葡萄酒中铁含量的测定操作指南
葡萄酒中总铁和Fe2+的改良菲洛嗪法快速测定

葡萄酒中总铁和Fe2+的改良菲洛嗪法快速测定郭安鹊;张星星;张予林;董鑫;陈力维【期刊名称】《农业机械学报》【年(卷),期】2017(48)10【摘要】通过优化菲洛嗪法测定葡萄酒中总铁的检测条件,以及探讨Fe3+共存时菲洛嗪用量对Fe2+测定的影响,建立一种简易可靠、能够直接测定葡萄酒中总铁和Fe2+的方法.结果显示:改良菲洛嗪法测定葡萄酒中的总铁,在0.25 ~2.00 mg/L质量浓度范围内线性关系良好,检测限为0.011 5 mg/L,加标回收率为94.31%~104.34%,变异系数范围为0.95%~2.43%;然而,共存的Fe3+会影响对葡萄酒中Fe2+的测定,适合的显色剂用量是菲洛嗪与总铁摩尔比为7,在此条件下,Fe2+质量浓度的拟合准确度为101.98%~113.50%.利用该法测定葡萄酒样品的结果表明,葡萄酒中以Fe2+为主,其在红葡萄酒中的百分比相对较高.总之,改进的方法简单易行、准确可靠,能够满足葡萄酒中铁价态的快速定量测定,适于在葡萄酒生产中推广应用.%More and more recent literatures have shown that iron and copper,especially iron plays critical roles in the initiation and propagation of wine oxidation,which seems to depend not only on the total concentration of iron,but also more on the speciation of iron in wine.A rapid method for directly accurate determination of total iron and ferrous ion (Fe2+) in wine was developed by optimizing the ferrozine-based assay for total iron detection,and the effects of ferric ion (Fe3+) and ferrozine levels on the quantification of Fe2+ under wine conditions were also investigated.The results showed that the modified ferrozine assay wasestablished for the direct determination of total iron in wine,the standard curve exhibited a good linear relationship between absorbance and iron concentration from 0.25 mg/L to 2.00 mg/L (R2 =0.997 9) and the method detection limit was 0.011 5 mg/L,with the recovery rate of 94.31%~104.34%.Moreover,the total iron concentration determined by the modified ferrozine assay was in good accordance with that measured by the atomic absorption spectroscopy (AAS) in different winesamples.However,the presence of Fe3+ seriously interfered with the accurate measurement of Fe2+ in wine,and the optimized molar ratio of ferrozine to total iron was 7,with fitting accuracy ranging from 101.98% to 113.50% for Fe2+ determination.The assay was applied to some commercial bottled wines,and it was confirmed that Fe2+ was the dominant iron in wine,although the percentage of Fe2+ in red wines was much higher than that in white ones.In brief,the modified ferrozine assay was simple,accurate and reliable to determine total iron and Fe2+ in wine rapidly,and it can be widely used in the wine industry in future.【总页数】7页(P338-344)【作者】郭安鹊;张星星;张予林;董鑫;陈力维【作者单位】西北农林科技大学葡萄酒学院,陕西杨凌712100;西北农林科技大学葡萄酒学院,陕西杨凌712100;西北农林科技大学葡萄酒学院,陕西杨凌712100;西北农林科技大学葡萄酒学院,陕西杨凌712100;西北农林科技大学葡萄酒学院,陕西杨凌712100【正文语种】中文【中图分类】TS262.6【相关文献】1.二氮杂菲光度法连续测定水样中总铁及亚铁 [J], 孙本良;李洪刚;李春艳2.原子吸收分光光度法与1,10-二氮杂菲分光光度法测定水中总铁的比对试验分析[J], 刘楚文3.火焰原子吸收分光光度法与二氮杂菲分光光度法测定水体中总铁方法对比 [J], 张晋洁4.锑金精矿酸性电积工艺中电解液中总铁、Fe2+、Fe3+的含量测定 [J], 康钦科;龙志华5.菲咯嗪分光光度法测定水中的总铁 [J], 李媛;陈奇洲;欧国荣;梁军因版权原因,仅展示原文概要,查看原文内容请购买。
原子吸收光谱法(火焰)测定葡萄酒中铁的方法验证

第47卷第6期2626年11月酿酒LIQUOR MAKING文章编号:1662-+116(2626)66-6697-63V o L47.N q.6 Nov.,2626原子吸收光谱法(火焰)测定葡萄酒中铁的方法验证蒋祥飞,侯亚伟(安徽古井贡酒股份有限公司,安徽亳州236820)摘要:依据GB/T27417-2017(合格评定化学分析方法和确认指南》中方法验证相关的规定,对国家标准GB5009.90-2016(食品安全国家标准食品中铁的测定》第一法火焰原子吸收光谱法并验证其所涉及的测量范围、线性范围、检出限、定量限、精密度、正确度六个方法参数。
关键词:铁;葡萄酒q方法验证中图分类号:T0262.6q T0207.3文献标识码:%Determination of Iron in Wine by Atomic Absorption Spectrometry(Flame)JIANG Xiangfei,HOU Yawei(Anhui Gujing Gong Liquor Co.,Ltd.,Bozhou236820,Anhui,China)Abstract:According to the relevant provisions of the GB/T27417-2017conformity assessment chemical analysis methods and validation guidelines for method vesication,to the country Hove Standard GB5009.90-2016Determination of I^i in Food by the National Standard for Food Safety The first method,flame atomic absorption spectromet巧,was used to ver询the measurement range,linear range,detection limit,quantitative limit,precision and accuracy.Key words:iron;wine;method validation随着人民生活水平的不断提高,葡萄酒正在向型,健康型,型的,酒,为大喜欢的酒酒的中,离子超标的,酒生,如控的含量,酒的稳显得为酒中铁含量的照GB5009.90-201^食品安全国家标准食品中铁的吸收光谱其涉及的测量范围、线性范围、检出限、定量限、精密度、正确度六个参数!1#以确保分析数据的确性、科学性和严密1材料与方法1.1试剂除非另有说明,本方法所用试剂均为优级纯,水为GB/T6682规定的二级水。
果酒中铁含量的测定

果酒中铁含量的测定——邻二氮菲分光光度法测定铁1 实验目的(1)掌握邻二氮菲法测定铁的原理;(2)学会标准曲线的制作和样品的测定2 实验原理邻二氨菲( 又称邻菲罗琳) 是测定微量铁的一种较好的试剂。
在pH 2~9 的溶液中,试剂与Fe2+生成稳定的橙红色络合物,此红色络合物的最大吸收峰在508 nm 处,其吸光度与铁的含量成正比,故可比色测定。
3 试剂(1)铁标准储备液:准确称取4.9781g Fe(SO4)4·7H2O,溶于100ml水中,加5ml浓5mL H2SO4溶液微热,溶解后随即加入2%KMnO4至最后一滴红色不退色为止,加水溶解至1L,摇匀。
(2)铁标准溶液:取10ml铁标准储备液于100ml容量瓶中,加0.5ml硝酸溶液,定容。
(3) 邻二氮菲:0.15% 水溶液。
(新鲜配制):避光保存,溶液颜色变暗时即不能使用。
(4) 盐酸羟胺:10% 水溶液(临用时配制) 。
(5) NaAc 溶液:l mol/L。
(6) NaOH 溶液:l moI/L。
(7) HCl 溶液:1:1 水溶液。
4 操作步骤(1) 工作曲线的绘制在6 只50 mL 容量瓶中,用吸量管分别依次加入100 mg/mL 的铁标准溶液( 注意,是试剂2 不要错加成试剂1) 0.00 mL,0.20 mL,0.40 mL,0.60 mL,0.80 mL,1.00 mL,再分别加入10% 的盐酸羟胺溶液1 mL,0.15% 的邻二氮菲溶液2 mL,1 mol/L NaAc 溶液5 mL,以水稀释至刻度,摇匀。
在所用波长下,用l cm 比色皿,以试剂溶液为参比,测定各溶液吸光度,绘制工作曲线,并计算摩尔吸光系数。
(2) 铁含量的测定准确移取适当体积未知液,按工作曲线的测定步骤,测定其吸光度,从工作曲线上求出未知液中Fe的含量(mg/mL)。
注:由于本实验所使用的邻二氮菲、盐酸羟胺、醋酸钠、NaOH 等溶液,均为无色透明的水溶液,所以实验中所有参比溶液,均可使用蒸馏水。
红酒中微量金属元素的测定研究

毕业设计(论文)题目红酒中微量金属元素的测定研究系(院)化学与化工系专业化学工程与工艺班级2010级跨校化工班学生姓名赵迎春学号1012100119指导教师解胜利职称讲师二〇一二年六月独创声明本人郑重声明:所呈交的毕业设计(论文)是本人在指导老师的指导下独立进行研究工作所取得的成果成果不存在知识产权争议。
尽我所知除文中已经注明引用的内容外本设计(论文)不含任何其他个人或集体已经发表或撰写过的作品成果。
对本文的研究做出重要贡献的个人和集体均已在文中以明确方式标明。
本声明的法律后果由本人承担。
作者签名:二〇一二年六月十八日毕业设计(论文)使用授权声明本人完全了解滨州学院关于收集、保存、使用毕业设计(论文)的规定。
本人愿意按照学校要求提交学位论文的印刷本和电子版同意学校保存学位论文的印刷本和电子版或采用影印、数字化或其它复制手段保存设计(论文);同意学校在不以营利为目的的前提下建立目录检索与阅览服务系统公布设计(论文)的部分或全部内容允许他人依法合理使用。
(保密论文在解密后遵守此规定)作者签名:二〇一二年六月十八日红酒中微量金属元素的测定研究摘要红酒是一种滋味美好的饮料,其中含有糖类、无机酸、果胶质、微量元素及几十种氨基酸等人体所需要的营养物质,具有很高的营养价值和保健作用。
但是红酒中的微量金属元素过量会对人体造成一定的伤害。
因此,建立测定红酒中微量元素含量的方法非常重要。
本文使用直接蒸发、直接消解、高氯酸-硝酸混合消解、双氧水-硝酸混合消解等多种红酒预处理方法,采用火焰原子吸收法测定了红酒中的Pb、Cr、Cu、Fe四种元素的含量。
实验得出以下结论:Cr、Fe、Pb、Cu含量依次减少;采用双氧水-硝酸混合消解方法的精密度(RSD)及加标回收率在四种消解方法中最为准确;直接蒸发方法预处理酒样时,蒸发温度为70℃所得结果精密度(RSD)和加标回收率较好。
关键词:火焰原子吸收光谱法;红酒;金属元素;消解The Research and Determination of Trace MetalElements in Red red wineAbstractRed wine is a taste good drink, which contain carbohydrates, inorganic acid, pectin, trace elements and dozens of amino acids and so on, all these are the necessarily nutrients for the human body. So red wine has high nutritional value and health care function. But excessive trace metal elements in red wine can cause certain harm to human body. Therefore, establishing a method to determine the trace elements content in red wine is very important.In this paper, a variety of red red wine pretreatment method (direct evaporation, direct digestion, high chlorine acid-nitric acid hybrid digestion, hydrogen peroxide -nitric acid hybrid digestion)had been used. Flame atomic absorption method is applied to study and determine the Pb, Cr, Cu, Fe element content in red wine.The experiment draws the following conclusions: The content of Pb, Cr, Cu, Fe is progressively less; The hydrogen peroxide-nitric acid hybrid digestion method's experimental results are more accurate of all the methods; When the evaporation method of liquor samples pretreatment are adopt, the results of 70℃is precision and the recovery results are good.Key words: Flame atomic absorption spectrometric method; Red red wine; Metal elements; Digestion目录引言 (1)第一章概述 (2)1.1 红酒中金属元素的来源 (2)1.1.1来自环境条件 (2)1.1.2来自红酒的制作、运输和贮藏 (2)1.2原子吸收前处理方法 (2)1.2.1微波消解 (2)1.2.2在线富集 (3)1.2.3浊点萃取 (3)1.2.4悬浮液进样 (3)1.3红酒中金属元素的分析技术 (3)1.3.1原子吸收光谱法(AAS) (3)1.3.2分光光度法 (4)1.3.3荧光分析法 (4)1.3.4等离子体发射光谱法(ICP-AES) (4)1.3.5质谱法(MS) (5)1.4本文的研究内容与目标 (6)第二章实验部分 (7)2.1材料 (7)2.1.1实验材料 (7)2.1.2试剂与仪器 (7)2.1.3实验前准备 (7)2.2配制标准溶液 (7)2.3各个灯的工作参数 (7)2.4各元素标准曲线 (8)2.5精密度及加标回收率的计算 (10)第三章不同前处理方法测定红酒中的金属元素 (11)3.1直接蒸发 (11)3.1.1实验过程 (11)3.1.2实验结果 (11)3.2.直接消解 (12)3.2.1实验过程 (12)3.2.2实验结果 (12)3.3高氯酸-硝酸混合消解 (13)3.3.1实验过程 (13)3.3.2单因素实验 (13)3.3.3正交实验 (15)3.3.4验证试验 (17)3.4.双氧水-硝酸混合消解 (17)3.4.1实验过程 (17)3.4.2单因素实验 (18)3.4.4实验结果 (19)3.5四种消解方法的比较 (20)结论 (21)参考文献 (22)谢辞 (23)引言红酒是一种低酒精度的饮料,有丰富的营养物质。
219474459_不同前处理-GFAAS法测定葡萄酒中铜、铁元素含量的技术研究

SINO-OVERSEAS GRAPEVINE & WINE不同前处理-GFAAS 法测定葡萄酒中铜、铁元素含量的技术研究蒋娟1,2,刘宇航1,梁艳英1,2,3,张予林1,2,3*(1. 西北农林科技大学葡萄酒学院,陕西杨凌 712100;2. 陕西省葡萄与葡萄酒工程技术研究中心,陕西杨凌 712100;3. 西北农林科技大学合阳葡萄试验示范站,陕西合阳 715300)摘 要:试验采用湿法消解法、干法消解法和直接稀释法对红白葡萄酒进行消解前处理,同时进行加标回收试验,分析不同前处理方法测定Cu 、Fe 元素的准确性,以确定石墨炉原子吸收光谱法(GFAAS )的最佳测定条件。
结果表明:利用石墨炉原子吸收光谱仪测定葡萄酒中Cu 和Fe 时,标准曲线线性关系良好,最佳灰化温度均是600 ℃,最佳原子化温度均是2300 ℃,检出限分别是0.58 μg·L -1和1.15 μg·L -1,定量限分别是1.94 μg·L -1和3.85 μg·L -1。
另外,湿法消解法操作快速简单,精密度和准确度较高,是用石墨炉原子吸收法测定葡萄酒中Cu 和Fe 元素含量较为理想的前处理方法。
关键词:石墨炉原子吸收法;湿法消解法;干法消解法;直接稀释法;铜;铁;葡萄酒 中图分类号:TS262.61 文献标志码:A DOI :10.13414/ki.zwpp.2023.04.011收稿日期:2022-09-15基金项目:国家重点研发计划(2019YFD1002500);财政部和农业农村部:国家现代农业产业技术体系(CARS-29-zp-6) 西北农林科技大学试验示范站(基地)科技成果推广项目(TCZX2020-36)作者简介:蒋娟(1987—),硕士,主要从事葡萄酒分析与检验研究。
E-mail:*******************.cn*通信作者:张予林(1975—),副教授,主要从事葡萄酒分析与检验研究。
原子吸收分光光度法测葡萄酒中的铁

原子吸收分光光度法测葡萄酒中的铁一、引言原子吸收分光光度法是一种常用的分析技术,广泛应用于食品、环境、药物等领域。
本文将探讨如何使用原子吸收分光光度法来测定葡萄酒中的铁含量。
二、原子吸收分光光度法的原理原子吸收分光光度法基于原子吸收光谱的原理,通过测量样品中特定元素的吸收光谱来确定其浓度。
在本实验中,我们将使用原子吸收分光光度法来测定葡萄酒中的铁含量。
2.1 原子吸收光谱原子吸收光谱是一种特定元素在特定波长的吸收光谱。
当样品中的特定元素处于激发态时,会吸收特定波长的光线。
通过测量吸收光线的强度,可以确定样品中该元素的浓度。
2.2 原子吸收分光光度法的步骤原子吸收分光光度法的步骤主要包括样品制备、原子化、光谱测量和浓度计算。
1.样品制备:将葡萄酒样品进行适当的处理,如稀释、过滤等,以获得适合测定的样品。
2.原子化:将样品中的铁原子化为气态原子。
常用的原子化方法包括火焰原子吸收光谱法(FAAS)和电感耦合等离子体原子发射光谱法(ICP-AES)。
3.光谱测量:将原子化后的样品通过光谱仪进行测量。
选择适当的波长进行测量,并记录吸收峰的强度。
4.浓度计算:根据样品的吸光度和标准曲线,计算出样品中铁的浓度。
三、测定葡萄酒中铁的步骤3.1 样品制备1.取适量葡萄酒样品,并将其稀释至适合测定的浓度范围。
2.使用过滤器将样品进行过滤,以去除悬浮物和杂质。
3.2 原子化1.将样品送入火焰原子吸收光谱仪进行原子化。
调整火焰的温度和气体流量,以获得最佳的原子化效果。
2.记录原子化过程中的吸光度变化。
3.3 光谱测量1.选择合适的波长进行测量。
常用的波长为248.3 nm。
2.在光谱仪中设置好波长,并进行测量。
记录吸光度的数值。
3.4 浓度计算1.制备一系列标准溶液,浓度从低到高。
2.分别测量标准溶液的吸光度,并绘制标准曲线。
3.根据样品的吸光度和标准曲线,计算出样品中铁的浓度。
四、实验注意事项1.实验操作要严格按照操作规程进行,避免误差的产生。
原子吸收分光光度计测定葡萄酒中铁含量的两种方法比较

原子吸收分光光度计测定葡萄酒中铁含量的两种方法比较姜忠军;王永杰
【期刊名称】《酿酒科技》
【年(卷),期】2004(000)002
【摘要】比较了利用原子吸收分光光度计测定葡萄酒中铁元素含量的两种方法--标准浓度法与标准加入法,测定结果的相对标准偏差(n=6):标准浓度法为2.8%,标准加入法为2.1%;回收率范围分别为119.93%~146.30%和101.33%~103.30%;线性范围均为0~12 mg/L.确定了更为准确、稳定、快速的标准加入法作为原子吸收分光光度计分析葡萄酒中的铁元素含量的最佳方法,并可将该方法推广到其他元素的测量中使用.
【总页数】2页(P89-90)
【作者】姜忠军;王永杰
【作者单位】张裕集团有限公司技术中心,山东,烟台,264001;张裕集团有限公司白兰地公司,山东,烟台,264001
【正文语种】中文
【中图分类】TS262.6;TS261.7;O617.31
【相关文献】
1.用两种方法测定葡萄酒中甲醇含量的比较 [J], 谭桂华
2.原子吸收分光光度法测定葡萄酒中铁含量的方法验证 [J], 蒋祥飞;张利
3.邻菲啰啉比色法测定葡萄酒中铁含量实验方法改进 [J], 魏冬梅;蒋娟;梁艳英;傅
旭阳
4.两种方法评定生活饮用水中铁含量不确定度的比较 [J], 汪锋;黄显达
5.两种方法评定生活饮用水中铁含量不确定度的比较 [J], 汪锋;黄显达
因版权原因,仅展示原文概要,查看原文内容请购买。
葡萄酒中铁含量测定

葡萄酒中铁含量测定一、实验目的1、熟练掌握分光光度计的操作方法2、掌握用邻二氮菲分光光度法测定微量铁的原理和方法3、学习吸收光谱分析法的实验条件的选择二、实验原理葡萄酒是以新鲜葡萄为原料发酵而成的酿造酒。
在酿造过程中,葡萄浆果里的糖经酵母菌的作用,分解为酒精及其副产物。
葡萄浆果中的其他成分(如单宁、色素、芳香物质等)以不变化的形式转移到葡萄酒中,因而葡萄酒营养丰富。
葡萄酒中含有铁,而铁又是造成葡萄酒变质的重要因素,因此铁的测定就显得格外重要。
葡萄酒中的铁几乎全部处于络合状态,以铁和亚铁络合物存在,这些络合物一般是比较稳定的,但是也能电离出少量的Fe3+和Fe2+。
测定含量时,首先需要还原剂盐酸羟胺把Fe3+还原为Fe2+,与邻啡罗啉作用生成红色螯合物,其颜色的深浅与铁含量成正比,用分光光度法进行铁的测定。
显色反应条件是影响测定灵敏度和准确度的主要因素。
显色反应条件包括显色剂的用量、溶液酸度、显色反应时间和反应温度及干扰物质等,均需一一研究以便制定最佳分析方案。
三、实验材料分光光度计,浓硫酸,过氧化氢溶液,氨水,盐酸羟胺溶液(1OOg/L),邻啡罗啉溶液(1.2g/L),铁标准溶液(1O0mg/L),铁标准使用液(1Omg/L)。
四、实验方法及数据处理1、测定条件的研究1.1波长的选择取10.00mL浓度为10mg/L的铁标准使用液于50mL容量瓶中,加1OOg/L盐酸羟胺溶液1ml,摇匀,放置2min,然后加入5ml乙酸一乙酸钠溶液,2mL1.2g/L邻啡罗啉溶液,然后加蒸馏水至刻度,摇匀。
用1.00cm吸收池,以试剂空白作参比,于各种波长处,采用721分光光度计测定吸光度。
然后在不同的波长下测定其吸光度值,绘制吸收光谱曲线(波长为横坐标,吸光度为纵坐标)。
4404604805005205405600.050.100.150.200.250.300.350.400.45A b s o r b a n c eW avelength / nm图一 不同波长下的吸光度1.2 显色时间的测定装入1.00吸收池的上述显色试液,在 510nm 波长下,以纯水为参比溶液,测定显色反应时间分别为 5min 、10min 、20min 、30min ,40min 、1h 时显色产物的吸光度,确定显色反应时间。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
葡萄酒中铁含量的测定---邻菲罗啉比色法
操作指南(180min内完成所有考核内容)
原理:
样品经处理后,试样中的三价铁在酸性条件下被盐酸羟胺还原成二价铁,与邻菲啰啉作用生成红色螯合物,其颜色的深度与铁含量成正比,用分光光度法进行铁的测定。
(于480 nm波长处)
1、准备要求:
(1)仪器的准备
见附录1
(2)试剂的准备
见附录1
(3)仪器的洗涤
1)所用玻璃仪器均需按照洗涤要求清洗干净;
2)所用水为蒸馏水。
(4)仪器的检查
考核前应认真检查、核对仪器、做到仪器完好、无缺。
2、考核内容:
(1)考核要求
1) 铁标准使用液(1mL溶液含有10μg铁)的配制
吸取 10.00mL铁标准贮备液于100mL容量瓶中,用0.5%硝酸溶液稀释至刻度,此溶液每毫升含10μg铁。
2) 铁标准系列的配制
吸取铁标准使用液 0.00,0.40,0.80,1.00,1.40mL(含 0.0,4.0,8.0,10.0,14.0μg铁)分别于五支25mL比色管中,补加水至10mL,加5mL乙酸-乙酸钠溶液、1mL盐酸羟胺溶液,摇匀,放置5 min后,再加入1mL 邻菲啰啉溶液,然后补加水至刻度,摇匀,放置5 min,备用。
该系列用于标准工作曲线的绘制。
3)标准工作曲线的绘制
在480nm波长下,测定标准系列的吸光度。
根据吸光度及相对应的铁浓度绘
制标准工作曲线(或建立回归方程)。
4)样品处理(同时以蒸馏水替代酒样做空白试验)
吸取酒样 1.00 mL 于 50 mL 凯氏烧瓶中,置电炉上缓缓蒸发至近干,取下稍冷后,加0.5mL 浓硫酸、1 mL 过氧化氢,加热消化。
如果消化液颜色较深,继续滴加过氧化氢溶液,直至消化液无色透明。
稍冷,加10 mL 水微火煮沸 3 min ,取下用自来水淋流冷却。
同时做空白试验。
5)试样的测定
将试样及空白消化液用纯水分别洗入25mL 比色管中(注意:洗涤用水的用量要非常少),在每支管中加入一小片刚果红试纸,用氨水(1.2mL 左右)中和至试纸显蓝紫色(pH4~5),然后各加5mL 乙酸-乙酸钠溶液,加1mL 盐酸羟胺溶液,摇匀,放置5min 后,再加入1mL 邻菲啰啉溶液,然后补加纯水至刻度,摇匀,放置5 min ,在分光光度计上于480nm 波长处测出的吸光度,从标准工作曲线上查出铁的含量(或用回归方程计算)。
6)结果计算 V
m m X 0
-=
式中:X ——样品中铁的含量,mg /L ;
m ——测定用样品中铁的含量,μg ; m 0——试剂空白液中铁的含量,μg ; V ——取样体积,mL 。
所得结果应表示至一位小数。
7)测定结束后,填写上交分析测试报告单。
(2)安全文明操作
1)正确执行实验室安全操作规程。
2)遵守实验室规则,认真、如实记录实验数据。
3)保持实验台面及周围环境整洁,仪器、用品摆放整齐。
附录1:
实验项目名称:葡萄酒中铁含量的测定-邻菲啰啉比色法。