8.1 CMW710-R0106P02 版本解决问题列表 ···························································································· 10 8.2 CMW710-R0106 版本解决问题列表··································································································· 11 8.3 CMW710-R0105P12 版本解决问题列表 ···························································································· 12 8.4 CMW710-R0105P06 版本解决问题列表 ···························································································· 13 8.5 CMW710-R0105 版本解决问题列表··································································································· 13 8.6 CMW710-E0104 版本解决问题列表··································································································· 14 8.7 CMW710-E0102 版本解决问题列表··································································································· 14 8.8 CMW710-E0006P02 版本解决问题列表 ···························································································· 14 9 相关资料 ············································································································································· 14 9.1 相关资料清单······································································································································ 14 9.2 资料获取方式······································································································································ 15 10 技术支持 ··········································································································································· 15 附录 A 本版本支持的软、硬件特性列表································································································· 16 A.1 版本硬件特性 ····································································································································· 16 A.2 版本软件特性 ····································································································································· 23

C升级步骤

C升级步骤

C300升级步骤1.升级准备工具准备笔记本电脑(带串口或USB转串口),十字和一字螺丝刀,C300的串口线,网线,CPLD烧结专用线和烧结软件(防止因 boot升级失误需要烧录 boot芯片)硬件准备有条件的话准备主控板和PON板备用板各一块。

软件准备、数据备份及升级前运行状态检查和记录从C300firmware版本(CPLD版本可以在线升级)。

1 •准备好所有线卡的软硬件版本;2. 保存配置数据文件 startrun.dat到服务器,以备回退到升级前的版本;ZXAN#uploadcfgstartrun.dat//把配置文件从flash拷到FTP服务器的FTP目录下(前置条件:配置好外部ftp服务器及网元的ftp服务器配置);2.升级步骤1.1.1.环境搭建CLI方式升级版本,需要 FTPServer、待升级版本OLT设备和OLT设备操作台(可以控制 OLT设备的计算机,串口方式、Telnet方式控制均可)。

FTPServer和待升级版本 OLT设备要求接入同一网络。

FTPServer 和OLT设备操作台的运行位置没有特定要求。

图CLI 方式升级版本运行FTPServer运行FTPServer,配置FTP用户、密码,将版本文件放在指定路径下。

配置网元1、 C300 系统启动完成后,可以在特权模式下使用showinterfacemng1 显示当前带外 MAC, IP , boot 环境下 ftp 的服务器 IP , username,password 等信息。

ZXAN#showinterfacemng1mngrunninginformationipaddress:mask:boot-server:boot-username:gponboot-password:******config-filename:startrun.datimgfile-location:localinband-mac:outband-mac:注: Ipaddress 参数表示网元的带外 IP 。

升级过程与操作步骤

升级过程与操作步骤

升级的主要步骤如下:1.配置新采购的2台华为S6720S-SI 交换机,并与S5720S 进行连接。

2.将新配置的服务器连接到网络,并加入现有vSAN。

3.依次将原来的每台主机进入维护模式,重新分配vSAN 流量上行链路、删除vvSwitch1、重新配置vSwitch0,配置完成后退出维护模式。

4.对vSAN 磁盘执行主动平衡操作。

5.虚拟机默认的虚拟网卡为Intel E1000,这是一块千兆网卡,要将虚拟机网络升级到万兆,需要修改虚拟机的网卡为VMXNET3,删除原来的Intel E1000虚拟网卡。

添加VMXNET3虚拟网卡、删除E1000虚拟网卡后,进入虚拟机设置,为新添加的网卡设置IP 地址、子网掩码、升级过程与操作步骤网关、DNS。

将2台S6720S-SI 交换机配置为堆叠首先配置2台S6720S-SI 交换机,然后将这2台万兆交换机与原来的2台千兆交换机级联。

1.将新采购的2台华为S6720S-SI 交换机配置为堆叠,每台交换机使用2个40G 端口。

将每台交换机的业务口40GE0/0/1、40GE0/0/2配置为物理成员端口,并加入到相应的逻辑堆叠端口。

下面是第一台交换机的配置命令(设置堆叠优先级为200)。

system-view sysname SwitchAinterface stack-port0/1p o r t i n t e r f a c e 40GE0/0/1 enabley quitinterface stack-port0/2p o r t i n t e r f a c e 40GE0/0/2 enabley quitstack slot 0 priority 200上文命令中的Y 是确认命令。

设置完成后保存配置。

另一台交换机的配置与此相同,只是设置交换机的名称为SwitchB,设置堆叠优先级为100。

其他配置相同。

配置完成后保存退出。

2.然后将两台交换机下电,使用QSFP-40G 的堆叠线将两台交换机连接起来,在连接的时候,第一台交换机的40GE0/0/1的端口连接第二台交换机的40GE0/0/2端口,第一台交换机的40GE0/0/2端口连接第二台原vSwitch1虚拟交换机同名的端口组。

AP升级步骤

AP升级步骤

AP升级步骤一、在交换机升级:1.配置DHCP软件。

打开软件,配置“高级→配置→高级→使用一下指定的IP范围”,为DHCP服务器配置一个地址池。

如;2.配置扫描软件。

打开软件,在扫描IP栏里,输入你自己所配置的IP地址池:,点击红色按钮或者按回车键进行扫描。

查看扫描结果,如果IP地址前面显示为蓝色的,是可以连接的AP,对其进行升级。

如果IP地址前面显示为红色的,是不可以连接的AP,不用对其进行升级:;3.配置登陆软件。

打开软件,在弹出的快速连接对话框里,“主机名”填你需要升级AP 的IP地址,“用户名”填写账号“root”,连接成功后在填写密码“public”;4.AP版本。

现在针对4.1.1版本有两个:3C和3S。

通过查看AP的硬件信息(show hardware),中MEM为128的是老的硬件平台,用3S,为64的就是新的硬件平台,用3C。

5.AP升级。

进入AP后,使用“enable”命令进入特权模式,在使用“show version”查看AP版本,如果是老的版本就要升级AP。

升级时首先打开软件,把升级包拖到网络文件服务器的地址栏里并复制该地址,再在AP的特权模式下输入以下命令:u u 复制的url地址r.例如:upgrade url http://192.168.0.5/AzOS_v4.1.1_3S.img reboot就可以升级了。

二、在AP上升级:1.把两头是USB插头的控制线一头插AP上,一头插电脑上。

2.进入AP。

打开软件,在弹出的快速连接对话框里,协议选Serial,端口选AP在电脑上显示的端口。

波特率选115200,数据位8,奇偶效验None,停止位1.,然后连接AP。

3.在AP使用如下命令:MSR1000> enMSR1000# conf tMSR1000(config)# int g 0MSR1000(config-eth)#ip add 192.168.0.2/24MSR1000(config-eth)#endMSR1000#up u http://192.168.0.5/AzOS_v4.1.1_3S.img r三、如果AP升级完成,AP还没上线。

锐捷交换机从10.x升级到最新版本升级指南

锐捷交换机从10.x升级到最新版本升级指南

锐捷交换机从 10.x 升级到 10.x 升级指南
任意填入一个区号后点击“确定” ,出现以下信息。
再次点击“确定”便打开了超级终端。
锐捷交换机从 10.x 升级到 10.x 升级指南
名称任意填写,然后点击“确定” 。
在“连接时使用”选择当前配置线连接的 COM 口,然后点击“确定” 。
锐捷交换机从 10.x 升级到 10.x 升级指南

都是福建星网锐捷网络有限公司的
锐捷交换机从 10.x 升级到 10.x 升级指南
目录 正常模式下的升级(主程序下升级)................................................................................ 5 1.1 设备连接 ........................................................................................................ 5 1.2 超级终端设置 ................................................................................................. 5 1.3 1.4 1.5 升级前的准备 ................................................................................................. 9 备份配置文件(可选) ................................................................................... 9 配置 PC 及交换机的 IP................................................................................... 11

MCU升级指导书

MCU升级指导书

1. 升级指导书1.1. 升级文件清单mcu-boot.bin :MCU最小系统的升级软件;mcu-soft.exe :MCU主机软件的压缩包。

解压后包括:mcu-soft.bin(MCU升级软件),IVR目录(包含了IVR提示语音的升级文件);1.2. 升级部分1.2.1.1.当前运行版本信息确认由于存在C01和C02、R002、R003的软件版本,因此升级前明确:1、C01的软件版本号是Release 1.xx.x,C02的软件版本号是2.xx.x,R002的软件版本号是3.xx.x,R3C01的软件版本号是5.xx.x;2、后续版本号更改了,R3C02为3.2.x.x,R3C03为 3.3.x.x,R5为5.1.x.x3、查看当前MCU的版本号(A.xx.x),比较需要升级的版本号(B.xx.x),如果A和B不同,则说明是不同R版本之间的升级,需参软件不同R版本之间的升级注意事项。

注意:R002(3.xx.x)及以后的版本之间不存在限制,可以相互升降级4、C02及以后版本可以通过命令行升级mcu-boot.bin,即升级最小系统,尽量保持小系统与主机版本配套,发布版本要求小系统与主机板本兼容。

5、MCU V100产品资源以及功能约束是通过license控制,license文件需要MCU的ESN匹配,否则系统应用受限;如果系统需要支持语音提示功能,需要配套的IVR文件;license与IVR文件通过导入方式加载到MCU,主机软件通过升级方式,加载到MCU。

1.2.1.2.升级前的数据备份版本升级前建议先备份配置数据。

通过在“upgrade”模式下键入“export”命令,选择“mcu-device-config.xml”,可导出MCU的配置文件到FTP服务器上备份;注意:请打开FTP服务器上的写权限;软件在C01、C02、R002、R003版本之间互相升级时,请一定先备份配置数据。

1.2.1.3.软件加载准备MCU的软件升级,需要在一台电脑上安装FTP服务器,之后MCU通过命令行或网管从FTP服务器上下载升级软件,并保存到MCU的Flash中,完成升级过程。

CISCO路由器的IOS升级

IOS升级方法一在对能够正常启动的CISCO路由器的IOS进行升级时,比较简单。

具体步骤如下:1、寻找一种TFTP服务器软件(有CISCO公司的TFTPServer或3COM公司的3Cserver等,在升级较大IOS映象文件时,建议用3Cserver),安装在一台计算机上,将要升级的IOS映象文件拷贝到相关的目录中(例:D:\),并运行TFTP服务器软件,通过菜单设置Root目录为拷贝IOS映象文件所在目录(如D:\)。

假设该计算机的IP地址为10.32.10.1;2、连接路由器的console口和PC机的COM1,使用PC的终极终端软件访问路由器,将路由器的地址设为10.32.10.32(和计算机的IP地址同网段即可)。

建议在进行IOS升级前将原有IOS文件备份下来,防止待升级的IOS文件存在问题不可用;QUOTE:Router# dir flash: (查看目前IOS映象文件名,也可用Router#Show version)Directory of flash:/1 -rw- 5998292 C2600-I-MZ.122-11.BIN8388608 bytes total (2390252 bytes free)Router#copy flash tftp (备份IOS文件)Source filename []?c2600-i-mz.122-11.binAddress or name of remote host []? 10.32.10.1 (TFTP服务器地址)Destination filename [c2600-i-mz.122-11.bin]?!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!…!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!5998292 bytes copied in 324.071 secs (18509 bytes/sec)Router#3、对路由器进行IOS升级;QUOTE:Router#copy tftp flashAddress or name of remote host []? 10.32.10.1 (TFTP服务器地址)Source filename []? c2600-i-mz.122-11.bin (需升级的新IOS映象文件名)Destination filename [c2600-i-mz.122-11.bin]?Do you want to over write? [confirm]Accessing tftp://10.32.10.1/c2600-i-mz.122-11.bin...Erase flash: before copying? [confirm]Erasing the flash filesystem will remove all files! Continue? [confirm]Erasing device... eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee ...erasedeeErase of flash: completeLoading c2600-i-mz.122-11.bin from 10.32.10.1 (via Ethernet0/0): !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!…!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!![OK - 5998292 bytes]Verifying checksum... OK (0xA0C0)5998292 bytes copied in 318.282 secs (18846 bytes/sec)Router#++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++IOS升级方法二由于升级失败后或路由器的config-register寄存器值为0x2101时,开启路由器时、或在开启(某些型号)Cisco路由器的电源开关后30秒内按下Ctrl+break键,中断路由器的正常启动,路由器都会进入rom监视模式,即Router(boot)>,在这种情形下,对路由器的IOS 进行升级,也比较简单。

H3C交换机IOS版本升级过程实录

H3C交换机IOS版本升级过程实录H3C交换机IOS版本升级过程实录一、确认当前IOS软件版本及可用存储空间(要求可用空间为IOS 文件的2倍,否则无法升级成功)dis versionH3C Comware Software, Version 7.1.045, Release 3106Copyright (c) 2004-2014 Hangzhou H3C Tech. Co., Ltd. All rights reserved.H3C S5130-52S-PWR-EI uptime is 0 weeks, 3 days, 21 hours, 39 minutesLast reboot reason : Cold rebootBoot image: flash:/s5130ei_e-cmw710-boot-r3106.binBoot image version: 7.1.045, Release 3106Compiled Jul 31 2014 08:36:45System image: flash:/s5130ei_e-cmw710-system-r3106.bin System image version: 7.1.045, Release 3106Compiled Jul 31 2014 08:36:45Slot 1:Uptime is 0 weeks,3 days,21 hours,39 minutesH3C S5130-52S-PWR-EI with 1 ProcessorBOARD TYPE: H3C-S5130-52S-PWR-EIDRAM: 992M bytesFLASH: 512M bytesPCB 1 Version: VER.BBootrom Version: 109CPLD 1 Version: 002Release Version: H3C S5130-52S-PWR-EI-3106Patch Version : NoneReboot Cause : ColdReboot[SubSlot 0] 48GE+4SFP Plusdir flash:/Directory of flash:0 drw- - Jan 01 2013 08:00:44 diagfile1 -rw- 1502 Jan 16 2013 07:20:59 ifindex.dat2 drw- - Jan 01 2013 08:00:48 license3 drw- - Jan 01 2013 08:54:35 logfile4 -rw- 8849408 Aug 09 2008 04:00:00 s5130ei_e-cmw710-boot-r3106.bin5 -rw- 56037376 Aug 09 2008 04:00:00 s5130ei_e-cmw710-system-r3106.bin6 drw- - Jan 01 2013 08:00:44 seclog7 -rw- 17732 Jan 16 2013 07:21:00 startup.cfg8 -rw- 180840 Jan 16 2013 07:21:00 startup.mdb9 drw- - Jan 01 2013 08:00:52 versionInfo524288 KB total (449168 KB free)二、通过3CDaemon软件下载IOS文件,在网的H3C交换机可以直接从接入网络的笔记本(用3CDaemon软件配置为TFTP服务器)下载tftp 1.1.1.2 get S5130EI_E-CMW710-R3109P09.ipePress CTRL+C to abort.% Total % Received % Xferd Average Speed Time Time Time CurrentDload Upload Total Spent Left Speed100 66.4M 100 66.4M 0 0 128k 0 0:08:51 0:08:51 --:--:-- 206k三、确认交换机下载文件成功及文件位置dir flash:/Directory of flash:0 -rw- 69705728 Jan 01 2013 00:54:36 S5130EI_E-CMW710-R3109P09.ipe1 drw- - Jan 01 2013 00:00:44 diagfile2 drw- - Jan 01 2013 00:00:48 license3 drw- - Jan 01 2013 00:00:44 logfile4 -rw- 8849408 Aug 08 2008 20:00:00 s5130ei_e-cmw710-boot-r3106.bin5 -rw- 56037376 Aug 08 2008 20:00:00 s5130ei_e-cmw710-system-r3106.bin6 drw- - Jan 01 2013 00:00:44 seclog7 drw- - Jan 01 2013 00:00:53 versionInfo524288 KB total (391400 KB free)四、升级启动包,指定交换机下次启动软件包为newfilename.ipeboot-loader file flash:/S5130EI_E-CMW710-R3109P09.ipe slot ?<1> Slot numberboot-loader file flash:/S5130EI_E-CMW710-R3109P09.ipe slot 1 ?backup Specify the packages as the backup startup software imagesmain Specify the packages as the main startup software imagesboot-loader file flash:/S5130EI_E-CMW710-R3109P09.ipe slot 1 main Verifying the IPE file and the images.......Done.H3C S5130-52S-PWR-EI images in IPE:s5130ei_e-cmw710-boot-r3109p09.bins5130ei_e-cmw710-system-r3109p09.binThis command will set the main startup software images. Continue? [Y/N]:yDo you want to overwrite files without prompt? [Y/N]:yAdd images to slot 1.Decompressing file s5130ei_e-cmw710-boot-r3109p09.bin to flash:/s5130ei_e-cmw710-boot-r3109p09.bin........Done.Decompressing file s5130ei_e-cmw710-system-r3109p09.bin to flash:/s5130ei_e-cmw710-system-r3109p09.bin............................................Done.The images that have passed all examinations will be used as the main startup software images at the next reboot on slot 1.五、重启交换机rebootStart to check configuration with next startup configuration file, please wait.........DONE! Current configuration may be lost after the reboot, save current configuration? [Y/N]:yPlease input the file name(*.cfg)[flash:/startup.cfg](To leave the existing filename unchanged, press the enter key):Validating file. Please wait...Saved the current configuration to mainboard device successfully.This command will reboot the device. Continue? [Y/N]:yNow rebooting, please wait...以下记录为Console线接交换机看到的交换机重启记录,如果是网络升级,则重启过程将不会看到以下启动信息,直到启动写成才能登陆。

华为5G CPE Pro H112 370 本地升级与在线升级指导

华为5G CPE Pro H112-370 本地升级与在线升级指导
通过WebUI升级步骤:
1.设备上电后,参见设备底部标识的IP地址,打开浏览器输入该IP(默认为
192.168.8.1),可以打开设备WebUI管理页面。

(首次登陆默认密码为admin) 2.如下图所示,进入升级管理页面,按照所示步骤选择升级包文件进行升级。

3.升级成功后,设备重启上电,WebUI显示成功信息如下:
4.确认升级成功后版本信息
1在线升级
1.进入升级管理页面,点击[检查更新] ,检测是否存在新版本。

如果存在新版本,UI上
显示新版本的changelog信息和版本信息。

2. 点击【更新】按钮,下载新版本并升级,下载进度参见右方百分比。

3.下载完成后,自动进入安装。

4.安装成功后,重启上电,UI上显示成功信息.。

LTE更换主控板槽位指导书V

LTE更换主控板槽位指导书
1、备份网元数据
网管上选择“软件管理 > 网元文件 > 网元备份”(应用风格)或“维护 > 备份管理 > 网元备份”。

弹出“网元备份”窗口。

在“网元备份”界面的左边面板的导航树上面中,选择“eNodeB”,然后在导航树中,选择要进行数据备份的eNodeB网元。

在弹出对话框中确认上传备份文件到网管
下载网元备份文件到本地
2、将网元备份导入离线CME
3、增加7槽位主控板
4、增加基站7槽位设备IP地址
删除6槽位设备IP地址
5、设置7槽位以太网端口模式
6、修改路由信息
7、修改GPS所接槽位
8、修改SCTPLNK 槽位号
9、删除6槽位主控板
10、校验网元数据
校验出现规则检验失败的话,主要是路由信息(完整性校验有异常不管)删除异常路由其中一条,如下:
11、导出即插即用开站列表并导入网管重新下发配置到网元
12、即插即用→开始→激活基站50%(此时基站重启,马上通知现
场人员移动主控板到7槽位)
13、现场人员移动主控板到7槽位
14、站点正常起来后,需要对GPS进行修改
(1)在更换主控板6槽至7槽位前,需要对LTE主控板信息核实,若LTE主控板为WD23UMPTb3(不支持GPS接口),无法更换,需要进行更换LTE主控板为WD23UMPTb4
(2)站点正常之后需要设置GPS,
LTE侧无GPS,则增加GPS
ADD GPS:SRN=0,SN=7;
设置GPS模式为手动模式
SET CLKMODE:MODE=MANUAL,CLKSRC=GPS,SRCNO=0;。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

IAD132E(T) V1升级到V3版本说明
IAD132E(T)从V3(SIP)升级到V1(MGCP)版本时,有下面几个注意事项:
1.升级版本时需要两个文件:iad_packet 和iad_bios
2.升级顺序必须是先升级iad_bios,再升级iad_packet。

3.特别注意的是:在升级完iad_bios后,必须要重启主机才能进一步升级iad_packet,重启时建议选择掉电复位。

IAD132E(T)从V3升级到V1版本时,升级步骤如下:
1.将机器重启,在出现“Please press CTRL+B to enter bootmenu,other key to boot!”后5秒内同时按下“Ctrl”键和“B”键,进入BIOS 设置菜单。

2.输入bios密码,初始密码为“manager”(或者为空,此时直接回车即可)
3.进入boot menu 菜单模式,输入2,进入加载模式。

如图1所示:
图1
4.选择Download BIOS(前提是已经设置好FTP相关信息,例如FTP的IP地址、用户名和密码等,并且确保ftp已经开启,待加载文件已经放入ftp相应目录),如图2所示:
图2
5. 输入待加载的bios文件名,回车,如图3所示,开始加载bios,直至结束
图3
6.加载完bios文件后,请按“r”键一直回退到上一级菜单,直到回退到系统复位。

当然,建议你选择掉电复位,这么可以避免误操作引起的麻烦。

注意:加载完bios文件后必须要复位,特别在boot menu中不能选择“Boot system from flash”,否则会出现严重后果,必须重新烧写芯片的bios,到时候没有后悔药!
7.重启后,请马上按住ctrl+b,进入bios 菜单,如图4所示,如果没有来得及,你那么可以掉电复位重新开始。

图4 8.输入2进入download submenu,如图5所示:
图5
9.输入2,选择ethernet子菜单,进入图6所示界面:
图6
10.选择1(前提是FTP都已经配置完毕并开启,参考图7,注意,只是参考,请按自己的实际需要来修改FTP相关参数,文件也放置到FTP目录),进入如图8所示界面:
图7
图8
11.如果要加载packet文件(其文件名已经在ftp里设定好了),则选择A,如图9,开始加载:
图9
11. 加载完毕,掉电重启,OK 祝你成功!。