E/P REGULATORMODEL NAMEITV1000, ITV2000, ITV3000 series ITV1000, ITV2000, ITV3000 seriesSeriesContentsP1 Safety instructions P2 Handling precautions P3-4 Wiring method P5-6 Setting methodP7 Key locking functionP8 Setting of min. pressure, max. pressure and switch output P9 Mode of switch outputP10 Setting of preset pressure P11 Reset functionP11 Error indicating function P12 Detail setting mode P13 Gain settingP13-14 Sensitivity setting P14 Zero clear P15 Initialize P15-16 LED displayP16URL MANUALCONTENTS CONTENTSThese safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by labels of “CAUTION ” “WARNING ”, or “DANGER ”. To ensure safety, be sure to observe ISO 4414, JIS B 8370 and other safety practices.■Explanation of label△! WARNING WARNING Operator error could result in serious injury or loss of life. △!CAUTION CAUTIONOperator error could result in injury or equipment damage.△!①comp The compatibility atibility of pneumatic equipment is the responsibility of the person who who designs designs designs the pneumatic system or decides its specifications. the pneumatic system or decides its specifications.the pneumatic system or decides its specifications. Since the products specified here are used in various operating conditions, their compatibility for the specific pneumatic system must be based on specifications or after analyses and/or tests to meet your specific requirements. The expected performance and safety assurance will be the responsibility of the person who has determined the compatibility of the system. This person should continuously review the suitability of all items specified, referring to the latest catalog information with a view to giving due consideration to any possibility of equipment failure when configuring a system.②Only trained personnel should operate pneumatically operated machinery andequipment.equipment.Compressed air can be dangerous if an operator is unfamiliar with it. Assembly, handling or repair of pneumatic systems should be performed by trained and experienced operators.③Do not service machinery / equipment or attempt to remove components until safety is confirmed.safety is confirmed.A. Inspection and maintenance of machinery / equipment should only be performed once safetyof personnel and equipment is confirmed.B. When equipment is to be removed. Stop supplied air, exhaust the residual pressure, verify the release of air, turn the power off and confirm safety before performing maintenance.C. Before machinery / equipment is restarted, ensure safety before applying power.④Contact Contact SMC if the product is to be used in any of the following conditions. SMC if the product is to be used in any of the following conditions. SMC if the product is to be used in any of the following conditions.A. Conditions and environments beyond the given specifications, or if product is usedoutdoors.B. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles, medical equipment, food and beverages, recreation equipment, emergency stop circuits, clutch and brake circuit in press applications, or safety equipment.C. An application which has the possibility of having negative effects on people, property, or animals requiring special safety analysis.△!If power to this product is cut off due to a power failure, etc. when it is in a controlled state, residual pressure will be retained temporarily. Handle carefully when operating with output pressure released to the atmosphere, as air will continue to flow out.If supply pressure to this product is interrupted or shut off, while the power is still on, the internal solenoid valve will continue to operate and a humming noise may be generated. Since the life of the product may be shortened, shut off the power supply also when supply pressure is interrupted or shut off.The optional cable connector is a 4 wire type. When the monitor output (analogue output or switch output) is not being used, prevent it from touching the other wires as a malfunction could occur.This product is adjusted for each specification at the time of shipment from the factory. Avoid careless disassembly or removal of parts, as this can lead to malfunction.△!Take the following steps to avoid malfunction due to noise.1)Install a line filter etc. to the AC powerline to reduce / eliminate power supplynoise.2)Avoid malfunction due to noise byinstalling this product and its wiringaway from strong electric fields, such asthose of motors and power line, etc.3)Be sure to implement protective measuresagainst load surge for induction loads(solenoid valves, relays etc.).4)Turn off the power supply beforeinstalling or removing the connector.Please note that the right angled cable connector does not rotate and is limited to only one entry direction.△!① Proceed carefully, as incorrect wiring can cause damage. ② Use DC power supply with sufficient capacity and a low ripple. ③ Turn off the power supply to remove and insert the connector. ④ Never turn the right angled type connector as it is not designed to turn.Note) The wire color isfor when optional cable is used.Wiring Wiring diagram (diagram (diagram (Power supply and input signal)Power supply and input signal)Power supply and input signal)Current/Voltage type(ITV※0※※-0、ITV※0※※-1、ITV※0※※-2、ITV※0※※-3)Preset input type(ITV※0※※-4)1 Brown Power supply 2 White Input signal 3 Blue GND(COMMON) 4 Black Monitor outputWiring diagram Wiring diagram((Monitor output Monitor output))△!When the monitor output is not being used, prevent it from touching the other wires as this can cause a malfunction.△!① If the incorrect key is pressed or incorrect information is displayed during setting, power must be shut off and the procedure started again.② It is recommended that the settings are changed without supply pressure. The product operates immediately maximum and minimum pressures are set and the S-key is pressed.③ It is recommended that the minimum pressure is output when air is supplied to the inlet, even if the input signal has not been entered.④ Output pressure from this product and state of operation are changed by changing of each setting and function. Each setting and function should be operated by trained and experienced operator.Flow of the setting(Note 1): Please refer to each contents about operation methode.(Note 2): The function of the setting of preset pressure is preset input typeonly.(Note 3): The function of the setting of switch output is switch output typeonly.设置预设压力设置最小压力设置最大压力设置选择输出详细设置增益灵敏度△!The keys are locked after turning the power on and can not be operated. Unlocking the keys(DEFAULT VALUE: 0%)(Note 2): The pressure of less than 0% is not output, even if F_1 is adjustedto less than 0%. (Note 3): F_2 is adjustable in a range from 10 to 120% of the rated value.(DEFAULT VALUE: 100%) (Note 4): Do not input the signal as like output the pressure of more than 100%.Please use in a range of rating. (Note 5): The difference between F_1 and F_2 is adjustable in a range of 10% ofthe rated value.(Note 6): The adjustment like making the relation of F_1>F_2 is not available.设置最小气压、最大气压以及选择输出F 1调整范围在-20%~90%之间如果F 1设置低于0%则无输出F 2调整范围在10%~120%之间不要将输入信号设置像输出信号超过100%,请设置在合理范围F 1和F 2不同在于设定值10%的范围The following operation types are available by setting P_1 and P_2.Note). This function is available for monitor output: switch output type (ITV※0※※-※2 and ITV※0※※-※3). ■ P_1<P_2 : ■P_1≧P_2 : Window comparator modeHysteresis mode■ P_1=P_2=0 : Out of range mode(The switch output turns on when set pressure is achieved.)输出模式的选择(DEFAULT VALUE: 0%)Reset method Reset content Item Reset content Application model F_1 0%F.S. Current・Voltage input type F_2 100%F.S. Current・Voltage input type P_1、P_2 100%F.S. Switch output type P_1~P_4 0%F.S. Preset input type (Note): Gain (GL) and sensitivity (SL) are not reset.Reset function Reset functionNormal operation does not require the adjustment of gain. This product can change the response with this gain setting.When the gain is changed to more larger, the response become quickly, but there is a possibility that stability is lost. Gain setting Gain settingRelation between setting of gain and response timeNormal operation does not require the adjustment of sensitivity.When the sensitivity is changed, the correction operation of pressure changes. When the sensitivity is changed to sharp, the hunting of pressure might be occurred. And, when the sensitivity is changed to dull, there is a possibility that staggering of gradual pressure occur, because the pressure correction become lower.Sensitivity setting Sensitivity settingThe display can be set to zero again by executing "zero clear".When "zero clear" is executed with residual pressure in the secondary piping, the pressure is assumed to be zero. Please execute the operation of "zero clear" with the supply pressure is intercepted, and the piping of the second side removed. is not executed."Initialize" is a function to return all the settings that the internal control constant are included to an initial value. Please execute "initialize" only when the error is displayed and this product doesn't operate at all. Please execute the "reset" function, when you want to return the pressure setting and the switch setting to an initial value.No Key operation LED Display① Unlock keys (refer to P8)② Press S-key for 2 seconds or more, then go to detail setting mode.Initialize InitializeThe range of the LED pressure display is different according to the pressure range and the unit of the display.unit ITV※01※ ITV※03※ ITV※05※ ITV209※ MPa 。020~.120 。100~.600 。180~.A80 - Kgf/cm 2 0。20~.120 1。00~6.00 1。80~A.80 - bar 0。20~.120 1。00~6.00 1。80~A.80 - PSI 3。0~18.0 14。0~84.0 -26~156 - kPa -20~120 -100~600 -180~A80 16~-96(note1):The mark "。" is blinking the decimal point, and it is shown a minus. (note2):When the digit overflows, the following of "9" are substituted by "A".(example: The following of 999(kPa) are displayed as A00(kPa), and it shows 1000 kPa.)(note3):When the display exceeds the lower bound value, "" is displayed. (note4):When the display exceeds the upper bound value, "" is displayed.This operation manual refers to all standard types and is partially applicable to special models.This operation manual is subject to change without prior notice or any obligation on the part of the manufacturer.LED LED display display。
SMC比例阀ITV使用说明书

ITV1000-※1 ITV2000-※1 ITV3000-※1(模拟输出/电压型)使用说明书值此,谨对您选购SMC 公司的产品表示诚挚的谢意。
请仔细阅读本使用说明书,相信必将有助于您正确使用本产品。
为以防万一,请您一定好好保管此说明书。
安全注意事项这里所描述到的,是提请您正确安全的使用本产品,以防止对您自身和他人造成危害和损害的各种注意事项。
请结合ISO 4414, JIS B 8370以及其他的相关安全规则,务必遵守。
注意关于配管1.请将配管用空气吹净或清洗干净,以除去配管内的切屑,切削油及杂质等。
2.将配管和管接头拧紧时,请注意勿将配管的螺纹切屑及密封材混入配管中。
另需强调,使用密封胶带包卷管接头螺纹时,请在螺纹先端留出1.5~2个螺距的空间。
注意关于压缩气源1. 在靠近本产品的供气侧,请选择安装过滤精度在5μm 以下的空气过滤器。
2. 压缩空气若含有大量的水分,将导致本产品及其他的气动元件作动不良。
请实施相应对策,诸如设置后冷却器,空气干燥器,水分分离器等。
3. 在本产品内部大量附着由空气压缩机所产生的碳粉时,将导致其作动不良。
! !各部分名称外形尺寸配线电缆接线端子安装托架外形尺寸安装孔安装孔UP 键(△键) 设定键(SET 键) DOWN 键(▽键)显示用LEDSUP 接口OUT 接口压力表用接口安装托架(选配)右弯出线型电缆接线端子 (4芯)(选配)安装托架(选配)右弯出线型电缆接线端子直线出线型电缆接线端子 (4芯)(4芯)安装孔安装孔■ 规格供给压力 注1)设定压力+ 0.1MPa,但最大为1MPa0.005~0.1MPa (ITV101※-※1,ITV201※-※1,ITV301※-※1)0.005~0.5MPa (ITV103※-※1,ITV203※-※1,ITV303※-※1) 设定压力0.005~0.9MPa (ITV105※-※1,ITV205※-※1,ITV305※-※1) 约200L/min (ANR) {ITV1000}(供给压力:0.7MPa)约1500L/min (ANR) {ITV2000}(供给压力:0.7MPa) 最大流量约5000L/min (ANR) {ITV3000}(供给压力:0.7MPa)24VDC±10% (ITV10※0-※1,ITV20※0-※1,ITV30※0-※1) 电源电压 注2)12~15VDC (ITV10※1-※1,ITV20※1-※1,ITV30※1-※1) 电源电压 DC24V 型:0.12A 以下消费电流电源电压 DC12~15V 型:0.18A 以下 4~20mADC (ITV10※※-01,ITV20※※-01,ITV30※※-01) 电流型0~20mADC (ITV10※※-11,ITV20※※-11,ITV30※※-11) 0~5VDC (ITV10※※-21,ITV20※※-21,ITV30※※-21) 输入信号 注2)电压型0~10VDC (ITV10※※-31,ITV20※※-31,ITV30※※-31)电流型 250Ω以下输入阻抗电压型约6.5K Ω直线性 ±1.0% F.S.以下 延滞性 0.5% F.S.以下 重复精度 ±0.5% F.S.以下最小压力调整 :调整范围 额定值的0~50%最大压力调整 :调整范围 额定值的10~100%附加机能键锁定机能 :持续摁住UP 键2秒以上,再摁住SET 键,可实现对操作键的锁定。
SMC比例阀参数说明

产品名称:SMC比例阀参数说明
一种是开关控制:要么全开、要么全关,流量要么最大、要么最小,没有中间状态,如普通的电磁直通阀、电磁换向阀、电液换向阀。
另一种是连续控制:阀口可以根据需要打开任意一个开度,由此控制通过流量的大小,这类阀有手动控制的,如节流阀,也有电控的,如比例阀、伺服阀。
所以使用比例阀或伺服阀的目的就是:以电控方式实现对流量的节流控制(当然经过结构上的改动也可实现压力控制等),既然是节流控制,就必然有能量损失,伺服阀和其它阀不同的是,它的能量损失更大一些,因为它需要一定的流量来维持前置级控制油路的工作。
SMCITV系列电气比例阀ITV3050-314CL使用注意事项

SMCITV系列电气比例阀ITV3050-314CL使用注意事项SMC电气比例阀ITV3050系列正品保障;原装正品SMC电气比例阀ITV3050系列到货上海电气比例阀ITV1000·2000·3000系列;SMC电气比例阀ITV3050系列正品保障SMC电气比例阀是一种新型的液压控制装置。
在普通压力阀、流量阀和方向阀上,用比例电磁铁替代原有的控制部分,按输入的电气信号连续地、按比例地对油流的压力、流量或方向进行远距离控制。
一般具有压力补偿性能,输出压力和流量可以不受负载变化的影响。
该比例阀是一种按输入的电信号连续地、按比例地控制液压系统的液流方向、流量和压力的阀类。
普通阀只能通过预调的方式对液流的压力、流量进行定值控制。
但是当设备机构在工作过程中要求对液压系统的压力、流量参数进行调节或连续控制,例如,要求工作台在工作进给时按慢、快、慢连续变化的速度实现进给,或按一定精度模拟某个控制曲线实现旅力控制,普通液压阀则实现不了。
比例阀的输出流量与气体性质,有效通气面积,阀门前后两端的气压压差有关,通过比例阀的气体绝大部分为氧气和空气(N2,O2N_2,O_2N2?,O2?),均为双原子气体分子,气体动力学性质基本相同,在模型中可以不用考虑气体自身性质的影响。
动作原理输入信号增大时,1供气电磁阀变为ON,2排气电磁阀变为OFF。
因此,供给压力通过1供气电磁阀作用在3先导室。
并且,3先导室的压力上升,作用在4膜片上面。
由此结果,与4膜片连动的5供气阀打开,一部分供给压力成为输出压力。
此输出压力,通过7压力传感器反馈到8控制回路。
在此,会进行压力调节,直至输出压力与输入信号成比例,因此,可以稳定地得到与输入信号成比例的输出压力。
高速响应型托架同包出厂。
无负载时的压力响应,响应时间约为0.1sec。
取决于使用环境,非保证值。
输入信号0%时,控制排气电磁阀使输出压力为零。
这种情况下可能会产生噪音,但并非异常。
SMC系列产品使用说明书

5.3对于1-PC和牙嵌式驱动空心轴的电动装置其安装方法是:起吊电动装置使1-PC空心轴孔与阀杆和键配合装入,牙嵌驱式空心轴上的牙嵌与阀门上阀杆螺母的牙嵌对准。用螺栓将电动装置与阀门紧固可靠。
4.1专用电动机:适合阀门的载荷特性和使用工况,型号YLT。
4.2减速机构:用于传递和增大电动机的动力。每个机座产品均有3~5种速比的蜗轮副和若干电机齿轮与蜗杆轴齿轮传动比的齿轮副,因而可获得较大的输出转速范围。
4.3驱动空心轴:它是电动装置的动力输出部件,有2-PC、1-PC、牙嵌式三种型式,结构可见(图10)~(图12)
2.基本技术参数
产品符合JB/T8528-1997《普通型阀门电动装置技术条件》
2.1动力电源:380V、50Hz三相正弦交流电(根据用户要求,某些规格可提供使用单相220V电源的电动机)。
2.2外壳防护等级:SMC-04、03 IP67
SMC-00~5 IP65
2.3使用环境温度:-20℃~40℃;-20℃~60℃(根据用户订货要求)
G·L·SW各列转体上触点的相对位置可任意布置,即同一列上的触点可以全部为“OFF”型式或为“OFF”“ON”两种型式。(最常用的是“OFF”“ON”的布置型式)。
G·L·SW中间的两列转体触点开关可做为阀门某两个中间位置的信号输出,也可将其调整到与两边的转体同步动作。
(图17)为典型控制原理时触点开关的布置型式。
电气接线程序及注意事项:
7.1确认电源电压与电动机使用电压相同。
itv2030-312lsmc比例阀原理smc办事处

itv2030-312l*SMC 比例阀原理*SMC 办事处SMC ITV2000/ITV3000系列电气比例阀控制框图SMC ITV2000/ITV3000系列电气比例阀动作原理图控制框图如上所示。
输入信号增大,供气用电磁先导阀1换向,而排气先导阀7处于复位状态,则供气气压力从SUP 口通过阀1进入先导室5,先导室压力上升,气压力作用在膜片2的上方,则和膜片2相连的供气阀芯4便开启,排气阀芯3关闭,产生输出压力。
此输出压力通过传感器6反馈至控制回路8.在这里,与目标值进行快速比较修正,直到输出压力与输入电信号成一定比例为止,从而得到输出压力与输入电信号的变化成比例变化。
由于没有使用喷嘴挡板机构,故阀对杂志不敏感,可靠性高。
itv2030-312l*SMC 比例阀原理*SMC 办事处3、SMC ITV 系列电气比例阀主要技术参数系列 ITV0000ITV0000 ITV209□型号 ITV001□ ITV003□ ITV005□ ITV009□ ITV201□ ITV301□ ITV203□ ITV303□ ITV205□ ITV305□ITV209□ 设定压力范围/Mpa0.001~0.1 0.001~0.5 0.001~0.9 -1kPa~-100kPa 0.005~0.1 0.005~0.5 0.005~0.9 -1.3kPa~-80kPa 接管口径(Rc 、G 、NPT 、NPTF )快换接头 ITV2000:1/4/·3/8 ITV2000:1/4/·3/8·1/2 1/4 最高供给压力/Mpa 0.2 1.0 -101kPa 0.2 1.0 -101kPa最低供给压力 设定压力+0.1MPa 设定压力-1kPa 设定压力+0.1MPa 设定压力-13.3kPaitv2030-312l*SMC 比例阀原理*SMC 办事处向ITV 比例阀提供清洁干燥的压缩空气,以便能达到ITV 电气比例阀应有的各种特性。
SMC电气比例阀中文手册

S M C电气比例阀中文手册 Prepared on 24 November 2020
SMC电气比例阀中文手册
阀对流量的控制可以分为两种:
一种是开关控制:要么全开、要么全关,流量要么最大、要么最小,没有中间状态,如普通的电磁直通阀、电磁换向阀、电液换向阀。
另一种是连续控制:阀口可以根据需要打开任意一个开度,由此控制通过流量的大小,这类阀有手动控制的,如节流阀,也有电控的,如比例阀、伺服阀。
所以使用比例阀或伺服阀的目的就是:以电控方式实现对流量的节流控制(当然经过结构上的改动也可实现压力控制等),既然是节流控制,就必然有能量损失,伺服阀和其它阀不同的是,它的能量损失更大一些,因为它需要一定的流量来维持前置级控制油路的工作。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
ITV1000-※1 ITV2000-※1 ITV3000-※1(模拟输出/电压型)使用说明书值此,谨对您选购SMC 公司的产品表示诚挚的谢意。
请仔细阅读本使用说明书,相信必将有助于您正确使用本产品。
为以防万一,请您一定好好保管此说明书。
安全注意事项这里所描述到的,是提请您正确安全的使用本产品,以防止对您自身和他人造成危害和损害的各种注意事项。
请结合ISO 4414, JIS B 8370以及其他的相关安全规则,务必遵守。
注意关于配管1.请将配管用空气吹净或清洗干净,以除去配管内的切屑,切削油及杂质等。
2.将配管和管接头拧紧时,请注意勿将配管的螺纹切屑及密封材混入配管中。
另需强调,使用密封胶带包卷管接头螺纹时,请在螺纹先端留出1.5~2个螺距的空间。
注意关于压缩气源1. 在靠近本产品的供气侧,请选择安装过滤精度在5μm 以下的空气过滤器。
2. 压缩空气若含有大量的水分,将导致本产品及其他的气动元件作动不良。
请实施相应对策,诸如设置后冷却器,空气干燥器,水分分离器等。
3. 在本产品内部大量附着由空气压缩机所产生的碳粉时,将导致其作动不良。
! !各部分名称外形尺寸配线电缆接线端子安装托架外形尺寸安装孔安装孔UP 键(△键) 设定键(SET 键) DOWN 键(▽键)显示用LEDSUP 接口OUT 接口压力表用接口安装托架(选配)右弯出线型电缆接线端子 (4芯)(选配)安装托架(选配)右弯出线型电缆接线端子直线出线型电缆接线端子 (4芯)(4芯)安装孔安装孔■ 规格供给压力 注1)设定压力+ 0.1MPa,但最大为1MPa0.005~0.1MPa (ITV101※-※1,ITV201※-※1,ITV301※-※1)0.005~0.5MPa (ITV103※-※1,ITV203※-※1,ITV303※-※1) 设定压力0.005~0.9MPa (ITV105※-※1,ITV205※-※1,ITV305※-※1) 约200L/min (ANR) {ITV1000}(供给压力:0.7MPa)约1500L/min (ANR) {ITV2000}(供给压力:0.7MPa) 最大流量约5000L/min (ANR) {ITV3000}(供给压力:0.7MPa)24VDC±10% (ITV10※0-※1,ITV20※0-※1,ITV30※0-※1) 电源电压 注2)12~15VDC (ITV10※1-※1,ITV20※1-※1,ITV30※1-※1) 电源电压 DC24V 型:0.12A 以下消费电流电源电压 DC12~15V 型:0.18A 以下 4~20mADC (ITV10※※-01,ITV20※※-01,ITV30※※-01) 电流型0~20mADC (ITV10※※-11,ITV20※※-11,ITV30※※-11) 0~5VDC (ITV10※※-21,ITV20※※-21,ITV30※※-21) 输入信号 注2)电压型0~10VDC (ITV10※※-31,ITV20※※-31,ITV30※※-31)电流型 250Ω以下输入阻抗电压型约6.5K Ω直线性 ±1.0% F.S.以下 延滞性 0.5% F.S.以下 重复精度 ±0.5% F.S.以下最小压力调整 :调整范围 额定值的0~50%最大压力调整 :调整范围 额定值的10~100%附加机能键锁定机能 :持续摁住UP 键2秒以上,再摁住SET 键,可实现对操作键的锁定。
表示精度 ±3% F.S.模拟输出 1~5VDC (负载阻抗:1 K Ω以上)监视输出输出精度 ±6% F.S.使用温度 0~50℃(无结露) 温度特性±0.12% F.S. / ℃以下输入信号的保护机能 输入信号超过额定值的150%时,显示LED 上表示为出错(),机能停止。
电流输入型时,输入信号达到40mADC 时护开动以上,保回路始作。
耐电压 外部端子和壳体间加载AC1500V 50/60Hz 1分钟 绝缘阻抗 外部端子和壳体间 100M Ω以上(用DC500V 兆欧表测量)耐振动频率 10~50Hz 振幅 1.5mm 加速度10G X ,Y ,Z 各方向2小时耐冲击 30G ,X ,Y ,Z 三方向各3回 保护构造 本体:IP65相当 电缆接线端子:IP67 质量约250g(无附属品){ITV1000}约350g(无附属品){ITV2000}约620g(无附属品){ITV3000}注1) 输出压力0.1MPa 规格最大供给压力为0.2MPa 。
注2) 超出规格范围时,会发生破损,请注意。
■ 配线方法电缆与本体的端子连接时,请以下记的形式进行配线。
注意因可能发生由于误配线而导致破损的情况,请使用时注意。
请使用容量足够大,脉动小的直流电源。
1 茶 供给电源2 白 输入信号3 青 GND (COMMON)4 黑显示输出注)电缆也有右弯出线型的。
右弯出线型电缆端子向左(SUP 口侧)出线。
端子不能回转,请绝对不要任意旋转端子。
配线图 电流型(ITV ※0※※-01,ITV ※0※※-11)Vs:供给电源 24VDC (ITV ※0※0-※1)12~15VDC (ITV ※0※1-※1)A :输入信号 4~20mADC (ITV ※0※※-01)0~20mADC (ITV ※0※※-11)电压型(ITV ※0※※-21,ITV ※0※※-31)Vs:供给电源 24VDC (ITV ※0※0-※1)12~15VDC (ITV ※0※1-※1)V IN :输入信号 0~5VDC (ITV ※0※※-21)0~10VDC (ITV ※0※※-31)!■ 键锁定机能接入电源后,若本产品处于键锁定状态,则键操作无效。
此时如按键,显示LED 中显示为“”。
〈键锁定状态时按任何键〉〈键锁定状态解除时〉显示用LED显示用LED键锁定的解除方法▽键持续按2秒以上,显示用LED 中“”的字样交替闪灭。
此时按下SET 键,即解除键锁定状态。
(若按△键,即取消上述操作)键锁定的操作方法△键持续按2秒以上,显示用LED 中“”的字样交替闪灭。
此时按下SET 键,就设定了键锁定状态。
(若按▽键,即取消上述操作)①持续按2秒以上②解除键锁定(取消操作)①持续按2秒以上②设定键锁定(取消操作)■ 最小压力/最大压力的调节本产品可针对输入信号进行最小压力及最大压力的调节,能以最小压力0~50%(F.S.),最大压力100~10%(F.S.)的范围进行调节。
■ 显示输出显示用的输出电压依据下表所示。
本产品所连接的计测器件,其所使用的负载阻抗请确保在1k Ω以上。
另外,此输出电压需增幅使用时,请同样考虑设计负载阻抗在1k Ω以上。
型号输出压力(MPa )显示用输出电压(VDC ) 注)ITV ※01※-※1 0.005~0.1 1~5 ITV ※03※-※1 0.005~0.5 1~5 ITV ※05※-※1 0.005~0.9 1~5注)这里所说的“输出电压”,由于内藏的压力传感器的特性以及其所连接的计测器件,电气回路的负载阻抗的变化,多少有些变动,请注意。
最小压力调节范围最大压力调节范围输出压力%输出压力%输入信号输入信号显示输出电压连接方法■ 设定方法 注意设定各参数时,中间出现误操作,或LED 显示异常时,请切断电源,重新启动。
注意最小压力,最大压力的数值设定终了,按下SET 键,调整后的动作立即开始。
请充分注意,小心操作。
注意最小压力的设定,即便没有输入信号,只要一次侧气压有供给,即输出设定了的最小压力。
注意按照操作顺序执行按键操作后,请务必按下SET 键。
◆ 依据键锁定的解除方法,解除键锁定。
请按下SET 键。
◆ 最小压力的设定(显示为“”)用△键,▽键设定希望的最小压力值。
请按下SET 键。
◆ 最大压力的设定(显示为“”)用△键,▽键设定希望的最大压力值。
请按下SET 键。
返回到现在的压力显示,设定终了。
上述的过程中不需要设定的项目,请直接按下SET 键进入下一步操作。
■ 出错信息显示机能针对下述的出错信息,用对应的出错代码在显示LED 中表示。
出错代码“1”出现时,请切断电源,消除了错误内容后,再启动电源。
出现其他的错误代码时,请联系本公司寻求解决。
出错代码出错内容 LED 显示1 输入信号超过额定范围2 EEPROM 的读写操作发生错误3 存储器的读写操作发生错误 4电磁阀的动作异常! ! ! !■ 设定值的复位操作按照键锁定的解除操作方法,键锁定解除操作后,同时摁下△键和▽键达3秒以上,LED 显示就变成“”的交替闪烁的字样。
△键和▽键放开后,就回复到最小压力0% F.S.,最大压力100% F.S.的状态。
■ 使用注意事项注意1. 本产品,在控制状态时,由于停电等异常情况引起电源被切断,能在短时间内保持2次侧的出口压力。
当2次侧为大气开放的状态时,停电后空气还会继续排放,使用时请充分注意。
2. 本产品,在通电状态下停止供给压力时,内藏的电磁阀持续动作,可能会引发噪声。
当停止供气时,请务必同时切断电源。
3. 未使用显示输出时,因可能导致误动作,请注意不要将显示输出端子与其他的电线相接触。
4. 本产品,在出厂前已经对各项规格参数进行了调整。
请顾客一定避免无目的的拆卸,零件的拆装等,以防导致故障。
5. 为避免干扰信号引起的误动作,请执行下述对策。
1)请在交流电源线中加入在线滤波器,除去电源噪声。
2)请尽量将电动机及动力电源线等强电设施,同本产品及与本产品相联的配线相隔离,使本产品不受干扰信号的影响。
3)针对诱导负载(诸如电磁阀,继电器等),请一定实施负载缓冲对策。
6. 由于右弯出线型电缆端子不能回转,请绝对不要任意旋转端子。
①同时摁下达3秒以上!。