第42卷 第10期 2009年10月 天 津 大 学 学 报 Journal of Tianjin UniversityV ol.42 No.10Oct. 2009收稿日期:2008-09-23;修回日期:2009-03-10.作者简介:马瑞娜(1977— ),女,硕士,讲师. 通讯作者:赵树鹏,zhaoshupeng100@.热镀锌助镀剂中亚铁离子在线检测技术马瑞娜,赵树鹏,曹晓明,温 鸣,李贺坤,杜 安(河北工业大学材料科学与工程学院,天津 300130)摘 要:针对热镀锌助镀剂中亚铁离子对热镀锌产品质量的影响及其对在线检测的必要性,分析了热镀锌助镀剂溶液的光谱吸收,并在分光光度分析的基础上,根据其光谱特点自行研制了一种亚铁离子自动检测仪,通过微型蠕动泵和该检测仪实现了热镀锌助镀剂中亚铁离子的在线检测.该过程不需要对助镀剂进行其他预处理,操作简便、快速.结果表明,亚铁离子浓度在0.1~10 g/L 范围内,检测误差小于0.05 g/L ,吸光度浓度线性方程相关系数R =0.999 95. 关键词:助镀剂;亚铁离子;在线检测;自动化控制;分光光度分析中图分类号:TP274 文献标志码:A 文章编号:0493-2137(2009)10-0877-07Online Measuring Technology of Ferrous Ion in Flux ofthe Hot -Dip GalvanizingMA Rui-na ,ZHAO Shu-peng ,CAO Xiao-ming ,WEN Ming ,LI He-kun ,DU An(School of Materials Science and Engineering ,Hebei University of Technology ,Tianjin 300130,China )Abstract :Because of the significant effect of ferrous ion in flux on the quality of hot-dip galvanizing products and the nec-essary of the online detection of ferrous ion ,the spectral absorption of the ferrous ion in flux has been investigated in this paper. Based on spectrophotometric analysis ,the automatic detection equipment for ferrous ion has been developed according to its special characteristics. Online measuring of ferrous ion in flux of the hot-dip galvanizing has been achieved with micro-pump and the equipment ,which is simple ,rapid and does not need pretreatment of the flux. Experimental results show that the measuring error is less than 0.05 g/L and the linear equation of the absorption and concentration of the ferrous ion shows a good related coefficient of 0.999 95(R = 0.999 95) when the ferrous ion concentration is between 0.1 g/L and 10 g/L in the flux.Keywords :flux ;ferrous ion ;online measuring ;automated control ;spectrophotometric analysis使用溶剂法生产热浸镀Zn-Al 合金是一种既经济又简便的方法,助镀剂在热浸镀工艺中起着举足轻重的作用.助镀剂中的亚铁离子对镀锌工艺有消极影响[1-3],当助镀剂中Fe 2+含量太高,会使锌锅中的锌渣量增加,影响镀层质量,严重时使镀锌用助镀剂完全失效[4-5].研究表明,只有当亚铁离子的含量稳定地维持在2.0 g/L 以下时,才能保证不会出现漏镀、疤刺等镀锌缺陷.为了保证连续稳定地将助镀剂中亚铁离子含量保持在较低的水平,从而实现最大限度的节锌和改善工件的镀锌质量,需要及时清除助镀剂中的亚铁离子.目前的方法是将助镀剂的温度加热到85℃以上,加入H 2O 2氧化剂和NH 4Cl ,使亚铁盐转变为铁盐沉淀,若亚铁盐含量太高,就只有排放重配.然而如何保证亚铁离子含量保持在较低水平,需要人工不定时地对助镀剂取样进行铁离子检测,此方法不能保证连续生产和热浸镀高质量的要求.对溶液中铁离子浓度的检测方法比较多,如化学滴定法[6]、分光光度法[7-,8]、原子吸收光谱法[9]和目前较为先进的单色冷光源技术、原子(离子)吸收和原子发射光谱等技术.该类方法检测精度高,但是前处理繁琐,成本高,只能够取样测定浓度不能实现在线检测.并且目前关于铁离子在线检测的相关报道甚少.在线检测的目的是使助镀剂中亚铁离子浓度控制在某一个最佳值(即使助镀剂的触媒作用达到最·878· 天 津 大 学 学 报 第42卷 第10期佳),为连续清除助镀剂中铁离子提供依据,保证热镀锌产品快速高质量的生产,满足现代社会市场经济下高效率、高质量和低成本的要求.因此,笔者对热镀锌工艺中助镀剂中铁离子浓度在线检测进行了研究.1 分光光度分析原理分光光度法是以朗伯-比尔定律[10](亦称光的吸收定律)为基础的,即溶液的吸光度与溶液中有色物质的浓度及液层厚度的乘积成正比例,其数字关系式为A=KbC (1) 当b 和K 一定时,式(1)可写为A =mC (2) 式中m 为常数,根据吸收定律,用标准曲线法建立线性关系.在相同的吸收池和同一波长的单色光条件下,以去离子水为参比,配制一系列标准溶液,分别测定各种标准溶液的吸光度.以吸光度为纵坐标,以组成浓度为横坐标做图,即得一条通过原点的直线,称为标准曲线简图,如图1所示.图1 标准曲线简图Fig.1 Standard curve diagram2 热镀锌助镀剂溶液中各离子的光谱吸收特征热镀锌助镀剂是氯化锌、氯化铵的混合溶液,助镀剂中通常含有H +、NH 4+、Cl -、Zn +、Fe 2+和Fe 3+,为了分析各种离子的吸光光谱,分别对以下溶液进行光谱研究(200~1000nm 波长范围内).①pH <2的HCl 溶液;②pH >5的NHCl 3溶液;③pH <2,2+[Fe ]ρ= 4g/L 的FeCl 2溶液;④pH <2,3+[Fe ]ρ=1g/L 的FeCl 3溶液;⑤pH <2,2+[Zn ]ρ=200g/L 的ZnCl 2溶液;⑥pH <2,2+[Zn ]ρ=200g/L ,2+[Fe ]ρ=4g/L 的助镀剂溶液;⑦pH <2,2+[Zn ]ρ=200g/L ,2+[Fe ]ρ=4g/L ,3+[Fe ]ρ=0.1g/L 的助镀剂溶液.光谱图如图2~图5所示,其中图2~图4的扫描步长为1nm ,图5的扫描步长为0.5nm.图2 助镀剂中各种离子的光谱吸收图Fig.2 Spectrograms of a variety of ions in flux图3 pH <2,ρ3+[Fe ]=1 g/L 的FeCl 3溶液光谱图 Fig.3 Spectrogram of FeCl 3 solution (pH <2, ρ3+[Fe ]=1 g/L )图4 pH <2,ρ2+[Zn ] =200 g/L ,ρ2+[Fe ]=4 g/L ,ρ3+[Fe ]= 0.1g/L 的助镀剂溶液光谱图Fig.4 Spectrogram of flux solution (pH <2,ρ2+[Zn ]=200 g /L , ρ2+[Fe ]=4 g/L ,ρ3+[Fe ] =0.1 g/L )图5 pH <2的助镀剂、FeCl 2溶液和FeCl 3溶液的光谱吸收图Fig.5 Spectrograms of flux with pH <2,FeCl 2 and FeCl 3solutions2009年10月马瑞娜等:热镀锌助镀剂中亚铁离子在线检测技术 ·879·分析图2~图5可知,助镀剂中的H+、NH4+、Cl-、Zn2+和Fe3+等离子在波长400 nm以上都没有吸收峰;Fe2+在300~400 nm和700 nm以上的两个光谱范围都有吸收峰,但在300~400 nm内Zn2+、Fe3+对其有影响.故此,实验选用发光波长在700nm以上的特制发光二极管为光源.3 在线检测系统设计3.1 总体在线系统结构简图根据热镀锌工艺酸性锌盐助镀剂的实际性质和对助镀剂中Fe2+在线影响因素分析,设计了在线检测循环系统.在线检测系统结构如图6所示. 本系统采用单色冷光为光源,红外光电传感器为光敏接收器.助镀剂经过机械过滤后,对滤液进行分光光度分析.通过光电检测信号处理、单片机处理及显示,计算可知助镀剂中的亚铁离子含量.图6在线检测系统结构Fig.6Framework of online measuring system在线检测结构由一个循环回路、一个数据采集通道和信息反馈构成.由①②③④①构成助镀剂循环回路;由⑤④⑥⑦构成数据采集通道;由⑦⑧构成信息反馈.其中机械过滤除去杂质;微型蠕动泵给整个检测系统助镀剂流动提供动力;单片机完成数据采集与亚铁离子浓度计算并通过数码管显示浓度等功能.3.2 主要硬件设计原理本系统在分光光度法的基础上,通过光电效应将透过被检测助镀液光强度变化转化为光电流信号变化,再将光电流信号经过I/V转换电路转化为能够被A/D转换采集到的模拟电压信号,A/D转换器将采集的模拟电压信号转换成单片机能够识别的数字电压信号,最后由单片机进行数据处理、浓度的计算及显示等任务.整体设计在低成本、小体积及可靠性高的原则下选择以下主要硬件.(1)选用单色性好,价格低,功耗低、发光效率高、冷光源发光二极管为光源[11].(2)选用光敏范围在400~1300nm,暗电流小、线性度好的红外光电传感器为光敏接收器.(3)由于整个I/V转换电路的失调电压及漂移与第一级有密切关系,因此选用具有超低失调电压和超低漂移的仪器放大器[12]ICL7650集成运放,而且第一级承担仪器放大器的全部放大作用,必须保证I/V转换的线性放大.因为第二级的漂移和失调电压对整个电路的作用大大降低,但其共模抑制比CMRR对整个电路的CMRR影响很大,因此第二级选用价格更为低廉、性能也较优越的低漂移集成运放OP07.本电路因第一级增益较大,易引起自激振荡,因此在2个R f电阻两端加上150pF的电容.微电流放大器原理如图7所示,由ICL7650前置放大器和OP07电压放大器两部分组成I/V转换电路.R12与C19用来滤去ICL7650的斩波尖峰噪声,C16与R f组成反馈补偿网络,降低带宽,防止R f以及C19相移产图7微电流放大器原理Fig.7Microcurrent amplifier schematic diagram·880·天津大学学报第42卷 第10期生自激振,电阻R f为了保证I/V转换的线性度,以提高增益的稳定性和精度,减小噪声,此时第一级输出电压U0=-I S R f,第二级放大电压U1=-(R14/R13)·U0=(R14×R f/R13)I S=8×106I S,保证了放大满足y=K0x的线性度;当光电流最小为I S=10-9A时,最小放大电压U1=8mV.采用单片机控制,实现自动校零以及过流保护.(4)A/D转换器选用满足检测要求的ADC0804,它是常用的8位COMS逐次逼近寄存器、三态锁定输出、20脚双列直插、典型转换时间为100µs的A/D 转换器.(5)控制中心单片机[13]选用ATMEL公司的低价格、高性能、内置看门狗的AT89S52单片机.3.3 控制系统原理控制系统原理如图8所示.系统的控制部分主要有工控微型动力泵和数据采集卡的控制端.通过多通道电源、接线端子卡、继电器和恒流源驱动器(V/I驱动器)构成中间环节驱动器.A/D转换器采集传感器的数据送至AT89S52单片机和设置值比较运算,再通过数码管显示浓度,控制报警器同时给在线除铁设备提供反馈信息,并通过驱动器和继电器实现对数据的采集和工控微型泵的控制.图8控制系统原理Fig.8 Diagram of control system principle3.4 软件编程设计主程序是亚铁离子浓度检测仪的重要程序,是一个顺序执行的无限循环的程序.它负责调度系统的各应用程序模块,并与系统的外部设备及时交换信息,实现系统软、硬件资源的整体管理.系统的主程序第一次运行时,首先初始化各个子程序和各种电平触发开关,本系统采用高电平触发开关.启动V/I驱动器,启动数据存储器件调用参比值,同时启动A/D 转换器采集入射光强I0和透射光强I并计算吸光度A.使用最小二乘法计算求得溶液的浓度ρ,然后保存并显示测量结果.当检测浓度大于检测要求的上限时,单片机发出报警和反馈信息启动除铁设备.系统的主程序流程如图9所示[13].图9软件控制流程程序Fig.9Flow chart of software control4 实验结果及分析4.1 在线检测的主要影响因素助镀剂中亚铁离子的在线检测有很多影响因素,如助镀剂中的杂质、光源的单色性、最大吸收峰和亚铁离子的氧化性等.根据铁离子性质,温度越高,亚铁离子氧化越快,检测误差越大;另一方面亚铁离子吸收能量后形成热运动,其化学表达式为2+3+22Fe(H O)Fe(H O)⎯⎯⎯→能量(3)由式(3)可知:温度越高,分子运动越剧烈,进而影响透过光的稳定性,引起检测误差.分光光度分析要求光源在检测时保持光强度一定,因为对于同一浓度的亚铁离子来说,使用不同的光强度照射,它的透射率是不同的.这些因素严重影响检测的准确度.因此,温度高低和光源强度的大小是最主要的影响因素.图10~图13分别为温度、光强度、光距和杂质对吸光度的影响.由图10可知:pH<2,2+[Fe]ρ=2g/L的助镀剂溶液随着温度的上升吸光度值依次增大,根据标准方程计图10温度对吸光度的影响Fig.10Influence of temperature on abstraction2009年10月马瑞娜等:热镀锌助镀剂中亚铁离子在线检测技术 ·881·图11光强度相同时不同光距对吸光度的影响Fig.11Influence of different light distances on abstraction with the same light intensity图12光距相同时不同光强度对吸光度的影响Fig.12Influence of different light intensities onabstraction with the same light distance助镀剂图13杂质对吸光度的影响Fig.13Influence of impurity on abstraction算可知浓度误差也在依次增大.为了减小检测误差,被检测液(工厂助镀液实际温度一般在75~95℃)的温度应尽量保持室温,从图中可以看出,40℃到室温的温度范围内检测到的Fe2+含量与实际含量完全相同,因此,在线检测时,助镀液要进行冷却处理,使助镀液在被检测前冷却到40℃以下.但是实际在线检测时,助镀液经过工控泵长距离传输温度一般下降到室温左右.图11为在光强度不变的条件下,光距为80mm 和45mm时同一浓度不同的吸光度值;图12在光距不变的条件下,光强度为14.28mW和8.78mW时同一浓度不同的吸光度值.由图11和图12可知:吸收池一定的情况下,光强度相同,光距越大吸光度越小,检测误差越大;光距相同,光强度越小吸光度越小,检测误差越大.主要原因是当光距太大或光强度太小时,透过吸收池的光强度变化减小,从而影响检测的准确度.因此,在吸收池和光距一定的情况下,尽可能提高光源的发光强度.图13为同一样品经过过滤与未过滤的吸光度值.由图13可知:在5种不同浓度的工厂助镀剂过滤和未过滤的情况下,检测的吸光度值不同,未过滤的吸光度值明显大于过滤后的吸光值.其中,6#、5#、4#、2#和1#依次使用100目、20目、60目、50目和40目过滤网过滤后的检测吸光度值,可见选用100目过滤网基本上满足仪器检测准确度的要求.实际工况情况下,为了保证过滤网口不被堵塞又能够满足检测液流速的要求,采用自动过滤器.实验证明,当pH=2.5~5.5时,助镀剂溶液中会出现少许的氢氧化锌沉淀颗粒,形成杂质从而影响检测结果,因此,只有保持pH<2时,才能够保证检测结果的准确.4.2 建立在线检测吸光度与浓度线性方程在吸收池和光距一定的条件下,以去离子水为参比,光强度为8.78mW和14.28mW时检测2+[Fe]ρ分别为1g/L、2g/L、3g/L、4g/L、5g/L、6g/L和7g/L的一系列助镀剂的吸光度值,从而建立浓度与吸光度的线性关系,如图14和图15所示.利用最小二乘法建立回归方程.图14光强度8.78 mW的标准吸光度与浓度曲线Fig.14Standrad linear equation diagram for lightintensity 8.78 mW图15光强度14.28 mW的标准吸光度与浓度曲线Fig.15Standrad linear equation diagram for lightintensity 14.28 mW·882·天津大学学报第42卷 第10期光强度为8.78mW时回归方程为A x=0.02027ρx+0.00395 (4)其相关系数R=0.99992,标准误差为0.000 758.光强度为14.28mW时回归方程为A x=0.02022ρx+0.00223 (5)其相关系数R=0.99995,标准误差为0.000577.4.3 检测结果及滴定法测定结果对比工厂实际用重铬酸钾滴定法检测助镀剂中的亚铁离子浓度,其原理是用重铬酸钾氧化亚铁离子为三价铁离子,当亚铁离子完全氧化后多余的重铬酸钾与酚酞反应显示紫红色,这时记录所用重铬酸钾的体积,经计算得到亚铁离子浓度.从工厂不同工作时段分别取得的6种助镀剂用以上两种方法的检测结果对比如表1和表2所示.表1回归方程式(4)与滴定法检测结果对比Tab.1Comparison of measuring results between the stan- dard linear equation(4)and titrationρ/(g·L-1)助镀剂滴定法光电法1# 2.23 2.342#9.449.423#7.107.574# 6.987.115# 6.70 6.726#8.329.04表2回归方程式(5)与滴定法检测结果对比Tab.2Comparison of measuring results between the stan- dard linear equation(5)and titrationρ/(g·L-1)助镀剂滴定法光电法1# 2.23 2.322#9.449.413#7.107.434# 6.987.085# 6.70 6.826#8.328.33由表1和表2可知:在吸收池、光距一定的情况下,光强度越大标准曲线的相关系数越接近1,检测结果的误差越小,即检测准确度越高.4.4 检测准确度验证实验结果在室温25~30℃之间,对2+[Fe]ρ分别为0.01g/L、0.03g/L、0.05g/L、0.10g/L、0.30g/L、0.50g/L、0.70g/L和1.00g/L的一系列助镀剂溶液,依次检测吸光度值,分别用回归方程式(4)和式(5)计算浓度,数据如表3所示.表3标准助镀液与回归方程检测误差对比Tab.3Comparison of measuring errors between the stan- dard linear equation and standard flux solutionρx/(g·L-1)2[Fe]ρ+/(g·L-1)式(4)计算式(5)计算0.01-0.070 0.0130.03-0.040 0.0460.05-0.009 5 0.0780.10 0.025 0.1100.30 0.025 0.3400.50 0.430 0.5200.70 0.630 0.7201.00 0.920 1.006在本实验原理和在线检测特定条件基础上,通过自制亚铁离子检测仪,依次检测含有亚铁离子浓度为0.01~1.00g/L的标准助镀液样品.检测结果数据统计于表3中,分析可知,式(4)计算浓度与标准浓度误差比较大;式(5)计算浓度在2+[Fe]ρ<0.10g/L时,相对于标准浓度误差差异比较大;在2+[Fe]ρ≥0.10g/L时,相对于标准浓度检测误差小于0.05g/L.实验进一步证实,利用式(5)回归方程检测亚铁离子浓度在0.1~10g/L范围内,检测误差均小于0.05g/L.5 结 语在分光光度法的基础上,结合光电原理和单片机控制原理,自行研制了亚铁离子检测装置.实验证实该检测装置利用式(5)回归方程检测亚铁离子浓度在0.1~10g/L范围内,检测误差均小于0.05g/L,满足工业检测浓度的要求,实现了热镀锌助镀剂中亚铁离子的在线检测,替代传统的人工取样滴定测定.能够对现有热镀锌工艺中在线助镀剂除铁设备及时提供反馈信息,以保证助镀槽内助镀剂中Fe2+浓度小于某一特定值,使助镀剂能够达到最好的助镀效果.为热镀锌自动化生产线分析产品质量及降低生产成本提供了重要的依据.本检测系统对经过过滤器的助镀剂不需要其他预处理直接进行检测,由于微型泵对助镀剂的传输使检测能够达到实时快速检测.在今后的研究中可以通过进一步改进光路设计提高光强度;还可以改善对光电信号以及干扰信号的处理,使得该检测装置达到更高的精度及可靠性,实现助镀剂中亚铁离子长期稳定的在线检测.在线检测仪器应向智能化、简单化的方向进一步完善和发展.2009年10月马瑞娜等:热镀锌助镀剂中亚铁离子在线检测技术 ·883·参考文献:[1]袁志敏,张素荣. 热镀锌用助镀剂探讨[J]. 腐蚀与防护,2002,23(5):225-226.Yuan Zhimin,Zhang S urong. Flux in hot-dip galvaniz-ing[J]. Corrosion and Protection,2002, 23(5):225-226(in Chinese).[2]Townsend H E,Allegra L,Dutton R J,et al. Hot-dip coated sheet steel:Review[J]. Mat erials Performance,1986,25(8):36-46.[3]Moller G A. New Technology of Melting Flux Method of Hot-Dip Aluminizing Process:US 2315725[P].1948. [4]杨 冰,申晓刚,马 林,等. 连续清除热镀锌助镀剂中铁离子的工艺技术[J]. 电镀与涂饰,2005,24(8):14-17.Yang Bing,Shen Xiaogang, Ma Lin,et al. Technique ofcontinuous removing ferric ion in plating auxiliary withhot-dip galvanizing[J]. Elec t ropla t ing & Finishing,2005, 24(8):14-17 (in Chinese).[5]Fratesi R,Ruffini N,Malavolta M,et al. Contemporary use of Ni and Bi in hot dip galvanizing[J]. Surface andCoatings Technology,2002, 157(3):34-39.[6]Tzur D,Dosortzev V,Kiroma-Eisner E. Titration of low levels of Fe2+ with electrogenerated Ce4+[J]. AnalyticaChimica Acta,1999,392(2/3):307-318.[7]Nascimento P C,Jost C L,Guterres M V. S imultaneous determination of Al(Ⅲ)and Fe(Ⅲ)in post-hemodialysisfluids by spectrophotometry and multivariate calibra-tion[J]. Talanta,2006,70(3):540-554.[8]Zareba S tanislaw,S zarwilo Katarzyna,PomykalskiArkadiusz. Determination of Fe(Ⅱ) and Zn(Ⅱ) byspectrophotometry,atomic absorption spectrometry andions chromatography methods in Vitrum[J].ⅡFarmaco,2005,60(5):459-464.[9]S abermahani Fatemeh,Mohammad Ali Taher. Applica-tion of a new water-soluble polyethylenimine polymersorbent for simultaneous separation and preconcentrationof trace amounts of copper and manganese and their de-termination by atomic absorption spectrophotometry [J].Analytica Chimica Acta,2006,565(2):152-156. [10]陈国珍,黄贤智. 紫外:可见光分光光度法[M]. 北京:原子能出版社,1987.Chen Guozhen,Huang Xianzhi. Ultraviolet:Visible Spec-trophotometry[M]. Beijing:Atomic Energy Press,1987(in Chinese).[11]Fonseca A,Raimundo I M Jr. A simple method for wa-ter discrimination based on light emitting diode (LED)photometer[J]. Analyt ica Chimica Act a,2007,596(1):66-72.[12]陈国杰,曹 辉. 高性能微电流集成放大器的设计[J].核电子学与探测技术,2005,25(3):243-245.Chen Guojie,Cao Hui. The design of high performanceweak current integrated amplifier[J]. Nuclear Elect ron-ics and Det ect ion Technology,2005,25(3):243-245(inChinese).[13]刘文涛. 单片机应用开发实例[M]. 北京:清华大学出版社,2005.Liu Wentao. Examples of Single-Chip Application Devel-opment[M]. Beijing:Tsinghua University Press,2005 (inChinese).热镀锌助镀剂中亚铁离子在线检测技术刊名:天津大学学报英文刊名:JOURNAL OF TIANJIN UNIVERSITY年,卷(期):2009,42(10)1.Sabermahani Fatemeh;Mohammad Ali Taher Application of a new water-soluble polyethylenimine polymer sorbent for simultaneous separation and preconcentration of trace amounts of copper and manganese and their determination by atomic absorption spectrophotometry[外文期刊] 2006(02)2.袁志敏;张素荣热镀锌用助镀剂探讨[期刊论文]-腐蚀与防护 2002(05)3.Zareba Stanislaw;Szarwilo Katarzyna;Pomykaiski Arkadiusz Determination of Fe (Ⅱ) and Zn (Ⅱ) byspectrophotometry,atomic absorption spectrometry and ionschromatographymethodsinVitrum[外文期刊] 2005(05)4.Nascimento P C;Jost C L;Guterres M V Simultaneous determination of Al (Ⅲ) and Fe (Ⅲ) in post-hemodialysis fluids by spectrophotometry and multivariate calibration[外文期刊] 2006(03)5.Tzur D;Dosortzev V;Kiroma-Eisner E Titration of low levels of Fe~(2+) with electrogenerated Ce~(4+)[外文期刊]1999(2/3)6.Fratesi R;Ruffini N;Malavolta M Contemporary use of Ni and Bi in hot dip galvanizing[外文期刊] 2002(03)7.杨冰;申晓刚;马林连续清除热镀锌助镀剂中铁离子的工艺技术[期刊论文]-电镀与涂饰 2005(08)8.Moller G A New Technology of Melting Flux Method of Hot-Dip Aluminizing Process 19489.Townsend H E;Allegra L;Dutton R J Hot-dip coated sheet steel:Review 1986(08)10.刘文涛单片机应用开发实例 200511.陈国杰;曹辉高性能微电流集成放大器的设计[期刊论文]-核电子学与探测技术 2005(03)12.Fonseea A;Raimundo I M Jr A simple method for water discrimination based on light emitting diode (LED) photometer[外文期刊] 2007(01)13.陈国珍;黄贤智紫外:可见光分光光度法 19871.熊中恒.吕基星.XIONG Zhongheng.L(U) Jixing枕头坝水电站砂石料加工系统自动化控制[期刊论文]-水利水电技术2011,42(5)2.韩永良.HAN Yong-liang聚酯装置自动化控制系统分析及探讨[期刊论文]-合成纤维2009,38(7)3.於建明.沈国江.沙昊雷.YU Jian-ming.SHEN Guo-jiang.SHA Hao-lei生物滴滤床净化含H2S废气自动化控制[期刊论文]-解放军理工大学学报(自然科学版)2008,9(3)4.孙辰昀.SUEN Chenyun污水处理厂提升泵站自动化控制的改进[期刊论文]-新技术新工艺2011(12)5.张永金.白永环.祝长青.王淑华.宋志伟.张志昊.ZHANG Yong-jin.BAI Yong-huan.ZHU Chang-qing.WANG Shu-hua.SONG Zhi-wei. ZHANG Zhi-hao热镀锌助镀液在线循环使用的研究与应用[期刊论文]-电镀与精饰2009,31(4)本文链接:/Periodical_tianjdxxb200910006.aspx。
热镀锌氯化亚铁含量指标

热镀锌氯化亚铁含量指标
(实用版)
目录
1.热镀锌概述
2.氯化亚铁在热镀锌中的作用
3.氯化亚铁含量的检测方法
4.氯化亚铁含量对热镀锌的影响
5.结论
正文
一、热镀锌概述
热镀锌是一种在金属制品表面涂覆锌层的工艺,可以提高金属制品的耐腐蚀性、延长使用寿命。
在热镀锌过程中,助镀液的成分对于镀层的质量至关重要。
二、氯化亚铁在热镀锌中的作用
氯化亚铁在热镀锌中作为助镀剂,可以促进锌层的形成,提高镀层的质量。
在热镀锌过程中,氯化亚铁可以与锌离子发生反应,形成锌亚铁氯化物,进而在金属表面生成锌层。
三、氯化亚铁含量的检测方法
氯化亚铁含量的检测通常使用 pH 计进行。
pH 计可以直接测量溶液
的酸度,从而间接反映出氯化亚铁的浓度。
此外,还可以通过测量溶液中的氯离子含量来间接检测氯化亚铁的含量。
四、氯化亚铁含量对热镀锌的影响
氯化亚铁含量对于热镀锌过程有着重要影响。
如果氯化亚铁含量过高,会导致镀层质量下降,出现镀层不均匀、针孔等问题。
相反,如果氯化亚
铁含量过低,镀层的质量也会受到影响,出现附着力差、镀层薄等问题。
因此,在热镀锌过程中,需要控制好氯化亚铁的含量。
五、结论
氯化亚铁在热镀锌中起着重要作用,对于镀层质量有着重要影响。
因此,在热镀锌过程中,需要对氯化亚铁含量进行严格的控制,以保证镀层的质量。
热镀锌工艺中亚铁离子的连续清除

热镀锌工艺中亚铁离子的连续清除和对工艺过程最优化的要求Andrew Herd 冰(市工大镀锌设备)摘要这是一种新型的工艺技术,在商业生产中用于稳定连续的清除助镀剂溶液中的亚铁离子,先将亚铁离子氧化成3价铁离子,然后将其变为零电荷的沉淀除去,此化学过程通过一个先进的、能运输大量粒子的双室电解槽来完成。
应用此项工艺,要达到稳定连续除铁的效果,需要对热镀锌前处理工序的一些参数加以控制,对这些参数的要求详细的列于下文。
此外,导致最终镀层比实际所需镀层要厚的原因,本文也将略一阐述。
关键词电解的,亚铁离子,脱脂, 酸洗,清洗,助镀剂,热镀锌,锌渣,EPIORContinuous Removal Of Ferrous Iron From The Pre-Flux In The Hot Dip Galvanising Process; The Process And Requirement for Process OptimisationAndrew Herd Yang Bing(Tianjin Gongda Galvanizing Equipment Co., Ltd.)Abstract A novel, commercially used, process for the continuous removal of ferrous iron from pre-flux by oxidation of the ferrous form to the ferric and its removal as a zero charged precipitate by use of an advanced, divided, high mass transport electrolytic cell is described. Process control requirements required for the preparation processes in general hot dip galvanising to achieve consistent results using this iron removal process are set out in detail. Mechanisms causing the formation of thicker than sought coatings are proposed.Key Words Electrolytic; Ferrous iron; Degreasing; Pickling, Rinse; Pre-flux; Hot dip galvanising; Dross; EPIOR1.简介本文的主旨在于介绍一种新工艺,该工艺将亚铁离子连续稳定地从助镀剂中清除。
PAM对热镀锌助镀液中铁离子去除效果研究

PAM对热镀锌助镀液中铁离子去除效果研究于梦琦;党康飞;李顺义【摘要】热镀锌助镀液中铁离子含量过高会严重影响镀层质量.本文采用化学沉淀法处理热镀锌助镀液原水中过量的铁离子.采用双氧水氧化法氧化水样中的Fe2+离子,调节pH到4.5 ~5.0,使铁离子生成Fe(OH)3沉淀,分别加入不同类型的聚丙烯酰胺(PAM)絮凝.结果表明:投加过氧化氢15 mL/L时对水样中的Fe2+离子氧化效果最好,离子度为40的阳离子型PAM在浓度为0.06 g/L时对氢氧化铁的絮凝效果最好,絮体粒径为67.3 μm,铁离子去除效率为95.4%.【期刊名称】《广州化工》【年(卷),期】2018(046)019【总页数】3页(P78-80)【关键词】热镀锌;亚铁离子;过氧化氢氧化法;PAM【作者】于梦琦;党康飞;李顺义【作者单位】郑州大学化工与能源学院,河南郑州450001;郑州大学化工与能源学院,河南郑州450001;郑州大学化工与能源学院,河南郑州450001【正文语种】中文【中图分类】TQ电镀产业的生产是利用化学法或电化学法,在金属或其他材料的表面镀上金属[1]。
助镀液中的亚铁离子对镀锌工艺有消极影响,当助镀液中Fe2+含量过高,会使锌镀层发黑,镀液的分散能力下降,影响镀层质量,严重时使镀锌助镀液完全失效[2-3]。
研究表明,只有当铁离子的含量稳定维持在2000 mg/L以下时,才能保证镀锌取得较好的效果。
为了提高镀锌质量,实现最大限度的节锌,需要及时去除助镀液中的铁离子[4]。
目前,对助镀液中亚铁离子的去除方法有很多,主要有化学沉淀法、离子交换法、吸附法、电渗析、微电解法等方法[5]。
其中,微电解法、离子交换法等新型方法由于成本较高、操作时间长、设备复杂以及选择性低等缺点限制了这些方法的推广应用[6]。
化学沉淀法试剂来源广,成本低,金属离子去除率高,在实际操作中被广泛应用,但化学沉淀法产生的氢氧化铁沉淀量大,沉淀速度慢,不易从沉淀池中分离,沉淀时间过长会严重干扰后续镀锌,因此沉淀过程中需投加絮凝剂使氢氧化铁沉淀快速从助镀液中分离。
助镀剂助镀原理及检测方法.

第四章:助镀液(热镀锌工艺)简介现今助镀液是镀锌过程必要的一部份,但也有例外。
最早钢件以酸洗去除杂质和铁锈,之后直接浸入溶锌槽。
虽然此过程简单,但因耗锌量高、成本昂贵。
助镀液的导入,能使热浸镀锌业者降低钢件之锌层的厚度,改善成品品质,增加产能及降低成本。
4.2助镀剂(叁基盐和特殊的Tego60助镀剂)以热浸镀锌而言,钢件在经过脱脂、酸洗和水洗之后,助镀剂溶液本身是以氯化锌铵组成而发展出来的。
助镀液以不同比率的氯化锌与氯化铵混合而成:60% w/w ZnCl2:40% w/w NH4Cl -- 特殊的Tego1份ZnCl2:3份NH4Cl -- 叁基盐另外,添加润湿剂以改善助镀液的功能。
钢件氧化锌熔融锌液功用助镀剂有几点功用:1. 防止烘乾时钢件表面氧化。
2. 分解溶融锌液附着在金属表面的氧化锌层。
氧化锌产生是因为空气中的氧和溶融锌液之反应(450~460℃),当钢件浸入溶融锌时,气化锌层附着其上。
假如:金属表面形成氧化锌,则内层的锌铁反应将受很大的影响,将造成镀件的浸镀时间较原来长,时间加长,最终将增加钢件上锌层厚度。
氯化锌是易受潮所以优先吸收钢件表面水分,因此可防止浸过助镀液的钢件,在烘乾时生锈。
NH4Cl →HCl + NH3ZnCl2.2H2O + HCl →(HCl(OH)2)H2 + ZnCl2Hydroxy Acids ____(ZnCl2(OH)2H2+ HCl氯化铵在锌槽中会分解产生盐酸和氨水,盐酸会和氯化锌吸收的结晶水,结合产生两种Hydroxy酸(HCl(OH)2)H2和(ZnCl2(OH)2)H2 + HCl )。
此两种Hydroxy酸可以分解钢件表面所生之氧化锌层。
操作参数浓度助镀剂浓度决定在处理钢件的种类钢件种类o Be 波美’S.G 比重oTW比重线材7 ~ 13 1.05 ~ 1.10 10 ~ 20薄板13 ~ 19 1.10 ~ 1.15 20 ~ 30管材/一般热镀件19 ~ 24 1.15 ~ 1.26 30 ~ 52超大型钢/锻造件30 ~ 40 1.26 ~ 1.38 52 ~ 76以Be波美浓度28被认为可适用于各种钢件并得到最佳效果’温度助镀液的最适温度是60℃-65℃,温度较低,助熔剂附着会较不均匀且较没效果;温度较高,则助熔剂附着太厚,增加消耗。
镀锌在生产中锌合金镀层铁含量的在线检测

< 自动化 仪表) 2 卷第 4期 第 3
送 器 进 行 检 修 或 更换 。
一
20 02年 4月
为 10,的脏 污 高 炉 煤 气 检 测 中 , 于 增 加 了采 用 氮 0% 由 气 过 滤 反 吹 装 置 , 以较 好 地 解 决 以 往 在 均 速 管 测 量 可 中的 取 压 管 堵 塞 问 题 。
a u ot  ̄s m 0 ・ z cp i e ̄nml t f● q e 哪 i I n a, 目 r ' d
Ke y 0
 ̄. t- - h
po utnl ipeet rdc o i s rsne d
山 sc ot l Il ̄ lo sf a' f ot o elaea t evdh u honmlr[ t l u a as a_ f l p l x t f t e o] o e e0 c 畔 se t ogh i
体 化 均 速 管测 量 系统 方 框 图如 图 2所 示 一
星
4 结束语
钢 铁 厂 的 高 炉煤 气 测 量 由于 流量 大 、 径 大 、 速 管 流 低 , 是 相 对 湿 度 为 10 又 0 %的 脏 污 气 体 , 来 采 用 圆 缺 历 孔板计量 占绝大多数。我公 司在直径 为 2 m以 上 的 大 管道 高炉 煤 气 测 量 中 根 据管 道 位 置特 点 选 择 了 同心 圆 孔 板 和 一 体 化 均 速 管 流量 计 , 较 长时 间运 行 , 经 检测 数 据都 较 稳 定 ; 别 是 一 体 化 均 速 管 流 量 计 带 反 吹 装 置 特 成 功解 决 堵 塞 问 题 为 钢铁 厂 脏 污流 体 ( 炉 煤 气 、 炉 高 焦 煤 气 、 炉 煤 气 ) 流量 测量 开辟 了 良好 前 景 。 转 的
热镀锌的助镀液中除铁方法

热镀锌的助镀液中除铁方法(摘自热镀锌的节锌技术)除铁的重要性经常测定助镀液中Fe2+离子的含量并加以除去,控制在l g/L以内(国外控制在0.5 g/L以下)。
因为生成锌铁合金的因素是一份铁和25份锌。
这就是说生成锌铁合金所造成锌的消耗是大量的,因此除铁就显得格外重要。
经常分析助镀液中的Zn、NH4、Fe2+的含量并调整。
除铁技术除铁常用的方法有两种:一是将助镀液吸入除铁处理系统,通过加H2O2,将Fe2+氧化为Fe3+后再加入NH3·H2O中和到pH>5,然后由板框压滤机,滤清液回到助镀液槽中,滤饼集中存放处理。
这样的系统有搅拌器槽、双氧水槽、氨水槽和压滤机等设施组成。
另一种也可以定期在空槽中进行除铁作业。
通过分析铁的含量后,根据铁的含量多少加入H2O2和NH3·H20进行除铁作业。
如果暂时没有分析手段时,可首先取出少量助镀液在不断搅拌下加入选择量的H2O2 (30%),用NH3·H2O调节pH 为5以上,进行沉淀后将上清液再加入H2O2,如不发生浑浊现象则铁基本除完,然后计算H202加入助镀液中的数量。
一般情况下,H202(30%)的加入量为l2kg 左右可处理lT助镀液。
有时候一次处理完后分析或作试验时仍然有铁存在,要根据铁的多少,再次实施除铁处理,直至达到除铁效果Fe<lg/L。
如果铁的含量能够控制在0·5g/L时除铁效果将达到最佳状态。
NH2·H20的加入主要是靠测量助镀液的pH值而定量,如果处理前助镀液的pH值己超过5,那就可以不加NH3·H2O。
另外中和后一定要充分沉淀,使固液彻底分离,然后将上清液滤入助镀液槽中,并调节pH值4~5。
这项技术可使产生锌碴、锌灰的量减少,可达到平均节锌0·8%左右,对年产量大的热浸锌单位具有非凡的节锌意义。
除铁工艺流程:助镀液+氧化(30%H2O2)+中和(NH3·H2O)→静止→过滤→调节pH值→再生后循环使用。
助镀液铁离子检验

助镀液中铁离子含量检测
取1ml的助镀液,加入3ml的30%的过氧化氢(H2O2)再加入10ml水,加热至沸,冷却后加10ml(1+1)的氨水,过滤,并用10ml的(1+1)氨水洗涤沉淀,弃去滤液,把带有沉淀的漏斗置于一干净的250ml锥形瓶上,用10ml热的(1+1)盐酸洗涤于锥形瓶中,加热至沸。
加入6滴1g/L的甲基橙。
趁热边摇边滴加SnCl2溶液还原Fe3+至溶液变为粉红色,停止加SnCl2溶液,再摇几下至粉色褪去。
然后加入50ml水,15ml硫磷混酸(15+15+75),2-4滴二苯胺磺酸钠(5g/L),立即用K2Cr2O7标准溶液滴定至紫红色为终点。
c(铁离子)=C*V*55.85/a (g/L)
C---K2Cr2O7标准溶液的浓度mol/L。
V---消耗K2Cr2O7标准溶液的体积ml。
a---取样量ml。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
▋
天津大学学报 Journal of Tianjin University
Vol.42 No.10 Oct. 2009
热镀锌助镀剂中亚铁离子在线检测技术
马瑞娜,赵树鹏,曹晓明,温 鸣,李贺坤,杜 安
(河北工业大学材料科学与工程学院,天津 300130)
图 6 在线检测系统结构 Fig.6 Framework of online measuring system
在线检测结构由一个循环回路、一个数据采集通 道和信息反馈构成.由①②③④①构成助镀剂循环回 路;由⑤④⑥⑦构成数据采集通道;由⑦⑧构成信息 反馈.其中机械过滤除去杂质;微型蠕动泵给整个检
测系统助镀剂流动提供动力;单片机完成数据采集 与亚铁离子浓度计算并通过数码管显示浓度等功能. 3.2 主要硬件设计原理
本系统在分光光度法的基础上,通过光电效应将 透过被检测助镀液光强度变化转化为光电流信号变 化,再将光电流信号经过 I/V 转换电路转化为能够被 A/D 转换采集到的模拟电压信号,A/D 转换器将采集 的模拟电压信号转换成单片机能够识别的数字电压 信号,最后由单片机进行数据处理、浓度的计算及显 示等任务.
4,g/L 的 FeCl2 溶液;④pH<2,ρ[Fe3+ ] =1,g/L 的 FeCl3
溶液;⑤pH<2,ρ [Zn
2+
]
=200,g/L
的
ZnCl2
溶液;⑥pH<
ρ 2, [Zn2+ ] =200,g/L,ρ[Fe2+ ] =4,g/L 的助镀剂溶液;⑦pH<
2,ρ [Zn
2+
]
=200,g/L,ρ[Fe2+
·878·
天津大学学报
第 42 卷 第 10 期
佳),为连续清除助镀剂中铁离子提供依据,保证热镀 锌产品快速高质量的生产,满足现代社会市场经济下 高效率、高质量和低成本的要求.因此,笔者对热镀锌 工艺中助镀剂中铁离子浓度在线检测进行了研究.
剂溶液.光谱图如图 2~图 5 所示,其中图 2~图 4 的 扫描步长为 1,nm,图 5 的扫描步长为 0.5,nm.
对溶液中铁离子浓度的检测方法比较多,如化 学滴定法[6]、分光光度法[7-,8]、原子吸收光谱法[9]和目 前较为先进的单色冷光源技术、原子(离子)吸收和原 子发射光谱等技术.该类方法检测精度高,但是前处 理繁琐,成本高,只能够取样测定浓度不能实现在线 检测.并且目前关于铁离子在线检测的相关报道甚 少.在线检测的目的是使助镀剂中亚铁离子浓度控 制在某一个最佳值(即使助镀剂的触媒作用达到最
MA Rui-na,ZHAO Shu-peng,CAO Xiao-ming,WEN Ming,LI He-kun,DU An
(School of Materials Science and Engineering,Hebei University of Technology,Tianjin 300130,China)
下,以去离子水为参比,配制一系列标准溶液,分别测
定各种标准溶液的吸光度.以吸光度为纵坐标,以组
成浓度为横坐标做图,即得一条通过原点的直线,称
为标准曲线简图,如图 1 所示.
图 2 助镀剂中各种离子的光谱吸收图 Fig.2 Spectrograms of a variety of ions in flux
整体设计在低成本、小体积及可靠性高的原则下 选择以下主要硬件.
(1)选用单色性好,价格低,功耗低、发光效率高、 冷光源发光二极管为光源[11] .
(2)选用光敏范围在 400,~1,300,nm,暗电流小、 线性度好的红外光电传感器为光敏接收器.
(3)由于整个 I/V 转换电路的失调电压及漂移与 第一级有密切关系,因此选用具有超低失调电压和超 低漂移的仪器放大器[12]ICL7650 集成运放,而且第一 级承担仪器放大器的全部放大作用,必须保证 I/V 转 换的线性放大.因为第二级的漂移和失调电压对整 个电路的作用大大降低,但其共模抑制比 CMRR 对 整个电路的 CMRR 影响很大,因此第二级选用价格 更 为 低 廉 、性 能 也 较 优 越 的 低 漂 移 集 成 运 放 OP07.本电路因第一级增益较大,易引起自激振荡, 因此在 2 个 Rf 电阻两端加上 150,pF 的电容.微电流 放大器原理如图 7 所示,由 ICL7650 前置放大器和 OP07 电压放大器两部分组成 I/V 转换电路.R12 与 C19 用来滤去 ICL7650 的斩波尖峰噪声,C16 与 Rf 组 成反馈补偿网络,降低带宽,防止 Rf 以及 C19 相移产
图 7 微电流放大器原理 Fig.7 Microcurrent amplifier schematic diagram
·880·
天津大学学报
第 42 卷 第 10 期
生自激振,电阻 Rf 为了保证 I/V 转换的线性度,以提 高增益的稳定性和精度,减小噪声,此时第一级输出 电 压 U0=-ISRf , 第 二 级 放 大 电 压 U1=(R14/R13)·U0=(R14×Rf/R13)IS=8×106IS ,保 证 了 放 大 满 足 y=K0x 的线性度;当光电流最小为 IS=10-9 A 时,最 小放大电压 U1=8,mV.采用单片机控制,实现自动校 零以及过流保护.
图 5 pH<2 的助镀剂、FeCl2溶液和 FeCl3溶液的光谱吸收图 Fig.5 Spectrograms of flux with pH<2,FeCl2 and FeCl3 solutions
2009 年 10 月
马瑞娜等:热镀锌助镀剂中亚铁离子在线检测技术
·879·
分析图 2~图5 可知,助镀剂中的 H+、NH4+、Cl-、 Zn2+和 Fe3+等离子在波长 400 nm 以上都没有吸收 峰;Fe2+在 300~400 nm 和 700 nm 以上的两个光谱 范围都有吸收峰,但在 300~400 nm 内 Zn2+、Fe3+对 其有影响.故此,实验选用发光波长在 700,nm e3+
]
=0.1,g/L
的助镀
图 4 pH<2,ρ[Zn2+ ] =200 g/L,ρ[Fe2+ ] =4 g/L,ρ[Fe3+ ] = 0.1 g/L 的助镀剂溶液光谱图
Fig.4 Spectrogram of flux solution (pH<2,ρ[Zn2+ ] =200g/L, ρ[Fe2+ ] =4 g/L,ρ[Fe3+ ] =0.1 g/L)
3 在线检测系统设计
3.1 总体在线系统结构简图 根据热镀锌工艺酸性锌盐助镀剂的实际性质和
对助镀剂中 Fe2+在线影响因素分析,设计了在线检测 循环系统.在线检测系统结构如图 6 所示. 本系统 采用单色冷光为光源,红外光电传感器为光敏接收 器.助镀剂经过机械过滤后,对滤液进行分光光度分 析.通过光电检测信号处理、单片机处理及显示,计 算可知助镀剂中的亚铁离子含量.
收稿日期:2008-09-23;修回日期:2009-03-10. 作者简介:马瑞娜(1977— ),女,硕士,讲师. 通讯作者:赵树鹏,zhaoshupeng100@.
变 为 铁 盐 沉 淀 ,若 亚 铁 盐 含 量 太 高 ,就 只 有 排 放 重 配.然而如何保证亚铁离子含量保持在较低水平,需 要人工不定时地对助镀剂取样进行铁离子检测,此方 法不能保证连续生产和热浸镀高质量的要求.
表明,亚铁离子浓度在 0.1~10 g/L 范围内,检测误差小于 0.05 g/L,吸光度浓度线性方程相关系数 R=0.999 95.
关键词:助镀剂;亚铁离子;在线检测;自动化控制;分光光度分析
中图分类号:TP274
文献标志码:A
文章编号:0493-2137(2009)10-0877-07
Online Measuring Technology of Ferrous Ion in Flux of the Hot-Dip Galvanizing
摘 要:针对热镀锌助镀剂中亚铁离子对热镀锌产品质量的影响及其对在线检测的必要性,分析了热镀锌助镀剂溶
液的光谱吸收,并在分光光度分析的基础上,根据其光谱特点自行研制了一种亚铁离子自动检测仪,通过微型蠕动泵和
该检测仪实现了热镀锌助镀剂中亚铁离子的在线检测.该过程不需要对助镀剂进行其他预处理,操作简便、快速.结果
热镀锌助镀剂是氯化锌、氯化铵的混合溶液,助 镀剂中通常含有 H+、NH4+、Cl-、Zn+、Fe2+和 Fe3+,为
了分析各种离子的吸光光谱,分别对以下溶液进行光
谱研究(200~1,000,nm 波长范围内).①pH<2 的
HCl 溶液;②pH>5 的 NHCl3 溶液;③pH<2,ρ[Fe2+ ] =
使用溶剂法生产热浸镀 Zn-Al 合金是一种既经 济又简便的方法,助镀剂在热浸镀工艺中起着举足轻 重的作用.助镀剂中的亚铁离子对镀锌工艺有消极 影响[1-3],当助镀剂中 Fe2+含量太高,会使锌锅中的锌 渣量增加,影响镀层质量,严重时使镀锌用助镀剂完 全失效[4-5].研究表明,只有当亚铁离子的含量稳定地 维持在 2.0 g/L 以下时,才能保证不会出现漏镀、疤刺 等镀锌缺陷.为了保证连续稳定地将助镀剂中亚铁 离子含量保持在较低的水平,从而实现最大限度的节 锌和改善工件的镀锌质量,需要及时清除助镀剂中的 亚 铁 离 子 .目 前 的 方 法 是 将 助 镀 剂 的 温 度 加 热 到 85,℃以上,加入 H2O2 氧化剂和 NH4Cl,使亚铁盐转
Abstract:Because of the significant effect of ferrous ion in flux on the quality of hot-dip galvanizing products and the necessary of the online detection of ferrous ion,the spectral absorption of the ferrous ion in flux has been investigated in this paper. Based on spectrophotometric analysis,the automatic detection equipment for ferrous ion has been developed according to its special characteristics. Online measuring of ferrous ion in flux of the hot-dip galvanizing has been achieved with micropump and the equipment,which is simple,rapid and does not need pretreatment of the flux. Experimental results show that the measuring error is less than 0.05 g/L and the linear equation of the absorption and concentration of the ferrous ion shows a good related coefficient of 0.999 95(R = 0.999 95) when the ferrous ion concentration is between 0.1 g/L and 10 g/L in the flux. Keywords:flux;ferrous ion;online measuring;automated control;spectrophotometric analysis