瑞士万通离子色谱仪800 Dosino进样器说明书--英文
瑞士万通离子色谱仪800 Dosino进样器说明书--中文

800 Dosino –开始参数标签: 方法▶设备▶ Dosino溶液Select the solution for the Dosino that should be available when the hardware is started with [Start HW]. A check is carried out in the method run to ensure that the correct solution has been put on the dosing device. When the method is started, the working life and GLP test interval are checked for the selected solution.选择未定义 | Solutions from the solution table默认值未定义未定义The solution is not checked.Solutions from the solution tableOnly "intelligent" solutions, i.e. solutions that are assigned to an 807 Dosing unit, can be selected.ConnectorShows the main device and the MSB connector which the 800 Dosino is on.800 Dosino –命令Overview of the time program commands available for the 800 Dosino: 加液对话窗口:方法▶时间程序▶编辑▶‘设备’–加液The device-dependent time program command Dosing (command with feedback) doses the specified volume via the defined port. There is no automatic filling beforehand or afterwards.参数PortPort via which dosing takes place. Formula input possible.1 (4)范围默认值 1V olumeVolume to be transported. Formula input possible.范围0.0000 ... 99999.9000 mL默认值 1.0000 mLDosing rateSpeed at which discharge takes place. The 最大值 rate depends on the cylinder volume of the buret used. Formula input possible.Cylinder volume 2 mL范围0.01 ... 6.00 mL/min默认值 1.00 mL/min选择最大值Filling rateSpeed at which filling takes place. The 最大值 rate depends on the cylinder volume of the buret used. Formula input possible.Cylinder volume 2 mL范围0.01 ... 6.00 mL/min默认值 1.00 mL/min选择最大值命令时间程序命令的可选注释。
万通型自动进样器安全操作及保养规程

万通型自动进样器安全操作及保养规程引言万通型自动进样器是一种精密的分析仪器,可用于化学分析、药学、生化、环境、食品、农业等领域。
正常操作和合理保养能保证该仪器的良好性能和寿命。
本文档将重点介绍万通型自动进样器的安全操作规程和保养维护方法,以保证仪器的正常使用和安全运行。
安全操作规程1. 仪器准备在使用自动进样器前,需要进行以下准备工作:•检查仪器及所有连接点是否正常;•按照使用说明书或操作手册正确接线;•检查仪器供电是否正确;•检查样品是否准备好。
2. 样品进样在使用自动进样器进行样品进样时,需要注意以下事项:•样品必须按照规定的样品量进样;•不得将腐蚀性、有毒、易燃、易爆等危险性样品直接进入自动进样器;•在进行样品进样前,必须确认样品是否与进样装置匹配。
3. 进行分析实验在进行分析实验时,需要注意以下事项:•不得在自动进样器内进行任何更改或维修;•在实验过程中,应注意观察自动进样器的运行状态,及时排除故障;•不得在自动进样器上违规接线或尝试修改参数。
4. 停止使用在停止使用自动进样器时,需要注意以下事项:•按照说明书或操作手册要求,正确地进行停止操作;•断开电源并关闭所有开关。
保养维护方法1. 周期性检查在自动进样器安装完毕后,需按照检查周期进行检查:•每日检查:检查固定连接点是否松动、仪器供电是否正常;•每周检查:检查管路是否有沉积物或淤积物,清理仪器内部;•每月检查:检查所有元件是否正常,对元件进行清洗或更换。
2. 贮存和保养在长期不使用自动进样器时,需要注意以下事项:•断开电源,并清洁外观;•将仪器拆分并妥善贮存。
3. 维修保养在自动进样器出现故障或异常情况时,应按照以下要求进行维修保养:•保持现场整洁;•确认维修人员的资质和技能;•在操作时,注意自身安全,并遵守相应的操作规范;•经过维修后,应按照规范认真进行验收,确保维修结果良好。
总结万通型自动进样器是一种高精度的分析仪器,需要严格遵守规范进行安全操作并按时进行保养维护,以确保其正常、安全、环保、高效地使用,能够有效地增强实验的精度,为科学的研究工作提供有力的支持。
瑞士万通滴定仪808、809 使用简介

808/809 使用简介1. 准备工作1.1. 如果您曾经断开过电缆连接请按以下顺序连接:将6.2151.000 PC 连接电缆一头插在809后面板的controller 插口上,另一头插入PC 的USB 口。
将搅拌器的插头插入809后面板的MSB1~4 插口中的一个上,记下序号。
将管路连接好(如果拆下来过)。
如果800Dosino (加液器)连接在Dosing unit (加液单元)上,将Dosino 逆时针旋转至其上的实线与Dosing unit 上的虚线对齐,取下。
将800Dosino (加液器)连接在Dosing unit (加液单元)上,将Dosino 逆时针旋转至其上的实线与Dosing unit 上的实线对齐。
如果该单元是第一次启用,屏幕上会显示出如下信息框,“检测到一个新的交换单元或加液单元,在使用前您应该在”System/Titrants”菜单下对其进行设置。
”点击 [OK] 确认。
如果该交换单元或加液单元已被设置过,但仪器内相应记录已被删除,屏幕上会显示出如下信息框:“是否将滴定剂数据传送到滴定剂记录表中。
”点击[YES] 将单元内的数据复制到滴定剂记录表内。
如果至少有一个Dosing unit(加液单元)连接在800Dosino(加液器)上,屏幕上会显示出如下信息框:“请运行Prepare 功能,您可在”Manual control / Dosing”菜单下找到该命令。
”点击 [OK] 确认。
接下来屏幕上会显示出主操作画面,您可以开始进行分析工作。
1.2. 主操作画面画面上部是菜单,右侧是固定功能的操作键,固定操作键的功能如下: [Print]: 手动打印报告。
[Manual]: 手动操作。
[Home]: 从任何画面回到主操作画面。
[Back]: 回到前一画面。
[Stop]: 中止方法的运行。
[Start]: 启动方法的运行。
左面其余部分是对话框,对话框下部按钮的数量、名称和功能随对话框内容而变化。
瑞士万通离子色谱仪800 Dosino进样器说明书--中文

800 Dosino –开始参数标签: 方法▶设备▶ Dosino溶液Select the solution for the Dosino that should be available when the hardware is started with [Start HW]. A check is carried out in the method run to ensure that the correct solution has been put on the dosing device. When the method is started, the working life and GLP test interval are checked for the selected solution.选择未定义 | Solutions from the solution table默认值未定义未定义The solution is not checked.Solutions from the solution tableOnly "intelligent" solutions, i.e. solutions that are assigned to an 807 Dosing unit, can be selected.ConnectorShows the main device and the MSB connector which the 800 Dosino is on.800 Dosino –命令Overview of the time program commands available for the 800 Dosino: 加液对话窗口:方法▶时间程序▶编辑▶‘设备’–加液The device-dependent time program command Dosing (command with feedback) doses the specified volume via the defined port. There is no automatic filling beforehand or afterwards.参数PortPort via which dosing takes place. Formula input possible.1 (4)范围默认值 1V olumeVolume to be transported. Formula input possible.范围0.0000 ... 99999.9000 mL默认值 1.0000 mLDosing rateSpeed at which discharge takes place. The 最大值 rate depends on the cylinder volume of the buret used. Formula input possible.Cylinder volume 2 mL范围0.01 ... 6.00 mL/min默认值 1.00 mL/min选择最大值Filling rateSpeed at which filling takes place. The 最大值 rate depends on the cylinder volume of the buret used. Formula input possible.Cylinder volume 2 mL范围0.01 ... 6.00 mL/min默认值 1.00 mL/min选择最大值命令时间程序命令的可选注释。
万通离子色谱eco

万通离子色谱eco万通离子色谱仪(Eco型)是一款先进的离子分析仪器,广泛应用于环境监测、食品安全、化工、医药等领域。
以下是对万通离子色谱仪(Eco型)的详细说明,包括其原理、结构、特点、应用等方面的内容。
一、离子色谱原理离子色谱法是一种高效液相色谱法,利用离子交换树脂的固定相和流动相中的离子进行交换,实现对离子的分离和检测。
在离子色谱仪中,样品被注入色谱柱,色谱柱内的固定相(离子交换树脂)与流动相(淋洗液)中的离子发生交换反应。
随着淋洗液的流动,不同离子在固定相上的保留时间不同,从而实现离子的分离。
分离后的离子进入检测器进行检测,得到离子的浓度信息。
二、万通离子色谱仪(Eco型)结构1.输液系统:包括高压泵、淋洗液储液瓶、过滤器等,用于提供稳定的淋洗液流。
2.色谱柱:色谱柱是离子分离的核心部件,通常由离子交换树脂填充而成。
3.检测器:用于检测分离后的离子浓度,常用的检测器有电导检测器、紫外可见检测器等。
4.数据处理系统:用于采集、处理和分析色谱数据,得到离子的浓度、保留时间等信息。
5.控制系统:用于控制仪器的运行,包括输液系统的控制、检测器的控制等。
三、万通离子色谱仪(Eco型)特点1.高灵敏度:采用先进的检测器技术,能够检测到低浓度的离子。
2.高分辨率:色谱柱具有高分离效能,能够实现复杂样品中离子的有效分离。
3.宽线性范围:仪器具有宽线性范围,能够准确测量不同浓度的离子。
4.自动化程度高:仪器具有自动进样、自动淋洗、自动检测等功能,操作简单方便。
5.高稳定性:输液系统和检测系统稳定性好,能够长时间连续运行而不产生漂移。
6.环保节能:采用低功耗设计,降低能源消耗;同时采用环保材料制造,减少对环境的影响。
7.易于维护:仪器设计合理,易于维护和保养,降低使用成本。
四、万通离子色谱仪(Eco型)应用1.环境监测:用于水质、大气、土壤等环境样品中阴阳离子的分析,如氟离子、氯离子、硫酸根离子等。
2.食品安全:用于食品中添加剂、农药残留等有害物质的检测,如亚硝酸盐、硝酸盐等。
离子色谱仪的使用方法说明书

离子色谱仪的使用方法说明书一、产品概述离子色谱仪是一种常用的分析仪器,用于检测和分离溶液中离子和有机物。
它基于离子交换原理,通过色谱柱将样品中的离子分离出来,并通过检测器进行定量分析。
本说明书将详细介绍离子色谱仪的使用方法,包括仪器准备、样品准备、操作步骤等。
二、仪器准备1. 确保离子色谱仪已经连接电源,并处于工作状态。
2. 检查色谱柱和系统的连接情况,确保连接紧密无泄漏。
3. 打开仪器软件,并进行参数设置。
三、样品准备1. 根据待分析样品的特性选择合适的色谱柱和流动相。
2. 准备样品溶液,确保其浓度适宜,同时避免样品中存在影响分析的杂质。
3. 调整样品的pH值,使其适应离子色谱仪的条件。
四、操作步骤1. 进样将准备好的样品注射进离子色谱仪的进样器,控制注射量和流速。
样品在色谱柱中进行分离,根据样品的特性选择合适的分离条件,如温度、流速等。
3. 检测离子色谱仪的检测器会检测样品中的离子浓度或有机物的浓度,根据需要进行定量或定性分析。
4. 数据处理将检测到的数据导出到计算机中,并进行数据处理和分析。
五、注意事项1. 操作前应仔细阅读仪器的操作手册,并按照说明进行操作。
2. 保持实验室的清洁和整齐,避免杂质对分析结果的影响。
3. 定期清洗和维护离子色谱仪,以保证其正常运行和准确性。
4. 注意使用化学品时的安全性,避免接触有害物质。
5. 操作完成后及时关闭离子色谱仪,并进行设备的清理和维护工作。
六、故障排除在使用离子色谱仪时,可能会遇到一些故障情况,如峰裂、基线漂移等。
对于常见的故障情况,可以通过仪器手册或向仪器供应商咨询来解决。
离子色谱仪是一种常用的分析仪器,本说明书详细介绍了离子色谱仪的使用方法,包括仪器准备、样品准备、操作步骤等。
在使用离子色谱仪时,应注意操作规范和安全性,同时定期进行维护和保养,以保证仪器的准确性和可靠性。
如有任何疑问或故障情况,请及时联系仪器供应商。
离子色谱自动进样器说明书

离子色谱自动进样器说明书离子色谱自动进样器是一种用于离子色谱分析的仪器,它的作用是将样品自动引入离子色谱仪中进行分析。
这种仪器通常包括样品处理、进样、混合和输送等功能模块,能够实现自动化、高通量的样品分析。
接下来我会从不同角度对离子色谱自动进样器进行说明。
首先,让我们从技术角度来看。
离子色谱自动进样器通常由进样阀、进样泵、样品处理模块、混合器、进样环路等部件组成。
进样阀用于控制样品的进出,进样泵则用于输送样品。
样品处理模块可以对样品进行预处理,例如稀释、溶解等。
混合器用于混合样品和流动相,进样环路则用于将样品引入色谱柱进行分离。
整个系统通过控制软件实现自动化操作,提高了分析的精度和效率。
其次,从应用角度来看。
离子色谱自动进样器广泛应用于环境监测、食品安全、生命科学等领域。
在环境监测中,它可以用于检测水体中的离子物质,如氯离子、硝酸盐等。
在食品安全领域,可以用于检测食品中的添加剂、重金属等有害物质。
在生命科学领域,可以用于分析生物样品中的离子化合物,如氨基酸、有机酸等。
离子色谱自动进样器的高通量、高灵敏度和高分辨率特点,使其成为现代化学分析实验室中不可或缺的仪器之一。
最后,从操作维护角度来看。
离子色谱自动进样器在使用过程中需要严格遵守操作规程,定期进行维护保养。
操作人员需要掌握仪器的使用方法,了解各部件的功能和操作原理,合理设置分析参数,确保分析结果的准确性和可靠性。
同时,定期对进样器进行清洗、校准和维护,保持仪器的稳定性和可靠性,延长其使用寿命。
综上所述,离子色谱自动进样器是一种在化学分析领域广泛应用的高端仪器,具有自动化、高通量、高灵敏度和高分辨率等特点。
它在环境监测、食品安全、生命科学等领域发挥着重要作用,需要严格遵守操作规程和定期进行维护保养,以保证分析结果的准确性和可靠性。
瑞士万通离子色谱仪标准操作规程

瑞士万通离子色谱仪标准操作规程第一篇:瑞士万通离子色谱仪标准操作规程瑞士万通离子色谱仪标准操作规程1、目的确保使用仪器的规范性,避免操作不当造成仪器的损坏,规定此操作规程。
2、范围适用于瑞士万通离子色谱仪的使用。
3、职责检验员严格按照标准操作规程进行操作使用和维护,并做好使用记录。
4、操作规程 4.1实验准备实验所用液体及样品必须经过0.45滤膜过滤后使用。
4.2开机依次打开控制电脑、881Compact IC pro、863 Compact autosampler、打印机电源。
打开色谱仪操作软件。
4.3淋洗液配制“工作平台”界面—“平衡”—选“稀释淋洗液”程序—“单次测量”—“值1”处修改配制体积(40的倍数)—“开始”。
4.4平衡机器“工作平台”界面—“平衡”—选取“平衡程序”程序—“启动硬件”,仪器开始平衡。
若压力过高,在“方法”界面—打开“平衡程序”程序—“泵”处设定“流速”,由0.3ml/min开始,0.1ml/min递增至0.8ml/min,平衡时间约1小时。
4.3编辑“测量序列”在“工作平台”界面—“测量序列”—双击每个样品行编辑检测方法、名称、样品类型等。
选中“样品执行结束后停止硬件”在样品检测后自动关机。
4.4分析测定“测量序列”编辑完成后,点击“开始”按钮,开始测量,在测定过程中,可对批处理表中未测定的信息进行编辑。
4.5数据处理在“数据库”界面—选中标准溶液及样品—点击右键—“再处理”进入数据处理,选择相应的处理方法进行数据处理。
4.6报告在“数据库”界面—选中样品数据—点击“文件”—“打印”—“报告”—选择报告类型、输出目标等。
4.7关机退出操作软件,依次关闭881Compact IC pro、863 Compact autosampler、控制电脑、打印机电源。
第二篇:万通861型离子色谱仪简要操作手册_cn万通861型离子色谱仪简要操作手册(中文)阴离子系统一、打开系统:双击桌面离子色谱软件图标IC Net 2.3,输入用户名称和密码。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
800 Dosino - GeneralThe 800 Dosino is a flexible dosing drive which, as an MSB device, can be used with a host of Metrohm main devices. Together with the intelligent 807 Dosing unit, it is well suited for both simple dosing and for automation and liquid handling tasks, such as sample transfer or pipetting.NoteMagIC Net only supports the use of intelligent 807 Dosing units! Configuration MSB DeviceAn MSB device is not entered in the device table. In the configuration it is only listed under the MSB connections of the main device to which it is connected (e.g. 850 Professional IC or 858 Professional Sample Processor).800 Dosino - MethodAn 800 Dosino (as is the case with all MSB devices) cannot be added separately to a method. It is added to the list of devices by adding the main device to which it is connected to the method.If the method is created without connected devices, the MSB device can be added separately. In this case, the MSB connector on the main device must be entered manually.In the device group, the 800 Dosino behaves like a stand-alone device. It can be selected and displayed graphically in the upper area of the device window.800 Dosino - Start parametersTab: Method ▶ Devices ▶ DosinoSolutionSelect the solution for the Dosino that should be available when the hardware is started with [Start HW]. A check is carried out in the method run to ensure that the correct solution has been put on the dosing device. When the method is started, the working life and GLP test interval are checked for the selected solution.Selection not defined | Solutions from the solution tableDefault value not definednot definedThe solution is not checked.Solutions from the solution tableOnly "intelligent" solutions, i.e. solutions that are assigned to an 807 Dosing unit, can be selected.ConnectorShows the main device and the MSB connector which the 800 Dosino is on.800 Dosino - CommandsOverview of the time program commands available for the 800 Dosino:DosingDialog window: Method ▶Time program ▶Edit ▶'Device' - DosingThe device-dependent time program command Dosing (command with feedback) doses the specified volume via the defined port. There is no automatic filling beforehand or afterwards.ParametersPortPort via which dosing takes place. Formula input possible.Range 1 (4)Default value 1V olumeVolume to be transported. Formula input possible.Range0.0000 ... 99999.9000 mLDefault value 1.0000 mLDosing rateSpeed at which discharge takes place. The maximum rate depends on the cylinder volume of the buret used. Formula input possible.Cylinder volume 2 mLRange0.01 ... 6.00 mL/minDefault value 1.00 mL/minSelection maximumCylinder volume 5 mLRange0.01 ... 16.00 mL/minDefault value 1.00 mL/minSelection maximumCylinder volume 10 mLRange0.01 ... 33.00 mL/minDefault value 1.00 mL/minSelection maximumCylinder volume 20 mLRange0.01 ... 66.00 mL/minDefault value 1.00 mL/minSelection maximumCylinder volume 50 mLRange0.01 ... 166.00 mL/minDefault value 1.00 mL/minSelection maximumFilling rateSpeed at which filling takes place. The maximum rate depends on the cylinder volume of the buret used. Formula input possible.Cylinder volume 2 mLRange0.01 ... 6.00 mL/minDefault value 1.00 mL/minSelection maximumCylinder volume 5 mLRange0.01 ... 16.00 mL/minDefault value 1.00 mL/minSelection maximumCylinder volume 10 mLRange0.01 ... 33.00 mL/minDefault value 1.00 mL/minSelection maximumCylinder volume 20 mLRange0.01 ... 66.00 mL/minDefault value 1.00 mL/minSelection maximumCylinder volume 50 mLRange0.01 ... 166.00 mL/minDefault value 1.00 mL/minSelection maximumCommentOptional comment on the time program command.Input64 charactersGenerated variablesThe following type 'mand number.Variable name' variables are generated by the command:AspirateDialog window: Method ▶Time program ▶Edit ▶'Device' - AspirateThe device-dependent time program command Aspirate (command with feedback) draws in the specified volume via the defined port. As with the command Dosing, the cylinder is not filled automatically beforehand or afterwards. It should be possible to achieve the volume to be aspirated with a single piston stroke.ParametersPortPort via which aspiration takes place. Formula input possible.Range 1 (4)Default value 1V olumeVolume to be transported. Formula input possible.Range0.0000 ... 50.0000 mLDefault value 1.0000 mLRateThe maximum rate depends on the cylinder volume of the buret used. Formula input possible.Cylinder volume 2 mLRange0.01 ... 6.00 mL/minSelection maximumDefault value maximumCylinder volume 5 mLRange0.01 ... 16.00 mL/minSelection maximumDefault value maximumCylinder volume 10 mLRange0.01 ... 33.00 mL/minSelection maximumDefault value maximumCylinder volume 20 mLRange0.01 ... 66.00 mL/minSelection maximumDefault value maximumCylinder volume 50 mLRange0.01 ... 166.00 mL/minSelection maximumDefault value maximumCommentOptional comment on the time program command.Input64 charactersGenerated variablesThe following type 'mand number.Variable name' variables are generated by the command:FillDialog window: Method ▶Time program ▶Edit ▶'Device' - FillThe device-dependent time program command Fill (command with feedback) fills the cylinder via the specified port. The valve disc stops on the selected port.ParametersPortPort via which filling takes place. Formula input possible.Range 1 (4)Default value 2RateThe maximum rate depends on the cylinder volume of the buret used. Formula input possible.Cylinder volume 2 mLRange0.01 ... 6.00 mL/minSelection maximumDefault value maximumCylinder volume 5 mLRange0.01 ... 16.00 mL/minSelection maximumDefault value maximumCylinder volume 10 mLRange0.01 ... 33.00 mL/minSelection maximumDefault value maximumCylinder volume 20 mLRange0.01 ... 66.00 mL/minSelection maximumDefault value maximumCylinder volume 50 mLRange0.01 ... 166.00 mL/minSelection maximumDefault value maximumCommentOptional comment on the time program command.Input64 charactersEject to end volumeDialog window: Method ▶Time program ▶Edit ▶'Device' - Eject to end volumeThe device-dependent time program command Eject to end volume (command with feedback) ejects the entire contents of the cylinder via the specified port. In contrast to the command Eject to stop, the piston travels to the maximum volume mark i.e. until it has performed 10,000 pulses. This command should be used for pipetting functions for emptying the cylinder.ParametersPortPort via which ejection takes place. Formula input possible.Range 1 (4)Default value 4RateThe maximum rate depends on the cylinder volume of the buret used. Formula input possible.Cylinder volume 2 mLRange0.01 ... 6.00 mL/minSelection maximumDefault value maximumCylinder volume 5 mLRange0.01 ... 16.00 mL/minSelection maximumDefault value maximumCylinder volume 10 mLRange0.01 ... 33.00 mL/minSelection maximumDefault value maximumCylinder volume 20 mLRange0.01 ... 66.00 mL/minSelection maximumDefault value maximumCylinder volume 50 mLRange0.01 ... 166.00 mL/minSelection maximumDefault value maximumCommentOptional comment on the time program command.Input64 charactersEject to stopDialog window: Method ▶Time program ▶Edit ▶'Device' - Eject to stopThe device-dependent time program command Eject to stop (command with feedback) ejects the entire contents of the cylinder via the specified port. The piston is lowered to the stop point, i.e. past the maximum volume mark.NoteThis function should only be carried out to eject any air bubbles present.CautionThe command aspirate does not function directly after Eject to stop.If aspiration is to take place after Eject to stop, then Eject to end volume must first be carried out. In this command, the port via which aspiration is to take place must already be selected.ParametersPortPort via which ejection takes place. Formula input possible.Range 1 (4)Default value 4RateThe maximum rate depends on the cylinder volume of the buret used. Formula input possible.Cylinder volume 2 mLRange0.01 ... 6.00 mL/minSelection maximumDefault value maximumCylinder volume 5 mLRange0.01 ... 16.00 mL/minSelection maximumDefault value maximumCylinder volume 10 mLRange0.01 ... 33.00 mL/minSelection maximumDefault value maximumCylinder volume 20 mLRange0.01 ... 66.00 mL/minSelection maximumDefault value maximumCylinder volume 50 mLRange0.01 ... 166.00 mL/minSelection maximumDefault value maximumCommentOptional comment on the time program command.Input64 charactersExchange positionDialog window: Method ▶Time program ▶Edit ▶'Device' - Exchange positionWith the device-dependent time program command Exchange position (command with feedback) the cylinder is first filled via the port specified. The valve disc is then turned to Port 2 and the dosing unit can be removed from the dosing drive.ParametersFill portPort via which filling takes place. Formula input possible.Range 1 (4)Default value 2RateThe maximum rate depends on the cylinder volume of the buret used. Formula input possible.Cylinder volume 2 mLRange0.01 ... 6.00 mL/minSelection maximumDefault value maximumCylinder volume 5 mLRange0.01 ... 16.00 mL/minSelection maximumDefault value maximumCylinder volume 10 mLRange0.01 ... 33.00 mL/minSelection maximumDefault value maximumCylinder volume 20 mLRange0.01 ... 66.00 mL/minSelection maximumDefault value maximumCylinder volume 50 mLRange0.01 ... 166.00 mL/minSelection maximumDefault value maximumCommentOptional comment on the time program command.Input64 charactersChange portDialog window: Method ▶Time program ▶Edit ▶'Device' - Change portThe device-dependent time program command Change port (command with feedback) results only in one rotation of the valve to the given port and not in any piston movement.ParametersPortPort to which the valve is rotated. Formula input possible.Range 1 (4)Default value 2CommentOptional comment on the time program command.Input64 charactersCompensateDialog window: Method ▶Time program ▶Edit ▶'Device' - CompensateBecause of the fact that the dosing units are interchangeable, the coupling of the Dosino piston rod (spindle) exhibits a low mechanical tolerance that can be noticed when the piston changes its direction of movement. This tolerance can be compensated for with the device-dependent time program command Compensate (command with feedback). A short piston movement is first made in the same direction as the previous movement, which is then followed by a piston movement in the reverse direction.ParametersPortPort via which the piston motion runs. Formula input possible.Range 1 (4)Default value 4CommentOptional comment on the time program command.Input64 charactersPrepareDialog window: Method ▶Time program ▶Edit ▶'Device' - PrepareThe device-dependent time program command Prepare (command with feedback) is used to prepare a dosing unit.The cylinder and all the tubing of a dosing unit are rinsed in an extensive cleaning sequence. The parameters required for this process are stored in the configuration of the solution.CommentOptional comment on the time program command.Input64 charactersEmptyDialog window: Method ▶Time program ▶Edit ▶'Device' - EmptyThe device-dependent time program command Empty (command with feedback) is used to empty the cylinder and the tubing of a dosing unit.The cylinder and all the tubing of a dosing unit are emptied in an extensive sequence. The parameters required for this process are stored in the configuration of the solution.CommentOptional comment on the time program command.Input64 charactersReleaseDialog window: Method ▶Time program ▶Edit ▶'Device' - 'Module' - ReleaseThe device-dependent time program command Release (command without feedback) releases the module/device for use by other methods running at the same time. It removes the reservation made by the current method.TimeTime at which the command is to be executed.Range0.00 ... 10000.00 minIncrement0.01 minDefault value0.00 minCommentOptional comment on the time program command.Input0 ... 64 characters800 Dosino - Manual ControlTab: Manual ▶Manual Control - 'Device name' ▶'Dosino'CommandSelection of the Dosino command that is to be triggered manually.Selection Dosing | Aspirate | Fill | Prepare | EmptyDefault value DosingDosingDoses the specified volume via the defined port. There is no automatic filling beforehand or afterwards.AspirateAspirates the specified volume via the defined port. There is no automatic filling beforehand or afterwards.FillThe cylinder is filled in a fixed sequence. The parameters required for this process are stored in the configuration of the solution.PrepareThe cylinder and all the tubing of a dosing unit are rinsed in an extensive cleaning sequence. The parameters required for this process are stored in the configuration of the solution.EmptyThe cylinder and all the tubing of a dosing unit are emptied in an extensive sequence. The parameters required for this process are stored in the configuration of the solution.SolutionDisplays the solution assigned to the Dosino.VolumeCurrent valueDisplays the current dosed volume.InputEnter the volume that is to be dosed / moved.Range0.0000 ... 99999.9000 (Exception: with command "Aspirate" 50.0000) mL Default value 1.0000 mLPortCurrent valueShows the current port.InputSelection of a port for the action selected in the parameter Command.Range 1 (4)Default value 1Dosing rateInputEnter dosing rate. The maximum rate depends on the cylinder volume of the buret used. Formula input possible.Cylinder volume 2 mLRange0.01 ... 6.00 mL/minSelection maximumDefault value maximumCylinder volume 5 mLRange0.01 ... 16.00 mL/minSelection maximumDefault value maximumCylinder volume 10 mLRange0.01 ... 33.00 mL/minSelection maximumDefault value maximumCylinder volume 20 mLRange0.01 ... 66.00 mL/minSelection maximumDefault value maximumCylinder volume 50 mLRange0.01 ... 166.00 mL/minSelection maximumDefault value maximumFilling rateInputEnter filling rate. The maximum rate depends on the cylinder volume of the buret used. Formula input possible.Cylinder volume 2 mLRange0.01 ... 6.00 mL/minSelection maximumDefault value maximumCylinder volume 5 mL Range0.01 ... 16.00 mL/minSelection maximumDefault value maximumCylinder volume 10 mL Range0.01 ... 33.00 mL/minSelection maximumDefault value maximumCylinder volume 20 mL Range0.01 ... 66.00 mL/minSelection maximumDefault value maximumCylinder volume 50 mL Range0.01 ... 166.00 mL/minSelection maximumDefault value maximum[Start]Start Dosino command.[Stop]Stop Dosino command.。