JHHK-1HA说明书
паркер汉尼夫公司水力系列产品目录说明书

ABV101............Accumulator Bleed-Down Valve......................MV15-MV17 CDP161............Double P.O. Check Valves..................................LH85-LH86 CDPH103..........Double P.O. Check Valves..................................LH83-LH84 CP044P............Single P.O. Check Valves...................................LH46-LH48 CP074P............Single P.O. Check Valves...................................LH49-LH51 CP084P............Single P.O. Check Valves...................................LH52-LH54 CPC101P..........Pilot-to-Close Check Valves...............................LH64-LH66 CPC161P..........Pilot-to-Close Check Valves...............................LH67-LH69 CPD084P..........Double P.O. Check Valves..................................LH80-LH82 CPH064P..........Single P.O. Check Valves...................................LH55-LH57 CPH104P..........Single P.O. Check Valves...................................LH58-LH60 CPH124P..........Single P.O. Check Valves...................................LH61-LH63 CS041B............Shuttle Valves....................................................LH87-LH89 CSH101B..........Shuttle Valves....................................................LH90-LH92 CSP161............Single P.O. Check Valves...................................LH78-LH79 CSPH103..........Single P.O. Check Valves...................................LH76-LH77 CV041P............Check Valves.........................................................LH1-LH3 CV081P &091P.................Check Valves.........................................................LH4-LH6 CV082P............Check Valves.........................................................LH7-LH9 CV101P............Check Valves.....................................................LH10-LH12 CV102P............Check Valves.....................................................LH13-LH15 CV103P............Check Valves.....................................................LH16-LH18 CVH061P..........Check Valves.....................................................LH25-LH27 CVH071P..........Check Valves.....................................................LH28-LH30 CVH081P &091P.................Check Valves.....................................................LH31-LH33 CVH103P..........Check Valves.....................................................LH34-LH36 CVH084P..........Check Valves.....................................................LH37-LH39 CVH104P..........Check Valves.....................................................LH40-LH42 CVH121P..........Check Valves.....................................................LH43-LH45 CVH161P..........Check Valves.....................................................LH19-LH21 CVH201P..........Check Valves.....................................................LH22-LH24 CVO101P..........Vent-to-Open Check Valves...............................LH70-LH72 CVO161P..........Vent-to-Open Check Valves...............................LH73-LH75 DF083...............Sol. Operated, P.C. Proportional Flow Cont...........PV1-PV4 DF092C............Sol. Operated, P.C. Proportional Flow Cont...........PV5-PV8 DF092N............Sol. Operated, P.C. Proportional Flow Cont.........PV9-PV12 DF102C............Sol. Operated, P.C. Proportional Flow Cont.......PV13-PV16 DF102N............Sol. Operated, P.C. Proportional Flow Cont.......PV17-PV20 DF102P............Sol. Operated, P.C. Proportional Flow Cont.......PV21-PV23 DF122...............Sol. Operated, P.C. Proportional Flow Cont.......PV24-PV27 DF161C............Solenoid Operated, Throttle Valves....................PV28-PV31 DF201C............Solenoid Operated, Throttle Valves....................PV32-PV35 DH082..............Pilot Operated, 2-Way Valves............................DC22-DC24 DH103..............Pilot Operated, Directional Valves......................DC25-DC28 DL081..............Manual, Poppet-Type, 2-Way Valves.....................DC1-DC3 DL101..............Manual, Poppet-Type, 2-Way Valves.....................DC4-DC6 DL102..............Manual, Spool-Type, 2-Way Valves.......................DC7-DC9 DL103..............Manual, Spool-Type, 3-Way Valves...................DC10-DC12 DL104..............Manual, Spool-Type, 4-Way Valves...................DC13-DC15 DM103.............Manual, Rotary, 3-Way Valves...........................DC16-DC18 DM104.............Manual, Rotary, 4-Way Valves...........................DC19-DC21 DPR083B..........Sol. Operated, Proportional Pres. Reducing......PV36-PV39 DPR083C..........Sol. Operated, Proportional Pres. Reducing......PV40-PV43 DPR083C30......Sol. Operated, Proportional Pres. Reducing......PV44-PV47 DPR083N.........Sol. Operated, Proportional Pres. Reducing......PV48-PV51 DPR103C..........Sol. Operated, Proportional Pres. Reducing......PV52-PV55DPR104C10......Sol. Operated, Proportional Pres. Reducing......PV56-PV59 DS085..............Solenoid, Spool-Type, 4-Way, 3-Pos.............DC127-DC130 DS086C6Mand 096............Sol., Bi-Directional, Poppet-Type, 2-Way.......DC148-DC151 DS105..............Solenoid, Spool-Type, 4-Way, 3-Pos.............DC131-DC134 DS161..............Solenoid, Poppet-Type, 2-Way Valves...............DC56-DC59 DS162..............Solenoid, Spool-Type, 2-Way Valves.................DC84-DC87 DS123B............Solenoid, Spool-Type, 3-Way Valves.............DC104-DC106 DS163..............Solenoid, Spool-Type, 3-Way Valves.............DC107-DC110 DS201..............Solenoid, Poppet-Type, 2-Way Valves...............DC60-DC63 DS083BP3........Solenoid, Poppet-Type, 3-Way Valves...............DC64-DC67 DSH08D1C.......Solenoid, Poppet-Type, 2-Way Valves...........DC139-DC141 DSH08D6C.......Solenoid, Poppet-Type, 2-Way Valves...........DC145-DC147 DSH081 & 091.Solenoid, Poppet-Type, 2-Way Valves...............DC36-DC39 DSH082 & 092.Solenoid, Spool-Type, 2-Way Valves.................DC72-DC75 DSH083............Solenoid, Spool-Type, 3-Way Valves.................DC92-DC95 DSH084............Solenoid, Spool-Type, 4-Way Valves.............DC115-DC118 DSH085............Solenoid, Spool-Type, 4-Way, 3-Pos.............DC135-DC138 DSH101............Solenoid, Poppet-Type, 2-Way Valves...............DC44-DC47 DSH102............Solenoid, Spool-Type, 2-Way Valves.................DC80-DC83 DSH103............Solenoid, Spool-Type, 3-Way Valves.............DC100-DC103 DSH104............Solenoid, Spool-Type, 4-Way Valves.............DC123-DC126 DSH106C6........Sol., Bi-Directional, Poppet-Type, 2-Way.......DC156-DC159 DSH121............Solenoid, Poppet-Type, 2-Way Valves...............DC52-DC55 DSL08D6C........Sol., Bi-Directional, Poppet-Type, 2-Way.......DC142-DC144 DSL080DC........Soft Seat, Direct Act., Poppet-Type, 2-Way.......DC29-DC31 DSL081 & 091.Solenoid, Poppet-Type, 2-Way Valves...............DC32-DC35 DSL082 & 092.Solenoid, Spool-Type, 2-Way Valves.................DC68-DC71 DSL083............Solenoid, Spool-Type, 3-Way Valves.................DC88-DC91 DSL084............Solenoid, Spool-Type, 4-Way Valves.............DC111-DC114 DSL101............Solenoid, Poppet-Type, 2-Way Valves...............DC40-DC43 DSL102............Solenoid, Spool-Type, 2-Way Valves.................DC76-DC79 DSL103............Solenoid, Spool-Type, 3-Way Valves.................DC96-DC99 DSL104............Solenoid, Spool-Type, 4-Way Valves.............DC119-DC122 DSL106C6........Sol., Bi-Directional, Poppet-Type, 2-Way.......DC152-DC155 DSL121............Solenoid, Poppet-Type, 2-Way Valves...............DC48-DC51 EHVC................Electrohydraulic Valve Controller.......................PV92-PV99 ERV091C..........Solenoid Operated, Proportional P.C.................PV60-PV63 ERV091N..........Solenoid Operated, Proportional P.C.................PV64-PV67 ERV092N..........Solenoid Operated, Proportional P.C.................PV68-PV71 ERV101C..........Solenoid Operated, Proportional P.C.................PV72-PV75 ERV101N..........Solenoid Operated, Proportional P.C.................PV76-PV79 ERV102N..........Solenoid Operated, Proportional P.C.................PV80-PV83 ERV121N..........Solenoid Operated, Proportional P.C.................PV84-PV87 ERV161N..........Solenoid Operated, Proportional P.C.................PV88-PV91 FA101...............Pressure Compensated Flow Control................VC16-VC18 FC101...............Pressure Compensated Flow Control................VC22-VC24 FCP101.............Priority-Type, P.C. Valves...................................VC38-VC40 FCPH121..........Priority-Type, P.C. Valves...................................VC41-VC43 FCR101............Restrictive-Type, P.C. Valves..............................VC29-VC31 FCR121............Restrictive-Type, P.C. Valves..............................VC32-VC34 FCR161............Restrictive-Type, P.C. Valves..............................VC35-VC37 FDC101............Flow Divider/Combiner Valves...........................VC19-VC21 FL101...............Filter Cartridge.....................................................MV7-MV9 FP101...............Priority-Type, P.C. Flow Control Valves..............VC47-VC50 FPR101............Priority-Type, P.C. Flow Control Valves..............VC51-VC53 FR101...............Restrictive-Type, P.C. Flow Control Valves.........VC44-VC46FV101 & 102 .... Flow Control Valves ........................................... VC25-VC28 HLSVH101........Hi-Lo Unloading Valve.....................................MV10-MV12 HP101..............Hand Pump.....................................................MV13-MV14 NV102..............Needle Valves........................................................VC7-VC9 NV161..............Needle Valves....................................................VC10-VC12 NV162..............Needle Valves....................................................VC13-VC15 NVH081............Needle Valves........................................................VC1-VC3 NVH101............Needle Valves........................................................VC4-VC6 Offer of Sale............................................................................................TI15 P10-2*.............Cavity Plugs................................................................MV19 PDS101............Pressure Sensing..............................................PC67-PC69 PDS161............Pressure Sensing..............................................PC70-PC72 PMK101...........Panel Mount Kit..........................................................MV18 PN 812724.......Block Off Plate............................................................MV20 PR103..............Pressure Reducing/Relieving Valves.................PC91-PC93 PRCH101..........Pressure Reducing/Relieving Valves With.........................PC79-PC81PRH081............P.O. Pressure Reducing/Relieving Valves..........PC73-PC75 PRH082............P.O. Pressure Reducing Valves..........................PC94-PC96 PRH101............P.O. Pressure Reducing/Relieving Valves..........PC76-PC78 PRH102............P.O. Pressure Reducing Valves..........................PC97-PC99 PRH121............P.O. Pressure Reducing/Relieving Valves..........PC82-PC84 PRH121V..........P.O. Pressure Reducing/Relieving Valves..........PC85-PC87 PRH122............P.O. Pressure Reducing Valves......................PC100-PC102 PRH161............P.O. Pressure Reducing/Relieving Valves..........PC88-PC90 PRH162............P.O. Pressure Reducing Valves......................PC103-PC105PRS102............Pressure Reducing Spool Valves...................PC106-PC108PRS162............Pressure Reducing Spool Valves...................PC109-PC111 RAH081 & 091.P.O. Relief Valves...............................................PC49-PC51 RAH101............P.O. Relief Valves...............................................PC52-PC54 RAH101V..........P.O. Ventable Relief Valves................................PC55-PC57 RAH121............P.O. Relief Valves...............................................PC58-PC60 RAH161............P.O. Relief Valves...............................................PC61-PC63 RAH201............P.O. Relief Valves...............................................PC64-PC66 RASPH21.........Subplate/Relief Valve...........................................MV1-MV3 RASPH31.........Subplate/Relief Valve...........................................MV4-MV6 RD042..............Direct Acting Relief Valves.....................................PC7-PC9 RD072..............Direct Acting Relief Valves.................................PC13-PC15 RD102..............Direct Acting Relief Valves.................................PC19-PC21 RD163..............Direct Acting Relief Valves.................................PC31-PC33 RDH062............Direct Acting Relief Valves.................................PC10-PC12 RDH081............Direct Acting Relief Valves.....................................PC1-PC3 RDH082............Direct Acting Relief Valves.................................PC16-PC18 RDH083............Direct Acting Relief Valves.................................PC22-PC24 RDH101............Direct Acting Relief Valves.....................................PC4-PC6 RDH103............Direct Acting Relief Valves.................................PC25-PC27 RDH104............Differential Relief Valves With..........................................PC34-PC36 RDCH103.........Direct Acting Relief Valves With..........................................PC28-PC30PC139-PC141 SVCH101..........Sequence Valves w/Free Rev. Flow Check.....PC118-PC120 SVH081............Sequence Valves............................................PC112-PC114 SVH082............P.O. Sequence Valves....................................PC127-PC129 SVH101............Sequence Valves............................................PC115-PC117 SVH102............P.O. Sequence Valves....................................PC130-PC132 SVH121............Sequence Valves............................................PC121-PC12308 & 09............Coils 1/2″ I.D..........................................................CL1-CL2 DF102P &DPR104C10......Coils 1/2″ I.D..........................................................CL3-CL4 10, 12,16 & 20............Coils 5/8″ I.D..........................................................CL5-CL6 12 & 16............Coils 1″ I.D.............................................................CL7-CL8 08 & 09............Unicoils 1/2″ I.D...................................................CL9-CL10 10 & 12............Unicoils 5/8″ I.D.................................................CL11-CL12 08 & 09............Waterproof Coils 1/2″ I.D............................................CL13 10 & 12............Waterproof Coils 5/8″ I.D............................................CL14 Installation Data.........................................................................................TI1 04.....................Two and Three Way Cavity Details..................................TI206.....................Two and Three Way Cavity Details..................................TI307.....................Two and Three Way Cavity Details..................................TI408.....................Two, Three and Four Way Cavity Details...................TI5-TI609.....................Two Way Cavity Detail....................................................TI710.....................Two, Three and Four Way Cavity Details...................TI8-TI9 12.....................Two, Three and Four Way Cavity Details...............TI10-TI11 16.....................Two, Three and Four Way Cavity Details...............TI12-TI13 20.....................Two Way Cavity Detail..................................................TI14 B04-2**...........Single Function, Two Step Bodies.........................VB1-VB2 B04-3**...........Single Function, Three Step Bodies.......................VB3-VB4 B06-2**...........Single Function, Two Step Bodies.........................VB5-VB6 B06-3**...........Single Function, Three Step Bodies.......................VB7-VB8 B07-2**...........Single Function, Two Step Bodies.......................VB9-VB10 B07-3**...........Single Function, Three Step Bodies...................VB11-VB12 B08-2**...........Single Function, Two Step Bodies.....................VB13-VB14 B08-3**...........Single Function, Three Step Bodies...................VB15-VB16 B08-4**...........Single Function, Four Step Bodies.....................VB17-VB18 B09-2**...........Single Function, Two Step Bodies.....................VB19-VB20 B10-2**...........Single Function, Two Step Bodies.....................VB21-VB22 B10-2T**.........Single Function, Two Step Bodies.....................VB23-VB24 B10-3**...........Single Function, Three Step Bodies...................VB25-VB26 B10-3L**.........Single Function, Three Step Bodies...................VB27-VB28 B10-4**...........Single Function, Four Step Bodies.....................VB29-VB30 B12-2**...........Single Function, Two Step Bodies.....................VB31-VB32 B12-3**...........Single Function, Three Step Bodies...................VB33-VB34 B12-4**...........Single Function, Four Step Bodies.....................VB35-VB36 B16-2**...........Single Function, Two Step Bodies.....................VB37-VB38 B16-3**...........Single Function, Three Step Bodies...................VB39-VB40 B16-3S**.........Single Function, Three Step Bodies...................VB41-VB42 B20-2**...........Single Function, Two Step Bodies.....................VB43-VB44 Single Function BodiesCavity DetailsCartridge Valve CoilsSVH122............P.O. Sequence Valves....................................PC133-PC135 SVH161............Sequence Valves............................................PC124-PC126 SVH162............P.O. Sequence Valves....................................PC136-PC138 TR081..............Thermal Relief Valves....................................PC142-PC144 VF101...............Velocity Fuses....................................................VC54-VC56 XR101..............Cross-Over Relief Valves...................................PC37-PC39 XRDH101.........Cross-Over Relief Valves...................................PC40-PC42 XRDH102.........Dual Relief Valves w/Anti-Cavitation Checks......PC43-PC45 XRDH103.........Cross-Over Relief Valves...................................PC46-PC48。
GEFRAN智能HART熔化压力变送器HW、HM、HK系列说明书

SMART HART MELT PRESSURE TRANSMITTERSHW, HM, HK SERIESINSTRUCTION MANUALcod. 80169I Edit. 12/2021 - ENGATTENTION!This manual is an integral part of the product,and must always be available to operators.This manual must always accompany theproduct, including if it is transferred to another user.Installation and/or maintenance workers MUSTread this manual and scrupulously follow all of the instructions in it and in its attachments.GEFRAN will not be liable for damage topersons and/or property, or to the product itself, if the following terms and conditions are disregarded.The customer must respect trade secrets.Therefore, this manual and its attachments maynot be tampered with, changed, reproduced, or trans-ferred to third parties without GEFRAN’s authorization.T h i s d o c u m e n t i s t h e p r o p e r t y o f G E F R A N a n d m a y n o t b e r e p r o d u c e d o r t r a n s f e r r e d t o t h i r d p a r t i e s w i t h o u t a u t h o r i z a t i o n .Gefran Smart HART series ➡ READY-TO-USE GUIDE ��������������������������������������������������������������������������������������������������������4. READY-TO-USE Using magnetic pen / pin CAL feature (4). READY-TO-USE Using HART Communicator (4). Menu Tree ➡ H Pres Transmitter (5)1� GENERAL INFORMATION ���������������������������������������������������������������������������������������������������������������������������������������������������6 1.1. General information (6)1.2. Copyright (6)1.3. Correct use (6)2� ACRONYMS ��������������������������������������������������������������������������������������������������������������������������������������������������������������������������6 3� NAME CODING ���������������������������������������������������������������������������������������������������������������������������������������������������������������������7 4� SENSOR TECHNICAL SPECIFICATIONS ��������������������������������������������������������������������������������������������������������������������������8 5� MECHANICAL DIMENSIONS ���������������������������������������������������������������������������������������������������������������������������������������������13 6� INSTALLATION AND POSITIONING ON THE MACHINE ������������������������������������������������������������������������������������������������13 6.1. Installation seat (13)6.2. Drilling Tool Kit (14)6.3. Wiring and calibration (16)7� ELECTRICAL CONNECTIONS �����������������������������������������������������������������������������������������������������������������������������������������17 8� COMMAND MODES ����������������������������������������������������������������������������������������������������������������������������������������������������������19 8.1. Using Magnetic pen and Pin CAL (19)8.2. Using HART Communication (21)9� MAINTENANCE ������������������������������������������������������������������������������������������������������������������������������������������������������������������27 9.1. Transport, storage and disposal (27)10� FUNCTIONAL SAFETY NOTES (for SIL 2 / PL d certified versions only) �������������������������������������������������������������������28 10.1. NE21 and NE43 compatibility specifications (33)11� RELAY APPLICATION NOTES ������������������������������������������������������������������������������������������������������������������������������������������34 12� SAFETY NOTES FOR APPLICATIONS IN POTENTIALLY EXPLOSIVE ATMOSPHERES: HWX AND HMX VERSIONS ����38 12.1. NEPSI Ex requirements (39)13� ANNEXES ��������������������������������������������������������������������������������������������������������������������������������������������������������������������������40This Ready-to-Use guide can be used by expert instrumentation operators to configure the transmitter using HART Communication or Autozero/Calibration features through magnetic pen or contacts on output connector.For more full information please refer to the complete manual before operating.The Ready-to-Use procedure with HART is intended for users already familiar with HART Communicator and loop powered equipment.READY-TO-USE Using magnetic pen / pin CAL featureBring the system to the working temperature with the transmitter installed and connected to the measurement instrument without any pressure applied. For a 6 or 8 pin connector version, Pin A is Sig+/Exc+ and pin B is Sig-/Exc-.For conduit output configurations, please look at Electrical Connections chapter.Assure proper loop feeding voltage is applied to transmitter.The measurement chain connected to the transmitter is calibrated as follows:1) Reset the offset on the instrument by eliminating the thermal drift with the Autozero function.With the sensor installed and the extruder at working temperature, wait until the temperature itself is stable, with a pos- sible variation of ± 1°C. Consequently Autozero can be activated.This allows to compensate all the signal drifts caused by tightening and temperature. Additional Autozero activations could be run once the temperature stability is reached, with ± 1°C of possible variation.2) Calibrate the instrument activating the CAL function.The transducer brings its output to the calibration value shown on the transducer data plate (80% of full scale default, if changed with HART command it could be different). With the external Autozero function the calibration procedure is not feasible.3) If the instrument does not exactly indicate zero, repeat points 1) and 2).READY-TO-USE Using HART CommunicatorBring the system to the working temperature with the transmitter installed and connected to the measurement instrument without any pressure applied.1) Connect Communicator to the loop. In case it’s not sure on how to do this, please refer to “Connecting the HART Handheld Communicator” (Figure 8.1).2) Switch on HART Communicator. For reference please refer to HART Command tree on the following page.3) From the main menu:a. Enter Tag (Fast Key 1, 3, 1)b. Set Pressure Units (Fast Key 1, 3, 3), if neededc. Set URV (Fast Key 1, 3, 4) if output turndown (rescaling), is neededd. Perform Autozero (Fast Key 1, 2, 6, 3, 1)4) Check loop output is zero (4mA).5) Remove HART Communicator from loop.Menu Tree H Pres Transmitter(*) Equal to 0 for HM, HW, HK (≠ 0 for HI).This manual applies to the following products:HME, HWE, HKE series as well as HMX and HWX, series produced by Gefran spa, via sebina 74 – 25050 Provaglio di Iseo - BS - Italy.1.1 General informationThis manual must be kept near the equipment for easy reading and consultation.It must be read, understood, and strictly follow in order to avoid and prevent accidents and/or malfunctions.Gefran will not be liable for any injury to people and/or damage to property deriving from disregard of this manual.1.2 CopyrightAny reproduction of this document, even partial or for internal use, requires Gefran’s approval.1.3 Correct useGefran Melt pressure sensors with amplified current output with HART protocol are designed and builtto measure the pressure and temperature variable of melted plastic at different temperatures accor-ding to the filling fluid used. The correct temperature range is:• Up to 315°C for HW series (i.e. oil filling fluid)• Up to 400°C for HM series (i.e. mercury filling fluid)• Up to 538°C for HK series (i.e. Na-K filling fluid)If the sensors are used as a safety component in compliance with the Machinery Directive, it’s necessary to read carefully the “Safety Manual” (chapter 10).In case the sensors are used for applications in potentially explosive atmospheres, please read carefully (chapter 12).Installation and maintenance must only be carried out by suitably skilled and qualified personnel.The following acronyms are frequently used:BFSL Best Fit Straight LineDD Device DescriptorEEPROM Electrically Erasable Programmable Read Only MemoryFS Full Scale OutputHART Highway Addressable Remote TransducerLRV Lower Range ValuePT Pressure TransmitterPV Primary Variable (Pressure)RTD Resistance Temperature Detector (A very accurate temperature sensor)SV Secondary Variable (Electronics Temperature)TV Tertiary Variable (Snout Temperature)URV Upper Range ValueWatchdog An internal timing control for the electronicsHWE Hart Oil Filled Melt Pressure TransducerHWX Hart Oil Filled Melt Pressure Transducer Ex CertifiedHWE P Hart Oil Filled Melt Pressure Transducer PL d CertifiedHWX P Hart Oil Filled Melt Pressure Transducer Ex and PL d CertifiedHWE S Hart Oil Filled Melt Pressure Transducer SIL 2 CertifedHWX S Hart Oil Filled Melt Pressure Transducer Ex and SIL 2 CertifedHME Hart Mercury Filled Melt Pressure TransducerHMX Hart Mercury Filled Melt Pressure Transducer Ex CertifiedHME P Hart Mercury Filled Melt Pressure Transducer PL d CertifiedHMX P Hart Mercury Filled Melt Pressure Transducer Ex and PL d CertifiedHME S Hart Mercury Filled Melt Pressure Transducer SIL 2 CertifedHMX S Hart Mercury Filled Melt Pressure Transducer Ex and SIL 2 CertifedHKE Hart NaK Filled Melt Pressure TransducerHKE P Hart NaK Filled Melt Pressure Transducer PL d CertifiedHKE S Hart NaK Filled Melt Pressure Transducer SIL 2 CertifedGefran Melt sensors are pressure/temperature transmitters designed for use in high temperature envi-ronments. They read media pressure up to a temperature of 538°C, and resist such high temperatures thanks to their special mechanical construction, in which the measurement element is isolated from the Melt.The constructive principle is based on hydraulic transmission of pressure; mechanical strain is transferred by means of a non-compressible transmission liquid.The liquid used in these sensors may be mercury (i.e. HM series), FDA-approved oil (i.e. HW series) or NaK (i.e. HK series). Strain gauge technology translates the physical quantity (pressure) into an electrical signal. Four different designs are available: rigid rod, flexible sheathing, flexible plus thermocouple, and exposed tip. Gefran Melt sensors satisfy all installation and field requirements.The sensors can read an extremely wide range of pressures: from a version with minimum range of 0-17 bar up to a version with a scale of 0-2000 bar.All models in the catalog can be supplied in two different classes of accuracy*: class M, with accuracy of 0.5% FS, and class H, with accuracy of 0.25% FS. Ex and Performance Level ‘d’ or SIL2 certified versions are available.* For HMX/HWX products sold to EAC Customs Union (EAC mark), due to a different method of calculation, the limits of accuracy are the following:_M = 1%_H = 0,5%For all the other details and technical features please keep as reference the product datasheets or Gefran website .4.1 HWE – Technical dataAccuracy (1) H <±0.25%FS (100...1000 bar)M <±0.5%FS (17...1000 bar) Resolution16 bitMeasurement range0..17 to ... 0..1000bar0..250 to 0..15000psi Rangeability3:1Maximum overpressure (without degrading performances) 2 x FS1.5 x FS above 500bar/7500psi Measurement principle ExtensimetricPower supply13...30VdcMaximum current absorption23mA (40mA with relay optional) Output signal Full Scale (FS)20mAZero balance (tollerance ± 0.25% FS)4mACalibration signal80% FSPower supply polarity reverse protection YesCompensed temperature range housing0...+85°COperating temperature range housing-30...+85°CStorage temperature range housing-40...+125°CThermal drift in compesated range: Zero / Calibration / Sensibility< 0.02% FS/°C Diaphragm maximum temperature315°C / 600°FZero drift due to change in process temperature (zero)< 0.04 bar/°CStandard material in contact with process medium Diaphragm:• 17-7 PH corrugated diaphragm with GTP+ coating Stem:• 17-4 PHThermocouple (model HWE2)STD: type “J” (isolated junction) Protection degree (with 6-pole female connector)IP65Electomagnetic compatibility – Emissions EN 61326-1 EN 61326-2-3 EN 61326-3-1Electomagnetic compatibility – Immunity EN 61326-1 EN 61326-2-3 EN 61326-3-1FS = Full scale output(1) BFSL method (Best Fit Straight Line): includes combined effects of Non-Linearity, Hysteresis and Repeatability.For products sold to EAC Customs Union (EAC mark), due to a different method of calculation, the limits of accuracy are the following: _M = +-1%_H = +-0,5%4.2 - HME – Technical dataAccuracy (1) H <±0.25%FS (100...2000 bar)M <±0.5%FS (17...2000 bar) Resolution16 bitMeasurement range0..17 to 0..2000bar0..250 to 0..30000psi Rangeability3:1Maximum overpressure (without degrading performances) 2 x FS1.5 x FS above 1000bar/15000psi Measurement principle ExtensimetricPower supply13...30VdcMaximum current absorption23mA (40mA with relay optional) Output signal Full Scale (FS)20mAZero balance (tollerance ± 0.25% FS)4mACalibration signal80% FSPower supply polarity reverse protection YesCompensed temperature range housing0...+85°COperating temperature range housing-30...+85°CStorage temperature range housing-40...+125°CThermal drift in compesated range: Zero / Calibration / Sensibility< 0.02% FS/°C Diaphragm maximum temperature400°C / 750°FZero drift due to change in process temperature (zero)< 0.02 bar/°CStandard material in contact with process medium Diaphragm:• 15-5 PH with GTP+ coating• 17-7 PH corrugated diaphragm with GTP+ coating for ranges <100 bar (1500psi)Stem:• 17-4 PHThermocouple (model HME2)STD: type “J” (isolated junction) Protection degree (with 6-pole female connector)IP65Electomagnetic compatibility – Emissions EN 61326-1 EN 61326-2-3 EN 61326-3-1Electomagnetic compatibility – Immunity EN 61326-1 EN 61326-2-3 EN 61326-3-1FS = Full scale output(1) BFSL method (Best Fit Straight Line): includes combined effects of Non-Linearity, Hysteresis and Repeatability.Sense resistor Load Line250 ohm minimum for HART communicationSensors are manufactured in compliance with: - EMC compatibility directive - RoHS directive - Machinery directiveElectrical installation requirements and Conformity certificate are available on our web site: 100200300400500600700800900R ( Ω)Vcc (V)WORKING AREA4.4 - HWX – Technical dataAccuracy (1) H <±0.25%FS (100...1000 bar) M <±0.5%FS (17...1000 bar)Resolution16 bitMeasurement range 0..17 to 0..1000bar 0..250 to 0..15000psi Rangeability3:1Maximum overpressure (without degrading performances) 2 x FS1.5 x FS above 500bar/7500psi Measurement principle Extensimetric Power supply13...30Vdc Maximum current absorption23mAOutput signal Full Scale (FS)20mA Zero balance (tollerance ± 0.25% FS)4mA Calibration signal80% FS Power supply polarity reverse protection YesCompensed temperature range housing 0...+85°C Operating temperature range housing -30...+85°C Storage temperature range housing-40...+125°C Thermal drift in compesated range: Zero / Calibration / Sensibility < 0.02% FS/°C Diaphragm maximum temperature315°C / 600°F Zero drift due to change in process temperature (zero)< 0.04 bar/°C Standard material in contact with process medium Diaphragm:• 17-7 PH corrugated diaphragm with GTP+ coating Stem:• 17-4 PHThermocouple (model HWX2)STD: type “J” (isolated junction)Protection degree (with 6-pole female connector)IP65Electomagnetic compatibility – EmissionsEN 61326-1EN 61326-2-3EN 61326-3-1Electomagnetic compatibility – ImmunityEN 61326-1EN 61326-2-3EN 61326-3-1FS = Full scale output(1) BFSL method (Best Fit Straight Line): includes combined effects of Non-Linearity, Hysteresis and Repeatability.Sense resistor Load Line250 ohm minimum for HART communicationSensors are manufactured in compliance with: - EMC compatibility directive - Machinery directive- Ex regulations (ref. par.12)Electrical installation requirements and Conformity certificate are available on our web site: 100200300400500600700800900R ( Ω)Vcc (V)WORKING AREA4.5 - HMX – Technical dataAccuracy (1) H <±0.25%FS (100...2000 bar) M <±0.5%FS (17...2000 bar)Resolution16 bitMeasurement range 0..17 to 0..2000bar 0..250 to 0..30000psi Rangeability3:1Maximum overpressure (without degrading performances) 2 x FS1.5 x FS above 1000bar/15000psi Measurement principle Extensimetric Power supply13...30Vdc Maximum current absorption23mAOutput signal Full Scale (FS)20mA Zero balance (tollerance ± 0.25% FS)4mA Calibration signal80% FS Power supply polarity reverse protection YesCompensed temperature range housing 0...+85°C Operating temperature range housing -30...+85°C Storage temperature range housing-40...+125°C Thermal drift in compesated range: Zero / Calibration / Sensibility < 0.02% FS/°C Diaphragm maximum temperature400°C / 750°F Zero drift due to change in process temperature (zero)< 0.02 bar/°C Standard material in contact with process mediumDiaphragm:• 15-5 PH with GTP+ coating• 17-7 PH corrugated diaphragm with GTP+ coating for ranges <100 bar (1500psi)Stem:• 17-4 PHThermocouple (model HMX2)STD: type “J” (isolated junction)Protection degree (with 6-pole female connector)IP65Electomagnetic compatibility – EmissionsEN 61326-1EN 61326-2-3EN 61326-3-1Electomagnetic compatibility – ImmunityEN 61326-1EN 61326-2-3EN 61326-3-1FS = Full scale output(1) BFSL method (Best Fit Straight Line): includes combined effects of Non-Linearity, Hysteresis and Repeatability.Sense resistor Load Line250 ohm minimum for HART communicationSensors are manufactured in compliance with: - EMC compatibility directive - Machinery directive- Ex regulations (ref. par.12)Electrical installation requirements and Conformity certificate are available on our web site: 100200300400500600700800900R ( Ω)Vcc (V)WORKING AREAFor the mechanical dimensions please keep as reference the product datasheets or Gefran website TECHNICAL DATAExtrusion processes require very high temperatures. Extrusion pressure can be checked by means of espe-cially designed transducers. Thanks to their special mechanical construction, in which the measurement ele-ment is isolated from the Melt, they resist to such high temperatures. The constructive principle is based on hydraulic of pressure; mechanical strain is transferred by means of a non-compressible transmission liquid. Strain gauge technology translates the physical quantity (pressure) into an electrical signal.Following advice for extending the sensors lifetime.a) Avoid shocks and abrasions to the in contact diaphragm. Protect the transducer with its cover each time you remove it from its seat.b) The seat must be prepared perfectly and with appropriate tools in order to respect the depth and axiality of the holes and tapping.Pay particular attention to the coaxiality of the holes to the thread, because diaxialities greater than 0.2 mm will break the transducer during assembly. It is essential that hole depth guarantees the absence of chambers or air pockets in which extrusion material may be trapped.To prevent contact with the extrusion screw or with tools used to clean the extrusion chamber, the front diaphragm must not extend from the inner wall of the extruder.c) Before assembling the transducer in machines already in operation, make sure that the housing is clean. Remove any residual with the suitable cleaning device.d) The transducer should be removed only with the machine empty (without pressure) but still hot.e) The transducer should be cleaned with solvents for the material being processed.Any mechanical action on the contact diaphragm modifies its operation and could break it.6.1 - Installation seatThe installation seat has to be realized:Drilling kitA drilling kit with formed tools for drilling, reaming and tapping is available to facilitate correct preparation of the assembly seat. The assembly seat must be perfect to assure proper transducer function and long lifetime. Drilling kits are available in the following versions: KF12, KF18.Drilling procedure1) To drill hole (D4) up to a distance from the hole equal to the sum of (A+B+C) (tool 3).2) Make the pass through hole (D2) by the tool 1.3) To create the seal seat at a distance from the hole equal to dimension (A) (tool 4).4) With a roughing tap, create threading 1/2-20UNF-2B (recognizable from the greater number of threads beveled at the mouth) (tool 5).5) With a finishing tap, go over threading 1/2-20UNF-2B up to a distance from the bottom equal to the sum of (A+B) (tool 6).6) To ream the hole (D2) with reamer (tool 2).Installation seat checkThe dimensions of the assembly seat have to be checked after preparation and before the transducer installation.Use dummy plug SC 12/18 as follows:1) Coat the end of the rod with the appropriate ink.2) Lubricate the threaded part to prevent friction.3) Insert the dummy plug and screw it fully down.4) Remove the rod and examine it.With the exception of 45° surfaces, the ink should be intact on the entire surface .6�2 DRILLING TOOL KITCORRECT INSTALLATIONWRONGWRONGWRONGCORRECTVERSION CODE KF12KF18THREADING TYPE 1/2-20UNF-2BM18x1.51Ø 7.6Ø 9.752Ø 7.95Ø 10.13Ø 13Ø 204Ø 11.5 with pilot guideØ 16 with pilot guide51/2-20UNF-2Broughing M18x1.5roughing61/2-20UNF-2Bfinishing M18x1.5finishingIncorrect working or shape of the side can result in properties out of specification, bad behaviour or damage to the sensor.The side should be clean and without any polymer residual.contact surfaceTRANSDUCER INSTALLATIONInstallation procedure1) Make sure the drilling procedure has been realized correctly. If the sensor is installed in a previously used hole, make sure the hole is completely clean and free of any plastic residual.2) Remove the protective cap from the sensor tip.3) Lubrificate the thread with non-grip grease such as Neverseez (Bostik), or C5A (Felpro), or equivalent.4) Insert firmly the sensor into the hole, first by hand and then with a wrench, 1/4 turn at a time.Recommended torque: 50 Nm, the maximum is 56.5 Nm.Removal (Figure 1)To remove the transducer from its seat and carry on the working process, dummy plugs with identical mecha-nical dimensions are available.The dummy plugs differ by type of threading; max pressure range is 2000 bar for all rods.The dummy plugs are available in the following versions: SC12 1/2-20UNF seat - SC18 M18x1,5 seat.Brackets (Figure 2)Models with flexible sheaths require the housing precise fixing. Suitable fastening brackets (SF18) are recom-mended.Remember that the fastening point must be vibration-free (vibrations affect the measurement) and that tem-peratures must not exceed the maximum temperature range for the strain gauge housing (as stated on the sensor technical sheet).Extruder startingBring the system to working temperature with the transducer installed and without any pressure applied. Wait until all the material is at the same temperature to prevent the transducer damage by semi-solid material.Seat cleaning & Cleaning toolAs mentioned in the notes, the seat must be cleaned before the transducer installation.The cleaning tool is a hard metal cutting tool specially designed to remove working materials residuals.Recommended procedure (Figure 3)The following procedure must be implemented with the material in a fluid condition.1) Insert the tool in the seat and screw down the cutting rod (normally a 1/4 turn at a time).2) Turn the pilot cutter clockwise until there is no resistance to cutting.3) Repeat the procedure until the seat is completely clean.For constructive reasons, the maximum torque applicable to the cutter is 15 Nm (1.5 Kgm).If the hole occlusion requires higher torque for removal, use the drilling kit and follow the recommended procedure.The cleaning tool is available in the following versions: CT12 1/2-20UNF seat - CT18 M18x1,5 seat.Figure 1Figure 3Figure 26�3 - Wiring and calibrationConnectionsThe sensors have to be connected as shown in the diagram at chapter 7.To obtain a higher immunity from field noise, connect the cable shield to the female connector case on sen-sor side.Calibration procedure using the magnetic pen/Pin CALBring the system to the working temperature with the transmitter installed and connected to the measure-ment instrument without any pressure applied.The measurement chain connected to the transmitter is calibrated as follows:1) To reset the offset on the instrument by eliminating the thermal drift with the autozero function.With the sensor installed and the extruder at working temperature, wait until the temperature itself is stable, with a possible variation of ± 1°C. Consequently Autozero can be activated. This allows to compensate all the signal drifts caused by tightening and temperature.Additional Autozero activations could be run once the temperature stability is reached, with ± 1°C of possible variation.2) Calibrate the instrument activating the CAL function. The transducer brings its output to the calibration value shown on the transducer data plate (80% of full scale default, if changed with HART command it could be different).With the external Autozero function the calibration procedure is not feasible.3) If the instrument does not exactly indicate zero, repeat points 1) and 2).In this way, the instrument is calibrated to give the exact indication in the chosen engineering unit.Calibration procedure using HART communicationBring the system to the working temperature with the transmitter installed and connected to the measure-ment instrument without any pressure applied.1) Connect Communicator to the loop. In case it’s not sure on how to do this, please refer to “Connecting the HART Handheld Communicator” (Fig. 8.1).2) Switch on HART Communicator. Please refer to HART Command tree on Ready-to-Use guide.3) From the Main Menu:a. Enter Tag (Fast Key 1, 3, 1)b. Set Pressure Units (Fast Key 1, 3, 3), if neededc. Set URV (Fast Key 1, 3, 4) if output turndown (rescaling), is neededd. Perform Autozero (Fast Key 1, 2, 6, 3, 1)4) Check loop output is zero (4mA).5) Remove HART Communicator from loop.ORDER CODES FOR TOOLS and ACCESSORIESThe interface to controller can be:- the multi-polar connector type VEAM VP07RA10-6PT2 (code GEFRAN CON301),- the multi-polar connector type BENDIX PC02E-12-8P 8 poles (code GEFRAN CON356)- the multi-polar cable outlet with conduit output type ½ 14-NPT as illustrated in fig 7.1.where are also pointed out the connections (2 wires connection current amplified). In the case of relay output with retransmitted output in current (2 wires) the connections are shown in fig. 7.2.CURRENT OUTPUT (NO RELAY)The cable shield is tied to both sides, i.e. to the sensor connector and to the controllerFig 7.1RELAY OUTPUTThe cable shield is tied to both sides, i.e. to the sensor connector and to the controllerFig 7.2。
BK使用说明书详解

使用说明书JW-BK系列静态容量法比表面及孔径分析仪目录1.原理及方法1.1氮吸附比表面测定方法1.2静态容量法2.仪器结构与安装2.1机型及配置2.2 结构2.3硬件安装2.4软件安装3.测试界面功能详细说明3.1文件(F)3.2设置(C)3.3操作(D)3.4查看(V)3.5窗口(W)3.6帮助(H)3.7新建3.8打开3.9保存3.10设置界面的显示效果3.11设置系统固定参数3.12设置吸附、脱附参考压力3.13开始吸附3.14终止吸附3.15开始脱附3.16终止脱附3.17数据预览3.18打印3.19关于3.20阀门控制3.21予抽3.22充气3.23升降控制3.24当前气压3.25实验开始和终止时间3.26页面上实验过程的实时显示4.实验程序4.1装样和称样4.2样品管安装4.3予抽4.4预处理4.5样品条件与仪器参数设定4.6存储路径设定4.7实验项目及压力设定4.8液氮杯及密封4.9开始试验4.10实验过程实时显示4.11实验数据预览4.12实验结束4.13重量复核4.14数据保存4.15实验结果及测试报告4.16打印5. 真密度测试6.BK系列不同产品的若干差异6.1预处理位置及操作方法6.2传感器类型及显示方法6.3压力设置及平衡时间的控制方法6.4具有微孔分析功能的产品6.5双样品测试6.6多工作站7.影响测试结果的因素7.1样品本身因素7.2预处理的充分与否7.3样品称样量及精度7.4真空度7.5真空泄漏7.6温度7.7气压7.8液氮纯度7.9液氮杯的密封7.10温度延时7.11样品管的位置7.12测试条件的选择8.仪器维护及常见故排除8.1 真空系统维护8.2 充气速度调整8.3 防止样品抽飞8.4真空抽不上8.5真空阀门不密封8.6管路的污染8.7预处理系统结构与故障9.安全注意事项10.微孔测试10.1微孔测试程序10.2吸附泵的应用10.3微孔测试报告【附录1 】物理模型及分析方法使用说明书简单说明:本说明书是针对JW-BK系列比表面及孔径分析仪而编写的,该系列的仪器是采用低温氮吸附和静态容量法的原理设计的,这是国际上通用的方法,与美国康塔公司、麦克公司生产的比表面及孔隙度仪在原理和功能上都是相同的,但是在具体的结构与操作与软件细节上,各有特点,本使用说明书对本机尽量做详尽的说明,目的是帮助用户用好仪器,知其然并知其所以然,为提高中国仪器的技术水平和使用水平做出努力。
柯力 KH系列 数显式推拉力计 使用说明书

KH系列数显式推拉力计柯力中文使用说明书2011年11月版宁波柯力传感科技股份有限公司●使用前请仔细阅读本产品说明书●请妥善保管本产品说明书,以备查阅目录KH系列规格参数 (1)KH系列推拉力计外形结构 (2)KH系列外形尺寸 (3)安全注意事项 (4)使用提示 (5)功能 (5)主要特点 (6)规格参数 (6)各部件的名称与功能 (6)一液晶显示窗 (7)二功能按键 (8)参数设定方法 (10)中英文提示选择、显示翻转及置零范围设置方法 (14)上下限自动报警指示灯 (15)充电指示 (15)通讯接口 (15)充电器插孔 (15)打印接口 (16)使用前准备 (16)校准 (16)测试 (20)1开/关机 (20)2清零 (20)3选择测试模式 (20)4选择计量单位 (21)5测试 (21)数据的存储打印 (22)查看与删除永久记忆区 (23)串口引脚说明: (24)传感器外置式接口说明 (24)包装与附件 (25)保养及维护 (25)2008年5月版KH系列推拉力计外形结构KH系列外形尺寸安全注意事项1使用前请详细阅读本说明书,错误的操作有可能会损坏本机或发生严重事故。
2在做破坏试验时,应做好防护工作。
3试验前要详细检查安装夹具,请勿使用损坏或弯曲变形的夹具。
4传感器负荷超出额定负荷的110%时显示屏会提示警告信息,此时应立刻减小负荷,避免损坏传感器。
开机时请不要加载额定负荷的10%。
使用提示1不要用尖锐的工具代替手指按键操作。
2本仪器只能用于测试推力或拉力,不要让测试杆承受弯曲或回旋方向力。
3合理选择推拉力计的量程,如果是测试冲击载荷,要选用比冲击载荷至少大一倍的量程。
4请勿在水、油或其他液体溅到的地方使用推拉力计,要将推拉力计存放在阴凉干燥、无振动的地方。
5请使用配套的充电器充电,绿灯亮时电池已充满,使用中可以同时进行充电,正常的充电大约需4小时。
6仪表内置6V/1500mAh镍氢充电电池,不要使用其他种类的电池。
香港香港阀门配件有限公司阀门配件说明书

SHOWA 补偿器金属软接头目 录科目目录 ................................................................................................ 金属软接头..................................................................................EXF 110 .......................................................................................... EXF 115 .......................................................................................... EXF 122 .......................................................................................... EXS 210 .......................................................................................... EXS 255 .......................................................................................... 补偿器.........................................................................................EXDZ .............................................................................................. EXFZ .............................................................................................. EXWZ ............................................................................................. 软管和软网的尺寸及性能................................................................... 有变位时软管长度计算...................................................................... 正确的安装方式................................................................................ 法兰连接尺寸................................................................................... 单位换算表...................................................................................... 资料 不锈钢耐腐蚀表........................................................................ 软管产品选型、安装及实用注意事项.................................................... 0102-06020304050607-1207091113151819222328页码具有优异耐弯曲性能的焊接组装法兰连接形式。
新型海地1211 H100 商品介绍说明书

Always Ready fora real jungle out there: To survive in today’s business world, it helps to have maximum flexibility and versatility. And that’s precisely the competitive advantage of owning and operating the new H100. The new H100 is now available in a variety of different models tailored to your specific requirements. For example, the special Low Deck edition is designed especially for the easier loading and unloading of cargo. The Low Deck is available in a choice of two different wheelbases: long and extra-long. Others may find greater efficiency in the High Deck edition which is available in the long wheelbase edition only. Your Hyundai salesman will be happy to explain the specific features.
Designed for Life on the Road
Life on the road can be tough at times. Nobody knows that better than truck drivers. Which is why the new, quieter and more comfortable H100 is such good news. It really does make driving a lot easier on the body and mind. For starters, the new H100 gives you an extra-roomy cabin that is now quieter than ever. And then there’s the ergonomically designed seats which deliver perfect support – right where it matters most. The multi-density foam specified for the seat cushion and backrest does a lot to ease the stresses and strains of driving all day long. The optional tilt-adjustable steering wheel helps ensure the perfect driving position while the centre console and instrument cluster are perfectly intuitive to understand and operate.
海南曼姆全系产品介绍说明书

Heinemann®GJ1P Series Circuit BreakersDESCRIPTIONOptional Low-Voltage Shunt for Current MeteringEaton Corporation’s Cutler-Hammer series of Heinemann GJ1P breakers offer high quality circuit protection for DC applications from 100 to 1200 Amperes.Their precisely tailored time delays and ability to interrupt high currents makes them ideally suited for critical applications. On overloads exceeding 1000 – 1400% of rating, there is no intentional time delay and the breaker interrupts currents of as much as 25,000 A at 65V DC.An optional shunt (25 or 50millivolt full scale) permits metering of current. Since the shunt output is low voltage,light-gauge wiring can be used from shunt to meter.Indication may be displayed inpercent, watts, safe/danger or other dial calibrations. In addition, the busbar is available in two versions:Standard Size and Reduced Size. Contact your Eaton Sales Representative for more information.Precision Current Equalization (PCE) Circuit BreakersGJ1P breakers rated 250 to1200 A are built in parallel construction. Conventional parallel pole breakers can experience uneven current distribution because of variations in internalresistances. This condition can result in nuisance tripping since the higher current in one parallel branch has the same effect as an overload on the sensing element in that branch. Proprietary Precision Current Equalization (PCE)circuit breakers, on the other hand, allow for differences in internal resistances byautomatically distributing the current equally through the parallel current sensing elements, minimizing the danger of nuisance tripping.The UL listed series GJ1P (UL489) models are available in a choice of fast, medium or slow response times to accurately match load conditions. They can be ordered in “series trip ”, “mid-trip ” and “switch only ”constructions and are available front- or back-mounted, front- or back-connected, with optional auxiliary switches for signaling.HYDRAULIC-MAGNETIC BENEFITSThe magnetic/hydraulic load-sensing and time delaymechanisms used in GJ1P breakers are insensitive to changes in ambient or enclosure temperature.Therefore, GJ1P circuitbreakers are suited for service conditions encountered in telecommunications,transportation, air conditioning and other outdoor or “heat-loaded ” equipment.SPECIFICATIONSStandard Current Ratings:100, 125, 150, 175, 200, 225,250, 300, 350, 400, 450, 500,600, 700, 800, 900, 1000,1100, 1200 A.Standard Maximum Voltages:160V DC up to 700A65V DC from 701 to 1200A Breakers will be labeled with standard maximum (UL) voltage unless otherwise specified.Special Current Ratings:Any integral rating between 100and 1200 A DC. Consult factory for ordering information and metering shunt restrictions.Interrupting Capacities:UL Listed:10,000 A @ 160V DC 25,000 A @ 65V DC Non-UL:14,000 A @ 160V DC.Operating Temperature Range:-40°C to +85°C.Approximate Weight:1-pole (100-225A) 1.13kg (2.5lbs)2-pole (250-400A) 2.27kg (5lbs)3-pole (450-700A) 3.40kg (7.5lbs)4-pole (701-800A) 4.54kg (10lbs)5-pole (801-1000A) 5.67kg (12.5lbs)6-pole (1001-1200A) 6.80kg (15lbs)Weight may vary based on shunt and busbar.APPROVALSUL Listing:GJ1P breakers are UL listed per UL489. For CSA certification,consult application engineering.Description . . . . . . . . . . . . . .2Specifications . . . . . . . . . . . .2Approvals . . . . . . . . . . . . . . .2Time Delay Characteristics . . .3Dimensions . . . . . . . . . . . .4-5How to Order . . . . . . . . . . .6-7Additional Products. . . . . . . . .8TABLE OF CONTENTS PageHEINEMANN ®CIRCUIT BREAKERSGJ1P Series Circuit Breakers(100-1200 Amperes DC)2Heinemann is a registered trademark of the Eaton Corporation, Commercial Controls Business Unit.100150.01.001.1110100100010,000200300400500600700800900100011001200125C u rv e 1C u rv e 2C u rv e 3Current – Percent of Ampere RatingT r i p T i m e – S e c o n d sDC CURVES100150.01.001.1110100100010,000200300400500600700800900100011001200125Current – Percent of Ampere RatingT r i p T i m e – S e c o n d sINSTANT DELAY DC CURVE PPERCENT OF RATED CURRENT VS. TRIP DELAY AT 25ºCTIME DELAYCHARACTERISTICSTime delay, in all models,is inversely proportional to the magnitude of the overload, adjusting automatically to limit transient power to the load. On overloads exceeding 1,000 –1,400%, the circuit breaker trips without any deliberately imposed delay.Curve 1.Standard time delayis furnished unlessanother optional delay is specified. It is thepreferred characteristic for use where the load is composed of both resistive and inductive components.Curve 2.Medium time delayis for general usein mixed (inductive and resistive) circuits where the breaker rating is matched to the current carrying capacity of the mains.Curve 3.Short time delaypermits a very brief delay period before tripping.Curve P .Non-time delay breakersare available forapplications which cannot tolerate even brief transient overloads.These breakers have no time delay mechanism other than that imposed by the coil self-inductance and the inertia of the mechanism.Tripping specificationsThe time delay curves depict breaker response time vs. percent of rated load with no preloading.The function is plotted at an ambient temperature of 77°F (25°C) with the breaker in a vertical or wall-mounted position.Series GJ1P circuitbreakers will carry 100%of rated load continuously.Both time delay and non-time delay breakers may trip between 101%and 125% of rated load,and must trip at 125%and above.3% (sec)Delay 100%125%200%400%600%800%1000%Delay Max.1no trip 1100150206 1.7.065Delay Min.1no trip 110224 1.1.01.008Delay Max.2no trip 110153.8.28.055Delay Min.2no trip 12 2.5.5.18.01.008Delay Max.3no trip 10.8.19.08.047.038Delay Min.3no trip.44.13.03.015.01.008STANDARD FRONT-CONNECTED CONSTRUCTIONWire Range #6 to 250 MCM74.59(2.938)76.20(3.000)Aux. Terminals, Male Type Molex 02-09-2101, Model 1190-T(See Illustrations for Combinations)Shunt Terminals, Female TypeMolex 02-09-1101, Model 1189-T37.69(1.484)42.84(1.687)0.99 (0.390)71.42(2.812)#10-32 Inserts (4 Places)38.10(1.500)19.05(0.750)19.05(0.750)6.35 ± 0.38(0.250 ± 0.156)6.35 ± 0.38(0.250 ± 0.156)Panel Mounting Hole Distance for #10-32LINELOAD 75.38(2.968)5.53(0.218)59.91(2.359)32.13(1.266)5.53(0.219)“D ” Type Terminals as Shown180.97(7.125)41.27(1.625)4.74(0.188)58.67(2.313)41.27(1.625)41.27(1.625)263.52(10.375)29.36(1.156)7.14(0.281)78.56(3.094)59.13(2.328)28°±5°32°±5°ONOFFSee Optional Terminal ConfigurationWire Range #6to 250 MCM41.27(1.625)36.49(1.437)38.10(1.500)100 – 22 A250 – 400Width dimensions are as follows:100 – 225 38.1 (1.5)250 – 400 A 76.2 (3.0)450 – 700 A 114.3 (4.5)701 – 800A 142.4 (6.0)801 – 1000A 190.5 (7.5)1001 – 1200A228.6 (9.0)28.95(1.141)46.40(1.828)22.22(0.875)Fastener Mounted ThisSide of Bus Plate,Terminals are Front-Connected and Unit is Rear-Mounted.Fastener Mounted This Side of Bus Plate, Terminalsare Back-Connected and Unit is Panel-Mounted.60.32(2.375)7.92(0.312)3/8-16UNC -2B (4 per Unit)38.10(1.500)225.43 (8.875)Center to CenterOptional Terminal ConfigurationsHEINEMANN ®CIRCUIT BREAKERSGJ1P Series Circuit BreakersDIMENSIONSDimensions are given here only as a preliminary guide to specifying. Final engineeringdrawings should be made from the latest Heinemann drawings. Contact Customer Service Center.Tolerance:±0.79 (0.031) except where noted. For metric threads, contact Customer Service Center.DIMENSIONS APPROXIMATE IN MM (INCHES)431.75(1.250) Min.41.65(1.641) Max.19.05(0.750)7.51(0.297)7.51(0.297)7.51(0.297)16.66(0.656)Typ.29.36(1.156)29.36(1.156)48.41(1.906)48.41(1.906)67.46(2.656)67.46(2.656)38.10(1.500)38.10(1.500)38.10(1.500)38.10(1.500)19.05(0.750)19.05(0.750)19.05(0.750)22.23(0.875) Min.321.31(12.65) Max.78.96(3.109)Min. Typ.5.15(0.203)Dia. Typ.C100 – 225 A Ratings 226 – 400 A Ratings401 – 700 150A RatingsBA106.75(4.203)Typ.C LC L C L FRONT MOUNTING PANEL AND SUPPORT BRACKET115.08(4.531)76.98(3.031)38.1(1.500)38.1(1.500)71.42(2.912)5.94(0.234)Ref.5.15(0.203)Typ. Dia.65.02(2.562)59.13(2.328)(3-Pole)3PoleC L C L C L Holes Required When Breaker Is Front-Mounted2Pole1PoleAB C (2-Pole)(1-Pole)38.88(1.531)19.43(0.765)Mounting kits containing clips, brackets and necessary hardware and instructions are available (consult factory).009-18234 100 – 225 A 1.5 (1-pole wide)009-18235 250 – 400 A 3 (2-pole wide)009-18232 450 – 700 A 4.5 (3-pole wide)For 701-1200A devices, contact your Eaton Sales Representative for mounting kit part numbers.See Step (2)See Step (5)BACK MOUNTING CIRCUIT BREAKERBack mounting circuit breaker mounting instructions 1. Position circuit breaker to support brackets.2. Place mounting bracket in recess on front top portion of circuit breaker.3. Install four (4) #10-32 by 3-1/4" long screws through holes in mounting bracket and support structure.4. Install lock washer and nut on each of the screws and tighten.5. Place mounting bracket on front lower portion of circuit breaker.6. Install two (2) #10-32 by 5/8" screws through holes in mounting bracket and support structure.7. Repeat step 4.5DIMENSIONS APPROXIMATE IN MM (INCHES)NOTE: Standard size busbar is shown above. For the reduced size busbar, contact your Eaton Sales Representative for mounting dimensions.Series PrefixGJ1PSwitch (No Coil)Series Trip w/SPDT Aux. SwitchSeries Trip Series Trip and Mid-Trip Series Trip, Mid-Trip and SPST Alarm SwitchTerminal Location Back FrontInternal Circuit Metering ShuntNo Shunts Metering Shunt Metering ShuntB HCodeLocationInternal CircuitCodeDescriptionShuntCode—25mV 50mVP M N0-2-3-98-99-Series Prefix GJ1PTerminal LocationBInternal Circuit3-Metering ShuntPAdd each appropriate Number or Letter …HEINEMANN ®CIRCUIT BREAKERSGJ1P Series Circuit BreakersHOW TO ORDER — Series GJ1PTo determine your Complete Catalog Number , you must start with appropriate Series Prefix and add the appropriate Code Letters and/or Numbers as in the example below:SELECTION TABLE61Multi-pole construction – Consult factory.An auxiliary switch, if supplied, will be located in the right pole space. If the auxiliary switch is supplied in a breaker which has a metering shunt, it will be single-pole single throw (SPST). The single-pole double throw (SPDT) auxiliary switch can be supplied only in a breaker without a metering shunt.2Cannot be used on breaker containing metering shunt.3Only for breakers rated in excess of 250 A. Breakers up to 250 A without meteringshunt are available as standard GJ1 type breakers. Please consult Series GJ catalog.MarketUL-489TerminalsSolderless Connector Bus Bar ConnectionStandard Current Ratings 1AmpereTrip Curve 1123P0 – 1200(Add 0 before amp rating if less than 1000A.Example: 0700)-01-02-03-0PDescriptionCodeDEDUStandardCodeCurveCodeComplete Catalog Number: GJ1PB3-PEDU0700-02Terminal ConfigurationEUS/European ApprovalDUStandard Current Ratings 10700Trip Curves 1-024Add 0 before amp rating if less than 1000. For example: a 700A rating would bedesignated as 0700.The width of the breaker is determined by the current rating:100 – 225 A 1.5” (1-pole wide)250 – 400 A 3” (2-pole wide)450 – 700 A 4.5” (3-pole wide)701 – 800A 6” (4-pole wide)801 – 1000A 7.5” (5-pole wide)1001 – 1200A 9” (6-pole wide)5See page 3 for time delay characteristics and trip curve information.7© 2001 Eaton Corporation All Rights Reserved Printed in USAForm No. BR5401SE0002A / CSS 65322June 2001Commercial ControlsFor the Widest Selection of Circuit Protection, from 0.01 to 1200 Amperes, Look to Eaton.。
哈凯产品有限公司产品说明书

T9-I.T9-L1.T9-2LFrom...American Hakko Products, Inc.28920 N. Avenue Williams.Valencia, CA 91355 Tel: (661) 294-0090 Fax: (661) 294-0096 AHP14 Rev 2000-01For pricing information, please contact your local American Hakko representative or our customer service department at (661) 294-0090.American Hakko Products, Inc.P R O D U C T B U L L E T I NBulletin No: PB260Issue Date: November 5, 2007 Product:FM-203 Dual Port Soldering StationPart No:FM203-01 FM203-DPComments:The Hakko FM-203 is a Dual Port high performance soldering station. Even when soldering lead-free solders the high performance allows loweroperating temperatures. The soldering station can operate any of the following hand pieces, FM-2027 Soldering Iron, FM-2022 Parallel Remover (SMD tweezer), FM-2023 Mini Parallel Remover (SMD mini tweezer), FM-2024 Desoldering Module, and/or FM-2026 Nitrogen Soldering Iron. The soldering iron and desolder tool can be used in either or both ports and the tweezers are limited to one port with a soldering or desoldering iron in the other port.The station features a programmable sleep mode of 0-29 minutes or auto-power shut off at 30 minutes. Sleep mode, auto power shut off and tip temperature can be programmed separately for each port. The sleep mode reduces the tip temperature to approximately 200ºC (400ºF) after the programmed time (0-29 minutes). The lower tip temperature will reduce oxidation of the tip and improve the tip performance. When in sleep mode the tip will quickly return to temperature after the iron is removed from the holder.When utilizing the FM-2027 Soldering Iron the station uses the T15 series composite tip. The composite tip is a soldering tip in which a heating element and sensor are integrated with ceramic. Despite its highly compact design, the tip offers superior thermal response and greatly improved thermal recovery. T15 series tips are available in a wide variety of tip shapes and can also be used with the Hakko FM-203, FP-102 and FM-202 soldering stations. Any tip can be operated at temperatures 200 - 450ºC (400 - 840ºF). The station includes a card lock system to lock the preset soldering temperature. With the card removed operators can not adjust the working temperature.The FM-2022 uses T16 tips, The FM-2023 uses T9 tips, The FM-2024 uses N3 nozzles and The FM-2026 uses T17 tips.Documentation Provided By HMC ElectronicsFrom...American Hakko Products, Inc.28920 N. Avenue Williams.Valencia, CA 91355 Tel: (661) 294-0090 Fax: (661) 294-0096 AHP14 Rev 2000-01Specifications:FM-203 Soldering Station Power Consumption 140W 120VTemperature Range 200 - 450ºC (400 - 840ºF) Temperature Stability ±5ºC (±9ºF) Temperature Accuracy±15ºC (±27ºF)Soldering Iron (No.FM-2027) Power Consumption 70W (24V) Tip to Ground Resistance < 2Ω Tip to Ground Potential < 2mV Cord Length1.2m (47 in.) Total Length (w/o Cord)with 2.4D soldering tip attached 188mm (7.4 in.) Weight (w/o Cord)with 2.4D soldering tip attached30g (1.0 oz.)StationOutput 24V Dimensions 120(W) x 120(H) x 190(D)mm (4.7 x 4.7 x 7.5 in.) Weight (w/o cord)2.7kg (5.9 lb.) Contents:Part No.NameFM203-01 FM203-DPN/AFM-203 soldering station1 1 FM2027-02 Connector 12B2387 Power cord 1 1 B2972 Control card 1 1 B3219 Sleeve assembly, Green, anti-bacterial 1 1 B3216 Sleeve assembly, Yellow, anti-bacterial 0 1 B2300 Heat-resistant pad 1 2 FH200-01Iron Holder, Sleep, w/ 599B12B3253 Connecting cable 1 2 B2756 Tip tray1 1 N/A Instruction manual1 1The FM2023-DP includes two FM-2027 connectors and sleep holders. Tips not included.Documentation Provided By HMC ElectronicsFrom...American Hakko Products, Inc.28920 N. Avenue Williams.Valencia, CA 91355 Tel: (661) 294-0090 Fax: (661) 294-0096 AHP14 Rev 2000-01Accessories/Replacement Parts:Part No. NameSpecificationFM2027-01 HAKKO FM-2027 w/ Yellow Sleeve Assembly Does not include tip or holder B3216 Sleeve Assembly Yellow (Lock-type, Antibacterial) B3217 Sleeve Assembly Orange (Lock-type, Antibacterial) B3218 Sleeve Assembly Blue (Lock-type, Antibacterial) B3219Sleeve Assembly Green (Lock-type, Antibacterial)A1536 Cleaning sponge GreenFM2022-05 Conversion kit FM-2022 Parallel Remover with sleep holder and cable. Tips not included. FM2023-05 Conversion kit FM-2023 Mini Parallel Remover with sleep holder and cable. Tips included. FM2024-21 Conversion kit/120 V FM-2024 Desoldering Module with sleep holder and cable. Nozzle not included. FM2026-06 Conversion kit FM-2026 Nitrogen Iron with sleep holder and cable. Tips not included.FM2027-03Conversion kitFM-2027 Soldering Iron with sleep holder and cable. Tips not included.Tips and Nozzles:See PB258 for T15 tip list for HAKKO FM-2027Tips for HAKKO FM-2022Part No. Part Name SpecificationsT16-1001 Tip / CHIP 0.5I T16-1002 Tip / CHIP 0.5C T16-1003 Tip / CHIP 1L T16-1004 Tip / CHIP 2L T16-1005 Tip / SOP 6L T16-1006 Tip / SOP 8L T16-1007 Tip / SOP 10L T16-1008 Tip / SOP 13L T16-1009 Tip / SOP 16L T16-1010 Tip / SOP 20L T16-1011 Tip / SOP 25L T16-1012 Tip / SOP 18L T16-1013Tip / CHIP 3LDocumentation Provided By HMC ElectronicsFrom...American Hakko Products, Inc.28920 N. Avenue Williams.Valencia, CA 91355 Tel: (661) 294-0090 Fax: (661) 294-0096 AHP14 Rev 2000-01Tips for HAKKO FM-2023Part No. Part Name SpecificationsT9-I Tip / CHIP I T9-L1 Tip / CHIP 1L T9-L2Tip / CHIP 2LNozzles for HAKKO FM-2024Part No. Part NameSpecificationsN3-06 Nozzle / 0.6mm (0.02 in.) N3-08 Nozzle / 0.8mm (0.03 in.) N3-10 Nozzle / 1.0mm (0.04 in.) N3-13 Nozzle / 1.3mm (0.05 in.) N3-16 Nozzle / 1.6mm (0.06 in.) N3-20 Nozzle / 2.0mm (0.08 in.) N3-23 Nozzle / 2.3mm (0.10 in.)N3-L10 Long Nozzle / 1.0mm (0.04 in.)Tips for HAKKO FM-2026Part No. Part NameSpecificationsT17-B2 SHAPE-0.5B Conical T17-BC1 SHAPE-1BC Bevel T17-BC2 SHAPE-2BC Bevel T17-BC3 SHAPE-3BC BevelT17-BCF1 SHAPE-1BC Bevel Tinned on the soldering surface onlyT17-BCF2 SHAPE-2BC Bevel Tinned on the soldering surface onlyT17-BCF3 SHAPE-3BC BevelTinned on the soldering surface only T17-BL SHAPE-B Long Shape Conical T17-D08 SHAPE-0.8D Chisel T17-D16 SHAPE-1.6D Chisel T17-D24 SHAPE-2.4D Chisel T17-J02 SHAPE-0.2J Bent T17-KF SHAPE-KF Knife T17-KR SHAPE-KR Knife T17-KUSHAPE-KU KnifeAvailable:November 6, 2007Documentation Provided By HMC ElectronicsT9-I.T9-L1.T9-2L。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
d) 在“界面3”中按“二级参数设定”进入密码保护界面“界面5”,按和输入密码,按“确认”键进入参数设定界面,若密码错误则显示“界面6”提示密码错误和重输密码、返回功能。
界面5界面6
e)若密码正确(系统默认密码是8888)则显示二级参数设定“界面7”,可对各个具体参数进行设定。首先选择要设定的闸门类型,按“确定”键即可。若所有要设定的二级参数都设定好了,可按“返回”返回到“界面3”。.
重量:2.5Kg
六.操作说明:
a)仪表通电后,屏幕显示系统默认的界面,如“界面1”所示。
界面1
b)按“切换”键,显示“界面2”。
界面2
c)按“确认”键,显示参数设置界面“界面3”.
界面3
在“界面3”中按“开度预置”进如开度预置界面“界面4”,按和可修改开度预置值,更改后按“确认”键返回“界面3”。在“界面3”中按“返回”键,界面切换到“界面1”或“界面2”。
二.产品特点
1.大屏幕液晶显示,中文汉字界面,内容清晰,操作方便。
2.高可靠的模块电源,24V直流电输入。
3.开度测量和荷重测量可以同时显示,显示内容全面。
4.采用工作电压监控和防止死机的看门狗技术。
5.采用高精度器件,采用数字滤波技术和误码检测技术,以提高测量准确性和可靠性。
6.通过面板上的按钮可完成各种数据设置操作,且有密码保护功能,防止误操作。
2.服务热线:电话:0551-5233325
传真:0551-5233326
a)开度:
(1).开度预置:闸门,开度预置灯亮,其对应继电器动作;
(2).实际开度:闸门此时的实际开度;
(3).开度上限灯:实际开度达到开度参数设定的上限时,灯亮;
(4).开度下限灯:实际开度达到开度参数设定的下限时,灯亮;
b)载荷:
(1).实际载荷1:载荷1的实际值,当实际值达到载荷1报警值90%时,荷载1的90%报警灯亮,达到110%时110%报警灯亮;
界面7
f) 按“切换”键,显示二级参数设定“界面8”。
界面8
在“界面8”中,首先选择“开度清零”,显示“界面9”,选择“确定”对开度进行清零。
界面9
再选定“开度设定”,显示“界面10”,
界面10
选择编码器正反转后,在显示“界面11”的状态下,将闸门关闭,再根据实际的要求设定编码器旋转一圈闸门开启的高度,按“确认”即可,返回到“界面8”。
界面15
界面16界面17
再选定“通讯地址”,显示“界面18”可对通讯地址进行设定。
界面18
任意参数都设定完成后,按“返回”可以返回到原始显示界面。
以上界面的选项功能均由箭头指示进行选择。
具体的操作说明框图则参见下图:
按下确认
按下确认
密码正确
选择类型
按下重输密码
按下返回
按下返回
按下确认
七.连线说明:
仪表后面板连线对照简图(后面正视图)
在数据采集的终端——传感器方面,开度信号采用了绝对光电编码器以SSI/RS422方式来工作,还可选用电流型编码器。载荷方面采用的是对传感器返回的4~~20mA的电流进行精密处理成为0~~5V电压再进行A/D转换处理。
当仪表采集而得到的数据值或其运算值,达到或超过用户所预置设定的警限值时,仪表除对应地点亮面板上的警示灯外,还会通过对继电器的可编程控制来接通或切断外围动力供电回路,以实现仪表对整个工程运行系统的智能化控制的目的。
输入信号:位移1路SSI/RS422绝对型光电编码器输入
1路4~20mA电流型光电编码器输入
荷重2路4~~20mA荷载传感器输入
输出信号:3路模拟量4~~20mA输出,开度、双荷重
报警输出:8路继电器型无源触点,输出可编程
安装方式:面板式安装,面板尺寸(宽×高)175×100mm
,开孔尺寸(宽×高×深)170×97mm×216mm
界面11
再选定“开度上限值”和“开度下限值”分别显示“界面12”和“界面13”,在界面中可对开度上下限值进行设定。
界面12界面13
再按“切换”键显示二级参数设定“界面14”。
界面14
在“界面14”中,选定“载荷报警值”,显示“界面15”可对载荷报警原值进行更改,设定载荷报警值后仪表将根据载荷报警值的90%和110%输出报警信号;选定“载荷额定值”,显示“界面16”可对载荷额定原值进行更改,载荷额定值是设定荷重传感器输出20mA电流时所对应的载荷吨位值即设定仪表荷重量程;选定“偏载报警值”,显示“界面17”可对偏载报警原值进行更改;
六.操作说明………………………………………………6
七.连线说明………………………………………………12
八.注意事项………………………………………………13
九.产品的质量保证和售后服务…………………………13
一.概述
JHHK-1HA系列闸位和荷重测控仪是专为各种闸门起闭机设计的闸门开度和荷重测控装置。既可显示平板闸门、弧形闸门等的提升高度和起吊重量,又可控制闸门升降至给定高度,并有闸位,荷重90%、110%超限报警,继电器触点输出控制功能,可立即切断动力供电回路。
(2).实际载荷2:载荷2的实际值,当实际值达到载荷2报警值90%时,荷载2的90%报警灯亮,达到110%时110%报警灯亮;
(3).载荷总计:载荷1和载荷2的总和;
(4).实际偏载:载荷1和载荷2的偏差,当偏载值达到设定的偏载报警值时,偏载灯亮;
四.工作原理:
本仪器是采用高性能、高稳定性的PIC单片机来作为处理核心的,使用高精度(16位)的A/D和(12位)D/A转换模块来进行数字和模拟信号间的相互转换,并在通讯上内嵌了RS-485通讯接口,以此来提高整个数据处理系统的精度和稳定性。
7.大容量无源触点输出,功能可编程,控制、报警功能强大。
8.具有掉电记忆功能,各种预置数据在停机后再加电开机无需作任何调整即可投入使用。
9.内嵌RS—485通讯接口,便于组网通讯,实现远程监控。
10.具有开度零位校准功能,便于现场调整基准。
11.开度光柱指示灯。
三.产品功能
本产品主要用在平板闸门、弧形闸门等闸门控制中,既能显示提升高度和起吊重量,还可以控制闸门的升降至给定的高度,并有闸位荷重超限报警、显示开度和荷载的功能。
仪表信号线接口管脚定义图
八.注意事项:
1.仪表外壳要有可靠的接地线。
2.禁止仪表连线插头带电插拔。
3.仪表工作位置远离强电磁场。
4.非专业人员禁止自行打开仪表外壳,如有故障请与厂商联系。
5.参数设置密码必须牢记,否则无法进入二级参数设定界面。
九.售后服务和产品质量保证:
1.本产品自发货之日起1年内,如用户遵守运输,存储和使用规则,而质量低于技术指标的,本厂负责免费维护。
JHHK-1HA
闸门开度荷重测控仪
产品说明书
江河科技有限公司
一.概述……………………………………………………2
二.产品特点………………………………………………2
三.产品功能………………………………………………3
四.工作原理………………………………………………3
五.技术参数………………………………………………5
大屏幕液晶显示器
工作原理框图
五.技术参数:
测量范围:位移(开度)0~~99.99m;载荷单路0~~990t
分辨率:位移(开度)1mm;载荷0.01t
综合精度:位移(开度)±1cm;载荷≤0.5%FS
工作电源:DC24V
环境温湿度:温度—20℃~~+55℃ 湿度≤95%
工作方式:连续
通讯接口:内嵌RS—485通讯接口,或Modbus,Profibus,Interbus可选,数据读写周期应大于等于100ms