gx200固件升级说明书

合集下载

Color Control GX 用户手册说明书

Color Control GX 用户手册说明书

Color Control GX – Firmware change logHow to update?See document ‘Color Control - how to update firmware’ for update instructions. Note that a Color Control which is connected to the internet (with its Ethernet connection), will automatically check for updates every night at 2 AM. It will automatically update itself, provided that automatic updating is not switched off in the setup menu.What firmware version has my Color Control?After power-up, you can find the firmware version in the Setup menu.Change log:v1.11 – 8 jan 2013Recovery image: /feeds/ccgx/images/CCGX-v1_11-RC4-recover.zipChanges:-Fixed ‘Connection to BMV is lost after random time bug’. See v1.09 for details.-VE.Bus BMS and CCGX can now be combined in one system. Important notes on how to install and which sockets to use are in the CCGX Datasheet.-Added support for Lynx Ion to gui and in vrm-logscript-Added support for USB-GPS to gui and in vrm-logscript-Added support for AC Current Sensor to gui and vrm-logscript-Changes to vrm-logscripto BMV Historic data and other similar parameters are logged on change only, to reduce bandwidth usage and database spaceo Backlog information, and flush backlog are added to menu item VRM loggero Added logging of update settings (auto-update, update-to-, local ip-address)o Fixed bug in Solar charger state (ON/OFF) param: it sent 4, it should have been 0.o Energy (kWh) data sent to VRM portal, as used for the consumption and solar yield tab, has been improved in many ways, but can still be further improved.-Improved remote diagnostics. (menu Settings -> General -> Remote Support) See datasheet FAQ for more information-Fixed bug: Temperature alarms on a Multi where interpreted as warnings, and warnings as alarms.-Manual firmware update (with the recovery image) now also works from some USB sticks-Added preliminary version of GPRS modem support. Test available on request.Known issues:-Updating from a previous v1.11-RC requires recovery from a card/stick! Even though it looks like you auto-updated to v1.11-RC4-Finding a USB-GPS might take a while-Remote support on/off setting will be changed from On to Off after a manual firmware update with recovery image.-Support of recovery from USB sticks does not work on all sticks.v1.10 – 8-11-2013Production test changes only, therefore not deployed to automatic update system. Production tests are fixes in the MK2 test script.v1.09 – 6-11-2013Recovery image: /feeds/ccgx/images/CCGX-v1_09-recover.zipChanges:-Fixed ‘losing internet connection’ bug. See v1.08 for details.Known issues:-When connecting multiple BMV’s or VE.Direct MPPT’s, the one used for the overview is chosen randomly.-Bug: Connection to BMV-600 and BMV-700 can be lost after a random time. To get the BMV back online you have to power cycle the BMV (unplug the RJ-12 cable at the back of the BMV, and plug itback in again – Fixed in v1.11.Limitations:-The CCGX connected to VE.Bus cannot be combined with other MK2-based products: VE.Bus BMS, VE.Bus to NMEA2000 interface, BPP2, CCGX, VEConfigure2 and 3, VGR2, VER, Solar-Switch andcustom built applications and software based on the MK2. These combinations can result in suddenpower outages and other unexpected problems.-Do not connect two Color Controls to the same VE.Bus network, see previous limitation.-CCGX cannot be combined with a VE.Bus BMS. Will be fixed in as soon as possible – Solved in v1.11-Data from BMV’s connected with a VE.Direct cable or the VE.Direct USB cable will be logged to the VRM website, but the data is not yet visible on the website. This is being worked on right now and will be fixed in the coming weeks – Fixed with new VRM website, 12 dec 2013.v1.08 – 4-11-2013Changes:-Added support for MPPT 70/15, MPPT 75/15, MPPT 100/15 en MPPT 75/50. Notes:o They can be connected both with a direct VE.Direct cable as well as a VE.Direct to USB interface.o Multiple can be connected at the same time.o The firmware version in the MPPT Solar Charger must be v1.09 or later. MPPT solar charger firmware can be updated with a VE.Direct to USB interface.o The 70/15 needs to be from year/week 1308 or later. Earlier 70/15’s are not compatible with the Color Control GX. MPPT 70/15’s currently shipping from our warehouse are of the requirednewer version.-Added support for connecting multiple BMV’s at the same time-Added time zone setting in menu-Fixed bug: grid converter power for L2, L3 is sometimes not read (and kWh-counted) properly.Sometimes it is.Known issues:-When connecting multiple BMV’s or VE.Direct MPPT’s, the one used for the overview is chosen randomly.-Bug: in some situations, after losing its internet connection, the Color Control requires a restart to have a working internet connection again. (DHCP random address bug). For details see v1.07. Bug is fixed in v1.09-Bug: Connection to BMV-600 and BMV-700 can be lost after a random time. To get the BMV back online you have to power cycle the BMV (unplug the RJ-12 cable at the back of the BMV, and plug itback in again.Limitations:-The CCGX connected to VE.Bus cannot be combined with other MK2-based products: VE.Bus BMS, VE.Bus to NMEA2000 interface, BPP2, CCGX, VEConfigure2 and 3, VGR2, VER, Solar-Switch andcustom built applications and software based on the MK2. These combinations can result in suddenpower outages and other unexpected problems.-Do not connect two Color Controls to the same VE.Bus network, see previous limitation.-CCGX cannot be combined with a VE.Bus BMS. Will be fixed in as soon as possible.-Data from BMV’s connected with a VE.Direct cable or the VE.Direct USB cable will be logged to the VRM website, but the data is not yet visible on the website. This is being worked on right now and will be fixed in the coming weeks.v1.07 – 30-09-2013Recovery image: /feeds/ccgx/images/CCGX-v1_07-recover.zipChanges:-Fixed both known issues from v1.06Limitations:-The CCGX connected to VE.Bus cannot be combined with other MK2-based products: VE.Bus BMS, VE.Bus to NMEA2000 interface, BPP2, CCGX, VEConfigure2 and 3, VGR2, VER, Solar-Switch andcustom built applications and software based on the MK2. These combinations can result in suddenpower outages and other unexpected problems. Note that making a solution for the combination of the CCGX and a VE.Bus BMS is top priority; it is expected in November 2013.-Do not connect two Color Controls to the same VE.Bus network, see previous limitation.-CCGX cannot be combined with a VE.Bus BMS. Will be fixed in as soon as possible.-Only one BMV can be connected. It can be connected with a VE.Direct cable, a VE.Direct USB cable or the VE.Can to NMEA2000 cable together with a BMV-60xS to NMEA2000 interface. Connecting morethan one at the same time will be possible in the near future (November).-Data from BMV’s connected with a VE.Direct cable or the VE.Direct USB cable will be logged to the VRM website, but the data is not yet visible on the website. This is being worked on right now and will be fixed in the coming weeks.Known issues:-Bug: grid converter power for L2, L3 is sometimes not read properly. This also affects the kWh-counters. Occurrence: random. Sometimes it is counted properly. This bug has always been there,since day one. Fixed in v1.08-Bug: in some situations, after losing its internet connection, the Color Control requires a restart to have a working internet connection again. Details:If the Color Control does not receive response on its DHCP request, it will generate a random ip-address. It will not retry getting an ip address through DHCP for at least 3 days, perhaps forever. Atypical situation where this happens is: AC power fails, customers internet router (and DHCP server) is switched off. The Color Control GX is powered from the battery and stays connected. Its Ethernet links goes down. Then the power is restored, router gets power, Ethernet connection comes up again, but the DHCP server is not yet ready. Color Control creates the random address, and will be disconnected from VRM. Workaround: reboot the Color Control GX. This bug has always been there, since day one.Bug will be fixed in v1.09v1.06 – 27-09-2013Changes:-added support for BMV-60xS and BMV-70x connected via the VE.Direct ports. Only one BMV can be connected, more will be possible in the near future.-bug “kwh-counters not logged to vrm after mk2_dbus service restarted” is fixed-production test changes-the current date and time, as shown in the settings menu, is now constantly updated. It used to be updated only once when the user entered this menu.Known issues:-When a BMV is not connected during power up, going to the Overview will cause all values to stop working.-When you are in a second level menu and then go to the overview, the gui does not function proper anymore when a BMV is connected. To go back to normal operation remove BMV or press escape (A, left top) buttonv1.05 – 05-09-2013Production test changes only, therefore not deployed to automatic update systemv1.04 – 05-09-2013Changes:-implemented workaround for missing/losing VE.Bus data bug-removed shutdown functionality and added reboot option in menu settings/general. This is because ofa hardware change (REV1): the Color Control GX will now always be on, it is no longer possible toswitch it off.-added key-press: when keeping a key pressed it will keep scrolling-python sources are now also on CCGX, which makes it easy to change these (open source)Known issues:-Model and version from VE.Can products is not logged to VRM Portal-After updating a Multi the CCGX should be rebooted for correct working of the kWh counters-The battery values are randomly chosen from a BMV or Lynx-Ion when both are available-Missing some translationsLimitations:-Data is logged only with device instance 0v1.03 – 14-08-2013Changes:-Added alarm relay functionality and settings to configure it-Added support for BMV (connected through BMV to NMEA2000 interface) in the main menu-Added support for BlueSolar MPPT 150/70 in the main menu-Added option in menu to choose which types of automatic updates to except (Release / Release Candidate / Testing)-Added check for updates 5 minutes after power up (it used to be only at 02:00 UTC)-Bug fix: total PV watts reported in the overview for paralleled MPPT 150/70 is now correct-Bug fix: total PV watts reported in the overview measured by multiple AC Current Sensors is now correct-Various updates to the translations-Bug fix: format of VE.Bus version number reported to VRM portal is now correctKnown issues:-Model and version from VE.Can products is not logged to VRM Portal-After updating a Multi the CCGX should be rebooted for correct working of the kWh counters-The battery values are randomly chosen from a BMV or Lynx-Ion when both are available-Missing some translationsLimitations:-Data is logged only with device instance 0v1.01 – 19-07-2013Changes:-MAC Address visible when Ethernet is offline-Logger is on by default (only true when newly programmed or recovered)-Added VRM portal ID in VRM online portal menu-Added 'UTC' to current date and time-Added notification when there is an update available online (only visible when automatic updating is switched off)-Added possibility to define AC in 2 (for Quattro) when a custom profile is selectedKnown issues:-Model and version from VE.Can products is not logged to VRM Portal-Model and version of VE.Bus products is not formatted correctly (2612205.0)-After updating a Multi the CCGX should be rebooted for correct working of the kWh counters-The battery values are randomly chosen from a BMV or Lynx-Ion when both are available-Missing some translations-Some texts, for example ‘uur’ which means hour, are shown in Dutch, even when English language is chosenLimitations:-Data is logged only with device instance 0-The CCGX will log data from Lynx Ions, Lynx Shunt VE.Can, BMV and Solar Charger 150/70 to the VRM portal.v1.00 – 17-7-2013First releaseKnown issues:-Model and version not proper logged due to missing on the dbus-After updating a Multi the CCGX should be rebooted for correct working of the kWh counters-The battery values are randomly chosen from a BMV or Lynx-Ion when both are available-Missing some translationsLimitations:-Data is logged only with device instance 0-The CCGX will log data from Lynx Ions, Lynx Shunt VE.Can, BMV and Solar Charger 150/70 to the VRM portal. But it will not show anything about these devices on its own display. Use the System overview page on the VRM Portal to check if these products are connected OK.。

GX操作手册MELSAP--L

GX操作手册MELSAP--L

日文手册原稿:SH-080358-E
本手册不授予任何工业产权或任何其它类型的产权,也不授予任何专利许可。三菱电机对由于使用了本手册中的内容 而引起的涉及工业知识产权的任何问题不承担责任。
© 2008 三菱电机
A-2
A-2
序言
此次,非常感谢贵方购买了三菱综合 FA 软件 MELSOFT 系列。 在使用前请熟读本手册,并在充分理解 MELSOFT 系列的功能及性能的基础上正确地使用。
ॅ䰽 ⊼ᛣ
㸼冫䫭䇃᪡԰ৃ㛑䗴៤♒䲒ᗻৢᵰˈᓩ䍋⅏ѵ៪䞡ӸџᬙDŽ 㸼冫䫭䇃᪡԰ৃ㛑䗴៤ॅ䰽ⱘৢᵰˈᓩ䍋ҎਬЁㄝӸᆇ៪䕏Ӹ䖬ৃ㛑Փ䆒໛ᤳണDŽ
注意根据情况不同,即使 ! 注意这一级别的事项也有可能引发严重后果。 对两级注意事项都须遵照执行,因为它们对于操作人员安全是至关重要的。
妥善保管本手册,放置于操作人员易于取阅的地方,并应将本手册交给最终用户。
GX Developer Version 8
操作手册 (MELSAP-L篇)
MELSOFT
综合FA软件 MELSOFT
SW8D5C-GPPW-C
安全注意事项
(使用之前务必阅读)
在使用本产品之前,应仔细阅读本手册及本手册中所介绍的关联手册,同时在充分注意安全的前提下正确 地操作。 本手册中的注意事项仅记载了与本产品有关的内容。关于可编程控制器系统方面的安全注意事项,请参阅 CPU 模块的用户手册。 在·安全注意事项·中,安全注意事项被分为“危险”和“注意”这二个等级。
目录 安全注意事项 ............................................................................. A - 1 修订记录 ................................................................................. A - 2 序言 ..................................................................................... A - 3 目录 ..................................................................................... A - 3 关于手册 ................................................................................. A - 5 关于本手册中使用的总称与略称 ............................................................. A - 6

HDS_VSP_G200安装配置指南

HDS_VSP_G200安装配置指南

目录第一章产品概述 (2)1.1 产品简介 (2)1.2 型号升级 (2)1.3 主要指标 (2)1.4 高密度扩展柜 (3)1.5 RAID支持 (3)1.6 磁盘相关属性 (3)第二章存储外观说明 (4)2.1 外观说明 (4)2.2 设备安装 (4)2.3 控制器及SVP的IP地址说明 (6)第三章安装和配置SVP (8)3.1 登陆SVP (8)3.2 SVP前置面板说明 (10)3.3 重装管理工具Storage Device (11)3.4 微码更新 (12)第四章SNM2基本操作 (13)4.1 登录管理工具 (13)4.2 安装硬盘 (14)4.3Li ce n se管理 (18)4.4 在线微码升级 (19)4.5 创建热备盘 (20)4.6 删除热备盘 (22)4.7 端口设置 (23)4.8 RAID组划分 (25)4.9 创建LDEVS (26)4.10 Pool配置 (29)4.11 在pool上创建LDEVs (31)4.12 Host Group配置 (33)4.13 添加外部卷 (39)4.14 删除Pool (42)4.15 格式化LEDVS (45)4.16 ADD lUN PATHS 就是映射卷到主机 (47)4.17 删除LEDVs (48)4.18 删除PG(Raid)组 (49)4.19 删除外部卷 (50)4.20 修改网络端口参数 (52)4.21 其他操作 (53)4.22 修改时间 (59)4.23 Warning告警灯消除 (60)第五章MPC 的安装 (62)第六章硬件更换 (68)第七章HUS 110的卷映射给G200 (72)第一章产品概述1.1 产品简介HDS VSPGx00(Panama)系列主要包含以下几个产品:G200、G400、G600、G800,是HDS新一代中高端存储产品。

该系列产品统一运行的存储操作系统为SVOS。

1.2 型号升级存储产品的型号升级,主要是指G400到G600之间的升级,G400可通过购买升级license包及相应的硬件【前后端接口和内存】,可实现无中断应用在线升级到G600,从而提升存储系统的性能。

步科触摸屏固件更新方式

步科触摸屏固件更新方式
步科触摸屏如何固件更新1按住触摸屏后上电出现英文菜单选择第2个选项固件更新
步科触屏如何固件更新
1、 按住触摸屏后, 上电, 出现英文菜单选择第 2 个选项 (固件更新) 。 (如果背后有拨码,将拨码拨到 ON OFF)。 2、打开步科组态软件,将触摸屏和电脑用下载线连接,选择软件 工 具/系统处理。
工具 系统处理
3、点击“系统处理”后,出现下图。
更新内核
更新文件系统
4、选择更新文件系统。
5、选择更新内核。 6、如果是拨码的,请将拨码 拨到 OFF OFF 。 如果这样还不行,则说明这根下载线确实有问题。

Datalink V2 固件升级指南(CAN)说明书

Datalink V2 固件升级指南(CAN)说明书

Datalink Firmware Upgrade Guide(CAN)Tools:Datalink V2 Type-C CableTIPS:1. Please power Datalink by USB port only.2. The ESC requires power supply in the upgrade process. The details will show below.3. It supports upgrading only one ESC at the same time, using the ''-CH1 CL1 +'' port.4. The yellow cable is GND, the middle one cable is CH, and the green cable is CL. No need to connect the positive pole cable. If the colors of your ESC's cables are different with this, please check the cable definition on the user manual.5. Whether the black and white cable is plugged in or not will not affect the upgrade.6. If the LED light flashes red, it is abnormal. Please try to upgrade the firmware of Datalink, or contact our after-sales service.Software:Tips:Select ''CAN->ESC(FAST) '' mode, click OK, and then click ''Communication Settings''.Tips:After scanning, power on your ESC. Then click Stop, the ESC informations will be displayed on the screen. That means the communication succeeded.Tips:Click out the drop-down list at ''Available version'', select the firmware version that you want and click ''Update''Tips:Waiting for the upgrade complete.Tips:After the upgrade is completed, repeat the steps as page 8 to check whether the upgrade is successful or not. If upgrade failed by powering off by accident during upgrading or other cases, please try all upgrade steps again.。

天宝三星固件025升级操作说明

天宝三星固件025升级操作说明

天宝主板三星固件升级操作说明说明:1.适用机型:V30、F61、A8、H32、iRTK。

2.天宝主板三星固件从0.18升级为0.25版本,0.25版本有效期至6月28日。

3.需更新软件:Hi-RTK升级到v3.2.9版本,iRTK主机固件升级到v3.0版本。

目前V30/F61/A8/H32主机固件为v4.8,主机固件无需升级。

一、第一步:使用Y型数据线(GC-3),将主机与电脑相连,开启主机调至外挂移动台模式,打开串口软件sscom32,如图1-1,选择正确的串口。

点击“扩展”,出现图1-2界面。

图1-1图1-2二、第二步:根据主机型号按如下操作。

1.H32\V30\F61\A8:点击图2-1所示黑色框中的数字2,听到主机播报完“升级主板”的语音提示后,关闭sscom32软件。

图2-12.iRTK:按5-6-7顺序,点击图2-2所示黑色框中的数字,每次点击间隔1秒以上,5-6-7三条命令发送完后,关闭sscom32软件。

图2-2三、第三步:如您电脑上的串口为COM1,则直接跳到第四步。

否则按如下操作:右键单击,选“编辑”,出现如下所示:Dcom1为串口号,修改为电脑实际使用的串口,如您电脑上的串口是COM2,则将Dcom1改为Dcom2,然后点“文件->保存”后关闭文档即可。

四、第四步:双击UpdateBD970.bat",出现图4-1所示界面,正在升级固件,等待15分钟左右图4-1界面消失。

图4-1界面消失后,再等待5分钟即可完成固件升级,直接拔电池关机(升级主板固件时不支持电源键关机)。

图4-1五、第五步:验证固件是否升级成功。

开启主机,按键复位下主板,手簿连上主机。

如图5-1,数据板版本显示0.25表明升级成功,显示0.18表明升级失败。

如升级失败重启接收机从第一步开始重新升级。

图5-1。

200smart怎么更新cpu固件

200smart怎么更新cpu固件

CPU 通过RS485 接口从软件操作进行固件更新S7-200 SMART 编程软件,从V2.3 开始具有固件更新的功能。

S7-200 SMART V2.3 CPU 系列包含十二种CPU 型号,分为两条产品线:紧凑型产品线和标准型产品线。

紧凑型CPU 四种: CPU CR20s、CPU CR30s、CPU CR40s 和CPU CR60s ,V2.3 版本不适用于CR40 和CR 60 CPU,即CR40 和CR60 的CPU 固件版本只到V2.2 版本,V2.3 版本CPU 中不包含。

标准型CPU 八种:ST (ST20、ST30、ST40、ST60 ) 和SR ( SR20、SR30、SR40、SR60 ) 紧凑型CPU 无以太网端口,仅CPU 本体集成一个RS485 端口,此端口作为CPU 的唯一编程端口。

使用STEP 7 Micro/WIN SMART 和USB-PPI 电缆可以进行上传和下载程序、监控程序、执行固件更新。

紧凑型CPU 没有microSD 读卡器或任何与使用microSD 卡相关的功能,不支持使用microSD 卡。

因此,如果紧凑型CPU 需要进行固件更新,仅可通过RS485 端口从软件上操作完成。

标准型CPU 各个固件版本均支持使用Micro SD 卡进行固件更新;如果使用软件固件更新,需要保证CPU 固件版本在V2.3 及以上。

V2.3 版本标准型CPU ,可以支持以太网端口使用网线或者RS485口使用USB-PPI 编程电缆进行更新。

使用的CPU类型及固件更新方法对应情况如表1.所示:表1.CPU类型及固件更新方法X:表示支持-- : 表示不支持C : 表示固件版本在V2.3 及以上支持使用编程软件进行固件更新,前提条件:1、编程软件使用V2.3及以上版本。

2、要更新固件的硬件,固件版本为V2.3 或更高版本的模块的固件。

3、如果使用编程电缆需要使用USB-PPI电缆,订货号:6ES7 901-3DB30-0XA0;不支持使用RS232 / RS 485编程电缆更新固件,订货号:6ES7 901-3CB30-0XA0。

理光 GXR 系列相机固件升级说明书

理光 GXR 系列相机固件升级说明书

GXR DIGITAL CAMERA BODYGR LENS A12 50mm F2.5 MACROGR LENS A12 28mm F2.5RICOH LENS S10 24 - 72mm F2.5 - 4.4VC RICOH LENS P10 28 - 300mm F3.5 - 5.6VC GXR MOUNT A12RICOH LENS A16 24 - 85mm F3.5 - 5.5固件升级说明书本说明书说明了从株式会社理光⽹站下载固件以及升级照相机固件的步骤。

GXR和与其相连接的照相机单元的固件均可进⾏升级。

检查固件的当前版本1.1.机⾝。

2.同时按住 [-] 按钮(1)和6(回放)按钮(1秒以上。

•固件版本将会在图像显⽰屏上显⽰⼤约20秒。

3.检查在图像显⽰屏上显⽰的固件版本。

•例如:固件的当前版本为V1.00时,版本将会如下所⽰,显⽰为[MAIN : V 1.00]:2.解压固件1.从株式会社理光⽹站下载固件。

2.双击下载的⽂件或者右键单击⽂件并选择[打开]。

⽂件的扩展名为“.exe”时,对话画⾯出现后点击“确定”。

•将会创建⽂件夹[GXR Update],⽽固件会被解压⾄⽂件夹[Firmware relX.XX(X.XX为版本号)]。

检查⽂件夹[Firmware relX.XX]中是否有以下⽂件。

•请将固件解压后⽣成的⽂件(参见以上⽂件清单)全部复制到SD记忆卡的根⽬录下。

-------- 机⾝ --------MAIN : V 1.00BKUP : V X.XX MONI : V X.XX ADJD : V X.XX EXTD : V X.XX CPU1 : V X.XX ST : XXXXXX CV : XXXXXX-------- 照相机单元 --------MAIN : V 1.00BKUP : V X.XX MONI : V X.XX ADJD : V X.XX EXTD : V X.XX CPU1 : V X.XX SH : XXXXXX CV : XXXXXXilaunch0 ilaunch3 ilaunch4 ilaunch8jlaunch0 jlaunch3 jlaunch4 jlaunch8klaunch0 klaunch3 klaunch4 klaunch8nlaunch0 nlaunch3 nlaunch4 nlaunch8qlaunch0 qlaunch3 qlaunch4 qlaunch8l08firm0 l08firm3 l08firm4 l08firm8l06firm0 l06firm3 l06firm4 l06firm5 l06firm83.将固件复制到SD记忆卡上请准备64MB以上容量的SD记忆卡。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

固件升级说明书
本说明书说明了从株式会社理光网站下载GX200固件以及升级照相机固件的步骤。

执行以下操作,进行固件升级。

1. 检查固件版本
升级前,务必使用以下方法检查固件版本。

如果安装的固件为最新版本,则无需升级。

1.确保照相机的电源已关闭,并将模式转盘切
换至SCENE(场面模式)。

2.同时按住N(超微距)按钮和6(回放)按
钮2-3秒。

•固件版本将会在图像显示屏上显示大约20秒。

3.检查在图像显示屏上显示的固件版本。

•例如:固件版本为V1.00时,版本将会如下所示,
显示为[MAIN : V 1.00]:
MAIN :V 1.00
BKUP :V X.XX
MONI :V X.XX
ADJD :V X.XX
EXTD :V X.XX
CPU1 :V X.XX
SH :XXXXXX
ST :XXXXXX
6(回放)按钮模式转盘
2. 解压固件1.从株式会社理光网站下载固件。

2.双击下载的文件或者右键单击文件并选择[打开]。

•将会出现一个对话框。

3.
单击[确定]。

•将会创建文件夹[GX200 Update],而固件会被解压至文件夹[Firmware relX.XX(X.XX为版本号)]。

检查[claunch3](固件文件)和[claunch8](调整值文件)是否在文件夹[Firmware relX.XX]中。

3. 将固件复制到SD记忆卡上
有两种方法可将固件复制到SD记忆卡上。

•在照相机上插入一张SD 记忆卡,用附带的USB 连接线连接照相机和电脑,然后将固件复制到SD 记忆卡上。

•使用卡片阅读器或卡片写入器将固件复制到SD记忆卡上(需要卡片阅读器或卡片写入器)。

通过USB连接线连接照相机和电脑来复制固件
1.如果您的Windows PC上安装了Caplio 软件,请确认未启动RICOH Gate La。

2.如果正在使用RICOH Gate La,请在工具栏中使用右键单击RICOH Gate La,然后单击[退出]。

•如果工具栏中没有显示RICOH Gate La图标,则无需执行步骤2。

3.为照相机装上一个有足够电量的电池。

4.在照相机上插入SD记忆卡,并开启电源。

5.
在显示的照相机设定菜单上选择[格式化[插卡]],然后按下$按钮。

claunch3claunch8
claunch3claunch8
Windows操作系统
Macintosh操作系统
6.
选择[是],然后按下MENU/OK按钮。


SD记忆卡被格式化。

对记录图像的插卡进行格式化后,所有内容将会消失。

格式化插卡前,将那些您不想删除的图像保存至您的电脑上。

7.
关闭照相机,并用附带的USB连接线连接照相机和电脑。

•照相机将自动开启。

如果照相机没有自动开启,请按下POWER按钮开启电源。

•如果您的Windows PC上安装了Caplio软件,RICOH Gate La可能会自动开启。

若出现这种情况,请退出RICOH Gate La。

•如果Windows XP或Windows Vista中出现了[可移动磁盘]对话框,请单击[取消]。

•如果iPhoto在Mac OS X中开启,请退出iPhoto。

8.
将文件[claunch3]和[claunch8](解压固件时创建)复制到[我的电脑]中的[RICOHDCX]上。

•照相机的驱动器名称可能会因您所使用的操作系统而异。

例如:[可移动磁盘]等。

9.
打开[我的电脑]中的[RICOHDCX],确定固件复制如下。

claunch3claunch8
claunch3
claunch8
RICOHDCX
Windows操作系统
Macintosh操作系统
Windows系统下的显示例
Macintosh系统下的显示例
RICOHDCX
DCIM claunch3claunch8
DCIM
10.Windows系统
固件复制完成后,双击工具栏中的[安全删除硬件]图标。

Macintosh系统
将[RICOHDCX]图标拖放至[废纸篓]图标。

该图标消失后,转至步骤14。

如果跳过步骤10的操作,则固件复制可能会失败。

11.选择[USB Mass Storage Device]并单击[停止]。

12.单击[确定]。

13.单击[关闭]按钮。

14.关闭照相机,并断开USB连接线。

使用卡片阅读器或卡片写入器将固件复制到SD记忆卡上
1.将文件[claunch3]和[claunch8](解压固件时创建)复制到SD记忆卡的根目录上。

2.
将存有固件文件的SD记忆卡插到照相机上。

4. 升级固件1.确保照相机的电源已关闭,并将模式转盘切换至SCENE(场面模式)。

2.同时按住!按钮和6(回放)按钮2-3秒。

•固件升级的确认信息将会显示在图像显示屏上。

3.
按下$按钮选择[是],然后按下MENU/OK 按钮。

•固件升级开始,以下信息将会显示在图像显示屏上。

[正在确认修改文件][正在修改程序]
4.
照相机将会自动关闭电源,并重新启动。

•如果显示[修改文件不正确]信息,同时照相机自动关闭,请再次检查照相机模式并使用正确的固件重新升级。

•格式化SD记忆卡时,复制到SD记忆卡上的固件文件将被删除。

若有必要,请删除该文件。

6(回放)按钮
! 按钮
模式转盘。

相关文档
最新文档