DA型多级清水离心泵说明书

合集下载

D型(原DA1型)卧式多级离心泵(性能全参数)

D型(原DA1型)卧式多级离心泵(性能全参数)

D型(原DA1型)卧式多级离心泵(性能参数)如D(DF、DY、MD)600-60×6D ---- 表示多级清水离心泵DF ---- 表示耐腐多级离心泵DY ---- 表示多级离心油泵MD ---- 表示耐磨多级离心泵600 ---- 表示设计点流量为600m³/h60 ---- 表示设计点单级扬程为60m 6 ---- 表示级数为6级如150D30×7150 ---- 表示泵吸入口直径为150mmD ---- 表示多级离心清水泵30 ---- 表示泵设计点单级扬程为30m 7 ----表示级数为7级(1) D(DF、DY、MD)6-25(2) D(DF、DY、MD)6-50(3) D(DF、DY、MD)12-25(4) D(DF、DY、MD)12-50(5) D(DF、DY、MD)25-30(6) D(DF、DY、MD)25-50(7) 80D(DF、DY、MD)12(8) D(DF、DY、MD)80-30(9) D(DF、DY、MD)46-30(10) D(DF、DY、MD)46-50(11) 100D(DF、DY、MD)16(12) D(DF、DY、MD)85-45? [100 D(DF、DY、MD)45]13) D(DF、DY、MD)85-67(14) D(DF、DY、MD)120-50(15) 125D(DF、DY、MD)25(16) D(DF、DY、MD)155-30? [150D(DF、DY、MD)30](17) D(DF、DY、MD)155-67(18) D(DF、DY、MD)280-43 [200D(DF、DY、MD)43](19) D(DF、DY、MD)280-65 [200D(DF、DY、MD)65](20) D(DF、DY、MD)360-40(21) D(DF、DY、MD)450-60(22) D(DF、DY、MD)500-57(23) D(DF、DY、MD)580-60(24) D(DF、DY、MD)600-60(25) D(DF、DY、MD)720-60。

d型原da型卧式多级离心泵性能参数修订稿

d型原da型卧式多级离心泵性能参数修订稿

d型原d a型卧式多级离心泵性能参数Coca-cola standardization office【ZZ5AB-ZZSYT-ZZ2C-ZZ682T-ZZT18】D型(原DA1型)卧式多级离心泵(性能参数)如D(DF、DY、MD)600-60×6D---- 表示多级清水离心泵DF ---- 表示耐腐多级离心泵DY ---- 表示多级离心油泵MD ---- 表示耐磨多级离心泵600 ---- 表示设计点流量为600m3/h 60 ---- 表示设计点单级扬程为60m 6 ---- 表示级数为6级如150D30×7150---- 表示泵吸入口直径为150mm D---- 表示多级离心清水泵30 ---- 表示泵设计点单级扬程为30m 7 ----表示级数为7级(1) D(DF、DY、MD)6-25(2) D(DF、DY、MD)6-50(3) D(DF、DY、MD)12-25(4) D(DF、DY、MD)12-50(5) D(DF、DY、MD)25-30(6) D(DF、DY、MD)25-50(7) 80D(DF、DY、MD)12(8) D(DF、DY、MD)80-30(9) D(DF、DY、MD)46-30(10) D(DF、DY、MD)46-50(11) 100D(DF、DY、MD)16(12) D(DF、DY、MD)85-45 [100 D(DF、DY、MD)45]13) D(DF、DY、MD)85-67(14) D(DF、DY、MD)120-50(15) 125D(DF、DY、MD)25(16) D(DF、DY、MD)155-30 [150D(DF、DY、MD)30](17) D(DF、DY、MD)155-67(18) D(DF、DY、MD)280-43 [200D(DF、DY、MD)43](19) D(DF、DY、MD)280-65 [200D(DF、DY、MD)65](20) D(DF、DY、MD)360-40(21) D(DF、DY、MD)450-60(22) D(DF、DY、MD)500-57(23) D(DF、DY、MD)580-60(24) D(DF、DY、MD)600-60(25) D(DF、DY、MD)720-60。

D型煤矿用多级清水离心泵说明书

D型煤矿用多级清水离心泵说明书
校正或更换底阀、清洗或更换吸水管、减低吸水高度。
3、看压力表水泵出口处是有压力而水泵不出水。
出水管阻力太大、旋转方向不对,叶轮淤塞、或损坏,水泵转数不够。
检查或缩短水管及检查电机取下水管接头、清洗或更换叶轮提高转数。
4、流量不足。
水泵淤塞、密封环磨损过多,转数不足。
清洗水泵及管子更换密封环提高转数。
中心线对中是指泵和电动机轴中心线的对正程度。用直尺在两联轴器圆周各个方向测量,两联轴器外圆表面直尺间隙允差应使c≤0.08(见下图),不符合时可用调整垫进行调整。
4.8主要管路的联接
泵灌浆后且紧固在地基上以后,在不受外力条件下对正且联接泵法兰和管路的法兰。这个对正联接不能依靠法兰螺栓的力。
对管路支撑(附加)应避免管路系统的振动,应减少管路对泵的外加力:
10 D型煤矿用多级清水离心泵性能曲线 ……………………(12)
11 D型煤矿用多级清水离心泵安装图 ………………………(47)
12 D型煤矿用多级清水离心泵安装尺寸表 …………………(50)

1概述
1.1 D型泵是卧式或多级单吸清水离心泵:它适用于煤矿输送清水及固体颗粒含量不大于1.5%(体积浓度)的中性矿井水(粒度小于0.5)以及类似的其它污水中,被输进介质温度不高于80℃的泵;
单级扬程(m)单级扬程(m)
流量(m3)多级离心泵
多级离心泵流量(m3)
1.5 产品执行标准:114-2005(煤矿用多级离心泵)
图1
1.瓜型弹性联轴器 2. 轴 3. 滚动轴承体 4. 填料压盖 5. 吸入段 6. 密封环 7. 中段 8. 叶轮 9.导叶 10. 导叶套 11. 平衡水管 12. 吐出段 13. 平衡套(环) 14. 平衡盘 15. 填料函体 16. 轴承

多级离心泵

多级离心泵

多级离心泵简介多级离心泵是一种常见的工业设备,用于将液体从低压区域抽送到高压区域。

它由多个离心式叶轮组成,每个叶轮都会增加一层压力。

在工业生产中,多级离心泵被广泛应用于供水系统、冷却系统、供暖系统以及石油、化工、冶金等领域。

工作原理多级离心泵的工作原理基于离心力和动量原理。

当泵的转子旋转时,叶轮的叶片将液体吸入泵体,并通过离心力将液体抛出。

随着液体通过每个叶轮,其速度增加,压力也相应增加。

每个叶轮都被称为一个级别,整个过程称为多级离心泵。

多级离心泵通常由一个主泵和一组辅助泵组成。

主泵通过驱动系统驱动,将液体从低压区域吸入并将其抛出,辅助泵则用来增加进一步的压力。

通过组合多个级别的泵,可以实现更高的压力。

结构和组成多级离心泵主要由以下组成部分构成:1.泵体:它是泵的主要外壳,用于容纳其他组件。

2.叶轮:叶轮是离心泵的核心部件,由一组叶片构成,通过转子旋转将液体抛出。

3.泵轴:泵轴是连接驱动系统和叶轮的组件,用于传递动力和旋转运动。

4.支座:支座用于支撑泵轴,保持叶轮的平衡和稳定。

5.进口和出口:进口和出口是泵体上的管道接口,用于液体的进入和出来。

6.密封部件:密封部件用于防止液体泄漏,确保泵的正常运行。

7.驱动系统:驱动系统可以是电动机,发动机或其他能源系统,用于驱动泵体。

应用领域多级离心泵被广泛应用于以下领域:1.给水系统:多级离心泵用于将水从水源输送到供水网络中,为居民、工业和商业建筑提供供水服务。

2.冷却系统:多级离心泵将冷却液体抽送到冷却设备中,以防止设备过热。

3.供暖系统:多级离心泵用于将热水或蒸汽输送到供暖设备中,为建筑物提供供暖服务。

4.石油和化工领域:多级离心泵被广泛应用于石油和化工工艺中,用于输送原油、炼油产品和化学品等。

5.冶金领域:多级离心泵用于冶金工艺中的液体输送,如冷却水、冷却剂等。

优势和特点多级离心泵具有以下优势和特点:1.高压能力:多级离心泵可以通过多个级别的叶轮组合实现高压输出,适用于需要高压的应用。

多级离心泵操作规程

多级离心泵操作规程

多级离心泵操作规程多级离心泵操作规程之相关制度和职责,1、开车前先向泵内注水或用真空泵引水。

2、关闭吐出管上的阀及压力表旋塞。

3、启动电机,打开压力表旋塞。

4、当水泵以正常转速运转时,压力表显示适当压力,然后打开真空表旋塞并逐渐打开排水管路上的...1、开车前先向泵内注水或用真空泵引水。

2、关闭吐出管上的阀及压力表旋塞。

3、启动电机,打开压力表旋塞。

4、当水泵以正常转速运转时,压力表显示适当压力,然后打开真空表旋塞并逐渐打开排水管路上的闸阀,直至达到规定的雨衣力及真空度。

5、水泵停用时先要慢慢关闭排水管路上的闸阀、关闭真空表旋塞,并停止电机,然后关闭压力表旋塞。

6、如长期停用水泵,应拆卸泵体将泵零件的水擦拭干,并在滑动面上涂上以防锈油妥善保存。

7、水泵运转时应经常检查水泵及<电机轴承温度,不得超过外界温度35℃,其极限温度不得大于75℃BR>8、在轴承体内时常驻要注意加油。

9、随时调整填料压盖的松紧程度,正常漏水以点滴为宜。

10、运转过程中如发生噪音或异常的声音时,应立即停车检查。

篇2:IH化工离心泵操作规程一、泵的启动1、运转前应检查泵转动是否灵活;机械密封应无摩擦现象;储油器油位是否正常;电机转动方向是否正职。

2、关闭泵出口阀门;3、对外部有冲洗的机械密封,起动前应先开启冲洗液使密封腔内充满密封液;4、检查引水是否正常(使液体充满泵腔);5、接通电源,当电机达到额定转速后逐渐开启出口阀门(泵出口阀门关闭时泵连续工作时间不能超过3分钟)。

二、泵的运转1、经常检查泵和电机的发热情况(轴承温度≤750C);2、经常检查机械密封的密封性能;3、轴承润滑油加注量以油位计中心线2mm左右;4、注意电动机电流、温度等参数是否在规定范围内;5、不能用吸入管上的阀门调节泵的流量,避免产生气蚀;6、泵不能在低于30%设计流量下长期运转;三、停车1、缓慢关闭出口管路阀门,并关闭各种仪表开关;2、切断电源;3、关闭密封冲洗液。

型原D型卧式多级离心泵性能参数

型原D型卧式多级离心泵性能参数

D型(原DA1型)卧式多级离心泵(性能参数)?如D(DF、DY、MD)600-60×6 D?????---- 表示多级清水离心泵DF??? ---- 表示耐腐多级离心泵DY??? ---- 表示多级离心油泵MD??? ---- 表示耐磨多级离心泵600?? ---- 表示设计点流量为600m3/h 60???? ---- 表示设计点单级扬程为60m 6?????? ---- 表示级数为6级如150D30×7150???---- 表示泵吸入口直径为150mm D??????---- 表示多级离心清水泵30???? ---- 表示泵设计点单级扬程为30m 7?????? ----表示级数为7级(1) D(DF、DY、MD)6-25(2) D(DF、DY、MD)6-50(3) D(DF、DY、MD)12-25(4) D(DF、DY、MD)12-50(5) D(DF、DY、MD)25-30(6) D(DF、DY、MD)25-50(7) 80D(DF、DY、MD)12(8) D(DF、DY、MD)80-30(9) D(DF、DY、MD)46-30(10) D(DF、DY、MD)46-50(11) 100D(DF、DY、MD)16(12) D(DF、DY、MD)85-45? [100 D(DF、DY、MD)45]13) D(DF、DY、MD)85-67(14) D(DF、DY、MD)120-50(15) 125D(DF、DY、MD)25(16) D(DF、DY、MD)155-30?[150D(DF、DY、MD)30](17) D(DF、DY、MD)155-67(18) D(DF、DY、MD)280-43 [200D(DF、DY、MD)43](19) D(DF、DY、MD)280-65 [200D(DF、DY、MD)65](20) D(DF、DY、MD)360-40(21) D(DF、DY、MD)450-60(22) D(DF、DY、MD)500-57(23) D(DF、DY、MD)580-60。

d型原da型卧式多级离心泵性能参数

d型原da型卧式多级离心泵性能参数

D型(原DA1型)卧式多级离心泵(性能参数)?如D(DF、DY、MD)600-60×6 D?????---- 表示多级清水离心泵DF??? ---- 表示耐腐多级离心泵DY??? ---- 表示多级离心油泵MD??? ---- 表示耐磨多级离心泵600?? ---- 表示设计点流量为600m3/h 60???? ---- 表示设计点单级扬程为60m 6?????? ---- 表示级数为6级如150D30×7150???---- 表示泵吸入口直径为150mm D??????---- 表示多级离心清水泵30???? ---- 表示泵设计点单级扬程为30m 7?????? ----表示级数为7级(1) D(DF、DY、MD)6-25(2) D(DF、DY、MD)6-50(3) D(DF、DY、MD)12-25(4) D(DF、DY、MD)12-50(5) D(DF、DY、MD)25-30(6) D(DF、DY、MD)25-50(7) 80D(DF、DY、MD)12(8) D(DF、DY、MD)80-30(9) D(DF、DY、MD)46-30(10) D(DF、DY、MD)46-50(11) 100D(DF、DY、MD)16(12) D(DF、DY、MD)85-45? [100 D(DF、DY、MD)45]13) D(DF、DY、MD)85-67(14) D(DF、DY、MD)120-50(15) 125D(DF、DY、MD)25(16) D(DF、DY、MD)155-30? [150D(DF、DY、MD)30](17) D(DF、DY、MD)155-67(18) D(DF、DY、MD)280-43[200D(DF、DY、MD)43](19) D(DF、DY、MD)280-65 [200D(DF、DY、MD)65](20) D(DF、DY、MD)360-40(21) D(DF、DY、MD)450-60(22) D(DF、DY、MD)500-57(23) D(DF、DY、MD)580-60。

达迪维多阶段钢丝泵说明书

达迪维多阶段钢丝泵说明书

P R O D U C TD E S C R I P T I O NRobust & compact, multi-stage stainless steel centrifugal pumps, driven by a TEFC motor. Designed for total head duties to 32m and flows to 230lpm.A P P L I C AT I O N SIdeal for pumping clean, non-volatile,non-aggressive liquids without fibres or solids in such applications as:-•Vat washing•Washing systems•Domestic water supply •Irrigation•Water transfer •Pressure boostingO P E R AT I N G L I M I T SF E AT U R E S & B E N E F I T SPumpMultistage, closed vane 304 stainless steel impellers with full length “D”drives, provide:•Superior reliability when pumpingcorrosive water•Easy assembly and servicing Corrosion resistant 316 stainless steel pump shaft and 304 stainless steel casing for long service life.High quality mechanical shaft seal for long life and reliability.Patented floating impeller neck rings provide:•High efficiency•Quieter pump operationMotorThe Davey manufactured TEFC motor has an IP55 enclosure providing:•Excellent corrosion resistance •High levels of resistance to dustand rain•Ability to operate reliably in highambient temperaturesMotor continued...Single phase motors are permanently split capacitor design for:•Reliable starting even in lowvoltage circumstances •Superior frequent startingperformance Single phase motors are protected against both high operatingtemperatures and high current by a built in, automatically resetting thermal overload.All single phase models come with a 2metre power lead, and are available with a choice of connectors or plugs to suit.Double contact C3-HTG sealed bearings for quieter running and longer life.Corrosion resistant feet on motor shell, include three point bolt-down facilityStandard models are 220/240 volt,50Hz, single phase or 380/415V50Hz, three phase. Choice of models in 60Hz 110/115 volt and 220/230volt single phase available on request.XF92SS XF192SS XF242SSCapacities to 140lpm 200lpm 240lpm Maximum total head 30m 31m 32m Maximum suction head 7.0m7.5m7.5mMaximumwater temperature continuous65o C 15 minute peak 85o C Minimum water temperature 1o C Maximum ambient temperature 55o C Inlet size 11/4” BSP(F)Outlet size 1” BSP(F)Maximum pump casing pressure450kPaTRANSFER PUMPSM AT E R I A L S O F C O N S T R U C T I O N PA R T M AT E R I A LImpellersImpeller spacer Lock nutPump casing Clamp bandPump shaftSeal ring (stationary) Seal ring (rotating) Seal springO-ringsDiffusersBlanking ring NeckringsMotor shellShell finishPriming plug 304 stainless steel304 stainless steel316 stainless steel304 stainless steel304 stainless steel316 stainless steel CeramicCarbon304 stainless steel Nitrile rubberGlass filled norylGlass filled noryl PolypropyleneMarine grade aluminium Baked polyester Chromium plated brassE L E C T R I C A L D ATATOTAL HEAD (m)FLOW (lpm)D I ME N S I O N SDavey Products Pty LtdMember of the GUD Holdings Ltd GroupABN 18 066 327 517Head Office and Manufacturing6 Lakeview Drive,Scoresby, Australia 3179Ph:+61 3 9730 9222Fax:+61 3 9753 4100Website:.auCustomer Service CentrePh:1300 367 866Fax:1300 369 119E-mail:***************.auInterstate OfficesSydney - Brisbane - AdelaidePerth - TownsvilleInternational6 Lakeview Drive,Scoresby, Australia 3179Ph:+61 3 9730 9121Fax:+61 3 9753 4248E-mail:****************.auGermanyKantstrasse 47,04275 LeipzigPh:+49 341 301 0412Fax:+49 341 301 0413E-mail:******************New Zealand220A Bush Road,North Harbour, Auckland 1330Ph:+64 9 914 3680Fax:+64 9 914 3685Website:E-mail:****************.nzUSA1005 N. Commons DriveAurora, Illinois 60504Ph:+1 630 898 6976Fax:+1 630 851 7744Website:E-mail:******************Product specifications may change without notice.® Davey is a registered trademark of Davey Products Pty Ltd. © Davey Products Pty Ltd 2002.D949/3K/0104/GPW supersedes D895-1/1K/0503/GPW。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

一、概述
1、编制依据:GB9969.1-1998《工业产品使用说明书总则》。

2、产品执行标准:GB/T5657-95《离心泵技术条件(III类)》。

3、产品性能范围及适用范围:
DA型泵是单吸多级分段式离心泵,供抽送清水及物理化学类似于水的液体之用。

本型泵扬程在14米~207米,流量为10.8米3/时~126米3/时范围,液体最高温度不得超过80℃,适用于矿山、工厂及城市给排水之用。

4、泵型号代表的含义:例:
二、结构说明
DA型泵为分段式多级泵,其吸入口位于进水段上成水平方向,吐出口在出水段上垂直向上。

其扬程可根据使用需要而增减水泵级数,本型泵装配精度对性能影响特别显著,尤其是各个叶轮的出口与导翼进口之间相对位置,每级叶轮的吐出口中心必须对准导翼的进口中心,其中稍有偏差即将使整个性能受到影响、效率降低,故在检修后装配时务必注意,若有偏差必须调整,从驱动方向看,水泵均为顺时针方向旋转。

DA型泵结构图
2DA-8型泵工作性能表
四、泵的装配与安装
☆装配顺序:
1、将密封环紧装在进水段上。

2、把导翼套装在导翼上,然后将导翼固定在所有的中段上去。

3、将出水导翼、平衡环和平衡套分别装在出水段上。

4、将装好轴套甲和键的轴穿过进水段,并顺键推入叶轮、叶轮挡套并在中段上铺一层青壳纸,装好中段再顺键推进叶轮、叶轮挡套,重复以上步骤将所有叶轮、叶轮挡套及中段装完。

5、将出水段装在中段上,然后由拉紧螺栓将进水段、中段和出水段紧固在一起。

6、装上平衡盘及轴套乙。

拧上轴套螺母,并将尾盖紧固在出水段上。

7、顺次在二端放入填料环里面的填料、填料环、填料压盖及挡水圈,井将轴承甲、乙部件分别紧固在进水段和尾盖上。

装好后,转动一下轴,检查转子部分是否灵活。

8、装好填料环外面的填料和填料压盖。

注意填料环串孔中心应对准水封管中心。

9、装上水封管、回水管、弹性联轴器部件及所有四方螺塞。

☆泵的安装:
1、安装前的准备工作
(1)泵的基础必须具有足够的强度,基础的质量约等于机组质量的3~5倍。

(2)检查水泵和电机,检查泵的零件是否有严重磕碰现象。

(3)检查泵的零配件是否缺少或损坏。

(4)准备工具及起重机械。

☆安装顺序:
(1)在底座下面放置钢的垫铁和楔铁。

用起重吊钩吊住底座的四个角,把底座吊在地基上方,慢慢地把底座放在每一个预制好的地脚螺栓孔的位置上。

(2)找平底座,向地脚处灌浆,达到凝固强度后,拧紧地脚螺栓。

(3)设备调整。

泵与电机联轴器之间应有间隙,一般间隙应有3~6毫米左右。

水泵与电机的轴线应重合,可用塞尺测量两联轴器端面问隙的均匀度,其允差为0.06毫米,可用直尺在两联轴器圆周各个方向进行测量,两联轴器外圆表面间隙允差0.08毫米。

如不符以上要求,可用调整垫进行调整。

☆管道安装及注意事项:
(1)泵的出水口必须安装压力表,闸阀及止回阀。

进水处应安装真空表、底阀(用真空泵引水可不安装底阀)。

(2)进水管道的进口处应安装过滤网,防止大的颗粒进入泵中,损坏设备。

(3)不得将管路重量压在泵上,使泵受力。

泵停后,不得使泵承受管路中水的重力。

(4)泵的平衡水管是连接进水段和出水段的一根管,它起着平衡轴向力的作用,绝对不允许堵塞,一般泵出厂时已连接好,用户不需要再安装调整。

(5)水封管是连接进水段填料腔和填料函体填料腔的一根管,它起到防止泵内进气、水润滑及水冷却的作
(6)必须采用不小于水泵进水口径的管子进行安装,否则会影响水泵的性能。

(7)管道在距离1米范围内尽可能不拐弯,以减少阻力损失。

(8)管道安装完毕后,必须进行冲洗方可与泵连接,防止焊渣等杂质进入泵内,损坏叶轮。

五、操作与使用
☆启动前
(1)用手转动联轴器,泵的转动部分旋转应该灵活均匀。

每次启动泵都应重复进行此操作,发现卡死现象应即时维修。

(2)向泵内注满水或抽出泵内空气,并关闭泵出口管路上的闸阀和压力表旋塞。

要保证泵内充满水,无空气窝存。

(3)瞬间启动一下电机,检查泵的旋转方向是否正确。

水泵的选装方向:从电机方向看泵为顺时针方向选装。

(4)启动泵后,打开压力表旋塞、真空表旋塞,并逐渐打开泵出口管路上的闸阀,待压力表显示压力满足要求即可。

☆运转
(1)注意水泵轴承温度,其最高温度不得高于70℃,温升不得高于35℃。

(2)填料的松紧程度应适应,每分钟的渗水量为10~20滴,否则应调整填料压盖。

但填料不能压的太紧,否则会使电机电流升高或烧坏填料。

(3)定期检查联轴器,泵、电联轴器是否出现裂痕,螺栓是否松动等现象。

(4)水泵每工作1000小时,应进行检修,叶轮与密封环的间隙因磨损超过最大值的两倍时,应更换密封环。

(5)泵只允许在说明书规定的参数范围内运转。

禁止超大流量运行,以免超负荷及振动、噪音加剧。

(6)泵不允许在出口阀门关闭或很小开度下长时间运转,否则导致泵发热,降低寿命。

(7)泵不能关吸入阀运行,也不能用吸入阀来调节流量,以免产生汽蚀而损坏泵。

(8)运转过程中,发现噪音或不寻常的声音,应立即停车,检查其原因。

(9)用户应根据说明书要求和现场情况,定制出合理的操作规程。

☆停车
慢慢关闭出水管路上的闸阀和压力表旋塞,进水口管路上的真空表旋塞,然后切断电动机电源。

六、泵的维护与保养
1、用户应制定出泵的维护保养制度
(1)检查泵的底座、泵的电动机固定螺栓是否松动。

(2)检查仪表、引线的状况是否损坏或老化,检查管路是否泄漏或松动。

(3)水泵工作的第一个月内,经过100小时后轴承应当换油一次,以后每工作2000小时换油一次。

(4)冬季暂停停泵时,应将泵底部所有丝堵拧开,把泵内的水放掉避免将水泵冻坏。

(5)长期不用泵时,应将泵卸掉,拆开,将零件涂防锈油,妥善保存。

(6)每次停机后,再启动泵时,先用手转动联轴器,看泵的转子转动是否灵活,有无卡死现象。

(8)定期检查泵的性能及运行情况,并做详细记录,如发现问题应立即维修。

七、可能发生的故障及其解决方法
九、DA泵安装尺寸图(一)
十、DA泵安装尺寸图(二)
DA泵安装尺寸图(二)。

相关文档