60 Hz.Product line catalogue
SOLENOID VALVES 产品名说明书

USOLENOID VALVESno voltage release (tamperproof)manual reset construction1/4213FEATURES• The valves are certified according to IEC 61508 Functional Safety data and have SIL-3 capability (Exida approval)• Compact Tamperproof/Manual Reset function which means that the valve has to be energized as well as manually operated before it stays in the "latched" position. Because of the tamperproof feature there will be no flow from port 3 to port 2 if only the push button is pressed. The No Voltage Release (NVR) function will make sure that the valve trips when de-energized• The solenoid valves are recommended for pilot applications with basic flow, wide pressure ranges and no minimum operating pressure• PTFE rider rings and graphite-filled PTFE seals reduce friction and eliminate sticking• Coils used in metal enclosures have class H insulation materials• Peak voltage suppression diodes are standard in DC solenoids with metal enclosures• The solenoid valves satisfy all relevant EC DirectivesGENERALDifferential pressure 0 - 10 bar [1 bar = 100kPa]Maximum viscosity 65 cSt (mm 2/s)Response times75 - 100 msfluids (✶)temperature range (TS)seal materials (✶)air, inert gas, water, oil-20 to +120°C -40 to + 40°CFPM (fluoroelastomer)VMQ ((sillicone)MATERIALS IN CONTACT WITH FLUID(✶) Ensure that the compatibility of the fluids in contact with the materials is verifiedBrass bodyStainless steel body Body Brass AISI 316Stem Stainless steel Stainless steel Core tube Stainless steel Stainless steel Core and plugnut Stainless steel Stainless steel Springs Stainless steel Stainless steel Sealings and poppets FPM or VMQFPM or VMQ Rider Ring PTFEPTFEPOWER LEVELS - cold electrical holding values (watt)SPECIFICATIONSpipe size orificesizeflowcoefficientKv operating pressuredifferential (bar)powerlevel prefix optional solenoidsbasic catalogue numbermin.max. (PS)NEMA 7&9ATEX / IECExIP65air/water (✶)Ex d Ex e mb Ex mb(mm)(m 3/h)(l/m)~/=~/=EF NF EM PV SC brass stainless st.U - Universal, FPM sealings and poppets, manual reset1/45,70,559,2010BP ●●●❍● 327B021 327B0221/45,70,559,2010MP -●●-● 327B221 327B2221/45,70,559,2010RP -●●-● 327B121 327B122U - Universal, VMQ sealings and poppets, manual reset1/45,70,559,2010BP ●●●❍● 327B071 327B0721/45,70,559,2010MP -●●-● 327B271 327B2721/45,70,559,2010RP -●●-● 327B171 327B172U - Universal, FPM sealings and poppets, manual reset tamperproof1/45,70,559,2010BP ●●●❍● 327B031 327B0321/45,70,559,2010MP -●●-● 327B231 327B2321/45,70,559,2010RP -●●-● 327B131 327B132U - Universal, VMQ sealings and poppets, manual reset tamperproof1/45,70,559,2010BP ●●●❍● 327B081 327B0821/45,70,559,2010MP -●●-● 327B281 327B2821/45,70,559,210RP-●●-●327B181327B182Select 8 for NPT ANSI 1.20.3 or Select G for ISO G(228/1)● Available feature ❍ Available feature in DC only- Not available3/2Series327Pneutrol International Ltd are Platinium Distributors for ASCO NumaticsContactus:5CaulsideDrive,Antrim,NorthernIreland,*************************************************:+44(0)2894481800PRODUCT SELECTION GUIDESTEP 1Select basic cataloguenumber,including pipe thread indentification letter. Refer to the specifications table on page 1.Example: 8327B021STEP 2Select prefix (combination). Refer to the specifications table on page 1 and the prefix table on page 2, respect the indicated power level.Example: NFSTEP 3Select suffix (combination) if required. Refer to the suffix table on page 2, respect the indicated power level.Example: COSTEP 4Select voltage. Refer to standard voltages on page 3.Example: 230V / 50/60 Hz STEP 5Final catalogue / ordering number. Example:NF 8327B021 CO 230V / 50/60 HzPREFIX TABLEprefix description power level 1234567LP RP MP BPE F Explosionproof - NEMA 7, 9 - Zinc plated steel conduit ---●E V Explosionproof - NEMA 7, 9 - 316 SS conduit ---●E M Waterproof IP67 - Metal enclosure (EN/IEC 60079-7+18, 61241-1)*-●●●E T Threaded conduit/hole (M20 x 1,5)-●●●I S S C Intrinsically safe with SC coil (EN/IEC 60079-11+26, 61241-11)*----N F Flameproof - Aluminium (EN/IEC 60079-1, 60079-31)*-●●●P V Encapsulated epoxy moulded (EN/IEC 60079-18, 61241-18)*---❍S C Solenoid with spade plug connector (EN/IEC 60730)-●●●W P Waterproof IP67 - Metal enclosure -●●●W P I S I.S. with Metal IP67 enclosure (EN/IEC 60079-11+26, 61241-11)*----W S Waterproof IP67 - 316 SS enclosure -●●●W S E M Waterproof IP67 - 316 SS enclosure (EN/IEC 60079-7+18, 61241-1)*-●●●W S I S I.S. with 316 SS IP67 enclosure (EN/IEC 60079-11+26, 61241-11)*----WS N F Flameproof - 316 SS (EN/IEC 60079-1, 60079-31)*-●●●T Threaded conduit (1/2" NPT)-●●●H C Class H - Battery charging circuit ---●H T Class H - High temperature----X Other special constructions-●●●SUFFIX TABLEsuffix descriptionpower level 12345LP RP MP BP E EPDM (ethylene-propylene)----J CR (chloroprene)----N Oxygen service (CR (chloroprene))----N V FPM (fluoroelastomer) and parts cleaned for oxygen service -●●●C O Epoxy coating on all external surfaces -●●●M BMounting bracket----M O Push type manual operator -●●●M S Screw type manual operator (1)-●●●MMetering device----● Available feature ❍ Available feature in DC only- Not available * A TEX solenoids are also approved according to EN 13463-1 (non electrical valves) (1)Functional Safety certification is not applicable with this featureOPTIONS & ACCESSORIEScatalogue number spare part kit no.(2)mounting bracket ~ / =SC 327B021C123670⏹SC 327B022C123670⏹SC 327B031C131237⏹SC 327B032C131237⏹SC 327B071C117644⏹SC 327B072C117644⏹SC 327B081C117645⏹SC 327B082C117645⏹SC 327B121C132251⏹SC 327B122C132251⏹SC 327B131C132253⏹SC 327B132C132253⏹SC 327B171C117646⏹SC 327B172C117646⏹SC 327B181C117647⏹SC 327B182C117647⏹SC 327B221C132251⏹SC 327B222C132251⏹SC 327B231C132253⏹SC 327B232C132253⏹SC 327B271C117648⏹SC 327B272C117648⏹SC 327B281C117649⏹SC 327B282C117649⏹Select 8 for NPT ANSI 1.20.3 or select G for ISO G(228/1)(2)Standard prefixes/suffixes are also applicable to kits ⏹ Mounting holes in bodyORDERING EXAMPLES VALVES:SC 8327B 02124V /DC WSEMT G 327B 022CO24V /DCNFET G 327B 021230V /50/60 Hz WSEMG 327B 02224V /DC NF 8327B 231CO 24V /DC WS G 327B 021CO 24V /DCEM 8327B 221230V /50/60 Hz PV 8327B 032CO 24V /DCEFG327H 022CO240V /50/60 Hzprefix (3)pipe thread voltage basic number (3)suffixORDERING EXAMPLES KITS:C131237(4)PV C123670NF C131237WSEM C123670prefixsuffixbasic number(3)Prefix EF and EV should always be used in conjunction withchange letter H in the basic number (4)Basic kit number applies to SC coil constructionPneutrol International Ltd are Platinium Distributors for ASCO NumaticsContactus:5CaulsideDrive,Antrim,NorthernIreland,*************************************************:+44(0)2894481800EXPLANATION OF TEMPERATURE RANGES OF SOLENOID VALVESValve temperature range The valve temperature range (TS) is determined by the selected seal material, the temperaturerange for proper operation of the valve and sometimes by the fluid (e.g. steam)Operator ambient temperature range The operator ambient temperature range is determined by the selected power level and thesafety codeTotal temperature range The temperature range of the complete solenoid valve is determined by the limitations of bothtemperature ranges aboveELECTRICAL CHARACTERISTICSCoil insulation class HElectrical safety IEC 335Standard voltages DC (=) 24V - 48V; Allowable voltage variation ± 10%AC (~) 24V - 48V - 115V - 230V/50/60Hz; Other voltages are available on requestprefix optionpower ratings operatorambienttemperaturerangesafety codeelectricalenclosureprotection(EN 60529)replacement coil / kittype(2) inrush holding hot/cold~~=~=(VA)(VA)(W)(W) (C°)(1)230V/50/60 Hz24V/DCBasic power (BP)SC10,010,010,09,0/11,2-40 to +55EN 60730IP65, moulded123664-017400425-14201 WP/WS10,010,010,09,0/11,2-40 to +55EN 60730IP67, steel /SS400915-017400913-14203 NF/WSNF10,010,010,09,0/11,2-60 to +40/60II2G Ex d IIC Gb T6/T5, II2D Ex t IIIC Db IP67, alu./SS 400915-017400913-14205 EM/WSEM10,010,010,09,0/11,2-40 to +40II2G Ex e mb II T3, II2D Ex tD A21IP67, steel /SS 400915-017400913-14203 PV---9,0/11,2-40 to +55II2G Ex mb II T4, II2D Ex mD 21IP67, moulded- - (3)06 EF/EV12,012,012,09,3/11,6-40 to +52/40NEMA type 7 and 9NEMA 4X276002-058D238714-006D07 Medium Power (MP)SC5,85,85,85,2/5,7-40 to +90EN 60730IP65, moulded400924-297400923-44202 WP/WS5,85,85,85,2/5,7-40 to +90EN 60730IP67, steel /SS400921-297400914-44204 NF/WSNF5,85,85,85,2/5,7-60 to +60/75/90II2G Ex d IIC Gb T6/T5/T4, II2D Ex t IIIC Db IP67, alu./SS 400921-297400914-44205 EM/WSEM5,85,85,85,2/5,7-40 to +40/75/90II2G Ex e mb II T5/T4/T3, II2D Ex tD A21IP67, steel /SS400921-297400914-44204 Reduced Power (RP)(4)SC3,73,73,73,2/3,6-40 to +55EN 60730IP65, moulded - (4)400923-04202 WP/WS3,73,73,73,2/3,6-40 to +55EN 60730IP67, steel /SS - (4)400914-24204 NF/WSNF3,73,73,73,2/3,6-60 to +60II2G Ex d IIC Gb T6, II2D Ex t IIIC Db IP67, alu./SS - (4)400914-24205 EM/WSEM3,73,73,73,2/3,6-40 to +40/55II2G Ex e mb II T6/T5, II2D Ex tD A21IP67, steel /SS - (4)400914-24204 (1) Temperature range can be limited by sealings(2) Refer to the dimensional drawings on page 4 and 5(3) Multiple coil kits are available under ATEX/IECEx, contact us (4) AC (~) limited to 127V/50/60Hz or 125V/DC- Not availableELECTRICAL CONNECTIONSprefix connectionSC Spade plug connector with cable gland EN175301-803A (ISO 4400) for cables with an outer dia-meter from 6 to 10 mmWP, WS, EM, WSEM M20 cable gland for cables with an outer diameter from 7 to 12 mm. With an internal and external facility for an earthing or bonding conductorNF, WSNF1/2" NPT threaded cable entry. Enclosures are supplied without cable glandNFET, WSNFET M20 x 1,5 threaded cable entry. Enclosures are supplied without cable glandPneutrol International Ltd are Platinium Distributors for ASCO NumaticsContactus:5CaulsideDrive,Antrim,NorthernIreland,*************************************************:+44(0)2894481800ADDITIONAL OPTIONS●Ex mb/mD (prefix "PV") solenoid can be supplied with various cable lengths ●Compliance with "UL", "CSA" and other local approvals available on request ●Manual Reset constructions suitable for -40°C are available on requestINSTALLATION●Multi language installation/maintenance instructions are included with each valve ●The solenoid valves can be mounted in any position without affecting operation ●The mounting holes are provided in the valve body●Threaded pipe connection identifier is 8 = NPT (ANSI 1.20.3); G = G (ISO 228/1)●Declarations of conformity are available on request●Ex e mb Prefix "EM" execution: solenoid enclosure has a cable gland with integral strain relief for cables with an o.d.from 7 to 12 mm and is provided with an internal and external connection facility for an earthing or bonding conductor ●Ex d Prefix "NF/WSNF" enclosure is provided with a 1/2" NPT threaded entry hole, M20 x 1,5 (prefix "ET") is optional Both are supplied without cable gland●All DC solenoids with metal enclosure are provided with switch-off peak voltage suppression diodes●T o comply with IEC 61508 (SIL) the valves must be provided with a specific exhaust protector (as shown on page 6) or equalDIMENSIONS (mm), WEIGHT(kg)TYPE 01:TYPE 02:Epoxy mouldedSC: IEC 335 / ISO 4400Epoxy mouldedSC: IEC 335 / ISO 4400327B021 / B022 / B031 / B032327B121 / B122 / B131 / B132 / B221 / B222 / B231 / B232TYPE 03:TYPE 04:Metal, epoxy coated / AISI 316 SS WP / WS: IEC 335EM / WSEM: EN/IEC 60079-7+18, 61241-1Metal, epoxy coated / AISI 316 SS WP / WS: IEC 335EM / WSEM: EN/IEC 60079-7+18, 61241-1327B021 / B022 / B031 / B032327B121 / B122 / B131 / B132 / B221 / B222 / B231 / B232Pneutrol International Ltd are Platinium Distributors for ASCO NumaticsContactus:5CaulsideDrive,Antrim,NorthernIreland,*************************************************:+44(0)2894481800DIMENSIONS (mm), WEIGHT(kg)TYPE 05:TYPE 06:Aluminium, epoxy coated / AISI 316 SS NF / WSNF: EN/IEC 60079-1, 60079-31Epoxy encapsulatedPV: EN/IEC 60079-18, 61241-18327 B 021 / B022 / B031 / B032 / B121 / B122 /327B131 / B132 / B221 / B222 / B231 / B232327B001 / B002 / B011 / B012ABC DEFG H KJ1223Ø5,52741159L1/2 NPTABCD EF G HKJ1223Ø5,52741LTYPE 07:Epoxy encapsulatedEF and EV: NEMA type 7, 9 / ICS-6 ANSI327H021 / H022 / H031 / H032ABCD EF GHKJ1223Ø5,52741type prefix/option power level A B C D E F G H J K L M N weight 01SC BP 45302479138155918550305527671,20 kg 02SCMP/RP 5030249814995915633552786-1,30 kg 03WP , WS, EM, WSEM BP 7730249815512081552786---1,20 kg 04WP , WS, EM, WSEM MP/RP 77302410115812081552789---1,30 kg 05NF , WSNF BP/MP/RP 97302412510254558817627113--2,70 kg 06PV BP 45302486137726745552774--1,20 kg 07EF , EVBP503024871387751552775---1,20 kgPneutrol International Ltd are Platinium Distributors for ASCO NumaticsContactus:5CaulsideDrive,Antrim,NorthernIreland,*************************************************:+44(0)2894481800EXHAUST PROTECTOR ORDER NUMBERS¼ISO 228/1brass/nickelB-MV110014NPT B-PV110014ISO 228/1stainless steelB-VX110014NPTB-PV110014 InoxEXHAUST PROTECTOR213SECTIONAL DRAWINGExecution : Reduced Power TamperproofPneutrol International Ltd are Platinium Distributors for ASCO NumaticsContactus:5CaulsideDrive,Antrim,NorthernIreland,*************************************************:+44(0)2894481800。
外贸函电提纲

⏹第一、词汇互译(20个10分)⏹第二、选择(30分)⏹第三、介词填空(10分)⏹第四、句子互译(25分)⏹第五、信函填词(10分)⏹第六、情景写作(15分)一.词汇部分1.询盘enquiry 具体询盘Specific enquiry 一般询盘General enquiry对某产品询盘make an enquiry for sth给某人发某产品的盘make sb. an offer for sth接受/谢绝报盘to accept/decline an offer2. 实盘firm offer实盘是发盘人在一定期限愿按所提条件达成交易的肯定表示。
实盘的表达法:The offer is firm(good/open/valid) for 3 days.发盘有效期为3天。
The offer is firm(good/open/valid) until October 5.发盘10月5号之前有效。
The offer is firm subject to your reply by 5 p.m., our time, Friday, October 3.10月3日星期五我方当地时间下午5点前收到你方答复为准。
3. 虚盘non-firm offer:是发盘人所作的非承诺性的表示。
该发盘有效是带前提条件的。
虚盘的表达:Subject to our final confirmation以我方最后确认为准Subject to the goods being unsold以货物未售为有效Subject to prior sales以先售为条件quotation & offer前者一般只包括price, commodity, quantity而后者还包括specification, packing, shipment, payment。
所以前者称为报价,而后者称为报盘4. 产品目录Product catalogue5. 价格单Price list/sheet6.保留/参考/免费样品retained sample/ sample for reference/free sample ; sample free of charge7.图文并茂的目录illustrated catalogueif you are interested, we will send you a sample and illustrated catalogue free of charge.8. 商会Chamber of Commerce9.向…开汇票Draw a draft on sb.10.即期汇票Sight draft11.60天远期汇票Draft at 60 days’ sight12.分期付款payment by installment13.货到付款cash on delivery (COD)14.预付款Pay in advance15.下订金Down payment16.进/出口许可证Import/export license17.申请出口许可证apply for an Export License18.不可议付的单据non-negotiable documents19.财务状况/资信financial standing/credit and reputation20.没有库存out of stock21.有库存in stock22.适中的/合适的/可行的价格at moderate/reasonable/workable price23.物美价廉high quality, low price24.一式两份in duplicate25.一式三份In triplicate26.一式……份in…copies27.单独海损particular average28.共同海损General average29.水渍险With particular average (WPA)30.一切/战争险All Risks/ War Risk31.仓至仓条款warehouse to warehouse clause(W/W clause)32.执行订单Fulfill/execute/honor an order33.未完成订单backlog/back order34.适合海运的包装packing suitable for sea voyage/ocean transportation35.推销promote the sale of…Promotion36.提单Bill of Lading37.倒签提单antidated B/L38.特快邮寄express mail39.另函邮寄Under separate cover/ by separate mail40.唛头shipping markThe shipping mark is always at the seller’s option.41.截止时期deadline/due time/ expire二.句子部分1、We shall appreciate it if you will do…如你能做某事,我方将不胜感激。
外贸英语900句

外贸英语900句之佣金CommissionHe came to China to hold a talk about the commission for his new business. 他来中国是洽谈有关生意中的佣金问题。
Usually a 1% commission is given to our agent. 一般情况下,我们给代理商百分之一的佣金。
We'll give you a 3% commission on every transaction. 每笔交易我们都付给百分之三的佣金。
We expect a 5% commission, of course.当然,我们希望能得到百分之五的佣金。
We're usually paid with a 5% commission of the amount for every deal.对每笔交易的成交量,我们通常付给5%的佣金。
Our agents in other areas usually get a 3-5% commission.我方其他地区的代理通常得到3-5%的佣金。
We can get 4.5% commission if 10,000 cases are ordered.如果订1万箱,我们可以得到4.5%的佣金。
The commission from our corporation is very favourable.我们公司给的佣金很优惠。
The above price includes your commission of 2%.上述价格包括百分之二的佣金在内。
The above price excludes your commission.上述价格不包括佣金在内。
This amount includes all commission.这一数字包括所有佣金在内。
What about the commission? 佣金是多少?Our quotation is subject to a 4% commission.我方报价包括百分之四的佣金在内。
catalogue

Ⅰ.Company ProfileJiangsu Sunhome New Energy Co.,Ltd is one of the top professional manufactures in China since 1998. We engage in research,development and application of solar energy products. We are also an excellent exporter and have established long term relationships with many overseas customers. Sunhome products could perform under all weather conditions. Therefore, our products are sold to more than 76 countries and regions such as Europe, America, Australia, Africa and Southeast Asia, and so on.Our products are produced under advanced equipments with top raw materials. Full-time strict quality control covers all steps of the production process and make sure no finished goods with manufacturing fault.We provide timely after-sale service and solar water heater technology consultant. Sunhome closely follows the steps of the developed counties to research more high-tech solar products to meet the Environment-Friendly and energy-saving.Sunhome solar product has been produced according to European EN 12975 standards. And we have already been awarded ISO9001,ISO14001, CCC and CE certifications.We are experienced in offering OEM service to different customers from many countries. We able to produce any Solar Water Heater according to your detailed specifications.All enquiries are welcome.Ⅱ.Solar Collector1.Heat Pipe Solar Collector●Used in split solar heating system for water heating, Solar collectors with different quantity of vacuum tube can be assembled with a water tank of different capacity.●Perfectly designed, suitable for any architectural style, and harmoniously integrated with owner’s building.●Collector can be installed in a single house as well as a commercial building with a centralized hot water system!●The collector’s integrated and modularized design is optimized for both installation and operation.●Economical, affordable, energy saving, environmentally friendly!●Models available:SHHPC58 and SHHPC47 series with required no of tubes Characteristics:1. Easy installation Quick start2. Connected to tap water, working under pressure3. Average daily heat efficiency> 60%4. Vacuum tube separated from water, high thermal stability, no tube blast5. No water running in the vacuum tube, this eliminates the low heat transfer efficiency of water6. Collectors can be connected either in series or in in parallel to increase utilization and flexibility of the installation.7. Single broken vacuum tubes do not affect the operation of the remaining system.8. water jackets protect the rubber rings and dust-proof rings from aging and falling off9. The high-tech treated vacuum tube and super heat pipe release the pressure on proper time10. Waterless vacuum tubes also solve any issues related to calcification of the tubes and the associated reduction in efficiency.◆Technology:Model Type SHHPCManifold casing material Aluminum painted un-oxygen layerFrame material (Aluminum or Stainless Steel or Galvanized Steel)and painted LayerHeader pipe material CopperHeat pipe material CopperInsulation Polyurethane 55mmRubber seals and rings UV stabilized high temperature silicon rubber Test pressure 9 barCollector mounting Plane roof/slope roofAngle of operation 10℃-80℃Inlet Outlet Φ22 or 3/4 inch male◆ Specifications: Heat pipe MODELLigthing (m 2)diameterlength No. Supply hot water(L/ ℃ ) 20/40" containerGW KGSHHPC47/12 1.26 12 70/60 133/276 28 SHHPC 47/18 1.80 18110/60 120/249 42 SHHPC 47/20 2.10 20 125/60 110/227 46 SHHPC 47/30 3.15 Φ47mm1500mm30 180/60 76/158 69 SHHPC 58/12 1.73 12 110/60 118/244 40 SHHPC 58/18 2.57 18150/60 84/175 60 SHHPC 58/20 2.88 20 175/60 77/160 64 SHHPC 58/304.32Φ58mm 1800mm30260/6052/106982.U Pipe collectorThe liquid (usually a glycol-water antifreeze mixture) ) in the U pipe heats up, and conducts the heat energy to the water inside the storage tank through plate exchanger or internal spiral coils.Feature:1.Can operate with water pressure up to 6 bar;2.Can be combined with existing energy source3.Storage do not need be installed above the collector◆Specifications:Model SHUPC58/12SHUPC58/15SHUPC58/18SHUPC58/20 Type of Class Tubeø 58 x 1800mmNumber of Tube12 1518 20U Pipe copperHeader tuber copperInsulation Polyurethane or Rock woolFluid Type pure water or 50/50 propylene glycol and water mixtureTested Pressure10Bar10Bar10Bar10BarSystem Pressure6Bar6Bar6Bar6BarCut Lenth of≥50%≥50%≥50%≥50% efficiencyLigthing Area(m²) 1.71 2.14 2.57 2.86Absorb Area(m²)0.99 1.24 1.48 2.03Packing Demension2050X1160X1102050X1326X1302050X1556X1302050X1726X130 3.Flat Plate Solar CollectorSpecial Anodized aluminum alloy frame to ensure handsome appearance and can accepthigh pressure without leakageOperation Temperature -33℃~120℃Patterned temper glass or low iron temper glass (4mm thickness) is not easy broken withvery high transmission and low emission Black chrome or Magnetic blue sputtering coating has very higher absorption rate to ensure the high efficiency.FOB Shanghai portMODEL Lighting (㎡) No. capacity FP-Collector M-Collector BT-Collector SHFP150 2 1 150L USD230 USD415 USD439 SHFP200 2 1 200L USD298 USD476 USD509 SHFP250 4 2 250L USD378 USD 748 USD852 SHFP300 42300LUSD383USD846USD950SHFPC-2.02(solarkeymark certificated)DESCRIPTIONSize(mm)out line Copper riser tubes Copper header Copper Absorber Fin Surface coating Insulation material FrameFrame colorGlassSealing profile Backing sheet 2000 x 1010x 95mmØ10mm x0.5mm 8pcsØ22 x 0.6mm 2 pcs125mm wide, 0.15mm thickBlack chrome50mm Glasswool, 24KAluminum alloy in 1.3mm thick bronzed, white color, black3.2mm tempered & patterned glass with transmission 92% (anti-reflection) EPDMaluminium material 0.5mmM Collectors (Model:SHFPC-2.0M) AbsorberTypeAbsorber fin material Absorber fin dimensions Sputtered surfaceFeatureAbsorptivityEmittance Flat plate tubeCopper1,970mm×970mmBlack chromium,having selective surface decalescenceAbsorptivity & Emittanceare according to BC091α=0.93(±0.05)ε=0.12(±0.02)Tube ArrayRiser to heat layer joint Header to riser joint Header material Header sizeRiser materialRiser sizeNumber of risers Collector socket material Supersonic melting solderCopper Silver solderType C-copper tube, to AS 1432-1973 Φ 25mm OD, 0.71 mm wall thickness Type C-copper tube, to AS 1432-1973 Φ 12 mm OD, 0.40 mm wall thickness 7Free machining brassCollector socket thread size Maximum torque Connection pip size 20mm(3/4” BSP) 0.03 kN-m19.1mm OD ( 3/4”) Weights & Measures Weight empty Weight fullStructural pressure test 38kg 40kg 800kPaBT Collectors (Model:SHFPC-2.0BT) Absorber TypeAbsorber fin material Absorber fin dimensions Sputtered surfaceFeatureAbsorptivity EmittanceFlat plate and tube Copper1,970mm×970mmTINOX ® high selectivity coating,Made in GermanyAbsorptivity&Emittance are according to BC091 α=0.95(±0.05) ε=0.04(±0.02)Tube ArrayRiser to heat layer joint Header to riser joint Header material Header size Riser material Riser sizeNumber of risersCollector socket material Collector socket thread size Maximum torque Connection pipe sizeSupersonic melting solder Copper Silver solderType C-copper tube, to AS 1432-1973 Φ 25mm OD, 0.71 mm wall thickness Type C-copper tube, to AS 1432-1973 Φ 12mm OD, 0.40mm wall thickness 7Free machining brass 20mm(3/4“BSP) 0.03 Kn-m19.1mm OD ( 3/4“) Weights & Measures Weight empty Weight fullStructural pressure test38kg 40kg 800kPa4.All Glass Vacuum Tube Solar CollectorFeatures:Reliable,efficient,Twin-Glass Vacuum tube Easy plug-in installation and Features: An economical solutionCould be either vertically or horizontally positionedEspecially suit large commercial or industrial applications, such as farm, restaurant, hotel, factory,etc.frame : Imported color steel and aluminum-zinc plated steel, coated with hi-techcorrosion-resistant layerAbsorbing Areavacuum tubeMODEL(m 2)diameter length tubeSHGTC47/60 6.00 Φ 47mm 1500mm 60 SHGTC58/507.14Φ 58mm1800mm 50Ⅲ.Solar Water Heater1.Direct Thermosiphon solar system1).Features●Inner tank: Food Grade Stainless Steel(SUS304/2B) by argon protect welding;●Outer shell: Galvanized Steel coated anti-corrosion layer or stainless steel●Insulation layer: 50-60mm import polyurethane integral foaming●Frame:Galvanized Steel coated with anti-corrosion layer, both installed on inclined and flat roof.●Vacuum tube:47*1500mm and 58*1800mm with AL/N/AL selective surface or Cu-Ss-Al●High Pressure Cold Water In:6 bar cold water to tank from Feeder or Electric Auto Valve.●Automatic Heating Element free ●1% spare parts are free ●5 years quality warranty ●All installation document are freevacuum tubeMODEL Lighting(m 2 ) diameter length No. Cubage (L) GW (kg) Qty.per20'/40' Container SHDTS47/18 1.89 Φ 47mm 1500mm 18 100 62 60/116 SHDTS47/20 2.10 Φ 47mm 1500mm 20 111 68 56/108 SHDTS47/24 2.52 Φ 47mm 1500mm 24 133 76 47/91 SHDTS47/303.15Φ 47mm 1500mm 301668634/65vacuum tube MODEL Lighting(m 2) diameter length No . Cubage (L) GW (kg) Qty.per20'/40' Container SHDTS58/18 2.59 Φ 58mm 1800mm 18 150 84 41/79 SHDTS58/20 2.88 Φ 58mm 1800mm 20 165 90 37/71 SHDTS58/24 3.46 Φ 58mm 1800mm 24 200 110 32/61 SHDTS58/304.32Φ 58mm 1800mm 3025013025/48Quality Control >>>2.Indirect Thermosiphon systemsThermosiphon solar collectors provides mains pressure pre-heating via a high efficiency copper coil heat exchanger located within the solar collector tank. The way in which the Mains Pressure solar collector heats water is the same as the Non pressure solar collector. Rather than using the water in the tank directly, as the Non pressure does, the type uses a 45 ~60m copper coilSpecificationCopper Coil Heat Exchanger SpecificationsHE Material 14mm×1.0mm copper pipeHE Surface Area 2.5m²for 30 tube water heaterHE Testing Pressure 9 barHE net weight 22kg for 30 tube water heaterQty.per20'/40' Container MODELLighting vacuum tube(m2)diameter length tubeSHITS58/20 2.88 Φ 58mm 1800mm 20 32/65SHITS58/24 3.46 Φ 58mm 1800mm 24 30/62SHITS58/30 4.32 Φ 58mm 1800mm 30 24/503.High Pressure Compact Solar Water HeaterSolar collector evacuated tubes collect and convert sunshine energy into thermal energy, which is transferred to the central heat pipes in the tubes through the aluminum fins bridging the tube inner surfaces and the heat pipes. The copper heat pipes have tiny amount of purified water sealed in them at depressurized condition. When heated, the water inside the heat pipes vaporizes at low temperature (about 30˚ C). The vapor (steam) rises to the pipe tips inserted into the water contained in the tank. Vapor is cooled downand becomes condensate falling to the bottom of the pipes. By continuously circulating this way, heat is carried from outside to the water inside the tank.●Heat Pipe Plus Vacuum Tube structure, no any water in tube, if one tube broken, no leakage●High pressure storage tank(Testing pressure=9 bar)●Highly efficient heat pipe technology●No sealing rubber is needed and hence no leaking problem●Easy plug-in installation●Anti-freezeInner Tank304 Stainless steelOuter Shell of Tank Galvanized steel Sheet, Surface plastic painting Supporting Frame Galvanized steel Sheet, Surface plastic painting Insulating Layer Foaming polyurethane, Thickness:55mmWorking Pressure Normal working pressure: 6bar Test pressure: 9bar Electric Booster 1500WAbsorb Area Heat pipeTankcapacityMODEL(m2)diameter length No.(L)Qty.per20'/40' ContainerSHPTS58/18 2.59 Φ 58mm 1800mm 18 150 41/79 SHPTS58/20 2.88 Φ 58mm 1800mm 20 165 32/65 SHPTS58/24 3.46 Φ 58mm 1800mm 24 200 30/62 SHPTS58/30 4.32 Φ 58mm 1800mm 30 250 25/50Ⅳ.Active Solar Water Heater Systems1.Active Open Loop Solar Water Heater SystemsAn Open Loop Water Heating System provides many advantages It is the simplest and typically the least expensive active system to install. There is no heat exchanger, which allows efficient heat transfer directly to the water. The system Operates at standard line pressure. When there is not enough energy for sun, an electrical back up element will be automatically switched on by controller.1).Models availableHeat pipe solar collector ModelCubage(L)Diameter(mm)Length (mm) No. Lighting (m ²) SHOLS100 100 47 1500 20 2.22 SHOLS200 200 58 1800 20 3.00 SHOLS300 300581800304.292).Systems Running Principle:1. Solar Collector 5. Tempering Valve 9. Circulating Pump2. Manual Air Valve 6. Collector Return 10.Roma Valve3. Hot Water to Taps7.Collector Supply11. DHW Electric Tank4.Cold Feed8. Non Return Valve12. Immersion Heater2.Active Closed Loop Solar Water Heater SystemsA 50/50 propylene glycol and water mixture from the collectors through a coil of pipe in the solar tank, and then is pumped back through the collectors. The potable water is warmed by heat transfer through contact with the pipe. These systems are pretty much the only choice in very cold climates. When there is not enough energy for sun, an electrical or gas back up element will be automatically switched on by controller.1). Feature:● Simple Installation,No Maintenance,Effective operation● Easy Retrofitting To Existing systems●Suitable for single and multiple solar heating Application systems,●Preferred option for extremely cold areas and questionable water quality.● Incoming potable water is routed to the solar storage tank● Porcelain Enemal or SUS304 Stainless Steel Storage Tank With Electrical or gas Back Up●Double-walled Copper Coil heat exchangers in storage tank prevent contamination of household water.2).High pressure tank specification:Items 100L 150L 200L 250L 300L 400L 500Linner vessel diameter φ368 φ438 φ542 φ613 water tank dimension φ450 φ520 φ620 φ710 material and thickness ofthe inner vesselBTC340R 1.8 BTC340R 2.0 BTC340R 2.5material and thickness ofthe shellgalvanized sheet 0.5insulation thickness 40 40 40 40 40 50 50 Surface area heatexchanger top(m2)0 0 0.4 0.4 0.4 0.5 0.5Surface area heatexchanger bottom(m2)0.6 0.6 0.6 0.6 0.7 0.8 0.8installation size of waterpipeNPT3/4"rated heating power 1.5KW 2.5working pressure 0.7MPaOveralldimension(references) φ450×1105 φ450×1570φ520×1530φ620×1280φ620×1530φ710×1580φ710×1715Packing case size 480×480×1200 480×480×1665550×550×1625655×655×1375655×655×1625740×740×1675740×740×1800Weight(references)(Kg)46 58 68 75 95 112 122 Note: inner tank can be made of sus304/2b with thickness from 1.5mm to 2.0mm3).Systems Specifications:Heat pipe or U Pipe CollectorModelTank CapacityΦ58X1800No. Work StationSHCLS150S 150L Φ58X1800 24(1 collector with24 tubes) SHCLS200S 200L Φ58X1800 30(1 collector with 30 tubes) SHCLS300S 300L Φ58X1800 30+20(2 collectors)SHCLS400S 400L Φ58X1800 30X2(2 collector for 30 tubes) SHCLS500S 500LΦ58X180030X2+20X1(2 collector with 30 tubes, and 1 collector with 20 tubes)A circulating unit system that gather controller and pump station4).Systems Running Principle:1. Collector7. Check Valve13. Pressure Gauge2. Collector Sensor8. Hose Bibs for Filling and Draining14. Collector Supply3. Manual Air Valve9. Expansion15. Heat Exchange Coil4. Hot Water to Taps10. Air Scoop & Air Vent16.Solar Storage Tank5 .Tempering Valve11. Circulating Pumb17. Immersion Heater6. Collector Return12. Pressure Relief Valve18.ControllerⅤ.Application1). Close loop system with electrical/gas back upClosed Loop Solar Heating Systems are suitable for single and multiple solar heating Application systems, e.g. domestic solar water heating, solar water heating hot tub, solar Swimming pool heating or solar space heating systems. The Closed Loop Solar Systems suitable for areas with questionable water quality and all climate conditions. The Closed Solar Heating Systems are the preferred option for extremely cold areas. When there is not enough energy for sun, an electrical or gas back up element will be automatically switched on by controller.2).Pool HeatingIf you have taken steps to retain your pool’s heat but are still not happy with your heating bills, or if you plan to install a new pool, a solar pool heater may be a goodinvestment. Such heating systems are one of the most cost-effective applications of solar energy. It is relatively simple to integrate a solar water heater since most pools require a pump, filter, and plumbing.With a solar energy system, the pool’s water is pumped through the filter and then through a solar energy collector(s) instead of directly back to the pool. The sun heats the water in the collector(s) before it returns to the pool.If you add a solar heater, you may need a pump larger than your present one, or a separate, smaller pump to pump the pool’s water to and through the solar collectors.Adding any heater, solar or otherwise, will preclude selecting the smallest pump.Nevertheless, you also may reduce pumping time to help cut costs.3).Space-HeatingThe solar collector System is capable of contributing significantly to space heating requirements in many areas. The best use for solar energy is to heat a building by radiant under floor hydraulic heating, which requires water at a temperature of around 60C. This system usually uses a concrete floor slab with special water pipes running through it, to provide a pleasant, even, low temperature radiant heat. The floor slab will also provide heat4).ProjectContact usJiangsu Sunhome New Energy Co., Ltd.Add:No.4 North Taihe Road,Houyu town,Changzhou city,Jiangsu Province, China Tel: 0086-137********Fax:0086-519-83689920E-mail:solarenergy.kevin@。
ProductCatalogue产品目录

Thermal Conductivity
1400 0.7
1.3 4.41 1400
0.6
1.3 3.92 1350
0.6
10Leabharlann 90.80.70.6
0.5
0.4
2.94
2.45
2.45
1.96
1.47
1.17
0.98
1350
1300
1250
1250
1200
1150
1150
0.5
0.4
0.35
0.35
学习改变命运,知 识创造未来
ProductCatalogue产品目录
硅酸钙绝热制品Calcium Silicate Insulating and Refractory Products
名称牌号
指标 体积密度≤g/cm3Bulk density
Al2O3+SiO2 %
Fe2O3 ≤%
体积密度g/cm3Bulk density 规格Specification
颜色Color
硅酸铝纤维异型制品 Abnormity shaped Aluminium silicate fibre products
1000
硅酸铝纤维绳Aluminium silicate fibre rope
硅酸铝纤维针刺毯Aluminium silicate fiber blanket
普通型 Normal 1000
1250
高纯型High Pure 1100 1260
高铝型High Alumina
1200
1350
含锆型Zirconia containing
1350
1450
SMC AC伺服电机驱动器LECSA系列说明书

Do not drop, hit or apply excessive shock to the product. Prevent any foreign matter from entering the product. Use the product within the specified ambient temperature range. If abnormal heating, smoke or a fire occurs in the product, immediately
IEC 60204-1: Safety of machinery - Electrical equipment of machines. (Part 1: General requirements) ISO 10218-1: Robots and robotic devices - Safety requirements for industrial robots - Part 1: Robots. Refer to product catalogue, Operation Manual and Handling Precautions for SMC Products for additional information. Keep this manual in a safe place for future reference.
A regenerative resistor is mounted on the back of the LECSA. The regenerative resistor causes a temperature rise of 100°C relative to the ambient temperature. Fully examine heat dissipation and the installation position before installing the driver.
杜诺尔制造公司60赫兹轻负载顶部驱动包装用户手册说明书

For other service manuals visit our website at:/service_manuals.aspDORNER MFG. CORP .INSIDE THE USA OUTSIDE THE USA P .O. Box 20 • 975 Cottonwood Ave.TEL: 1-800-397-8664TEL: 262-367-7600Hartland, WI 53029-0020 USA FAX: 1-800-369-2440FAX: 262-367-58272100, 2200, 4100, 6200 and MPB Series Top Mount Drive Package for Light Load 60 HzGearmotorsInstallation Maintenance & Parts ManualTable of ContentsIntroduction (2)Warnings − General Safety (3)Product Description (4)Specifications (4)Installation (7)Required Tools (7)Mounting (7)Preventive Maintenance and Adjustment (10)Required Tools (10)Timing Belt Tensioning (10)Timing Belt Replacement (10)Drive or Driven Pulley Replacement (11)Gearmotor Replacement (11)Service Parts (14)2100, 2200, 4100, 6200 and MPB Series TopMount Drive Package (14)4100 Series Adapter Package (15)Gearmotors (15)Return Policy (16)IntroductionUpon receipt of shipment:•Compare shipment with packing slip. Contact factory regarding discrepancies.•Inspect packages for shipping damage. Contact carrier regarding damage.•Accessories may be shipped loose. See accessory instruc-tions for installation.Dorner 2100 Series conveyors are covered by the following patent numbers: 5131529, 5174435, and corresponding patents and patent applications in other countries.Dorner 2200 and MPB Series conveyors are covered by patent number 5174435 and corresponding patents and patent applications in other countries.Dorner 4100 Series conveyors are covered by patent number 3923148 and corresponding patents and patent applications in other countries.Dorner 6200 Series conveyors are covered by patent number 6685009, 5174435, 6109427 and corresponding patents and patent applications in other countries.Dorner’s Limited Warranty applies.Dorner reserves the right to make changes at any time without notice or obligation.IMPORTANTSome illustrations may show guards removed. Do NOT operate equipment without guards.Warnings − General SafetyA WARNINGThe safety alert symbol, black triangle with white exclamation, is used to alert you to potential personal injury hazards.Climbing, sitting, walking or riding on conveyor will cause severe injury.KEEP OFF CONVEYORS.DO NOT OPERATE CONVEYORS IN ANEXPLOSIVE ENVIRONMENT.Hazardous voltage will cause severe injury or death.LOCK OUT POWER BEFORE WIRING.A WARNINGGearmotors may be HOT.DO NOT TOUCH Gearmotors.AWARNINGExposed moving parts can cause severe injury.LOCK OUT POWER before removing guards or performing maintenance.A WARNINGDorner cannot control the physicalinstallation and application of conveyors. Taking protective measures is the responsibility of the user.When conveyors are used in conjunction with other equipment or as part of a multiple conveyor system, CHECK FOR POTENTIAL PINCH POINTS and other mechanical hazards before system startup.A WARNINGMPB Series Conveyors are not reversible. Reversing creates pinch points which can cause severe injury.DO NOT REVERSE MPB SERIES CONVEYORS.Product DescriptionRefer to Figure 1 for typical components.Figure 1SpecificationsGearmotor Mounting Package Models:Example:* See “Ordering and Specifications” Catalog for details.Table 1: Gearmotor SpecificationsA ConveyorB Mounting BracketC GearmotorD Belt T ensionerE CoverF Timing BeltG Drive Pulley HDriven PulleyCBED FHGASingle PhaseDC Variable Speed Output Power 0.03 hp (0.025 kw)0.06 hp (0.04 kw)Input Voltage 115 Volts A.C.130 Volts D.C.Input Frequency 60 Hz N/AFull Load Amperes 0.49 Amperes 0.48 Amperes Gearmotor Ratios15:1 and 36:118:1 and 60:1SpecificationsTable 2: Belt Speeds for Light Load Fixed Speed Parallel Shaft 60 Hz Gearmotors on 2100, 2200 Gang Drive, 4100 and 6200 Series Conveyors* 115V , 1 phase, non −reversingTable 3: Belt Speeds for Light Load Fixed Speed Parallel Shaft 60 Hz Gearmotors on 2200 Series Conveyors (Excluding Gang Drive)* 115V , 1 phase, non −reversingTable 4: Belt Speeds for Standard Load Fixed Speed Parallel Shaft 60 Hz Gearmotors on MPD Series Conveyors* 115V , 1 phase, non −reversingTable 5: Belt Speeds for Light Load Variable Speed Parallel Shaft DC Gearmotors on 2100, 4100 and 6200 Series Conveyors* 130VDCGearmotors *Belt Speed DrivePulley Driven Pulley Part Number Gear Ratio RPMIn-lbN-m Ft/min M/min 62M036PL4FN 36:14236 4.18 2.4223262M036PL4FN 36:14236 4.112 3.7323262M036PL4FN 36:14236 4.117 5.2322262M036PL4FN 36:14236 4.1247.3442262M015PL4FN 15:110015 1.7298.8323262M015PL4FN15:1100151.74112.53222Gearmotors *Belt Speed DrivePulley Driven Pulley Part Number Gear Ratio RPMIn-lbN-m Ft/min M/min 62M036PL4FN 36:14236 4.113 4.0283262M036PL4FN 36:14236 4.115 4.6282862M036PL4FN 36:14236 4.121 6.4322262M036PL4FN 36:14236 4.1298.8442262M015PL4FN 15:110015 1.73510.7282862M015PL4FN15:1100151.75516.84428Gearmotors *Belt Speed DrivePulley Driven Pulley Part Number Gear Ratio RPMIn-lbN-m Ft/min M/min 62M036PL4FN 36:14236 4.1257.5283262M036PL4FN 36:14236 4.1288.6282862M036PL4FN 36:14236 4.14513.6442862M036PL4FN36:142364.15717.34422Gearmotors *Belt Speed DrivePulley Driven Pulley Part Number Gear Ratio RPMIn-lbN-m Ft/min M/min 62M060PLD3DEN 60:142657.4 1.0−8.2.3−2.5223262M060PLD3DEN 60:142657.4 1.4−12.4−3.6323262M018PLD3DEN 18:113921 2.4 4.8−40 1.5−12323262M018PLD3DEN18:1139212.47−58 2.1−183222SpecificationsTable 6: Belt Speeds for Standard Load Variable Speed Parallel Shaft DC Gearmotors on 2200 Series Conveyors (Excluding Gang Drive)* 130VDCTable 7: Belt Speeds for Standard Load Variable Speed Parallel Shaft DC Gearmotors on MPB Series Conveyors* 130VDCGearmotors *Belt Speed DrivePulley Driven Pulley Part Number Gear Ratio RPM In-lbN-mFt/min M/min 62M060PLD3DEN 60:142 657.4 1.8−14.5−4.5282862M060PLD3DEN 60:142657.4 2.8−23.8−7442862M018PLD3DEN 18:113921 2.46−49 1.8−15282862M018PLD3DEN18:1139212.49−77 2.8−234428Gearmotors *Belt Speed DrivePulley Driven Pulley Part Number Gear Ratio RPMIn-lbN-m Ft/min M/min 62M060PLD3DEN 60:142657.4 2.3−19.7−5.9223262M060PLD3DEN 60:142657.4 3.4−281−8.6282862M060PLD3DEN 60:142657.4 5.3−44 1.6−13442862M018PLD3DEN 18:113921 2.411−94 3.5−28282862M018PLD3DEN18:1139212.416−1485−454428NOTEFor belt speed other than those listed, contact factory for details.InstallationRequired Tools •Hex key wrenches:2.5 mm, 3 mm, 5 mm •Torque wrench Installation Component List:Mounting 1.Typical components (Figure 2)Figure22200 SeriesFigure4I T op Mount AssemblyJ Driven PulleyK CoverL M4 Socket Head Screws (4x)M Timing BeltN KeyO M6 Socket Head Screws (2x)Exposed moving parts can cause severe MPB Series Conveyors are not reversible.Reversing creates pinch points which cancause severe injury.DO NOT REVERSE MPB SERIESKLMIJONQPInstallation6100 SeriesFigure54100 SeriesFigure62100 SeriesFigure7MPB SeriesFigure8 4.Attach mount assembly (Figure 9,item I) with two screws (O). Tighten screws to 80 in-lb (9 Nm).Figure95.Install key (Figure 10,item N).Figure10A WARNINGDrive shaft keyway may be sharp.HANDLE WITH CARE.IOUNRJMInstallation6.Wrap timing belt (M) around driven pulley (J) and drive pulley (R). Install driven pulley (J) onto conveyor shaft.7.Remove cam bearing and spacer (Figure 9,item U). Place the cam bearing and spacer (Figure 11,item U) next to the driven pulley (M). Ensure the flanges of the driven pulley are aligned with the cam bearing. Tighten set screws on driven pulley (J). This will allow for proper belt alignment while conveyor is in use. Install cam bearing and spacer (U).Figure 118.Depending on direction of conveyor belt travel (1 or 2 of Figure 12), position timing belt tensioner (U) as shown. Tension timing belt to obtain 1/8” (3 mm) deflection for 1 lb (456 grams) of force at timing belt mid-point (V). Tighten tensioner screw to 106 in-lb (12 Nm).Figure 129.Install cover (Figure 13,item K) with four (4) screws (L). Tighten to 35 in-lb (4 Nm).Figure 13UMJVV12UULKLPreventive Maintenance and AdjustmentRequired Tools•Hex key wrenches: 2.5 mm, 3 mm, 5 mm•Screwdriver (for terminal box screws)•Torque wrenchTiming Belt Tensioning1.Remove four screws (Figure 14,item L) and remove cover (K).Figure 142.Loosen tensioner (Figure 15,item U).Figure 153.Depending on direction of conveyor belt travel (1 or 2 of Figure 16), position timing belt tensioner (U) as shown. Tension timing belt to obtain 1/8” (3 mm) deflection for 1 lb (456) grams of force at timing belt mid-point (V). Tighten tensioner screw to 106 in-lb (12 Nm).Figure 164.Install cover (Figure 14,item K) with four (4) screws (L). Tighten screws to 35 in-lb (4 Nm).Timing Belt Replacement1.Remove four (4) screws (Figure 14,item L) and remove cover (K).2.Loosen tensioner (Figure 15,item U).3.Remove timing belt (Figure 17,item M).A WARNINGExposed moving parts can cause severe injury.LOCK OUT POWER before removing guards or performing maintenance.LKLUA WARNINGExposed moving parts can cause severe injury.LOCK OUT POWER before removing guards or performing maintenance.NOTEIf timing belt does not slide over pulley flange, loosen driven pulley set screws (Figure 17,item T) and remove pulley with belt. For re-installation, see steps 6 through 9 on page 9.12VVUUPreventive Maintenance and AdjustmentFigure 174.Install new timing belt.5.Depending on direction of conveyor belt travel (1 or 2 of Figure 16), position timing belt tensioner (U) as shown. Tension timing belt to obtain 1/8” (3 mm) deflection for 1 lb (456 grams) of force at timing belt mid-point (V). Tighten tensioner screw to 106 in-lb (12 Nm).6.Install cover (Figure 14,item K) with four (4) screws (L). Tighten screws to 35 in-lb (4 Nm).Drive or Driven Pulley Replacement1.Complete steps 1 through 3 of “Timing Belt Replacement” section on page 10.2.Loosen set screws and remove drive or driven pulley.Figure 183.Complete steps 6 through 9 of “Installation” section on page 9.Gearmotor Replacement1.For single phase motor, unplug power cord from outlet.2.For DC variable speed motor, unplug motor cord at disconnect (Figure 19,item W).A WARNINGExposed moving parts can cause severe injury.LOCK OUT POWER before removing guards or performing maintenance.NOTEIf drive pulley (Figure 18,item R) is replaced, wrap timing belt around drive pulley and complete step 3.RJM TA WARNINGExposed moving parts can cause severe injury.LOCK OUT POWER before removing guards or performing maintenance.A DANGERHazardous voltage will cause severe injury or death.LOCK OUT POWER BEFORE WIRING.RJMTPreventive Maintenance and AdjustmentFigure 193.Remove four (4) screws (Figure 14,item L) and remove cover (K).4.Loosen tensioner (Figure 15,item U).5.Remove timing belt (Figure 20,item M).Figure 206.Loosen two (2) set screws (Figure 21,item T). Remove drive pulley (R).Figure 217.Remove four (4) screws (X) and detach gearmotor.Figure 228.Mount new gearmotor with four (4) screws (X). Tighten to 45 in-lb (5 Nm).9.Replace drive pulley (Figure 21,item R) and tighten setscrews (T).plete steps 6 through 9 of “Installation” section onpage 9.11.Replace wiring:•For a single phase motor, reverse step 1 on page 11.•For DC variable speed motor, reverse step 2 on page page 11.NOTEIf timing belt does not slide over pulley flange, loosen driven pulley set screws (Figure 20,item T) and remove pulley with belt (M). For re-installation, see steps 6 through 9 on page 9.MT RTXNotesService PartsNOTEFor replacement parts other than those shown in this section, contact an authorized Dorner Service Center or the factory.2100, 2200, 4100, 6200 and MPB Series Top Mount Drive PackageService Parts4100 Series Adapter PackageGearmotorsItem Part Number Description1202390M Nut, Cam Follower2450027M Drive Spacer (2100, 6200 Only)450377M Drive Spacer (4100 Only)3450375M Cover Mounting Bracket 4450376M Drive Guard5450026M Light Duty Motor Mount Plate 6450445Spacer, Cam Follower (Fixed SpeedGearmotors only)450195Spacer, Cam Follower (Variable Speed Gearmotors only)7802−046Bearing8807−226Snap −out Plastic Plug9807−952Groove Pin (2100, 4100, 6200 Only)10920545MSocket Head Screw M5x45mm − 15:1 Gearhead (Fixed Speed Gearmotor Only)920555MSocket Head Screw M5x55mm − 36:1 Gearhead (Fixed Speed Gearmotor Only)920416MSocket Head Cap Screw M4x16mm (Variable Speed Gearmotor Only)11980422M Square Key, 0.4mm x 22mm (Fixed Speed Gearmotor Only)912−084Square Key, 0.125” x 0.75” (Variable Speed Gearmotor Only)12920406M Socket Head Screw M4 x 6mm 13920408M Socket Head Screw M4 x 8mm 14920625M Socket Head Screw M6 x 25mm (2100)920622M Socket Head Screw M6 x 22mm (2200) 920618M Socket Head Screw M6 x 18mm(4100)920630MSocket Head Screw M6 x 30mm (6200)15920840M Socket Head Screw M8 x 40mm 16980422M Square Key 4mm x 22mm912−084Square Key, 0.125” x 0.75”(1” Wide Conveyor − 4100 Only)17814-105Timing Belt, 15mm W x 460mm L 814-065Timing Belt, 15mm W x 475mm L 814-101Timing Belt, 15mm W x 500mm L 814-108Timing Belt, 15mm W x 520mm L 18450366MP Driven Pulley, 22Tooth, 12mm bore 450367MP Driven Pulley, 28Tooth, 12mm bore 450368MPDriven Pulley,32Tooth, 12mm bore 19450384MP Drive Pulley, 22T ooth, 10mm bore 450385MP Drive Pulley, 28T ooth, 10mm bore 450386MP Drive Pulley, 32T ooth, 10mm bore 450387MP Drive Pulley, 44T ooth, 10mm bore 450556P Drive Pulley, 22T ooth, 0.5” bore 450556P Drive Pulley, 28T ooth, 0.5” bore 450556P Drive Pulley, 32T ooth, 0.5” bore 450556PDrive Pulley, 44T ooth, 0.5” boreItem Part Number Description1609486Mounting Block 1” (25mm)609487Mounting Block 2” (51mm)609488Mounting Block 3” (76mm)609479Mounting Block 4” (102mm)609480Mounting Block 5” (127mm)609481Mounting Block 6” (152mm)609482Mounting Block 7” (178mm)609483Mounting Block 8” (203mm)609484Mounting Block 10” (254mm)609485Mounting Block 12” (305mm)2613602P Bolt & Flat Washer Assembly 3450374Drive Adapter Plate 4910−126Hex Nut with Lock Washer 5930612MFlat Head Screw, M6 x 12mmItem Part Number Part Description162M036PL411FN Gearmotor, 0.03 hp, 115 Volts,42RPM, 60 Hz, 1-Phase, 36:162M015PL411FN Gearmotor, 0.03 hp, 115 Volts, 100 RPM, 60 Hz, 1-Phase, 15:162M060PLD3DENGearmotor, 0.06 hp, 130 Volts, 42 RPM, DC, 60:162M018PLD3DENGearmotor, 0.06 hp, 130 Volts, 139 RPM, DC, 18:162M036PL423FN Gearmotor, 0.03 hp, 230 Volts, 42 RPM, 60 Hz, 3-Phase, 36:162M015PL423FN Gearmotor, 0.03 hp, 230 Volts, 100 RPM, 60 Hz, 3-Phase, 15:162M036PL423EN Gearmotor, 0.03 hp, 230 Volts, 7-42 RPM, 60 Hz, 3-Phase, 36:162M015PL423ENGearmotor, 0.03 hp, 230 Volts, 17-100 RPM, 60 Hz, 3-Phase, 15:12980422M Key, 4mm x 22mm, 10mm Bore 912−052Key, 1/8” x 5/8”, 1/2” BoreDorner Mfg. Corp. reserves the right to change or discontinue products without notice. Allproducts and services are covered in accordance with our standard warranty. All rights reserved. © Dorner Mfg. Corp. 2010DORNER MFG. CORP.975 Cottonwood Ave., PO Box 20Hartland, WI 53029-0020 USATEL 1-800-397-8664 (USA)FAX 1-800-369-2440 (USA)Internet: Outside the USA:TEL 1-262-367-7600FAX 1-262-367-5827Return PolicyReturns must have prior written factory authorization or they will not be accepted. Items that are returned to Dorner without authorization will not be credited nor returned to the original sender. When calling for authorization, please have the following information ready for the Dorner factory representative or your local distributor:1. Name and address of customer.2. Dorner part number(s) of item(s) being returned.3. Reason for return.4. Customer's original order number used when ordering the item(s).5. Dorner or distributor invoice number (if available, part serial number).A representative will discuss action to be taken on the returned items and provide a Returned Goods Authorization (RMA)number for reference. RMA will automatically close 30 days after being issued. To get credit, items must be new and undamaged. There will be a return charge on all items returned for credit, where Dorner was not at fault. It is the customer’s responsibility to prevent damage during return shipping. Damaged or modified items will not be accepted. The customer is responsible for return freight.Conveyors and conveyor accessoriesStandard catalog conveyors 30%MPB, 7200, 7300 Series, cleated and specialty belt50%AquaGard & AquaPruf Series conveyors non-returnable itemsEngineered to order products case by caseDrives and accessories30%Sanitary stand supports non-returnable itemsPartsStandard stock parts30%Plastic chain, cleated and specialty belts non-returnable itemsReturns will not be accepted after 60 days from original invoice date. The return charge covers inspection, cleaning, disassembly, disposal and reissuing of components to inventory. If a replacement is needed prior to evaluation of returned item, a purchase order must be issued. Credit (if any) is issued only after return and evaluation is complete.Dorner has representatives throughout the world. Contact Dorner for the name of your local representative. Our Customer Service Team will gladly help with your questions on Dorner products.For a copy of Dorner's Warranty, contact factory, distributor, service center or visit our website at .For replacement parts, contact an authorized Dorner Service Center or the factory.。
西门子低压电机启动器SIRIUS IEC启动器说明书

15LOW VOLTAGE MOTOR STARTERS POWER PRODUCTLow Voltage Motor StartersSiemens SIRIUS IEC StartersThe SIRIUS IEC Starter is the new generation of IEC HP rated magnetic starters, designed to meet and exceed today’s market requirements for HP rated starters.The new SIRIUS Starters take advantage of the reliability of the SIRIUS line of contactors and overload relays in addition to the new line of SIGNUM 3SB3 22mm pilot devices as the standard control device.As evident in the design and size, all efforts were put in place to offer a new line of starters that exceeds the performance of the previous generation. The SIRIUS IEC Starters line also offers more price flexibility in the very competitive starters market. SIRIUS Starters Features:b CSA approvedb100HP, 600V maxb Standard 2NO+2NC auxiliary contactsb Ambient 60°C on contactorsb Fast and simple 3-prong overload contactor connection: no coil extension requiredb Standard primary and secondary fusing on control transformersb Standard Metal 22mm SIGNUM Control DevicesContentsSelection 15-2 Full V oltage Non-ReversingNEMA 4X Non-Metallic 15-4 Full Voltage Metallic 15-8 Non - Combination 15-9 Circuit Breaker Combination 15-10 Fusible Switch Combination and Non-Fusible Starter 15-11 Full V oltage ReversingGeneral 15-12 Non - Combination 15-13 Circuit Breaker Combination 15-14 Fusible Switch Combination and Non-Fusible Starter 15-15 T wo Speed StartersGeneral 15-16 T wo Windings, Constant or Variable T orqueNon - Combination 15-17 Circuit Breaker Combination 15-18 Fusible Switch Combination and Non-Fusible Starter 15-19 Single Winding, Constant or Variable T orqueNon - Combination 15-20 Circuit Breaker Combination 15-21 Fusible Switch Combination and Non-Fusible Starter 15-22 Overload Relay Chart 15-23 Factory ModificationsSelection 15-24 SIRIUS Pre - Assembled Starter Packages 15-29 Dimensions 15-321NO auxiliary contact for starters up to 10HP at 600V.15Siemens Canada Limited Power Product Catalogue15-215L O W V O L T A G E M O T O R S T A R T E R SSIRIUS HP Rated Magnetic StartersSelectionSiemens Canada Limited Power Product Catalogue 15-315LOW VOLTAGE MOTOR STARTERSA.C. Magnetic StartersSelectionSiemens Canada Limited Power Product Catalogue15-4Full Voltage Non-ReversingNEMA 4X Non-MetallicSelectionLate 2017Non-Combination - Up to 10HP - 600VSiemens Canada Limited Power Product Catalogue 15-515LOW VOLTAGE MOTOR STARTERSFull Voltage Non-ReversingOverload Range and Short Circuit RatingsSelectionNote :FLC: as per CSA 22.2 No.14-13 table 18A.For all the 3RU2116 Overloads, the contactor can be use are 3RT2017, 3RT2018, 11 Amps max. in the enclosureSiemens Canada Limited Power Product Catalogue15-6Late 2017Full Voltage Non-ReversingNEMA 4X Non-MetallicSelectionNon-Combination - Up to 10HP - 600VSiemens Canada Limited Power Product Catalogue 15-715LOW VOLTAGE MOTOR STARTERSFull Voltage Non-ReversingOverload Range and Short Circuit RatingsSelectionNote :FLC: as per CSA 22.2 No.14-13 table 18A.For all the 3RU2126 Overloads the contactor can be use are 3RT2027, 3RT2028, 22 Amps max. in the enclosure.Siemens Canada Limited Power Product Catalogue15-815L O W V O L T A G E M O T O R S T A R T E R SFull Voltage Non-ReversingFull Voltage MetallicSelectionGeneralDescriptionSiemens full voltage non-reversing type starters are designed for full voltage across-the line starting of single or 3-phase squirrel cage motors. They also can be used as the primary control of wound rotor motors.Combined with short circuit protection, FVNR starters are also offered as combination starters.b F usible disconnect type complete with Form II, Class C fuse clips, or as an option, Form I, Class J fuse clips.b C ircuit breaker type or as Non-Fusible Controller.FVNR starters are available up to 100HP , 600V AC, EEMAC type 1 or 12 sheet metal enclosed. They are an assembly of the proven 3RT contactors and the exclusive 3RU bimetal overload relays.HP Rated StarterSiemens Canada Limited Power Product Catalogue 15-915LOW VOLTAGE MOTOR STARTERSFull Voltage Non-ReversingNon-CombinationSelectionThe type numbers in the selection table specify a 120V 60 Hz coil. If a different coil voltage is required, change the “K” (7 digit) as per Coil Suffix Table above.Siemens Canada Limited Power Product Catalogue15-1015L O W V O L T A G E M O T O R S T A R T E R SFull Voltage Non-ReversingReplacement PartsSelectionThe type numbers in the selection table specify a 120V 60 Hz coil. If a different coil voltage is required, change the “K” (7 digit) as per Coil Suffix Table above.F actory will automatically select the circuit breaker based onstandard or given motor full-load current and the following: - Continuous-current rating of a minimum 115% of motor full-load current.- Trip-setting position is 11 times motor full load current.Circuit Breaker CombinationSiemens Canada Limited Power Product Catalogue 15-1115LOW VOLTAGE MOTOR STARTERSFull Voltage Non-ReversingFusible Switch Combination and Non-Fusible StarterSelectionThe type numbers in the selection table specify a 120V 60 Hz coil. If a different coil voltage is required, change the “K” (7 digit) as per Coil Suffix Table above.S tarters are suitable for HRC IIC Fuses. Refer to page15-23 for HRC IJ Fuse Clips.Siemens Canada Limited Power Product Catalogue15-1215L O W V O L T A G E M O T O R S T A R T E R SFull Voltage ReversingGeneralSelectionSIRIUS HP Rated Magnetic Starters DescriptionSiemens full voltage reversing type starters are designed for full voltage across-the-line starting and reversing of single or 3-phase squirrel cage motors. They also can be used as the primary control of wound rotor motors.Combined with short circuit protection, FVR starters are also offered as combination starters: b F usible disconnect type complete with Form II, ClassC fuse clips, or as an option, Form I, Class J fuse clips.b C ircuit breaker type or as Non-Fusible Controller.FVR - starters are available up to 100HP , 600V AC in EEMAC type 1 or 12 sheet metal enclosures.FVR - starters are an assembly of the 3RA Reversing Contactor including electrical and mechanical interlock and a 3RU bimetallic overload relay.HP Rated StarterCatalogue No.:Siemens Canada Limited Power Product Catalogue 15-1315LOW VOLTAGE MOTOR STARTERSThe type numbers in the selection table specify a 120V 60 Hz coil. If a different coil voltage is required, change the “K” (7 digit) as per Coil Suffix Table above.Siemens Canada Limited Power Product Catalogue15-1415L O W V O L T A G E M O T O R S T A R T E R SThe type numbers in the selection table specify a 120V 60 Hz coil. If a different coil voltage is required, change the “K” (7 digit) as per Coil Suffix Table above.Siemens Canada Limited Power Product Catalogue 15-1515LOW VOLTAGEMOTOR STARTERSFull Voltage ReversingFusible Switch Combination and Non-Fusible StarterSelectionThe type numbers in the selection table specify a 120V 60 Hz coil. If a different coil voltage is required, change the “K” (7 digit) as per Coil Suffix Table above.Siemens Canada Limited Power Product Catalogue15L O W V O L T A G E M O T O R S T A R T E R STwo Speed StartersGeneralSelectionSIRIUS HP Rated Magnetic Starters DescriptionFull-voltage ac magnetic two speed controllers are designed to control reconnectable squirrel-cage induction motors for operation at two different constant speeds depending on the construction of the motor. Thesecontrollers are available in combination and non-combination types.The speed of an induction motor is a function of the supply frequency and the number of poles of the motor winding. T o obtain different speeds with afixed supply frequency, the number of magnetic poles of the motor must be changed.Characteristics at any speed are similar to those of a single-speed motor. There are two basic methods of providing multiple-pole combinations:Separate-Winding Motors have a separate winding for each speed. This motor construction is slightly moreexpensive, but the controller is relatively simple, and a wide variety of speeds can be selected. Separate winding motors with delta connected motor windings require one corner to be opened on each unused winding.Consequent-Pole Motors have a single winding for two speeds. Extra winding taps are brought out for reconnection for different number of stator poles. While the motor costs less, the controller is more complicated, and speed range is limited to a 2-to-1 ratio.T orque CharacteristicsMulti-speed motors are divided into three application groups:Constant T orque - HP output varies directly with speed, while torque remains constant. A constant-torque motor rated 100 HP at 1200 rpm delivers 50 HP at 600 rpm. This type is applicable to conveyors, mills, dough mixers, reciprocating pumps, and other similar loads.Variable T orque - HP varies as a square of speed, while torque varies directly with speed. A variable-torque motor rated 100 HP at 1200 rpm delivers25 HP at 600 rpm. This type is applicable to systems having fan or centrifugal pump characteristics.Constant Horsepower - Motor delivers rated HP at all full-load speeds, while torque varies inversely to speed. This type is applicable to cutting tools, lathes,spindles, etc.Selection and OrderingStarter ratings are based on the maximum HP at the highest speed. Electrical interlocking is furnished on all multi-speed starters to preclude connecting more than one speed winding at the same time. Bothmechanical and electrical interlocking is provided wherever there is a possibility of short circuiting of the line.Standard wiring permits starting the motor on any speed. T o change a running motor to a higher speed, operator presses the desired speed button. T o change to a lower speed, operator must press “stop” button before selecting the lower speed; allowing time for the motor to slow down, this reduces shock on driven machinery and surges on the power system.When control at various speeds is by means of two-wire control devices, such as limit, pressure or float switches,deceleration relays should be used,unless both the motor manufacturer and the machine manufacturer have been consulted.(fuse clips, control & timing relays, metering & protective devices, etc)Catalogue No.:Siemens Canada Limited Power Product Catalogue 15-1715LOW VOLTAGE MOTOR STARTERSTwo Speed StartersNon-CombinationSelectionThe type numbers in the selection table below specify 120V 60 Hz coils. If a different coil voltage is required, change the “K”(7 digit) as per Coil Suffix Table above.Siemens Canada Limited Power Product Catalogue15-1815L O W V O L T A G E M O T O R S T A R T E RS(7 digit) as per Coil Suffix Table above.F actory will automatically select the circuit breaker based onstandard or given motor full-load current and the following: - Continuous-current rating of a minimum 115% of motor full-load current.- Trip-setting position is 11 times motor full load current.Two Speed StartersCircuit Breaker CombinationSelectionSiemens Canada Limited Power Product Catalogue 15-1915LOW VOLTAGEMOTOR STARTERSTwo Speed StartersFusible Switch Combination and Non-Fusible StarterSelectionThe type numbers in the selection table below specify 120V 60 Hz coils. If a different coil voltage is required, change the “K”(7 digit) as per Coil Suffix Table above.Siemens Canada Limited Power Product Catalogue15-2015L O W V O L T A G E M O T O R S T A R T E R STwo Speed StartersNon-CombinationSelectionThe type numbers in the selection table below specify 120V 60 Hz coils. If a different coil voltage is required, change the “K”(7 digit) as per Coil Suffix Table above.15LOW VOLTAGEMOTOR STARTERSThe type numbers in the selection table below specify 120V 60 Hz coils. If a different coil voltage is required, change the “K”(7 digit) as per Coil Suffix Table above.F actory will automatically select the circuit breaker based onstandard or given motor full-load current and the following: - Continuous-current rating of a minimum 115% of motor Two Speed StartersCircuit Breaker CombinationSelection15L O W V O L T A G E M O T O R S T A R T E R STwo Speed StartersFusible Switch Combination and Non-Fusible StartersSelectionThe type numbers in the selection table below specify 120V 60 Hz coils. If a different coil voltage is required, change the “K”(7 digit) as per Coil Suffix Table above.15LOW VOLTAGEMOTOR STARTERSOverload Relay ChartSelection15L O W V O L T A G E M O T O R S T A R T E RSFactory ModificationsPower Line Voltage and Control Circuit OptionsSelectionControl Circuit SelectionNote: Power line voltage is an important data to be known in order to provide a starter properly connected for single phase or three phase load.15LOW VOLTAGE MOTOR STARTERSAdditional Auxiliary ContactsPilot Devices – OperatorsLegend Plates are supplied as standard with OperatorsFactory ModificationsCircuit Breaker Combination, Constant or Variable TorqueSelection15L O W V O L T A G E M O T O R S T A R T E R SFactory ModificationsPower Line Voltage and Control Circuit OptionsSelectionPilot Devices – Operators (continued)Legend Plates are supplied as standard with OperatorsPilot Devices – Indicators15LOW VOLTAGE MOTOR STARTERSPilot LightsLegend Plates and Lens Colours15L O W V O L T A G E M O T O R S T A R T E R SMiscellaneous Options:Specify by suffix and description as required.Append to Catalogue No i.e.: V4AB15K1E5R05C165-Z _ _ _ _ _ _Fuse Clips:All Fusible Disconnect Combination Starters are supplied with Form II C fuse clips as standard.15LOW VOLTAGE MOTOR STARTERSSiemens SIRIUSPre-assembled starter packages are the simple way to order starters :b 50HP , 600V max, combination and non-combinationb Standard 1NO contact up to 10HP , 2NO+2NC contacts from 15-50 HP b Ambient 60˚C on contactorsb Fast and simple 3-prong overload/ contactor connection: no coil extension requiredb Standard primary and secondary fusing on control transformers b Standard Metal 22mm SIRIUS Control DevicesSIRIUS GOLD, SIL VER AND BRONZE Starter Packages offer these standard features:GOLDb 50 VA 600/120V control transformer b 3 pos. selector switch H.O.A. b Pilot light 120V redSIL VERb 50 VA 600/120V control transformer b Start/Stop pushbuttons b Pilot light 120V red BRONZEb No control transformer b No pilot devicesSiemens modular line of quality Motor Control Products meets and exceeds international standards and are built to serve global markets. Here’s why choosing a pakage is the smarter way to select a starter:Saves TimeNo more lengthy navigating through product catalogues! GOLD, SIL VER and BRONZE starters offer and easy 2 step approach to selecting your starter. 1. Select the starter based onHorsepower (HP) and Line Voltage. 2. Select the appropriate overload relay.Then it’s ready to install. All this convenience is now available off your distributor’s shelves.Saves MoneyThis unique solution for the industry’s most popular full voltage non-reversing starters is competitively priced compared to other custom-engineered starters.Saves HassleEase of selection. Off the shelf availability. Competitive pricing. It’s easy to see why GOLD, SIL VER and BRONZE pakages are the ideal solution. For serious performance and serious convenience, take a SIRIUS approach to starters.15L O W V O L T A G E M O T O R S T A R T E RSNon-Combination Starter Package Selection EEMAC T ype 1 EnclosedSiemens Canada Limited Power Product Catalogue 15-3115LOW VOLTAGEMOTOR STARTERSFusible Combination Starter Package Selection EEMAC T ype 1 EnclosedOverload Relay Selection ChartSIRIUS Pre-Assembled Starter PackagesContactors and Contactor Assemblies (Gold, Silver and Bronze)SelectionSiemens Canada Limited Power Product Catalogue15-3215L O W V O L T A G E M O T O R S T A R T E R SFigure 3Magnetic StartersDimensionsSelectionNote : All dimensions shown for reference purpose only. Not to be used for construction purposes.。