桥架支架理论重量
桥架规格丝杆(100米测算)横担(100米测算)每100米桥架支架重量每米桥架支架重量50*?123.4024.22147.621.4875*?123.4028.26151.661.52100*?123.4032.29155.691.56150*?123.4040.37163.771.64200*?123.4048.44171.841.72250*?123.4056.51179.911.80300*?123.4064.59187.991.88400*?123.4080.73204.132.04500*?123.4096.88220.282.20600*?123.40113.03236.432.36700*?123.40129.17252.572.53800*?123.40145.32268.722.691000*?123.40177.61301.013.01 桥架支架理论重量(利用丝杆吊装)
电缆桥架理论重量一览表
槽式电缆桥架理论重量速在表(k#m)
序 桥架规格 厚度 有盖板 无盆板 系13 系15 系1.6 备注
1 100*50 0.8 22 16 枣数1.3即
Tl/Kg 以下相同 L0 25 19
L2 3.3
24
15 4.1 29 系数1.5即
元;Kg 以下相同
2 100*100 1.0 3.5 25
L2 4.2
30
1.5 5.3
38 系数L7即
元;Kg 以下相同 2-0 7.0 49
3 150*75 10 4.0 2K
1.2 48
34 本价格表
为参考
价,可随
时浮动• 1.5 6.0 42
2.0 8.0 56
4 200*100 1.2 53
38
1.5 7.8
55
20 10 70 表中红色
字体为标
准板厚 5 250*100 1,2 7.2
51
1.5 9.0 63
2.0 12
85
6 300*100 1,2 8.2 60
1.5 10.3
75
2,0 13.7 96
7 350*100 1.5— 10.8 80
20 100
400*100 1.5 12.5 90
? 0 16.7 117
2,5 20.8 146
9 500*100 1,5 14.8 105
2.0 19.8 140
2,5 24.8 175
桥架规格 厚度 白盖板
系】3 系15 系】6 备注
10 600*100 1.5 173 125
2.0 23.1
165
2.5 28.8 205
11 700*100 2.0 26.3 185
2.5 32.9一 230
3.0 39.5
278
12 803*100 2,0 29,7
桥架吊架工程重量计算表
序号桥架宽度(mm)横梁∠40×4角钢重量双头螺栓M10长度(米)双头螺栓M10重量(2根)预埋件120*60*6(2块)固定架-40*4镀锌扁钢(2个)螺母M10(10个)螺栓M8*30(4个)
11000.48440.91.11060.080.044422000.72660.91.11060.080.044433000.96880.91.11060.080.044444001.2110.91.11060.080.044455001.45320.91.11060.080.044466001.69540.91.11060.080.044477001.93760.91.11060.080.044488002.17980.91.11060.080.044499002.4220.91.11060.080.04441010002.66420.91.11060.080.0444
根据图集04D701-82方案九计算桥架支撑架重量计算表螺母M8(4个)垫圈(4个)单个支撑架重量
0.0161.740.0161.980.0162.220.0162.460.0162.700.0162.950.0163.190.0163.430.0163.670.0163.92
桥架支架重量计算公式
桥架:
电缆桥架分为槽式电缆桥架、托盘式电缆桥架和梯级式电缆桥架、网格桥架等结构,由支架、托臂和安装附件等组成。可以独立架设, 也可以敷设在各种建(构)筑物和管廊支架上,体现结构简单、造型美观、配置灵活和维修方便等特点,全部零件均需进行镀锌处理,安装在建筑物外露天的桥架,如果是在邻近海边或属于腐蚀区,则材质必须具有防腐、耐潮气、附着力好, 耐冲击强度高的物性特点。
胀缩问题:
由于环境温度变化,钢质电缆桥架会出现热胀冷缩的现象。室外桥架受温度影响较大例如环境最高温度为40℃,最低温度为-20℃,则电缆桥架的最大收缩量按下式求得:
Δt=11.2 ×10-6×60deg(度)×1000mm
由此得出结论:
温差为60℃时 ,Δι =0.672mm/m
温差为50℃时, Δι =0.560mm/m
温差为40℃时, Δι =0.448mm/m
工程设计中直线段电缆桥架应考虑伸缩接头,伸缩接头的间距建议按以下取定:
当温差为40℃时为50m;
当温差为50℃时为40m;
接地:
根据规范的有关规定,镀锌电缆桥架进行良好的接地。 (1)镀锌电缆桥架直接板每个固定螺栓接触电阻
应小于0.005Ω,此时电缆桥架可作为接地干线(喷粉电缆桥架不宜作接地干线),每个电缆桥架的电阻值可按下式计算:
r=ρ·L/S
式中:ρ =15×10Ω-6 / cm(20℃);
L=长度按100mm计算;
S=截面积cm2。
(2)梯架于托盘的单位电阻值见表2。
表2 梯架于托盘的单位电阻值
(3)电缆槽的单位电阻值见表3
(4)当电缆桥架安装连接程整体后,每根梯边(或每个电缆槽)的电阻为:
R=L(r+1/3r’)
式中:
R--梯边,即(电缆槽)全长总电阻(mΩ);
r--梯边单位长度电阻(mΩ/m)
桥架重量计算公式
桥架重量计算公式
桥架重量计算公式是用于确定桥架重量的重要公式,它可以帮助工程师确定桥架的重量,以便维护它的安全性和稳定性。
桥架重量计算公式有许多种形式,但最常用的是基于结构的公式。在这种计算公式中,桥架的重量取决于桥架的长度、宽度、高度和材料类型。比如,若架子的长度为7.2米,宽度为2.4米,高度为1.2米,材料类型为木材,则其重量可以通过以下公式来计算:
重量 = 长度 × 宽度 × 高度 × 材料密度
其中,材料密度是指桥架材料的密度,通常以千克/立方米(kg/m3)为单位。因此,在上述示例中,木材的密度可以认为是700 kg/m3,则桥架的重量可以计算为:
重量 = 7.2 × 2.4 × 1.2 × 700 = 10368 kg
在计算桥架重量时,还需要考虑桥架上的其他结构,如桥墩、支座、支架等,它们的重量也需要计算在内。
计算桥架重量时,还需要考虑桥架的类型,也就是说,不同类型的桥架重量也会有所差别。例如,钢桥的重量要比木桥重,因为钢的密度大于木材的密度。同时,桥架的尺寸也会影响重量,因此,同一种材料的桥架,大小不同,重量也会有所不同。
桥架重量计算公式是一种重要的计算公式,可以帮助工程师确定桥架的重量,以保证桥架的安全性和稳定性。
电缆桥架理论重量
电缆桥架:
序号 规 格 单 位 桥架重量 (kg/m)
梯级式 托盘式带盖 槽合式 组合式
1 100×50 m - - 6.00 2.00
2 150×75 m 5.00 6.00 8.00 3.00
3 200×60 m 6.00 7.50 - 3.50
4 200×100 m 7.50 9.00 12.00 -
5 300×60 m 6.50 10.00 - -
6 300×100 m 8.00 11.50 - -
7 300×150 m 10.50 13.00 17.00 -
8 400×600 m 9.00
12.50 - -
9 400×100 m 10.50 14.50 - -
10 400×150 m 13.00 17.00 - -
11 400×200 m - - 25.00 -
12 500×60 m 11.00 15.00 - -
序号 规 格 单 位 桥架重量 (kg/m)
梯级式 托盘式 槽合式 组合式
13 500×100 m 12.50 17.00 - -
14 500×150 m 14.50 20.00 - -
15 500×200 m - - 30.00 -
16 600×60 m 12.50 18.00 -- -
17 600×100 m 14.00 20.00 - -
18 600×150 m 16.00 23.00 - -
19 600×200 m - - 35.00 -
20 800×100 m 16.00 26.00 - -
21 800×150 m 18.00 29.00 - -
电缆桥架规格重量表
槽体护罩槽体护罩槽体护罩槽体护罩槽体护罩槽体护罩100×501.7613.1152.1811.2322.9591.6733.7382.1131.8691.0562.6481.497150×754.6862.1933.7491.7544.922.3036.0922.8513.0461.4254.2171.974200×1007.7644.1536.9883.7378.9294.77610.875.8145.4352.9077.3763.945250×15010.7954.73210.7954.73213.4945.91516.1937.0988.0963.54910.7954.732300×1009.5695.95812.447.74615.7899.83124.87915.4917.6554.76710.5266.554300×15011.3755.95814.7887.74618.7699.83129.57515.49114.7885.95815.3568.044400×10011.3757.76418.212.42222.7515.52727.318.6339.16.21114.2199.705400×15013.187.76421.08812.42226.3615.52731.63218.63317.1347.76417.79310.481400×20014.9867.76423.97812.42229.97215.52735.96618.63317.9839.31623.97812.422500×10016.47511.96129.65521.5336.24526.31542.83531.09916.47511.96123.06516.746500×15018.73311.96133.71921.5341.21326.31548.70631.09922.4814.35328.117.942500×20020.98911.96137.7821.5346.17626.31554.57131.09929.38516.74633.58219.138600×10018.73314.21937.46628.43744.95934.12552.45239.81222.4817.06226.22619.906600×15020.98914.21941.97828.43750.37434.12558.76939.81229.38519.90631.48421.328600×20023.24614.21946.49228.43755.7934.12565.08939.81237.19422.7537.19422.75800×10023.24618.73255.7944.95865.08952.45174.38759.94427.89522.47932.54426.225800×15025.50318.73261.20744.95871.40852.45181.6159.94435.70426.22538.25528.099800×20027.7618.73266.62444.95877.72852.45188.83259.94444.41629.97244.41629.972备注: 1. 100×50~150×75桥架厚度采用δ=1.5mm;200×100~400×200桥架厚度采用δ=2.0mm; 500×100~800×200桥架厚度采用δ=2.5mm; 2. 托盘式桥架重量与槽式桥架重量相同; 3. 梯级式桥架重量是槽式桥架重量乘0.8计算。规格电缆桥架规格重量表直通水平弯通水平三通水平四通垂直上、下弯通上、下垂直等径三通
常用电缆桥架的单位长度与重量换算表
桥架的单位长度与重量换算表及公式
换算表, 电缆桥架, 公式, 重量, 单位
按展开周长计算,重量=2*(边长+高)*板厚*7.9.板厚300以下按2.0mm计算
(近似值),300-500按2.5计算,600以上按3.0计算.
上述公式适用于带盖板的槽式桥架,不适用于梯级式桥架及不带盖板的
托盘式桥架.
常用电缆桥架的单位长度与重量换算表
(1)立柱及托臂(包括底座重量)
立 柱托 臂
规 格单位重量 (kg/件)规 格单 位重量
(kg/件)一般轻型
工字型
h=100m15.7010.39臂长
150件1.21
丁字型
h=100m14.509.12臂长
200件1.42
槽钢型 6#m10.138.54臂长
300件1.94
槽钢型 8#m11.54-臂长
400件2.43
槽钢型
10#m13.50-臂长
500件2.92
角钢型 60m9.026.38臂长
600件3.4l
角钢型 75m12.43-臂长
700件3.90
----臂长
800件4.40
注 :a.根据设计图纸和电缆桥架的单位荷重(kg/m)选用立柱的规格和数量(立柱间的距离从O.5m至2.Om)。
b.(2)“电缆桥架的单位长度与重量换算表”仅供在设计资料不全时
作为编制电缆桥架安装费的工程量参考数据,不作为主材成品订货和结
算的依据。电缆桥架的成品数量应按设计量或实际数量结算。重量误差
小于5%的可以不调整。
c.电缆桥架重量包括弯通、三通和联接部件等综合平均每m长的桥架
重量。
d.利用型钢作支撑架,而不用托臂的电缆桥架,其支撑架的重量按设
计图纸计算,但整套桥架仍按总重量执行电缆
桥架综合定额。
(2)电缆桥架:
序
号规 格单
位桥架重量 (kg/m)
梯级式托盘式槽合式组合式
1100×50m--6.002.00
2150×75m5.006.008.003.00
3200×60m6.007.50-3.50
4200×100m7.509.0012.00-
5300×60m6.5010.00--
6300×100m8.0011.50--
电缆桥架理论重量一览表 2
电缆桥架理论重量一览表(总4页)
-CAL-FENGHAI.-(YICAI)-Company One1
-CAL-本页仅作为文档封面,使用请直接删除 槽式电缆桥架理论重量速查表(kg/m)
序 桥架规格 厚度 有盖板 无盖板 系 系 系 备 注
1
100*50 16 系数即元/Kg
以下相同 19
24
29 系数即
元/Kg
以下相同
2
100*100 25
30
38 系数即
元/Kg
以下相同 49
3 150*75 28
34 本价格表为参考价,可随时浮动。 42
56
4
200*100 38
55
10 70 表中红色字体为标准板厚
5
250*100 51
63
12 85
6
300*100 60
75
96
7 350*100 80
100
8
400*100 90
117
146
9
500*100 105
140
175 序 桥架规格 厚度 有盖板 无盖板 系 系 系 备 注
10
600*100 125
165
205
11
700*100 185
230
278
12
800*100 210
260
312
13
900*100 235
290
347
14
1000*100 255
317
380
15
200*150 65
C型钢(41x41、41x72等)规格及理论重量表--电缆桥架、太阳能支架用
b1
b2
tb1b2t
0.800.890.651.202.291.72
1.001.100.801.502.832.12
1.201.300.941.803.352.52
1.501.591.152.003.702.77
1.801.861.352.504.533.40
2.002.041.482.754.933.70
1.201.641.213.005.324.00
1.502.021.491.202.531.91
1.802.381.761.503.132.36
2.002.621.931.803.712.80
2.503.182.342.004.103.09
2.753.442.542.505.033.78
3.003.702.722.755.484.12
1.201.791.333.005.924.45
1.502.211.641.202.772.09
1.802.611.941.503.432.59
2.002.872.131.804.073.08
2.503.492.592.004.503.40
2.753.792.812.505.534.17
3.004.083.022.756.034.55
1.202.051.533.006.524.92
1.502.531.89
1.802.992.24
2.003.302.46
2.504.033.00
2.754.383.26
3.004.723.5241*625
41*72
41*8276
41*41
41*521
2
3
441.341.3C型钢理论重量表(电缆桥架、太阳能支架用)
尺寸(mm)尺寸(mm)序号理论重量kg/m序号截面积cm2
41*21 左图中为C型钢: b1:为短边边长 b2:为长边边长 t:为壁厚
41.335理论重量kg/m截面积cm2规格
41*35规格
41.35241.362
41.372
41.38241.320.6
桥架支架重量计算
序号线槽型号(大边长)吊杆直径(mm)吊杆长度(m)吊杆每米重量吊杆根数吊杆重量合计紧固螺栓单个重量螺栓个数螺栓总重量螺母单个重量螺母个数螺母总重量平(弹)垫圈平均单个重量垫圈个数垫圈总重量吊架角钢规格长度每米重量角钢总重量每个支架合计总重量支架间距(m)
110081.10.39520.8690.11110.1110.004250.02110.000865100.00930*30.211.3730.28832.27181.52200101.10.61721.3570.18910.1890.007950.03970.00174100.01730*30.211.3730.28832.78751.53300101.10.61721.3570.18910.1890.007950.03970.00174100.01730*30.311.3730.42562.78751.54400101.10.61721.3570.18920.3780.007960.04760.00174120.02140*40.412.4220.9933.84791.55500121.10.88821.9540.02720.0540.011960.07160.00313120.03840*40.512.4221.23524.48471.56600121.10.88821.9540.02720.0540.011960.07160.00313120.03850*50.613.772.29975.83271.5
3、因600以上桥架较为少用故此没有列入。电缆桥架一般支架重量计算
2、规范及标准图集规定桥架支、托、吊架间距为1.5-2.0m,应按1.75米计算,但另考虑端头及转角、三、四通、转弯等因素影响,但又考虑一般桥架直线。故此按1.5m间距考虑较为适宜。注: 1、螺栓长度按30mm计入.单位:kg平均每米桥架支架含量(重量)
1.511.861.862.572.993.89