MPR Detector
医院飞利浦BrillianceiCT临床科研型配置方案

医院飞利浦Brilliance iCT临床科研型配置方案敬致:重庆医科大学附属第一医院飞利浦Brilliance iCT 配置方案Philips Healthcare飞利浦医疗保健2013年1月1Brilliance iCT临床科研型配置摘要一 Brilliance iCT主机系统1 Gantry机架系统, Scan Control Panel扫描控制面板, Scan Control Box (ScanTools)扫描控制盒, Integrated Digital ECG & LCD Display一体化LCD显示心电波形, Breathing Lights呼吸指示灯, AutoVoice (ScanTools)自动录音功能, Multi-lingual AutoVoice多语言自动语音功能2 X-Ray system X-线系统, Generator高压发生器, iMRC X-ray TubeiMRC金属陶瓷球管3 Detector探测器, Nano-Panel detector technology(80mm)80毫米纳米探测器技术, Material: Solid State - High Performance Multislice Ceramic 材料:固态-高性能多层稀土陶瓷, Slip Ring: 5.28 Gbps transfer rate滑环传输: 5.28 Gbps 传输速率4 Table检查床, Table扫描床, Table Accessories扫描床附件5 Scan Parameter扫描参数, 256 Slices /Rotation(Smart Focal Spot)256层/圈成像(轴扫、螺旋模式), Scan Times扫描时间20.27,0.30,0.33,0.375,0.40, 0.5, 0.75, 1,1.5秒 /360?, Spiral exposure: Up to 100 sec. of uninterrupted spiral scanning 连续螺旋曝光:最长100秒不间断螺旋扫描, Spiral pitch: 0.07 to 1.0 (user selectable)螺距比用户连续可调: 0.07 到1.06 Image Quality 图像质量, Spatial Resolution :24.0 lp/cm @ cut-off空间分辨率:24线对/厘米, Low Contrast Resolution: 4.0 mm @ 0.3% as measured on the 20 cm CATPHANphantom低密度分辨率:4.0 mm @ 0.3% , (20 cm CATPHAN水模)7 Dose Management剂量管理, DoseRight ACS (Automatic Current Selection)自动毫安选择功能, DoseRight DDOM (Dynamic Dose Modulation)动态剂量调制(轴向), DoseRight ZDOM (Dynamic Dose Modulation)动态剂量调制(纵向), DoseRight Cardiac (Dynamic Dose Modulation) 心电动态剂量调制, Eclipse DoseRight Collimator自动纵向束光准直器, Dose Displays剂量显示, Dedicated Pediatric Protocols婴幼儿专用扫描软件包8 Console Computer 主控制台计算机系统, console Computer主控制计算机, Dual Monitor双显示器, Image Management and Archiving图像管理和存档, Networking/Connectivity网络/联接, DICOM ConnectivityDICOM 联接9 Brilliance Workspace 工作空间CT User Environment 用户环境Guided Flow 引导化的工作流3Patient handling and setup 患者准备和设定 Scan Planning 扫描计划Expert Protocol Planning 专家型方案计划 Preset Post-processing 预设的后处理Manual Scan 手动扫描Automatic Scan自动扫描Productivity Tools 高效率工具QuickStart 快速启动功能QuickSetup 快速设定功能Scan Tools Pro 超级扫描增强配置DICOM Modality Worklist DICOM工作列表管理Spiral Auto Start (SAS) 自动螺旋启动技术(SAS)Prefetch Study 图像自动搜索传送软件Automatic Procedure Selection 自动扫描程序选择软件Split Study 自动病例分发Image Processing 图像处理功能Image Graphics 图像标注,测量分析功能 Window Control 窗宽窗位控制功能10 Clinical Application 通用型临床应用软件Multiple Planar Reconstruction ( MPR)多平面重建 Maximum or Minimum Intensity Projection (MIP) 最大和最小密度投影3-D SSD Reconstruction 三维重建软件包 Volume Rendering 容积三维重建Endo -3D 容积仿真内窥镜SlabViewer 薄块浏览TMMasterCut 智能循迹切割RelateSlice 自动层面相关显示Masterlook 图像智能优化显示软件Small Volume Analysis 小节结分析软件CT Time Lapse CT时间密度曲线图Test Injection Bolus Timing 造影剂注射试验软件 Combine Images 组合图像软件Bolus Tracking 造影剂自动注射智能跟踪软件 Metal artifact reducing software 去金属伪影技术软件 Dedicated Low Dose Lung Protocols 低剂量肺扫描技术 Quantitative CT Measurement Tool 血管定量分析测量软件 Evolving Reconstruction 实时同步重建二 Advanced Clinical Application高级专业型临床应用软硬件1 R R CV Toolkit高级心脏成像软件包DoseRight? Cardiac4心电门控检查剂量调制软硬件Retrospective Tagging回顾性心电门控重建Prospective Gating前瞻性心电门控采集Integrated ECGMonitor 多功能监护仪COBRA? Adaptive Multi-cycle Reconstruction (Cobra Cardiac)三维锥形束自动多周期重建2 Calcium Scoring 冠状动脉钙化评估分析软件3 Cardiac Viewer 心脏评估软件IntelliSpace Portal 星云太空工作站诊断系统 4- Dell Power Edge服务器- 全面独立工作站临床软件应用- 支持5套太空诊断工作站同时运行高级应用Multi - Client Workstation 1 第1太空诊断工作站Multi - Client Workstation 2 第2太空诊断工作站Multi - Client Workstation 3 第3太空诊断工作站Multi - Client Workstation 4 第4太空诊断工作站Multi - Client Workstation 5 第5太空诊断工作站三 Advanced Clinical Application飞利浦独有高级研究功能1 CT COMP CARDIAC ANALYSIS星云太空工作站全息心脏分析软件包2 ECG Editing心电编辑软件Globe View 3心脏冠脉球形显示成像软件3D Map and 2D Map 4心脏冠脉三维地图和二维地图软件5 Magic Glass冠脉魔镜显示软件6 Intravascular Ultrasound (IVUS) 仿真血管内超声显示软件57 Step & Shoot Complete完整心胸门控低剂量体检筛查成像8 Ultra High Resolution Matrices 超高分辨率成像技术9 VIP FunctionVIP立体视觉成像软件10 CT Viewer多功能诊断软件包11 CT AVA STENOSIS星云太空工作站高级血管狭窄分析软件12 CT ADVANCED BRAIN PREF星云太空工作站高级脑灌注分析软件13 CT BODY PERFUSION星云太空工作站体部灌注分析软件14 Liver Perfusion肝脏双血流灌注软件四附件1 COMPUTER TABLE主台计算机操作台2 Console UPS (30 min)主台计算机不间断电源(30分钟)五选件部分(独有配置不含设备总报价中,单独报价)41 星光iDose4 iDose, an output of Philips' DoseWise philosophy, is an advanced fourth generationiterative reconstruction technique designed to maintain critical image qualityaspects of low-contrast detectability and spatial resolution while enabling4dramatically lower dose levels. iDose complements other proven dose reductiontechniques available on Philips CT scanners to improve image quality and / or lowerradiation dose acquisitions beyond those previously achievable throughconventional filtered back-projection techniques.4星光iDose源于飞利浦智能剂量调制技术体系,这是一种以迭代重建技术为特征的第四代6影像重建技术。
GErevolution 256排螺旋CT用户手册_3

• 层厚选择范围为 0.625 至 5.0 mm。
• 用于决定机架每转一周扫描床的速度的螺距、探测器覆盖范围和旋转时间。有两个的螺距选项
(具有相关扫描床速度)。
• Rotation Time(旋转时间)决定机架旋转 360° 的速度。
章 8 设备
203
Revolution™ CT, Revolution™ CT ES 用户手册 指令 5763054-1ZH-CN, 修订版 1
7.2 覆盖范围
轴向探测器覆盖范围/射束准直:
• 512 层系统具有 5、40、80、100、120、140 和 160 mm 的射束准直/探测器覆盖范围 (0.625
mm)。
• 256 层系统具有 5、40 和 80 mm 的射束准直/探测器覆盖范围 (0.625 mm)。
表 22: 每转产生的图像
有助于从腹部和下肢的 CT 血管造影 (CTA) 检查中去除骨骼并移除 CT 扫描 床。
提供增强的血管功能分析,其中包括狭窄分析、预备/后期支架计划程序以 及定向血管弯曲的可视化。
提供全面的软件包,用于快速、准确、无创性结肠检查的评价。
心血管和电生理成像应用程序的后期处理图像分析软件。
为重新格式化、3D 绘制和容积绘制提供协议。
• 旋转时间能够调整,从而可优化采集时间。旋转时间是 0.28、0.35、0.5、0.6、0.7、0.8、0.9
和 1.0 秒。
204
7 硬件组件
Revolution™ CT, Revolution™ CT ES 用户手册 指令 5763054-1ZH-CN, 修订版 1
8 配电系统
配电系统 (PDU) 为系统的各部件供电,包括机架部件、扫描床和操作员控制台。PDU 正面有指示 电源开启状态的控件、打开/关闭机架和扫描床电源的按钮,以及 Emergency Stop(紧急停止)按 钮。
冠状动脉CTA双期扫描在非瓣膜性房颤患者左心耳血栓筛查中的应用研究

心房颤动(房颤)所致的心源性血栓是缺血性脑卒中发病的主要危险因素,其中非瓣膜性房颤患者的血栓90%以上来自左心耳[1]。
因此,左心耳血栓的筛查、及时干预对预防脑卒中不良事件发生有重要的临床意义。
目前,经食管超声心动图(trans -esophagealechocardiography ,TEE )是左心耳血栓检测的金标准[2],但其为有创检查,部分患者无法耐受,且对操作者的经验依赖性较强[3]。
常规冠状动脉CTA (CCTA )是一种无创的检查技术,房颤患者左心耳代偿性扩大致血液淤滞排空能力下降,可造成左心耳血栓假阳性结果[4],而双期扫描增加了左心耳的充盈时间,能大幅提高左心耳的充盈及显示。
本研究采用320层CT 设备,利用其宽探测器、超高空间及时间分辨率优势,评估双期扫描筛查诊断非瓣膜性房颤患者左心耳血栓的价值,并探讨左心耳血栓发生的危险因素。
DOI :10.3969/j.issn.1672-0512.2023.02.010[基金项目]上海市卫健委智慧影像重点实验室、上海市嘉定区医学重点专科(2020-jdyxzdzk -02);上海市嘉定区卫生健康委科研项目(2021-KY -02)。
[通信作者]梁凯轶,Email :。
冠状动脉CTA 双期扫描在非瓣膜性房颤患者左心耳血栓筛查中的应用研究李春晨,尹小花,程韬,梁凯轶上海健康医学院附属嘉定区中心医院放射科,上海201800[摘要]目的:使用联影宽探测器UCT960320层CT 行冠状动脉CTA (CCTA )双期扫描,探讨CCTA 双期扫描在非瓣膜性心房颤动(房颤)患者左心耳血栓筛查中的应用价值。
方法:选取拟行心脏射频消融术或左心耳封堵术的109例非瓣膜性房颤患者,行CCTA 双期扫描及经食管超声心动图(TEE )检查;将CT 原始图像传入后处理工作站,行MIP 、MPR 、VR 等后处理,观察左心耳有无血栓;以TEE 检查结果为金标准,评价CCTA 双期扫描对左心耳血栓的诊断效能及与TEE 的一致性。
医学影像 MEDICAL IMAGING

natural contrast
natural contrast
artificial contrast
artificial contrast
Contrast Media
positive contrast media barium sulfate:introduction into gastrointestinal tract organic iodine:(water-soluble) ionic or non-ionic, introduction into blood vessels 、 bile duct,etc inorganic iodine :iodized oil,introduction into bronchia、oviduct,etc negative contrast media : CO2 、O2 、air
reference with clinical history, lab findings and other examinations
Computed Tomography
1969 1972 1979
design be made be produced won Nobel Prizes
G.N. Hounsfield
Special X-ray Examination
tomography: the X-ray tube and the film or the patient move simultaneously in
opposite directions during the exposure
mammography: used in the examination of
Normal X-ray Examination
自由呼吸肺静脉CT造影容积扫描技术的可行性研究

DOI:10.3969/j.issn.l007-5062.2021.06.020•临床论著•自由呼吸肺静脉CT造影容积扫描技术的可行性研究李勐徐磊晏子旭王瑞窦瑞雨朱栓庄常星[摘要]目的:探讨自由呼吸肺静脉容积CT扫描的可行性研究。
方法:选择行肺静脉CT造影者(PCTV)患者140例,随机分为A组常规屏气扫描组70例和B组自由呼吸扫描组70例,比较两组的图像质量、辐射剂量和对比剂用量。
结果:两组测量区平均CT值、信噪比之间差异无统计学意义,主观图像质量评分差异无统计学意义(P=1.152);辐射剂量(P=0.482)和对比剂用量(P=0.585)比较,差异无统计学意义。
结论:采用宽体探测器CT前瞻性心电门控容积扫描模式,在自由呼吸状态下PCTV具有可行性。
[关键词]心房颤动;肺静脉;X线计算机;体层摄影术;左心耳血栓[中图分类号]R54[文献标志码]A[文章编号]1007・5062(2021)06・611・04Feasibility study of pulmonary CT venography volume scanning with free breathing LI Meng,XULei,YAN Zixu,WANG Rui DOU Ruiyu,ZHU Shuanzhuang,CHANG Xing,Department of Radiology,Beijing,Beijing Anzhen Hospital,Capital Medical University,Beijing Institute of Heart,Lung and Blood VesselDiseases,100029Beijing,China[Abstract]Objective:To explore the feasibility of free-breathing CT pulmonary venography using pro-spective-ECG gating volume CT.Methods:One hundred and forty patients planning to CT pulmonary venography(CTPV)were randomly divided into two groups,Group A(70cases)and Group B(70cases).The imagequality,radiation dose and contrast agent dosage of the two groups were compared.Results:There was no significant difference between the two groups in average CT value,signal to noise ratio(SNR),subjective imagequality score(P=1.152),radiation dose(P=0.482)and contrast dose(P=0.585).Conclusions:The freebreathing CTPV is feasible using wide-body volume CT with prospective-ECG gated.[Keywords]Atria fibrillation;Pulmonary vein;X-ray computed;Tomography;Left atrialappendage thrombosis肺静脉CT造影(CT pulmonary venography,CTPV)是应用于心房颤动(atrial fibrillation,AF)患者的一项常规影像学检查技术[1]o可以术前明确肺静脉开口位置、左心房解剖形态和变异情况、左心耳部有无血栓形成[2-3]。
心脏冠状动脉多排CT临床应用专家共识

关键字:心脏冠状动脉多排CT MDCT《中华放射学杂志》2011年首刊发表了“心脏冠状动脉多排CT临床应用专家共识:中华放射学杂志心脏冠状动脉多排CT临床应用协作组(中华放射学杂志2011;45(1):9-17.)”,这是我国第一个有关冠状动脉CT血管成像的专家共识。
该共识发表的背景是:多排CT(multi-detector computed tomography,MDCT)5年来积累了一定的应用经验和循证医学证据;美国放射学院(ACR)于2006年就心脏CT应用和诊断发表了指南,美国心血管CT协会(SCCT)在2009年发布了类似指南,2010年,美国心脏协会(AHA)和美国心脏病学院(ACC)分别在其学会期刊Circulation和JACC上发表了冠状动脉CTA专家共识。
另外,对于MDCT心脏冠状动脉检查适应证、应用价值和限度等方面的认识,放射科医师与临床医师(特别是心内科医师)有必要加强沟通和经验交流,利用设备解决好临床问题。
但该共识是基于64排CT为基础写的,没有“后64排”CT的内容。
(一)心脏冠状动脉CT应用基本要求1.对医师能力的要求(1)熟悉CT物理学和成像原理,强调对辐射和曝光知识的掌握;(2)熟悉心脏和冠状动脉MDCT扫描参数、重建参数和后处理技术;(3)熟悉心脏CT对比剂最佳注射方案、安全性、禁忌证、不良反应处理和碘过敏反应的治疗;(4)熟悉心脏CT使用其他药物(如β受体阻滞剂、硝酸甘油)的适应证和禁忌证及其处理;(5)具备冠心病和其他心血管病(包括各种先天性和获得性心血管病)的相应临床和病理生理改变的知识;(6)掌握心脏、冠状动脉、冠状静脉、肺动脉和肺静脉等解剖;(7)掌握常见胸部、纵隔和腹部疾病的CT诊断基本知识;(8)具备基本的ECG诊断和心律失常诊断的知识。
2.对医师培训的要求放射科医师独立从事心脏CT临床诊断工作,必须具有执业医师资格和大型设备上岗证(CT);必须了解心脏冠状动脉检查适应证;接受不同等级的培训(表4-10-2),其中中级和高级水平以上方可独立操作和书写诊断报告。
256层螺旋CT前、后置心电门控技术对冠脉成像质量及辐射剂量的影响
256层螺旋CT前、后置心电门控技术对冠脉成像质量及辐射剂量的影响黄丙军【期刊名称】《《中国CT和MRI杂志》》【年(卷),期】2017(015)006【总页数】3页(P34-36)【关键词】256层螺旋CT; 心电门控技术; 冠脉成像质量【作者】黄丙军【作者单位】南方医科大学附属小榄医院放射科广东中山528415【正文语种】中文【中图分类】R331.3+8256层螺旋CT冠脉动脉成像因其无创、成功率高、成像质量好等优点在冠状动脉疾病诊断中应用较多,但实际工作中256层螺旋CT检查会产生一定的辐射量,可能给人体带来伤害。
心电门控技术不仅关系到多层螺旋CT冠脉成像质量,而且不同心电门控技术所产生的辐射剂量大小不一[1]。
目前临床常见心电门控技术包括回顾性心电门控(即后门控)与前瞻性心电门控(即前门控),其中前者通常扫描时间相对长,可能增加辐射剂量,而后者对R波时间可事先预测,且采取非螺旋方式采集图像能缩短扫描时间[2]。
为此本文基于保证多层螺旋CT冠脉成像质量外最大限度减少辐射剂量目标,对我院2013年1月~2015年12月疑诊为冠状动脉疾病患者行256层螺旋CT前门控、后门控技术图像资料进行回顾性分析,现报告如下。
1.1 临床资料抽取我院2013年1月~2015年12月疑诊为冠状动脉疾病患者70例,纳入标准:①经胸痛等症状临床行多层螺旋CT冠脉成像检查;②检查前控制心率<75次/min;③肝肾功能正常;④患者知情同意,CT冠脉成像图像资料完整。
排除标准:①体重指数(BMI)>30kg/m2;②冠脉支架置入或搭桥治疗史;③严重心律不齐;④碘对比剂过敏者。
随机双盲法将患者分为前门控组(36例)与后门控组(34例),前门控组中男20例,女16例;年龄48~76岁,平均(61.4±10.2)岁;体重4 6~7 8 k g,平均(63.0±6.4)kg。
后门控组中男18例,女16例;年龄46~77岁,平均(61.7±10.0)岁;体重47~80kg,平均(63.2±6.8)kg。
GE 64排CT技术指标
Product Data Sheet – Rev 1.1 January 6, 2005 Page 1
LightSpeed VCT
Voam FX
GE Healthcare Milwaukee, USA - Fax: 1 262 544 3384 Tokyo, Japan - Fax: 81 425 85 5490 Paris, France - Fax: 33 1 30 70 94 35
- GE Proprietary HiLight™ scintillator that provides fast, repeatable light output
g
Product Data Sheet – Rev 1.1 January 6, 2005 Page 2 • The Power to Perform: The 100 kW, 800mA Performix™ Pro 100 X-Ray Tube demonstrates the highest reliability and delivers the highest power you need for image quality at fast rotation speeds and for large patients. • New XtreamTM FX technology breaks through existing limits on speed, image quality and flexibility to provide an optimized volumetric workflow solution from acquisition to final report. At the core of Xtream FX is a new operator’s console that delivers up to 16 frames per second reconstruction at full resolution for any slice thickness, even with GE’s volumetric reconstruction algorithm on, that is matched to the industry’s highest 16 frames per second transfer rate. Xtream FX is a fieldupgradeable, inherently scalable platform designed with the future in mind. - Direct MPR enables automated protocol-driven axial, sagittal, and coronal reformats. Reformatted images may be routed to multiple network destinations, eliminating the need to transfer and store all thin-slice data. - Exam Split* allows multi-anatomic exams to be read in separate anatomic sections. This allows specialists to review only those images needed for a given requisition. - ECG Waveform on the Console* will allow users to visualize the ECG waveform directly on the CT scanner console during the scan. The waveform data can be viewed to determine where prospectively-created images are located with respect to the heart cycle to better understand motion artifacts like blurring or mis-registration. - Data Export is a stand-alone tool to convert clinical images into PC-friendly formats like .jpeg, .mpeg, and .avi from the image browser, creating more flexible report creation for both referring physicians and patients. Images can then be saved using Data Export tool to any PC industry standard removable media, including CD-ROM and DVD. - 803 GB disk (system, image, scan disks) stores up to 250,000 5122 images and 3,369 scan rotation data files. • Fully 3D Volumetric Reconstruction. True cone beam reconstruction combined with true 64x0.625mm acquisition reduces artifacts from z-interpolation. All scan modes can take advantage of the image quality benefits from cone beam reconstruction.
胃癌临床分期诊断方法的应用进展
Vol.41No.6Jun.2021上海交通大学学报(医学版)JOURNAL OF SHANGHAI JIAO TONG UNIVERSITY(MEDICAL SCIENCE)胃癌临床分期诊断方法的应用进展马江磊1,李晓瑶1,赵世富1,杨德君21.海军军医大学基础医学院二大队,上海200433;2.海军军医大学附属长征医院胃肠外科,上海200003[摘要]准确的胃癌临床分期对于治疗方案的选择以及预后评估都具有重要的指导意义。
近年来,胃镜、超声内镜、多层螺旋CT、磁共振成像以及正电子发射计算机断层扫描等检查的普及应用为胃癌临床分期提供了重要的客观参考,提高了分期的准确性。
该文就目前临床常用检查方法对于胃癌临床分期诊断价值的研究进展进行综述。
[关键词]胃癌;临床分期;内窥镜;影像学检查[DOI]10.3969/j.issn.1674-8115.2021.06.020[中图分类号]R445.3[文献标志码]AAdvances in diagnostic methods of clinical staging for gastric cancerMA Jiang-lei1,LI Xiao-yao1,ZHAO Shi-fu1,YANG De-jun21.Second Brigade,College of Basic Medical Sciences,Naval Medical University,Shanghai200433,China;2.Department of Gastrointestinal Surgery,Changzheng Hospital, Naval Medical University,Shanghai200003,China[Abstract]Accurate clinical staging of gastric cancer is of great significance for choosing an optimal therapeutic schedule and evaluating the prognosis.In recent years,objective evidences have been provided owing to the use of diagnostic methods such as gastroscopy,endoscopic ultrasound,multi-detector row computed tomography,magnetic resonance imaging and positron emission tomography-computed tomography,which have greatly enhanced the accuracy of clinical staging diagnosis for gastric cancer.This paper reviews the research progress in current clinical examining techniques for clinical staging diagnosis.[Key words]gastric cancer;clinical staging;endoscopy;imaging胃癌是世界上常见的恶性肿瘤,也是我国最常见的上消化道恶性肿瘤[1-3]。
256层多排螺旋CT小肠成像对小肠炎症性病变的临床应用研究
第22卷 第2期 CT理论与应用研究 Vol.22, No.2 2013年4月(329-338) CT Theory and Applications Apr., 2013解骞, 窦娅芳, 梁宗辉, 等. 256层多排螺旋CT小肠成像对小肠炎症性病变的临床应用研究[J]. CT理论与应用研究, 2013, 22(2): 329-338.Xie Q, Dou YF, Liang ZH, et al. Application of 256 multi-detector computed tomography enterography in small bowel inflammatory diseases[J]. CT Theory and Applications, 2013, 22(2): 329-338.256层多排螺旋CT小肠成像对小肠炎症性病变的临床应用研究解骞1,窦娅芳2,梁宗辉3 ,朱全东1,祝瑞江11.复旦大学附属华山医院放射科,上海2000402.上海交通大学附属第一人民医院放射科,上海2000803.上海市静安区中心医院放射科,上海200040摘要:目的:探讨256层多排螺旋CT小肠造影(MDCTE)扫描技术在小肠炎症性病变诊断中的临床应用价值。
材料和方法:对118例临床怀疑小肠疾病患者(男53例,女65例,平均年龄48.5岁)行256-MDCTE平扫及增强扫描,通过横断面及多平面重建,观察病变部位、大小、形态、周围情况等与病理结果对照分析。
结果:本组118例患者中,小肠炎症性病变25例(男13例,女12例,平均年龄45.5岁),其中Crohn病12例(因克隆恩病肠壁增厚引起不全性小肠梗阻1例),溃疡性结肠炎2例,小肠结核1例,病毒性肠炎1例,小肠黏膜一般炎症7例,另外2例临床无法确诊。
MDCTE诊断21例,4例漏诊者均为一般炎症。
结论:小肠炎症性病变在MDCTE上具有特征性的表现,MDCTE能全景式、多方位展示小肠肠道、肠系膜和系膜血管,对小肠炎症性疾病的诊断具有重要价值。