JY系列连杆浮球液位开关选型说明
液位开关选型指南说明书

LIQUID LEVEL SWITCHES – Selection GuideThis document provides an overview of SST Sensing’s liquid level switches; you will find information regarding important features such as housing and thread types, dimensions, working voltages and best suited applications of particular switch types.NOTE: This document is not intended to replace the product datasheets which are referenced within. For ordering information and detailed specifications please refer to the datasheets or contact ********************.Contents1 THINGS TO CONSIDER ............................................................................................................. 1-12 SWITCH TYPES ........................................................................................................................ 2-1 2.1 Optomax Digital Range .................................................................................................... 2-1 2.2 Optomax Industrial Range ............................................................................................... 2-1 2.3 Optomax Industrial Glass Range ...................................................................................... 2-1 2.4 LLHP (High Performance) Range ...................................................................................... 2-2 2.5 POS Range....................................................................................................................... 2-22.6 Optomax Basic Range ...................................................................................................... 2-23 SPECIFICATIONS ...................................................................................................................... 3-1 3.1 Optomax Digital Range .................................................................................................... 3-1 3.2 Optomax Industrial Range ............................................................................................... 3-3 3.3 Optomax Industrial Glass Range ...................................................................................... 3-5 3.4 LLHP (High Performance) Range ...................................................................................... 3-7 3.5 POS Range....................................................................................................................... 3-9 3.6 Optomax Basic Range .................................................................................................... 3-11 APPENDIX A – SWITCH QUICK COMPARISON TABLE ........................................................................ A-1Figure 1-2 Low / High Level IndicationFigure 1-1 Leak Detection1 THINGS TO CONSIDEROptical liquid level switches do not measure the liquid level, instead they detect the presence or absence of liquid.There are a number of things to consider when choosing a liquid level switch:Mounting position; where the switch is to be mounted can narrow the selection field, for example, is space a restrictive factor?Application; where the switch is to be used can narrow the selection field:∙ Food or beverage application? ∙ Medical or chemical handling?Environmental factors; the environment in which your switch will be working has a direct bearing on the material type you should select. Fluid type and temperature are key factors; for example, is the liquid corrosive; high or low temperature?SST offers three housing material options depending on switch type; Polysulfone, Trogamid® (EU food-contact grade) or stainless steel.Again, depending on switch type, SST offers three tip material options; Polysulfone, Trogamid® (EU food-contact grade) or glass.NOTE: If you need a switch other than those listed in this document, contact SST Sensing ; we will be happy to discuss your requirements.Refer to AN-0041, Liquid Level Switches – Installation, Operation and Compatibility Guide for a list of compatible fluids. These lists are not exhaustive, SST recommends testing a sample sensor in the fluid you intend operating in, refer to AN-0041 for details of the test procedure.NOTE: Typical applications are listed throughout this document; they are given as examples only; they are NOT the only applications in which the switches operate. Contact SST Sensing if you require assistance identifying the most suitable switch to suit your needs.2SWITCH TYPESThere are six switch ranges within the liquid level family; Optomax Digital, Optomax Industrial, Optomax Industrial Glass, LLHP, POS and Optomax Basic. The following gives a brief overview of the switch, refer to 3 SPECIFICATIONS starting on page 3-1 for further details:2.1Optomax Digital RangeOperating voltage: 4.5V to 15.4V DCOperating temperature range: -25o C to + 80o C or -40o C to +125o CTypical applications: Best suited for low power signalling of liquidpresence/absence.2.2Optomax Industrial RangeOperating voltage: 4.5V to 15.4V DC or 8V to 30V DCOperating temperature range: -25o C to + 80o C or -40o C to +125o CTypical applications: Designed where high power signalling of liquidpresence/absence is required, or, operation at higher (industrial)voltages. Industrial range switches are capable of driving high powerloads, and are able to (depending on output type) sink/source up to 1A.2.3Optomax Industrial Glass RangeOperating voltage: 4.5V to 15.4V DC or 8V to 30V DCOperating temperature range: -40o C to +125o CTypical applications: All the technical capabilities of the OptomaxIndustrial Range with the added benefits of a stainless steel housing andglass sensing tip, allowing the sensor to be used in harsh chemicalenvironments.2.4LLHP (High Performance) RangeOperating voltage: 4.5V to 15.4V DC or 10V to 45V DCOperating temperature range: -25o C to + 80o C or -40o C to +125o CTypical applications: Comes in a rugged metal housing, designed for aggressive environments. Capable of withstanding high and low temperatures and with options for high switching currents. They have multiple output configurations and several thread types available, or, if required can be supplied with a custom thread type.2.5POS RangeOperating voltage: 12V to 28V DCOperating temperature range: -25o C to 100o C or -40o C to + 140o CTypical applications: With its stainless steel housing and Simax crystal glass sensing tip, the POS range is ideally suited for use in harsh chemical environments.2.6Optomax Basic RangeOperating voltage: 3.3V to 24V DCOperating temperature range: -25o C to + 80o CTypical applications: Designed primarily with price sensitive high volume OEM applications in mind, for example white goods, vending machines, and automotive applications. Requires a clean, protected, and stable power supply and an available microcontroller, or other circuit, to determine whether the sensor is in air or liquid based on its analogue output voltage.NOTE: Power supply and microcontroller not supplied with the switch.3SPECIFICATIONSThe following section provides high-level switch specifications; for full details, refer to the product datasheet (see REFERENCE DOCUMENTS for details).3.1Optomax Digital RangeFor full specification details, refer to the datasheet.3.1.1Mounting and Housing Types3.1.2Product Dimensions5x0 Series 2x0 Series6x0 Series 7x0 SeriesFigure 3-1 Product Dimensions – Optomax Digital Rangea Hex nut and O-ring sold separately.b When correctly sealed.3.1.3Circuit DiagramsFigure 3-2 Circuit Diagrams - Optomax Digital Range3.2Optomax Industrial RangeFor full specification details, refer to the datasheet.3.2.1Mounting and Housing Types3.2.2Product Dimensions2x0 Series6x0 Series 7x0 SeriesFigure 3-3 Product Dimensions – Optomax Industrial Rangec Hex nut and O-ring sold separately.d When correctly sealed.3.2.3Circuit DiagramsFigure 3-4 Circuit Diagrams - Optomax Industrial Range3.3 Optomax Industrial Glass RangeFor full specification details, refer to the datasheet. 3.3.1Mounting and Housing Types3.3.2 Product DimensionsFigure 3-5 Product Dimensions – Optomax Industrial Glass Rangee Hex nut and O-ring sold separately.fDo NOT over-tighten as this can permanently damage the sensor. gWhen correctly sealed.G7x0 Series G8x0 SeriesG6x0 SeriesG2x0 Series3.3.3Circuit DiagramsFigure 3-6 Circuit Diagrams – Optomax Industrial Glass Range3.4LLHP (High Performance) RangeFor full specification details, refer to the datasheet.3.4.1Mounting and Housing Types3.4.2Product DimensionsFigure 3-7 Product Dimensions – LLHP Range h When correctly sealed.3.4.3Circuit Diagrams4.5V – 15.4V DCFigure 3-8 Circuit Diagrams - LLHP Range; 4.5V – 15.4V DC 10V – 45V DCFigure 3-9 Circuit Diagrams - LLHP Range; 10V – 45V DC3.5POS RangeFor full specification details, refer to the datasheet.3.5.1Mounting and Housing Types3.5.2Product DimensionsFigure 3-10 Product Dimensions – POS Range i When correctly sealed.3.5.3Circuit DiagramsFigure 3-11 Circuit Diagrams - POS Range3.6Optomax Basic RangeFor full specification details, refer to the datasheet.3.6.1Mounting and Housing Types3.6.2Product Dimensions500 Series 200 Series600 Series 700 SeriesFigure 3-12 Product Dimensions – Optomax Basic Range j Hex nut and O-ring sold separately.k When correctly sealed.3.6.3Circuit DiagramsThree and four wire options are available. Refer to the datasheet for details on R LED and R PULL-UP resistor calculations.3-wire version 4-wire versionFigure 3-13 Circuit Diagrams - Basic RangeNOTE: The 4-wire version provides galvanic isolation between input (IR-LED) and output (phototransistor).APPENDIX A – SWITCH QUICK COMPARISON TABLEThe following table provides a quick comparison of the switch ’s key attributes:Part Number ConventionL L X 5X 0D 3XL L X X X 0D 3X S HL L X X X 0D 3X X X -X X XL L G X 10D 3X X X -X X XL L H P X X X X X XP O S X 87X X X -X X XL L X 500A XL L X X 00A X S H TypeDigital✓ ✓Industrial ✓ Industrial Glass✓ HP ✓ POS ✓ Basic✓ ✓ Housing MaterialPolysulfone✓ ✓ ✓ ✓ ✓ Trogamid®✓ ✓ ✓ ✓ ✓ Stainless Steel✓ ✓ ✓ Thread TypeM10✓ ✓ M12 ✓ ✓ ✓ ✓ ½” SAE ✓ ✓ ✓ ✓ ¼” NPT ✓ ✓ ✓ ✓ ½” NPT ✓ ✓ ✓ 3/8” BSP ✓ ½” BSP✓ (G½”) ½” BSPP ✓ ¾”-16 UNJF✓ Operating Temp.-25°C to +80°C✓ ✓ ✓ ✓ ✓ ✓ -25°C to +100°C✓ -40°C to +125°C✓ ✓ ✓ ✓ ✓ -40°C to +140°C✓ Supply Voltage4.5 to 15.4V✓ ✓ ✓ ✓ ✓ 12 to 28V ✓ 8 to 30V ✓ ✓ 10 to 45V ✓ 3.3 to 24V l✓ ✓ Output TypePhototransistor m✓ ✓ Push Pull✓ ✓ ✓ ✓ ✓ P-Type ✓ ✓ ✓ ✓ N-Type✓ ✓ ✓ ✓ N-Type (fly back) ✓ ✓ N-Type (10Ω pull-up)✓ ✓ Output LogicLow in Air ✓ ✓ ✓ ✓ ✓ ✓ High in Air ✓✓ ✓ ✓ ✓ ✓ PWM ✓ ✓Key:✓: Standard | ✓: Customer provideslAny with suitable LED current limiting resistor.mPhototransistor open collector. Refer to circuit diagrams on page 3-12.REFERENCE DOCUMENTSOther documents in the liquid level product range are listed below; this list is not exhaustive, always refer to the SST website for the latest information:CAUTIONDo not exceed maximum ratings and ensure sensor(s) are operated in accordance with their requirements.Carefully follow all wiring instructions. Incorrect wiring can cause permanent damage to the device. SST Sensing Ltd recommend using alcohol based cleaning agents. DO NOT use chlorinated solvents such as trichloroethane as these are likely to attack the sensor material.Failure to comply with these instructions may result in product damage.INFORMATIONAs customer applications are outside of SST Sensing Ltd.’s control, the information provided is given without legal responsibility. Customers should test under their own conditions to ensure that theequipment is suitable for their intended application. Before use, check that the fluid in which you wish to use these devices is compatible with Polysulfone, Trogamid® or Stainless Steel.For technical assistance or advice, please email: ************************SST SENSING LIMITED, 5 HAGMILL CRESCENT, SHAWHEAD INDUSTRIAL ESTATE, COATBRIDGE, UK, ML5 4NS | e: ******************** | t: +44 (0)1236 459 020 | f: +44 (0)1236 459 026。
浮球液位开关的相关选型介绍 浮球液位开关如何操作

浮球液位开关的相关选型介绍浮球液位开关如何操作液位开关和变送传感器可以选配,用于液位上下限报警和掌控;将液位信号转换成二线制(4—20)mA 标准信号实现远距离测量、记录指示与掌控。
其中浮球液液位开关和变送传感器可以选配,用于液位上下限报警和掌控;将液位信号转换成二线制(4—20)mA 标准信号实现远距离测量、记录指示与掌控。
其中浮球液位开关是一种能够很好的对液位高处与低处起到检测并且输出开关触点信号的配件。
对于其关于选型的注意事项如下:1、不锈钢浮球开关产品参考比重以水(SG=1)所以使用时在选用浮球时须考虑液位的比重;确定大于浮球规格所标示,否则,浮球开关无法浮起。
2、液体比重不同时,浮球的动作位置将会有所变动,一般SG 比水小时,浮球浸在液体中部分将相对增多。
3、请依照被测物的使用温度、压力、比重、耐酸碱等特性选择适合的不锈钢浮球。
4、压力:塑胶类浮球耐压最大5kg/cm2,SUS浮球耐压最大20kg/cm2、不锈钢浮球5、粘度高但不会干枯的液体,一般应选用外径较大的不锈钢浮球。
同时,选型相对应的参数确定,需要注意以下几点:1、材质要求:(材质可选:PP/PVDF/不锈钢304、316、316L、四氟等,材质不同所能够使用的环境也不相同)2、导杆长度:mm(从实际安装面到需要检测的液位距离)3、线材要求:(常规出线350mm,线材可选高温编织线、高温耐腐蚀特氟龙线、低温线、护套线等等)4、螺牙大小:(依据安装环境而定,如:水箱不是全密封而且为设备内置则可选择螺母固定;室外水箱或者水池则建议选择法兰跟接线盒;密封性水箱接受大于浮球外径的外螺纹)5、浮球材质及大小:(材质依据实际使用环境情况)6、出线几条:(依据选取动作点个数而定,一般两条为掌控一个点,但也可做三条线,如两个动作点显现三条,其中一条为公共线)—专业分析仪器服务平台,试验室仪器设备交易网,仪器行业专业网络宣扬媒体。
相关热词:等离子清洗机,反应釜,旋转蒸发仪,高精度温湿度计,露点仪,高效液相色谱仪价格,霉菌试验箱,跌落试验台,离子色谱仪价格,噪声计,高压灭菌器,集菌仪,接地电阻测试仪型号,柱温箱,旋涡混合仪,电热套,场强仪万能材料试验机价格,洗瓶机,匀浆机,耐候试验箱,熔融指数仪,透射电子显微镜。
浮球液位开关(周书阳)讲解

1500mm 4
PART ONE
LV30- LOR250 EM IPSUM 500 750 1000 1250 1500 S A 1 2 3 4 F G
LV30系列浮球式位开关(计) 测量范围 250mm 测量范围 500mm 测量范围 750mm 测量范围 1000mm 测量范围 1250mm 测量范围 1500mm 开关量输出型 模拟量输出型 4…20mA 浮球数:1个 浮球数:2个(仅限开关输出型产品) 浮球数:3个(仅限开关输出型产品) 浮球数:4个(仅限开关输出型产品) 法兰连接DN50法兰 螺纹连接G2
应用示例和注意事项
THANK YOU
型号特点
(以电缆浮球液位开关为例)
主要特点
适用范围广、安装形式多样 多点控制 无源器件,性能稳定可靠,抗干扰能力强 结构简单,安装方便,维护费用低 多种材质可以选择,适合多种场合使用
浮球液位开关LV30系列
有效长度 L 最多浮球数量
250mm 2
500mm 3
750mm 4
1000mm 4
1250mm 4
介质密度: 0.5~2.0g/cm3
介质粘度: ≤0.8Pa s 3Pa s
连接:螺纹或法兰
接线形式:普通接线盒或防爆接线盒或甩线
外壳防护:IP65
选型考虑:
浮球液位开关分为固定磁浮球液位开关和可调磁浮球液位开关,选择磁浮球液
位开关的一个型号时要考虑固定或可调磁滞现象,液体密度,安装位置和过程连
接。
浮球液位开关
周书阳
简介 结构和原理 型号特点 参数 应用示例和注意事项
简介
浮球液位开关的技术优势:浮球开关不含导致故障发生 的 波纹管、 弹簧、密封等部件。而是采用直浮子驱动开关内部磁铁,浮球开关的 简捷的杠杆使开关瞬间动作。浮子悬臂角限位设计,防止浮子垂直。 浮球液位开关是一种结构简单、使用方便、安全可靠的液位控制器。 它比一般机械开关速度快、工作寿命长;与电子开关相比,它又有抗负 载冲击能力强的特点,一只产品可以实现多点控制。其在造船、造纸、 印刷、发电机设备、石油化工、食品工业、水处理、电工、染料工业、 油压机械等方面都得到了广泛的应用。浮球开关是一种结构简单、使 用方便、安全可靠的液位控制器件,它具有比一般机械开关体积小、 速度快、作用寿命长,与电子开关相比,它有抗负载冲击能力强的特 点。
各液位开关的优缺点及技术指标

浮球液位开关优点:浮球开关不含导致故障发生和波纹管、弹簧、密封等部件。
而是采用直浮子驱动开关内部磁铁,浮球开关的简捷的杠杆使开关瞬间动作。
浮子悬臂角限位设计,防止浮子垂直。
浮球液位开关是一种结构简单、使用方便、安全可靠的液位控制器。
它比一般机械开关速度快、工作寿命长;与电子开关相比,它又有抗负载冲击能力强的特点,一只产品可以实现多点控制。
易于维护。
广泛使用于造船、造纸、印刷、发电机设备、石油化工、食品工业、水处理、电工、染料工业、油压机械等方面。
缺点:浮球开关是简单的被动器件,并且不具有自检查功能,因此建议对其进行定期检查与维护。
浮球或浮筒物位计是活动部件,因此用在更浓或黏稠液体中时会被弄脏。
测量精度较差,黏度<0.8mpa*s时不能工作。
对容器内压力、密度、介电常数有要求、安装需停产、清罐、开孔、动火。
技术指标:最大电缆长度:30m工作温度:标准型:0~80℃中温型:0~120℃环境温度:-40~70℃工作压力:常压介质密度:≥0.6g/cm 触点容量:220VAC 10A 电气接口:M20*1.5防护等级:IP65过程连接:HG20592~20635-97 DN100以上,其他法兰标准(如GB、JB/T、HGJ、ANSI、DIN等)接液材质:不锈钢。
音叉液位开关优点:振动音叉开关能真正地免受流量、气泡、湍流、泡沫、振动、固体含量、沾敷、液体特性以及产品变化的影响。
并且不需要校准,只需要经历最短的安装过程便能完成安装。
无活动零件或缝隙真正实现免维护。
强大的自检查与诊断功能保证了高低物位测量的高可靠性,某些型号的物位计甚至可以在出现故障之前,绘出性能曲线和发送故障趋势信号。
缺点:音叉开关不适合用于非常粘的介质。
导致叉子被连接在一起的叉间物料堆积,将干扰物位检测。
技术指标:电源:DC12V~24V,AC220 功率消耗:1W3、振动频率:200Hz4、输出:NPN型、晶体管输出、最大30V、100mA(过压和过流有可能烧坏)材质:316不锈钢防护:IP68 最大压力:1MPa 密度:液体≥0.8克/立方厘米粉料≥0.2克/立方厘米液体粘度:最高1000㎡/s 检测时间:输出动作(停振)0.5秒输出关闭(起振)3秒工作温度:‐10℃~+85℃电容式液位开关优点:防挂料,耐腐蚀。
浮球液位开关-百度百科

浮球液位开关-百度百科
一、概述
嘉可仪表JK系列浮球液位开关把一个或多个磁簧开关固定在密闭的非导磁的导管内,当内部中空且固定有永久环形磁钢的浮球在液体浮力的作用下、沿导管接近磁簧开关时,磁簧开关在磁力的作用下触点闭合(ON);反之,当浮球远离磁簧开关时,触点断开(OFF),从而输出一个或多个开(ON)或关(OFF)的信号,供报警提示或远程控制。
嘉可仪表JK系列浮球液位开关产品种类齐全,主要有连杆浮球液位开关、电缆式浮球液位开关、不锈钢浮球液位开关、小型浮球液位开关、侧装式浮球液位开关、顶装式浮球液位开关、防爆浮球液位开关、高温浮球液位开关等。
二、产品特点
1、磁簧开关的接点寿命可高达105次;
2、其原理简单,性能稳定可靠,应用范围广;
3、多种材质:SUS、PP、PVC、PVDF、PTFE 等;
4、多种过程连接方式,满足各种环境的需求。
三、技术参数
工作压力:小于2.5MPa;
工作温度:-35~180℃;
触点容量:250V,0.5A;
开关寿命:105次;
介质密度:0.5~2.0g/cm3;
防护等级:IP65;
介质粘度:≤0.8pa.s;
防爆标志:ExiallCT6,ExdllCT6;电气接口:M20x1.5内螺纹;
过程连接:法兰,螺纹,其它定制。
防爆JY3.0加药装置技术协议

加药装置技术协议PAM自动投加装置技术参数型号:JY3.0(防爆型)1.1 性能和结构1.投药装置系统的仪器仪表完善齐全、指示准确。
管路线路整齐,管路无渗漏。
设备操作过程中清洁无粉尘。
该设备结构组成有:干投机(含60L料斗)、干粉浸润装置、槽体、搅拌机、投药及放空管道、配药进水管道、电控柜等。
干投机的驱动部分为蜗轮蜗杆减速电机,高精度的输送螺杆布置在V型料斗的底部,可将料斗内的干粉完全输送出去;通过调节变频器来改变干投机的转速从而实现精确控制干粉投加量。
在输送器的出口处有电加热装置防止湿气侵入粉末。
料斗容积为60L。
上部设有带拉手的不锈钢盖。
靠料斗底部的侧面装设干粉料位计,用以在干粉低位时通过控制柜面板上的“干粉缺”指示灯和蜂鸣器报警。
干投机将干粉送入干粉浸润装置。
干粉浸润装置采用旋流和喷射水流配合,可以彻底混合和浸湿干粉,并通过水射器进入配药罐。
2.溶药储存装置由配药罐、储药罐、防爆电动阀门和搅拌机等组成。
1)配药罐是将干粉和水通过搅拌机混合,以达到稳定,匀质的溶液。
2)储药罐是将配药罐内配好的药液进行储存,供投加泵一定时间的使用。
3)防爆电动阀门安装在配药罐和储药罐之间,由电控柜控制启停。
4)搅拌机安装在配药罐上,对药剂进行充分的搅拌和混合。
3.给水系统由UPVC管路、手动球阀、过滤器、压力表、防爆电磁阀、截止阀等组成。
1)过滤器用来拦截水中的杂质,用来保护电磁阀。
2)压力表安装在过滤器后面,显示压力,如压力过低,则显示过滤器已堵塞,需要清除过滤器中的杂质。
3)防爆电磁阀接收电信号进水,实现自动进水。
4)截止阀用来调节进水流量,调节方便、稳定。
4.控制系统由电气控制柜和液位开关组成。
1)电气控制柜采用西门子PLC,西门子、施耐德电气元件。
2)液位开关采用德国IA磁翻板液位计,测量准确,信号稳定。
5.投加装置投加泵从储存槽底部抽吸0.2~0.5%PAM溶液,然后通过投加泵投加至加药点。
2.2 材质和表面处理输送器、料斗、干粉浸润装置、搅拌机、溶解槽、储存槽等均采用不锈钢SUS304,金属件外表喷金属漆处理。
BL-YW700-浮球液位开关说明书

Tianjin Bily Science and Technology Development Co., Ltd.BL—YW700浮球式液位计典型应用:适用于液体、气体等介质的测量,适用于多种场合。
一、概述YW700系列浮球式液位计,是将液位信号转变为4~20mA的连续电流信号或者电阻信号,通过电缆连接到二次显示仪表或控制室内,以便集中指示和观察。
产品由本体、浮子、法兰盘或螺纹以及液位变送器等组成。
可广泛应用于石油、化工、橡胶、医药、船舶、军事、电力、食品、水处理等行业的各种塔、罐、槽、球形容器和锅炉等设备作介质液面的位置指示和自动控制。
二、产品特点测量范围可根据用户的实际要求制作(2M以上需要定制);指示机构与被测介质完全隔离,密封性好,使用安全;结构简单、安装方便,维护费用低;耐高温,最高耐温达280℃,并可适用多种腐蚀性介质(需定制);多种材质可以选择,适合多种场合使用;性能稳定可靠,抗干扰能力强;三、应用领域适用于液体、气体等介质的测量,适用于多种场合。
四、技术参数量程范围(mm) 300~2000(2000以上需特殊定做)介质密度(g/cm3) 0.5~2工作温度(℃) -40~100℃;-20~200℃;高温订制;压力等级(Mpa) ≤10工作电源 24VDC或12VDC输出信号 4~20mA连接 螺纹或法兰接线形式 普通接线盒或防爆接线盒或甩线五、仪表选型型号说明BL-YW700 -□ /□ /□ /□ /□ /□连接方式 A 螺纹连接(需客户选定)B 法兰连接(需客户选定)输出信号 M 4~20mA输出 V 0-5V输出Tianjin Bily Science and Technology Development Co., Ltd.H 4~20mA+现场显示测量范围 G-□ 量程(单位:M)显示类型 Z LCD液晶显示 E 无显示接线形式 N 不防爆型E 防爆型(防爆等级 Exd II BT4 ) S 直接甩线精度标准 L 0.5%标准精度六、外形尺寸七、安装及注意事项1、被测介质不应含有铁磁性杂质。
浮球液位计选型原理

择。
绝缘阻抗:mi n1010 次方。
型号详解
MH7151
MH7152
接液材质:SUS304/316L 安装方式:垂直安装 安装尺寸:∅10孔
MH7153
接液材质:SUS306/316 安装方式:垂直安装 安装尺寸:∅10孔
MH7155
接液材质:SUS304/316L 安装方式:垂直安装 安装尺寸:∅17孔
上升或下降到与水平面呈一定角度时,浮球体内的 2、结构简单合理,性能稳定可靠
驱动机构驱动大容量微动开关,从而输出开(ON) 3、安装使用非常方便,现场调整简单
或关(OFF)的信号,供报警提示或远程控制使用。 4、广泛应用于给排水及
5、含腐蚀、悬浮物的液位自动控制
MH7162A
MH7162S
MH7162F
磁簧开关在磁力的作用下改变电路的电阻值,电路 防护等级:IP65;
内的分析处理元件检测这一电阻值的变化,并转换 工作温度:-20~180℃(或定制);
成 4 一 20m A 的标准信号输出,实现液位的连续控 介质粘度:≤0.8Pa .S;
制。磁簧开关与精密电阻均匀分布的间隙越小,精 防爆标志:ExiaIICT6,ExdIICT6;
而驱动接线盒内 的微动开关 动作,并输 出开(ON)或
关(OFF)的信号,供报警提示或远程控制使用。
产品类型
基本型
防腐型
高温型
产品选型表
MH7163 侧装浮球开关 代号 安装方式 C 侧装 D 顶装 代号 产品类型 1 基本型(150℃) 2 防腐型(150℃) 3 高温型(400℃) 代号 连接方式 L 螺纹(M20x1.5) F 法兰(DN50) Q 其他定制 代号 介质密度(用户提供)单位:g/cm 代号 工作压力(用户提供)单位:Mpa