TS7650虚拟带库安装配置步骤

合集下载

VTL软件安装及配置指南

VTL软件安装及配置指南

浪潮虚拟磁带库VTL1000软件安装指南1.硬件平台及软件要求硬件平台为AS500N,前两个盘位做RAID1,安装 Update2 X86_64系统。

Raid1大小为470000M安装CentOS时,具体的分区情况为:boot 239988M/ 222000MSwap 8000MCentOS必选包为Xwindows SystemGNOME Desttop EnvironmentApplications:EditorsServers:Server Configuration ToolsMail ServerDNS Name ServerPostgre SQL DatabaseNetwork Server(iscsi-initiator软件包)DevelopmentDevelopment ToolsSystemAdministrator ToolsSystem Tools(sysstat软件包)Campatibility Arch Support安装完CentOS后重新引导并进入系统!!设置系统root帐号的密码为root软件安装将软件光盘放入光驱,挂载光盘#mount /dev/cdrom /mnt.安装VTL软件默认的安装目录时/usr/local/vtl,安装日志存放在/usr/local/vtl-archive下,在此文件目录下,即为安装过程记录文档,如果需要查看安装过称,可以用命令#less 查看。

#cd /mnt#sh vtlinstall当出现如下时,输入Y,并按回车继续安装。

出现输入Luns数时,如图,键入16或是32,即设定磁盘划16或是32个lun当出现如下图示时,默认选择回车继续,表示此文件系统只有一个。

系统要求选择光纤HBA卡型号target驱动时,由于此VTL需要安装完之后打补丁,所以现在不需要选择具体的FC HBA卡的型号,所以我们选择:q,表示没有光纤target模块的支持。

7650_PC_Suite_chi-sc

7650_PC_Suite_chi-sc

版权所有 © 2002-2003 诺基亚。保留所有权利。
诺基亚 7650 PC 套件
使用蓝牙连接
4
诺基亚 7650 PC 套件
5 为诺基亚 7650 与 PC 之间的连接授权。当手机显示屏上出现 “是否要接受连
接请求”的连接请求时,选择 “是” 。您可以将 PC 设置为已授权,也就是 说,在您的手机与 PC 之间建立连接时,不经过单独授权。要实现这一点,请 转到手机上的 “配对设备”视图,滚动到设备并选择 “选项” 。选择 “设置 为已授权” 。 由于蓝牙设备利用无线电波进行通讯,所以您的手机和其它蓝牙设备不需要相互 直接对准。这两台设备只需要彼此相距不超过 10 米即可,不过,像墙这样的障 碍物或其它电子设备也有可能会干扰连接。 使用蓝牙设备时可能会遇到限制。请咨询您当地的技术支持人员。 蓝牙连接不会自动关闭。您必须用 PC 上的蓝牙软件来关闭它。当您停止在联机 模式中使用 “诺基亚 7650 PC 套件”时,请关闭蓝牙连接。 提示!您可以从 “开始”菜单中找到联 机帮助:选择 “程 序” ,指向 “诺基亚 7650 PC 套件” ,然后 单击 “诺基亚 7650 PC 套件帮助” 。 注意:如果您在将手机连接到 PC 时有问题,请检查诺基亚 7650 手机和 PC 是否已打开,以及您是否选择了正确的通讯端口。另请参阅 “将诺基 亚 7650 连接到 PC”和 “断开连接 / 重新连接诺基亚 7650”联机帮助主 题,以了解详细信息。
3
版权所有 © 2002-2003 诺基亚。保留所有权利。
注意:第一次通过蓝牙将诺基亚 7650 连接到 PC 时,必须事先提供要在蓝 牙连接中使用的手机设备名称。有关为手机指定名称的说明,请参阅诺基 亚 7650 《用户手册》 。一定要激活手机上的蓝牙功能,以便能够找到并连 接诺基亚 7650。转到 “连接功能”并选择 “蓝牙” 。然后将蓝牙选择为 “开” 。为了能够找到手机,请在 “蓝牙”菜单中将 “本手机的可见性” 更改为 “普通” 。 建立蓝牙连接: 1 在 PC 卡或 CompactFlash (CF+) 插槽中一定要插入蓝牙卡,而且 PC 上一定要 安装随蓝牙卡提供的软件,或者请检查 PC 是否提供对蓝牙的内置支持。 PC 中必须有串行端口配置文件,以供蓝牙卡使用。有关详细信息,请参阅随蓝 牙卡或 PC 提供的用户文档。 2 在您的诺基亚 7650 和 PC 间建立串行端口连接。有关如何执行此操作的信 息,请参阅蓝牙软件的用户文档。 3 在任务栏双击 “PC 套件”的 “连接”图标,打开 “连接属性”对话框。一 定要为蓝牙连接选择正确的端口。如果没有选择端口,请选择带有蓝牙功能 的 COM 端口作为连接类型。请注意,您可以选择多个 COM 端口。 注意:如果您无法选择要使用的端口,则说明其它 PC 应用程序正在使 用该端口。要将 “PC 套件”用于该端口,必须关闭或临时禁用这个应 用程序。 4 如果您是首次使用蓝牙连接方式来连接诺基亚 7650 和 PC,则需要将这两台 设备组成一对。要将这两台设备组成一对,您需要给这两台设备都输入密 码。创建您自己的密码 (长度为 1-16 个字符,使用数字) ,并在手机和 PC 提出要求时给它们都输入相同的密码。此密码只使用一次,所以您不必记住 它。有关详细信息,请参阅诺基亚 7650 《用户手册》 。

ION 7550_7650用户操作指南_A4(中文版)

ION 7550_7650用户操作指南_A4(中文版)

用户操作指南北京特域科技有限公司声明:本手册由北京特域科技有限公司翻译,仅供参考之用,所有内容以包装箱内”ION 7550 / ION 7650 Installation Guide”为准。

若有疑问请参考英文版原文,或致电北京特域科技有限公司。

本手册内容如有变更,恕不另行通知。

北京特域科技有限公司ION7550/7650电能质量监控装置用户操作指南目录第一部分:ION 7550 / ION 7650安装指南 (4)安装注意事项 (4)ION7550/ION7650的可选类型 (6)装置的尺寸 (7)第一步:装置的安装 (9)第二步:接地端的连接 (9)第三步:DI/DO和AI/AO的接线 (10)第四步:电压和电流输入的接线 (13)第五步:通信接线 (17)第六步:电源接线 (19)第七步:装置上电 (19)第八步:装置前面板的参数设置 (19)第十步:查看数据 (25)第二部分:ION 7550 / ION 7650面板操作指南 (27)●显示内容的选择 (27)●数值整定 (27)●面板显示内容 (28)●面板设置 (29)●典型接线示意图 (33)●机械安装尺寸 (34)●装置的安装 (35)第一部分:ION 7550 / ION 7650安装指南这种符号表示在装置内或其外壳上存在危险电压,如果不采取适当的预防措施则可能对人体造成电击,重伤或死亡的伤害。

这种符号警告使用者存在危险,如果不采取适当的预防措施则可能对人体造成轻中度伤害,损坏财物或设备本身。

这种符号提示用户注意重要的安装,操作和维护事项。

安装注意事项ION 7550 / ION 7650仪表的安装和维护只能由经过足够的培训,有高电压大电流设备操作经验的合格的工程技术人员来进行。

仪表的安装必须符合当地和国家的电气标准。

如不遵照以下指示可能导致重伤或死亡。

◆在ION 7550 / ION 7650仪表的正常运行中,端子排、电压互感器(PT)、电流互感器(CT)、数字(状态)输入、控制电源和外部I/O回路中都存在危险电压。

虚拟打印机安装说明

虚拟打印机安装说明

一、关于安装
安装过程中,若有杀毒软件提示,请选择全部信任。

注意:对win7用户(包含32位和64位系统)安装最完整可靠的注意事项:
1、解压缩后,安装文件要右键选择管理员身份运行;
2、安装过程会报两个错误。

不要管他,继续。

3、首次运行,点击快捷方式时,要右键选择管理员身份运行。

再次运行时不受限制。

二、关于使用
如果您没有A3打印机,又想自己打印的话,请参考下列方法中的办法“C”:三个办法:
a:您可以尽量选择安装有A3打印机的计算机来安装个人版。

b:您可以把已经录入完毕的个人信息文件(加密文件,不能手工打开)选择参评人员导出并送到您所在单位人事部门(或者您的人事代理部门),由单位版引入后填写审核信息并打印。

c:使用虚拟打印机直接输出PDF文档,该文档可以拷贝到打印店,切记打印成规定的A3格式。

虚拟打印机软件下载见主页“软件下载”
安装:先运行CuteWriter.exe文件,再运行converter.exe文件,安装过程完毕。

使用:点击您的计算机“开始”--“打印机和传真”,右键选择“CutePDF Writer”为“默认打印机”。

点击“参评人员”--“参评人员更改”,单击被选中人员,选择“更改选中纪录”,再选择“打印”,会显示一览表,最后点击左上角打印机符号即可。

再次感谢您的耐心阅读!。

Step7 v5.5CN(中文版)及PLCSIM仿真器下载安装步骤详解【范本模板】

Step7 v5.5CN(中文版)及PLCSIM仿真器下载安装步骤详解【范本模板】

Step7 v5。

5CN(中文版)下载及仿真器安装教程一:先将安装包解压仿真器plcsim文件没有可以另行下载二:打开STEP7 V5.5文件夹,双击setup.exe,进行安装,如果提示电脑需要重启或如图所示则需要在电脑的注册表里删除一个注册表就不提示重启了,具体方法:运行注册表命令regedit或者regedit32,在注册表内“HKEY_LOCAL_MACHINE\System\CurrentControlSet\Control\Session Manager\"中删除注册表“PendingFileRenameOperations”,右击它删除。

三、双击setup。

exe之后,选择安装简体中文,如图下一步.四、下一步选择接受,再下一步。

五、程序进入安装状态,大概会花费十几分钟。

进入逐个程序安装,到这里选择下一步。

在此选择典型安装,您可以选择安装到其他磁盘,下一步。

选择简体中文,下一步在此点击安装,程序会继续进行安装。

这里需要几分钟出现这个窗口点击PC Adapter然后安装,关闭选择立即重启电脑,重启完后再授权。

重启后电脑桌面上会多三个图标接下来对软件授权Windows 7:打开安装包中的这个文件完成上面三步点击ALL,完成即可下面是仿真器的安装,安装包中PLCSIM_V54_SP5这个文件仿真安装包,需要注意的是,安装时需将这个文件拷贝在之前step7安装路径下,找到common files 这个文件将文件拷贝在下面这个文件里打开安装之前先检查,之前这个注册表是否被删除,因为电脑重启后此文件将恢复,须重新删除再进行安装删除后即可安装安装完成后,打开step7软件,会发现下面这个图标由灰变亮了,表示可以使用仿真器可模拟接口关闭。

TS7610,TS7650与TS7650G的区别

TS7610,TS7650与TS7650G的区别

TS7610是一款入门级虚拟带库,而TS7650和TS7650G则是IBM的高端虚拟带库。

TS7610(3959-SM1)是IBM新推出的一款入门级虚拟带库,它主要针对中小型企业的快速备份需求,TS7610的基本单元是由一个四核 2.33GHZ主频的Intel Xeon处理器,24GB缓存,12块1TB的SATA硬盘和一块双端口的4Gbps的光纤HBA 卡组成。

TS7610可以提供两种容量配置 4.4TB(4TiB)和5.9TB(5.4TiB),可以虚拟4个TS3500磁带库,64个LTO3虚拟驱动器,8192个虚拟磁带槽位,最大可支持 25:1的重复数据删除比率。

TS7650(3958-AP1)基本单元是一台 x3850 M2 服务器,16核处理器,2.27GHz 主频,32GB内存,其后端默认配置的是DS4700的盘阵内置450GB的光纤硬盘。

TS7650根据后端存储控制器和扩展柜的不同组合方式会有三种容量选择,分别是7TB,18TB,36TB,36TB(cluster),这三种容量都是做完RAID之后的可用容量。

TS7650所支持的备份速率每节点可达500MB/s,最大可支持25:1的重复数据删除比率,最大可支持12个虚拟带库,256个虚拟驱动器,128,000个虚拟槽位。

TS7650G(3958-DD4)这是一款网关产品,基本单元是一台x3850 X5的服务器,32核处理器,2.27Ghz主频,64GB内存。

其后端可接从低端到高端以及第三方的满足产品兼容性的磁盘存储,最大支持的容量可达到 1PB,所支持的备份速率每节点可达500MB/s(双节点cluster配置可达1000MB/s),最大可支持25:1的重复数据删除比率,最大可支持16个虚拟带库,256个虚拟驱动器,512,000个虚拟槽位。

虚拟打印机的安装教程

虚拟打印机的安装教程
虚拟打印机的安装教程
首先我们需要做的就是安装这一款打印机,可以打百度上搜索,下载完成之后并安装,安装完成之后会在打印机和传真里面生成一个虚拟打印机,我们可以右键该打印机,可以将其设置为默认打印机,我们在该打印机上面右键,设置为默认打印机即可,我们也可以共享该打印机,我们在该Pdf虚拟打印机上面右键,然后选择属性选项,在打开的该虚拟打印机属性窗口中,我们切换到共享选项卡,我们要勾选,那就把共享这台打印机给勾选上吧。

然后单击确定就可以共享了,当然我们还可以做一些其他的设置,我们还可以为该虚拟打印机设置权限,比如设置那些用户可以访问,设置好之后现在我们来测试一下远程打印,我们打开开始菜单,然后选择运行选项,在运行选项窗口中输入远程打印服务器的.IP地址,然后单击确定。

连接完成之后,我们打开记事本,随便输入一些文字来测试打印,输入好之后选择菜单栏上的文件选项,再选择下拉列表中的打印选项,这里我就输入本机地址给大家做演示而已,基本的一些设置就是这样了,还有一些小设置大家可以自己尝试一下设置看看。

TS7520 TS7530 Call Home 解除安装指南(3954-CV6 CV7虚拟化引擎)使

Customer Installation InstructionsTS7520/TS7530 Call Home Uninstallation Procedure using the Call Home Utility Disk for 3954-CV6/CV7 Virtualization EngineCall Home Utility Disk– Disk for uninstalling the TS7520/TS7530 Call Home function if it is an undesired function.TS7520 Software Version 2.1 (Build 1382)TS7530 Software Version 3.1 (Build 1465)call_home_utility_disk.zipTS7520/TS7530 Call Home Uninstallation Procedure for 3954-CV6/CV7 Virtualization EngineCustomer Installation InstructionsTS7520/TS7530 Call Home Uninstallation Procedure using the Call Home Utility Disk for 3954-CV6/CV7 Virtualization EngineCall Home Utility Disk– Disk for uninstalling the TS7520/TS7530 Call Home function if it is an undesired function.TS7520 Software Version 2.1 (Build 1382)TS7530 Software Version 3.1 (Build 1465)© Copyright International Business Machines Corporation 2008. All rights Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.Before Installation (Section 1 through 5)Warning:Throughout this documentation, there are occurrences of service passwords and sudo commands that are used to manage and configure the product. Improper use of these commands and passwords poses significant risk to the product and your data. It is imperative that these commands and passwords are used only as documented.1 Machines AffectedThis is an uninstallation procedure for the TS7520/TS7530 3954-CV6/CV7 Virtualization Engine.This procedure should be applied to TS7520 systems with software version 2.2 or TS7530 systems with software version 3.1 that have Call Home on them. It should only be applied if Call Home is not a desired functionality.2 PrerequisitesFor more information on the Call Home functionality and its benefits, please cosult the TS7520 Call Home Function Installation and Setup Guide or the TS7530 Call Home Setup Guide.Call Home should be installed on the desired TS7520/TS7530 in which the Call Home function is undesired.3 Purpose and DescriptionThis procedure should be applied to all TS7520 systems with software version 2.2 or TS7530 systems with software version 3.1 that have Call Home. It should only be applied if Call Home is not a desired functionality.4 Procedure TimeThe average time to apply this procedure on an HA configuration is 30 minutes. The average time required to verify Call Home uninstallation on an HA configuration is 10 minutes. The number of persons required to apply this procedure is one.5 Details of Performing the Call Home Uninstallation ProcedurePerform the steps outlined in sections 5.1 and 5.2 on all servers with Call Home. The following programs will be uninstalled:1.IBM Electronic Service Agent (eSA)2.IBM Director Core ServicesNote: It is not necessary to suspend failover during this procedure because it does not require a system shutdown or a system reboot.5.1 Performing the Call Home Uninstallation ProcedureUse the following procedure to uninstall the Call Home functionality.1.Insert the Call Home Utility Disk TS7520/TS7530 server’s CD-ROM drive.2.Log in to PuTTY by selecting Start > Programs > PuTTY > PuTTY. The user id isvetapeservice and the password is service4u. Refer to Appendix A in the Call Home documentation for information on logging into the server using PuTTY.3.To mount the CD-ROM, on the command line enter the command:sudo mount /dev/hda /media/cdrom4.To start the recovery script, on the command line, enter the command:/media/cdrom/Call_Home_Uninstall.sh5.When the recovery process finishes, unmount the CD-ROM, on the command line enterthe command:sudo umount /dev/hda5.2 Call Home Uninstallation VerificationUse the following procedure to verify Call Home functionality uninstallation.6.Log in to PuTTY by selecting Start > Programs > PuTTY > PuTTY. The user id isvetapeservice and the password is service4u. Refer to Appendix A in the Call Home documentation for information on logging into the server using PuTTY.7.To verify eSA uninstallation on the command line enter the commandls /home/esadmin/ServiceAgenta.Result: /bin/ls: /home/esadmin/ServiceAgent: No such fileor directory8.To verify Director Core Services uninstallation on the command line enter the command:ls /opt/ibm/directora.Result: . .. bin cimomb.These are residual directories that may be left behind, but all the other directoriesare removed and Director Core Services will no longer function.。

TS带库安装全攻略

T S带库安装全攻略The Standardization Office was revised on the afternoon of December 13, 2020TS3310带库安装全攻略这次安装的带库包括:3576-L5B(控制模块,简称CM),3576-E9U(扩展模块,简称EM)也叫I/O station。

如果只有一个L5B,那安装起来非常简单,加上一个EM(最多可以带4个EM),安装过程就要注意以下几点:一、拆内置包装物1. 前面板组件展示1 存取口2 电源按钮3 绿色供电(液晶指示灯)4 琥珀色操作员干预警报指示灯5 操作员面板(触摸式)6 5U控制模块7 I/O站8 9U扩展模块注:一个CM+EM可以把CM放上面,或放下面都可以,按个人喜好。

但一定要注意顶板和底板位置。

不管先前顶板原安装哪里,谁放在上面顶板就要盖在上面,反之底板也一样。

这个是来控制机械臂的活动范围。

2. 后面板组件展示1 控制模块(L5B)2 扩展模块(E9U)3 控制模块磁带机(显示FC磁带机)4 扩展模块磁带机5 电源控制器6 控制模块与扩展模块的连接线7 客户用网络端口(4端口提供)8 WEB方式管理磁带库接口(RJ45)注:随机有两个堵头,大约位置在8那里和最左下角位置,切记一定要安装上在开箱时,首先把CM的顶板打开,里面会有固定机械臂(PICKER)的纸板和卡扣,还有一些黄色标志的固定条(打开机器时都会看到),把这些统统拿掉。

不然加电时会影响到机械臂的运动。

二、机械臂的一些装置机械臂锁扣装置,如果CM是放在上面,安装时要把该装置打开,也就是图示的样子。

注意全部安装完毕后,把该装置放回到里面,这样机械臂就可以上下滑动了这叫gear rack(齿轮装置滑轨)也就是picker移动的轨道。

注意:如果有EM的话,一定要调整此位置,不然系统自检不会通过。

我是看了N次的install guide,可惜总不得要领。

最新vtl软件安装及配置指南教学教材

浪潮虚拟磁带库VTL1000软件安装指南1.硬件平台及软件要求硬件平台为AS500N,前两个盘位做RAID1,安装CentOS4.0 Update2 X86_64系统。

Raid1大小为470000M安装CentOS时,具体的分区情况为:boot 239988M/ 222000MSwap 8000MCentOS必选包为Xwindows SystemGNOME Desttop EnvironmentApplications:EditorsServers:Server Configuration ToolsMail ServerDNS Name ServerPostgre SQL DatabaseNetwork Server(iscsi-initiator软件包)DevelopmentDevelopment ToolsSystemAdministrator ToolsSystem Tools(sysstat软件包)Campatibility Arch Support安装完CentOS后重新引导并进入系统!!设置系统root帐号的密码为root2.VTL软件安装将VTL4.0软件光盘放入光驱,挂载光盘#mount /dev/cdrom /mnt2.1.安装VTL软件默认的安装目录时/usr/local/vtl,安装日志存放在/usr/local/vtl-archive下,在此文件目录下,vtlinstall-26Jan08-222434.log即为安装过程记录文档,如果需要查看安装过称,可以用命令#lessvtlinstall-26Jan08-222434.log查看。

#cd /mnt#sh vtlinstall当出现如下时,输入Y,并按回车继续安装。

出现输入Luns数时,如图,键入16或是32,即设定磁盘划16或是32个lun当出现如下图示时,默认选择回车继续,表示此文件系统只有一个。

系统要求选择光纤HBA卡型号target驱动时,由于此VTL需要安装完之后打补丁,所以现在不需要选择具体的FC HBA卡的型号,所以我们选择:q,表示没有光纤target模块的支持。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

TS7650虚拟带库系统安装配置步骤目录(一) TS7650安装配置步骤 (3)1)安装ProtecTier Manager客户端 (3)2)配置第一个Node (6)1. 安装定制的RedHat Linux (6)2. 拷贝I.B.M虚拟带库软件到该Node的本地硬盘 (7)3. 更新cman rpm包到光盘所带的最新版 (7)4. 安装ProtecTIER rpm (7)5. 安装RAS 相关rpm (8)(安装流程与上面类似,过程略) (8)6. 配置ProtecTIER Cluster的第一个节点 (8)7. 配置创建Repository的必须资源 (10)8. 完成第一个Node安装并验证 (11)3)配置第二个Node (17)1. 重复执行第一个Node上执行过的第1-3步 (17)2. 关闭第一个节点的服务 (17)3. 把第2个节点加入集群 (17)把第2个节点的机器启动起来,执行以下步骤:# menu (17)4. 验证两个Node的Cluster配置 (19)4)创建虚拟带库及虚拟磁带 (19)(一)TS7650安装配置步骤1)安装ProtecTier Manager客户端选择从CD或者其他安装介质安装ProtecTier Manager客户端,安装过程如下:点击next进入下一步:继续下一步:选择相应的安装目录,进入下一步:建立需要的快捷方式,进入下一步:确认以上信息,开始安装:安装ProtecTier Manager结束。

2)配置第一个Node1.安装定制的RedHat Linux将TS7650G 第一个Node(可以自行定义)开机,把System Recovery DVD放入光驱,在下图所示的提示符输入linux ks=cdrom,开始安装RedHat Linux,根据提示输入几次YES,并按回车,直到安装结束后系统自动重启,自检过程中取出光盘,系统将启动安装好的RedHat Linux。

2.拷贝I.B.M虚拟带库软件到该Node的本地硬盘将ProtecTIER CD放入光驱,登录RedHat Linux,用户名是root,密码admin,执行如下命令。

# mkdir /mnt/cdrom# mount -o ro /dev/cdrom /mnt/cdrom# cd /install# cp /mnt/cdrom/* .3.更新cman rpm包到光盘所带的最新版执行rpm -qa | grep cman检查系统中cman的现有版本,如果比光盘中的cman rpm包旧,则执行如下命令升级cman。

# rpm -Uvh cman-x.x.xx-x.el5.x86_64.rpm4.安装ProtecTIER rpm执行如下命令,安装虚拟带库核心组件# tar -xvf PT_Linux_Vx.x.x.x-full.x86_64.tar# cd PT_Linux_Vx.x.x.x-full.x86_64# ./autorun执行如下命令,安装虚拟带库核心组件# tar -xvf PT_Linux_Vx.x.x.x-full.x86_64.tar# cd PT_Linux_Vx.x.x.x-full.x86_64# ./autorun当./autorun脚本执行结束后系统将自动重新启动5.安装RAS 相关rpm(安装流程与上面类似,过程略)说明:以上全部过程也需要在第二个Node上执行。

6.配置ProtecTIER Cluster的第一个节点系统启动结束后,首先关闭另一个Node(poweroff ,如果有的话),然后登录到该Node,初始用户名和密码分别为root和admin,执行如下命令:# menu选择“1”选择1,”Configure ProtectTIER node”,之后进入如下菜单,选1,“Configure external (customer’s network) IP address”根据提示输入必要的信息,包括用户管理网络的IP,子网掩码和网关,以及Node的主机名,其余的保留默认值。

回车确认,执行示例输出如下:Would you like to stop the VTFD service? (yes|no) yesStopping services, please waitStopping Cluster Services [ Done ]Services stoppedChecking conditions...Checking BOM [ Done ]Checking for existing nodes [ Done ]Checking repository [ Done ]Checking conditions donePlease provide the following information:-----------------------------------------Customer Network, IP Address [192.168.167.161]:Customer Network, Netmask [255.255.255.0]:Customer Network, Default Gateway:Customer Network, Hostname [node1]:Configuring network [ Done ]Restarting Network Service [ Done ]Stopping cluster [ Done ]Configuring cluster [ Done ]Starting cluster [ Done ]Installing NTP [ Done ]Starting VTFD [ Done ]install ended successfullyValidation will start in 10 secondsTesting connectivity to the Default Gateway [ Done ] Getting number of nodes [ Done ]This is a 1 node cluster, will not test fencing Validation endedInstall ended successfully7.配置创建Repository的必须资源通过下面的命令验证预期的磁盘配置情况# fdisk –l# multipath –ll确认LUN都扫描到,多路径都正常后,输入命令:#menu选择1选择6 File Systems Management选择1 配置所有可用设备,等待所有文件系统配置完毕。

8.完成第一个Node安装并验证打开PT Manager,登录该Node,用户名和密码均为ptadmin,创建Repository输入第一个Node配置的IP地址添加成功以后,登录按上述过程创建了Repository,系统最后显示如下接下来执行/opt/dtc/install/ptconfig –validate以验证系统配置,成功验证后一个单节点的ProtecTIER Cluster 成功建立。

3)配置第二个Node1.重复执行第一个Node上执行过的第1-3步2.关闭第一个节点的服务登录第一个节点,输入menu. 进入菜单后,选择2” Manage ProtecTIER services”->4” Stop ProtecTIER services only (including GFS)”3.把第2个节点加入集群把第2个节点的机器启动起来,执行以下步骤:# menu选择1“ProtectTIER Configuration”选择1,”Configure ProtectTIER node”,之后进入如下菜单,选1,“Configure external (customer’s network) IP address”根据提示输入必要的信息,包括用户管理网络的IP,子网掩码和网关,以及Node的主机名,其余的保留默认值。

重复执行第一个Node执行过的第5步,输入第二个节点的参数Customer Network, IP Address [192.168.167.161]: 10.10.2.89Customer Network, Netmask [255.255.255.0]: 255.255.255.0Customer Network, Default Gateway: 10.10.2.254Customer Network, Hostname [node1]: vtl01_node2确认后按回车,屏幕输出以下信息至此,节点已加入集群4.验证两个Node的Cluster配置登录PT Manager验证节点的状态正常。

上图中可以看出,正常情况下Status 应该是Ok,Management service应该是Online,VT是Online。

4)创建虚拟带库及虚拟磁带登录PT Manager,运行Create library向导输入VT name选择虚拟带库的类型,默认是TS3500,备份软件是NBU的,请选择V-TS3500选择虚拟Drive类型,目前只支持ULT3580-TD3输入每个Node上虚拟Drive的个数合理分配Drive到相应的Port Node1:Node2:。

相关文档
最新文档