二 、CONDITIONAL ............................................................................................................................................16 1、Analog Compare ........................................................................................................................................16 2、AND ...........................................................................................................................................................16 3、Binary Decoder ..........................................................................................................................................17 4、Buffer .........................................................................................................................................................18 5、Exclusive NOR...........................................................................................................................................19 6、Exclusive OR..............................................................................................................................................20 7、NAND ........................................................................................................................................................21 8、Negative Transition Gate............................................................................................................................21 9、NOR ...........................................................................................................................................................22 10、NOT..........................................................................................................................................................22 11、OR ............................................................................................................................................................23 12、Transition Gate .........................................................................................................................................24 13、Truth Table ...............................................................................................................................................24

iOAv2004功能说明书.docx

iOAv2004功能说明书.docx
1)电子邮件
提供个人电子邮件的收发、转发、删除、保存等功能。系统的主要功能特点包括:
■有新邮件时,系统会自动进行提示。
■HTM1.格式文本支持
■邮件系统支持POP3邮件和INTERNET邮件
注:电子邮件寄
2)留言消息
留言信息指系统用户相互之间的交流沟通的简要信息,它不象En1.ai1.一样需要强大的效劳系统的支持,但能够方便地传递各种简要的信息。
高平安性
就系统体系而言,创新通软提供的基于三层结构的系统系统具有如下的平安特性:
■更多层次的保护
■中间层的设置隔离了客户端对数据库的直接访问。
■平安敏感信息实行集中式管理。
■业务系统中的用户身份给证、权限控制与操作系统、数据库系统进行优化集成。
■在网络通信中设置防火墙(FireWa1.1),以及应用端到端的高强度加密保护。
具体内容包括:
■发送留言通知
可同时发送给多个人员
■留言通知回复
添加回复内容
■留言通知转发
3)工作任务/日历
为用户提供灵活的日历、周历和月历方式显示、有效地安排和组织办公日程。
具体内容包括:
■任务日历视图
日、周、月视图
■任务状态视图
待办、办理中、结案、延期任务视图
■任务定义
定义任务
4)个人文档/便签
用于存储和管理私有的个人文档和信息。
■网络远程办公节约纸张、差旅、会议、通讯等方面的费用
■提高员工日常办公效率
■提高政策、制度、任务指标等信息的传播、共享速度
■提高各部门协同工作能力
■增强对下属部门人员的业务监管能力,提高其信息透明度
另外,创新通软iOA还能带来增值的战略性投资回报:
■建设透明化、协作型、学习型、以市场为中心的企业办公文化

Mirage MMS-2A 云基于的多媒体服务器说明书

Mirage MMS-2A 云基于的多媒体服务器说明书

M irage m m s·2a SpecificationsDeliver up to three independent streams of pure, high-resolutionaudio to a multi-room system. A new generation of the world’sfirst cloud-based media server, the MMS-2A will store, sync,schedule and stream an entire music collection along with themost popular online streaming services.©2006–2016 Autonomic Controls, Inc. Autonomic and TuneBridge are registered trademarks of Autonomic Controls, Inc. +1 914 598 1647All other trademarks are property of their respective owners. Specifications are based on current revision and may change without notice. 071416Mms·2aStreaming ServicesDeezer, iHeartRadio, Murfie, Napster, PANDORA ® Internet Radio, SiriusXM Internet Radio, Slacker Radio, Spotify, TIDAL, TuneIn, guest streaming via AirPlayAudio Formats .aif, .aifc, .aiff, .au, .cda, .flac, .m4a, .m4p, .mp2, .mp3, .mpa, .rmi, .snd, .wav, .wma, .wpl Internal Storage 128 GB SSD hard drive; holds approximately 25,000 songs External Storage Expandable storage via USB external hard drives Multi-Source Pre-Amp OutputAnalog (1) analog, unbalanced, stereo, line level audio output Digital(1) Stereo PCM, Coaxial, RCA type(1) Stereo USB for connection to external DAC Audio ProcessorRealtek ALC662Digital-to-Analog Conversion High Resolution 24-bit/96 kHzSupported Sample Rates Digital outputs selectable 44.1 kHz/48 kHz/96 kHz/192 kHz at 16-bit or 24-bit resolution Master Volume -80 dB to +20 dB Frequency Response <10 Hz to 48 kHz S/N Ratio98 db, A weighted Dynamic Range >110 dB Channel Separation >90 dBVideo Outputs HDMI (1920 X 1080); VGA Digital Image Formats (for video slideshow).bmp, .jpg, .png, .tifLAN Connection(1) 8-wire RJ45 with 2 LED indicators; 10/100/1000 Mbps BaseT Ethernet port; green LED indicates link status; yellow LED indicates Ethernet activity Power Connection 100–240V AC ~ 50–60Hz: External power supply DC 12 V @ 5A; Mates with removable power cordLocal Synchronization Mirage Media Sync for both Mac and Windows:Download from Mirage Web configuration under Firmware tab Cloud-based Synchronization Mirage Cloud Sync (fees for online storage may apply)Control System ProtocolsIP , 2-way documented APIControl InterfacesAMX, Command Fusion, Control4, Crestron, Elan, KNX, Leviton, Lutron, ON Controls, RTI, Savant, URC, Windows/Mac, on-screen display (OSD),mobile devices and computers, Mirage Media Controller for Apple iPad, iPhone/iPod Touch, Android and Amazon Kindle External Controls + Indicators Power On/OffEnvironmental Requirements Humidity: 10% to 90% RH (non-condensing) Temperature: 32° to 104°F (0° to 40°C)Main Power Consumption 20 Watts @ 100–240V AC ~ 50–60Hz USB (4) USB 2.0CoolingFanless, passive cooling designDimensions with feet 2.25" H x 17" W x 10" D (5.7cm x 43.1cm x 25.4cm)Dimensions without feet 1.7" H (4.3cm); fits 1RU Net Weight 5 Ibs. (2.27 kg)Mounting (2) rack ears (included); (4) screw-on feet with pads (included)Warranty2-year limited warrantyAudiophile Quality SoundSupports reference quality, high resolution 24-bit/96kHz content, perfectly rendered through analog, coaxial digital and USB outputs.Mass ContentPlay uncompressed, lossless audio formats, and complete the infinite playlist with the most popular streaming services, internet radio and music via AirPlay.Cloud AccessAggregate music across multiple Mirage Media Servers into a single collection, and synchronizefragmented libraries automatically.Virtually Unlimited ZonesDistribute up to six independent streams of audio up to as many as 96 zones with any combination of Mirage Amplifiers.Integrated Control OptionsStandalone control options include the Mirage Media Controller app for iOS and Android devices, Airplay control and the Mirage web interface.Pre-programmed control modules are available to integrate with all of the major control systems: Crestron, Control4, RTI,Savant, URC, AMX and others.。

快思聪智能家居系统说明

快思聪智能家居系统说明

快思聪智能家居方案目录第一章智能家居需求分析 (3)1、什么是智能家居 (3)2、智能化家居代表未来趋势 (3)第二章快思聪智能家居中央控制系统 (5)1、智能灯光系统 (7)2、HVAC空调系统 (7)3、背景音乐系统(选配) (7)4、安防及摄像监控系统 (8)5、音视频分配系统(选配) (8)6、家庭影院系统(选配) (9)7、电动窗帘、电动遮阳蓬系统 (9)8、电话控制系统(选配) (9)9、远程网络遥控系统 (10)第三章让您真正受益于快思聪智能家居 (11)1、高度智能化 (11)2、操作更简单 (13)3、使用更方便 (14)4、墙面更整洁 (14)5、居家更安全 (16)6、生活高品质 (17)第四章各子系统功能描述 (19)1、智能灯光系统 (19)2、HVAC空调系统 (24)3、背景音乐系统 (27)音/视频设备整体控制 (31)使用音/视频控制中的个人收藏 (32)4、音视频分配系统 (33)5、安防及摄像监控系统 (37)6、家庭影院系统 (40)7、电动窗帘、电动遮阳蓬系统 (42)8、电话控制系统 (43)第五章快思聪智能家居产品目录 (50)1、触摸屏系列产品 (50)⑴Isys i/O TM系列触摸屏 (50)⑵Isys®系列触摸屏 (51)⑶快思聪掌上无线触摸屏 (53)⑷快思聪按键面板 (54)⑸其它触摸屏 (55)2、控制系统主机系列产品 (56)⑴PRO2/AV2专业双总线型控制主机 (56)⑵CP2E/CP2轻巧型控制主机 (57)⑶MC2E/MC2W控制主机 (58)⑷MP2E/MP2集成AV的控制主机 (58)⑸PAC2专业自动控制主机 (59)⑹其它控制主机 (60)3、智能灯光系列产品 (60)⑴iLUX智能灯光控制 (61)⑵CLX系列通道调光器模块 (62)⑶其它灯光及自动化产品 (63)4、HVAC空调系列产品 (63)⑴自动调温器 (63)⑵CG-EIB EIB控制总线接口模块 (63)⑶CGELON-240 LonWorks控制总线接口模块 (64)5、背景音乐系列产品 (65)⑴AESI Adagio™ 娱乐系统 (65)⑵AAS Adagio™ 音频服务器 (66)⑶APAD 墙装LCD控制面板 (67)⑷CENI-IDOC Apple iPod控制界面 (67)6、安防及摄像监控系列产品 (68)⑴快思聪内置的数字、模拟信号输入口 (68)⑵快思聪针对第三方安防设备的接口 (68)7、音视频分配系列产品 (70)⑴C2N-IADS30X24音频分配器 (70)⑵C2N-IVDS24X24视频分配器 (70)8、家庭影院系列产品 (72)⑴C2N-DAP8 7.1 环绕立體声处理器 (72)⑵CNAMPX-7X200 7声道环绕功放器 (73)9、电动窗帘、电动遮阳幕系列产品 (74)⑴CNPCI-8强电继电器控制模块 (74)⑵C2N-SDC窗帘和遮阳蓬控制器 (74)10、电话控制系列产品 (75)附录一、快思聪公司简介 (76)1、美国快思聪(C RESTRON)公司简介 (76)2、快思聪全球领先的技术 (76)3、快思聪获奖的产品 (77)4、快思聪产品被全球关注 (79)5、快思聪公司的3P (80)附录二、智能家居工程案例 (81)第一章智能家居需求分析1、什么是智能家居“智能家居”(Smart Home),又称智能住宅。

智能合成2系列FPGA SoC设备USB OTG功能演示指南说明书

智能合成2系列FPGA SoC设备USB OTG功能演示指南说明书

USB OTG Capabilities of SmartFusion2SoC FPGA DevicesDemo GuideJune 2014S u p er se d e dUSB OTG Capabilities of SmartFusion2 SoC FPGA DevicesRevision HistoryConfidentiality StatusThis is a non-confidential document.Date RevisionChange 23 June 20142Third Release 29 November 20131Second release 10 October 2013First releaseS u p er se d e dUSB OTG Capabilities of SmartFusion2 SoC FPGA Devices Demo GuideTable of ContentsPreface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4About this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Microsemi ® Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41USB OTG Capabilities of SmartFusion2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-5Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Demo Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Demo Design Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Demo Design Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Setting up the Demo Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Board Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Running the Demo Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11SmartFusion2 USB OTG Controller Acting as USB Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13SmartFusion2 USB OTG Controller Acting as USB Host . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Appendix 1: Board Set up for USB OTG Controller in USB Device Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Appendix 2: Board Setup for USB OTG Controller in USB Host Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Appendix 3: Jumper Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17A List of Changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-18B Product Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-19Customer Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Customer Technical Support Center . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Website . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Contacting the Customer Technical Support Center . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Email . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19My Cases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Outside the U.S. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20ITAR Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20S u p er se d e dPrefaceAbout this documentThis demo is for SmartFusion ®2 system-on-chip (SoC) field programmable gate array (FPGA) devices. It explains the universal serial bus (USB) 2.0 on-the-go (OTG) feature with the help of USB mass storage class.Intended AudienceSmartFusion2 devices are used by:•FPGA designers •Embedded designers •System-level designersReferencesMicrosemi ® Publications•SmartFusion2 Microcontroller Subsystem User Guide•Configuring Serial Terminal Emulation Programs TutorialRefer to the following web page for a complete and up-to-date listing of SmartFusion2 device documentation: /soc/products/smartfusion2/docs.aspx .S u p er se d e dUSB OTG Capabilities of SmartFusion2IntroductionMicrosemi offers a reference design for SmartFusion2 SoC FPGA devices that demonstrates the USB controller OTG feature of the SmartFusion2 FPGA and implements the USB mass storage class. The reference design runs on the SmartFusion2 Development Kit. The SmartFusion2 SoC FPGA device contains a USB OTG controller as part of the microcontroller subsystem (MSS). This demo guide describes the mechanism for the USB communication between the SmartFusion2 device and external USB host/USB device/USB OTG protocol compliant devices provided by the SmartFusion2 USB OTG controller.OTG is the USB 2.0 mode of operation where USB 2.0 OTG controller works as either the USB host or the USB device based on the target device and type of the plug connected to the USB OTG controller.Refer to the SmartFusion2 Microcontroller Subsystem User Guide for more information on USB OTG controller and its operations.Table 1 • Resource Details Resource Details DescriptionHardware Resources•SmartFusion2 Development Kit, Rev C or later that has:–FlashPro4 programmer –12 V adapter–USB A to Mini-B cable (for serial communication)–Micro-A to B receptacle USB cable (to connect to the USB drive)–Micro-B to A USB cable (to connect the SmartFusion2Development Kit board with the host PC)Rev C or LaterHost PC (or Laptop)Any 64-bit windows operating system Software ResourcesLibero ® System-on-Chip (SoC) for viewing the design filesv11.3FlashPro programming software v11.3USB to UART drivers–S u p er se d e dUSB OTG Capabilities of SmartFusion2Demo DesignIntroductionThe demo design files are available for download from the following path in the Microsemi website:/download/rsc/?f=sf2_usb_otg_demo_df .The demo design files include:•Libero SoC project •STAPL programming file •readme.txt fileFigure 1 shows the top level structure of the design files. For further details, refer to the readme.txt file.Figure 2 describes the demo architecture.Note:MSS USB drivers are provided along with the design files. These drivers are customized and usedin the demo.Figure 1 • Demo Design Files Top Level StructureFigure 2 • Top Level Block Diagram of the DemoseUSB OTG Capabilities of SmartFusion2 SoC FPGA Devices Demo GuideDemo Design FeaturesThe main objective of the demo is to show OTG capability with basic USB mass storage class. The demo design performs the following operations:•Switching the USB OTG controller operation between Host mode and Device mode based on the target device and type of the plug connected to the USB OTG controller.•Device mode operation –Displaying the on-board SPI flash (8 MB) as storage medium in host PC.•Host mode operation–Detecting the USB 2.0 complaint USB mass storage device connected to the USB OTG controller and listing the file names. The current firmware implementation is tested with following USB 2.0 complaint USB mass storage devices (USB flash drives) that fall under the Memory stick category:•Sandisc Cruzer Blade TM - 16 GB/8 GB/4 GB/1 GB•Kingston DataTraveler ® - 4 GB/2 GB •Kingston ® DataTraveler ®109 - 8 GB •Transcend JetFlash ® - 4 GBDemo Design DescriptionThe USB OTG controller in the SmartFusion2 device can be configured to operate in theUSB device mode/USB host mode/USB OTG mode. In USB OTG mode, the USB OTG controller acts as either USB device or USB host based on the target device and type of the plug connected to the USB OTG controller.If the Micro-A end of the cable is plugged into the SmartFusion2 device through the external PHY , the USB controller takes the role of the host and goes into Host mode. Host mode flag is set to 1.If the Micro-B end of the cable is plugged in, the USB controller goes into Peripheral mode and Host mode flag is set to 0.The demo design application initializes the USB Host mode stack and USB Device mode stack to operate in USB OTG mode. When the USB OTG controller enters into Device mode, the application initializes the USB mass storage class and registers with the MSS USB Device mode driver. On-board SPI flash memory (8 MB) is used as a storage medium in the USB Device mode operation and read/write operations can be performed.When the USB OTG controller enters into Host mode, the application registers the USB mass storage class with the MSS USB Host mode driver. The application detects the connected mass storage device and lists the files names. The application uses the FatFs file system library to access the files from the target USB mass storage device.Refer to the following website for more information on FatFs file system:/fsw/ff/00index_e.html.S u p er se d e dUSB OTG Capabilities of SmartFusion2USB OTG Mode Execution FlowFigure 3 describes the USB OTG mode execution flow.The demo application configures MMUART_0 for serial communication, SPI_0 to access SPI-Flash, and GPIO to keep the USB controller out of reset. The application registers the USB callback functions and USB interrupt service routine to handle the USB events like connect/disconnect, Host mode specific events and Device mode specific events.When a SmartFusion2 device is connected to the host PC with Micro-B to A USB cable, the USB connect interrupt is generated and Host mode flag is set to 0. Now the USB controller enters into mass storage class device mode and starts responding to commands from host PC. The SmartFusion2 on-board SPI-Flash is accessed by the host PC as a disk drive/volume in USB Device mode.When the Micro-A to B receptacle USB cable with USB mass storage device is connected to the SmartFusion2 device, the connect interrupt is generated and Host mode flag is set to 1. Now, the USB controller switches to Host mode from Device mode and accesses the USB mass storage device. When the USB mass storage device is unplugged from the SmartFusion2 device, Host mode flag is set to 0 and disconnect interrupt is generated. Now the application releases Host mode driver and waits to enter into either Device mode or Host mode based on the target device and type of the plug connected to the USB controller.Figure 3 • USB OTG Execution FlowS u pUSB OTG Capabilities of SmartFusion2 SoC FPGA Devices Demo GuideSetting up the Demo DesignUse the following steps to setup the demo:1.Connect the FlashPro4 programmer to the J59 connector of the SmartFusion2 Development Kitboard.2.Connect the host PC to the J24 connector provided on the SmartFusion2 Development Kit boardusing the USB A to Mini-B cable.3.Make sure that the USB to UART bridge drivers are automatically detected (download andinstall the drivers from www /soc/documents/CDM_2.08.24_WHQL_Certified.zip).4.Of the four COM ports, select the one with Location as on USD Serial Converter D . Figure 4shows an example of Device Manager window that has the USB Serial Port and its properties showing the port number and location. The COM port number is required to run the demo design, make a note of it.5.Connect the jumpers on the SmartFusion2 Development Kit board, as shown in Table 2 onpage 10. For more information on jumper locations, refer to "Appendix 3: Jumper Locations" on page 17.–Caution: Before making the jumper connections, switch off the power supply switch, SW7.Figure 4 • USB to UART Bridge DriversS u p er se d e dUSB OTG Capabilities of SmartFusion26.Connect the power supply to the J18 DC jack.Board SetupSnapshots of the SmartFusion2 Development Kit board with the complete set up for both types of connections are given in the following appendices:•"Appendix 1: Board Set up for USB OTG Controller in USB Device Mode" on page 15•"Appendix 2: Board Setup for USB OTG Controller in USB Host Mode" on page 16Table 2 • SmartFusion2 Development Kit Jumper Settings Jumper NumberSettings NotesJ70, J93, J94, J117, J123, J142, J157, J160, J167, J225, J226, J2271-2 closedThese are the default jumper settings of the SmartFusion2 Development Kitboard. Make sure these jumpers are setproperly.J21-3 closedJ23 2-3 closed J129, J1332-3 closed Jumper settings for MMUART_0J110, J118, J119, J1211-2 closed Jumper settings for SPI to SPI-Flashinterface.J139 1-2 closedJumper to select USB resetJ163 1-2 closed Jumper to select USB OTG mode of operation.J1641-2 closedJumper to provide the VBUS supply to USB when using in host mode.S u p er se d e dUSB OTG Capabilities of SmartFusion2 SoC FPGA Devices Demo GuideRunning the Demo Design1.Download the demo design from:/download/rsc/?f=sf2_usb_otg_demo_df.2.Switch ON the SW7 power supply switch.3.Start any serial terminal emulation program such as:–HyperTerminal –PuTTY –Tera Term The configuration for the program is:–Baud Rate: 57600–8 Data bits –1 Stop bit–No Parity –No Flow ControlFor information on configuring the serial terminal emulation programs, refer to the Configuring SerialTerminal Emulation Programs Tutorial .unch the FlashPro software.5.Click New Project .6.In the New Project window, type the project name.7.Click Browse and navigate to the location where you want to save the project.8.Select Single device as the Programming mode .9.Click OK to save the project.10.Click Configure Device on the FlashPro GUI.Figure 5 • FlashPro New ProjectS u p er se d e dUSB OTG Capabilities of SmartFusion211.Click Browse and navigate to the location where the usb_otg_demo.stp file is located and selectthe file. The default location is: <download_folder>sf2_usb_otg_demo_stapl_programming_file . The required programming file is selected and is ready to be programmed in the device.12.Click PROGRAM to start programming the device. Wait until you get a message indicating thatthe program passed. This demo requires the SmartFusion2 device to be preprogrammed with the application code to activate USB OTG functionality. So, the SmartFusion2 device is preprogrammed with the usb_otg_demo.stp using FlashPro software.Figure 6 • FlashPro Project ConfiguredFigure 7 • FlashPro Program PassedS u p er se d e dUSB OTG Capabilities of SmartFusion2 SoC FPGA Devices Demo Guide13.On successfully programming the SmartFusion2 device using FlashPro, the serial terminalemulation program shows the initialization messages as shown in Figure 8. The SmartFusion2USB OTG controller is now set to perform the USB OTG functionality.SmartFusion2 USB OTG Controller Acting as USB Device1.Connect the host PC to micro AB receptacle (P1 connector) provided on the SmartFusion2Development Kit board using the Micro-B to A USB cable.2.Observe a new disk drive/volume in the host PC and properties of this disk drive (right-click thedrive and select properties) as shown in Figure 9 to verify the USB device functionality of the SmartFusion2 USB OTG controller.Note: Format the disk drive when prompted by the host PC and ensure that there is no importantdata on SmartFusion2 Development Kit on-board SPI-Flash.Figure 8 • UART MessageFigure 9 • SmartFusion2 USB Device Detection on Host PC/LaptopS u p er se d e dUSB OTG Capabilities of SmartFusion2SmartFusion2 USB OTG Controller Acting as USB Host1.Unplug the Micro-B to A USB cable from the P1 connector of SmartFusion2 Development Kitboard. 2.Insert the Micro-A to B USB cable with USB mass storage device at the B type end of the cable asshown in Figure 10. Ensure the mass storage device is preformatted.3.Connect the Micro-A end of the Micro-A to B USB cable to the P1 connector of the SmartFusion2Development Kit board. The SmartFusion2 USB OTG controller switches to USB Host mode and detects the connected USB mass storage device to perform transactions as USB host. The application enumerates the USB mass storage device and reads all file names on the USB drive to display the list on serial terminal emulation program as shown in Figure 11.4.To verify the USB OTG functionality again repeat the process of SmartFusion2 USB OTGcontroller acting as USB Device and USB Host.Figure 10 • Micro-A to B USB Cable with Mass Storage at the End BFigure 11 • USB Host Mode ResultsS u p er se d e dUSB OTG Capabilities of SmartFusion2 SoC FPGA Devices Demo GuideAppendix 1: Board Set up for USB OTG Controller in USB Device ModeFigure 12 • Setup for USB OTG Controller in USB Device ModeS u p er se d e dUSB OTG Capabilities of SmartFusion2Appendix 2: Board Setup for USB OTG Controller in USB Host ModeFigure 13 • Setup for USB OTG Controller in USB Host ModeS u p er se d e dUSB OTG Capabilities of SmartFusion2 SoC FPGA Devices Demo Guide Appendix 3: Jumper Locations ArrayFigure14 shows the jumper locations in the SmartFusion2 Development Kit board.Notes:•Jumpers highlighted in red (J2, J23, J70, J93, J94, J117, J123, J142, J157, J160, J167, J225, J226, J227) are set as default.•Jumpers highlighted in green (J110, J118, J119, J121, J129, J133, J139, J163, J164) need to be set manually.•The location of the jumpers in Figure14 are searchable.A – List of ChangesThe following table lists critical changes that were made in each revision of the chapter in the demo guide.Date Changes PageRevision 2(June 2014)Updated the document for Libero v11.3 software release (SAR 58734).NA Revision 1(November 2013)Updated the document for Libero v11.2 software release (SAR 52961).NA Revision 0(October 2013)Initial ReleaseNAS u p er se d e dB – Product SupportMicrosemi SoC Products Group backs its products with various support services, including Customer Service, Customer Technical Support Center, a website, electronic mail, and worldwide sales offices.This appendix contains information about contacting Microsemi SoC Products Group and using these support services.Customer ServiceContact Customer Service for non-technical product support, such as product pricing, product upgrades,update information, order status, and authorization.From North America, call 800.262.1060From the rest of the world, call 650.318.4460Fax, from anywhere in the world, 408.643.6913Customer Technical Support CenterMicrosemi SoC Products Group staffs its Customer Technical Support Center with highly skilled engineers who can help answer your hardware, software, and design questions about Microsemi SoC Products. The Customer Technical Support Center spends a great deal of time creating application notes, answers to common design cycle questions, documentation of known issues, and various FAQs.So, before you contact us, please visit our online resources. It is very likely we have already answered your questions.Technical SupportVisit the Customer Support website (/soc/support/search/default.aspx ) for more information and support. Many answers available on the searchable web resource include diagrams, illustrations, and links to other resources on the website.WebsiteYou can browse a variety of technical and non-technical information on the SoC home page, at /soc .Contacting the Customer Technical Support CenterHighly skilled engineers staff the Technical Support Center. The Technical Support Center can be contacted by email or through the Microsemi SoC Products Group website.EmailYou can communicate your technical questions to our email address and receive answers back by email,fax, or phone. Also, if you have design problems, you can email your design files to receive assistance.We constantly monitor the email account throughout the day. When sending your request to us, please be sure to include your full name, company name, and your contact information for efficient processing of your request.The technical support email address is **********************.S u p er se d e dProduct SupportMy CasesMicrosemi SoC Products Group customers may submit and track technical cases online by going to My Cases .Outside the U.S.Customers needing assistance outside the US time zones can either contact technical support via email (**********************) or contact a local sales office. Sales office listings can be found at /soc/company/contact/default.aspx.ITAR Technical SupportFor technical support on RH and RT FPGAs that are regulated by International Traffic in ArmsRegulations (ITAR), contact us via ***************************. Alternatively, within My Cases , select Yes in the ITAR drop-down list. For a complete list of ITAR-regulated Microsemi FPGAs, visit the I TAR web page.S u p er se d e d50200476-2/06.14© 2014 Microsemi Corporation. All rights reserved. Microsemi and the Microsemi logo are trademarks of Microsemi Corporation. All other trademarks and service marks are the property of their respective owners.Microsemi Corporation (Nasdaq: MSCC) offers a comprehensive portfolio of semiconductor and system solutions for communications, defense and security, aerospace, and industrial markets. Products include high-performance and radiation-hardened analog mixed-signal integrated circuits, FPGAs, SoCs, and ASICs; power management products; timing and synchronization devices and precise time solutions, setting the world's standard for time; voice processing devices; RF solutions; discrete components; security technologies and scalable anti-tamper products; Power-over-Ethernet ICs and midspans; as well as custom design capabilities and services. Microsemi is headquartered in Aliso Viejo, Calif. and has approximately 3,400 employees globally. Learn more at .Microsemi Corporate HeadquartersOne Enterprise, Aliso Viejo CA 92656 USA Within the USA: +1 (949) 380-6100Sales: +1 (949) 380-6136Fax: +1 (949) 215-4996E-mail: ***************************S u p e r s e d e d。

快思聪(crestron)产品各种应用方案

快思聪(crestron)产品各种应用方案

快思聪典型方案CONVERGE目录1、快思聪多媒体电教室中控解决方案 (1)2、快思聪视频会议中控解决方案......................... (5)3、快思聪多功能厅中控解决方案 (11)4、快思聪校园网中控解决方案 (21)快思聪多媒体电教室中控解决方案一、系统概述当今,重视现代教育技术对教育产生的影响,大力推进教育现代化是世界教育发展的主流。

我国在运用现代教育技术手段整合教学的过程中,已取得了相当成效。

采用先进的教学手段,提供全新的教学环境,来设计教学活动,已经成为市场的趋势所在。

随着现代化教学系统在各大院校的不断推进,传统的方式已经不适应现代化的需要,集多功能教室系统、多媒体教学系统、演播系统于一体的新型现代化教育体系在教育行业得到了日益广泛的运用。

作为一种新型的教育形式和现代化教学手段,多媒体技术给教育行业带来了新的机遇。

二、用户需求整个系统要高效率的完成教学任务,结合各个系统,充分发挥各个系统的功能,实现现代化的教学。

(一)多媒体显示系统:多媒体显示系统由高亮度、高分辨率的液晶投影机和电动屏幕构成;完成对各种图文信息的大屏幕显示。

(二)A/V系统:A/V系统由计算机、DVD、VCR(录像机)、实物展台、功放、音箱等A/V设备构成;完成对各种图文信息(包括各种软件的使用、DVD/CD碟片、录像带、各种实物、声音)的播放功能;实现多媒体电教室的现场扩音、播音,配合大屏幕投影系统,提供优良的视听效果。

(三)智能型多媒体中央控制系统:采用目前世界上档次最高、技术最成熟、功能最齐全,用途最广的美国CRESTRON(快思聪)中央控制系统,该系统是目前世界上最先进的中央控制系统设备。

实现多媒体电教室各种电子设备的集中控制。

●要求操作简单、人性化、智能化;●要求整个系统可靠性高;●尽量多的体现出各种设备的卓越功能,让所有设备工作在最佳状态,发挥设备的最大功效;●能够控制投影机,进行开/关机、输入切换等功能;并实现屏幕的上升、停止、下降功能;●能够控制DVD、VCR进行播放、停止、暂停等功能;●能够控制实物展台进行放大、缩小等功能;●能够控制音量,进行音量大小的调节功能;●能够实现音视频、VGA信号自动切换控制功能;(四)设备清单:整个系统的设备清单(含控制方式分析)如下:三、产品清单四、推荐的产品及品牌系统示意图五、功能描述通过安装以上快思聪中央控制系统,能够轻松的实现智能化、人性化的现代化教学:1. 多媒体显示系统的控制:通过主机后的串口(RS232/RS422/RS485埠),控制投影机的所有功能,如开/关机、VIDEO/VGA输入切换等;并且能够自动实现关联动作,如关闭系统时,自动将投影机关闭;STI-1700C - 投影机控制菜单●通过控制投影机的输入切换(VIDEO、VGA 1、VGA 2),实现对视频图像、计算机图像、预留计算机图像的切换;●通过CNPCI-8(8路强电继电器),控制屏幕的上升、下降、停止;并且能够自动实现关联动作,如投影机开时,屏幕自动下降,投影机关时屏幕自动上升。

快思聪系统调试说明 - 硬件 V2

快思聪硬件安装、调试说明:快思聪硬件安装注意事项:●系统安装、调试必须要由经过快思聪培训的专业技术人员完成;●系统安装前,请仔细阅读快思聪产品说明书;●仔细计算所有快思聪设备的总耗电量,确保整个系统的供电充足;否则将导致整个系统工作不正常;●请采用快思聪的电源给所有快思聪设备供电的电源,快思聪的外置电源有:⏹C2N-SPWS300:24VDC,75瓦;⏹CNPWSI-75:24VDC,75瓦;⏹PW-2420RU:24VDC,48瓦;⏹PW-2410RU:24VDC,24瓦;●请采用快思聪专用的Cresnet线材连接快思聪设备;●确保整个系统的接地牢固、可靠;1主机的安装:1.1控制端口的连接1.1.1串口(COM)的连接如上图所示,快思聪主机后面标明有“COM (A-F)”的标准九针串口,可以作为标准的RS232/RS422/RS485端口使用,最高的波特率为115200,最低的波特率为300;请将这些端口根据项目的规划连接到相应受控设备(如投影机、矩阵)的串口;具体的接法如下:当串口作为RS232/RS422端口时:例如:控制EXTRON的RGB矩阵,从其说明书上,查询到如右图的DB-9针脚定义,则可以按照以下表格连接:快思聪串口引脚定义------------- EXTRON引脚定义2(RXD)------------- 2(TXD)3(TXD)------------- 3(RXD)5(GND)------------- 5(GND)当串口作为RS485端口时:快思聪串口引脚定义------------- 第三方设备引脚定义1,9(-)------------- -4,6(+)------------- +5(GND)------------- GND当串口作为RS422端口时:例如:快思聪串口引脚定义------------- 第三方设备引脚定义1(RXD-)------------- TXD-4(TXD+)------------- RXD+5(GND)------------- GND6(RXD+)------------- TXD+9(TXD-) ------------- RXD-1.1.2红外端口(IR)的连接快思聪的红外端口如上图所示,每个红外端口由两个接点组成,分别标明为“S”和“G”;“S”为信号端,“G”为信号地。

Bose Professional Videobar VB-S 2 中文说明书

V I D E O B A R V B‑S请阅读并保留所有安全、安全性和使用说明。

重要安全说明有关 Bose Professional Videobar VB‑S(包括配件和替换件)的更多信息,请参阅/VB-S上的用户指南或联系 Bose Professional 客户服务。

请保留这些说明。

请注意所有警告。

只能使用干布进行清洁。

本产品包含 ¼"–20 UNC 螺纹插件。

如果您使用该插件,应确保其连接的附件能够支撑产品重量,不会发生倾覆或掉落的危险。

有关与本产品配合使用的其他附件和配件的信息,请访问/VB-S。

如果使用推车,则在移动推车/设备时应格外小心,以免因倾倒而造成伤害。

任何维修事宜均请向专业人员咨询。

如果设备有任何损坏(例如电源线或插头受损、液体溅入或物体落入设备内、设备受淋或受潮、不能正常工作或跌落),均需进行维修。

警告/小心此符号表示产品箱体内存在未绝缘的危险电压,可能会造成触电危险。

此符号表示本指南中有重要操作和维护说明。

本产品含有磁性材料。

有关这是否会影响到您的植入式医疗器械,请咨询您的医生。

包含可能导致窒息危险的小部件。

不适合 3 岁以下的儿童使用。

所有 Bose Professional 产品的安装都必须遵守当地、州、联邦和行业规范。

安装人员有责任确保扬声器和安装系统的安装都符合适用的法规,包括当地的建筑法规和规定。

安装本产品前,请咨询拥有司法权的当地监管机构。

放置产品时,确保其不会堵塞您显示屏上的通风口。

请参阅您显示屏的用户指南,并按照制造商的说明进行安装。

未经授权切勿改装本产品。

若需要替换电池,仅可使用 AAA/LR03 碱性电池。

此产品随附的电池如果处理不当、更换不当或更换为不正确的类型,可能存在起火、爆炸或化学灼伤危险。

请勿对其进行充电、拆解、加热或焚烧。

请勿让儿童接触电池。

如果电池漏液,请避免让液体与皮肤或眼睛接触。

如果接触到了液体,请咨询医生。

请勿将含有电池的产品置于过热区域(例如避免阳光直射并远离火源等)。

快思聪ap3说明书

快思聪ap3说明书产品概述:CLX-DIN-AP3提供了一个3系列控制系统,用于与CAEN,CAEN-MLO或CAENIB自动化机柜配合使用。

有两种型号可供选择。

CLX-DIN-AP3包括一个DIN-AP3 3系列自动化处理器和DIN-PWS30-277 30瓦Cresnet电源,预先连接并安装在CAEN-UMP1X2安装板上。

型号CLX-DIN-AP3-HUB包括DIN-AP3和DIN-PWS30-277,并增加了一个DIN-HUB Cresnet分配集线器。

主要特征:•CAEN系列机箱的预接线3系列自动化处理器组件•3系列控制引擎 - 比其他控制系统更快更强大•独家模块化编程架构•预定事件的可编程天文时钟•板载256MB RAM和4GB闪存•存储卡插槽•符合行业标准的以太网和Cresnet®有线通信•带有Smart Graphics™计算机和基于Web的控制XPanel•的iPhone®,iPad®和Android的™控制应用程序支持•CrestronFusion®云企业管理服务支持•SNMP远程管理支持•两个带有硬件和软件握手的RS-232/422/485 COM端口•四个IR /串行,四个继电器和八个Versiport I / O端口•原生BACnet™/ IP支持•通过Crestron Toolbox™软件或网络浏览器安装安装程序•C#,基于符号和拖放式编程环境•完全的统一(多语言)支持•增加网络吞吐量和安全性•通过完整的用户/组管理或Active Directory集成实现安全访问•使用802.1X身份验证的硬件级安全性•TLS,SSL,SSH和SFTP网络安全协议•FIPS 140-2兼容加密•IIS v.6.0 Web服务器•IPv6的准备就绪•前面板USB电脑控制台端口•30瓦通用快思聪网络电源•可选的3段思聪集线器•专为安装在CAEN,CAEN-MLO或CAENIB外壳内而设计品牌:Crestron 是否进口:进口功率:4W 适用范围:家装工装商用酒店餐厅酒吧工作电源:24V DC 使用范围:0-24V可售卖地:全国材质:绝缘硬质塑料外壳类型:控制器型号:DIN-AP3。

ARCHOS VIVID LINQ OBD-II系列说明书(中文版)

SUGGESTED TOOLS NEEDEDn Scissors or clippers (to cut zip ties andor velcro to length) n Glass Cleaner (to improve adhesion to windshield) n Vehicle battery charger (ensures adequate voltage for PCM programming)n Shade (improves your comfort during PCM programming)ARCHOS43 Android Tablet VIVID LINQWindshield Mount 12V Car & 110V Wall ChargersUSB CablesClick on the word “Register” below username and password boxes. REGISTERING THE VIVID LINQwhere you will fill out the required information to gain access to the update server.You will create a unique usernameand password for your securityupdates when needed. Registrantsof the registration page to completeYou are now ready to update yourLOCATING THE MICRO USB PORT ON THE VIVID LINQ Attach the micro USB cable to the the software will automatically be updated. Superchips recommends you update the VIVID LINQ prior to the Some files and options are only presented to the user if the VIVID is vin-locked to your vehicle. If you want to get the full list of options specific to your vehicle (some vehicles have different options than others) it is recommended you install the programming into your vehicle and then log back into Internet Update for a full list of features you can take advantage of. The VIVID software needs to read the vehicle information in order to accurately display available options in Internet Update. All software updates are free. There are additional tuning options available for most applications that theIf at any point you need to update your VIVID LINQ in the future, look on your computers desktop for a quick access point to the Simply double click on the icon to start the connection to the Internet update server. You will be prompted to log in with the username and password you previously created in **One way to speed up the login process is by selecting the “Remember me on this computer” tab at the top right hand Once you’re logged in the VIVID LINQ will start downloading the latest updates. This is an automatic process. Once the software update is complete you will be prompted to “Safely plug the VIVID LINQ into a USB port on your PC.”Use the supplied Micro USBcable supplied in the VIVID boxto connect your ARCHOS unitto your PC. The Micro USB portcable to the ARCHOS unit andthe other end to a USB port onThe enclosed ARCHOS handbook offers instructionsThe windshield mount allows the user ahands free option for ease of tuning orwhile using one of the additional softwarefeatures included in the product. The mountis equipped with a locking suction cup, avertically adjustable arm, and a 360˚ pivothead with spring loaded clips providing asecure grip on the ARCHOS while allowingthe ability to fine tune the viewing angle toFORD OBD-II port located under the driver’s side dashboard(Locations may vary by make/model)USING THE VIVID SOFTWARE Identify the VIVID application icon on the Android desktop. Touch the icon to open the VIVID application. Wait for the connection between the ARCHOS and VIVID LINQ to be made. When the connection has been made a small “blue. Once the two are paired the LED’s on the VIVID LINQ will be idle. You will vehicle application.**In the Large Icon environment users can press the center icon and swipe left or right to view additional icons.Users can switch between views by touching the Grid Icon portion of the screen.The Grid View (Primary View)The Large Icon View**(Secondary)PROGRAMMING YOUR VEHICLEVerify the Bluetooth signal to the VIVID LINQ has been achieved by checking that the LED lights are powered on the VIVID LINQ itself.Next, select the “Tuning” icon to begin tuning your vehicle. You will be prompted with two tuning options: Quick Tuning using Superchips-preferred vehicle settings or Advanced Tuning with user adjustable vehicle settings.A stock vehicle PCM memory read will be performed:QUICK TUNINGThis feature provides the user with predetermined Superchips optimized tuning levels. ADV ANCED TUNINGAllows the user not only the ability to change the power level of your vehicle it also allows you the ability to select all of the options available for your application. **Options may vary by OEM and vehicle type.a series of tuning levels will be a list of user adjustable options will model will be shown detailing tunable options vehicle on the vehicle Select the appropriate options you would like to revise using the touch screen menus. We will use the Speed Limiter option as an example; however, there are numerous options available depending on vehicle application. VIVID will only offer options available for your specific application.**The wireframe image shown will be custom to your application – Truck, Car, or SUV .Select OK to verify your settings and return to the previous screen. You can select another option to adjust other parameters or begin the PCM programming process.To begin programming the vehicle with the setting you selected, click on the Program icon located in the upper right hand corner of the screen.i P lease do not leave the device unattended while tuning the vehicle. You may be required to cycle the ignition switch from the off position to the ignition on [engine off, do not start] position several times during the tuning process.Selecting the Raised value will increase the Speed Limiter to a Superchips set increase in the limit.i D o not start the vehicle at any pointSeveral bars detailing programming percentages as the VIVID installs the files into the vehicles computers.At this point the VIVID has completed its engine and transmission programming. You will now be allowed to explore the additional VIVID options in the app.hen asked to move the key forward do not start the vehicle. SWITCHING TUNING LEVELS OR RETURNING TO STOCKThe diversity of the Superchips VIVIDto change tuning levels and settings asoften as they see fit. For instance, the usermight tow during the week but not on theweekend. The user simply connects tothe tuning software portion of the VIVIDtuning level the same way as describedOnce the vehicle has been tuned by the VIVID, a Stock Tuning Option becomes available. Simply click on the VIVID tuning icon and search forYour vehicle is nowreturned to its originalstock programming.The gauge feature offers users two visual gauges that offer real time sensor datafrom the engine computer. Each gauge can select from a list of sensors that the computer monitors allowing the user to view data specific to their needs in real time. By lightly pressing on an individual gauge the user is offered a number of options including an extensive list of vehicle sensors to monitor, options to change the gauge background including an option to select a customized image for a user has the ability to use the One Touch Tuning feature to return to stock as well as return from stock to the previously tuned program at f the vehicle will be sitting for more than 2-3 days without being started periodically, please unplug the VIVID LINQ from the vehicles data port to prevent voltage drawthe gauge with your finger and dragging it across the screen to the desired position.Select Current: Saves the current image to the gauge being changed. Customize Gauge: Offers background and text color change options. Once done editing touch the large gauge to return to the previous screen.Cancel Gauge ChangesCHANGE MEASUREChange Measure (PID)user with a list of all PID’s applicable to the specific monitored. There are three options available for PID viewing:Allows the user to add PID’s to a favorites section so the user can reference and customize each gauge with that list of favorites. This minimizes scroll time for PID selection. By touching and holding a PID from the list the user is prompted to add toFavorites. The user can also go into the Favorites and remove PID’s the same way.This feature allows you to recordup to 10 driving instances whereyou can select recording optionssuch as 0-30, 0-60, 0-100, ¼Stat bars provide stats for each runselect one of the options from thedrop down menu. Once the Driver isat a complete stop and ready to record, hit the ON button to begin the run.This feature allows you to monitorvehicle data. You may changemonitored information by pressingand holding a graph. You will thenbe taken to a PID selection menuThe list of PID’s shown are for demonstration purposes only and the This feature provides you with additional data. Here is a sample of the different types of information that can be monitored (display will vary by Airflow rate as measured by a mass Calculated air density from the ECU determining the engines air mass flow rate.CHANGING PID MEASURES IN DAQThe three main DAQ features–Power Group, Engine One and Engine Two–have the ability to adjust the diagnostic PID’s to be monitored. By touching and holding an individual graph a list of additional PID’s are provided to customize the gauge.This feature saves the data to a .CSV format on the ARCHOS that you can save a copy to their PC for review at a later date. To record the data the user would go into the specific application to be recorded, select the menu icon then start recording. The user will be prompted to enter the name for the Log.file name by touching the file name box and entering the name with the ARCHOS keyboard. Select the Done Icon to move back.These PID’s may be changed on all engine screens These PID’s may be changed on all engine screensThe Mileage Mentor provides the user with accurate fuel mileage information to help users improve Vehicle odometer. This feature must Distance since the last time you used the Menu item to reset the fuel economy and trip. This is intended to help you identify your mileage based on your last driving “segment.” Your mileage will be considerably different when driving on the city streets versus on a long trip, so they can reset this before going on a trip and then their mileage can be related to the distance shown in the trip box.These values are side by side in this box so you can compare them visually. They are the instant and average values. They will show up as vertical graphs. If the one on the left (Inst) is higher than the one on the right (Ave) then you are doing well. If not, then This is a meter that shows if you are accelerating or decelerating more than you should be.run select menu followed by stop The recording has been saved to the the status icon bar from the top of the ARCHOS screen – USB connected – You will now be prompted with a drive popup on your PC screen. If you do not see a popup dialog in a timely manner you will need to user Windows Explorer to browse to Open the folder in the popup to explore the saved files. Select the Superchips folder followed by the DAQ folder. Find the file you want to save and drag it to the desktop. Once saved to a PC the user can view the file by opening the file using a spread sheetThe Maintenance Minder is anapplication that helps the user keeptrack of when they need to serviceitems is copied to a table in theattaches to. This allows the VIVIDdevice to keep track of the serviceThe need to service the vehicle for an item is determined by the mileage traveled since the last service. This requires the VIVID to be able to track the miles traveled. The LINQ provides a running counter. This counter is not the actual odometer reading of the vehicle. Because of this, the VIVID software allows you to enter the vehicle’s actual odometer value and keeps track of the offset from the actual value to the running counter the LINQ is reporting. From then on, this offset is used to calculate the odometer reading to use throughout the Maintenance Minder.Since the calculation of the free running timer will not always be 100% accurate, an adjustment factor is also created each time you update your vehicle odometer reading in the Maintenance Minder. You can open this dialog and enter the new odometer reading any time. From then on, the calculated adjustment factor is used to adjust the odometer value used by the Maintenance Minder.separated into TWO parts. The first part is the main Maintenance Minder interface application. This application shows the global settings,list of service items, and individual values for the currently selected service item.Notice that the Odometer value on the lower left is 0 and the notification icon on the status bar indicates the Maintenance Minder is not working.At this point you must enter the current vehicle odometer value as shown on theSelecting the menu item shows this screen:When you tap on the edit box it brings up the keyboard and text entry field.You enter the vehicle’s odometer value and hits the DONE button to show the dialogAfter verifying the value entered is correct you hit the OK button.Notice that the All Items check button is off which also causes the notification icon to show the Maintenance Minder is off.Tapping the “ON” button in the All Items check box causes the notification to turnTapping on one of the service items in the list causes the fields on the right side of theAs long as the Service Interval is 0that item is effectively not active eventhough the check button shows it tobe active. To make an item actuallyanInterval must be entered. This is doneby tapping on the Service Interval editbox which brings up the keyboard andEnter the Interval value and hit the DONE button on the lower right side of the display.If the Service Interval is such that the current odometer plus the Service Threshold (lower left) is greater than or equal to the Next Service value then the item is considered to be getting close to being due. This causes a notification warning. The warning is indicated by the Service Item being yellow in the list and the notification icon showing that there are items coming due soon.You can change the Service Threshold by tapping on the edit box in the lower leftcorner. This brings up the keyboard and text entry dialog shown here:Nothing else changed because the Service Threshold was past the service item already. If there are any Service Items that the odometer value is greater than the Next Service value without having to add in the Threshold, the item is considered past due and not coming due. This causes an Urgent Item condition as shown in this screen:Notice the notification icon now shows an Urgent Item condition. The Urgent Item condition takes precedence over the warning condition.If you drag down the notification from the notification bar, you will see text similar toIf there are no items due, the icon willbe green and the text will say “NoItems Due.” If there are only warningitems the icon will be yellow and thetext will say Items coming due duringthreshold period: x, where x is thenumber of items that are coming due.If there are only urgent items, the iconwill be red and the text will say Itemsdue now: x, where x is the number ofitems that are past due.If there are both warning and urgent items, the icon will be red and both text will be shown along with the count of each type of item coming due.If you tap on the notification area while it is open, you will be taken to the Maintenance Minder application no matter what application you were in before.Note: Increasing the threshold will cause items to show a warning sooner.CALIBRATEThis feature set’s the gauges current position to zero to make sure the gauges are accurate at the time of use.i U se this option once the VIVID is mounted to the windshield and the vehicle is on flat land.This feature provides you with a large group of additional gauge images. You at the bottom of the screen to scrollthrough all of the image selections.This feature reads and clearsDiagnostic Trouble Codes**. If atrouble code exists the user will bethe vehicle, clear the existing codes,collapse the data, expand the data anda device list option which is used to pair the ARCHOS device to the VIVID LINQ. **Some codes are hard codes, i.e. when a part is missing or broken. Even if you clear the codes, a CEL will still be illuminated and the DTC will remain until the problem is fixed, or the vehicles PCM is reflashed (if the part is not fixed the DTC will come back). Other codes like P1000 remain until the vehicle has completed a certain amount of trip cycles and the adaptive info has been learned.The P1000 code tells emission testers that the vehicle has recently been cleared and is ineligible for emissions testing. When preparing for an emissions test, make sure you have several miles of drive time logged in the vehicle and have not recentlycleared any trouble codes so that the P1000 code clears.TROUBLESHOOTINGWhen a LINQ is in recovery state the ARCHOS/VIVID will prompt you to enter Recovery Mode which will follow a step-by-step process to return the vehicle to stock. This could be caused by stock due to an error during the tuning process (Ignition on not detected, Disconnection of the LINQ from the data port during tuning, A lowWhen the LINQ is in a recovery state it will not allow the user to complete anyIn the event the vehicle does not start after tuning, and the LINQ is not prompting the user to enter recovery mode, you will need to enter the tuning app and explicitly return the vehicle to stock. You should not use the One Touch Tuning app to do this since it will save the current settings.If your ARCHOS experiences a general error or an endless pause at any point, you need to reset the VIVID application by first returning the ARCHOS unit to the homescreen or VIVID launcher, then removing and reinserting the LINQ from the data port.Follow Us1790 East Airport Blvd. | Sanford, FL 32773 | 888.227.2447Rev. 01。