概述 (4)第2章环境说明 (6)2.1DS8000体积和重量参数 (6)2.2DS8000机房环境要求 (6)2.3DS8000机房电气要求 (7)2.4DS8000机房通讯要求 (8)2.5DS8000机房工作环境要求 (8)2.6DS8000机房安全性要求 (8)2.7DS8000装机前要求 (8)2.8DS8000现场环境C HECK L IST (9)2.9DS8000到货情况C HECK L IST (9)2.10DS8000电源示意图和具体度量、连接方法 (9)第3章硬件说明 (12)3.1IBM S YSTEM S TORAGE DS8300 (13)3.2DS8000 STORAGE ENCLOSURE CONNECTIVITY (14)第4章规划DS8000存储器的安装 (15)4.1公司信息 (15)4.2管理控制台网络设置 (16)4.3远程支持设置 (18)4.4安装需求 (21)4.5磁盘大小规划与主机名规划 (23)第5章DS8000 逻辑配置 (24)5.1安装DSCLI (24)5.2激活DS8000L ICENSE (25)5.3DS8000逻辑配置 (26)第6章DS8000日常维护 (42)第7章DS8300 存储规划 (44)7.1IO卡规划 (44)7.2存储规划 (45)第8章SAN规划举例 (49)8.1SAN与Z ONE简介 (49)8.2关于光纤布线 (51)8.3Z ONE的划分 (51)8.4SAN布线规划 (52)第1章IBM DS8000概述IBM DS8000是设计为支持连续操作的高性能、高容量的磁盘存储器系列。

DS8000系列的各型号(机器类型 2107)使用 IBM POWER5服务器技术,该技术与IBM Virtualization Engine 技术集成。

IBMPC服务器培训讲义

目录一、IBM产品学习..................................................... - 1 -1.1 IBM PC Server产品介绍....................................... - 1 -1.2 IBM PC Server官方网站介绍................................... - 3 -1.3 IBM PC Server常用手册....................................... - 6 -1.4 IBM PC Server常用技术....................................... - 7 -1.5 IBM PC Server OS安装....................................... - 10 -1.6 IBM PC Server常见配置...................................... - 10 -1.7 IBM PC Server常用软件...................................... - 11 -二、IBM PC Server常见故障诊断和解决办法............................ - 19 -2.1状态确定.................................................... - 19 -2.2故障定位.................................................... - 19 -2.3常见故障解决................................................ - 32 -一、IBM产品学习1.1 IBM PC Server产品介绍1. IBM NetFinity:一般来说,IBM X系列就代表了IBM的PC服务器;而IBM提出X系列的概念就是从Netfinity开始的,我们现在几乎已经看不到了。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
相关文档
最新文档