海尔施特劳斯智饮机产品介绍

合集下载

美国海尔电器有限公司产品说明书:Cascade Contour 浴池系统

美国海尔电器有限公司产品说明书:Cascade Contour 浴池系统

Cascade ContourBathing Systems with Aqua-Aire® Installation / Assembly Instructions360745C Revision A – 05/01/2013ContentsINTRODUCTION (3)TERMINOLOGY AND SYMBOL MEANINGS (3)PLUMBING REQUIREMENTS (3)SYSTEM CONTROLS CASCADE CONTOUR SPA (4)ROUGN-IN SPECIFICATIONS FOR RIGHT HAND CONTOUR SPA (5)ROUGN-IN SPECIFICATIONS FOR LEFT HAND CONTOUR SPA (5)CASCADE CONTOUR WITH SIDE ENTRY TUB SPA (6)CASCADE CONTOUR WITH END OPENING SPA (7)CASCADE CONTOUR WITH SWIVEL LIFT TUB SPA (8)DRAIN REQUIREMENTS (9)HOT AND COLD WATER SUPPLY REQUIDREMENTS (9)ELECTRICAL REQUIREMENTS (9)UNPACKING THE CONTOUR TUB (9)UNPACKING THE CONTOUR CABINET (9)ASSEMBLY AND INSTALLATION OF THE TUB AND CABINET (10)ANCHORING THE CADSCADE SWIVEL LIFT TUB (11)ANCHORING THE CASCADE CONTOUR CABINET (11)WATER SUPPLY AND DRAIN CONNECTIONS (12)DRAIN REQUIREMENTS (12)HOT AND COLD WATER SUPPLY REQUIREMENTS (12)ELECTRICAL CONNECTIONS (12)SYSTEM CHECKS (13)FINISHING UP (14)INTRODUCTIONThese instructions are for the installation of the Cascade Contour Bathing System Cabinets and Tubs. The Reservoir is included in the cabinet of this system, which is to be pre-filled prior to placing the resident into the tub. Then the water in the reservoir can be released into the tub. This shortens thetime required before the tub is full.When the terms “left” or “right” are used with refer ence to the tub, this means left or right as youlook at the control panel from the seat end of the tub.TERMINOLOGY AND SYMBOL MEANINGSMeaning: Safety warning. Failure to understand and obey this warning may result in injury to you or to others.Meaning: Failure to follow these instructions may cause damage to parts or systems.Note: Refer to the “Tub Controls” figure 1 on page 4 of this manual for the location of any of the controls referenced.PLUMBING REQUIREMENTSIt is required that a licensed plumber make all plumbing connections. He can select the best method of connection and if Reduced Pressure Zone Backflow Preventers are required.SYSTEM CONTROLS CASCADE CONTOUR SPAROUGN-IN SPECIFICATIONS FOR RIGHT HAND CONTOUR SPAFigure 2ROUGN-IN SPECIFICATIONS FOR LEFT HAND CONTOUR SPAFigure 3CASCADE CONTOUR WITH SIDE ENTRY TUB SPAFigure 4Top ViewFigure 4CASCADE CONTOUR WITH END OPENING SPAFigure 5CASCADE CONTOUR WITH SWIVEL LIFT TUB SPAFigure 6DRAIN REQUIREMENTSFigure 2 shows two different options for roughing in the drain pipe – from the floor or from the wall. The tub is equipped with a 2” nominal (2 3/8” O.D.) PVC drain pip e.NOTE: It is required that a licensed plumber make all plumbing connections. He can select the best method of connection for the particular situation and determine if ReducedPressure Zone Backflow Preventers are required.HOT AND COLD WATER SUPPLY REQUIDREMENTS3/4” supply lines with on/off valves with 3/4” NPT Male threads. We recommend 3/4” ball valve with 3/4” NPT female ports. (Valves supplied by others.) See figure 2 for recommendedlocations.For optimum performance, dynamic pressures should be nominally equal between hot and cold supplies.Maximum static supply pressure: 145 PSI.Maximum dynamic/maintained supply pressure: 81 PSI.Maximum supply Hot water temperature: Consult local requirements for maximum allowed supplytemperatures. (Not recommended over 120o F)ELECTRICAL REQUIREMENTSThe Cascade Contour tub Aqua-Air is rated at 7.25 Amps (9.5 Amps for Swivel lift tubs), 120 Volts AC.15 amp GFCI circuit is required.UNPACKING THE CONTOUR TUB1. Remove the Tub from the shipping crate.2. Locate and save the installation parts.UNPACKING THE CONTOUR CABINET1. Remove the Cabinet from the shipping crate.2. Locate and save the installation parts.3. Remove the Top or lid, and the two end panels and place to the side out of the way.ASSEMBLY AND INSTALLATION OF THE TUB AND CABINET1.Place the cabinet approximately 2 feet from the wall directly in front of the intended finallocation.2.Move the tub directly in front of the tub with the foot end of the tub just in front of the tubopening in the cabinet.3.To avoid damaging the seal at the top of the tub opening of the cabinet, tip the cabinet back andthen slide the tub into the opening of the cabinet. Lower the cabinet back down.4.Connect the tub and cabinet frames together with the bolts, flat washer, and hex nuts provided.Use the flat washers under the heads of the bolts and under the hex nuts to protect the powder coated finish of the frames. Note: Some adjustment of the leveling feet of the tub may beneeded to align the bolt holes in the frames.5.Connect the air manifold of the tub to the union connection of the cabinet plumbing locatedinside side panel behind tub.6.Connect the tub temperature probe to the tub at the probe fitting in the foot well of the tub justabove the drain outlet. Tighten the compression nut slightly. Further tightening is needed only if the connection leaks with the tub full of water.7.Connect the clear 3/8” I.D. drain tube from the bottom of the air system check valve to the barbfitting located on the tub drain base shoe. Secure the connection with the provided clamp.8.Connect the overflow fill of the cabinet reservoir to the overflow of the tub and tighten.9.With the help of 2 or 3 additional people, slide the cabinet and tub into the final location. Note:The leveling pads of the tub have non-skid pads on them. So it is not easy to slide. Picking up on the tub as it is pushed helps. The tub and cabinet are heavy and are not easy to move.10.Anchoring the tub to the floor is not required except on the built in Swivel Lift tub. The SwivelLift tub must be anchored to the floor.11.Anchor the Cabinet to the floor with anchors provided.12.Connect the Swivel lift power to the tub electrical kit.ANCHORING THE CASCADE SWIVEL LIFT TUBWarning:The Cascade Contour Tub with the built in Swivel lift System must to be anchored to the floor. Failure to anchor the Built in Swivel Lift Tub to the floor could result in injury to the operator or resident.Note:These instructions for anchoring the swivel lift tub are written with the assumption that theinstallation is being done on a concrete floor. If this is not the case, consult an Architect. There are three anchoring locations, two at the control end, and one at the seat end of the tub (see Figure 7). Anchoring the Reservoir is not necessary.1. Remove the end panel, at the seat end of the tub, and set it to the side.2. The tub is heavy and is not easy to move. Picking up on the tub as it is pushed helps. With the helpof 2 or 3 additional people, place the tub/cabinet in the final installation position. 3. The leveling bushings are to be adjusted and can be done with a ¾” socket as show in Figure 7. 4. Using a 3/8” masonry bit, drill through the one leveling bushing into the concrete floor as shownin Figure 7. (2” deep) 5. Clean the drilled holes and clean the drilling dust from the area.6. Insert the provided 3/8” anchor through the leveling bushing and into the anchor hole jus t drilled.7. Tighten the anchor nuts.8. Re-install the end panel on the tub.ANCHORING THE CASCADE CONTOUR CABINETFigure 8 figure 9Anchor the Contour Cabinet in the two locations illustrated in figure 8 and figure 9 above.Figure 7Bushing Alternate hole locationAlternate hole locationFig. 10 Tub Electrical BoxWATER SUPPLY AND DRAIN CONNECTIONSNote: Every installation is different. So the connecting fittings and the p-trap are not provided with the tub. A licensed plumber is required to make the drain connection.1. Connect the tub drain outlet to the drain pipe.2. The connecting fittings with the connecting hoses are provided. Do not open The Supplyvalves yet.DRAIN REQUIREMENTSThe tub is equipped with a 2” nominal (2 3/8” O.D.) PVC drain pipe. As shown in Figure 2 (RH), Figure 3(LH) of page 5, the tub ’s drain pipe is approximately 10” from the wall and 5 1/4” above the floor. Figure 2 & 3 shows two different options for roughing in the drain pipe – from the floor or from the wall.It is recommended that a licensed plumber make all plumbing connections. He can select the best method of connection for the particular situation.HOT AND COLD WATER SUPPLY REQUIREMENTS3/4” supply lines with on/off valves with 3/4” NPT Male threads. We recommend 3/4” ball valve with 3/4” NPT female ports. (Valves supplied by others.) See Figure 2 (RH), Figure 3(LH) of page 5, for recommended locations. For optimum performance, dynamic pressuresshould be nominally equal between hot and cold supplies. Maximum static supply pressure: 145 PSI. Maximum dynamic/maintained supply pressure: 81 PSI. Maximum supply Hot water temperature: Consult local requirements for maximum allowed supply temperatures. (Not recommended over 120°F)ELECTRICAL CONNECTIONSWarning!This unit is to be connected only by a licensed electrician. A minimum of 20 amp 120 volt service is required with ground fault circuit interrupter. 1. Remove the cabinet’s electrical box cover and locatethe connecting points within the box. See figure 10.2. Ensure that the supply power has been turned OFF.3. Connect the power cord from the tub lift electrical boxto the cabinet electrical box (figure 10). Black to line bar, white to neutral bar, green to ground bar.4. Run flex conduit and power wires from the wallmounted supply box to the connection hole of theelectrical box located on the upper left side of the box.5. Connect the line, neutral and ground wires to the appropriate connections within theelectrical box. A female wire terminal is provided for connection of the line wire to thetub circuit breaker.6. Replace the electrical box cover and turn off the tub’s circuit breaker on the top of thebox.7. Turn ON the supply power.8. Switch ON the tub circuit breaker. All the temperature gages located inside the upperright hand door of the cabinet should now be lit up.9.The tub is now ready to be checked for leaks. Turn off the tub circuit breaker. SYSTEM CHECKS1. Ensure that the tub water door is closed.2. Turn ON water supply valves and check for any leaks. Tighten any leaky connections asneeded.3. Switch ON the tub circuit breaker and switch off any water valves or the blower if theyare ON by way of the control panel buttons.4. On each of the water systems (Tub Fill, Reservoir Fill, Disinfect Jets, Rinse Jets, andHand shower), and checking only one system at a time, turn ON the valve by pressing the appropriate control panel button. Look for any leaks and tighten connections as needed.Note: The hand shower needs to be directed into the tub before starting it.5. Place the drain plug in the drain and partially fill the tub. Remove the drain plug andcheck the drain system for any leaks and repair if needed.6. Close the reservoir (release) valve by moving the “Reservoir Valve” lever to the closedposition. Place the drain plug in the tub drain and fill the reservoir by pressing the“Reservoir Fill ON” button. Watch the “Fill - Shower” temperature read out and adjustthe mixing valve to get the desired temperature. The “Reservoir Temperature” read-outindicates the temperature of the water already in the reservoir.7. Wait until the reservoir stops filling. Should it stop filling before the water level in thereservoir reaches the float switch, then the timer, within the electrical box needs to beadjusted to a longer time. The float switch is the primary system to turn OFF the reservoir fill. The timer is a back up system in the event that the float switch fails.8. Check for any leaks.9. Release the reservoir water into the tub by moving the “Reservoir Valve” lever to the“Open” position. Check for any leaks in that plumbing.10. With the tub nearly full, check that there is no leaking around the temperature probe ofthe tub. Tighten the compression fitting if needed.11. Start the Aqua-Aire blower by pressing the button. Note: The blower takes a few secondsto start and winds up to full speed somewhat slowly. This is normal. The bubbles should start flowing from each of the jets in the bottom of the tub shortly there after.12. Stop the blower and drain the tub.13. Install the end panels and the cabinet top.FINISHING UP1.Once the tub/reservoir has been connected to the drain, checked for leaks (and fixed ifneeded), and is connected to power, the access doors can be installed.2.Train all operators of this equipment before using it per the Safe Operation & DailyMaintenance Instruction Manual.Warning!Because this equipment requires a trained operator, and to assure that these benefits are realized, d o not operate your PMI equipment until an authorized member of your staff has reviewed the Safe Operation & Daily Maintenance Instruction Manual and spoken to your PMI Representative. Failure acquire this training could result in damage to the equipment or injury to the operator and resident. If needed,Your PMI Products Representative will assist you with questions you may have in the operation of this equipment.。

海尔 HWP25-G(WH)管道式中央净水机 使用说明书

海尔 HWP25-G(WH)管道式中央净水机 使用说明书

市政自来水 0.1MPa~0.4MPa 0.1MPa~0.4MPa
图片区5域℃~38℃
≤90%
环境温度
4℃~40℃
净水流量 额度
总净水量 卫生许可 批准文号
出水水质
8.3L/min 30000L
执行标准
16.6L/min 50000L
33.3L/min 100000L
41.6L/min 130000L
体现海尔真诚、贴心的服务,海尔友情提醒您: 海尔产品安装服务,因用户的安装环境、个性需求不同,安装过程中如需
辅加材料或有特殊服务项目支付材料费,具体付费请参照服务工程师出示的 《服务收费指导价格标准手册》。如服务工程师不按标准收费或服务规范执行 不到位,请拨打海尔全国客服电话4006 999 999或登录海尔自助服务专区 评价、投诉。经核实无误,本次服务“免单”。
维护保养
故障诊断及排除
当产品出现故障时,请采取以下步骤或与当地经销服务网点联系予以排除。
故障现象
产水量下 降很多
原因 滤芯被堵塞 水压过低
解决方法 需要进行清洗或更换滤芯,请与 当地经销服务网点联系
采用增压措施
出水水质差 漏水
滤芯失效
长期停用(停用时 间>3天)
接头损坏
请与当地经销服务网点联系, 及时更换滤芯。
海尔,期待您的参与!
如果您的产品有服务需求,欢迎体验海尔自助服务专区 ,在线安装、报修。
8
环保清单
标记“×”部件在废弃后, 如处理不当,会对环境造成污染,也会造成资源的浪费。
产品中限用物质的名称及含量
部件名称
铅(Pb)
金属件

塑料件

滤芯组件

海尔 YRZ07S-CBU1 立式热饮机臻饮系列 使用说明书

海尔 YRZ07S-CBU1 立式热饮机臻饮系列 使用说明书

使用说明书型号YD2108S-CBU1 YDZ07S - C BU1 YDZ08S - CBU1 Y D2202S- C BU1 YD2206S- C BU1 YD2208S-CBU1 YDZ22S-CBU1 YDZ26S-C BU1 YDZ28S- C BU1YD2108S-CBU1(LP)饮水机(热饮机)智能家电操控智慧场景定制智家商城购物家电报装报修YR2108S-CBU1 YRZ07S - CBU1 YRZ08S - CBU1YR2202S - C BU1 YR2206S - C BU1 YR2208S - C B U1 YRZ22S -CBU1YRZ26S- C BU1 YRZ28S-C BU1YR2108S-CBU1(LP)目录使用注意事项.......................................1产品简介............................................. 2.产品部件..........................................2.装箱清单..........................................2.技术数据..........................................3.电气原理图......................................4.产品特点..........................................4.产品功能..........................................4安装及维护..........................................6.固定说明..........................................6故障诊断及排除...................................9使用指南.............................................8环保清单...........................................11.产品中限用物质的名称及含量.........11产品中与水接触材料列表..................11保修服务............................................12.用户须知........................................12.保修说明.......................................12“1+5”成套服务 (13).温馨提示..........................................7.清洁保养..........................................7.安装方法 (6)尊敬的用户:您好!为保证使用安全,防止人身伤害及物品损坏,使用本产品前请务必仔细阅读本说明书并遵守所有注意事项。

海尔施特劳斯净水器日常使用问答

海尔施特劳斯净水器日常使用问答

海尔施特劳斯净水器日常使用问答关于净水器可能你看到过很多相关的信息和新闻报道,现在家庭确实需要安装一个净水器,就只是为了家人的健康也需要安装净水器,现在净水器品牌确实有很多,这样普通消费者难以选择,购买家用电器当然还是选择大品牌,海尔施特劳斯专业做净水器,专业才能给消费者提供更好、质量更有保障的产品。

关于海尔施特劳斯净水器,下面这些问题你了解吗?Q1:最近听说桶装水不安全,很多家庭都开始安装净水器了,真的是这样吗?家用净水器该怎样选择呢?A:我家装的就是净水器,身边也有很多朋友和邻居也都是净水器,现在新装修房子的都会选择安装净水器而不是饮水机,反正我这边是这个情况,不知道楼主那边是什么情况。

我家装的是海尔施特劳斯智能U3(N)净水器感觉挺不错,楼主可以关注一下这个品牌。

Q2:海尔施特劳斯智能U3(N)净水器真的有那么好吗?朋友一直向我推荐,有用过的吗?说说具体怎么样?A:这个净水器真的很好,因为我家装的就是这个,它属于厨下智能净水设备,不仅体积小巧,安装方便,关键是好用。

它采用的MAZE-T过滤技术已经独获世界级多项专利和认证,更换滤芯也非常方便,不需要工具,一键弹出即可更换。

具体的你也可以参照海尔施特劳斯官网的介绍。

Q3:最近听到好几个朋友说家里装智饮机了,也想买一个,海尔施特劳斯智饮机怎么样?A:海尔施特劳斯智饮机很不错,最近新出的一款立式L5智饮机更是好用,不仅外观高档大气,最重要的是它能够满足全家人的饮水需求,因为它有五档水温设置,有冰水、室温水、婴儿配方水、个性化水以及沸水,不论你需要什么温度的水都能够一键取得。

海尔施特劳斯的净水装置都很不错,它所采用的MAZE 过滤技术已经独获世界级多项专利和认证,海尔施特劳斯的产品值得推荐。

Q4:家里装净水器有必要吗?最近看身边很多朋友和邻居家里都装净水器了,也想安装个净水器了A:我觉得很有必要,毕竟现在水污染严重,没装净水器之前每天早晨刷牙总感觉自来水有股漂白粉的味道,装了净水器之后口感特别好,我用的是海尔施特劳斯净水器,感觉非常好用。

海尔施特劳斯U3净水器安装指南

海尔施特劳斯U3净水器安装指南

8.2把机器固定在 支架上,若未卡到 位,打开外盖按此 位置重新卡到位;
出水
进水
8.3用3/4转换接头 将前置过滤器出水 管连接到进水阀上; 用快速接头将出水 龙头水管连接到出 水阀上;
8.4将电源线和龙 头电线连接到机器 上;
安装步骤
安装示意图
安装步骤
9 通电试机:
8.1打开水 龙头开关, LED指示灯 为蓝色;
• 一直显示蓝色表示机器正常运转 • 蓝色闪烁表示滤芯快要用完(10%剩余提醒) • 一直显示红色表示滤芯已用完,机器已停止使用
MAZE –T 滤芯
• 向用户展示机器,并说明如何更换滤芯,用户需自行更 换滤芯
前置活性炭滤 • 向用户说明如何更换前置过滤器活性炭滤芯,用户需自

行更换滤芯
謝謝
8.2等水从水 龙头出来并且 持续两分钟, 以清洗滤芯
8.3检查所 有机器连接 处是否有漏 水
8.4关掉水龙头, 确认一秒钟后没 水再滴出
指导用户使用
三通阀
• 向用户说明三通阀位置 • 向用户说明如有漏水如何关闭三通阀
通电,试机;• 向用户说明出水龙头开关操作及解释LED指示灯用途
出水龙头和LED 指示灯


不能安装
正常安装
安装减压阀 不能安装
5 安装前置过滤器:取下水压表,在三通阀上装上前置过滤器(提前将
活性炭滤芯装入滤瓶中)
6 水盆或台面打孔:尽量利用水盆上现有的孔,若没有则需在水盆或台
面上打一个18mm的孔,用于安装水龙头,注意不要打坏台面,损坏其 他设备。
安装步骤
7 安装出水龙头;
7.1在水 7.2装在水 龙头上套 盆或台面 上LED指 的孔内; 示灯和垫 圈;

海尔 HRO7572-CJ 增压自吸净水机 使用说明书

海尔 HRO7572-CJ 增压自吸净水机 使用说明书

使用注意事项
尊敬的用户: 您好!为保证使用安全,防止人身伤害及物品损坏,使用本产品前请务必仔细
阅读本说明书并遵守所有安全注意事项。 1. 本产品的安装、维护及保养必须由售后服务网点专业人员进行实施,方可保障产 品正常运行。未经售后服务网点专业人员进行安装、维护及保养,导致机器无法达 到正常状态或性能时,我公司不承担责任。 2. 当遇到停水或管道维修时,请关闭电源和进水三通球阀;恢复供水时,请先打开 其他水龙头排尽泥沙后再打开三通球阀,否则大量泥沙可能导致滤芯堵塞。 3. 如果电源软线损坏,必须用专用软线或从其制造商或维修部买到的专用组件来更换。 4. 反渗透膜的过滤产水流量会受水质、水压和水温的影响。当水质不符合标准、水 压过低、水温小于(25±1)℃时,产水流量将小于标准值。 5. 浓缩水“浓水或废水”可回收利用,不可直接用于饮水,可选择性地用于家庭用 水(浇花等)。(为避免漏水,建议在售后当地网点的指导下进行固定回收管路) 6. 为了保护滤芯,机器长时间待机后会出现短时间冲洗动作,冲洗时会伴随一定噪音, 这个属于正常现象。 7. 测试水效等级时请以关闭纯水出水的方式进行测试(因设计有长时间制水保护功能需 要在4小时内关闭一下水龙头)。 8. 出水龙头关闭后,长时间会流出几滴水,是管路中的尾水积累渗出,是正常现象。 9. 若用户家中未接通自来水,安装本产品时必须使用相配套的过滤自吸头(用户需自行 采购)。
6
安装及维护
② 三通球阀
接其它龙头 或封闭
水管接头


PE管 (接进水口)
4. 快速接头的安装连接
产品的进、出水口都有快速接头端口。快速接头是一种不需要工具就能实现快速 牢固连接的接头端口。首先拔出端口处U型固定卡环,将端口表面可活动的塑料圈压 向端口,使之与端口相贴就可轻易拔去喇叭型塑料柱塞。将PE管插入接头端口到底, 再向外轻拉一下,使端口表面活动的塑料圈与端口留出一点缝隙,把U型固定卡环插 入缝隙即可。

haier商用机和开水器产品介绍

haier商用机和开水器产品介绍

方案四: 净水器+ 管线机
场所5: 办公场 所
场所6: 房地产
+
方案五: RO+管 线机
9
何为商用净水? 所有居民家用以外的净水设备都 可以叫做商用设备! 具体分:商用净水、商用饮水
10
11
2.海尔商用净水机分析:产品卖点
价位段
40000
30000
25800
29800
20000
15800 13900 9980
3
长春宝钢200G
RO机
4
长春宝钢集团开水平台
5
朝阳区洗手液厂
6
长春铁北酱油厂
7
长春市火车站开水平台
8
1. 海尔商用净水机分析 用户场所
方案一: 商务直饮 机 方案二: 净水器+ 开水器 场所1: 机场、 车站 场所2: 酒店、 餐厅 场所3: 学校、 工厂 场所4: 医院
方案模块
方案三: 开水器 (带超滤)
6、双温度频道,热水、温水可根据需要饮用,温热水龙头可按需定制
3.2.1 海尔开水器产品介绍卖点
型号 额定电压 额定功率 容量 出热水流量(L/H) 进水水源 适用人数 过滤系统 外形尺寸(mm)
HKP023-W 220V~ 3000 26L 30L(热水)/150L(温水) 市政自来水 100 无 890*390*1080
27
3.2.2主销型号简介(8)
型号:HKP032-L 最大优势(1) 采用高效热交换系统,节能环保,省电80%
21
3.1.5 主销型号简介(5)
型号:HKB039-R
最大优势(1) 步进式加热技术,五防安全技术
★ 步进式加热,即开即饮鲜活水

海尔电子(Haier)饮水机用户手册说明书

海尔电子(Haier)饮水机用户手册说明书

Adding special salt
To avoid damage to the appliance, only add special salt to the dispenser for special salt just before the programme starts. 1. Unscrew the lid of the dispenser for special salt
Adding detergent
1. Add the detergent to the dry detergent dispenser.
50 ml
2. Close the lid of the deter-
25 ml
gent dispenser.
15 ml
a The lid clicks into position.
Eco 50°
1) 4:35 2) 0,736 3) 9,5
Silence 50°1
1) 4:00 2) 1,050 3) 11,0
Express 65° - 1h
1) 1:00 2) 1,300 3) 10,5
Machine Care
1) 2:10 2) 1,350 3) 15,2
Favourite
6. Re-assemble the filter system.
7. Insert the filter system into the appliance and turn the coarse filter clockwise. Make sure that the arrow markings match up.
Hardness mmol/l range来自Setting value
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

謝謝
青岛海尔施特劳斯水设备有限公司 山东省青岛市崂山区海尔路1号海尔园R座 联系人: 张艳花 手机: QQ: 2529658205 邮箱:zhangyanhua@
产品示意及产品定位
金属质感表面
圆形盖子, 简 约干净
曲线设计,精 美迷人
接水槽, 全 心全意为用户 着想
可拆卸上盖
LCD, 让饮水机 看起来先进高档
灯光设计,帮助消 费者确定出水位置
表面可拆卸的支 撑设计
行业领先
——采用全球独创 “MAZE”技术并 引领行业标准
即需即饮
——My Water技术,实现即需即饮
感官处理 (口感、味道、去除率) 去除有机化合物 (材料:颗粒活性炭)
去除细菌病毒 (材料:抗菌性聚合树脂)
“一次到位”的净水处理
进水口
出水口
滤芯使用效期显示器
自动截流阀 重金属去除介质 去除挥发性的有机污染物,并改善 味道和气味 砷(杀虫剂/除草剂)去除介质
微生污染物去除介质
智饮机独特优势:
安全
节能
环保
鲜活
健康
便捷
核心技术(MAZE™ Purifier)
产品描述:此滤芯是一款重力给料的装置
有效滤除水源中:
同时能够保留:
细菌&病毒
有益物质(如钙、镁等)

重金属(如镉、汞、铅、铜等)

异味
此款产品的颜色为:经典银、酒红色和珍珠白
MAZE 技术
去除砷 (材料:离子交换树脂)
去除重金属铜、汞、镉 六价铬、铅 (材料:重金属吸附树脂)
产业解决方案
——从家用净水到商用净水及便携式 净水的全面解决方案
以家用饮水需求为核心,通过产品创新、商业模式创新及机制创新,为中高端用户 提供“即需即饮、无级变温”的革命性的健康饮水解决方案。
Safety Saving Energy Friendly to Environment Freshness Health Convenimple、快速Speedy 、同步Same、惊喜Surprise 2)双水源设计,两种进水方式,根据需要摆放不同位置 3)产品由英国顶级设计公司seymourpowell设计 4)滤芯更换装置,操作简单,滤芯更换便捷(就像DVD换碟片),滤芯获取方便 5))接水定位灯保证接水安全 6)儿童锁双重锁定功能
•健康安全 1)以色列原装进口MAZE滤芯 2)滤除细菌杂质、保留有益物质 3)基于流量控制的滤芯达到260升后自动关闭 4) RFID技术保证滤芯与机器对应,防止假冒伪劣 5)WQA 和CDC的强势保证 6)即需即饮,拒绝“千滚水”,保证饮水鲜活 •无极变温 1) 可预设5档温度频道,一键用水。 2) 冰水、婴幼儿水专用频道、室温水、个性化水、热水频道提供选择 3) 6°-沸水变温,满足不同饮水需求(泡各种茶、冲咖啡、冲奶粉等)
相关文档