8路同步控制器SC-280说明书

合集下载

诺贝瓦尔2800-2026型模拟量总计 批次控制器使用手册说明书

诺贝瓦尔2800-2026型模拟量总计 批次控制器使用手册说明书

Nokeval No 031002ManualModel 2800-2026Totalizer / Batch controllerfor analog inputsContentsRate / Batch controller 2026 for analog inputs (3)Dimensions (4)Front panel indicators and buttons (5)Configuration (5)Reset of configuration parameters (5)Setting of alarm value (5)Setting of alarms (5)Selection of input (7)Alarm functions (8)General description (8)Alarm card connections (8)Alarm settings by front panel keys (8)Selection of alarm card and relay-function settings (9)Main menu (9)Shifting in menu (9)Minimum and maximum value memory (10)Reset memeory (10)Setting of secret codes (Programming stage/ alarms) (10)Terminal connections (11)Current intput 0/4..20 mA (11)Voltage input 0-10V (11)2-wire 4-20 mA (11)Field displays 2800 construction (12)2800-2026 Rate / Batch controller for analog inputs • Input signal 0/4-20 mA, mV or 0-5/10V• Cumulative counter (quantity)• Mass flow display according to weighing• Up or down count• Rate/batch operation• 6 digit display• Counter non-volatile memory• Scalable display• One alarm level for batch function• Front panel protection IP65• Sensor supply 24 VDC, max. 150 mA• Power supply 90..240 VAC or 12..32 VDCCounter 2800-2026 assorts as volume counter or Batch contoller for flowmeters. Up or down counter has 6-digit red or green display. Display scaling indicates flow rate corresponding to one V/mA in time unit. Display memory (optional) stores calculated value for one week after power brake. You may use the counter as a batch controller by setting alarm value corre-sponding desired batch volume. Optional output relay changes its stage when alarm level is reached. You can start new count by resetting counter by remote contact or configure unit to stars automatically new batch. You may also determine start level (START)from which you can count down (empty) or up (filling). Configuration stage gives user the possibility to specify what values can be seen in display. Alternatives are rate-of-change (flow rate), totalizer (total flow) or scaled value of the input. User may change the display between two alternatives by ★-key .Calculated amount is set by front panel keys. Nokeval makes counter also for pulse sensors, model 2800-2061, separate data sheet available.Technical specifications:Input0..20 mA, 4..20 mA0..5, 0..10V20, 50, 100, 1000 mVDisplay scaling On whole display rangeInput resistance current 50 ohmvoltage 1 MohmAccuracy0.03% FSLinearity0.005% FSSupply for sensor24 VDC, max. 150 mADisplay scalingNumber of digits per one mA in time unit. Time setting in secondsCount directionUp or down. Direction changed by converting input signal.Mass flow display of weighing sensor alteration Fillng or emptying rate container according to weighing sensor. Counts alternation between two measurement in time unit. Display e.g. ton/h (rate-of-change = Flow). Function of output relayAlarm relay is set by front panel keys. Only one relay is available for totalizer function, batch controller. Dosage function (batch)When set point is reached output relay is activated and will be reset only by remote reset and that resets at the same time the display. Dosage can be started from any value up- or downwards. Output relay is mounted to additional slot. Relay contacts max. 240 VAC, 1 A, alterna-tively logic relays, 60V, 0,5 A.Display memory: Add- on card 2000-MEM stores display for one week in case of power brakeDisplay resetAutomatically according to the alarm border or by outside key from 2000-MEM card.GeneralInput filter Digital, freely adjustableAD-conversion16 bits (64 000) Temperaturestab.0,0004 %/°CDisplay6-num. bright red LED,digit height 20 mmPower supply 85...240 VAC or 12...30 VDC/ 24VAC Power demand 3 VAProtection IP65Weight 500 gType specification2800-2026-REL2-MEM-24VDCInput card 2026Relay card REL2Memory card MEMPower supply12 -32 VDC, 24VACor 85-240VACOptional add-on cards:Memory2000-MEM (for slot B) Relay card for 2 relays2000-REL2 (for slot C)Mother board has two slots (B and C) for add-on cards.Front panel indicators and buttonsWith ▲▼-keys You can move on or changenumbers and values in programming menu.pressing the ★can be selected in programming stage:(See closer in chapter programming)1. Rate-of-change value (flow)2. Scaled display (function de_nor selected)1. Scaled display (e.g. 4..20 mA = 0..100,0%)2. Rate-of-change value (function nor_de selected)1. Totalizer2 Scaled display (function to_nor selected)1. Scaled display2. Totalizer (function nor_to selected)Conf-light indicates program stageConfigurationYou can enter configuration stage by pressing two seconds ▲ and ★-keys at same time. In program stage f. ex. scaling of display, sensor selection and alarm mode are chosen.See closer in chapter programming.Reset of configuration parametersForgotten secret code may be reset by connecting power supply and pressing ▲,▼ and ➤ -keys at same time. Then you can enter configuration stage by keys ▲▲▲▲▲▲. Change secret code and exit by SAVE .Checking of alarm valueFirst pressing of ➤ key shows setpoint of alarm one (A1), correspondingly second pressing shows setpoint of alarm two (A2) etc. Alarm indication light blinks in display informing that alarm level is displayed (if you do not touch keys during 8 seconds display returns to normal state automatically).Preventing of entering alarms (secret code)If you have set secret code for alarms you must feed it before you can change alarms (see chapter ”settings of secret codes” Page 8).Change of alarm valueSee chapter ”Alarm settings by front panel key”Page 8.+FiLt dISP PEAK CALib SEtCodConfiguration menu functionsScaled displaye.g. 4..20 mA = 0..100,0%Rate-of-change (Flow/time unit)Scaled display Totalizerdisplay with *-buttonStart value is set to zero.Press and hold ➤-button for 2 seconds. See also remote reset, page 10.Digital filter for input signal (damping) selectable 0,01...1.0 (1.0= no filter)0.2 = factory setting = 2 new and 8 old values1= display update time 15/s. 7= 2/s. (average of 7 measurements)Min/max function: On=enabled, Off=disabled Indicators M1=min, M2=max For factory settingsSecret code settings ▼ (▲ back): ALCod= Code for alarm settingsCFCode= Code for configuration. See also section 'Secret code setting.You can enter configuration stage by pressing two seconds ▲ and ★ keys at ★-key.Selection of input+Units accept input from below list. Move with arrows into desired input and select with *-key. Default selection is 4-20 mA. You can enter configuration stage by pressing two seconds ▲ and ★ keys at same time.Save with ➤ key and exit from configuration Alarm level setting. See also section 'Alarm functions'.Undo changes and exit from configurationAlarm level setting. See also section 'Alarm functions'.* and Unipolar **Slot b Slot c SAVE UndoExample downwards countingTypical downwards counting application is emptying of container. Normally in the container has 1000 litres of water. When you empty it, it is necessary to know how much water is discharged. In the bottom of container is flow meter, which has a scaling of 0..100 litres / min and output signal of 4..20 mA. Set follows: Lo = 0,Hi = -100, Start = 1000, Time = 60. (By Hi-value +100 counting would start upwards).General descriptionPanelmeter default relay card is REL2. In comissioning you have to ensure the hardware setup before programming. You can find description of alarm card and its place on meter plate (def slot C).When basic selections are done in program stage, normal use by front panel keys is very simple .Alarm cards:REL 2 =two relays with changeable contacts (grey connector colour).Grey connectors are designed for mains voltage 230 VAC, 2A and green connectors for 36 VDC, 100 mA.Alarm functions(Line 2 = relay 2)Select Slot CMeter has versatile alarm functions. In initial settings you can select first type of alarm card (default REL2)into slot C. There are two relays but only one of relays is available. When initial settings have been made user can easily set alarm levels by front panel keys (see chapter ”alarm functions” Page 8). You can prevent entering to alarm change stage by secret code Shifting in menuYou shift in menu to next level (to right) in programming stage by ➤-key. By ★ -key you return to previous level or to main menu. Only one relay (line 1 or 2) can be used for alarm or batch function.What starts the alarm (Line):Norm AL Scaled value without time unit tot AL Totalized value or flow rate / time unit Counter auto reset (Loop):ON Counter reset and new start withoutmanual resetOff Manual reset with external buttonFor Hold input (I/O-line 3 in slot b):Off = (default) relay changes its stage only when batch item is reached (alarm value)Selection of alarm card and relay-function settingsHysteresis selectionA1-A4AL Lo = Low level AL Hi = High level Alarm Reset:Manually from input line (slot b)or automatic Relay direction:No=normal open Nc=normal closedUnit remembers which card is in use and skips direct to selection of relay number (line 1). You can select new card in setup-point by holding down ▲ or ▼-keys 3 seconds. Point OFFand then ★ -key excludes the card from use. Front panel indication lights A1..A4 correspond to relay (line) numbers 1..4. Serial = serial card, see chapter 'serial output RS-485/RS-232'.Slot B tai Slot C = Card slot B or C(3 sec.)No alarmsRemote reset and hold function (totalizer)GENERAL DESCRIPTIONIn addition to automatic reset you can reset also by remote contact (optional). Contact is connected to add-card 2000-MEM, which acts also as display memory. Display is stored for one week without power. Counting of display can be stopped by Hold function from I/O-line 3 or 4 installed to Slot B.PROGRAMMINGIn programming state you select Slot b. By the ➤ -key you enter Setup-menu in which you select card 2 (I/O-card). Then you move to next menu by ➤-key, in which you select Line 3 or 4. In next menu you select Reset or Hold of counter. After reset selection you choose function direction of reset contact (opening or closing). You can return to main menu by ★-key.In the Hold menu you can select opening or closing contact of hold input that stops counting. If you need to use relay together with hold function, see page 9. The reset and hold functions (inputs) can be closed by selecting OFF menu only.OpeningcontactClosingcontact Select Card2(default)11Minimum and maximum value memoryMeter has min. and max. memory as standard. This function must be selected in programmimg stage,parameter PEAK =ON.You can glance values by ➤-key. When you press the ➤-key indication lights, above display, turns on in following order:1.A1alarm level 2.A2alarm level 3.A3alarm level 4.A4alarm level 5.M1Minimum value memory 6.M2Maximum value memory 7.Back to measuring stage Reset memeoryYou may reset memory when you press ★-key when display shows memory in question, either M1 or M2.with ★ -key when indi-cator M1 or M2 lits.Setting of secret codes (Programming stage/ alarms)In Main menu positionSETCod press ➤ -key and move on to selection stage.Secret code:ON = enableOFF = disable (default)ALCode = Secret code setting for alarmsCFCode = Secret code setting for ProgrammingYou set secret code by pressing six time keys (1-4) in wished order (lines goes forward in display). Setting must be repeated in same order before new setting is accepted.Example: Press one after another keys ▲ ▲ ★➤▲▲and once more ▲ ▲ ★➤▲▲. You may think the keys as numbers from left to right 1,2 3,4 in order to helprecording and remembering.Select secret code mode:CFCode programming ALCode for alarms1234e.g.A1-A4 lits if alarm card(s) is (are) fitted.Input code ▲ ▲ ★➤▲▲ and once more.Example number value would be 113411.12Voltage input 0-10VSensor supply24 VDC, max 150 mAPower 90.....230 VAC, Gray connector12.....32 VDC, 24VAC, green connector (no polarity)Terminal connectionsCard slotsSlots B and C for optional cards.Sensor supply 24 VDCmax. 150 mA+-2-wire 4-20 mA input2-wire transmitter0/10 V input requires shortcut jumper J1 to position 1-2, for other inputs shortcut 2-3.Input card 2021-MUCurrent intput 0/4..20 mA (active transmitter)Factory settings (2-3)0/10V inputCurrent Inputs Relays ratings:max. 230 VAC 2A (A1 is default for totalizer function)Colour codes:Gray for 230 VAC, Green for 24 VDCJumper 3-4Jumper 3-4。

KL-280G/H 吉隆中文说明书1.16

KL-280G/H 吉隆中文说明书1.16

1.5 熔接机的待机界面说明 ……………………………………………………… 7
2 基本操作 …………………………………………………………………………8 2.1 电源模块说明 …………………………………………………………………8 2.2 交流供电操作 …………………………………………………………………8 2.3 电池供电操作 …………………………………………………………………9 2.3.1 电池电量检查………………………………………………………………9 2.3.2 电池充电 …………………………………………………………………10 2.3.3 电池使用注意事项 ………………………………………………………10 2.3.4 电池危险警告 ……………………………………………………………11 2.4 开机和关机 ……………………………………………………………………12 2.5 显示器亮度调节 ………………………………………………………………13 2.6 套光纤热缩管 …………………………………………………………………14 2.7 制备光纤端面 …………………………………………………………………14 2.8 放置光纤 ………………………………………………………………………19
附录 A 熔接机软件版本升级注意事项 …………………………………………77 附录 B 保修期限及条件 …………………………………………………………78 附录 C 联络方式 …………………………………………………………………79
南京吉隆光纤通信股份有限公司 1. 概述
感谢您选择南京吉隆光纤通信股份有限公司的产品。 本手册将详细介绍公司 最新产品 KL-280G/H 光纤熔接机的特点和使用方法。该机采用了高速图像处理 技术和特殊的精密定位技术, 可以使光纤熔接的全过程在 9 秒内自动完成。它外 形小,重量轻,而且操作简单,熔接速度快,熔接损耗小,特别适用于电信、广 电、铁路、石化、电力、部队、公安等通信领域的光纤光缆工程和维护以及科研 院所的教学与科研。为了更准确地完成熔接操作,请详细阅读本说明书。

TOP-PWR8电源控制器说明书

TOP-PWR8电源控制器说明书

TOP-PWR8电源控制器说明书TOPTRONProgrammable Power Control System可编程电源控制系统⽤户⼿册USPWR-8⼋路电源控制器在使⽤本系统前,请详细阅读本说明书.并请保管好该⼿册⼀、设备使⽤注意事项为确保设备可靠使⽤及⼈员的安全,请在安装、使⽤和维护时,请遵守以下事项:1、在设备安装时,应确保电源线中的地线接地良好,请勿使⽤两芯插头,。

确保设备的输⼊电源为220V50Hz的交流电。

2、当电源开关处于关的状态时,机箱内的电源线仍然带电,⾮专业⼈员请勿随意打开机箱,以免发⽣触电事故。

3、不要将电源控制器设备置于过冷或过热的地⽅。

4、电源控制器在⼯作时会发热,因此要保持⼯作环境的良好通风,以免温度过⾼⽽损坏机器。

5、阴⾬潮湿天⽓或长时间不使⽤时,应关闭设备电源总闸。

6、⾮专业⼈⼠未经许可,请不要试图拆开设备机箱,不要私⾃维修,以免发⽣意外事故或加重设备的损坏程度。

⼆、绪⾔感谢您购买和使⽤本公司的产品。

在使⽤本机前,请细阅这本⽤户⼿册,以便能正确使⽤。

并且请妥善保存这本⼿册,万⼀有不了解或故障时,这本⼿册会带给您很⼤的帮助。

⼋路电源控制器是最新开发的⾼科技产品。

此产品专为各类多媒体中央控制器量⾝定制,通过机器内置地址码开关,最⾼可以级连256台电源控制器。

三、本机特点:采⽤国际通⽤RS-232控制⽅式,可以兼容TOPTRON(拓创)、美国快思聪、美国AMX中控和其他品牌中控或第三⽅控制设备;机器内置220V电源供电,不需要另配电源;内置DIP地址码开关,按不同系统需要可以级连多台;内置⼋路进⼝30A⼤功率继电器模块,每路功率可达1200W;电源接⼝端有常开和常闭端,可以和其他控制模块做联动功能;内置⼆路RS-232接⼝,⽅便多台电源控制器连接。

四、通讯协议波特率: 9600 数据: 8 BITS 奇偶:⽆停⽌位: 1 BIT协议定义:起始码地址码继电器通道操作码结束码A B C D E协议解析:A为起始码:FFH (注:FFH中的H仅为表⽰16进制格式,并⾮填⼊值)B为设备地址码:00-FFH,B=00H为出⼚默认地址码,在通电时先按住KEY1,2,3,可设置出⼚默认地址码为0X00 C为继电器通道号:00-08H,C=0x00时,本电源控制器8个端⼝全开,或者全关D为操作码:1、当操作码D=FFH且C=0x00时,将地址码为B值。

德瑞斯参数功能介绍6(34-69)

德瑞斯参数功能介绍6(34-69)
400V 1~500V
200V 5~250V
5.00~上限频率
P.024~P.021
P.025~100.0 %
P.024 V/F 频率点 2
P.026~P.022
P.025 V/F 电压点 2
P.027~P.023
P.026 V/F 频率点 1
0.0~P.024
P.027 V/F 电压点 1
P.019~P.025
P.028 保留
P.029 端子电压 VI1 输入下限
0.0V~[P.030]
P.030 端子电压 VI1 输入上限
[P.029]~10.0V
P.031 端子电压 VI1 输入增益

拟 量
P.032 端子电压Ⅵ2 输入下限
0.01~10.00 -10.0V~[P.033]
脉 冲
\
P.033 端子电压Ⅵ2 输入上限
220
50.00Hz × 21
0.0
× 22
0.0
× 23
0.0
× 24
0.0
× 25
0.0
× 26
0.0
× 27
28
0.0V 10.0V 1.00
0.0 10.0 1.00 0.0
0
√ 29 √ 30 √ 31 √ 32 √ 33 √ 34 √ 35 √ 36
0.20
√ 37
4.0mA √ 38
DRS2800 系列使用手册
0.0~12.0V
0.0~P.054
P.054 模拟输出 A02 上限
0.0~12.0V
P.055 保留
0:控制端闲置
输入端子 P.056 (0~28)
X1
功 能 选 择 1:多段速控制端子 1 2:多段速控制端子 2

MAO-280手操器说明书

MAO-280手操器说明书

MAO-280后备手操器说明书概述:MAO-280M系列后备手操器能与各种DCS、VVVF、PLC、PC、RTU等控制系统和调节单元同阀门执行机构变频器配合使用。

具有启/停供电、手动硬手操、手动自动的转换等功能,对输入信号进行隔离处理,有很好的抗干扰能力。

也可接在各种调节器之后作备用仪表,一旦调节器失效,可由本控制器进行手动操作,并可取代伺服放大器直接驱动阀门。

本操作器有二路模拟量输入(可任意设定)(调节器输入,位置反馈输入),二路模拟量输出(可任意设定)(给调节器位置反馈,控制输出),二路开关量控制输入(自动/手动指示,启/停状态指示),二路开关量控制输出(自动/手动开关信号,启动/停止开关信号),可适用于各种测量控制场合。

采用国际标准开孔尺寸(66+1.0mm×66+1.0mm),真正做到小型化和标准化。

仪表具有高稳定性和高可靠性。

外形尺寸(宽×高×长=72mm×72mm×120mm)。

通过ISO9001国际质量体系认证,品质可靠。

MAO系列手操器特点:●长寿命,高可靠:该手操器采用英国多圈旋钮寿命长,一改原上下按键式的手操器,不耐用(工作不到一年,按键即损坏,薄膜式按键更是使用的时间短)。

该手操器属РоссияM280系列产品。

表内元件数量少故障率低,质保期长18个月,●安装和操作简便:安装采用盘面安装方便美观,可安装于任何仪表操作柜,电气柜上以及DCS桌面手操屏。

使用旋钮即刻调节,、非常适合变频器的调整(启动时慢速调、高速时快速调)。

并设有对设备的启/停开关,便于紧急故障处理。

●信号有多种配置:提供了现在国际常用的基本信号;4-20mA 、1-5V、0-10mA、0-10V、正反开关信号等。

●可与各种控制系统连接:可与DCS、PLC、PC、RTU、VVVF、及软件PID、进行连接,实现后备手操功能(当以上控制系统有问题时可快速切换到该手操器上手动调节。

控制器的使用说明书

控制器的使用说明书
˄ᇓ੶ᄁ࡙঩፯ˈჱ฀ขᏀᅲ˅
控 制 器
机种一览 24V 触摸面板
网关单元
简易绝对 型单元
RoBoNET
ด‫ވ‬፺ RCS2 Ⴜள / ‫ܠ‬፺঩ᄚ༇ / ፊღཔ࠵ด‫ވ‬፺
మ‫ݢ܌‬େ Ȕᄲख˖CB-RCC-MAɕɕɕȕ ‫׭‬Ꮃ 1m/3m/5m ֦ᆻቂ‫ݢ‬େ‫د‬ጐ P424
‫ף‬బධ‫ݢ‬େ Ȕᄲख˖CB-RCS2-PAɕɕɕȕ ‫׭‬Ꮃ 1m/3m/5m ֦ᆻቂ‫ݢ‬େ‫د‬ጐ P424
对于形状相同但是孔眼位置稍有不同的多个工件的场合,可以通过使用同一位置 No. 的移动指令,但是切换品种编号的 方式予以应对。
定位模式
2 轴独立模式 2 轴控制器时,可以分别指示各轴进行动作。
示教模式
DS-S-C1 兼容模式
可利用外部信号移动滑块(拉杆),将停止位置写入位置数据。 当使用了 DS-S-C1 控制器时,无需变更上位程序,可以直接替换控制器。※ 与驱动轴之间没有兼容性。
2m
5m
0.2m
‫ ܕ‬RS232C ‫ݢ‬େ ᄲख˖CB-ST-
E1MW050-EB ˄ࡒ༥቙৓ི঩๢਋
IA-101-X-MW˅
5m
Ꭱ४‫ݢ‬େ˄‫د‬ጐ P424˅ Ȕᄲख˖CB-SEL-SJ002ȕ ˄ᅤჵ˅
1m
USB ‫ݢ‬େ˄‫د‬ጐ P424˅ Ȕᄲख˖CB-SEL-USB010ȕ ˄ࡒ༥቙৓ི঩๢਋ IA-101-X-USB˅
ə1 ፺ࣙࢆ໢ˈ‫؜‬ᅍᇋ‫ ݕ‬2 ፺೗๒ȃ
I/O ፯୥ I/O ‫ݢ‬େܿ٣‫ݢ ޡ‬ኑ‫ݢ‬ᅼ
C ‫׭‬Ꮃᄲ
1 1 ፺ࣙࢆ 2 2 ፺ࣙࢆ
20 20W པ࠵మ‫ ܌‬200 200W པ࠵మ‫܌‬ 30D RCS2 ቂ 30W པ࠵మ‫ ܌‬300 300W པ࠵మ‫܌‬ 30R RS ቂ 30W པ࠵మ‫ ܌‬400 400W པ࠵మ‫܌‬ 60 60W པ࠵మ‫ ܌‬600 600W པ࠵మ‫܌‬ 100 100W པ࠵మ‫ ܌‬750 750W པ࠵మ‫܌‬ 150 150W པ࠵మ‫܌‬

八合一卫星接收机说明书

八合一卫星接收机说明书

八合一卫星接收机使用说明书目录1安全注意事项 (1)2概述 (2)2.1产品功能及用途 (2)2.2外形尺寸(1U机箱) (2)3主要特点 (2)4技术规格与指标 (3)4.1数据输入 (3)4.1.1射频接口 (3)4.2数据输出 (4)4.2.1ASI接口 (4)4.3网络管理接口 (4)4.4辐射及安全要求 (4)5系统组成及工作原理 (4)5.1系统组成 (4)5.2工作原理 (6)6安装指南 (6)6.1安装准备 (6)6.2设备安装流程 (7)6.3环境条件要求 (7)6.4接地要求 (8)6.4.1机柜接地 (8)6.4.2设备接地 (8)6.5线缆的连接 (8)6.5.1电源线的连接 (8)6.5.2信号线的连接 (9)7前面板操作指南 (9)7.1键盘功能 (9)7.2菜单选择 (9)7.2.1锁定状态显示 (9)7.2.2按EXIT键进入主菜单 (10)7.2.3射频设置 (10)7.2.4输入信息设置 (11)7.2.5输出设置 (12)7.2.6网络设置 (12)7.2.7保存当前设置 (13)7.2.8加载设置 (13)7.2.9版本号 (14)7.2.10选择语言种类(中文和英文) (14)7.2.11错误信息 (14)7.3系统运行错误及排除 (15)7.3.1指示灯状态 (15)7.3.2常见故障排除 (15)8网络管理器操作指南 (16)8.1NMS登陆 (16)8.2添加频点 (18)8.3添加设备 (18)8.4修改设备 (19)8.5查看和设置设备参数 (22)8.5.1基本参数 (23)8.5.2NIT编辑 (24)8.5.3PSI编辑 (25)8.5.4PID透传 (27)8.5.5PID过滤 (28)8.5.6卫星参数 (29)8.5.7信号监测 (30)8.5.8实时监测 (30)8.6网管软件公共功能 (31)前言感谢您选用本公司的产品。

本手册详细介绍了产品的性能、安装及操作方法,无论您是第一次使用该产品,还是以前接触过很多类似产品,都必须在使用前仔细阅读本手册。

LT280最新说明书 2

LT280最新说明书 2

LT280系列开关柜智能微机保护单元使用说明书西安绿泰电子科技有限公司LT280系列微机保护测控装置是多年实践应用和运行经验上,吸取国内外微机保护装置现有的先进技术。

听取国内资深继电保护专家与电力自动化系统人员意见,结合中国电网运行特点和客户要求而自主研发推出的新一代微机保护测控装置,被广泛应用于电力、水利、石油、化工等行业35KV及以下电压等级系列。

作为各种电气设备的主保护或后备保护。

LT280系列装置针对不同需求客户而设计,装置具有保护.测控.通迅功能.整合了第一代微机保护装置.微机测控装置.微机操作箱功能.更加有利于国家电网自动化进程的要求,同时装置通迅功能可服务于电力自动化系统,变电站自动化系统.变配点自动化系统,完全实现了国家电网对自动化系统的要求.本装置保护功能全面可用于架空线路.电缆线路.变压器.电动机.电容器等电气一次设备的保护.在技术上继电保护满足选择性、速动性、灵敏性和可靠性四个要求。

一、装置型号定义LT280系列保护测控装置LT280-01 线路保护测控装置LT280-02 母线综合测控装置LT280-03 线路备自投保护测控装置LT280-04 变压器保护测控装置LT280-05 电动机保护测控装置LT280-06 电容器保护测控装置二、状态指示状态指示灯状态及数量与保护装置类型有关,各灯指示表示功能定义如下:序号指示灯意义颜色1 “运行”微机运行自检灯:装置正常运行时,此灯闪烁,若装置硬件或软件不正常,此灯常亮或常灭。

绿色2 “合位”微机合位指示灯:断路器合位时,此灯亮。

红色3 “分位”微机分位指示灯:断路器分位时,此灯亮。

绿色4 “动作”微机跳闸动作灯:装置正常运行时,此灯熄灭;跳闸类保护动作(发生断路器动作)后,此灯长亮;只有人为复归,此灯熄灭红色5 “告警”微机非跳闸动作灯:装置正常运行时,此灯熄灭;告警类保护动作(不发生断路器动作)后,此灯长亮;只有人为复归,此灯熄灭黄色6 “通讯”微机通迅自检灯:装置通过RS485进行远程通讯时此灯闪烁。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

SC-280同步控制器使用手册一.主要特点与功能SC-280为本公司成熟产品,经过多年的工业现场考验和不断完善,功能实用,抗干扰能力强,稳定可靠。

具有如下特点:该设备由八个单元组成,一路内部主给定,二路外部主给定,八路外部反馈给定,反馈采用±5V内部电源。

内部主给定G0可采用UP、DOWN键调整。

双CPU,10位AD芯片,体积小,功耗低。

二.端子说明(参阅图1):1#:R/S 启动控制端。

2#:ERR 外部故障输入端。

3#:UP 升速端子4#:DOWN 降速端子。

5#:GND 控制信号地。

6#:+10V 外部主给定电源。

7#:GND 外部主给定1地。

8#:G1 外部主给定1输入端(有电压和电流两种给定方式)。

9#:G2 外部主给定2输入端(只有电压给定方式)。

10#:GND 外部主给定2地。

11#:+5V +5V反馈给定电源。

12#:-5V -5V反馈给定电源。

13#:GND 外部反馈给定7,8地。

14#:GF8 外部反馈给定8输入端(-5V~+5V)。

15#:GF7 外部反馈给定7输入端(-5V~+5V)。

16#:GND 外部反馈给定5,6地。

17#:GF6 外部反馈给定6输入端(-5V~+5V)。

18#:GF5 外部反馈给定5输入端(-5V~+5V)。

19#:GND 外部反馈给定3,4地。

20#:GF4 外部反馈给定4输入端(-5V~+5V)。

21#:GF3 外部反馈给定3输入端(-5V~+5V)。

22#:GND 外部反馈给定1,2地。

23#:GF2 外部反馈给定2输入端(-5V~+5V)。

24#:GF1 外部反馈给定1输入端(-5V~+5V)。

25#:V 1 第一单元输出端(0~10V)。

26#:GND 第一单元地。

27#:V 2 第二单元输出端(0~10V)。

28#:GND 第二单元地。

29#:V 3 第三单元输出端(0~10V)。

30#:GND 第三单元地。

31#:V 4 第四单元输出端(0~10V)。

32#:GND 第四单元地。

33#:V 5 第五单元输出端(0~10V)。

34#:GND 第五单元地。

35#:V 6 第六单元输出端(0~10V )。

36#:GND 第六单元地。

37#:V 7 第七单元电压输出端(0~10V )。

38#:GND 第七单元地。

39#:V 8 第八单元输出端(0~10V )。

40#:GND 第八单元地。

41#:TB2 继电器J2的输出常闭触点。

42#:TA2 继电器J2的输出公共端。

43#:TC2 继电器J2的输出常开触点。

44#:TB1 继电器J1的输出常闭触点。

45#:TA1 继电器J1的输出公共端。

46#:TC1 继电器J1的输出常开触点。

47#:L 工作电源输入端:AC220V 。

48#:N 工作电源输入端:AC220V 。

三.面板及操作操作面板说明a) 功能键(ENT): 通过该键可读写每个功能码所对应的参数值。

b) 增减键(▲▼): 此两键用于在进行功能设定时增加和减少功能码和参数值的大小。

c) 切换键(SFT): 该键可使系统从参数设置状态退出或实现出错复位。

图1:端子图220V 电源1输出2输出反馈电源d) 显示器: 在运行中可显示各单元的输出值;在功能设定状态可以显示功能码和参数值。

e) 指示灯PWR : 该灯灭,系统断电; 该灯亮,系统上电。

f) 指示灯RUN : 该灯灭,系统停车状态; 该灯亮,系统运行状态。

g) 指示灯ERR : 该灯灭,系统运行正常; 该灯亮,外部故障。

1.2.1.键盘操作说明参数修改及存储如流程图如图2所示。

1.2.2.典型操作举例例1:改变内部给定电压值F34(从出厂设定值5.00V 该为6.00V )a) 按ENT 显示F00;b) 按 键 在显示为F34时放开 键; c) 再按ENT 键 显示电压值为5.00;d) 按 键或 键 直至显示为6.00; e) 按ENT 键 显示F34;如果参数写保护,将显示Err ,再按ENT 键后显示F34,此时F34仍维持原值10.00不变。

f) 按SFT 键返回正常显示:0.00。

例2:设定第二单元的输入源为内部给定G0 显示器显示第一路输入值为0.00 a) 按ENT 显示F00;b) 按 键 在显示为F02时放开 键; c) 再按ENT 键 显示值为9;图2:参数设定参数值参数值参数号参数号 调节状态运行状态d)按 键直至显示为0;e)按ENT键显示F02;如果参数写保护,将显示Err,再按ENT键后显示F02,此时F02仍维持原值9不变。

f)按SFT键返回正常显示:0.00。

例3:设定第二单元的反馈源为无反馈输入显示器显示内部给定电压值为5.00a) 按ENT 显示F00;b) 按 键在显示为F10时放开 键;c) 再按ENT键显示值为2;d)按 键直至显示为F;e)按ENT键显示F10;如果参数写保护,将显示Err,再按ENT键后显示F10,此时F10仍维持原值2不变。

f)按SFT键返回正常显示:5.00。

例4:设定正常状态显示内容为第二单元输入值S2:a) 按ENT 显示F00;b) 按 键在显示为F38时放开 键;c) 再按ENT键显示值为9;d)按 键直至显示为10;e)按ENT键显示F38;如果参数写保护,将显示Err,再按ENT键后显示F02,此时F02仍维持原值9不变。

f)按SFT键返回正常显示:5.00。

(显示内部给定电压值)四.结构说明图3:系统的组成系统由以下部分组成(参阅图3):1.4.1电源部分把220V 交流电变换成以下直流电源: ±5V/200mA ;+10V/10mA 。

1.4.2主给定部分本调节器内部设有三种独立主给定源,用户可根据需要任意选用。

内部主给定G0: 内部主给定G0的范围是0.00~10.00,分辨率为0.01。

同步控制器上电时功能码F34的值赋给G0,或者说G0的开机初始值等于F34,在启动运行时将按F43设定赋值G0。

使用UP 、DOWN 端子后,G0变化,变化后的G0值在同步控制器失电后丢失,在下次开机时依然用F34值初始化。

F34作为参数不会随UP 、DOWN 端子的操作而变化。

F34必须通过参数设置方式进行设置,F34可断电保持。

F34参数设置成功后将立即赋值给G0。

外部给定—G1:外部给定一由G1端子输入,给定输入方式可有两种: 0~10VDC 和4~20mA ;这两种给定方式可通过功能码F33进行选择。

外部给定二G2:外部给定二由G2端子输入,为0~10VDC 信号。

1.4.3主给定上下限处理(导布速功能):Gi’=G 下限 当Gi< G 下限Gi’=Gi 当 G 下限<Gi<G 上限 Gi’=G 上限 当 Gi>G 上限经过主给定上下限处理后,Gi’受到给定下限、给定上限的限制。

1.4.4速度上升下降时间处理:经过速度上升下降时间处理后,Gi’的变化斜率受到升速斜率(10.00/T UP )、降速斜率(10.00/T DOWN )的限制。

1.4.5信号分配器:信号分配器用于指定各单元输入源。

Si ∈[G0,G1,G2,V1,V2,V3,V4,V5,V6,V7,V8];本单元的输出除外。

Fi ∈[GF1,GF2,GF3,GF4,GF5,GF6,GF7,GF8]1.4.6单元部分本调节器内部包含八个独立单元。

其功能说明如下: Vi=Si*KSi+Fi*KFi 式中:1) Vi 为第i 单元的输出,范围:0~10V2) Si 为第i 单元的单元给定,输入源由功能码选择3) KSi 为单元i 的给定比例,由功能码设定(范围:0.00~15.00) 4) Fi 为单元i 的反馈给定,输入源由功能码选择5) KFi 为单元i 的反馈比例,由功能码设定(范围:0.00~15.00)1.4.7输入输出部分1) RS 端子为运行控制端。

当该端子与GND 短接时,调节器运行,继电器J1动作, 同时点亮RUN 。

运行时显示器的显示由功能码F34决定。

2) ERR 端子为故障信号输入端,当该端子与GND 端短接时,系统认为有外部故障,停止运行,继电器J2动作,显示器显示Err1字样,同时点亮灯ERR 。

3) UP 端子为升速端子,当该端子与1#(或5#)端(GS )短接时,G0增加。

4) DOWN 端子为减速端子,当该端子与1#(或5#)端(GS )短接时,G0减小。

注:UP 、DOWN 可并接多个非自锁按钮,从而实现多点调速。

五.参数表FXX 功能 说明出厂设定 00 退出功能设定状态01 第一单元给定源 9 02 第二单元给定源 9 03第三单元给定源0:给定源为内部主给定1~8:给定源为1~8单元输出(本单元除外) 904 第四单元给定源 9 05 第五单元给定源 9 06 第六单元给定源 9 07 第七单元给定源 9 08 第八单元给定源 9:给定源为外部主给定一 10:给定源为外部主给定二 F :该单元不使用,单元输出为零9 09 第一单元反馈源 F 10 第二单元反馈源 2 11 第三单元反馈源 312 第四单元反馈源 413 第五单元反馈源 514 第六单元反馈源 6 15 第七单元反馈源 7 16 第八单元反馈源 1~8:反馈源为外部反馈给定1~8 F :该路无反馈输入 8 17 第一单元给定比例 1.00 18 第二单元给定比例 1.00 19 第三单元给定比例 1.0020 第四单元给定比例 1.00 21 第五单元给定比例 1.0022 第六单元给定比例 1.00 23 第七单元给定比例 1.00 24 第八单元给定比例 比例的范围:0.00~15.00 (精确到小数点后两位) 1.00 25 第一单元反馈比例 0.20 26 第二单元反馈比例 0.20 27 第三单元反馈比例 0.2028 第四单元反馈比例 0.20 29 第五单元反馈比例 0.2030 第六单元反馈比例 0.20 31 第七单元反馈比例 0.20 32 第八单元反馈比例 比例的范围:0.00~15.00 (精确到小数点后两位) 0.2033 外部主给定一输入方式选择0:电流输入;1:电压输入 1 范围:0.00~10.00(伏)(若输入大于10V ,则按输34 内部主给定值 入为10V 处理) 5.00 35 速度上升时间 范围:0~100(秒) 10 (若输入大于100秒,则按36 速度下降时间 100秒处理) 1037 显示比例系数 范围:0.01-15.00 1.00 38 正常状态显示内容的选择0:运行时,显示run 停车时,显示scd1-8: 显示1-8单元输出值 9-16:显示1-8单元输入值 939 初始化操作 !按ENT 键则参数恢复出厂值 0:可对参数进行修改40参数锁定1:参数锁定(不能修改)41 给定上限 范围:0.00-10.00 10.00 42 给定下限 范围:0.00-10.00 0.00 43 内部给定方式设定 范围:0,1 0 44 升速降速输入端灵敏度设定0.01最慢,4.00最快 0.2六.参数详细说明1.F00 进入、退出功能设定状态工作状态下:按下‘ENT ’键,显示器显示‘F00’,进入参数设定状态。

相关文档