0mmh0=720mm Y向轴力点=Fk2*cy/(Fk1+Fk2)=0mm(双柱)柱根宽度bc600mm X向轴力偏心距ex0=0mm(双柱)柱根长度hc600mm Y向轴力偏心距ey0=0mmFk=2540.00kN fc=11.9N/mm^2竖向力F=γz*Fk=3429.00kN ft= 1.27N/mm^2 fa=fak+ηb*γ*(b-3)+ηd*γm*(d-0.5)=240kpa轴心受压基底面积=(Fk+Gk)/(fa-γg*ds)12.70M^2(注:γg取20.0kN/M^3)计算基础长度b=3564mm 取基础长度b=计算基础宽度L=3564mm 取基础宽度L=Mx=γz*{(Mkx1'+Mkx2')-(Vky1+Vky2)*H+Fk*ey0}=-55.4kN·MMy=γz*{(Mky1'+Mky2')+(Vkx1+Vky2)*H+Fk*ex0}=-50.2kN·MY 轴方向截面面积 Acb 2.3M^2X 轴方向截面面积 AcL 2.3M^2X轴基础顶面坡度15.42°Y轴基础顶面坡度15.42°基础底面积A12.96M^2X向Wx=l * b * b / 67.78M^3Y向Wy = b * l * l / 67.78M^3基础及土自重标准值Gk=γg*A*ds=518.40kN基础及的土重设计值G=γz*Gk=699.84kN轴心荷载作用下pk = (Fk+ Gk) / A235.99<fa=240.0kpa通过X向pkmaxX=(Fk+Gk)/A+|Mky|/Wx=240.77< 1.2*fa=288.0kpa通过X向pkminX=(Fk+Gk)/A-|Mky|/Wx=231.20>0.00kpa >0可以X向偏心矩ex=Mky/(Fk+Gk)=-0.012<b/6=0.60mY向pkmaxY=(Fk+Gk)/A+|Mkx|/Wy=241.26< 1.2*fa=288.0kpa通过Y向pkminY=(Fk+Gk)/A-|Mkx|/Wy=230.72>0.00kpa >0可以Y向偏心矩ey=Mkx/(Fk+Gk)=-0.013<L/6=0.600mpmaxX=γz*PkmaxX=325.04kpa pjmaxX=pmaxX-G/A=271.0kpapmaxY=γz*PkmaxY=325.70kpa pjmaxY=pmaxY-G/A=271.7kpaX方向冲切验算因b - hc=3000=L - bc=3000mmb=3600>hc+2*Ho=2040mmL=3600>b c+2*Ho=2040mm Alx=0.5*(b-hc+2*bc+2*Ho)*[(b-hc)/2-Ho]=2199600mm^2 ab = Min{bc + 2 *Ho,l} =2040mmamx = (bc + ab) / 2=1320mm0.7 * βhp * ft * amx* Ho =760.42>Flx=pjmaxX*Alx=596.18通过Y方向冲切验算Aly=0.5*(l-bc+2*hc+2*Ho)*[(l-bc)/2-Ho]=2199600m m^2 ab = Min{hc + 2 *Ho,b}2040mmamy = (hc + ab) / 21320mm0.7 * βhp * ft * amY* Ho =760.42>Fly=pjmaxY*Aly=597.63通过X 方向(b 方向)剪切验算计算宽度Lo={1.0-0.5*[1.0-(bc+2*50)/L]*(Ho-h1)/Ho}*L=2955.56mmVx=pj*Ax=pj*(b-hc)*L/2=1463.63<0.7*βh*ft*Lo*Ho=1891.79通过Y 方向(l 方向)剪切验算计算宽度bo={1.0-0.5*[1.0-(hc+2*50)/b]*(Ho-h1)/Ho}*b=2955.56mmVy=pj*Ay=pj*(l-bc)*b/2=1463.63<0.7*βh*ft*bo*Ho=1891.79通过X 方向(b 方向)柱边(绕 Y 轴)抗弯计算pmaxX=γz*PkmaxX=325.04kpapminX=γz*PkminX=312.13kpapX=pminX+(pmaxX-pminX)*(b+hc)/b/2=319.66kpaMIx=(b-hc)^2*[(2*L+bc)*(pmaxX+pX-2*G/A)+(pmaxX-pX)*L]/48=788.6kN·M MⅡx=(L-bc)^2*(2*b+hc)*(pmaxX+pminX-2*G/A)/48=773.9kN·M Y 方向(l 方向)柱边(绕 X 轴)抗弯计算pmaxY=γz*PkmaxY=325.70kpapminY=γz*PkminY=311.47kpapY=pminY+(pmaxY-pminY)*(L+bc)/L/2=319.77kpaMIy=(b-hc)^2*[(2*L+bc)*(pmaxY+pY-2*G/A)+(pmaxY-pY)*L]/48=790.1kN·M MⅡy=(L-bc)^2*(2*b+hc)*(pmaxY+pminY-2*G/A)/48=773.9kN·M MⅠ= Max{MⅠx,MⅡy} =788.56kN·MAsⅠ=MⅠ/0.9*h0*fy*L=1127mm^2/MΦ12@100 MⅡ= Max{MⅡx,MⅠy} =790.06kN·MAsⅡ=MⅡ/0.9*h0*fy*B=1129mm^2/MΦ12@100柱下局部受压承载力计算混凝土局部受压面积 Al= bc * hc =360000mm^2Ab = (bx + 2 * c) *(by + 2 * c)=490000mm^2βl = Sqr(Ab / Al)= 1.171.35 * βc * βl * fc *Al =6747.30> F =3429.0kN通过注意:轴心荷载pk通过X向pkmaxX通过X向pkminX>0可以Y向pkmaxY通过Y向pkminY>0可以X方向冲切验算通过Y方向冲切验算通过X方向剪切验算通过Y方向剪切验算通过柱下局部受压通过AsI=1127mm^2/M AsⅡ=1129mm^2/MΦ12@100Φ12@100中间结果Alx=0.5*(L+bc+2*Ho)*(L-bc-2*Ho)/2+L*(b-hc-L+bc)/2=2199600 Alx=L*[0.5*(b-hc)-h0]=2808000 Alx=0.5*(b-hc+2*bc+2*Ho)*[(b-hc)/2-Ho]=2199600 Aly=0.5*(b+hc+2*Ho)*(b-hc-2*Ho)/2+b*(L-bc-b+hc)/2=2199600 Aly=b*[0.5*(L-bc)-h0]=2808000 Aly=0.5*(l-bc+2*hc+2*Ho)*[(l-bc)/2-Ho]=2199600。

独立基础计算书

独立基础计算书

####### 0.00 17.40 16.90 500.00 500.00 1.00 C25 300 C25
11.9 164.10 160.00
9.61 4.97 4.97 9.61 164.09 169.21 158.97 满足 满足
167.68 0.44 392.6 满足 0.44 392.6 满足
满足, 满足,不用验算柱下扩展基础顶面的局部受压承载力
pS=F/A (KN/m2) M1=ps(B-bc)2(2L+hC)/24 (KN·m) AS1=M1/(0.9fyLh0) (mm2) M2=pS(L-hc)2(2B+bC)/24 (KN·m) AS2=M2/(0.9fyBh0) (mm2) ASmin=0.15%h*1000 (mm2) 长边选用钢筋直径 d (mm) 14 钢筋间距s (mm) 180 855.21 长边实配钢筋 (mm2) 满足 长边是否满足
面的局部受压承载力
160.77 303.40 788.01 303.40 788.01 750.00 14 180 855.21 满足
数据输入
120.00 0.3 1.4 20.00 18.00 2.60 2.25 承载力修正用基础埋置深度d' (m)【自室内地面算起】 2.25 基础高度 h (mm) 500 基础边缘高度 h1 (mm) 250 地基承载力特征值 fak 基础宽度修正系数 η b 基础深度修正系数 η d 基础底面以下土的重度 γ (KN/m3) 基础底面以上土的重度 γ m (KN/m3) 基础底面宽度 b (m) 计算Gk用的基础平均埋置深度 d (m) 一层柱底荷载设计值 N (KN) 一层墙体荷载设计值 Nq (KN) 基底短边方向力矩设计值MB (KN·m) 基底长边方向力矩设计值ML (KN·m) 柱沿基础短边方向尺寸 bC (mm) 柱沿基础长边方向尺寸 hC (mm) 基础长短边尺寸比 L/B 混凝土强度等级 受力钢筋强度设计值 fy (N/mm2) 柱子的强度等级

独立基础计算书(审图用)

独立基础计算书(审图用)
2
270.0 1.6 19.0 21.0 2.2 6.0 4.0 600.0 300.0
J-1 一层柱底荷载设计值N (KN) 1295.0 一层墙体荷载设计值Nq (KN) 0.0 基底短边方向力矩设计值MB (KN·m) 0.0 基底长边方向力矩设计值ML (KN·m) 10.0 柱沿基础短边方向尺寸bC (mm) 400.0 柱沿基础长边方向尺寸hC (mm) 500.0 基础长短边尺寸比L/B 1.2 混凝土强度等级 C25 2 300.0 受力钢筋强度设计值fy (N/mm )
2.0 0.0 0.0 0.0 0.0
深度修正系数η dZ 地基压力扩散角θ 1 (°) 深度修正系数η dZ 地基压力扩散角θ 2 (°) 深度修正系数η dZ 地基压力扩散角θ 3 (°)
0.0 1.0 0.0 1.0 0.0
数据输出
一、常规数据 1.3 混凝土抗拉设计值ft (N/mm2) 混凝土轴心抗压设计值fc (N/mm2) 地基承载力设计值f0=fk+η bγ (b-3)+η dγ 0(d'-0.5) (KN/m2) 地基承载力设计值取值f=MAX(f0,1.1fk) (KN/m2) 11.9 387.6 380.0
三、抗冲切验算 231.2 基础底面净反力最大值pSmax=pmax-20d (KN/m2) 2 基础有效高度h0=h-40 (mm) 560.0 抗冲切面积At=(2bC+2hC+4h0)h0 (m ) 2.3 2 抗冲切力Ft=0.6ftAt (KN) 3.3 1723.9 冲切面积Al=A-B(hC+2h0) (m ) 验算 Fl≤ Ft 冲切力Fl=pSmaxAl (KN) 753.0 满足 四、抗剪切验算 抗剪切面积AV=Bh0-(h-h1)(B-bC)/2 (m2) 1.0 抗剪切力0.07fcAV (KN) 801.3

独立基础加固计算书

独立基础加固计算书

独立基础加固计算书
一、引言
独立基础作为建筑物的主要承重结构,其安全性至关重要。

然而,由于各种原因,有时需要对独立基础进行加固。

本计算书旨在为独立基础加固提供理论依据和计算方法,以确保加固后的基础能够满足安全性和稳定性要求。

二、独立基础加固计算
1. 承载能力计算
首先,我们需要计算独立基础的承载能力。

根据相关规范和标准,基础承载能力应满足以下公式:
P≤βcfc×A
其中,P为基础承载能力设计值,βc为基础承载能力调整系数,fc为基础混凝土抗压强度设计值,A为基础底面积。

如果原有基础的承载能力不足,可以通过增加基础底面积、提高混凝土强度等级或增加配筋等方式进行加固。

2. 抗滑稳定性计算
抗滑稳定性是确保基础不发生滑移的重要因素。

根据相关规范和标准,基础抗滑稳定性应满足以下公式:
K≤R/F
其中,K为基础抗滑稳定性系数,R为基础水平阻力,F为基础底面摩擦力。

如果原有基础的抗滑稳定性不足,可以通过增加基础埋深、增加基础侧面摩擦力或增加配筋等方式进行加固。

三、加固方法及适用范围
1. 扩大基础底面积
当原有基础承载能力不足时,可采用扩大基础底面积的方法进行加固。

该方法适用于各种土质条件,且施工简单、成本低廉。

2. 增加配筋
当原有基础承载能力或抗滑稳定性不足时,可采用增加配筋的方法进行加固。

该方法适用于混凝土基础,可有效提高基础的受力性能和抗剪切能力。

独立柱基计算书

独立柱基计算书

独立柱基计算书项目名称_____________日期______设计者_____________校对者_____________一、基础类型及计算形式平面:剖面:基础类型:锥型柱基计算形式:验算截面尺寸已知尺寸:B1 = 600(mm), W1 = 1050(mm)H1 = 450(mm), H2 = 0(mm)B = 460(mm), H = 540(mm)无偏心:B2 = 600(mm), W2 = 1050(mm) 二、几何数据及材料特性混凝土:C25 钢筋:二级(d<=25) 三、荷载数据竖向荷载F = 83.00kN自重土重G = 68.04kNMx = 45.00kN*mMy = 0.00kN*m四、地基承载力设计值计算公式:《建筑地基基础设计规范》(GB50007-2002)f = fak +ηb*γ*(b-3) +ηd*γm*(d-0.5) (式5.2.4)式中:fak = 240.00 kPaηb = 0.30,ηd = 1.60γ = 18.00 kN/m3γm = 18.00 kN/m3b = 2.10 m,d = 1.50 m如果b <3m,按b = 3m, 如果b > 6m,按b = 6m如果d <0.5m,按d = 0.5mf = fak +ηb*γ*(b-3) +ηd*γm*(d-0.5)= 240.00 + 0.30*18.00*( 3.00-3.00) + 1.60*18.00*( 1.50-0.50)= 268.80 kPa地基承载力设计值f = 268.80 kPa五、轴心荷载作用下地基承载力验算p = (F+G)/A其中:A = 2.10 * 1.20 = 2.52 m2p = ( 83.00 +68.04 ) / 2.52 = 59.94 kPa ≤f,, 满足要求计算公式:pmax=(F+G)/A+M/Wpmin=(F+G)/A-M/WY方向(b方向):Mx = 45.00kN*m偏心矩ey = Mx/(F+G)= 45.00/(83.00 + 68.04)= 0.30 m≤b/6 = 2.10/6 = 0.35 m偏心矩ey, 满足要求基础底面抵抗矩Wy = a * b * b / 6= 1.20 * 2.10 * 2.10 / 6= 0.88m3P maxY = ( 83.00 + 68.04 ) / 2.52 + 45.00 / 0.88= 110.96 kPa≤1.2 * f = 1.2 * 268.80 = 322.56 kPa,, 满足要求P minY = ( 83.00 + 68.04 ) / 2.52 - 45.00 / 0.88= 8.92 kPa≥0, 满足要求。

独立基础计算步骤

独立基础计算步骤

独立基础计算步骤
独立基础是一种基础结构,其计算步骤如下:
1. 根据表1-9查到钢筋单位理论质量;
2. 根据表1-13查到钢筋保护层厚度;
3. 根据图示集中标注找到底板钢筋尺寸及此基础分底板的边长;
4. 计算x向底板钢筋和y向底板钢筋的质量。

x方向钢筋根数=(基础底板的宽-0.04*2)/0.20+1,x方向钢筋质量=(基础底板的宽*2+基础底板的宽*90%*30)*1.208*3。

同理,可求出y方向钢筋质量;
5. 根据图示集中标注找到顶部钢筋配置及顶部基础边长;
6. 求横向分布钢筋质量。

钢筋根数=(基础顶板的宽-0.02*2)/0.20+1,钢筋质量=(2.35+12.5*0.01-0.02*2)*23*0.617*3。

同理,可求出纵向受力钢筋质量;
7. 底板x方向钢筋质量+底板y方向钢筋质量+顶部分布钢筋质量+顶部纵向受力钢筋质量=独立基础钢筋工程量。

独立基础的计算需要考虑许多因素,如基础尺寸、钢筋配置、混凝土强度等。

在进行计算时,建议仔细阅读相关规范和设计图纸,确保计算结果的准确性。

如有需要,可以咨询专业的结构工程师或建筑师。

独立基础设计计算书

独立基础设计计算书

目录1 基本条件的确定 (2)2 确定基础埋深 (2)2.1设计冻深 (2)2.2选择基础埋深 (2)3 确定基础类型及材料 (2)4 确定基础底面尺寸 (2)4.1确定B柱基底尺寸 (2)4.2确定C柱基底尺寸 (3)5 软弱下卧层验算 (3)5.1 B柱软弱下卧层验算 (3)5.2 C柱软弱下卧层验算 (4)6 计算柱基础沉降 (4)6.1计算B柱基础沉降 (4)6.2计算C柱基础沉降 (6)7 按允许沉降量调整基底尺寸 (7)8 基础高度验算 (8)8.1 B柱基础高度验算 (9)8.2 C柱基础高度验算 (10)9 配筋计算 (12)9.1 B柱配筋计算 (12)9.2 C柱配筋计算 (14)1 基本条件确定人工填土不能作为持力层,选用亚粘土作为持力层。

2 确定基础埋深2.1设计冻深⋅⋅⋅Z =Z zw zs o d ψψze ψ=2.01.000.950.90⨯⨯⨯1.71=m2.2选择基础埋深根据设计任务书中给出的数据,人工填土d 1.5m =,因持力层应选在亚粘土层处,故取0m .2d =3 确定基础类型及材料基础类型为:柱下独立基础基础材料:混凝土采用C25,钢筋采用HPB235。

4 确定基础底面尺寸根据亚粘土e=0.95,l I 0.65=,查表得0, 1.0b d ηη==。

因d=2.0m 。

基础底面以上土的加权平均重度:1[18.0 1.519.0(2.0 1.5)]/2.018.25o γ=⨯+⨯-=3/m KN 地基承载力特征值a f (先不考虑对基础宽度进行修正):11(0.5)150 1.018.25(2.00.5)177.38a a d m f f d ηγ=+⋅-=+⨯⨯-=a KP 4.1 确定B 柱基底尺寸20240017.47.177.3820 2.0K a G F A m f d γ≥==--⨯由于偏心力矩不大,基础底面面积按20%增大,即A=1.20A =20.962m 。

独立基础计算书..

独立基础计算书..

独立基础计算书计算依据:1、《建筑地基基础设计规范》GB50007-20112、《混凝土结构设计规范》GB50010-20103、《建筑结构荷载规范》GB50009-2012一、基本参数1、上部荷载参数基础顶部柱子轴力设计值F(kN) 200 基础顶部柱子弯矩设计值Mx(kN·m) 50基础顶部柱子弯矩设计值My(kN·m) 50 基础顶部柱子剪力设计值Vx(kN) 10基础顶部柱子剪力设计值Vy(kN) 10 标准组合分项系数Ks 1.3基本组合分项系数Kc 1.352、基础上部柱子参数基础上部柱子截面类型方柱砼柱截面长a(mm) 800砼柱截面宽b(mm) 6003、基础参数基础类型阶梯形基础台阶数三阶基础底面长L×宽B×高h1(mm) 3600×2800×400 基础二阶底面长L1×宽B1×高h2(mm) 2800×2000×400 基础柱边面长dx×宽dy×高h3(mm) 600×300×400 基础埋置深度H1(m) 2.4混凝土强度等级C30 基础自重γc(kN/m3) 24基础上部覆土厚度h′(m) 1.2 基础上部覆土的自重γ′(kN/m3)17基础混凝土保护层厚度δ(mm)504、地基参数地基承载力特征值fak(kPa) 170 基础宽度地基承载力修正系数ηb0.3基础埋深地基承载力修正系数ηd 1.6 基础底面以下的土的重度γ(kN/m3)20基础底面以上的土的加权平均重度γm(kN/m3)18 基础底面修正后的地基承载力特征值fa(kPa)224.725、软弱下卧层基础底面至软弱下卧层顶部的距离2 地基压力扩散角θ(°)23 z(m)软弱下卧层顶处修正后的地基承载力160设计值faz(kPa)二、计算简图平面图剖面图1-1剖面图2-2三、承台验算1、基础受力设计值计算:F=200KNM x′=M x+H1×V x=50+2.4×10=74kN·mM y′=M y+H1×V y=50+2.4×10=74kN·m标准值计算:(标准组合)F k=K s×F=1.3×200=260kNM xk=K s×M x′=1.3×74=96.2kN·mM yk=K s×M y′=1.3×74=96.2kN·m2、基础及其上土的自重荷载标准值:G k =L ×B ×(γc ×h 1+ (h ′+h 2+h 3) ×γ′)+L 1×B 1×h 2×(γc -γ′)+(d x ×2+a ) ×(d y ×2+b)×h 3×(γc -γ′)=3.6×2.8×(24×0.4+ (1.2+0.4+0.4)×17)+2.8×2×0.4×(24-17)+(0.6×2+0.8 ) ×(0.3×2+0.6)×0.4×(24-17)=461.888kN 3、基础底面压应力计算p k = (F k + G k )/A=(260+461.888)/(2.8×3.6)=71.616kPa 基础底面抵抗矩:W X = BL 2/6=2.8×3.62/6=6.048m 3 基础底面抵抗矩:W Y = LB 2/6=3.6×2.82/6=4.704m 3e x =M xk /(F k +G k )=96.2/(260+461.888)=0.133p xkmax = (F k + G k )/A + |M xk |/W x =71.616+96.2/6.048=87.522kPa p xkmin = (F k + G k )/A - |M xk |/W x =71.616-96.2/6.048=55.71kPa p x 增= p xkmax -p k =15.906kPa p x 减= p k -p xkmin =15.906kPae y =M yk /(F k +G k )=96.2/(260+461.888)=0.133p ykmax = (F k + G k )/A + |M yk |/W y =71.616+96.2/4.704=92.067kPa p ykmin = (F k + G k )/A - |M yk |/W y =71.616-96.2/4.704=51.165kPa p y 增= p ykmax -p k =20.451kPa p y 减= p k -p ykmin =20.451kPap kmax = p k + p x 增+ p y 增=71.616+15.906+20.451=107.973kPa p kmin = p k - p x 减- p y 减=71.616-15.906-20.451=35.259kPa基座反力图1)轴心作用时地基承载力验算P k=71.616kPa≤fa=224.72kPa满足要求!2)偏心作用时地基承载力验算P kmax=107.973kPa≤1.2f a=1.2×224.72=269.664kPa满足要求!4、软弱下卧层验算基础底面处土的自重压力值:p c= H1×γm=2.4×18=43.2kPa下卧层顶面处附加压力值:p z=l b-43.2)/((2.8+2×2×tan23)×(3.6+2×2×(p kmax-p c)/((b+2ztanθ)(l+2ztanθ))=3.6×2.8×(107.973×tan23))=27.399kPa软弱下卧层顶面处土的自重压力值:p cz=z×γ=2×20=40kPa作用在软弱下卧层顶面处总压力:p z+p cz=27.399+40=67.399kPa≤faz=160kPa满足要求!5、基础抗剪切验算2.8))=83.904kPa(107.973-461.888/(3.6×P jmax= K c×(p kmax-G k /A) =1.35×P jmin=0kPa1)第一阶验算抗剪切计算简图一阶X向抗剪切计算简图一阶y向h0x=h1-(δ+φx/2) = 400-(50+10/2)=345mmβhx=(800/ h0x)0.25=1A cx1= Lh0x=3600×345=1242000 mm2V x=0.7×βhx×f t×A cx1=0.7×1×1.43×1242000=1243242N=1243.242kN≥pjmax3.6×(2.8-2)/2=120.822kN×L×(B-B1 )/2=83.904×h0y=h1-(δ+φy /2)= 400-(50+10/2)=345mmβhy=(800/h0y)0.25=1A cy1=Bh0y= 600×345=207000 mm2V y=0.7×βjmax×B×(L- hy×f t×A cy1=0.7×1×1.43×207000=207207N=207.207kN≥pL1 )/2=83.904×2.8×(3.6-2.8)/2=93.972 kN满足要求!2)第二阶验算抗剪切计算简图二阶X向抗剪切计算简图二阶y向h0x=h1-(δ+φx/2)+ h2 =400-(50+10/2)+400=745mmβhx=(800/h0x)0.25=1400=2362000 mm2A cx2 =L×(h0x-h2) + L1×h2=3600×(745-400)+2800×V x=0.7×βjmax×L×(B-(b+2d y hx×f t×A cx2=0.7×1×1.43×2362000=2364362N=2364.362kN≥p3.6×(2.8-0.6-2×0.3)/2=241.644 kN))/2=83.904×h0y=h1-(δ+φy/2)+ h2 =400-(50+10/2)+400=745mmβhy=(800/h0y)0.25=1400=1766000 mm2A cy2 =B×(h0y-h2) + B1×h2=2800×(745-400)+2000×V y=0.7×βhy×f t×A cy2=0.7×1×1.43×1766000=1767766N=1767.766kN≥pjmax×B×(L-(a+2d x0.6)/2=187.945 kN))/2=83.904×2.8×(3.6-0.8-2×满足要求!3)第三阶验算抗剪切计算简图三阶X向抗剪切计算简图三阶y向h0x=h1-(δ+φx/2) + h2+ h3=400-(50+10/2)+400+400=1145mmβhx=(800/h0x)0.25=0.914400+(800+2×600)×A cx3=L×(h0x-h2-h3)+L1×h2+(a+2d x)×h3=3600×(1145-400-400)+2800×400=3162000 mm2V x=0.7×βhx×f t×A cx3=0.7×0.914×1.43×3162000=2892958.068N=2892.958kN≥pjmax3.6×(2.8-0.6)/2=332.26kN×L×(B-b)/2=83.904×h0y=h1-(δ+φy/2) + h2+ h3= 400-(50+10/2)+400+400=1145mmβhy=(800/h0y)0.25=0.914400+(600+2×300)A cy3=B×(h0y-h2-h3)+B1×h2+(b+2d y)×h3=2800×(1145-400-400)+2000××400=2246000 mm2V y=0.7×βjmax hy×f t×A cy3=0.7×0.914×1.43×2246000=2054896.844N=2054.897kN≥p×B×(L-a)/2=83.904×2.8×(3.6-0.8)/2=328.904kN满足要求!6、基础抗冲切验算1)第一阶验算k=(L1 -B1 )/2=(2800-2000)/2=400mmX方向验算:抗冲切验算一阶X向a bx=2h0x +L1=2×345+2800=3490 mm≤L=3600mm,取a bx=2h0x+L1=3490 mmy1= L/2-k=3600/2-400 =1400 mm≥B/2=1400 mm(2800/2+400) =3600 mmx1=2×(B/2+k) =2×y2=h0x +B1/2=345+2000/2 =1345 mmA lx=(B/2-y2)(a bx+x1)/2 = (2800/2-1345)( 3490+3600)/2=194975 mm2Y方向验算:抗冲切验算一阶y向a by=2h0y+B1=2×345+2000=2690mm≤B=2800mm,取a by=2h0y+B1=2690mmx1= B/2+k= 2800/2+400=1800 mm≥3600/2=1800 mm(3600/2-400)=2800 mmy1=2×(L/2-k) =2×x2= h0y +L1/2=345+2800/2=1745mmA ly= (L/2-x2)(a by+y1)/2 = (3600/2-1745)(2690+2800)/2=150975mm2a mx=(a t +a bx)/2=(2800+3490)/2=3145mma my=(a t +a by)/2 =(2000+2690)/2=2345mmA q1x=a mx×h0x=3145×345=1085025 mm2A q1y=a my×h0y=2345×345=809025 mm2F lx=0.7×βjmax hp×f t×A q1x=0.7×1×1.43×1085025=1086110.025N=1086.11kN≥p×A lx=83.904×0.001×194975=16359.182N=16.359kNF1y=0.7×βjmaxhp×f t×A q1y=0.7×1×1.43×809025=809834.025N=809.834kN≥p×A ly=83.904×0.001×150975=12667.406N=12.667kN满足要求!2)第二阶验算300))/2=400mm600)-(600+2×k=((a+2d x) -(b+2d y) )/2=((800+2×X方向验算:抗冲切验算二阶X向,取a bx=2h0x +(a+2d x)=2×745+(800+2×600)=3490 mm≤L=3600mm a bx=2h0x+(a+2d x)=3490 mmy1= L/2-k=3600/2-400 =1400 mm≥B/2=1400 mm(2800/2+400) =3600 mmx1=2×(B/2+k) =2×300)/2 =1345 mmy2=h0x +(b+2d y)/2=745+(600+2×A lx=(B/2-y2)(a bx+x1)/2 = (2800/2-1345)( 3490+3600)/2=194975 mm2Y方向验算:抗冲切验算二阶y向,取a by=2h0y+(b+2d y)=2×745+(600+2×300)=2690mm≤B=2800mma by=2h0y+(b+2d y)=2690mmx1= B/2+k= 2800/2+400=1800 mm≥3600/2=1800 mmy1=2×(L/2-k) =2×(3600/2-400)=2800 mm600)/2=1745mmx2= h0y +(a+2d x)/2=745+(800+2×A ly= (L/2-x2)(a by+y1)/2 = (3600/2-1745)(2690+2800)/2=150975mm2a mx=(a t +a bx)/2=(2000+3490)/2=2745mma my=(a t +a by)/2 =(1200+2690)/2=1945mmA q1x=a mx×h0x=2745×745=2045025 mm2A q1y=a my×h0y=1945×745=1449025 mm2F lx=0.7×βjmax hp×f t×A q1x=0.7×1×1.43×2045025=2047070.025N=2047.07kN≥p×A lx=83.904×0.001×194975=16359.182N=16.359kNF1y=0.7×βhp×f t×A q1y=0.7×1×1.43×1449025=1450474.025N=1450.474kN≥pjmax×A ly=83.904×0.001×150975=12667.406N=12.667kN满足要求!3)第三阶验算k=(a -b )/2=(800-600)/2=100mmX方向验算:抗冲切验算三阶X向a bx=2h0x+a=2×1145+800=3090 mm≤L=3600mm,取a bx=2h0x+a=3090 mm y1= L/2-k=3600/2-100 =1700 mm≥B/2=1400 mm(2800/2+100) =3000 mmx1=2×(B/2+k) =2×y2=h0x +b/2=1145+600/2 =1445 mmA lx=(B/2-y2)(a bx+x1)/2 = (2800/2-1445)( 3090+3000)/2=-137025 mm2因为A lx<0,即A lx不存在,故取A lx=0Y方向验算:抗冲切验算三阶y向a by=2h0y+b=2×1145+600=2890mm> B=2800mm,取a by=B=2800mmx2= h0y +a/2= 1145 +800/2=1545mm2800=714000mm2A ly= (L /2- x2) ×a by= (3600 /2- 1545) ×a mx=(a t +a bx)/2=(800+3090)/2=1945mma my=(a t +a by)/2 =(600+2800)/2=1700mmA q1x=a mx×h0x=1945×1145=2227025 mm2A q1y=a my×h0y=1700×1145=1946500 mm2F lx=0.7×βjmax hp×f t×A q1x=0.7×0.914×1.43×2227025=2037536.351N=2037.536kN≥p×A lx=83.904×0.001×0=0N=0kNF1y=0.7×βjmaxhp×f t×A q1y=0.7×0.914×1.43×1946500=1780880.101N=1780.88kN≥p×A ly=83.904×0.001×714000=59907.456N=59.907kN满足要求!四、承台配筋计算承台底部X轴向配筋HRB335Ф10@120承台底部Y轴向配筋HRB335Ф10@110基础底板受力配筋图2.8))=34.822kPaP j= K c×(p k-G k /A) =1.35×(71.616-461.888/(3.6×1)第一阶验算M1x=1/48[(p jmax+ p j) ×(2L+ L1)+ (p jmak-p j) ×L] ×(B -B1)2 =1/48×[(83.904+ 34.822)3600] ×(2800- 2000)2=18.186 kN·m× (2×3600+ 2800)+ (83.904-34.822 ) ×M1y=1/48[(p jmax+ p j) ×(2B+ B1)+ (p jmak-p j) ×B] ×(L -L1)2 =1/48×[(83.904+ 34.822)2800] ×(3600- 2800)2=13.863 kN·m× (2×2800+ 2000)+ (83.904-34.822 ) ×A sx1=M1x/(0.9×300×345)=195.233mm2106/(0.9×f yx×h0x ) =18.186×300×345)=148.824mm2106/(0.9×A sy1=M1y/(0.9×f yy×h0y ) =13.863×2)第二阶验算M2x=1/48[(p jmax+ p j) ×(2L+ (a+2d x))+ (p jmak-p j) ×L] ×(B -(b+2d y))2 =1/48×[(83.904+3600] ×(2800-(2×3600+ (800+2×600))+ (83.904-34.822 ) ×34.822) ×m(600+2×300))2=67.679 kN·M2y=1/48[(p jmax+ p j) ×(2B+ (b+2d y))+ (p jmak-p j) ×B] ×(L -(a+2d x))22800] ×(3600- =1/48×[(83.904+ 34.822) ×(2×2800+ (600+2×300))+ (83.904-34.822 ) ×m(800+2×600))2=50.388 kN·A sx2=M2x/(0.9×300×745)=336.46mm2106/(0.9×f yx×h0x ) =67.679×300×745)=250.5mm2106/(0.9×A sy2=M2y/(0.9×f yy×h0y ) =50.388×3)第三阶验算M3x=1/48[(p jmax+ p j) ×(2L+ a)+ (p jmak-p j) ×L] ×(B -b)2 =1/48×[(83.904+ 34.822) ×m(2×3600+ 800)+ (83.904-34.822 ) ×3600] ×(2800- 600)2=113.589 kN·M3y=1/48[(p jmax+ p j) ×(2B+ b)+ (p jmak-p j) ×B] ×(L -a)2 =1/48×[(83.904+ 34.822) ×m2800] ×(3600- 800)2=142.677 kN·(2×2800+ 600)+ (83.904-34.822 ) ×300×1145)=367.424mm2106/(0.9×f yx×h0x ) =113.589×A sx3=M3x/(0.9×106/(0.9×300×1145)=461.514mm2f yy×h0y ) =142.677×A sy3=M3y/(0.9×A sx=max(A sx1,A sx2,A sx3)=max(195.233,336.46,367.424)=367.424mm2≤ASX=[(2800/120)+1]×3.14×102/4=1910.167 mm2A sy=max(A sy1,A sy2,A sy3)=max(148.824,250.5,461.514)=461.514mm2≤ASY=[(3600/110)+1]×3.14×102/4=2647.591 mm2 满足要求!。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

基础计算书C 轴交3轴DJ P 01计算一、计算修正后的地基承载力特征值选择第一层粉土为持力层,地基承载力特征值fak=120 kPa ,ηd=2.0,rm=17.7kN/m 3,d=1.05m ,初步确定埋深d=1.5m ,室内外高差0.45m 。

根据《建筑地基基础设计规范》(GB 50007-2011) 式5.2.4 计算修正后的抗震地基承载力特征值 = 139(kPa);二、初步选择基底尺寸A ≧Fk fa −γGA ≧949139−20×1.5=8.7㎡ 取独立基础基础地面a=b=3000mm 。

采用坡型独立基础,初选基础高度600mm ,第一阶h 1=350mm ,第二阶h 2=250mm 。

三、作用在基础顶部荷载标准值结构重要性系数: γo=1.0基础混凝土等级:C30 ft_b=1.43N/mm 2 fc_b=14.3N/mm 2柱混凝土等级: C30 ft_c=1.43N/mm 2 fc_c=14.3N/mm 2钢筋级别: HRB400 fy=360N/mm2 矩形柱宽 bc=500mm 矩形柱高 hc=500mm纵筋合力点至近边距离: as=40mm 最小配筋率: ρmin=0.150% Fgk=949.000kN Fqk=0.000kN Mgxk=14.000kN*m Mqxk=0.000kN*m Mgyk=25.000kN*m Mqyk=0.000kN*m Vgxk=45.000kN Vqxk=0.000kN Vgyk=17.000kN Vqyk=0.000kN永久荷载分项系数rg=1.20 可变荷载分项系数rq=1.40Fk=Fgk+Fqk=949.000+(0.000)=949.000kNMxk=Mgxk+Fgk*(B2-B1)/2+Mqxk+Fqk*(B2-B1)/2=14.000+949.000*(1.500-1.500)/2+(0.000)+0.000*(1.500-1.500)/2=14.000kN*mMyk=Mgyk+Fgk*(A2-A1)/2+Mqyk+Fqk*(A2-A1)/2=25.000+949.000*(1.500-1.500)/2+(0.000)+0.000*(1.500-1.500)/2=25.000kN*mVxk=Vgxk+Vqxk=45.000+(0.000)=45.000kNVyk=Vgyk+Vqyk=17.000+(0.000)=17.000kNF1=rg*Fgk+rq*Fqk=1.20*(949.000)+1.40*(0.000)=1138.800kNMx1=rg*(Mgxk+Fgk*(B2-B1)/2)+rq*(Mqxk+Fqk*(B2-B1)/2)=1.20*(14.000+949.000*(1.500-1.500)/2)+1.40*(0.000+0.000*(1.500-1.500)/2) =16.800kN*mMy1=rg*(Mgyk+Fgk*(A2-A1)/2)+rq*(Mqyk+Fqk*(A2-A1)/2)++=f a f ak b ()-b 3d m ( )-d 0.5=1.20*(25.000+949.000*(1.500-1.500)/2)+1.40*(0.000+0.000*(1.500-1.500)/2) =30.000kN*mVx1=rg*Vgxk+rq*Vqxk=1.20*(45.000)+1.40*(0.000)=54.000kNVy1=rg*Vgyk+rq*Vqyk=1.20*(17.000)+1.40*(0.000)=20.400kNF2=1.35*Fk=1.35*949.000=1281.150kNMx2=1.35*Mxk=1.35*14.000=18.900kN*mMy2=1.35*Myk=1.35*25.000=33.750kN*mVx2=1.35*Vxk=1.35*45.000=60.750kNVy2=1.35*Vyk=1.35*17.000=22.950kNF=max(|F1|,|F2|)=max(|1138.800|,|1281.150|)=1281.150kNMx=max(|Mx1|,|Mx2|)=max(|16.800|,|18.900|)=18.900kN*mMy=max(|My1|,|My2|)=max(|30.000|,|33.750|)=33.750kN*mVx=max(|Vx1|,|Vx2|)=max(|54.000|,|60.750|)=60.750kNVy=max(|Vy1|,|Vy2|)=max(|20.400|,|22.950|)=22.950kN四、计算参数1. 基础总长 Bx=B1+B2=1.500+1.500=3.000m2. 基础总宽 By=A1+A2=1.500+1.500=3.000m3. 基础总高 H=h1+h2=0.350+0.250=0.600m4. 底板配筋计算高度 ho=h1+h2-as=0.350+0.250-0.040=0.560m5. 基础底面积 A=Bx*By=3.000*3.000=9.000m26. Gk=γ*Bx*By*dh=20.000*3.000*3.000*1.000=180.000kNG=1.35*Gk=1.35*180.000=243.000kN五、计算作用在基础底部弯矩值Mdxk=Mxk-Vyk*H=14.000-17.000*0.600=3.800kN*mMdyk=Myk+Vxk*H=25.000+45.000*0.600=52.000kN*mMdx=Mx-Vy*H=18.900-22.950*0.600=5.130kN*mMdy=My+Vx*H=33.750+60.750*0.600=70.200kN*m六、验算地基承载力1. 验算轴心荷载作用下地基承载力pk=(Fk+Gk)/A=(949.000+180.000)/9.000=125.444kPa 【①5.2.1-2】因γo*pk=1.0*125.444=125.444kPa≤fa=139.000kPa轴心荷载作用下地基承载力满足要求2. 验算偏心荷载作用下的地基承载力exk=Mdyk/(Fk+Gk)=52.000/(949.000+180.000)=0.046m因|exk|≤Bx/6=0.500m x方向小偏心,由公式【①5.2.2-2】和【①5.2.2-3】推导Pkmax_x=(Fk+Gk)/A+6*|Mdyk|/(Bx2*By)=(949.000+180.000)/9.000+6*|52.000|/(3.0002*3.000)=137.000kPa Pkmin_x=(Fk+Gk)/A-6*|Mdyk|/(Bx2*By)=(949.000+180.000)/9.000-6*|52.000|/(3.0002*3.000)=113.889kPa eyk=Mdxk/(Fk+Gk)=3.800/(949.000+180.000)=0.003m因|eyk|≤By/6=0.500m y方向小偏心Pkmax_y=(Fk+Gk)/A+6*|Mdxk|/(By2*Bx)=(949.000+180.000)/9.000+6*|3.800|/(3.0002*3.000)=126.289kPaPkmin_y=(Fk+Gk)/A-6*|Mdxk|/(By2*Bx)=(949.000+180.000)/9.000-6*|3.800|/(3.0002*3.000)=124.600kPa3. 确定基础底面反力设计值Pkmax=(Pkmax_x-pk)+(Pkmax_y-pk)+pk=(137.000-125.444)+(126.289-125.444)+125.444=137.844kPa γo*P kmax=1.0*137.844=137.844kPa≤1.2*fa=1.2*139.000=166.800kPa偏心荷载作用下地基承载力满足要求七、基础冲切验算1. 计算基础底面反力设计值1.1 计算x方向基础底面反力设计值ex=Mdy/(F+G)=70.200/(1281.150+243.000)=0.046m因ex≤Bx/6.0=0.500m x方向小偏心Pmax_x=(F+G)/A+6*|Mdy|/(Bx2*By)=(1281.150+243.000)/9.000+6*|70.200|/(3.0002*3.000)=184.950kPa Pmin_x=(F+G)/A-6*|Mdy|/(Bx2*By)=(1281.150+243.000)/9.000-6*|70.200|/(3.0002*3.000)=153.750kPa1.2 计算y方向基础底面反力设计值ey=Mdx/(F+G)=5.130/(1281.150+243.000)=0.003m因ey≤By/6=0.500y方向小偏心Pmax_y=(F+G)/A+6*|Mdx|/(By2*Bx)=(1281.150+243.000)/9.000+6*|5.130|/(3.0002*3.000) =170.490kPa Pmin_y=(F+G)/A-6*|Mdx|/(By2*Bx)=(1281.150+243.000)/9.000-6*|5.130|/(3.0002*3.000)=168.210kPa1.3 因Mdx≠0 Mdy≠0Pmax=Pmax_x+Pmax_y-(F+G)/A=184.950+170.490-(1281.150+243.000)/9.000=186.090kPa1.4 计算地基净反力极值Pjmax=Pmax-G/A=186.090-243.000/9.000=159.090kPaPjmax_x=Pmax_x-G/A=184.950-243.000/9.000=157.950kPaPjmax_y=Pmax_y-G/A=170.490-243.000/9.000=143.490kPa2. 柱对基础的冲切验算2.1 因(H≤800) βhp=1.02.2 x方向柱对基础的冲切验算x冲切面积Alx=max((A1-hc/2-ho)*(bc+2*ho)+(A1-hc/2-ho)2,(A2-hc/2-ho)*(bc+2*ho)+(A2-hc/2-ho )2=max((1.500-0.500/2-0.560)*(0.500+2*0.560)+(1.500-0.500/2-0.560)2,(1.500-0.500 /2-0.560)*(0.500+2*0.560)+(1.500-0.500/2-0.560)2)=max(1.594,1.594)=1.594m2 x冲切截面上的地基净反力设计值Flx=Alx*Pjmax=1.594*159.090=253.574kNγo*Flx=1.0*253.574=253.57kN因γo*Flx≤0.7*βhp*ft_b*bm*ho (6.5.5-1)=0.7*1.000*1.43*1060*560=594.19kNx方向柱对基础的冲切满足规范要求2.3 y方向柱对基础的冲切验算y冲切面积Aly=max((B1-bc/2-ho)*(hc+2*ho)+(B1-bc/2-ho)2,(B2-bc/2-ho)*(hc+2*ho)+(B2-bc/2-ho )2)=max((1.500-0.500/2-0.560)*(0.500+2*0.560)+(1.500-0.500-0.560)2/2,(1.500-0.50 0/2-0.560)*(0.500+2*0.560)+(1.500-0.500-0.560)2/2)=max(1.594,1.594)=1.594m2 y冲切截面上的地基净反力设计值Fly=Aly*Pjmax=1.594*159.090=253.574kNγo*Fly=1.0*253.574=253.57kN因γo*Fly≤0.7*βhp*ft_b*am*ho (6.5.5-1)=0.7*1.000*1.43*1060.000*560=594.19kNy方向柱对基础的冲切满足规范要求八、柱下基础的局部受压验算因为基础的混凝土强度等级大于等于柱的混凝土强度等级,所以不用验算柱下扩展基础顶面的局部受压承载力。